Similar documents
Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

Universal Retrofit System Installation Instructions Revised:

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Instruction/Installation Manual

LED 2/3/4ft T8 Tube 120V

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

Installation Instructions BLTR and 2BLTR Relight Assembly

TECTONIC LED CORP. ISO

Product Installation Instruction LED Tube Lamp Retrofit Kits

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

LED IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit

LED Recessed Troffer Retrofit Kit

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

CFP-LED Contractor Select Flat Panel. Installation Instructions

Optimax Pro Retrofit Instructions

Lumination TM LED Luminaire LUR Series

Assembly Instructions Retrofitting

Redbird LED Cardinal Stripit Kit Installation Instructions

Solid State T8 tube is the smart alternative to a

MAXLITE RKT LED Retrofit Kit

General Installation Instructions LED

T8 Tube Light. UL LISTED & cul LISTED & DLC LISTED. Germany Patent: Gebrauchsmusters / Nr

LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

SAVE THESE INSTRUCTIONS

Motion and Light Sensor Kit LHBAS51

LED IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

LED IMPORTANT SAFETY INSTRUCTIONS

PDX and PX Retrofit Series

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

Installation Instructions: Eco-Fit T8 LED Tube Lamp

LM79 LM80 L70:5+ YEARS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions: ACCENT SYSTEM

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

LED IMPORTANT SAFETY INSTRUCTIONS

LED Security Wallpack Installation Instruction

Installation Instructions: HYPERION R-Lite SYSTEM

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

LED IMPORTANT SAFETY INSTRUCTIONS

Installation Instruction ALG Series LED Area Light Version: 3.1

NOTE: The orientation of the mounting brackets are critical. (See Figure 4)

HPNLS-HO. Installation Manual

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

ECO EXT (DIMMABLE)

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Circa Ambient Interior Luminaire

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

PIL0478 ISSUE 01/ 07/16

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

General Installation Instructions LED

Quick Installation Guide. Affinium LED Modules LFM300 for Refrigerated Display Cases

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

INSTALLATION INSTRUCTIONS

TRUET5 EXT (DIMMABLE)

SURE-LITES FBP140XLP Instruction Manual

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

UL AND CODE COMPLIANCE

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

Installation Instructions: Eco Linear High Bay

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

LED IMPORTANT SAFETY INSTRUCTIONS

INSTRUCTION MANUAL SINKER. By HAY

Installation Guide for EcoBrite EndLite LED Light Fixtures

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

LED Utility Wrap Fixture

TECHNICAL SPECIFICATIONS

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

Installation Instructions

Linear Replacement Lamps

LED. High-performance streetlight. -afortable and reliable

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

Cincinnati, OH USA

Installation Documentation ID-2663

INSTRUCTION MANUAL. All PrimeTime Studio Lights are equipped with advanced reflector technology.

P/N Wheeler. user manual

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

Measurements are expressed in millimeters.

LED UFO High Bay with j-box Installation Instruction

Transcription:

www.greenelectricalsupply.com

1x4 2x2 & 2x4 Read all instructions and warnings before attempting installation. RISK OF FIRE OR ELECTRIC SHOCK. LED RETROFIT INSTALLATION REQUIRES KNOWLEDGE OF LUMINAIRES SYSTEMS. IF NOT QUALIFIED, DO NOT ATTEMPT INSTALLATION. CONTACT A QUALIFIED ELECTRICIAN. RISK OF FIRE OR ELECTRIC SHOCK. INSTALL THIS KIT ONLY IN THE LUMINAIRES THAT HAVE THE CONSTRUCTION FEATURES AND DIMENSIONS SHOWN IN THE PHOTOGRAPHS AND/OR DRAWINGS. TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR OTHER SHARP OBJECTS RISK OF PERSONAL INJURY. THIS EQUIPMENT MAY HAVE SHARP EDGES. WEAR GLOVES TO PREVENT CUTS OR ABRASIONS WHEN REMOVING FROM CARTON, HANDLING AND MAINTAINING THIS EQUIPMENT. DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL COMPONENTS DURING KIT INSTALLATION. RISK OF FIRE OR ELECTRIC SHOCK. INSTALLATION OF THIS RETROFIT ASSEMBLY REQUIRES A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE LUMINAIRE S ELECTRICAL SYSTEM AND THE HAZARD INVOLVED. IF NOT QUALIFIED, DO NOT ATTEMPT INSTALLATION. CONTACT A QUALIFIED ELECTRICIAN. RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION. RISK OF FIRE OR ELECTRIC SHOCK. INSTALLATION OF THIS RETROFIT ASSEMBLY REQUIRES A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE LUMINAIRE S ELECTRICAL SYSTEM AND THE HAZARD INVOLVED. IF NOT QUALIFIED, DO NOT ATTEMPT INSTALLATION. CONTACT A QUALIFIED ELECTRICIAN. ONLY THOSE OPEN HOLES INDICATED IN THE PHOTOGRAPHS AND/OR DRAWINGS MAY BE MADE OR ALTERED AS A RESULT OF KIT INSTALLATION. DO NOT LEAVE ANY OTHER OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL COMPONENTS. *Deco Digital assumes no responsibility for claims arising out of improper orcareless handling or installation of this product.

