GRAMIN BANK OF ARYAVART

Similar documents
(A.Z.KHAN) CHIEF MANAGER

PART B: FINANCIAL BID

M. C. B. / D. B./MCCB : MDS/Schneider/Siemens/havells

B.O.Q's FOR ELECTRICAL WORKS FOR BANK OF INDIA, COLLEGE ROAD, DHAKA BRANCH

Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal.

Section VI: List of Requirements (REVISED)

Supply of Batteries

Tender Schedule. Sl. No. Particulars Quantity Unit Rate `

to UPS outgoing DB. c With 2 nos. 6 Sq.mm + 1 no. 2.5 Sq.mm. PVC insulated copper wire from UPS outgoing DB to CDB / Main panel to LDB /

SCHEDULE OF QUANTITY

TENDER. Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH

Rate (Rs.) in figure. Rate (Rs.) in words. VAT (%) Amount (Rs.) & all other taxes.

BOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH

PART A: FINANCIAL BID

Bill of Quantity for Electrical & Computer wiring works for Shifting of SMECC Jamshedpur to Jamshedpur Branch Premises

Hkkjrh; izca/k lalfkku dksf"kddksm

NOTICE INVITING QUOTATIONS


B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD

REGIONAL MANAGER (VADODARA REGION)

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount

THE ORIENTAL INSURANCE CO.LTD. REGIONAL OFFICE: IDA Building 4 th Floor, 7,Race Course Road, Indore (M.P.) REQUIREMENT

Bills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu.

B.O.Q ELECTRICAL WORK OF CANARA BANK, BUDHARAJA BRANCH

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Technical Specifications

ANNEXURE-I CHECK LIST FOR APPLICATION FORM

Ref. No: 01/Electric/KC/Pc/17 Date: 24/11/2017

TENDER DOCUMENT PART-II

FORMAT B (Annexure-III)

(LAST DATE OF SUBMISSION: ) QUOTATION FOR ANNUAL MAINTENANCE CONTRACT OF SERVERS, COMPUTERS, PRINTERS, NETWORKING AND LAN

FINANCIAL BID NAME OF WORK : ELECTRIFICATION WORK AT THE NEW OFFICE PREMISES OF SBI EXCLUSIF KOZHIKODE BRANCH

RAJIV GANDHI UNIVERSITY OF KNOWLEDGE TECHNOLOGIES BASAR Nirmal District, Telangana Ref: RGUKT-B/Proc/Elec,Maint/Q08/2018, dated

: Material Description Quantity UOM

Amount (Rs) 1.5 sq. mm ISI marked, FR

INDIAN INSTITUTE OF TECHNOLOGY, KANPUR DEPARTMENT OF ELECTRICAL ENGINEERING

FORMAT-III B - ANNEXURE-III

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Supply of 63 kva DIESEL GENERATOR SET WITH AMF

ZONAL OFFICE KEONJHAR ZONE

GUWAHATI MUNICIPAL CORPORATION WATER WORKS :: PANBAZAR GUWAHATI


FORMAT-III B - ANNEXURE-IV

NLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

MAIN INCOMER -1 (500 KVA TRF.)

Guidelines for Registration of Private / Transport Vehicles

STATE BANK OF INDIA ADMINISTRATIVE OFFICE -7 : HUBBALLI KUDRIGE BRANCH - REGION 5, KARNATAKA. ELECTRICAL WORKS : SCHEDULE OF ITEMS(BOQ)

Annexure- II (Price Bid) SCHEDULE B LIST OF ELECTRICAL ITEMS TO BE SUPPLIED

University of Peradeniya INVITATION FOR BIDS

Total Cost Abstract. Project Name : - RDPL, Jaipur. Grand Total

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

045 : 2000 CEB STANDARD

SCHEDULE OF QUANTITIES OF ELECTRICAL WORKS FOR BOI, ZO, JODHPUR. PART - II

ESTIMATE FOR ELECTRICAL WORKS AT CHINCHOLI BRANCH

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

Open Tender Enquiry OUTSOURCING OF PHOTOCOPY WORK AT SCOOTERS INDIA LIMITED SINGLE BID SYSTEM. SCOOTERS INDIA LIMITED Page 1

SPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT /

TECHNICAL SPECIFICATION FOR SUPPLY OF LT DISTRIBUTION KIOSK FOR 250/315 KVA & 63/100 KVA RATING DISTRIBUTION TRANSFORMERS AGAINST TN-2077

Tender for procurement of Passive Components of LAN & Wi-Fi and their installation. Corrigenda. Annexure/Clause For Read

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

sl. No Description Unit Qty Rate (Rs) Amount (Rs)

Tender documents for supply, erection & commissioning of Plante Type Battery to 2x210 MW IB Thermal Power Station.

SPECIFICATIONS OF SINGLE GIRDER UNDER SLUNG E.O.T. CRANE CAPACITY: 5 MT

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

TENDER DOCUMENTS SUPPLY OF ELECTRICAL EQUIPMENT FOR BHADRAK MUNICIPALITY FOR THE YEAR LAST DATE OF RECEIVED OF TENDER DOCUMENTS :

Inviting Tenders for Supply, Installation, Testing and Commissioning of 500 KVA DG Set for Temperature Controlled Warehouse at Medchal, Hyderabad.

Regional Office: Vijayapura Plot No6, Trimurthy Nagar Managuli Bypass Road, Vijayapura Diesel Generator Required on Rental Basis

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.

File No. EL/EE/NAD/Tech/1-13/2018/822 Dated: 29/08/2018 OFFICE OF THE EXECUTIVE ENGINEER NORTH ANDAMAN DIVISION ELECTRICITY DEPARTMENT DIGLIPUR

Net +Plus Connection Code

SCHEDULE OF QUANTITIES FOR THE ELECTRIFICATION STRUCTURED / DATA CABLING WORKS FOR THE FEDERAL BANK'S

SAVE ENERGY FOR BENEFIT OF SELF AND NATION

Pre-Qualification- Cum Bid Notice

SBI INFRA MANAGEMENT SOLUTIONS PVT.LTD. CIRCLE OFFICE, AHMEDABAD STATE BANK OF INDIA, RBO-II, C.N. VIDYALAYA CAMPUS, AMBAWADI, AHMEDABAD

Supply, Installation and Commissioning of 1 No 50 Watt LED. based SPV SLS at Nadia District Library, Krishna Nagar, Nadia.

