CCP2-FLR1-21_ flange-rod operating mechanism

Similar documents
Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

CM52 Network Protector with Arc Flash Reduction Module

Instruction Booklet IB E. Contents

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

Effective November 2016 Supersedes September 1998 (S )

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

Effective June 2016 New Issue

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

O & M Manual for the EATON Generator Ready Loadcenter

Two-way cable interlock kit for Magnum fixed circuit breakers

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

Advanced Test Equipment Rentals ATEC (2832)

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

TVSS Installation for RLCM/CHGENLC, RLCU, and CHGEN ATSs

Factory Authorized Mechanism Enhancement (FAME)

Effective March 2015 Supersedes S August 2012

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

3-way multi-family drawout cable interlock kit - type 32 - RF

Two-way cable interlock kit for Magnum drawout circuit breakers

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

High-voltage primary bushings installation instructions

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

Magnum Breaker Remote Racking Device (MRR1000)

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

! WARNING I.L D WARNING GENERAL INFORMATION

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

www. ElectricalPartManuals. com Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers

Flush Mount AIN ALPHA Meters. General. Hardware Kit

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

BSPA Type 1 and Type 2 surge protective devices

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

Reprogramming guide. Power Defense ICCB. Instructional Leaflet IL EN WARNING WARNING. Instructions apply to:

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

Removal/installation instructions for Series NRX (IZMX) drawout levering (racking) mechanism

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

Effective May 2017 Supersedes December 2004 (S )

Type NR oil switch installation and operation instructions

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

Effective November 2016 Supersedes February 2012 (S )

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

Digitrip Retrofit System for the Federal Pioneer 25-H(L)-2, 30-H(L)-2, 30-H(L)-3, and 30-3 Breakers

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

February 28 th, 2018 UPDATE: Important Product Safety Bulletin Immediate Action Required INSTRUCTIONS FOR FIELD RISK MITIGATION

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

COOPER POWER SERIES. KA146W5 single pole-mounting hanger; KA146W2 tank lifting windlass assembly and installation instructions. Reclosers MN280039EN

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

Effective December 2015 Supersedes September 2013

Magnum breaker remote racking device (MRR1000)

Specification made simple for selective coordination in a compact size

Effective May 2017 Supersedes January 2003 (S )

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

Digitrip Retrofit System for Allis-Chalmers LA-600 F Electrically Operated Fused Breakers

Compact Circuit Protector

Installation Instructions for R-Frame Circuit Breakers and Molded Case Switches

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

GM Specification Annual Test Data

Digitrip Retrofit System for Siemens-Allis RLX-1600 Breakers

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

37SCENE 46SCENE 79SCENE

Digitrip Retrofit System for BBC LKD 8 Breakers

Simple Electrically Operated Ground & Test Device For use in Type VCP-W Switchgear rated up to 15kV, 25 and 40kA UPPER TERMINAL SET VERSION

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2

38 kv Type VCPW-HD Simple Electrical Ground & Test Device (SEG&TD) lower terminal instruction booklet

Users Guide for Ac-sync

GM Specification Annual Test Data

Instructions for installation, operation, and maintenance of medium voltage VC-W MR2 (integral racking)

The easiest and fastest way to select and specify the right control circuit fuse

Model Numbers SAVI-NOTE75, SAVI-NOTE150

Heliporter. Owner s Manual. 150 Series. by Paravion Technology, Inc.

