CABINET & TWIN FANS FOR INDUSTRIAL / COMMERCIAL USE "ACFS" - Quiet Duct Centrifugal - Single Fan "DMTSQ" - Quiet Duct Centrifugal - Twin Fan "RMS" - Roof Centrifugal - Single Fan "RMTS" - Roof Centrifugal - Twin Fan "SMX" - In-Line Mixed Flow "PTE" & "RTE" - Belt Driven Twin Uniclass L7534 Manufacture controlled to ISO91
Page 2 DMTSQ ACFS - ACOUSTIC - PERFORMANCE CABINET CURVES FANS - GENERAL ACFS Range - Super-Silent Cabinet - Single Fan 7 models from 125 to mm Airflow from 392 to 3974 m 3 /hr (.19 to 1.14 m 3 /sec) Galvanised steel cabinet with acoustic lining Acoustic lining 25mm thick, high density, non-toxic and Class "O" flame retardant Speed controllable Auto reset, thermal cut-out protection Integral mounting points for easy installation May be mounted vertically or horizontally (with access either on top or bottom - to be confirmed with order) Motor/impeller assembly mounted on removable plate for easy maintenance and cleaning Fans are pre-wired to a single external terminal box to ensure simple and quick installation Extremely low noise levels air temperature 4 o C All fans single phase, 23v Twin fan version also available ACFS - ACOUSTIC CABINET FANS - TECHNICAL DATA Size Power Kw FLC amps SC amps Speed rpm Speed Controller Sound Level db A at 3m Sound Power Levels db Mid Octave Bands (Hz) ins cm Electronic Transformer 63 125 25 1 8 ACFS125 5 12.135.63 1.6 VC1 VC1AM 28 66 64 62 59 56 54 55 52 ACFS15 6 15.135.63 1.6 VC1 VC1AM 28 66 64 62 59 56 54 55 52 ACFS 8 2.19.85 2.2 125 VC1 VC1AM 32 72 67 68 66 69 63 61 59 ACFS25 1 25.37 3.6 11.2 145 VC4M VC4AM 37 77 73 71 72 74 71 69 64 ACFS315 12 31.37 3.85 12 1 VC4M VC4AM 4 73 75 76 76 76 73 69 61 ACFS 16 4.55 5.1 12.8 1 VC7M VC7AM 42 77 77 78 76 78 75 73 66 ACFS 2 5.59 6.8 17. 88 VC7M VC7AM 42 77 77 78 76 78 75 73 66 ACFS - ACOUSTIC CABINET FANS - PERFORMANCE m 3 /hr m 3 /sec m 3 /sec at Pa 25 5 75 1 15 25 3 35 45 ACFS125 392.19.19.17.16.13.1.9.77.59.28 - - - - SFP 1.4 1.4 1.4 1.6 1.8 1.17 1.33 1.69 3.43 - - - - ACFS15 389.18.18.16.14.11.97.88.75.57.28 - - - - SFP 1.4 1.4 1.5 1.8 1.11 1.19 1.36 1.72 3.43 - - - - ACFS 832.231.231.228.222.215.27.177.135.75.15 - - - - SFP.81.81.82.85.87.97 1.19 1.95 9.54 - - - - ACFS25 2657.738.738.74.667.625.58.481.283.75 - - - - - SFP 1.33 1.37 1.41 1.46 1.51 1.7 2.56 7.5 - - - - - ACFS315 2398.666 - - - - - - -.655.583.241.138.61 - SFP - - - - - - - 1.24 1.28 2.51 4.45 1.3 - ACFS 3499.972 - - - - - -.911.839.718.262.133 - - SFP - - - - - - 1.23 1.18 1.22 2.6 4.9 - - ACFS 3974 1.14 - - - - - 1.12 1.62 1.23.974.879.472.285.178 SFP - - - - - 1.46 1.38 1.34 1.31 1.29 1.77 2.74 4.69
Page 3 DMTSQ ACFS - PERFORMANCE - CURVES CURVES & DIMENSIONS 55 45 External Pressure (Pa) 35 3 25 315 15 1 15 25 5 125.1.2.3.4.5.6.7.8.9 1. 1.1 1.2 Duty (m 3 /sec) ACFS - ACOUSTIC CABINET FANS - DIMENSIONS (mm) A B C D Kg ACFS125 375 24 125 13 ACFS15 375 24 15 13 ACFS 475 31 425 15 ACFS25 575 44 25 31 ACFS315 575 55 315 4 ACFS 625 55 41 ACFS 75 545 6 51