SECTION 1 SCOPE, SPECIFIC TECHNICAL REQUIREMENT AND QUANTITIES

Estimate For Electrical Works PROPOSED RUDSET INSTITUTE AT BERHAMPUR

RMS CONDITIONAL REGISTRATION SCHEME HISTORIC (CRS-H) RULES FOR MEMBERS. Mustang Owners Club Australia (N S W) Inc.

Corrigendum-I. Bill of Quantity

BANGALORE ELECTRICITY SUPPLY COMPANY LIMITED

TENDER DOCUMENTS FOR ELECTRICAL WORKS STATE BANK OF INDIA

FORM 20 [See Rule 47] APPLICATION FOR REGISTRATION OF A MOTOR VEHICLE

NIT for Tender No. GCO 8644P13

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/48

Solar Energy Corporation of India Limited New Delhi Expression of Interest for Setting up of Solar PV Manufacturing Capacities in India

DIVISION 311 MISCELLANEOUS ELECTRICAL RULES

HARYANA POWER GENERATION CORPORATION LIMITED Regd. Office C-7, Urja Bhawan, Sector-6, Panchkula Corporate Identity Number: U45207HR1997SGC033517

THE CONNECTICUT LIGHT AND POWER COMPANY dba EVERSOURCE ENERGY AND THE UNITED ILLUMINATING COMPANY

KENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO

OFFICE OF SUPERINTENDENT DELAWARE COMMUNITY SCHOOL CORPORATION 9750 N CR 200 East Muncie, IN Phone: Fax:

Dakshin Gujarat Vij Company Limited

FREQUENTLY ASKED QUESTIONS ON AC REPLACEMENT SCHEME

PONDICHERRY UNIVERSITY ELECTRICAL WING Schedule

Transcription:

GRAMIN BANK OF ARYAVART HEAD OFFICE, A /6, VIJAYKHAND, GOMTINAGAR LUCKNOW ( U.P.) 600 Phone No- 7388800775/76/88/90-98, Fax No. 05-39986 Email Id www.aryavart rrb.com HO/A&S/VKS/ 66 DATE 8.07.03 TENDER NOTICE Quotation for electrical, data cabling, ups wiring earthing work in new / renovated Branches Garmin Bank of Aryavart a leading Gramin Bank having 65 branches, Regional offices having its operation in Hardoi,Unnao, Lucknow, Barabanki, Kannauj, Farrukhabad, Mainpuri,Aligarh, Mathura, Hathras, Agra,Ferozabad, Etah and Kasganj districts invites competitive rates for electrical work, data cabling, ups wiring, earthing work and solar wiring ( wherever required) at the proposed/ existing furnished / renovated branches and new branches to be opened( in the financial year 03 -) Separate tenders are to be submitted for each set( consisting or 3 districts) of districts. There are 6 sets which are marked as A, B, C, D, E&F. S.NO. SET OF DISTRICTS SET NUMBER TENDER FORM NUMBER Hardoi + Unnao A Annexure - I Lucknow + Barabanki B Annexure - II 3 Kannauj +Farrukhabad +Mainpuri C Annexure III Aligarh +Mathura +Hathras D Annexure IV 5 Agra + Ferozabad E Annexure V 6 Etah + Kasganj F Annexure VI TERMS AND CONDITIONS Submit your rates in closed envelope for each sets of District under following terms and condition: - Firms having minium experience of at least 5 years in electrical, data cabling, UPS wiring and earthing work are eligible to quote. Rates quoted should be inclusive of all type of charges, expenses, Taxes FOR within the districts for which the rates are given. 3 Quote your competitive rate on enclosed formats (Annexure I to Annexure VI) separately for each set ( A TO F) Incomplete and conditional quotation will be treated as cancelled. 5 If it is found that the material used is not same as mentioned in quotation then the bank has the right to reject the work and for this Bank will not make any payment as well as the said firm may be removed from the Bank s empanelled list. 6 If any type of change is required in electrical work it should be duly approved by the Chief Manager, administration and services department head office and the Regional Manager of Region where the branch is located. 7 If rates quoted by you are accepted to Bank then the electrical work is to be completed in given time, please note that if the work is not completed in given time then the bank has the right to impose the penalty at the rate of 3.00% for every 5 days delay. 8 Rates quoted will be valid upto 3.03.0. The bank reserves the right to place the order for each branch separately as the furnishing work at the premises is completed. 9 Note that the measurement, quantity of different items are tentative and may increase or decrease as per the requirement of the bank. The variation may be upto 0% 0 After the allotted work is completed the Regional Manager and the Chief Manager of A&S department, Head office or any officer authorize by the Chief Manager will verify the work. Note that the bank will not provide any advance against the work order. Bank will retain 5.00% cost of bill for 80 days while making the payment to cover the defect liability. 3 Note that before starting the electrical work, the material which is to be used should be duly certified by the Regional Manager or any officer deputed from the Head office. Quotation in a closed envelope (separate envelope for each region) must reach at head office positively on or before 30.07.03.All these envelopes should be placed in a big sealed envelope. 5 Note that only quoting the lowest rate is not eligibility, the banks may allot the work and in this regard the bank has the full right to accept or reject the one and all tenders without any notice. 6. Note carefully that Bank shall be under no obligation to accept the lowest or any other offer received in response to this tender. Order will be placed keeping in view all the norms, features, quality, performance, services, brand name and certification etc. The decision of the Bank in this regard will be final and binding. 7 Firms have to submit their details as per enclosed Annexure X along with required photocopy of papers required for verifications. The Annexure :- ( I to VI) tender forms are enclosed herewith. : - Format -X (A.Z.KHAN) GENERAL MANAGER

