PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA

Similar documents
SECULIFE PS100 PATIENT SIMULATOR

CP GermanCp 41_CP C. Operating Instructions. CP 30 CP 330 CP 1100 AC/DC current probe /7.10

KSZ 10B Current Probe Calibrator. Instruction Manual

Operatingmanual. Mehrsprachige Anleitung unter Multilingual manuals at. pro BENNING TRITEST BENNING BENNING BENNING.

Charging cables mode 3 case B

original operating manual Operating manual Manual flow meter FMOGne Translation of the Item-No.: ,

KSZ 100B Current Probe Calibrator. Instruction Manual

362 Clamp Meter. Users Manual

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Exchange of rollers from the XTS-Mover

Operating instructions

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Operating instruction and technical description

KeContact P20. User manual

AXIAL FANS Axis / Tubo OPERATION MANUAL

Meter FMT II. Operating manual. original operating manual. Translation of the

Technical Documentation

original operating manual Operating manual Translation of the Item-No.: ,

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Off-line filter system

Rental Industry Safety Tester Safe Check 5s

Rexroth IndraDyn E. Standard Motors MOT-FC for Frequency Converter Operation. Project planning manual R Edition 03

M A N U A L. Field Current Controller F2.2

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

Operating Instructions

BODAS Pressure sensor PR3 series 10

EGQ 212: Duct transducer, CO 2 and temperature

Tester for Motor-Driven Relays Type Siemens SICO 1225 M A N U A L

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

Level Measuring Sensor for Diesel Fuel Tanks

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Pressure relief valve

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Wilo-Control SC-Fire Jockey

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Important instructions

Instruction Manual. Sewage lifting station compli 300

Ex m Solenoid Operator Type 0519

Instruction manual. CSV 402 caravan power supply. Table of contents

INSTRUCTION & INSTALLATION

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Register your instrument! HeatSealer S100. Operating manual

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

WPS02 Waste powder conveying with BIG-BAG station

MANUAL. Single charger

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

DeltaSol AX * *

FMM-P-L. FluidMonitoring Module. Installation and Maintenance Instructions. English (translation of original instructions) Document No.

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Appendix: Safety and application notes for... 15

L Charger. Instruction manual

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Application cup for OptiFlex 2 GM03 manual powder gun

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

HST-BL-2830MS & HST-BL-2830MS-USA

1.Safe testing IMPORTANT:

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

MINI MCR-SL-UI-UI(-SP)(-NC)

Certificate of Conformity self-generation unit

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

Angle Sensor WS1. RE Edition: Replaces:

Operating instructions and spare parts list. Waste powder conveying from recovery container WPS01

Tension Meter. PT Series. Instruction Manual PT-100-L. Valid as of: Please keep the manual for future reference!

Operating Instructions for Roll-Up Door Operators / MDF

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Manual Electronic Identification Systems BIS Read/Write Heads C3-slk_716464_E_1110.p65 Deutsch bitte wenden!

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

Katalysator Nr /

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

Operating Instructions

323/324/325 Clamp Meter

362 Clamp Meter. Users Manual

Installation manual wall-mounted distributor

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Assembly and Maintenance Manual Type RSBW

Oil-free piston compressors KK and piston vacuum pumps KV

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

OPERATING INSTRUCTIONS

Mod: KLD6-12/35XLAS-N

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

Power Panel 6 W Potentiometer

Swing Piston Compressors and Vacuum Pumps

Installation and Operating Instructions Magnetic Vibrator MR 1

Appendix: Safety and application notes for 19

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

i3000s/i2000 Flex AC Current Probe

Transcription:

PRO-TYP II Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA 3-349-884-03 1/10.15

Opening of Equipment / Repair The equipment may be opened only by authorized service personnel to ensure the safe and correct operation of the equipment and to keep the warranty valid. Even original spare parts may be installed only by authorized service personnel. In case the equipment was opened by unauthorized personnel, no warranty regarding personal safety, measurement accuracy, conformity with applicable safety measures or any consequential damage is granted by the manufacturer. Device Return and Environmentally Compatible Disposal The instrument is a category 9 product (monitoring and control instrument) in accordance with ElektroG (German Electrical and Electronic Device Law). This device is subject to the RoHS directive. Furthermore, we make reference to the fact that the current status in this regard can be accessed on the Internet at www.gossenmetrawatt.com by entering the search term WEEE. We identify our electrical and electronic devices in accordance with WEEE 2012/19/EU and ElektroG with the symbol shown to the right per DIN EN 50419. These devices may not be disposed of with the trash. Please contact our service department regarding the return of old devices. If you use batteries or rechargeable batteries in your instrument or accessories which no longer function properly, they must be duly disposed of in compliance with the applicable national regulations. Batteries or rechargeable batteries may contain harmful substances or heavy metal such as lead (PB), cadmium (CD) or mercury (Hg). They symbol shown to the right indicates that batteries or rechargeable batteries may not be disposed of with the trash, but must be delivered to collection points specially provided for this purpose. Pb Cd Hg

