PROCUREMENT SPECIFICATION DELTA MODEL DSC900 TRANSPORTABLE CRASH CERTIFIED RISING PLATE BARRIER SYSTEM

Similar documents
PROCUREMENT SPECIFICATIONS DELTA MODEL DSC 1500 PORTABLE BEAM - CRASH CERTIFIED BARRIER SYSTEM

PROCUREMENT SPECIFICATION MODEL TT210 BOLLARD HYDRAULIC BARRICADE SYSTEM

PROCUREMENT SPECIFICATION MODEL TT207S/FM PHALANX* SURFACE MOUNT HYDRAULIC BARRICADE SYSTEM

PROCUREMENT SPECIFICATION MODEL TT207S PHALANX* TYPE HYDRAULIC BARRICADE SYSTEM

PROCUREMENT SPECIFICATION MODEL DSC800 HYDRAULIC BOLLARD BARRICADE SYSTEM

MODEL DSC501 PHALANX TYPE BARRICADE SYSTEM HYDRAULICALLY OPERATED CRASH TESTED AND CERTIFIED MINIMUM DEPTH FOUNDATION CONFIGURATION

MODEL DSC501- K54 PHALANX TYPE BARRICADE SYSTEM

MODEL DSC2000 SYSTEM

TYPE BARRICADE SYSTEM PROGRAMMABLE ELECTRO-MECHANICAL DRIVE SYSTEM CRASH TESTED AND CERTIFIED VERY HIGH SECURITY FULLY ENCLOSED BARRICADE,

PROCUREMENT SPECIFICATION MODEL DSC720M 1M MANUAL BOLLARD BARRICADE SYSTEM

PROCUREMENT SPECIFICATION MODEL SC3000S CRASH RATED CANTILEVER GATE SYSTEM WITH TT260 ELECTRO-MECHANICAL RACK AND PINION OPERATOR

SYNOPSIS. This specification defines a CRASH TESTED - CRASH CERTIFIED - HIGH SECURITY BOLLARD BARRICADE SYSTEM DELTA Model DSC720 1M Hydraulic.

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

SECTION HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS

Parking Control Equipment Vehicle Fare Collection Roadway Construction Roadway Equipment

Door Interlock System - For Invasion Stoppage

Electro Pneumatic Workbench Scientech 2470

Three-Phase Pole Mounted Recloser

SECTION MOTOR CONTROL

REVISIONS. App Thom. App Sud. App PC T.C. 2013/10/01

BID PROPOSAL. Item Description Unit Quantity Unit Price Total Price No. (Unit Price to be written in Words) (Figures) (Figures)

MPD Manifold 4-1/ psi with Integrated Control System

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Electropneumatic Timing Relays Series 7000 Industrial

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

Internal Roller Swage Tooling & Equipment

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

TCM D Single Zone, 24 Volt DC Timer Control Module User s Manual D-M-E Company

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

RB72-3 HD Flush Mounted Directional Traffic Spikes Installation and Operating Precautions

Electro Pneumatic WorkStation Scientech 2470

Datasheet. Electrical Switching / Locking

SENTINEL SHALLOW MOUNT ANTI-RAM WEDGE PRODUCT DETAIL SPECIFICATION AMERISTARSECURITY.COM

MCD Pump Application Module

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

TRAFFIC AND PARKING SYSTEMS SPIKES, BARRIER GATES AND COMPONENTS

Self-Repairable High Speed Doors Standard Interior - 100SR Low-Temp - 104SF Interior Reinforced - 110RI Exterior Reinforced - 140RA

DEFENDERTM ANTI-RAM BOLLARDS PRODUCT DETAIL SPECIFICATION AMERISTARSECURITY.COM

MODEL 422 Submersible Pump Controller

MODEL 850 SERIES TOWABLE VEHICLE BARRIER

Underground Distribution Switchgear

StrongArmCRASH M30 ( K4) M50 ( K12) Patent Pending. Patent Pending

EIM CONTROLS HQ-SERIES QUARTER TURN ELECTRIC ACTUATORS

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Indianapolis Power & Light Company

Actuator Arm and Control Box Mounting

SECTION ELECTRIC MOTOR ACTUATORS FOR VALVES

(electronic Access & Security Keyless-entry)

Transfer switch OTEC and OTECSE open transition


SE2000BX Static Exciter

Declaration of Conformity

Owner s Manual. Model 9300 Vehicular Slide Gate Operator

TRAFFIC ENGINEERING DIVISION INSTRUCTIONAL & INFORMATIONAL MEMORANDUM

D. Operation and Maintenance Data. In addition to items specified in Division 1 Section "Operation and Maintenance Data," include the following:

OTEC Transfer switch open transition

AZM300 More than just a solenoid interlock

Propeller Hooded Roof Fans

Operating Instructions Type MPT 53

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm)

Power Conversion. Battery Chargers. Model

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

IDEM Solenoid Interlock Safety Switches

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

(1032 mm) 30.5 (775 mm) 44 ( mm)