Page 4 DMTSQ - PERFORMANCE DUCT MOUNTED CURVES TWIN FAN - GENERAL DMTSQ Range - Super-Silent Cabinet - Twin Fans 7 models from 125 to mm Airflow from 392 to 3974 m 3 /hr (.19 to 1.14 m 3 /sec) Galvanised steel cabinet with acoustic lining Acoustic lining 25mm thick, high density, non-toxic and Class "O" flame retardant The motor/impeller assembly is mounted on a removable plate to facilitate easy mainte nance and cleaning May be mounted in multiple orientations (confirm with sales at time or ordering) l Fitted with back-draught shutters Fans are pre-wired to a single external terminal box to ensure simple and quick installation Auto reset, thermal cut-out protection Extremely low noise levels air temperature 4 o C Auto changeover controllers with variable duty share available All fans single phase, 23v Single fan version available DMTSQ - DUCT MOUNTED TWIN FANS - TECHNICAL DATA DMTSQ - DUCT MOUNTED TWIN FANS - PERFORMANCE Auto Changeover Controller Sound Power Levels db Sound Size Power FLC SC Speed Level Manual Auto Mid Octave Bands (Hz) Kw amps amps rpm db A Duty Duty at 3m ins cm Share Share 63 125 25 1 8 DMTSQ125 5 12.135.63 1.6 VAC1E VAC2E 28 66 64 62 59 56 54 55 52 DMTSQ15 6 15.135.63 1.6 VAC1E VAC2E 28 66 64 62 59 56 54 55 52 DMTSQ 8 2.19.85 2.2 125 VAC1E VAC2E 32 72 67 68 66 69 63 61 59 DMTSQ25 1 25.37 3.6 11.2 145 VAC1E VAC2E 37 77 73 71 72 74 71 69 64 DMTSQ315 12 31.37 3.85 12. 1 VAC1E VAC2E 4 73 75 76 76 76 73 69 61 DMTSQ 16 4.55 5.1 12.8 1 VAC1E VAC2E 42 77 77 78 76 78 75 73 66 DMTSQ 2 5.55 6.8 17 155 VAC1E VAC2E 42 72 77 78 76 78 75 73 66 m 3 /hr m 3 /sec m 3 /sec at Pa 25 5 75 1 15 25 3 35 45 DMTSQ125 392.19.19.17.16.13.1.9.77.59.28 - - - - SFP 1.4 1.4 1.4 1.6 1.8 1.17 1.33 1.69 3.5 - - - - DMTSQ15 389.18.18.16.14.11.97.88.75.57.28 - - - - SFP 1.4 1.4 1.5 1.8 1.11 1.19 1.36 1.72 3.5 - - - - DMTSQ 832.231.231.228.222.215.27.177.135.75.15 - - - - SFP.81.81.82.85.87.97 1.19 1.95 9.54 - - - - DMTSQ25 2657.738.738.74.667.625.58.481.283.75 - - - - - SFP 1.33 1.37 1.41 1.46 1.51 1.7 2.56 7.5 - - - - - DMTSQ315 2398.666 - - - - - - -.655.583.241.138.61 - SFP - - - - - - - 1.24 1.28 2.51 4.45 1.3 - DMTSQ 3499.972 - - - - - -.911.839.718.262.133 - - SFP - - - - - - 1.23 1.18 1.22 2.6 4.9 - - DMTSQ 3974 1.14 - - - - - 1.12 1.62 1.23.974.879.472.285.178 SFP - - - - - 1.46 1.38 1.34 1.31 1.29 1.77 2.74 4.69
Page 5 DMTSQ - PERFORMANCE CURVES DMTSQ - PERFORMANCE CURVES & DIMENSIONS 55 45 External Pressure (Pa) 35 3 25 315 15 1 15 25 5 125.1.2.3.4.5.6.7.8.9 1. 1.1 1.2 Duty (m 3 /sec) DMTSQ - DUCT MOUNTED TWIN FANS - DIMENSIONS (mm) A B C D Kg DMTSQ125 55 31 125 2 DMTSQ15 55 31 15 2 DMTSQ 8 31 22 DMTSQ25 15 425 65 25 52 DMTSQ315 15 475 65 315 7 DMTSQ 15 475 65 72 DMTSQ 125 525 75 85
