Glass Filler Plumbing Kit Part Number 96852CA

Similar documents
Halsey Taylor Owners Manual

Halsey Taylor Owners Manual

Halsey Taylor Owners Manual

Installation/Care/Use Manual

Installation/Care/Use Manual

LZS8WS EZH2O BOTTLE FILLING STATION & COOLER

Halsey Taylor Owners Manual

Performance Inlet Manifold

FILTER KIT. HWF172 Watersentry VII Kit (Lead, Aesthetic Chlorine Taste & Odor & Particulate Class I Reduction) FOR COMMERCIAL USE ONLY

High Security Indoor Public Bike Pump Service Manual

A171 Series Barrier Free, Wall Mounted Fountain

RT1 DUAL OUTLET SLIP-ON EXHAUST HONDA CBR600RR Rev B

Air Conditioner for M915 A0/A1 Truck

1. Seat 6. Side cover 11. Fuel pump retainer. 4. Mud guard 9. Fuel pump gasket : Do not reuse.

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Installation Guide. 3-Way/2-Way Transfer Valve E

Installation/Care/Use Manual

INSTALLATION INSTRUCTIONS

RTX 2000 Thomas Compressor TG-550 Graco PN

IceZone -X Installation Instructions for Scotsman HID312 Meridian Ice and Water Dispensers

Please read BOTH these Installation Instructions and the General Information sheet prior to installing or operating this equipment.

Service Bulletin. HIITMill (X) Brake Lever Drift

Please read BOTH these Installation Instructions and the General Instructions prior to installing or operating this equipment.

Installation For Service Only

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Automated Steering Hydraulic Installation Kit

INSTALLATION INSTRUCTIONS

Installation Instructions

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION GUIDE

IceZone X Installation Instructions for Hoshizaki DCM-270 Ice and Water Dispensers

INSTALLATION INSTRUCTIONS FUEL RAIL

BEFORE BEGINNING INSTALLATION

Installation Instructions

INSTALLATION INSTRUCTIONS

TOYOTA RAV TRAILER WIRE HARNESS Preparation

Owner smanual. Banks TorqueTube System. Jeep 4.0L I-6 Models including: '00-06 Wrangler '00-01 Cherokee '99-01 Grand Cherokee

ADVANTAGE Annual Preventive Maintenance Instructions

WARNING. BX Honda Civic (Includes Turbo) Installation Instructions

Toyota Corolla Interior Light Upgrade

Step 4: Remove rear fuel line banjo bolt. Be sure to catch copper washer between pump and front of the rear fuel line.

INSTALLATION INSTRUCTIONS

Installation and Maintenance Instructions

Installation Instructions

Fits AGCO, Challenger, & Massey Ferguson Tractor Models:

Operating Manual for Hands-Free Wall Mounted Sinks Models 607D and 607D-0.5

REF QTY PART DESCRIPTION PART NUMBER

WATER COOLERS I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S. BF2 Series Bottle Filler, Sensor Operated

Operating Manual for Hands-Free Wall Mounted Sinks Models 504 and

Owner smanual. Banks torquetube System. Jeep 4.0L I-6 models including: Wrangler Cherokee Grand Cherokee Comanche

A152/FG-BF4 Series Rounded Box Barrier-Free Wall Mount Bi-Level Drinking Fountain with Sensor Activated Bottle Filler

Cylinder and Valve: AirHawk II Air Mask

WARNING. BX Saturn Vue and Redline Chevy Captiva (All Models) Installation Instructions

Owner smanual. Banks TorqueTube System. Jeep 2.5L 4-Cylinder '91-02 Wrangler. with Installation Instructions THIS MANUAL IS FOR USE WITH SYSTEM 51316

* * Inside Toyota Avalon. Tools Required IMPORTANT

BX2616. Please read BOTH these Installation Instructions and the General Towing Instructions before attempting to install or operate this equipment.

