OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Similar documents
OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Self-Priming Centrifugal Pumps

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

OWNER S MANUAL CP, CB SERIES CENTRIFUGAL PUMP

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

MS Series. Call Multi-Stage Deep Well Jet Pumps. For further operating, installation, or maintenance assistance:

PENTEK XE-6. OWNER S MANUAL 6 Submersible Motors 293 WRIGHT STREET, DELAVAN, WI PH: PENTEK

Vertical Jet Pumps. SSJ Series. Call OWNER S MANUAL

Model B1-1/2XQBS-11. Model B1-1/2XQBS-18. Model B1-1/2XQBS-26

SUBMERSIBLE SWIMMING POOL DRAINER

6 and 8 HAIR AND LINT STRAINERS

Submersible Solids Handling Pumps

SAE Engine Mount. Selection For Pumping Application. Matching Pump End To Engine. Type B Centrifugal Pumps Close coupled pump ends.

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B

Heater Manifold REPLACEMENT INSTRUCTIONS. Sta-Rite Pool/Spa Group. 293 Wright Street, Delavan, WI 53115

HALLMARK INDUSTRIES INC

SN Series / Série SN / Serie SN HN Series / Série HN / Serie HN

Models 3305P, 3307P, 3310P

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

ESE Series Cast Iron Sewage Pumps

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Model FM2260 Wall Mount. Full Motion Television Wall Mount

Series FP4100. Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien,

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

D SERIES CENTRIFUGAL PUMPS WITH TRAP FOR SWIMMING POOL USE

Call DS3 Series. Installation/Operation/Parts For further operating, installation, or maintenance assistance:

SHALLOW WELL JET PUMP

MH Series - Horizontal Multistage Pump OWNER'S MANUAL

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

SP40 Submersible Sewage Ejector Pump

5PNP15H. Call Installation/Operation/Parts For further operating, installation, or maintenance assistance:

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Flotec Pumps FP Click here for Pricing/Ordering for Pumps and Parts MOD. FP5230. Installation/Fonctionnement/Pièces

Self-Priming Horizontal Three and Four Stage Pumps

STAR STOP SHALLOW WELL JET PUMP

Installation Manual DIAPHRAGM WELL TANK

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

SHEF30 Submersible Sump/ Effluent Pump

Operating Instructions & Parts Manual. Model RCHW100

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

PUMP PRIMING INSTALLATION CHECK MOTOR ROTATION PUMP START-UP MOTOR REPLACEMENT DISASSEMBLY ELECTRICAL HOOKUP ASSEMBLY

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS

SPECIFICATIONS Power supply required...see Motor and Cord Specifications chart below Motor duty...intermittent Discharge Adapter...

Installation & Operating Manual

Submersible Sewage Ejector Pump

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

END SUCTION CENTRIFUGAL PUMPS

HN series. cast iron shallow well jet pumps. 1/2 thru 1 HP

Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

F PRO. 12 Volt Battery Powered Sprayer LIMITED WARRANTY. Part #AS75 Copyright 2014 by Hydro-Force Rev. 1/14

LIMITED WARRANTY. Some products and sizes may be discontinued when stock is depleted, or may require a minimum quantity for ordering.

MetroPrime 22MPC Self-Priming Centrifugal Pump

NECO Pumping Systems

Owner s Manual GLASSLINED PUMP TANK

AUTOMATIC SUBMERSIBLE UTILITY PUMP

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Installation and Service Manual OSP50/OSP50AB Submersible Effluent Pumps

OWNER s MANUAL Signature 2000 High Pressure Booster Pump 60 Hz. 1/2 through 3 HP

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )

6TSP Series Radial Flow

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

INSTALLATION AND SERVICE MANUAL MSKV50 Submersible Sewage Ejector Pump

Artesian Owners Manual

StormPro BA Series Sump Pump

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

END SUCTION CENTRIFUGAL PUMPS

MODELS 125M/B, 150M/B and 200M/B

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

60 Series End-Mount Brake Instructions Standard Housing

TPHK Series Immersible Pump

MODELS 125M/B, 150M/B and 200M/B

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

TPAK Series COOLANT PUMP

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )

Ultimate Mx II. Parts List E psi (228 bar, 22.8 MPa) Maximum Working Pressure. Vac Model Type Lo-Boy Hi-Boy. Sherwin Williams 120V

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

SUBMERSIBLE SUMP PUMPS

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

GARDEN HOSE UTILITY PUMP

36" Galvanized Direct Drive Hyflo Fan Installation and Operators Instruction Manual. Fan and Framing Dimensions

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

PARTS AND INSTALLATION MANUAL

SUNC3000 / Item #40885

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

OPERATOR S MANUAL. MODEL ORDER # MODEL HD 2.0/10 Ed HE D HD 1.8/14 Ed HE D

Thermal. Dimensions Torque Rotating. Rotating Capacity lb.ft. HPS/Min. Lb-Ft

Installation & Operation Manual

Penguin Gentoo 600B Cordless Sprayer User s Manual

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

INSTALLATION AND SERVICE MANUAL

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG BUNN-O-MATIC CORPORATION

Transcription:

OWNERS MNUL INSTLLTION ND OPERTING INSTRUCTIONS REPIR PRTS LIST Horizontal Multi-Stage Jet Pumps HMS-1FL Series MODELS 3/4 HP 1 HP 1-1/2 HP HMSD-1FL HMSE-1FL HMSF-1FL ST-RITE INDUSTRIES, INC. 293 Wright St., Delavan, WI 53115 1998, Sta-Rite Industries, Inc. Printed in U.S.. S1002 (Rev. 5/11/98)

Deep Well Installation Under certain conditions, horizontal multistage pumps can develop extremely high pressure. Install a pressure relief valve capable of passing entire pump flow at 75 PSI. Do not allow pump, pressure tank, piping, or any other system component containing water to freeze. Freezing may damage system, leading to injury or flooding. llowing pump or system components to freeze will void warranty. NOTICE: Support pump base to avoid strain on casing adapter or pump. Lack of support can damage adapter or pump. Figure 2 shows casing adapter bolted directly to pump body. 278 1093 Pipe fittings not furnished Regulator 1" Close nipple & 90 Elbow To Service Drain Plug Priming Regulator djusting Priming Plug Plastic Pipe dapter (2) Hose Clamp (2) Plastic Hose (2) Drive Line Suction Line Shallow Well Installation NOTICE: If no foot valve is used, install 1 check valve in horizontal line. Priming the Deep Well Pump To prime pump, completely close the priming valve located just below the suction opening by turning screw clockwise. This valve will be left closed during operation in a deep well installation. See Figure 1. Close regulator adjusting valve, located on end of regulator, by turning stem clockwise. See Figure 1. Remove priming plug from top of regulator valve, see Figure 1, and fill with clean water. Replace plug. Start pump and run a few moments. If pressure does not build up, remove priming plug and refill with more water. ll of the trapped air in pump body was not removed. Restart pump. When pump is completely primed and builds up pressure, slowly open the regulator valve, (turn counter-clockwise), and observe the pressure reading on the pressure gauge. When the pump reaches a point where it will lose prime, cavitation noise can be heard. The best, or correct, pressure gauge setting is approximately 3 pounds higher than the pressure gauge reading was when the pump started to lose prime. If pump loses prime, repeat the priming procedure above and this time open regulator valve only until the correct pressure reading is reached. If a vacuum gauge is available, screw it into the 1/8 VC tapping on front of tank body. djust regulator until 20 of vacuum is registered on the gauge. Tighten locknut on regulator. This method will give maximum performance of the unit. Figure 1 Deep Well Installation Priming Plug Regulator Priming Plug & 1/2" Street Elbow To Service To Service 1" Pipe Plug Plastic Pipe dapter Hose Clamp Plastic Hose 279 1093 240 1093 Priming From Well Pipe fittings not furnished Figure 2 Well Casing dapter bolted directly to pump Figure 3 Shallow Well Installation 2