ANNEXURE I SET NUMBER - A GRAMIN BANK OF ARYAVART QUOTATION FOR DATA CABLING, UPS WIRING, EARTHING, ELECTRICAL WORK FOR PROPOSED NEWLY FURNISHED / PROPOSED NEW BRANCHES FOR HARDOI & UNNAO DISTRICTS ELECTRICAL WORK AND UPS WIRING 3 Nos. 00 Amps Kit kat set link type with neutral link Havells make with wooden board of size ft x ft.( ft x ft space for power meter) 03 No. Supply, Installation, Testing & Commissioning of main LT panel fabricated from CRCA Sheet.8 mm dust proof Incomer 00 Amp MCCB 5 KA Changeover FP 00 Amp Outgoing 63 Amp 0 KA TP MCB 3 Nos. for PP Db, Bus Bar 00 Amp, Cable entry from top & bottom 3 Havells make 6 sqr mm armound core Cable ( from supply point to main meter) 50 mtr. Havells make 6 sqr mm unarmound core Cable (for ups input) 5 mtr. 6 Supply ' Long Surface Electronic Tube light fitting *36w Crompton Greaves make planet model (DSG EB) with fitting 8 No. 8 Supply of angle holder for bulbs including cost of 5 Watt CFL of crompton greaves. 0 No. Supply of Wall mounted Fan 00 mm High Flow Wave Crompton greaves make with fitting 9 0 No. Supply of ceiling Fan 00 mm Sweep Winger Crompton greaves make (white colour) with fitting 3 S/F of Fresh air/ exhaust fan " Transair make Crompton with fitting 5 S/F of fresh air fan 50 mm Briskair Compton greaves make with fitting 7 63 Amp TP Rotary Switch for UPS Incomer main Line Havells make 8 Industrial Cable 00v(Coil).5 Sqr mm (P+N+E) with AKG make casing n Capping & laying UPS Wiring with Havells/Anchor 50 meter 9 Way SPN D.B Box Double Door of Havells 0 5 Amp 3 No. Way Switch & 5 Amp 3 No. Socket, No. Indicator Anchor make with 8*0 good quality Wooden Box & Sheet Havells 6 Amp MCB of Havells 0 Amp Isolator Double Pole with way MCB BOX 3 Havells 0 Amp MCB Double Pole with way MCB BOX 5 Amp Combined Switch & Socket (Gang Box) Anchor make 5 6 Amp Plug Top 6 6 Amp Plug Top

VOLTAGE STABILIZER FOR POWER VOLTAGE CONTROL WITH 3 YEARS REPLACEMENT WARRANTY S.NO. STABILIZER KVA SPACIFICATION STABLIZER VOLTAGE RANGE 0 70 V 90 70 V 7.50 KVA Output Voltage = 0v+/- % per phase Max Temp rise = 5 degree C above ambient. 0.00 KVA Output Voltage = 0v+/- % per phase Max Temp rise = 5 degree C above ambient. WIRING FOR POWER SUPPLY BY SOLAR POWER PACK IN SELECTED BRANCHES Wiring form output power supply from solar power pack to four ceiling fans. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm of Havells make. 00 meter Wiring from output supply from solar power pack to four CFL of 5 watts. CFL cost is inclusive. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm of Havells make. 00 meter Wiring from output power supply from solar power pack to four computers with TFT monitor, one pass book printer, one dot matrix printers, one scanner and power supply to V-SAT / Lease line 3 modem/switch etc. Wiring is to be done in casing. Change over for solar power supply and Grid power supply. 5 DATA CABLING S.NO. DESCRIPTION MAKE QUANTITY RATE QUOTED G 600 Cable Cat 6(copper UTP) D Link / Digi link 50 mts Information outlet Cat 6 (with single SMB), with D Link / Digi link 6 3 Information outlet Cat 6 (with double SMB), with D Link / Digi link Patch panel Cat 6 ( port), with installation D Link / Digi link 5 Patch cord mts. D Link / Digi link 5 6 Patch cord mts. D Link / Digi link 5 7 Steel rack (9U) wall mounted with -point power Valrack DB, one fan along with cable manager, with installation charges, setting of switch and router in rack with systemic manner. 8 Casing 9/9 mm, inch, AKS ( ISI) 75 mts 9 Casing 9/9 mm,.5 inch, AKS ( ISI) 75 mts 3 Structuring of data cabling cabling 50 mts LAN Diagram (map) in 3 copies, one for branch, one for Regional office, One for IT department at Head office. 5 Fixing of lease line / V-SAT Line in casing/ clamps. COST 3

EARTHING WORK Ash safe earthing electrode, Mainntance free earthing with electrodes of 3.00 mts, diameter 6 mm to 50 mm, CPRI & RDSO tested 3 303:987 with two bag compound, electrodes and 0 meter copper wire of 0.00 mm with electrodes.( wire to be in PVC pipe duly clamped with wall) (EARTHING WORK WITH 3 YEAR WARRENTY) EARTH NUTRAL VOLTAGE IS ALWAYS REQUIRED TO BE LESS THAN VOLTS. job with material Cost of 0.00 mm wire beyond 0 meter ( cost per meter) Note: - All Quantities / Measurements are subject to final measurement on site in the presence of Branch Manager/ Regional Manager/ any Bank official from A&S department, Head office and are subjected to variation upto 0%.( + or - ) Terms and conditions:- A. All the materials which are to be used must be of specified brand / quality as narrated above. All the items must be of first quality, no second / commercial material are to be used having any type of defect. B. Before installation/ fitting, all the material must be inspected and approved by the Branch Manager/ Regional Manager/ any Bank official from A&S department, use of defective / sub standard / non approved / non specified items will not be accepted under any circumstances and the entire work will be rejected for such type of discrepancies. C. The work if ordered is required to be completed in stipulated time, delay will attract penalty @3.00%for every block (each block consist of 5 days). D. Please quote your rates separately for each sets of districts (Annexure I to Annexure VI) for existing renovated branches/ proposed new branches to be opened.( Sets A to F) E. The quoted rates will be valid upto 3.03.0. F. The wires to be used of Havells / Anchor/ Finolex make and of proper thickness as stipulated by the Bank. G. Bank reserves the right to reject one or all quotations without giving any notice, Bank may also call fresh tenders at a short notice.

ANNEXURE II SET NUMBER - B GRAMIN BANK OF ARYAVART QUOTATION FOR DATA CABLING, UPS WIRING, EARTHING, ELECTRICAL WORK FOR PROPOSED NEW BRANCHES LUCKNOW & BARABANKI DISTRICT ELECTRICAL WORK AND UPS WIRING 3 Nos. 00 Amps Kit kat set link type with neutral link Havells make with wooden board of size ft x ft. 03 No. Supply, Installation, Testing & Commissioning of main LT panel fabricated from CRCA Sheet.8 mm dust proof Incomer 00 Amp MCCB 5 KA Changeover FP 00 Amp Outgoing 63 Amp 0 KA TP MCB 3 Nos. for PP Db, Bus Bar 00 Amp, Cable entry from top & bottom 3 Havells make 6 sqr mm armound core Cable 5 mtr. Havells make 6 sqr mm unarmound core Cable (for ups input) 5 mtr. 6 Supply ' Long Surface Electronic Tube light fitting *36w Crompton Greaves make planet model (DSG EB) with fitting 8 No. 8 Supply of angle holder for bulbs including cost of 5 Watt CFL of crompton greaves. 0 No. Supply of Wall mounted Fan 00 mm High Flow Wave Crompton greaves make with fitting 9 0 No. Supply of ceiling Fan 00 mm Sweep Winger Crompton greaves make (white colour) with fitting 3 S/F of Fresh air/ exhaust fan " Transair make Crompton with fitting 5 S/F of fresh air fan 50 mm Briskair Compton greaves make with fitting 7 63 Amp TP Rotary Switch for UPS Incomer main Line Havells make 8 Industrial Cable 00v(Coil).5 Sqr mm (P+N+E) with AKG make casing n Capping & laying UPS Wiring with Havells/Anchor 50 meter 9 Way SPN D.B Box Double Door of Havells 0 5 Amp 3 No. Way Switch & 5 Amp 3 No. Socket, No. Indicator Anchor make with 8*0 good quality Wooden Box & Sheet Havells 6 Amp MCB of Havells 0 Amp Isolator Double Pole with way MCB BOX 3 Havells 0 Amp MCB Double Pole with way MCB BOX 5 Amp Combined Switch & Socket (Gang Box) Anchor make 5 6 Amp Plug Top 6 6 Amp Plug Top 5