Table of Contents General Notes... 1 Basic Safety Precautions... 2 Product Overview... 3 Initial Start-Up... 4 VDE Testing at Charging Stations with the Help of the... 4 Maintenance... 5 Technical Data... 5 Appendix: Practical Information on Testing Charging Stations... 6 General Notes Read the operating instructions thoroughly and carefully before using your instrument. Follow all instructions contained therein. Make sure that the operating instructions are available to all users of the instrument. Explanation of Symbols This product fulfills guidelines in accordance with 89/336/EEC. Warning regarding property damage. Safety precautions must be adhered to. Warning regarding personal injury. Safety precautions must be adhered to. Page 1

Basic Safety Precautions Guarantee No guarantee is made with regard to function and safety unless the warnings and safety precautions included in these operating instructions are observed. GMC-I Messtechnik GmbH assumes no liability for personal injury or property damage which occurs due to non-observance of the warnings and safety precautions. Use for Intended Purpose The PRO-Typ II test adapter is intended exclusively for performing tests in accordance with DIN VDE 0100-600/DIN VDE 0105-100 for the effectiveness of protective measures at charging stations for electric vehicles with type 2 connector socket (mode 3 charging). The PRO-TYP II test adapter establishes a connection between the charging station and a PROFITEST MASTER to this end. Use for other purposes is prohibited. In particular, the test sockets and the earthing contact socket may not be used in order to connect electric loads to the charging station. Testing Conducted by a Qualified Electrician in Accordance with German Occupational Safety Law and TRBS1203 Only trained, qualified electricians may use the PRO-TYP II test adapter. Trained, qualified electricians fulfill the following requirements: Knowledge of general and specific accident prevention regulations Knowledge of applicable electrotechnical regulations Training in use and care of appropriate safety equipment Ability to recognize hazards associated with electricity Warning! Danger! The PRO-Typ II test adapter may only be used to conduct tests at charging stations for electric vehicles with type 2 connector socket (mode 3 charging) in accordance with DIN VDE 0100-600/DIN VDE 0105-100. The device may only be used in combination with the PROFITEST MASTER (DIN VDE 0413)! The adapter is not intended for operation of electric loads at the test sockets or the earthing contact socket, which may result in severe property damage and personal injury! Page 2

Product Overview Scope of Delivery PRO-TYP II test adapter Operating instructions Device Layout Key 1 Rotary switch, vehicle state (CP) 2 Rotary switch, cable (PP) 3 Test sockets (PE, N, L1, L2, L3) 4 Earthing contact socket (PE, N, L1) 5 Phase sequence indicator LEDs 6 Type II plug for charging stations Page 3

Initial Start-Up General Warning! Danger! The PRO-TYP II test adapter should be checked to assure that it s in good condition before initial start-up. The device may not be used if it s damaged. The device may only be used by trained personnel. Connecting a PROFITEST MASTER The PRO TYP II test adapter is equipped with an earthing contact socket (4), as well as test sockets to which a PROFITEST MASTER can be connected. Maximum permissible load for the connections may not be exceeded when testing a charging station (230 V, max. 13 A). Observe the manufacturer s instructions when connecting the PROFITEST MASTER. Connecting the to a Charging Station The device is equipped with a type 2 plug (6) for connection to the charging station. This can be plugged into the charging station. If applicable, authorization at the charging station is required to this end. VDE Testing at Charging Stations with the Help of the VDE tests can be conducted at charging stations in accordance with IEC 61851 with the help of the PRO-Typ II test adapter in combination with a PROFITEST MASTER. The test adapter triggers the charging process by simulating an electric vehicle. Only by means of simulation is the charging station s outlet energized so that it can be tested with the PROFITEST MASTER. The test adapter makes the following functions available: Vehicle Simulation (CP) States A, B, C, D and E can be simulated in accordance with IEC 61851. The various vehicle states are selected by means of a rotary switch (1). State A: No vehicle connected State B: Vehicle connected, but not ready for charging State C: Vehicle connected and ready for charging without venting State D: Vehicle connected and ready for charging with venting State E: Error short circuit between CP and PE via internal diode Page 4