HMSC pumps come equipped with pressure switch set to operate within a 20-40 PSI range. HMSD, HMSE, and HMSF pumps have 30-50 PSI pressure switches. When pump is used with precharged tank in system, set tank pre-charge at 18 PSI with a 20-40 PSI switch; set tank pre-charge at 28 PSI with a 30-50 PSI switch. Check tank pre-charge annually with an ordinary tire gauge. Pre-charge is set with no water pressure on system. Priming the Shallow Well Pump Never run pump dry. Running pump without water may cause pump to overheat, damaging seal and possibly causing burns to persons handling pump. Fill pump with water before starting. Service Draining for Winter Do not touch an operating motor. Modern motors are designed to operate at high temperatures. To avoid burns when servicing pump, allow it to cool for 20 minutes after shut-down before handling. When the pump is to be disconnected from service, or is in danger of freezing, it should be drained. The pump has a drain plug which must be removed. Remove the priming plug to vent the pump. If pump and motor are damaged due to freezing, the Warranty is void. Never run pump against closed discharge. To do so can boil water inside pump, causing hazardous pressure in unit, risk of explosion and possibly scalding persons handling pump. To prime the pump, completely open the priming valve located just below the suction opening on the tank body by turning the valve stem counter-clockwise all the way until it stops. This valve may be left open during operation as a shallow well pump with no jet. See Figure 3 and NOTICE below. Remove priming plug from top of elbow (see Figure 3), and fill with clean water. Replace plug. Start pump and between 45-60 seconds. If water is not being pumped, turn off pump and repeat priming process. NOTICE: If a bolt-on jet is being used, after pump is primed, close the priming valve during operation as a shallow well pump. TBLE I Recommended Fusing and Wiring Data 60 Cycle Motors DISTNCE IN FEET FROM MOTOR TO METER BRNCH 0 101 201 301 401 MX. FUSE* to to to to to MOTOR LOD RTING 100 200 300 400 500 HP VOLTS MPERES MPS WIRE SIZE 3/4 115 14.8 20 12 8 6 6 4 3/4 230 7.4 15 14 14 14 12 10 1 115 19.2 25 10 8 6 4 4 1 230 9.6 15 14 14 12 10 10 1-1/2 115 24.0 30 10 6 6 4 3 1-1/2 230 12.0 15 14 14 12 10 10 *Fusetrons are recommended instead of fuses on all motor circuits. 3

Electrical Disconnect power before working on pump, motor, pressure switch, or wiring. Your Motor Terminal Board (under the motor end cover) and Pressure Switch look like one of those shown below. Convert to 115 Volts as shown. Do not change motor wiring if line voltage is 230 Volts or if you have a single voltage motor. Connect power supply as shown for your type of switch and your supply voltage. 1. 230 Volt to 115 Volt Conversion, Plug-in Type: Pull plug straight out from terminal board. 1. 230 Volts 115 Volts 2. Plug in again with arrow on plug pointing to '115 Volts'. 2. 230 Volts 115 Volts Ground Screw Motor wires connect here. Power supply wires connect here. 230 Volt: Connect 2 hot wires (black and red) here and cap the white (neutral) wire. It does not matter which wire goes to which screw. 115 Volt: Connect one hot wire (black or red) to one of these screws (it doesn't matter which one). Connect the white (neutral) wire to the other screw. Cap any remaining black or red wires. Clamp the power cable to prevent strain on the terminal screws. Connect the green (or bare copper) ground wire to the green ground screw. 230 Volt to 115 Volt Conversion, Spade Connector Type: 1. Move black wire from to. 1. B L2 2. Move white wire with black tracer from B to. 2. B L2 3. Change Complete: 3. B L2 Ground Screw 3187 0398 Motor wires connect here. Power supply wires connect here. 230 Volt: Connect 2 hot wires (black and red) here and cap the white (neutral) wire. It does not matter which wire goes to which screw. 115 Volt: Connect one hot wire (black or red) to one of these screws (it doesn't matter which one). Connect the white (neutral) wire to the other screw. Cap any remaining black or red wires. Clamp the power cable to prevent strain on the terminal screws. Connect the green (or bare copper) ground wire to the green ground screw. 3187 0398 Figure 4: Motor wiring connections through Pressure Switch. Match motor voltage to line voltage. Hazardous voltage. Can shock, burn, or kill. Connect ground wire before connecting power supply wires. Use the wire size (including the ground wire) specified in the wiring chart. If possible, connect the pump to a separate branch circuit with no other appliances on it. supply line. WIRING CONNECTIONS Explosion hazard. Do not ground to a gas Fire hazard. Incorrect voltage can cause a fire or seriously damage the motor and voids the warranty. The supply voltage must be within ±10% of the motor nameplate voltage. NOTICE: Dual-voltage motors are factory wired for 230 volts. If necessary, reconnect the motor for 115 volts, as shown. Do not alter the wiring in single voltage motors. Install, ground, wire, and maintain your pump in compliance with the National Electrical Code (NEC) or the Canadian Electrical Code (CEC), as applicable, and with all local codes and ordinances that apply. Consult your local building inspector for code information. Connection Procedure: 1. Connect the ground wire first as shown in Figure 4. The ground wire must be a solid copper wire at least as large as the power supply wires. 2. There must be a solid metal connection between the pressure switch and the motor for motor grounding protection. If the pressure switch is not connected to the motor, connect the green ground screw in the switch to the green ground screw under the motor end cover. Use a solid copper wire at least as large as the power supply wires. 3. Connect the ground wire to a grounded lead in a service panel, to a metal underground water pipe, to a metal well casing at least ten feet (3M) long, or to a ground electrode provided by the power company or the hydro authority. 4. Connect the power supply wires to the pressure switch as shown in Figure 4. 4