COOPER POWER SERIES. KA716L7001 adjustable control valve kit for Types L, E, 4E, V4E, and V4L reclosers installation and adjustment instructions

Digitrip Retrofit System for the General Electric AKR 6D/7D-30/50 and AKRT 6D/7D-50 Series Breakers

Air-Boss VP Intake Plenum

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

DANGER. See Wiring Diagrams on page 7 for illustrations of both internal and connection wiring diagrams. WARNING

DAP-625S and DAP-875S

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Transcription:

Installation manual 3A3747 Rev A Contents Description Page General information 1 Required tools 2 Hardware contents 2 Installation and adjustment 2-6 Flange drilling pattern 7 HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH MAY RESULT IN DEATH OR SERIOUS INJURY General information These instructions cover the installation and operation of the Bussmann series CCP2- FLR1-_ and CCP2-FLR2-_ flange rod operating mechanisms installed on 2- or 3-pole versions of the fused 30, 60 and 100 amp Compact Circuit Protector (CCP2) disconnect switches, and 3-pole versions of the non-fused 30, 60 and 100 amp Compact Circuit Disconnect (CCD2) disconnect switches. The flange rod handle mechanism provides an external means to operate the CCP2 and CCD2 switches. The standard handle is for NEMA 1, 3R, and 12 enclosures while the chrome handle version is for NEMA 4X enclosures. Using the CCP2-FLR1_ for CCP2 and CCD2 switches precludes using the optional PLC fuse monitor and auxiliary contacts. Full installation utilizes the operating handle, rod and assembled switch mechanism. Working on or near energized circuits poses a serious risk of electric shock. De-energize all circuits before installing or servicing this equipment and follow all prescribed safety procedures. Do not install or perform maintenance on equipment while it s energized. Death, severe personal injury or substantial property damage can result from contact with energized equipment. Always verify that no voltage is present, and prescribed safety and lockout/tagout procedures are followed. Eaton is not liable for the misapplication or mis-installation of this product. The user is cautioned to observe all recommendations, warnings and cautions relating to personnel and equipment safety, as well as all general and local health and safety laws, codes and procedures. The recommendations and information contained herein are based on experience and judgment, but should not be considered to be all-inclusive or covering every application or circumstance which may arise. If any questions arise, contact the Bussmann Division for further information or instructions.

Installation manual 3A3747 Rev A Required tools #1 phillips head screwdriver Needle nose pliers 5/16 open end wrench 7/16 open end wrench 9/16 open end wrench #8-32 tap and suitable drill bit Pliers Electric drill Hacksaw Metal file Before proceeding, please review flange rod operator kit contents to be sure all parts are included. If any are missing, please contact your local Bussmann series product representative. Part 1 Mount flange handle onto enclosure Refer to Fig. 1-1 and Fig. 1-2. Step 1. Place the handle mechanism with attached gasket over the enclosure cutout. (For cutout dimensions, refer to Fig. 4-1). Place the handle bracket on the inside as shown in Fig. 1-1, and insert the top 1/4-20 x 7/8 handle mechanism mounting screw and lock washer through the bracket and enclosure, and thread into the handle mechanism for a few turns, but not all the way. Step 2. Insert the bottom handle mechanism mounting screw and lock washer through the handle bracket and enclosure, an thread into the handle. Step 3. Securely tighten both mounting screws. Step 4. Mount door interlock hasp to handle using two #8-32 SEMS screws (see Fig. 1-1) and tighten. Hasp orientation may be modified per customer requirements and enclosures. Step 5. Attach the spring to the handle bracket and handle as shown in Fig. 1-2 after the threaded rod is installed in Part 3, Step 5. Step 6. Attach either the long or short door interlock hook onto the panel door s bracket. If door does not have a pre-installed interlock hook bracket, install the interlock bracket provided in the hardware. Step 7. Cycle handle ON and OFF, and check the door interlock operation. To cycle the mechanism, either close door or defeat door interlock lever. The flange handle mounting is now complete. Proceed to Part 2 Assemble operator mechanism onto switch and mount on panel. 4x - #8 x 3/4" Screws 4x - #8 Nuts 2 Operator mechanism hardware C 5x - 3.5 mm x 9mm thread forming screws 1x - 1/4" E-Clip 1x - Left support bracket A 3 B 1 1x - Mechanism frame 1x - Shaft/lever assembly 1x - Rear support bracket 1x - 21" Threaded shaft 2x - 1/4-28 x 5/8" Screws 2x - 1/4 Lock washers 1x - 1/4" Pin 1x - Hairpin clip Flange handle hardware 1x - 3/8" Locking nut 1x - 3/8" Threaded adjusting collar 1x - Handle bracket 2x - #8-32 x 11/32" Screws 1x - Door interlock hasp 1x - Spring 1x - 3/8 Rod adpater 1x - Interlock hook - Long 1x - Interlock hook - Short 1x - Interlock hook mounting bracket Fig. A Hardware contents 2