VOLTAGE STABILIZER FOR POWER VOLTAGE CONTROL WITH 3 YEARS REPLACEMENT WARRANTY S.NO. STABILIZER KVA SPACIFICATION 7.50 KVA Output Voltage = 0v+/- % per phase Max Temp rise = 5 degree C above ambient. 0.00 KVA Output Voltage = 0v+/- % per phase Max Temp rise = 5 degree C above ambient. STABLIZER VOLTAGE RANGE 0 70 V 90 70 V WIRING FOR POWER SUPPLY BY SOLAR POWER PACK. Wiring form output power supply from solar power pack to four ceiling fans. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm of Havells make. 00 meter Wiring from output supply from solar power pack to four CFL of 5 watts. CFL cost is inclusive. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm of Havells make. 00 meter Wiring from output power supply from solar power pack to four computers with TFT monitor, one pass book printer, one dot matrix printers, one scanner and power supply to V-SAT / Lease line 3 modem/switch etc. Wiring is to be done in casing. Change over for solar power supply and Grid power supply. 5 DATA CABLING S.NO. DESCRIPTION MAKE QUANTITY RATE QUOTED G 600 Cable Cat 6(copper UTP) D Link / Digi link 50 mts Information outlet Cat 6 (with single SMB), with D Link / Digi link 6 3 Information outlet Cat 6 (with double SMB), with D Link / Digi link Patch panel Cat 6 ( port), with installation D Link / Digi link 5 Patch cord mts. D Link / Digi link 5 6 Patch cord mts. D Link / Digi link 5 7 Steel rack (9U) wall mounted with -point power Valrack DB, one fan along with cable manager, with installation charges, setting of switch and router in rack with systemic manner. 8 Casing 9/9 mm, inch, AKS ( ISI) 75 mts 9 Casing 9/9 mm,.5 inch, AKS ( ISI) 75 mts 3 Structuring of data cabling cabling 50 mts LAN Diagram (map) in 3 copies, one for branch, one for Regional office, One for IT department at Head office. 5 Fixing of lease line / V-SAT Line in casing/ clamps. COST 6

EARTHING WORK Ash safe earthing electrode, Mainntance free earthing with electrodes of 3.00 mts, diameter 6 mm to 50 mm, CPRI & RDSO tested 3 303:987 with two bag compound, electrodes and 0 meter copper wire of 0.00 mm with electrodes.( wire to be in PVC pipe duly clamped with wall) (EARTHING WORK WITH 3 YEAR WARRENTY) EARTH NUTRAL VOLTAGE IS ALWAYS REQUIRED TO BE LESS THAN VOLTS. job with material Cost of 0.00 mm wire beyond 0 meter ( cost per meter) Note: - All Quantities / Measurements are subject to final measurement on site in the presence of Branch Manager/ Regional Manager/ any Bank official from A&S department, Head office and are subjected to variation upto 0%.(+ or -) Terms and conditions:- A. All the materials which are to be used must be of specified brand / quality as narrated above. All the items must be of first quality, no second / commercial material are to be used having any type of defect. B. Before installation/ fitting, all the material must be inspected and approved by the Branch Manager/ Regional Manager/ any Bank official from A&S department, use of defective / sub standard / non approved / non specified items will not be accepted under any circumstances and the entire work will be rejected for such type of discrepancies. C. The work if ordered is required to be completed in stipulated time, delay will attract penalty @3.00%for every block (each block consist of 5 days). D. Please quote your rates separately for each sets of districts ( Annexur I to Annexure VI) for existing renovated branches/ proposed new branches to be opened.( Set A to F) E. The quoted rates will be valid upto 3.03.0. F. The wires to be used of Havells / Anchor/ Finolex make and of proper thickness as stipulated by the Bank. G. Bank reserves the right to reject one or all quotations without giving any notice, Bank may also call fresh tenders at a short notice. 7

ANNEXURE III SET NUMBER - C GRAMIN BANK OF ARYAVART QUOTATION FOR DATA CABLING, UPS WIRING, EARTHING, ELECTRICAL WORK FOR PROPOSED NEW BRANCHES KANNAUJ, FARRUKHABAD & MAINPURI DISTRICT ELECTRICAL WORK AND UPS WIRING 3 Nos. 00 Amps Kit kat set link type with neutral link Havells make with wooden board of size ft x ft. 03 No. Supply, Installation, Testing & Commissioning of main LT panel fabricated from CRCA Sheet.8 mm dust proof Incomer 00 Amp MCCB 5 KA Changeover FP 00 Amp Outgoing 63 Amp 0 KA TP MCB 3 Nos. for PP Db, Bus Bar 00 Amp, Cable entry from top & bottom 3 Havells make 6 sqr mm armound core Cable 5 mtr. Havells make 6 sqr mm unarmound core Cable (for ups input) 5 mtr. 6 Supply ' Long Surface Electronic Tube light fitting *36w Crompton Greaves make planet model (DSG EB) with fitting 8 No. 8 Supply of angle holder for bulbs including cost of 5 Watt CFL of crompton greaves. 0 No. Supply of Wall mounted Fan 00 mm High Flow Wave Crompton greaves make with fitting 9 0 No. Supply of ceiling Fan 00 mm Sweep Winger Crompton greaves make (white colour) with fitting 3 S/F of Fresh air/ exhaust fan " Transair make Crompton with fitting 5 S/F of fresh air fan 50 mm Briskair Compton greaves make with fitting 7 63 Amp TP Rotary Switch for UPS Incomer main Line Havells make 8 Industrial Cable 00v(Coil).5 Sqr mm (P+N+E) with AKG make casing n Capping & laying UPS Wiring with Havells/Anchor 50 meter 9 Way SPN D.B Box Double Door of Havells 0 5 Amp 3 No. Way Switch & 5 Amp 3 No. Socket, No. Indicator Anchor make with 8*0 good quality Wooden Box & Sheet Havells 6 Amp MCB of Havells 0 Amp Isolator Double Pole with way MCB BOX 3 Havells 0 Amp MCB Double Pole with way MCB BOX 5 Amp Combined Switch & Socket (Gang Box) Anchor make 5 6 Amp Plug Top 6 6 Amp Plug Top 8