J212-24H Regulator EXPLODED VIEW 5 8 7 3 4 6 9 2E 2F 2D 1 2 2B 2C 2 1 229 1093 KEY PRT PRT NO. DESCRIPTION QTY. NUMBER Pressure Regulator Complete 1 Pkg. 107 1 Regulator Body w/seat 1 J112-14 1 Seat 1 J66-16 2 Diaphragm ssembly 1 J212-16B 2 Guide 1 J42-5 2B Stem 1 J62-9 2C Diaphragm 1 J20-16 2D Spring Follower 1 J43-31 2E Lockwasher 1 J43-23ZP 2F Nut 1/4-20 1 U36-36ZP 3 Spring 1 J24-13 4 Spring Guide 1 J61-5 5 Bonnet 1 J52-9 6 Capscrew 5/16-18 4 U30-60ZP 7 Hex Nut 5/16-18 1 U36-37ZP 8 djusting Screw 5/16-18 1 U30-665ZP 9 Pipe Plug 1/2 NPT 1 U78-59ZPS Compression Fitting 1/4 90 EL 1 U111-86T Tubing - Pressure Switch 1 U37-625P Not shown REPIR PRTS 5

1 2 15B 3 4 EXPLODED VIEW 6 20 21 22 23 10 3B 11 3 5 6 7 8 9 9 7 13 14 15 9B 11 16 11B 12 15 225 0993 17 19 18

REPIR PRTS KEY PRT NO. HMSD-1FL HMSE-1FL HMSF-1FL NO. DESCRIPTION W/KIT USED 3/4 HP 1 HP 1-1/2 HP 1 Motor, 60 Hz, 115/230V - Single Phase 1 700DH 700EH 700FH 1 Key - Shaft OH 2 U65-15SS U65-15SS U65-15SS 2 Water Slinger, -1F models only 1 C69-23 C69-23 C69-23 3 Seal Plate 1 L3-26 L3-26 L3-26 3 Stud - 3/8-16 x 1-13/16 Lg. 4 U30-35SS U30-35SS U30-35SS 3B Nut - 3/8-16 Hex Hd. 4 U36-38SS U36-38SS U36-38SS 4 Gasket - Seal Plate OH/SG 1 L20-43 L20-43 L20-43 5 Shaft Seal OH/SG 1 U109-267 U109-267 U109-267 6 Spring Holder Washer OH/SG 1 J24-11 J24-11 J24-11 7 Impeller OH 2 05-2PC 05-2PB 05-2P 8 Spacer - Impeller 1 J43-23 J43-23 J43-23 9 Diffuser ssembly w/wear Rings 1 01-45 01-45 01-45 9 Wear Ring OH (1) L23-9 L23-9 L23-9 9B Wear Ring OH (1) P23-19 P23-19 P23-19 10 Nut - Shaft OH 1 U36-175D U36-175D U36-175D 11 Diffuser Cover w/wear Ring 1 03-27 03-27 03-27 11 Wear Ring (1) L23-9 L23-9 L23-9 11B Capscrew - 1/4-20 x 3 Lg. 3 U30-528SS U30-528SS U30-528SS 12 Diffuser Ring OH/SG 1 L21-1 L21-1 L21-1 13 Pipe Plug - 1/2 NPT 1 U78-59ZPS U78-59ZPS U78-59ZPS 14 Pressure Gauge 1 U239-8 U239-8 U239-8 15 Pump Body 1 L76-36 L76-36 L76-36 15 Stud - 3/8-16 x 1-1/4 Lg. 8 U30-22SS U30-22SS U30-22SS 15B Nut - 3/8-16 Hex Hd. 3 U36-38SSW U36-38SSW U36-38SSW 16 Pipe Plug - 1/8 NPT 1 U78-56ZPS U78-56ZPS U78-56ZPS 17 ssembly 1 L262-4PS L262-4PS L262-4PS 18 Plug - 1/4 NPT 1 U78-941ZPV U78-941ZPV U78-941ZPV 19 Base 1 U4-5 U4-5 U4-5 19 Lockwasher - 3/8 2 U43-12ZP U43-12ZP U43-12ZP 19B Capscrew - 3/8-16 x 5/8 Lg. 2 U30-71ZP U30-71ZP U30-71ZP 20 Pressure Switch 1 U217-1216 U217-1216 U217-1217 20 Locknut - 1/2 1 U36-112ZP U36-112ZP U36-112ZP 20B Connector 1 L43-5C L43-5C L43-5C 21 Compression Fitting - Elbow - 1/4 1 U111-212T U111-212T U111-212T 22 Tube - Pressure Switch 1 U37-677P U37-677P U37-677P 23 Compression Fitting - Straight - 1/4 1 U111-100T U111-100T U111-100T Not shown. SERVICE KITS Seal and Gasket Kit 1 PP1625 PP1625 PP1625 Overhaul Kit 1 PP1631 PP1632 PP1633 NOTE: SG Included in Seal and Gasket Kit. OH Included in Overhaul Kit. 7