KIT CONTENTS (PARTS LIST) Deco s s are designed for easy installation. Please reference table to the right to determine your kit contents for your install type. 2 Standard components of a single kit

Installer Notes: 1.) IMPORTANT: During install, be careful not to touch the LEDs, at the risk of damaging them. 2.) When wiring power supply to AC input using the power supply, Green wire attaches to Ground. All other power supplies only have 2 wire AC inputs. 3.) A set of labels with model, serial number, and date of manufacture are included in packaging and must be installed in the luminaire once installation is complete. All of these labels must be applied in compliance with UL standards. 4.) Install requires application of the Luminaire Modification Label provided in your kit, as per UL. This label includes the statement: This fixture has been modified and can no longer operate the originally intended lamp. This label should be applied to troffer housing during installation (Step 17). 5.) Sleeving on jumper wires is not reflected in the wiring drawings. Be sure sleeving is in place where sharp edges from the ballast cover may come in contact with the cable. 6.) IMPORTANT: Placement of kit components should be thought out and determined prior to surface adherence, to ensure that placement of parts reflects cable lengths. 7.) Placement of LINEA-LED Strips in a fixture using a parabolic lens must be carefully determined prior to adherence, so that strips will be placed in the middle of cells to allow maximum light output. Begin Installation 1 2 3 Read all warnings (p. 1) AND Installer Notes (p. 3) before proceeding with retrofit. Check your retrofit kit against parts list (page 2). Disconnect power to fixture. Note: This installation guide pertains to Deco Retrofit Kit install in typical 1 x4, 2 x2, and 2 x4 recessed troffers. Diagrams below show standard fluorescent fixtures (1 x4, 2 x2, and 2 x4 ) prior to retrofit (not showing diffuser cover): 2x2 2x4 1x4 Fluorescent Fixture Examples, Before Retrofit: 3

4 5 6 7 Remove fluorescent tubes (**Dispose of tubes in proper accordance with current state and federal regulation. Fluorescent tubes contain hazardous materials**) Remove ballast cover Cut both wires at ballast to the AC 8 9 lamp holders (sockets) USE CLOTH AND CLEANING SOLUTION TO WIPE DOWN THE SURFACE OF HOUSING THOROUGHLY BE SURE TO REMOVE ALL DUST, GREASE, ETC & DRY BEFORE PROCEEDING Cut the wiring at the lamp holder strips. Do not remove lamp holders. 4

10 Install Power Supply(ies), securing with the screws provided in the kit: Remove cover film from thermal tape on the back of the Power Supply(ies) When determining where to mount driver, consider provided RED/BLACK jumper cable lengths to ensure all components will be within reach. Carefully press Power Supply on surface of luminaire. Use a power drill to secure power supply with screws in holes located on supply(ies) 11 Connect flying leads from power supply to AC Mains connection (from existing housing) according to diagram A below DIAGRAM A AC AC in LED Driver Tie (using wire nuts): Black [AC out - Live] to Brown [AC in] White [AC out - Neutral] to Blue [AC in] Tie (using wire nuts): Green [AC out] to Green [Ground] Input AC Ground 5

12 Connect power supply to connector board. 13 14 15 Re-install ballast cover over connector board and power suppl(ied). Install LINEA-LED Strips : Remove cover film from back of thermal tape Carefully press the LINEA-LED Strips onto mounting surface. BE SURE NOT TO TOUCH LEDS, AT THE RISK OF DAMAGING THEM. For installs into fixtures with a parabolic lens, when possible, carefully align strips so that when troffer is closed, strips will be oriented in the middle of the parabolic lens cells. Secure each individual LED Strip to the housing using 3 screws. Kits should contain 3 screws for each Strip. 16 Connect LED Driver to Dimming Sensor. Run Blue (DIM +) and White (DIM -) wires from LED Driver to 0-10V Dimming Sensor, as per Diagram B on page 7. Run RED/BLACK jumper cables from connector board(s) to Linea-LED. Be sure sleeving is oriented where any sharp edges from the ballast cover may come in contact with the wire. 17 Installer must now adhere Luminaire Modification Label to the fixture. Luminaire Label is included in packaging and reads: This luminaire has been modified and can no longer operate the originally intended lamp. This step is required by UL standards. 6

WIRING Flying Leads Function BLACK (AC out) Live WHITE (AC out) Neutral GREEN Ground BROWN (AC in) Live BLUE (AC in) Neutral RED (DC out) POS (+) BLACK (DC out) NEG (-) INSTRUCTIONS: Power Supply to AC Tie Brown [AC in] to Black [AC out] Tie Blue [AC in] to White [AC out] Tie Red [DC out +] to Red (from Connector Board) Tie Black [DC out - ] to Black (from Connector Board) Tie Copper to Green Tie Green to Ground [screw] Connector Board to the LINEA-LED Strips Snap RED/BLACK jumper cables into ports on connector board Run RED/BLACK jumper cables from board to RTF strips and power supply [DC out], as shown. DC WIRING & DIMMER LEAD SCHEMATIC DIAGRAM B AC in LED DRIVER DC out white (DIM -) red (+) black (-) 0-10V to connector board 7

Wiring Schematic 1x4 2x2 & 2x4 8