VOLTAGE STABILIZER FOR POWER VOLTAGE CONTROL WITH 3 YEARS REPLACEMENT WARRANTY S.NO. STABILIZER KVA SPACIFICATION 7.50 KVA Output Voltage = 0v+/- % per phase Max Temp rise = 5 degree C above ambient. 0.00 KVA Output Voltage = 0v+/- % per phase Max Temp rise = 5 degree C above ambient. STABLIZER VOLTAGE RANGE 0 70 V 90 70 V WIRING FOR POWER SUPPLY BY SOLAR POWER PACK. Wiring form output power supply from solar power pack to four ceiling fans. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm of Havells make. 00 meter Wiring from output supply from solar power pack to four CFL of 5 watts. CFL cost is inclusive. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm of Havells make. 00 meter Wiring from output power supply from solar power pack to four computers with TFT monitor, one pass book printer, one dot matrix printers, one scanner and power supply to V-SAT / Lease line 3 modem/switch etc. Wiring is to be done in casing. Change over for solar power supply and Grid power supply. 5 DATA CABLING S.NO. DESCRIPTION MAKE QUANTITY RATE QUOTED G 600 Cable Cat 6(copper UTP) D Link / Digi link 50 mts Information outlet Cat 6 (with single SMB), with D Link / Digi link 6 3 Information outlet Cat 6 (with double SMB), with D Link / Digi link Patch panel Cat 6 ( port), with installation D Link / Digi link 5 Patch cord mts. D Link / Digi link 5 6 Patch cord mts. D Link / Digi link 5 7 Steel rack (9U) wall mounted with -point power Valrack DB, one fan along with cable manager, with installation charges, setting of switch and router in rack with systemic manner. 8 Casing 9/9 mm, inch, AKS ( ISI) 75 mts 9 Casing 9/9 mm,.5 inch, AKS ( ISI) 75 mts 3 Structuring of data cabling cabling 50 mts LAN Diagram (map) in 3 copies, one for branch, one for Regional office, One for IT department at Head office. 5 Fixing of lease line / V-SAT Line in casing/ clamps. COST 9

EARTHING WORK Ash safe earthing electrode, Mainntance free earthing with electrodes of 3.00 mts, diameter 6 mm to 50 mm, CPRI & RDSO tested 3 303:987 with two bag compound, electrodes and 0 meter copper wire of 0.00 mm with electrodes.( wire to be in PVC pipe duly clamped with wall) (EARTHING WORK WITH 3 YEAR WARRENTY) EARTH NUTRAL VOLTAGE IS ALWAYS REQUIRED TO BE LESS THAN VOLTS. job with material Cost of 0.00 mm wire beyond 0 meter ( cost per meter) Note: - All Quantities / Measurements are subject to final measurement on site in the presence of Branch Manager/ Regional Manager/ any Bank official from A&S department, Head office and are subjected to variation upto 0%. ( + or -) Terms and conditions:- A. All the materials which are to be used must be of specified brand / quality as narrated above. All the items must be of first quality, no second / commercial material are to be used having any type of defect. B. Before installation/ fitting, all the material must be inspected and approved by the Branch Manager/ Regional Manager/ any Bank official from A&S department, use of defective / sub standard / non approved / non specified items will not be accepted under any circumstances and the entire work will be rejected for such type of discrepancies. C. The work if ordered is required to be completed in stipulated time, delay will attract penalty @3.00%for every block (each block consist of 5 days). D. Please quote your rates separately for each sets of districts (Annexure I to Annexure VI) for existing renovated branches/ proposed new branches to be opened. E. The quoted rates will be valid upto 3.03.0. F. The wires to be used of Havells / Anchor/ Finolex make and of proper thickness as stipulated by the Bank. G. Bank reserves the right to reject one or all quotations without giving any notice, Bank may also call fresh tenders at a short notice. 0

ANNEXURE IV SET NUMBER - D GRAMIN BANK OF ARYAVART QUOTATION FOR DATA CABLING, UPS WIRING, EARTHING, ELECTRICAL WORK FOR PROPOSED NEW BRANCHES ALIGARH, MATHURA & HATHRAS DISTRICTS ELECTRICAL WORK AND UPS WIRING 3 Nos. 00 Amps Kit kat set link type with neutral link Havells make with wooden board of size ft x ft. 03 No. Supply, Installation, Testing & Commissioning of main LT panel fabricated from CRCA Sheet.8 mm dust proof Incomer 00 Amp MCCB 5 KA Changeover FP 00 Amp Outgoing 63 Amp 0 KA TP MCB 3 Nos. for PP Db, Bus Bar 00 Amp, Cable entry from top & bottom 3 Havells make 6 sqr mm armound core Cable 5 mtr. Havells make 6 sqr mm unarmound core Cable (for ups input) 5 mtr. 6 Supply ' Long Surface Electronic Tube light fitting *36w Crompton Greaves make planet model (DSG EB) with fitting 8 No. 8 Supply of angle holder for bulbs including cost of 5 Watt CFL of crompton greaves. 0 No. Supply of Wall mounted Fan 00 mm High Flow Wave Crompton greaves make with fitting 9 0 No. Supply of ceiling Fan 00 mm Sweep Winger Crompton greaves make (white colour) with fitting 3 S/F of Fresh air/ exhaust fan " Transair make Crompton with fitting 5 S/F of fresh air fan 50 mm Briskair Compton greaves make with fitting 7 63 Amp TP Rotary Switch for UPS Incomer main Line Havells make 8 Industrial Cable 00v(Coil).5 Sqr mm (P+N+E) with AKG make casing n Capping & laying UPS Wiring with Havells/Anchor 50 meter 9 Way SPN D.B Box Double Door of Havells 0 5 Amp 3 No. Way Switch & 5 Amp 3 No. Socket, No. Indicator Anchor make with 8*0 good quality Wooden Box & Sheet Havells 6 Amp MCB of Havells 0 Amp Isolator Double Pole with way MCB BOX 3 Havells 0 Amp MCB Double Pole with way MCB BOX 5 Amp Combined Switch & Socket (Gang Box) Anchor make 5 6 Amp Plug Top 6 6 Amp Plug Top

