USER MANUAL. Uninterruptible power supply MODEL: 53965,

Similar documents
BRAVER UPS. (Uninterruptible Power System) User s Manual

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

USER MANUAL. Line Interactive UPS. Uninterruptible Power System

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

MM-AVR UPS Series User s Manual

CP900EPFCLCD User s Manual K

Eclipse Plus VA UPS and Surge Suppressor User s Manual

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Uninterruptible Power Supply

Line Interactive UPS 1000/1400/2000VA Uninterruptible Power System

USER MANUAL MPS 1-5KW SERIES

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

PR1000ELCD / PR1500ELCD User s Manual

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Uninterruptible Power System

Limousin II User Manual

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

UTILITY INPUT MAINS OUTLET

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Powerware Vdc Extended Battery Cabinet User s Guide.

Power Protection System With AVR UPS. Model: 350VA~1600VA LINE INTERACTIVE UPS USER'S MANUAL

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

400 Watt Backup Power System Owner s Manual

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

Installation and Operation Manual Back-UPS BR800/1100CI-IN

1. INTRODUCTION. Features:

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Uninterruptible Power System

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

General Precautions. Personnel Precautions

Installation and Operation Back-UPS BX550CI-CN

Pulsar EXtreme CLA 1500C

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

Informer Compact Series

Installation and Operation Manual Back-UPS BX1100CI-CN

Uninterruptible Power System

PI1500X Power Inverter User s Manual

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Uninterruptible Power System

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

POWERWARE User s Guide VA.

Pulsar Evolution 2200/3000/3000 XL

Universal 8-Bay Charger. for AA/AAA/C/D/9 NiMH & NiCd Rechargeable Batteries. Owner's Manual

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

User Manual Rittal PMC UPS 6kVA

User s Manual Legend SB825 UPS K

8-Bay Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual. Please read before using this equipment.

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Uninterruptible Power Supply USER MANUAL Version 1.4. Always On UPS Systems Inc. GES-801L, GES-102L, GES-152L, GES-202L, GES-302L

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

MP V 8A Electronic Smart Charger. Instruction and Information Manual

SLSPGN10. Portable Power Generator. Rechargeable Battery Pack Power Supply Solar Panel Compatible (40,800mAh Capacity)

Back-UPS CS Back-UPS CS 350

MULTI-FUNCTION JUMP STARTER

OWNER S MANUAL POWER INVERTER

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

U P S. Uninterruptible Power System Unterbrechungsfreie Stromversorgung

innovations in battery charging

User s Manual. Automatic Switch-Mode Battery Charger

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

Inverter User Manual

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

User Manual V1.0 MaxiFlex 3000

Installation and Operation Manual Back-UPS BR1000-CH

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

M Series External Battery Frame. User Guide

02/15/01. Powerware User s Guide VA.

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

1000-Watt Energy Center

Instruction Manual BX75XS2. Uninterruptible Power Supply (UPS)

TABLE OF CONTENTS. 300 W Mobile Power Outlet SAVE THESE INSTRUCTIONS!

OPERATIONAL MANUAL .TYPE - ONLINE UNINTTERRUPTIBLE POWER SUPPLY

1. Important Safety Warning

Transcription:

USER MANUAL Uninterruptible power supply MODEL: 53965, 53966 www.qoltec.com

Please check if the package contains: - UPS unit - Power cable (1 x SCHUKO) 1.2 m - User manual This UPS provides comprehensive protection in a small and economic package. The UPS is more compact and offers greater comprehensive power protection against surges and spikes. This UPS will continue providing stable power to connected equipment and enable to shutdown PC safely during power failure. It has embedded microprocessor controller which guarantees high reliability and it s perfect for any home or small office application. Front view: AC normal inductor (green) Back-up inductor (red) Battery charging inductor (yellow) Power switch 3 x SCHUKO Backup and Surge Protection 3x SCHUKO Surge Protection 2 x USB (5V, 2A) Note: Before installation, please check the unit. Make sure that nothing inside the package is damaged. Install the UPS in a protected area that is free of excessive dust and has adequate air flow. Please place the UPS away from other units at least 20 cm to avoid interference. DO NOT operate the UPS where the temperature and humidity are outside the specified limits. (Please check the specification).