LIMITED WRRNTY Sta-Rite warrants to the original consumer of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period from the date of original installation or manufacture as noted. Product Water Systems Products jet pumps, small centrifugal pumps, submersible pumps and related accessories Con-ire Tanks Epoxy-Line Tanks Sump/Sewage/Effluent Products Warranty Period whichever occurs first: 1 year from date of original installation, or 2 years from date of manufacture 5 years from date of original installation 3 years from date of original installation 1 year from date of original installation, or 2 years from date of manufacture Our warranty will not apply to any product that has been subject to negligence, misapplication, improper installation or maintenance. In the event a three phase submersible motor is operated with single phase power through a phase converter, or if three-leg ambient compensated, extra-quick trip overload relays of recommended size are not used, our warranty is void. Buyer s only remedy and Sta-Rite s only duty is to repair or replace defective products (at Sta-Rite s choice). Buyer agrees to pay all labor and shipping charges associated with this warranty and to request warranty service through the installing dealer as soon as a problem is discovered. If warranty service is requested more than 30 days after the Warranty Period has ended, it will not be honored. ST-RITE SHLL NOT BE LIBLE FOR NY CONSEQUENTIL, INCIDENTL, OR CONTINGENT DMGES WHT- SOEVER. THE FOREGOING WRRNTIES RE EXCLUSIVE ND IN LIEU OF LL OTHER EXPRESS WRRNTIES. IMPLIED WRRNTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WRRNTIES OF MERCHNTBILITY ND FIT- NESS FOR PRTICULR PURPOSE, SHLL NOT EXTEND BEYOND THE WRRNTY PERIOD PROVIDED HEREIN. Certain states do not permit the exclusion or limitation of incidental or consequential damages or the placing of limitations on the duration of an implied warranty, therefore, the limitations or exclusions herein may not apply. This warranty sets forth specific legal rights and obligations, however, additional rights may exist, which may vary from state to state. Supersedes all previous publications. Sta-Rite Industries, Inc. 293 Wright St., Delavan, WI 53115 8