VOLTAGE STABILIZER FOR POWER VOLTAGE CONTROL WITH 3 YEARS REPLACEMENT WARRANTY S.NO. STABILIZER KVA SPACIFICATION 7.50 KVA Output Voltage = 0v+/- % per phase Max Temp rise = 5 degree C above ambient. 0.00 KVA Output Voltage = 0v+/- % per phase Max Temp rise = 5 degree C above ambient. STABLIZER VOLTAGE RANGE 0 70 V 90 70 V WIRING FOR POWER SUPPLY BY SOLAR POWER PACK. Wiring form output power supply from solar power pack to four ceiling fans. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm of Havells make. 00 meter Wiring from output supply from solar power pack to four CFL of 5 watts. CFL cost is inclusive. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm of Havells make. 00 meter Wiring from output power supply from solar power pack to four computers with TFT monitor, one pass book printer, one dot matrix printers, one scanner and power supply to V-SAT / Lease line 3 modem/switch etc. Wiring is to be done in casing. Change over for solar power supply and Grid power supply. 5 DATA CABLING S.NO. DESCRIPTION MAKE QUANTITY RATE QUOTED G 600 Cable Cat 6(copper UTP) D Link / Digi link 50 mts Information outlet Cat 6 (with single SMB), with D Link / Digi link 6 3 Information outlet Cat 6 (with double SMB), with D Link / Digi link Patch panel Cat 6 ( port), with installation D Link / Digi link 5 Patch cord mts. D Link / Digi link 5 6 Patch cord mts. D Link / Digi link 5 7 Steel rack (9U) wall mounted with -point power Valrack DB, one fan along with cable manager, with installation charges, setting of switch and router in rack with systemic manner. 8 Casing 9/9 mm, inch, AKS ( ISI) 75 mts 9 Casing 9/9 mm,.5 inch, AKS ( ISI) 75 mts 3 Structuring of data cabling cabling 50 mts LAN Diagram (map) in 3 copies, one for branch, one for Regional office, One for IT department at Head office. 5 Fixing of lease line / V-SAT Line in casing/ clamps. COST

EARTHING WORK Ash safe earthing electrode, Mainntance free earthing with electrodes of 3.00 mts, diameter 6 mm to 50 mm, CPRI & RDSO tested 3 303:987 with two bag compound, electrodes and 0 meter copper wire of 0.00 mm with electrodes.( wire to be in PVC pipe duly clamped with wall) (EARTHING WORK WITH 3 YEAR WARRENTY) EARTH NUTRAL VOLTAGE IS ALWAYS REQUIRED TO BE LESS THAN VOLTS. job with material Cost of 0.00 mm wire beyond 0 meter ( cost per meter) Note: - All Quantities / Measurements are subject to final measurement on site in the presence of Branch Manager/ Regional Manager/ any Bank official from A&S department, Head office and are subjected to variation upto 0%.( +or -) Terms and conditions:- A. All the materials which are to be used must be of specified brand / quality as narrated above. All the items must be of first quality, no second / commercial material are to be used having any type of defect. B. Before installation/ fitting, all the material must be inspected and approved by the Branch Manager/ Regional Manager/ any Bank official from A&S department, use of defective / sub standard / non approved / non specified items will not be accepted under any circumstances and the entire work will be rejected for such type of discrepancies. C. The work if ordered is required to be completed in stipulated time, delay will attract penalty @3.00%for every block (each block consist of 5 days). D. Please quote your rates separately for each sets of districts ( Annexure I to Annexure VI) for existing renovated branches/ proposed new branches to be opened.(sets A to F) E. The quoted rates will be valid upto 3.03.0. F. The wires to be used of Havells / Anchor/ Finolex make and of proper thickness as stipulated by the Bank. G. Bank reserves the right to reject one or all quotations without giving any notice, Bank may also call fresh tenders at a short notice. 3

ANNEXURE V SET NUMBER - E GRAMIN BANK OF ARYAVART QUOTATION FOR DATA CABLING, UPS WIRING, EARTHING, ELECTRICAL WORK FOR PROPOSED NEW BRANCHES AGRA & FEROZABAD DISTRICTS ELECTRICAL WORK AND UPS WIRING 3 Nos. 00 Amps Kit kat set link type with neutral link Havells make with wooden board of size ft x ft. 03 No. Supply, Installation, Testing & Commissioning of main LT panel fabricated from CRCA Sheet.8 mm dust proof Incomer 00 Amp MCCB 5 KA Changeover FP 00 Amp Outgoing 63 Amp 0 KA TP MCB 3 Nos. for PP Db, Bus Bar 00 Amp, Cable entry from top & bottom 3 Havells make 6 sqr mm armound core Cable 5 mtr. Havells make 6 sqr mm unarmound core Cable (for ups input) 5 mtr. 6 Supply ' Long Surface Electronic Tube light fitting *36w Crompton Greaves make planet model (DSG EB) with fitting 8 No. 8 Supply of angle holder for bulbs including cost of 5 Watt CFL of crompton greaves. 0 No. Supply of Wall mounted Fan 00 mm High Flow Wave Crompton greaves make with fitting 9 0 No. Supply of ceiling Fan 00 mm Sweep Winger Crompton greaves make (white colour) with fitting 3 S/F of Fresh air/ exhaust fan " Transair make Crompton with fitting 5 S/F of fresh air fan 50 mm Briskair Compton greaves make with fitting 7 63 Amp TP Rotary Switch for UPS Incomer main Line Havells make 8 Industrial Cable 00v(Coil).5 Sqr mm (P+N+E) with AKG make casing n Capping & laying UPS Wiring with Havells/Anchor 50 meter 9 Way SPN D.B Box Double Door of Havells 0 5 Amp 3 No. Way Switch & 5 Amp 3 No. Socket, No. Indicator Anchor make with 8*0 good quality Wooden Box & Sheet Havells 6 Amp MCB of Havells 0 Amp Isolator Double Pole with way MCB BOX 3 Havells 0 Amp MCB Double Pole with way MCB BOX 5 Amp Combined Switch & Socket (Gang Box) Anchor make 5 6 Amp Plug Top 6 6 Amp Plug Top