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION GUIDE

Carousel Unit User Manual Replacing the Check Stand Motor

Installation Kitchen Faucet Filtration System Instructions GXK285JBL

Owner smanual. Banks TorqueTube System With Optional Headpipe Assembly

Volvo P1 Air Intake. ELEVATE Turbo Intake Pipe. MAF Sensor. Inlet Manifold. Air Filter Housing. ECU Cover

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

2016+ NISSAN TITAN XD

Binks MODELS & AGITATOR DRIVE UNITS

Surface Mounted Bottle Fillers

INSTALLATION INSTRUCTIONS SINGLE, DOUBLE, TRIPLE AND QUADRUPLE STATION SENSOR OPERATED SOLID SURFACE AND BIO-DECK LAVATORY SYSTEMS ELC-41000

LAWN SPRINKLER, IRRIGATION PUMP

Automated Steering Kit Installation Guide

WARNING NOTICE CAUTION ASSEMBLY INSTRUCTIONS

Service Sheet SSJ0452P. J0452 Coupler with Pump API Coupler

AA-75CF Portable Compressor NSN:

ETF-600 Sensor Operated Lavatory Faucet

INSTALLATION INSTRUCTIONS

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION GUIDE

LGT-306L / LB Club Car Precedent LED Light Bar Bumper Kit Installation Instructions

Installation Instructions

CAFS Air Compressor Service Parts List Models 100-D, 120-D, 150-D, 200-D

WARNING. BX Nissan Sentra S/SV/SR/SL Installation Instructions

SCION FR-S FOG LIGHTS

MFH-5398 Block Only Fresh Water Cooling Kit Instructions

Installation Instructions:

model 2000SN FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS Recessed Wall-Mount Bottle Filling Station

Audi-Larm TM Audible Alarm: AirHawk II Air Mask

ROUSH Active IO Exhaust. Installation Instructions P/N: (R LITE) Fastback GT Convertible GT V8

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

WARNING Pontiac G6 GT BX3235. Serial Number. Installation Instructions

GENERAL INSTALLATION MANUAL

Torqueflite Trans-Scat Kit

MFH-5456 On-Engine Block & Manifold Freshwater Cooling Kit for Mercury Remanufacturing 357 Engines Instructions

CAMRY STRIP LED DRL TOYOTA Part Number: Accessory Code: LDRS10. PIO / DIO Rev. A 02/26/13. Doc

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS.

Installation Instructions

BX Dodge Nitro Jeep Liberty Limited 4x4 Installation Instructions

BLACKBIRD INSTALLATION SUPPLEMENT

Toyota Venza Interior Light Upgrade

INSTALLATION INSTRUCTIONS PART NUMBER AEM C (GUN METAL GRAY FINISH)

Installation Guide. Single-Control Bath and Shower Trim A K K K 12021

Installation Guide D. Three-Way/Two-Way Transfer Valve P29513, P29514

LEAK TEST PROCEDURE MRT4-DC LIFTERS SINGLE VACUUM SYSTEMS TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE

2005 Dodge Grand Caravan Installation Instructions

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Transcription:

Glass Filler Plumbing Kit Part Number 96852C This plumbing kit is designed to be used with Halsey Taylor HTVZ, HC, S-Series, SCWT, SW and WM Models manufactured after December 1998. Warning To avoid risk of electrical shock, personal injury or death, disconnect from electrical power supply and shutoff water supply before installing this plumbing kit. Caution To avoid property damage, personal injury and voiding your warranty: Have this kit installed by an authorized person. (Installation person should be familiar with water cooler plumbing, refrigeration systems and general plumbing practices.) Install this kit into one of the Halsey Taylor models listed above. Make sure you read, understand and follow the instructions. Wear hand and arm protection. Use caution when working inside the water cooler. Edges inside the water cooler can be sharp. Wear eye safety goggles. Required Tools To install this kit the following tools are required: Phillips Screwdriver Needle Nose Pliers 1/4 and 5/16 Nut or Socket Driver Tubing Cutter (Mini) 11/16 (.687 ) diameter hole punch or drill bit. Large adjustable wrench. Parts List Refer to the illustration to make sure you receive all plumbing kit parts. If any parts are missing contact your Halsey Taylor distributor. Depending on model, not all parts are required. ITEM NO. PRT NO. DESCRIPTION 2 1 3 4 5 6 7 1 2 3 4 5 6 7 56092C 15009C 70683C 70682C 70817C 100322740560 75630C Poly Tubing Glass Filler Nipple Connector 1/4" Tubing Tee 1/4" Tubing Elbow 1/4" Gasket (4) Glass Filler NOTE: Replacement plumbing hardware components may be ordered as a kit: 1000002033 Glass Filler Hardware and Waterway. Operation of Quick Connect Water Fittings: OPERTION OF QUICK CONNECT FITTINGS Cooler is provided with lead-free connectors which utilize an O -ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the darker gray collar before pulling on the tubing. To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4 (19mm). Deburr cut tube ends before inserting into the Quick Connect Fitting. urrs on the tube end will cut the internal O -Ring and will allow the fitting to leak. SIMPLY PUSH IN TUE TO TTCH TUE IS SECURED IN POSITION PUSH IN COLLET TO RELESE TUE PUSHING TUE IN EFORE PULLING IT OUT HELPS TO RELESE TUE Page 1 97631C (REV. D - 06/17)