Cable Simulation (PP) The various codings for charging cables with 13, 20, 32 and 63 A can be simulated. It s also possible to simulate the no cable state. The various charging cables are simulated by connecting different resistances between PP and PE with the help of a rotary switch (2). The following values are possible in accordance with IEC 61851: No cable: 0 Ω 13 A cable: 1.5 kω 20 A cable: 680 Ω 32 A cable: 220 Ω 63 A cable: 100 Ω Fault Simulation The test adapter s rotary switch (1) can be turned to E in order to simulate a short-circuit between CP and PE via an internal diode. A pending charging process must be aborted as a result, and a new charging process must be prevented. Phase Sequence Indicator The PRO-TYP II test adapter is equipped with LEDs (5) which indicate phase sequence. As soon as the phase conductors are energized, the LEDs light up red. Depending on the layout of the charging station, either one or three phases can be active. An active charging process and at least one voltage conducting phase are prerequisites for VDE testing. Maintenance Due to the device s characteristics, no maintenance should be carried out by the user. If repairs should become necessary, please contact us. Outside surfaces may only be cleaned with a dry, lint-free cloth. Danger! No liquids may be permitted to penetrate into the device s interior or the plug connectors. Technical Data Input voltage: Frequency: Test consumer power: Protection: IP 20 Operating temperature: -10 to 45 C 400 V (3-phase) 50 Hz Max. 2.9 kva (no continuous operation!) Storage temperature: -25 to 60 C Relative humidity: Up to 80% (no condensation) Page 5

Appendix: Practical Information on Testing Charging Stations Type II Plug for Mode 3 Charging Source: Mennekes Resistance Coding for Charging Cables (PP) Source: DKE Deutsche Kommission Elektrotechnik Elektronik Informationstechnik im DIN und VDE Page 6

Typical Pilot Circuit for Mode 3 Charging Source: DKE Deutsche Kommission Elektrotechnik Elektronik Informationstechnik im DIN und VDE Page 7

Typical Pilot Circuit for Mode 3 Charging Source: DKE Deutsche Kommission Elektrotechnik Elektronik Informationstechnik im DIN und VDE Page 8

System States PWM Voltage Source: DKE Deutsche Kommission Elektrotechnik Elektronik Informationstechnik im DIN und VDE Page 9

System States PWM Voltage System States PWM Voltage Source: DKE Deutsche Kommission Elektrotechnik Elektronik Informationstechnik im DIN und VDE State A State B State C State D State X State A: State B: State C: State D: State X: No vehicle connected Vehicle connected, but not ready for charging Vehicle connected and ready for charging without venting Vehicle connected and ready for charging with venting Error Page 10

System States Duty Cycle Source: DKE Deutsche Kommission Elektrotechnik Elektronik Informationstechnik im DIN und VDE Page 11

System States Duty Cycle Page 12

Repair and Replacement Parts Service Calibration Center * and Rental Instrument Service Bitte wenden Sie sich im Bedarfsfall an: When you need service, please contact: GMC-I Service GmbH Service Center Thomas-Mann-Strasse 20 90471 Nürnberg Germany Phone +49 911 817718-0 Fax +49 911 817718-253 E-Mail service@gossenmetrawatt.com www.gmci-service.com This address is only valid in Germany. Please contact our representatives or subsidiaries for service in other countries. * DAkkS Calibration Laboratory for Electrical Quantities D-K-15080-01-01 accredited per DIN EN ISO/IEC 17025:2005 Accredited measured quantities: direct voltage, direct current values, DC resistance, alternating voltage, alternating current values, AC active power, AC apparent power, DC power, capacitance, frequency and temperature 1 Product Support When you need support, please contact: GMC-I Messtechnik GmbH Product Support Hotline Phone +49 911 8602-0 Fax +49 911 8602-709 E-Mail support@gossenmetrawatt.com Edited in Germany Subject to change without notice A pdf version is available on the Internet GMC-I Messtechnik GmbH Südwestpark 15 90449 Nürnberg Germany Phone +49 911 8602-111 Fax +49 911 8602-777 E-Mail info@gossenmetrawatt.com www.gossenmetrawatt.com