Plug in the AC input cord to the wall outlet. For the best results, suggest charging the battery at least 8 hours before initial use. The unit charges its battery while connecting to the utility. Plug in the loads to the output receptacles on the rear panel of the UPS. Simply turn on the power switch of UPS unit, then devices connected to the UPS will be protected by UPS. CAUTION: Only bypass output can connect a laser printer or scanner. Otherwise, it may cause the damage of the unit. 2 independent USB ports (5V, 2A) are used for convenient charging without the help of external devices. Turn on the UPS by pressing the power switch. Turn off the UPS by pressing again the power switch. When the UPS is off and there is no power utility, it s still possible to use cold start the UPS unit to power the loads. When AC fails, and the battery supplies power to the device, UPS will alarm once every 6 seconds and the beep stops about 40 seconds later. When the battery is nearly used up, the UPS will alarm automatically and the beep frequency is once 2 seconds. When the battery is really used up, the UPS will alarm for a very long time and turn off automatically. When UPS is in the battery mode and there is no shock or short-circuit, UPS will emit a limited amount of current to protect itself. (In mains mode, the UPS will be protected by input fuse firstly and then transfer to the battery mode.)

To prevent the risk of fire or electric shock, install UPS in a controlled temperature and humidity indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and humidity range.) To reduce the risk of overheating the UPS, do not cover the UPS cooling vents and avoid to exposing the unit to direct sunlight or installing nearby devices which emit the heat. Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwaves or vacuum cleaners to the UPS. Do not plug the UPS input into its own input. Do not allow liquids or any foreign objects get to the inside of the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit. In the case of emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS. Do not plug a power strip or surge suppressor to the UPS. If the UPS has a metal casing, for safety purpose, grounding is necessary during UPS installation in order to reduce leakage current below 3.5mA. The risk of electric shock. Also with disconnection of this unit from the mains, dangerous voltage still may be accessible through supply from the battery. The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS. Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. When you replacing the batteries, use the same number and type of batteries. Internal battery voltage is 12V DC. Sealed, lead-acid, 6-cell battery. Do not dispose of batteries in a fire. The battery may explode. Do not open the battery. Released electrolyte is harmful to the skin and eyes. Unplug the UPS prior to cleaning and do not use liquid or spray detergent. A battery can make a risk of electric shock and high short circuit current. The following precaution should be done before replacing batteries: 1) Remove watches, rings or other metal objects. 2) Use tools with insulated handles. 3) Wear rubber gloves and boots.

4) Do not lay tools or metal parts on top of batteries. 5) Disconnect charging source prior to connecting or disconnecting batteries terminal. Preventative maintenance ensures the longer service life of UPS. Please check the following things every month: 1. Make sure the air flow is not blocked; 2. Make sure that the UPS surface is not covered by dust; 3. Check that the connection cables, the output and the connecting cables are properly connected and that the insulation is effective; 4. Make sure that the UPS is not affected by moisture; 5. Let the UPS work in battery mode for about 5 minutes and in this period, if there is no other alarm from the UPS, then the UPS works normally; if there is other alarm message, please contact your seller for help. The UPS contains sealed lead-acid maintenance-free battery. The bad environment, high discharging frequency, high temperature, will dramatically reduce the service life of battery. The service life of battery will also reduce even it is not used. It is suggested to discharge the battery once every 3 months when AC is normal. Short works of the battery mean that you need to change it for a new one. Use this table below to solve your problems. Problem Probable cause Solution The fuse is placed with AC input of the The mains is normal, but the UPS is AC input fuse is broken UPS. After disconnecting the AC plug, put working in the battery mode out the fuse and replace it with a new one. Please turn on the UPS and charge the When AC fails, the computer doesn t Battery low voltage battery for at least 10 hours, when AC is work. normal and then turn on the UPS. The UPS is overload Remove some critical loads. Battery voltage is too low Charge UPS at least 8 hours. When power fails, backup time is Battery defect. It might due to high shorten. temperature operation environment or improper Replace the battery with the same type. operation to battery.

CAPACITY 500VA 600VA/650VA 700VA/750VA 800VA/850VA INPUT Voltage 100V/110V/120V or 220V/230V/240V Voltage range ±25% OUTPUT Power factor 0.6 Voltage regulation ±10% Transfer time 10ms Wave form Simulated sine wave BATTERY Type and number 1x12V/7Ah 1x12V/8Ah Charging time 8 hours recover to 90% capacity PHYSICAL Dimension (W x D x H) 280 x 185 x 95 mm Net weight 4.5 kg 4.8 kg 5.6 kg ENVIRONMENT Humidity 20% ~ 90% (relative humidity), 0-40 o C (non-condensing) Noise level 45dB (1m) USB/RS-232 (Option) Supports Windows 98/2000/2003/XP/Vista/2008/Windows 7/Windows 8/ Windows 10 Producer: ntec Ul. Chorzowska 44B 44-100 Gliwice Poland www.qoltec.com