HC Model Overview The following illustration shows the tube routing before and after the installation of the Glass Filler Kit. efore (Non-Pressurized Tank) fter (Pressurized Tank) The water storage tank must be converted to a pressurized tank for the glass filler to operate properly. The tank is non-pressurized in a standard unit. The following steps detail how the water flow tubing is re-routed to create a pressurized tank and provide a supply line to the glass filler. Note: Item numbers in the following steps refer to items in Parts List on page 1. STEP 1 Remove Cooler asin Remove lower front panel. Disconnect cooler from electrical supply. Turn off water supply to unit. Remove basin screws () (4 each side, 8 total). If cooler is installed remove strainer and drain plug () or disconnect unit from trap. Lift up basin, remove tubing from bubbler nut (C). Remove upper front panel (D) to hold bubbler fitting from turning. Remove cooler basin. 2.38" 7.00 C STEP 2 Drill or punch an 11/16 (.687 ) diameter hole in the cooler basin per dimensions shown D Step 1 & 2 97631C (REV. D - 06/17) Page 2

C D Step 3() Step 3() STEP 3 Cut and Remove Internal Plumbing Remove tank to bubbler tube (). Disconnect bubbler tube at chilled tank water outlet. Save the tube and bubbler fitting. These will be used in step 4. Cut supply tubes at locations () and (C). Remove and discard bent tubes from water regulator (D). Refer to details Operation of Quick Connect Fittings for removing tubes. STEP 4 Reconnect Internal Plumbing Item 2 Connect water inlet line to chiller inlet. Using (Item 3) reconnect tubes cut at () and (C) Item 4 in step 3. Connect chiller outlet to tee. Item 3 Cut a 12 inch long piece of (Item 1). Install into the chiller water outlet. Connect end to tee (Item 4). Connect tee to regulator and glass filler supply tube. Cut a 6 inch long piece of (Item 1). Connect one end of tube to tee (Item 4) and other end to water regulator inlet (). Cut a 12 inch long piece of (Item 1). Step 4 Connect to tee (Item 4) and to Glass Filler Nipple (Item 2) ubbler Tube Connect bubbler tube to regulator. Use tank to bubbler tube, removed in Step 3, cut length of tube to 10 inches and connect to regulator outlet. STEP 5 Reassemble Unit Connect ubbler and Glass Filler. Using one gasket below the basin and one gasket above the basin assemble the bubbler and glass filler (Item 6) to the basin. Reassemble the unit and leak check. ssemble basin to the unit. Reattach with screws removed in Step 1. Reassemble drain components. Turn on water supply. Run water through bubbler and glass filler. Check all connections for water leaks. Reconnect electrical supply. Replace panels. Step 5 Page 3 97631C (REV. D - 06/17)

SCWT Model Overview The following illustration shows the tube routing before and after the installation of the Glass Filler Kit. efore (Non-Pressurized Tank) fter (Pressurized Tank) The water storage tank must be converted to a pressurized tank for the glass filler to operate properly. The tank is non-pressurized in a standard unit. The following steps detail how the water flow tubing is re-routed to create a pressurized tank and provide a supply line to the glass filler. Note: Item numbers in the following steps refer to items in Parts List on page 1. STEP 1 Remove Cooler Front Panel Remove front panel. Remove screws on kick plate and front panel (). Remove front panel. Disconnect cooler from electrical supply. Turn off water supply to unit. Remove bubbler (). Remove pushbutton (C). If cooler is installed, remove strainer and drain plug (D) or disconnect unit from trap. Remove 4 screws and take off basin. STEP 2 Drill or punch an 11/16 (.687 ) diameter hole in the center of the raised circular pad at the right rear corner of the basin. D C Step 1 & 2 97631C (REV. D - 06/17) Page 4