Installation manual 3A3747 Rev A Spring 1/4-20 x 7/8 mounting screws and lockwashers Handle bracket #8-32 SEMS screws Door interlock hasp Handle bracket Fig. 1-1. Assemble flange handle onto the enclosure using supplied mounting screws, lock washers and bracket as shown. Then install the door interlock hasp using the supplied screws, as shown. Tighten screws securely. Fig. 1-2. The spring attaches between the handle bracket and handle as shown. Install spring after adjusting threaded rod in Part 3, Step 5. 3

Installation manual 3A3747 Rev A Installation Part 2 Assemble operator mechanism onto switch and mount on panel Step 1. Test fit the shaft into right side of switch by inserting until fully seated (see Fig. 2-1). If shaft protrudes beyond the left side, mark and trim shaft accordingly with hacksaw. Remove burrs with metal file. Step 2. Place switch in ON position and insert shaft into the switch s right side until fully seated. Take care to align the shaft s lever so that it points to the lineside openings (see Fig. 2-2). Step 3. Secure mechanism frame to the switch s right side using three 3.5 mm x 9 mm thread forming phillips head screws placed in holes marked 1, 2 and 3. Torque to 12 lb-in (see Fig. 2-3). Step 4. Mount back and left side support brackets to mechanism frame: Back support bracket to mechanism frame using two #8-32 nuts and two #8-32 x 3/4 screws (see Fig. 2-4) and tighten. Left side support bracket to switch left side using the two 3.5 mm x 9 mm thread forming phillips head screws being careful to align the left side support bracket so that it is flush with the back support bracket. Torque to 12 lb-in (see Fig. 2-5) Step 5. Position switch against the enclosure s back panel so that the threaded rod, when installed, will be horizontal and at a right (90 ) angle to the switch lever pin (see Fig. 2-6). Insert switch shaft so lever is in this position relative to the switch handle position. Fig. 2-2. Align shaft lever with switch handle position. Step 5a. With the switch in position, mark the enclosure s back panel for two holes corresponding to the holes in the left support bracket. Next, drill and tap two #8-32 holes in the enclosure s back panel (see Fig. 2-7). Step 6. Secure the switch and operator assembly to the enclosure s panel using two #8-32 screws and tighten. Note: Two extra #8-32 nuts are provided should it be desirable to install them on these two #8-32 screws. The switch/mechanism assembly and installation is now complete. Proceed to Part 3 Threaded rod installation and adjustment. Secure mechanism frame to switch using three #3.5 mm x 9mm thread forming phillips head screws Fig. 2-3. Secure mechanism frame to switch using three 3.5 mm x 9 mm thread forming phillips head screws in holes marked 1, 2 and 3. Install back support bracket using two #8-32 x 3/4 screws and nuts Insert shaft into right side of switch until fully seated. If shaft protrudes on the other side, mark length and trim to fit flush. Fig. 2-4. Mount back support bracket to mechanism frame. Fig. 2-1. Test fit shaft. 4

Installation manual 3A3747 Rev A Install left side support bracket using two 3.5 mm x 9mm thread forming phillips head screws Before tightening screws, be sure left side support bracket is flush with and not distorting back side support bracket Fig. 2-5. Mount left side support bracket to switch. 3/8 Threaded adjusting collar 3/8 Lock nut Threaded shaft Switch lever pin and E-Clip Rod adapter 1/4 Pin and hairpin clip 90 90 Fig. 2-6. For proper alignment, position switch and operator assembly against panel back wall so that the threaded shaft is at right angles vertically and horizontally. After positioning switch, mark, drill and tap two holes for #8-32 x 3/4 screws Fig. 2-7. Mark, drill and tap two #8-32 holes and secure switch/ mechanism to back panel wall using two #8-32 screws. Install the two extra #8-32 nuts on the back of panel if extra strength is desired. 5