VOLTAGE STABILIZER FOR POWER VOLTAGE CONTROL WITH 3 YEARS REPLACEMENT WARRANTY S.NO. STABILIZER KVA SPACIFICATION 7.50 KVA Output Voltage = 0v+/- % per phase Max Temp rise = 5 degree C above ambient. 0.00 KVA Output Voltage = 0v+/- % per phase Max Temp rise = 5 degree C above ambient. STABLIZER VOLTAGE RANGE 0 70 V 90 70 V WIRING FOR POWER SUPPLY BY SOLAR POWER PACK. Wiring form output power supply from solar power pack to four ceiling fans. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm of Havells make. 00 meter Wiring from output supply from solar power pack to four CFL of 5 watts. CFL cost is inclusive. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm of Havells make. 00 meter Wiring from output power supply from solar power pack to four computers with TFT monitor, one pass book printer, one dot matrix printers, one scanner and power supply to V-SAT / Lease line 3 modem/switch etc. Wiring is to be done in casing. Change over for solar power supply and Grid power supply. 5 DATA CABLING S.NO. DESCRIPTION MAKE QUANTITY RATE QUOTED G 600 Cable Cat 6(copper UTP) D Link / Digi link 50 mts Information outlet Cat 6 (with single SMB), with D Link / Digi link 6 3 Information outlet Cat 6 (with double SMB), with D Link / Digi link Patch panel Cat 6 ( port), with installation D Link / Digi link 5 Patch cord mts. D Link / Digi link 5 6 Patch cord mts. D Link / Digi link 5 7 Steel rack (9U) wall mounted with -point power Valrack DB, one fan along with cable manager, with installation charges, setting of switch and router in rack with systemic manner. 8 Casing 9/9 mm, inch, AKS ( ISI) 75 mts 9 Casing 9/9 mm,.5 inch, AKS ( ISI) 75 mts 3 Structuring of data cabling cabling 50 mts LAN Diagram (map) in 3 copies, one for branch, one for Regional office, One for IT department at Head office. 5 Fixing of lease line / V-SAT Line in casing/ clamps. COST 5

EARTHING WORK Ash safe earthing electrode, Mainntance free earthing with electrodes of 3.00 mts, diameter 6 mm to 50 mm, CPRI & RDSO tested 3 303:987 with two bag compound, electrodes and 0 meter copper wire of 0.00 mm with electrodes.( wire to be in PVC pipe duly clamped with wall) (EARTHING WORK WITH 3 YEAR WARRENTY) EARTH NUTRAL VOLTAGE IS ALWAYS REQUIRED TO BE LESS THAN VOLTS. job with material Cost of 0.00 mm wire beyond 0 meter ( cost per meter) Note: - All Quantities / Measurements are subject to final measurement on site in the presence of Branch Manager/ Regional Manager/ any Bank official from A&S department, Head office and are subjected to variation upto 0%. Terms and conditions:- A. All the materials which are to be used must be of specified brand / quality as narrated above. All the items must be of first quality, no second / commercial material are to be used having any type of defect. B. Before installation/ fitting, all the material must be inspected and approved by the Branch Manager/ Regional Manager/ any Bank official from A&S department, use of defective / sub standard / non approved / non specified items will not be accepted under any circumstances and the entire work will be rejected for such type of discrepancies. C. The work if ordered is required to be completed in stipulated time, delay will attract penalty @3.00%for every block (each block consist of 5 days). D. Please quote your rates separately for each sets of districts (Annexure I to Annexure VI) for existing renovated branches/ proposed new branches to be opened ( Set A to F) E. The quoted rates will be valid upto 3.03.0. F. The wires to be used of Havells / Anchor/ Finolex make and of proper thickness as stipulated by the Bank. G. Bank reserves the right to reject one or all quotations without giving any notice, Bank may also call fresh tenders at a short notice. 6

ANNEXURE VI SET NUMBER -F GRAMIN BANK OF ARYAVART QUOTATION FOR DATA CABLING, UPS WIRING, EARTHING, ELECTRICAL WORK FOR PROPOSED NEW BRANCHES ETAH & KASGANJ DISTRICTS ELECTRICAL WORK AND UPS WIRING 3 Nos. 00 Amps Kit kat set link type with neutral link Havells make with wooden board of size ft x ft. 03 No. Supply, Installation, Testing & Commissioning of main LT panel fabricated from CRCA Sheet.8 mm dust proof Incomer 00 Amp MCCB 5 KA Changeover FP 00 Amp Outgoing 63 Amp 0 KA TP MCB 3 Nos. for PP Db, Bus Bar 00 Amp, Cable entry from top & bottom 3 Havells make 6 sqr mm armound core Cable 5 mtr. Havells make 6 sqr mm unarmound core Cable (for ups input) 5 mtr. 6 Supply ' Long Surface Electronic Tube light fitting *36w Crompton Greaves make planet model (DSG EB) with fitting 8 No. 8 Supply of angle holder for bulbs including cost of 5 Watt CFL of crompton greaves. 0 No. Supply of Wall mounted Fan 00 mm High Flow Wave Crompton greaves make with fitting 9 0 No. Supply of ceiling Fan 00 mm Sweep Winger Crompton greaves make (white colour) with fitting 3 S/F of Fresh air/ exhaust fan " Transair make Crompton with fitting 5 S/F of fresh air fan 50 mm Briskair Compton greaves make with fitting 7 63 Amp TP Rotary Switch for UPS Incomer main Line Havells make 8 Industrial Cable 00v(Coil).5 Sqr mm (P+N+E) with AKG make casing n Capping & laying UPS Wiring with Havells/Anchor 50 meter 9 Way SPN D.B Box Double Door of Havells 0 5 Amp 3 No. Way Switch & 5 Amp 3 No. Socket, No. Indicator Anchor make with 8*0 good quality Wooden Box & Sheet Havells 6 Amp MCB of Havells 0 Amp Isolator Double Pole with way MCB BOX 3 Havells 0 Amp MCB Double Pole with way MCB BOX 5 Amp Combined Switch & Socket (Gang Box) Anchor make 5 6 Amp Plug Top 6 6 Amp Plug Top 7