MST FULL HEIGHT TURNSTILES TYPICAL INSTALLATION SITES COMMON APPLICATIONS DESCRIPTIVE SPECIFICATIONS ALVARADOMFG.COM

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

SECURITY DOOR CONTROLS

Installation Instructions

USERS GUIDE LO-21U LOCKOUT RELAY

SIGNAL WORDS QUALIFIED PERSON

F01 Electric Actuators

MPD Manifold 4-1/ psi with Integrated Control System

Single-phase step voltage regulators

StopGate TM Barrier Arm GENERAL SPECIFICATIONS

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Transfer switch OTEC open or delayed transition

Prevents Unscheduled Truck Departures

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

MST. Full Height Turnstiles. alvaradomfg.com

VEHICLE AND PEDESTRIAN CONTROL

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Prism PI Intelligent features offer advanced performance

2017 CATALOG East Main Street Mesa, AZ

Installation and Operating Manual

University of Houston Master Construction Specifications Insert Project Name

L kw Distributed Energy Storage System Unit (SU50)

STATEMENT OF WORK. Sinnemahoning State Park Cameron County, Pennsylvania

Installation/Owner s Manual 1601 / 1602

University of Houston Master Construction Specifications Insert Project Name

Installation/Owner s Manual 1601 / 1602

APOLLO Gate Operators, Inc.

A6Z OPERATING MANUAL

TS , -850 Series TS , -850 Series TS-57031, TS

Gas Insulated Metal-clad Switchgear, HMGS!

BREAK-SAFE Load Break & Pick-up Tool

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Owner s Manual. Model 9310 Vehicular Slide Gate Operator

Transcription:

PROCUREMENT SPECIFICATION DELTA MODEL DSC900 TRANSPORTABLE CRASH CERTIFIED RISING PLATE BARRIER SYSTEM SYNOPSIS This Procurement Specification defines a CRASH CERTIFIED - TRANSPORTABLE BARRIER SYSTEM - DELTA Model DSC 900. The system is modular in construction and configured for expedited deployment and, as needed, retrieval and relocation. This Barrier System can be sited on existing concrete or asphalt roadways or verges, level compacted soils or some combination of these. No excavation or sub-surface preparation is required. A Phalanx*** Type Rising Plate Barrier is mounted in multiple Inertial Pods located on either side of the roadway to be protected. The Pods consist of a permanent steel housing back-filled with local materials (concrete, sand, gravel or other dense material) either in situ or remotely. After positioning they are interlocked with quick lock- unlock pins. Each Pod has fork-lift slots for moving and positioning. The Plate Barrier is raised and lowered into position utilizing a hydraulic cylinder driven by a DELTA Hydraulic Power Unit or manually operated, with the weight of the Plate Barrier being balanced by a Hydraulic-pneumatic balance system (U.S. Patent # 5,560,733 dated 10/1/96).* The Hydraulic Pumping Unit can be sized to provide pass-through rates suitable for most inspection and identification station requirements. Operating modes include, full automatic, remote- hard line, remote-radio, card reader, key switch or by local guard push button station...etc. - or by combinations thereof. 1.0 PATENT LICENSE. SPECIFICATION The TRANSPORTABLE CRASH CERTIFIED RISING PLATE BEAM BARRIER SYSTEM shall be fully licensed for manufacture under U.S. Patent Number 4,844,653 dated July 4, 1989, U. S. Patent # 5,560,733 and others pending. Copyright 2001 Delta Scientific Corporation Page 1 of 5

2.0 SYSTEM CONFIGURATION 2.1 Barrier Construction. Barrier shall be an above grade, transportable assembly containing a Rising Plate Barrier, raised and lowered by means of a Hydraulic Power Unit. When in the raised position the Plate Barrier shall present a formidable obstacle to approaching vehicles. Upon vehicle impact, the force shall first be absorbed by the beam assembly and then transmitted to the Initial Pods. 2.2 Barrier Height. Height of the Barrier shall nominally be 22 inches (0,56 M) with the Blade Barrier in the full up (guard) position. 2.3 Barrier Clear Opening. The standard clear opening shall be 144 inches (3,66 M) as measured inside to inside of the Inertial Pods. (Barrier can be specified with a clear opening from 120 inches [3,05 M] to 180 inches [4,57 M]).* 2.4 Finish. All external surfaces of the Inertial Pods and the Rising Plate Barrier shall have rust inhibiting painted surface. The insides of the Inertial Pods shall be asphalt emulsion coated for corrosion protection. The Rising Plate shall be furnished with alternate yellow / white stripes on both upper and lower surfaces. 2.5 Configuration Drawing. Delta Drawing 8488 3.0 OPERATION 3.1 Hydraulic Operation. The Standard Barrier shall be capable of being raised or lowered in 3 seconds. 3.1.2 A field adjustable speed control element within the Hydraulic Circuit shall be provided to increase the operating time to fit local operating needs. 3.1.3 Barrier direction shall be instantly reversible at any point in its cycle from the control station(s). 4.0 PERFORMANCE 4.1 Experience. Barrier and auxiliary equipment shall be of a proven design. Manufacturer shall have 10 years documented experience with similar vehicle Barriers. 4.2 Certifications. Barrier shall have a Certified rating of K4 / L2 Copyright 2001 Delta Scientific Corporation Page 2 of 5