Installation manual 3A3747 Rev A Installation Part 3 Threaded rod installation and adjustment Step 1. Install rod adapter onto the flange handle toggle and secure using the 1/4 pin and hairpin clip (see Fig. 3-1). Step 2. Place both the switch and flange handle in the OFF position and test fit the threaded shaft for length (see Fig. 3-2). Note: the threaded shaft length, when cut, needs to be long enough so that the 3/8 threaded adjusting collar will engage both the threaded shaft and rod adapter for a minimum of 3/8 on both ends. Step 3. Cut threaded shaft to length, file off any burrs. Thread on the 3/8 locking nut and 3/8 threaded adjusting collar. Next thread the adjusting collar onto the rod adapter and adjust the total length so that the threaded rod end will slip onto the switch lever pin (see Fig. 3-2). Step 4. Test the flange handle s operation by cycling ON and OFF. If operating satisfactorily, proceed to Step 5. If further adjustment is needed, disengage the threaded rod from the switch s lever and lengthen or shorten until proper flange handle operation is obtained, then proceed to Step 5. Step 5. Secure threaded rod to switch lever pin using the 1/4 E-Clip. Tighten the 3/8 locking nut to prevent the adjusting collar from rotating. Install spring between handle bracket and handle as shown in Fig. 3-2. Rod adapter Hairpin clip 1/4 Pin The installation is now complete. Fig. 3-1. Install rod adapter using 1/4 pin and secure with hairpin clip. 3/8 minimum thread engagement between rod adapter, threaded rod and adjusting collar 3/8 Lock nut Adjusting collar Threaded shaft Rod adapter Secure threaded rod to switch lever pin using 1/4 E-Clip Fig. 3-2. Test fit threaded rod, mark and cut to length. Next install the 3/8 lock nut and adjusting collar. 6

Installation manual 3A3747 Rev A Installation Part 4 Custom flange handle mounting If an enclosure that does not have provisions for mounting the flange handle, below (see Fig. 4-1) are the dimensions for making the necessary cutouts and mounting the door interlock blade. 2.75 min inside 1.9 Upper hole Datum R = 0.25 0.62 Datum 1.62 min 2 clearance holes in flange for 1/4-20 screws 0.5 ± 0.01 0.56 ± 0.01 B 3.44 ± 0.01 4.69 ± 0.005 The instructions for installation, testing, maintenance, or repair herein are provided for the use of the product in general commercial applications and may not be appropriate for use in nuclear applications. These instructions are published solely for information purposes and should not be considered all-inclusive. If further information is required, you should consult an authorized Bussmann series sales representative. The sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between the parties. This literature is not intended to and does not enlarge or add to any such contract. The sole source governing the rights and remedies of anyone purchasing this equipment is the contract between the purchaser and the Bussmann division. NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OR WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE, ARE MADE REGARDING THE INFORMATION, RECOMMENDATIONS, AND DESCRIPTIONS CONTAINED HEREIN. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and description contained herein. 4.0 0.25 2.0 1.5 5.75 min Fig. 4-1. Flange drilling pattern for handle and interlock blade mounting. 7

Installation manual 3A3747 Rev A Notes Eaton 1000 Eaton Boulevard Cleveland, OH 44122 Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States 2018 Eaton All Rights Reserved Printed in USA Publication No. 3A3747 August 2018 Eaton and Bussmann are valuable trademarks of Eaton in the U.S. and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. ANSI is a registered trademark of the American National Standards Association IEEE is a registered trademark of the Institute of Electrical and Electronics Engineers NEMA is a registered trademark of the National Electrical Mfgrs. Association NFPA is a registered trademark of the National Fire Protection Association UL is a registered trademark of the Underwriters Laboratories, Inc. 8