VOLTAGE STABILIZER FOR POWER VOLTAGE CONTROL WITH 3 YEARS REPLACEMENT WARRANTY S.NO. STABILIZER KVA SPACIFICATION 7.50 KVA Output Voltage = 0v+/- % per phase Max Temp rise = 5 degree C above ambient. 0.00 KVA Output Voltage = 0v+/- % per phase Max Temp rise = 5 degree C above ambient. STABLIZER VOLTAGE RANGE 0 70 V 90 70 V WIRING FOR POWER SUPPLY BY SOLAR POWER PACK. Wiring form output power supply from solar power pack to four ceiling fans. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm of Havells make. 00 meter Wiring from output supply from solar power pack to four CFL of 5 watts. CFL cost is inclusive. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm of Havells make. 00 meter Wiring from output power supply from solar power pack to four computers with TFT monitor, one pass book printer, one dot matrix printers, one scanner and power supply to V-SAT / Lease line 3 modem/switch etc. Wiring is to be done in casing. Change over for solar power supply and Grid power supply. 5 DATA CABLING S.NO. DESCRIPTION MAKE QUANTITY RATE QUOTED G 600 Cable Cat 6(copper UTP) D Link / Digi link 50 mts Information outlet Cat 6 (with single SMB), with D Link / Digi link 6 3 Information outlet Cat 6 (with double SMB), with D Link / Digi link Patch panel Cat 6 ( port), with installation D Link / Digi link 5 Patch cord mts. D Link / Digi link 5 6 Patch cord mts. D Link / Digi link 5 7 Steel rack (9U) wall mounted with -point power Valrack DB, one fan along with cable manager, with installation charges, setting of switch and router in rack with systemic manner. 8 Casing 9/9 mm, inch, AKS ( ISI) 75 mts 9 Casing 9/9 mm,.5 inch, AKS ( ISI) 75 mts 3 Structuring of data cabling cabling 50 mts LAN Diagram (map) in 3 copies, one for branch, one for Regional office, One for IT department at Head office. 5 Fixing of lease line / V-SAT Line in casing/ clamps. COST 8

EARTHING WORK Ash safe earthing electrode, Mainntance free earthing with electrodes of 3.00 mts, diameter 6 mm to 50 mm, CPRI & RDSO tested 3 303:987 with two bag compound, electrodes and 0 meter copper wire of 0.00 mm with electrodes.( wire to be in PVC pipe duly clamped with wall) (EARTHING WORK WITH 3 YEAR WARRENTY) EARTH NUTRAL VOLTAGE IS ALWAYS REQUIRED TO BE LESS THAN VOLTS. job with material Cost of 0.00 mm wire beyond 0 meter ( cost per meter) Note: - All Quantities / Measurements are subject to final measurement on site in the presence of Branch Manager/ Regional Manager/ any Bank official from A&S department, Head office and are subjected to variation upto 0%. Terms and conditions:- A. All the materials which are to be used must be of specified brand / quality as narrated above. All the items must be of first quality, no second / commercial material are to be used having any type of defect. B. Before installation/ fitting, all the material must be inspected and approved by the Branch Manager/ Regional Manager/ any Bank official from A&S department, use of defective / sub standard / non approved / non specified items will not be accepted under any circumstances and the entire work will be rejected for such type of discrepancies. C. The work if ordered is required to be completed in stipulated time, delay will attract penalty @3.00%for every block (each block consist of 5 days). D. Please quote your rates separately for each sets of districts ( Annexur I to Annexure VI) for existing renovated branches/ proposed new branches to be opened ( Set A to F) E. The quoted rates will be valid upto 3.03.0. F. The wires to be used of Havells / Anchor/ Finolex make and of proper thickness as stipulated by the Bank. G. Bank reserves the right to reject one or all quotations without giving any notice, Bank may also call fresh tenders at a short notice. 9

(FORMAT X) GRAMIN BANK OF ARYAVART HEAD OFFICE, A /6, VIJAYKHAND, GOMTINAGAR LUCKNOW (U.P.) 600 Phone No- 7388800775/76/88/90-98, Fax No. 05-39986 Email Id www.aryavart rrb.com Electrical, data cabling, ups wiring earthing work in existing renovated branches / new Branches. Name of Firm / Organization. Address with Telephone No (I) Residence (ii)office/shop/godown. (iii) Website (iv) Email 3. Nature of Constitution of office/shop/ workshop. Date of Establishment 5. Name of the Proprietor/Partners/Directors with Residential address and Telephone No. (i) (ii) (iii) 6. Whether as S.S.I. unit if so, Reg. No. And Date. Also enclose copy of Certificate 7. Whether Registered with the Registrar of the Companies/Registrar of Firms. If so mention number and date. 8. Whether the premises (Press/Office/ Shop/ Factory) is/are owned or hired. 9. Name and address of the Banker's (Please enclose solvency certificate from the Banker's) 0. Whether registered for Trade-Tax Purposes. If so, mention No. And Date. Please also furnish Trade-Tax Clearance Certificate.. Whether an assessee of Income Tax if so, mention permanent account number. Please also furnish photocopy of income Tax return for the last three years. 0

. Copies of Audited Balance Sheets and Profit & Loss Account Statement for the last 3 years to be furnished. 3. If registered in the panel of other Organizations. Statutory bodies furnish their names, category and date of registration. (i) (ii). What are your lines of activities? Mention the fields on preference basis. (i) (ii) (iii) 5. Whether willing to work in GRAMIN BANK OF ARYAVART having its branches in Hardoi, Unnao, Lucknow, Barabanki, Kannauj, Farrukhabad, Mainpuri Ferozabad, Aligarh, Agra, Etah,Mathura, Hathras and Kasganj Districts. 6. (i) Detailed description and value of works done For others in the past.( Please photocopy of work orders) (ii) Detailed description and value of works done for the banks..( Please photocopy of work orders) 7. Specify the maximum value of works executed in a year. 8. Furnish the names of three responsible persons/bodies who will be in a position to certify about the quality as well as past performance of your organization. (i) (ii) (iii) 9. Names and addresses of the principal customers (Enclose certified copies of the latest orders). Note: Where copies are required to be furnished these are to be certified preferably by the concerned agencies or a Government Officer. PROFORMA I PARTICULARS IN RESPECT OF THE WORK EXECUTED. Name of Work/Project with Short Name and description Value of work Stipulated time of Actual time of completion. address Address of work owner executed completion executed 3 5 OTHER RELEVANT INFORMATION

. Whether worked for the Comercial Banks / Gramin banks, if yes, since when & for which Gramin Bank.. Capacity to execute one time order (Please mentioned the total amount and delivery period required) 3. Any other information. KEY PERSONNEL PERMANENTLY EMPLOYED WORK FORCE Permanently Employed No. Since when in the Employment Others OFFICE/ WORKSHOP/STORAGE FACILITIES Location Land Area Owned /Rented Type of Structure Type of Facility( Brief particulars of machines/ equipments) I/We declare that the particulars furnished above are true and correct and I shall abide by all the terms and conditions of the empanelment. And fully agree with the conditions / norms of the Bank,In case any information/particular is found incorrect at a later date, the application/empanelment is liable to be cancelled. Date: Place: Signature of the Applicant. (With Rubber Stamp)