Page 6 RMS - ROOF MOUNTED SINGLE FAN - GENERAL RMS Range 7 models from 125 to mm Airflow from 389 to 3974 m 3 /hr (.18 to 1.14m 3 /sec) Single skinned plastisol coated steel cabinet Fully weatherproofed Birdmesh on cowl outlet Air inlet through rear or bottom panel (to be confirmed with order) Auto reset, thermal cut-out protection air temperature 4 o C All fans single phase, 23v Twin fan version available RMS ROOF MOUNTED SINGLE FAN - TECHNICAL DATA Speed Controller Sound Power Levels db Size Current Mid Octave Bands (Hz) Power SC Speed Kw amps rpm Electroniformer amps Trans- ins cm 63 125 25 1 8 RMS125 5 12.135.63 1.6 VC1 VC1AM 66 69 62 59 56 54 55 52 RMS15 6 15.135.63 1.6 VC1 VC1AM 66 69 62 59 56 54 55 52 RMS 8 2.19.85 2.2 125 VC1 VC1AM 72 67 68 66 69 63 61 59 RMS25 1 25.37 3.6 11.2 145 VC4M VC4AM 77 73 71 72 78 71 69 64 RMS315 12 31.37 3.85 12. 1 VC4M VC4AM 73 75 76 76 76 73 69 61 RMS 16 4.55 5.1 12.8 1 VC7M VC7AM 77 77 78 76 78 75 73 66 RMSM 2 5.55 6.8 17 155 VC7M VC7AM 77 77 78 76 78 75 73 66 RMS - ROOF MOUNTED SINGLE FAN - PERFORMANCE m 3 /hr m 3 /sec m 3 /sec at Pa 25 5 75 1 15 25 3 35 45 RMS125 389.18.18.17.15.12.98.89.76.57.28 - - - - SFP 1.4 1.4 1.4 1.7 1.1 1.19 1.35 1.74 3.45 - - - - RMS15 385.17.17.15.13..99.95.86.73.55.22 - - - - SFP 1.4 1.4 1.5 1.8 1.11 1.19 1.36 1.72 3.5 - - - - RMS 817.227.227.22.215.26.197.167.125.72.14 - - - - SFP.81.82.85.87.9 1.2 1.27 1.98 9.55 - - - - RMS25 2164.61.61.572.541.511.471.368.25.72 - - - - - SFP 1.49 1.53 1.58 1.63 1.72 2.2 3.33 7.5 - - - - - RMS315 2398.666 - - - - -.654.69.517.334.212.13.6 - SFP - - - - - 1.24 1.26 1.37 1.9 2.91 4.69 1.37 - RMS 3499.972 - - -.949.923.87.83.78.439.242.128 - - SFP - - - 1.27 1.24 1.19 1.18 1.23 1.64 2.89 5.5 - - RMSM 3974 1.14 - - 1.1 1.82 1.65 1.3.992.938.842.579.412.269.173 SFP - - 1.45 1.41 1.37 1.35 1.32 1.3 1.29 1.54 1.99 2.94 4.79
Page 7 RMS - PERFORMANCE CURVES & DIMENSIONS 55 45 External Pressure (Pa) 35 3 25 315 15 1 125 15 25 5.1.2.3.4.5.6.7.8.9 1. 1.1 1.2 Duty (m 3 /sec) RMS - ACOUSTIC CABINET FANS - DIMENSIONS (mm) A B C D E Kg RMS125 325 275 3 125 15 2 RMS15 325 275 3 15 15 2 RMS 425 375 425 15 28 RMS25 425 375 425 25 28 RMS315 575 45 315 25 35 RMS 8 475 55 25 37 RMSM 875 58 65 25 49
Page 8 RMTS - ROOF MOUNTED TWIN FANS RMTS Range 7 models from 125 to mm Airflow from 392 to 3974 m 3 /hr (.19 to 1.14m 3 /sec) Single skinned plastisol coated steel cabinet Fully weatherproofed Birdmesh on cowl outlet Air inlet through rear or bottom panel (to be confirmed with order) Fitted back-draught shutters Auto reset, thermal cut-out protection air temperature 4 o C Auto changeover controllers with variable duty share available All fans single phase, 23v Single fan version available RMTS - ROOF MOUNTED TWIN FANS - TECHNICAL DATA Auto Changeover Controller Sound Power Levels db Size Current Manual Auto Con- Mid Octave Bands (Hz) Speed Power SC Speed Kw amps rpm amps Duty Duty troller ins cm Share Share 63 125 25 1 8 RMTS125 5 12.135.63 1.6 VAC1E VAC2E QE1.5 66 69 62 59 56 54 55 52 RMTS15 6 15.135.63 1.6 VAC1E VAC2E QE1.5 66 69 62 59 56 54 55 52 RMTS 8 2.19.85 2.2 125 VAC1E VAC2E QE1.5 72 67 68 66 69 63 61 59 RMTS25 1 25.37 3.6 11.2 145 VAC1E VAC2E QE6 77 73 71 72 78 71 69 64 RMTS315 12 31.37 3.85 12. 