D C Step 3() Step 3() STEP 3 Cut and Remove Internal Plumbing Remove tank to bubbler tube (). Disconnect bubbler tube at chilled tank water outlet. Cut supply tubes at locations () and (C). Remove and discard bent tubes from water regulator (D). Refer to details Operation of Quick Connect Fittings for removing tubes. STEP 4 Reconnect Internal Plumbing Connect water inlet line to chiller inlet. Using (Item 3) reconnect tubes cut at () and (C) in step 3. Connect chiller outlet to tee. Cut a 8 inch long piece of (Item 1). Install into the chiller water outlet. Connect end to tee (Item 4). Connect tee to regulator and glass filler supply tube. Cut a 6 inch long piece of (Item 1). Connect one end of tube to tee (Item 4) and other end to water regulator inlet (). Cut a 12 inch long piece of (Item 1). Connect to tee (Item 4) and to Glass Filler Nipple ubbler Tube Step 4 (Item 2), not shown. Connect bubbler tube to regulator. Item 4 Item 3 Use tank to bubbler tube, removed in Step 3, cut length of tube to 10 inches and connect to regulator outlet. STEP 5 Reassemble Unit Connect ubbler and Glass Filler. Using one gasket below the basin and one gasket above the basin assemble the bubbler and glass filler (Item 6) to the basin. Reassemble the unit and leak check. Turn on water supply. Run water through bubbler and glass filler. Check all connections for water leaks. Reconnect electrical supply. Replace front panel. Step 5 Page 5 97631C (REV. D - 06/17)

SW/WM Model Overview The following illustration shows the tube routing before and after the installation of the Glass Filler Kit. efore (Non-Pressurized Tank) The water storage tank must be converted to a pressurized tank for the glass filler to operate properly. The tank is non-pressurized in a standard unit. The following steps detail how the water flow tubing is re-routed to create a pressurized tank and provide a supply line to the glass filler. Note: Item numbers in the following steps refer to items in Parts List on page 1. fter (Pressurized Tank) STEP 1 Remove Cooler Front Panel Remove front panel. Remove screws on under side of front panel. () Remove front panel. Disconnect cooler from electrical supply. Turn off water supply to unit. Remove bubbler. () Remove pushbutton. (C) If cooler is installed, remove strainer and drain plug (D) or disconnect unit from trap. Remove 4 screws and take off basin. D C STEP 2 Drill or punch an 11/16 (.687 ) diameter hole in the center of the raised circular pad at the right rear corner of the basin. Step 1 & 2 97631C (REV. D - 06/17) Page 6

D C Step 3() Step 3() STEP 3 Cut and Remove Internal Plumbing Remove tank to bubbler tube (). Disconnect bubbler tube at chilled tank water outlet. Cut supply tubes at locations () and (C). Remove and discard bent tubes from water regulator (D). Refer to details Operation of Quick Connect Fittings for removing tubes. STEP 4 Reconnect Internal Plumbing Connect water inlet line to chiller inlet. Using (Item 3) reconnect tubes cut at () and (C) in step 3. Item 4 Connect chiller outlet to tee. Cut a 8 inch long piece of (Item 1). Install into the chiller water outlet. Connect end to tee (Item 4). Connect tee to regulator and glass filler supply tube. Cut a 12 inch long piece of (Item 1). Connect one end of tube to tee (Item 4) and other end to water regulator inlet (). Cut a 12 inch long piece of (Item 1). Step 4 Connect to tee (Item 4) and to Glass Filler Nipple (Item 2), not shown. Item 3 ubbler Tube Connect bubbler tube to regulator Use tank to bubbler tube, removed in Step 3, cut length of tube to 10 inches and connect to regulator outlet. STEP 5 Reassemble Unit Connect ubbler and Glass Filler. Using one gasket below the basin and one gasket above the basin assemble the bubbler and glass filler (Item 6) to the basin. Reassemble the unit and leak check. Turn on water supply. Run water through bubbler and glass filler. Check all connections for water leaks. Reconnect electrical supply. Replace front panel. Step 5 Page 7 97631C (REV. D - 06/17)

S-Series Model Overview This illustration shows the tube routing before and after the installation of the Glass Filler Kit. efore fter The water storage tank must be converted to a pressurized tank for the glass filler to operate properly. The tank is non-pressurized in a standard unit. The following steps detail how the water flow tubing is re-routed to create a pressurized tank and provide a supply line to the glass filler. Note: Item numbers in the following steps refer to items in Parts List on page 1. STEP 1 Remove front panel. Disconnect cooler from electrical supply. Turn off water supply to unit. STEP 2 Drill or punch an 11/16 (.687 ) diameter hole in the location shown at the right rear corner of the basin. If basin needs to be removed, disconnect tube from bubbler, refer to detail on page 1 of operation of quick connect fittings. Remove pushbutton/regulator assy. () by removing chrome cover nut and pushbutton cap then large chrome hex nut. If cooler is installed, remove trap from drain tube. Remove 4 screws () and take off basin. 1.61 Step 1 & 2 1.81 97631C (REV. D - 06/17) Page 8