5.0 HYDRAULIC POWER UNIT 5.1 Hydraulic Circuit. Unit shall consist of an electrically driven hydraulic pump which shall be connected to electrically actuated valves installed on a manifold to allow oil to be driven to raise or lower the Barrier. The hydraulic circuit shall include all necessary control logic, interconnect lines and valves. 5.2 Main Power. The electric motor driving the hydraulic pump shall be fed from (site voltage, phase and frequency, i.e. 230/3/60).** Motor shall be sufficiently sized for the expected number of Barrier operations. 5.2.1 Frequency of Operation. Barrier shall be capable of 120 complete up/down cycles per hour. 6.0 CONTROL AND LOGIC CIRCUITS - The following control circuits and stations shall be furnished: 6.1. Control Circuit. A control circuit shall be provided to interface between all Barrier control stations and the hydraulic power unit. This circuit shall contain all PLCs, relays, timers and other devices necessary for the Barrier operation. 6.1.1 Voltage. The control circuit shall operate from a (120 volt, 50/60 Hz supply 240 volt, 50/60 Hz or 24 VDC **). An internally mounted transformer shall reduce this to 24 VAC (24 VDC) for all external control stations. 6.1.2 Power Consumption. The control circuit power consumption shall not exceed 250 watts basic load, plus 200 watts for each Barrier in the system. 6.1.3 Construction. The control circuit shall be mounted in a general purpose enclosure. All device interconnect lines shall be run to terminal strips. 6.2 Standard Remote Control Station. A standard remote control station shall be supplied to control the Barrier operation. This panel shall have a key lockable main switch. Buttons to raise or lower the barrier shall be provided. 6.2.1 Construction. The control station shall be mounted in a weather resistant, minimum rating NEMA 4 (IEC IP65), electrical enclosure. All connection points shall be clearly identified and coded to the applicable Delta drawing. 6.2.2 Voltage. The remote control panel shall operate on 24 volts. 6.2.3 *Panel shall be equipped with a timer circuit to notify the operator via an annunciator "squealer" that the Barrier has been left in the up position for too long a time period. The time interval shall be customer selectable. Copyright 2001 Delta Scientific Corporation Page 3 of 5

6.3 Position Indicating Lights. The Barrier shall be supplied with a limit switch to actuate when the Barrier is securely down. The limit switch shall operate panel lights to indicate the Barrier secure and not secure condition. 8.0 QUALITY ASSURANCE PROVISIONS 8.1 Testing. Upon completion, the Barrier system will be fully tested in the manufacturer's shop. The following checks shall be made: 8.1.1 Identification. A nameplate with manufacturer's name, model number, serial number and year built shall be permanently attached to the barrier. 8.1.2 Workmanship. The Barrier shall have a neat and workmanlike appearance. 8.1.3 Dimensions. Principle dimensions shall be checked against drawings and ordering information. 8.1.4 Finish. Coatings shall be checked against ordering information and shall be workmanlike in appearance. 9.0 PREPARATION FOR SHIPMENT 9.1 The Barrier system shall be crated or mounted on skids as necessary to prevent damage from handling. The shipping container(s) shall be of sufficient structural integrity to enable the assembly to be lifted and transported by overhead crane or forklift without failure. 10.0 DISCLAIMER Please note - careful consideration must be devoted to the selection, placement and design of a Drop Arm Barrier System installation. Just as in the case of any Barricade system, perimeter security device or security gate that blocks a roadway or drive, care must be taken to ensure that approaching vehicles as well as pedestrians are fully aware of the Barriers and their operation. Proper illumination, clearly worded warning signs, auxiliary devices such as semaphore gates, stop-go signal lights, audible warning devices, speed bumps, flashing lights, beacons, etc. should be considered. Delta has information available on many such auxiliary safety equipment not specifically listed herein. It is strongly recommended that an architect and or a traffic and or safety engineer be consulted prior to installation of a Barricade system. Delta will offer all possible assistance in designing the operating equipment, controls and the overall system but we are not qualified nor do we purport to offer either traffic or safety engineering information. Copyright 2001 Delta Scientific Corporation Page 4 of 5

11.0 PROCUREMENT SOURCE The Model DSC 900 Transportable Rising Plate Barrier System shall be purchased from: DELTA SCIENTIFIC CORPORATION 24901 West Avenue Stanford Valencia, California, 91355, USA Phone (661)257-1800 FAX (661)257-1081 Email info@deltascientific.com www.deltascientific.com DELTA SCIENTIFIC CORPORATION - Virginia Office 7902 Unit 'A' Hill Park Court Lorton, Virginia, 22079, USA Phone (703)541-9114 FAX (703)541-9117 DELTA SCIENTIFIC CORPORATION (UK), LTD. 70 South View Avenue Caversham, Reading Berkshire, RG4 0BB Phone 44 11 894 81133 FAX 44 11 894 81122 Email: deltascuk@aol.com Copyright 2001 Delta Scientific Corporation Page 5 of 5