1 VAC1E VAC2E QE6 73 75 76 76 76 73 69 61 RMTS 16 4.55 5.1 12.8 1 VAC1E VAC2E QE6 77 77 78 76 78 75 73 66 RMTS 2 5.55 6.6 17 155 VAC1E VAC2E QE8 77 77 78 76 78 75 73 66 RMTS - ROOF MOUNTED TWIN FANS - PERFORMANCE m 3 /hr m 3 /sec m 3 /sec at Pa 25 5 75 1 15 25 3 35 45 RMTS125 392.19.19.17.16.13.99.9.77.59.29 - - - - SFP 1.4 1.4 1.4 1.6 1.1 1.18 1.33 1.68 3.29 - - - - RMTS15 389.18.18.16.14.11.96.87.74.57.28 - - - - SFP 1.4 1.4 1.5 1.8 1.12 1.21 1.38 1.74 3.43 - - - - RMTS 828.23.23.226.221.214.25.174.132.74.14 - - - - SFP.81.81.82.85.88.99 1.21 1.97 9.89 - - - - RMTS25 2272.631.631.657.62.581.542.436.245.75 - - - - - SFP 1.38 1.42 1.46 1.51 1.57 1.81 2.89 7.5 - - - - - RMTS31 238.661 - - - - - -.661.624.483.228.135.61 - SFP - - - - - - 1.23 1.25 1.43 2.66 4.53 1.28 - RMTS 3348.93 - - - - -.93.869.788.63.255.131 - - SFP - - - - - 1.25 1.19 1.18 1.28 2.7 4.93 - - RMTS 3974 1.14 - - 1.1 1.82 1.65 1.3.992.938.842.579.412.269.173 SFP - - 1.45 1.41 1.37 1.35 1.32 1.3 1.29 1.54 1.99 2.94 4.79
Page 9 RMTS - PERFORMANCE CURVES & DIMENSIONS 55 45 External Pressure (Pa) 35 3 25 315 15 125 25 1 15 5.1.2.3.4.5.6.7.8.9 1. 1.1 1.2 Duty (m 3 /sec) RMTS - ACOUSTIC CABINET FANS - DIMENSIONS (mm) A B C D E Kg RMTS125 65 375 125 15 19 RMTS15 65 375 15 15 19 RMTS 8 375 175 21 RMTS25 95 45 25 45 RMTS315 1 58 65 315 51 RMTS 115 58 65 25 56 RMTS 125 58 7 3 84
Page 1 SMX - SQUARE CASED MIXED FLOW FANS SMX Range 5 sizes - casings from 45 to 7 mm square Airflow to 4.17m 3 /sec - pressure to 6 Pa Robust construction with casing in 1mm thick galvanised sheet steel Motor is external rotor type, 4 pole, single or three phase (other options available) Connections for thermal cut-out protection Integral motor/impeller assembly with impeller in polyamide for sizes 35-45 or aluminium for sizes and 56 Flanged connection for quick and simple installation Unique, integral terminal box allows for electrical connections on two sides of casing to ensure flexibility during installation Suitable for operation in air temperatures between -1ºC and +6ºC (s SMX35/4/1, SMX/4/1 and SMX45/4/1). s SMX/4/1 and SMX56/4/3 suitable for between -1ºC and +4ºC Motor fan assembly IP54 rated External models available to order SMX - SQUARE CASED MIXED FLOW FANS - TECHNICAL DATA Size Power Kw Current amps SC amps Speed rpm Transformer Sound Level db A at 3m Sound Power Levels db Mid Octave Bands (Hz) ins cm 63 125 25 1 8 SMX354M 14 35.31 1.35 3.7 139 VC1AM 53 77 76 74 68 64 62 56 5 SMXM 16 4.46 2. 5. 128 VC4AM 59 83 82 8 74 7 68 62 56 SMX454M 18 45.91 4.4 9.2 126 VC7AM 61 85 84 82 76 72 7 64 58 SMX54M 2 5 1.45 6.1 15. 131 VC7AM 62 86 85 83 77 73 71 65 59 SMX564T 22 56 2.4 4.3 2. 135 VC7AT 69 93 92 9 84 8 78 72 66 SMX - SQUARE CASED MIXED FLOW FANS - PERFORMANCE m 3 /hr cfm m 3 /sec at Pa 5 1 15 25 3 35 45 55 6 SMX354M 3312 1954.92.81.67.47.22 - - - - - - - - SMXM 4716 2782 1.31 1.17 1.6.89.69.52.14 - - - - - - SMX454M 7 4248 2. 1.88 1.79 1.61 1.48 1.25 1.2.61 - - - - - SMX54M 9612 5671 2.67 2.56 2.35 2.2 2. 1.81 1.59 1.28.94.56.11 - - SMX564T 1512 8857 4.17 3.96 3.75 3.51 3.23 2.95 2.67 2.43 2.12 1.8 1.41.83.28