STEP 3 Cut and Re-Route Internal Plumbing Remove both tubes from regulator. () Remove tank to bubbler tube () at the bubbler. Cut this tube 6 from the free end and insert this 6 piece in the regulator inlet port. Connect this 6 piece of tube to the remaining part of the tube using the tee (Item 4). Connect the branch of the tee to the glass filler nipple (Item 2) Connect water inlet strainer to the copper tube connected to the chiller inlet. This is now the water inlet line. Item 2 Connect bubbler to regulator using a piece of polytube (Item 1). Item 1 Item 4 Step 3 STEP 4 Reassemble Unit Connect Glass Filler. Using one gasket below the basin and one gasket above the basin assemble the bubbler and glass filler (Item 6) to the basin. Reassemble the unit and leak check. Turn on water supply. Run water through bubbler and glass filler. Check all connections for water leaks. Reconnect electrical supply. Replace front panel. Step 4 Page 9 97631C (REV. D - 06/17)

HTVZ Model Overview The following illustration shows the tube routing before and after the installation of the Glass Filler Kit. efore (Non-Pressurized Tank) fter (Pressurized Tank) The water storage tank must be converted to a pressurized tank for the glass filler to operate properly. The tank is non-pressurized in a standard unit. The following steps detail how the water flow tubing is re-routed to create a pressurized tank and provide a supply line to the glass filler. Note: Item numbers in the following steps refer to items in Parts List on page 1. Step 1 Lower Cover Removal F To access the refrigeration system and plumbing connections, remove the four screws (E) to remove lower cover (F). Disconnect unit from electrical supply. Turn off water supply to unit. E Step 1 97631C (REV. D - 06/17) Page 10

STEP 2 Remove Cooler asin Remove basin screws (2 each side, 4 total). If cooler is installed remove strainer and drain plug or disconnect unit from trap. Lift front of basin and disconnect bubbler tube from bubbler. Refer to details "Operation of Quick Connect Fittings" for removing tubes. Remove cooler basin. Remove glass filler plug from basin If the hole HS NOT been prepunched, then drill or punch a 11/16 (.687 ) diameter hole in the cooler basin where shown or desired. Note: Tube length may vary depending upon glass filler location. Cut and Remove Internal Plumbing Disconnect bubbler tube () at chilled tank water outlet.save the tube. This will be used in step 4. Disconnect supply tubes at locations () and (C). Remove and discard bent tubes from water regulator (D). Refer to details Operation of Quick Connect Fittings for removing tubes. 3.75 3.75 SCREWS Step 2 STEP 3 Reconnect Internal Plumbing Connect water inlet line to chiller inlet. Connect chiller outlet to tee (Item 4). Cut a 12 inch long piece of tube (Item 1). Install into the chiller water outlet. Connect end to tee (Item 4). Connect tee to regulator and glass filler supply tube. Cut a 6 inch long piece of tube (Item 1). Connect one end of tube to tee (Item 4) and other end to water regulator inlet (D). Cut another 12 inch long piece of tube (Item 1). Connect tube to tee (Item 4) and to Glass Filler Nipple (Item 2). Connect bubbler tube to regulator. Use tank to bubbler tube, removed in Step 2, cut length of tube to 10 inches and connect to regulator outlet. Step 3 STEP 4 Reassemble Unit Using one gasket (Item 5) below the basin and one gasket (Item 5) above the basin assemble the glass filler (Item 6, not supplied) to the basin with glass filler nipple (Item 2). Connect bubbler tube to glass filler nipple in basin. Flush components and leak check. ssemble basin to the unit. Reattach with screws removed in Step 2. Turn on water supply and reconnect electrical supply. Run water through the bubbler by depressing pushbar and through glass filler. Check all connections for leaks. Reinstall lower panel with screws removed in step 1. Step 4 Page 11 97631C (REV. D - 06/17)

GLSS FILLER CONNECTION RER VIEW 5, 6 2, 5 4 2222 CMDEN COURT OK ROOK, IL 60523 FOR PRTS, CONTCT YOUR LOCL DISTRIUTOR OR CLL 1.800.834.4816 630.574.3500 REPIR SERVICE INFORMTION TOLL FREE NUMER 1.800.260.6640 97631C (REV. D - 06/17) Page 12