Page 11 SMX - PERFORMANCE CURVES & DIMENSIONS 6 564T External Pressure (Pa) 3 44M 54M 1 354M 454M.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 Duty (m 3 /sec) SMX - MIXED FLOW FANS - DIMENSIONS (mm) A B C Kg SMX354M 45 18 SMXM 435 55 26 SMX454M 55 55 62 35 SMX54M 535 661 731 45 SMX564T 57 7 77 54 Web: www.vectaire.co.uk
Page 12 PTE - INTERNAL BELT DRIVEN TWIN FANS PTE Range 17 models Airflow to 2.m 3 /sec l 25mm double skinned galvanised steel case air temperature 4 o C Auto changeover controllers with variable duty share available For horizontal mounting only (contact AVT for information re vertical mounting) External models available PTE - BELT DRIVEN TWIN FANS - DIMENSIONS (mm) A B C D E F Kg PTE7 1 9 45 95 1 135 PTE8 115 55 9 1 1 16 PTE9 1 65 9 6 1125 1 196 PTE1 135 75 9 7 125 1 23 PTE11 145 9 1 85 145 1 275
Page 13 PTE and "RTE"- PERFORMANCE CURVES 6 External Pressure (Pa) 3 1.5.6.7.8.9 1. 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2. Duty (m 3 /sec) PTE - ATTENUATOR PRESSURE DROPS 35 3 TE11 25 Pressure Drop (Pa) 2 15 TE8 TE9 TE1 1 TE7 5.5.6.7.8.9 1. 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2. Length Air volume (m 3 /sec) Mid Octave Band Attenuation/Hz 63 125 25 1 8 9mm 5 9 16 3 39 39 31 26 1mm 6 12 23 4 51 51 41 29 1mm 8 15 26 43 53 53 45 32 18mm 9 17 3 47 55 55 49 36 21mm 11 2 35 55 55 55 55 43 2mm 12 23 4 55 55 55 55 47
Page 14 RTE - ROOF MOUNTED BELT DRIVEN TWIN FANS RTE Range 17 models Airflow to 2.m 3 /sec Single skinned galvanised steel case with plastisol finish (double skinned option) Fully weatherproofed air temperature 4 o C Auto changeover controllers with variable duty share available Internal models available RTE - BELT DRIVEN TWIN FANS - DIMENSIONS (mm)s A B C D E F Kg RTE7 11 55 9 45 9 1 23 RTE8 125 6 9 1 1 275 RTE9 13 7 9 6 15 1 335 RTE1 145 8 9 7 1125 1 38 RTE11 155 8 1 7 1175 1 425
Page 15 "RTE"- ATTENUATOR PRESSURE DROPS 5 45 4 TE11 35 3 Pressure Drop (Pa) 25 2 15 TE8 TE9 TE1 1 TE7 5.5.6.7.8.9 1. 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2. Air volume (m 3 /sec) Length Mid Octave Band Attenuation/Hz 63 125 25 1 8 9mm 5 9 16 3 39 39 31 26 1mm 6 12 23 4 51 51 41 29 1mm 8 15 26 43 53 53 45 32 18mm 9 17 3 47 55 55 49 36 21mm 11 2 35 55 55 55 55 43 2mm 12 23 4 55 55 55 55 47 35 RTE - COWL PRESSURE DROPS 3 25 TE8 2 TE11 Pressure Drop (Pa) 15 1 TE7 TE9 TE1 5.5.6.7.8.9 1. 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2. Air volume (m 3 /sec)
Other ventilation products Commercial/Industrial Air Handling Commercial/Industrial Heat Recovery Long Cased Axial Fans Plate Axial Fans Roof Mounted Axial Fans Centrifugal Roof Fans Residential Heat Recovery - DC Motors MicroboxSlimline Fans - DC Motor Option In-Line Fans Residential Heat Recovery - DC Motors Built-in Wall Fans Vectaire Ltd Lincoln Road Cressex Business Park High Wycombe Buckinghamshire HP12 3RH Vectaire Ltd reserves the right to alter specifications as part of its policy of continuous development Window Wall Fans Sept211/C&T E & O.E