User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Similar documents
User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

User manual Digital Energy Uninterruptible Power Supply GT Series UPS 6-10 kva

User Manual Uninterruptible Power Supply

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

BRAVER UPS. (Uninterruptible Power System) User s Manual

Informer Compact Series

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

User Manual Rittal PMC UPS 6kVA

Uninterruptible Power Supply

Uninterruptible Power System

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

Technical data sheets

MM-AVR UPS Series User s Manual

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

Installation and Operation Manual Back-UPS BR800/1100CI-IN

Back-UPS CS Back-UPS CS 350

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

Uninterruptible Power System

3000VA 120/208/230VAC

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

Installation and Operation Back-UPS BX550CI-CN

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

CP900EPFCLCD User s Manual K

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Installation and Operation Manual Back-UPS BX1100CI-CN

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Uninterruptible Power System

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

General Precautions. Personnel Precautions

UTILITY INPUT MAINS OUTLET

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

USER MANUAL ONLINE UPS

Digital Energy LP 31 Series

Limousin II User Manual

Technical Data Sheets

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

Uninterruptible Power System

Digital Energy LP 11 Uninterruptible Power Supply kva

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

User s Manual. Automatic Switch-Mode Battery Charger

Technical Data Sheets

Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

Technical Data Sheets

Technical Data Sheets

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

400 Watt Backup Power System Owner s Manual

PR1000ELCD / PR1500ELCD User s Manual

02/15/01. Powerware User s Guide VA.

XPRT 6kVA & 10kVA Online UPS

Technical Data Sheets

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

1. Important Safety Warning

U P S. Uninterruptible Power System Unterbrechungsfreie Stromversorgung

USER MANUAL. Uninterruptible power supply MODEL: 53965,

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

Uninterruptible Power Supply USER MANUAL Version 1.4. Always On UPS Systems Inc. GES-801L, GES-102L, GES-152L, GES-202L, GES-302L

POWERWARE User s Guide VA.

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Liebert PSA VA. Installer/User Guide

c-go 24V/6A 24V/8A 24V/12A

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

Installation and Operation Manual. RTA Series 1KVA to 3KVA Models Uninterruptible Power Systems (UPS)

Technical Data Sheets

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

1. INTRODUCTION. Features:

Eclipse Plus VA UPS and Surge Suppressor User s Manual

Technical Data Sheets

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

Technical data sheets

Liebert GXT MT+ User Manual VA Installer/User Guide

PI1500X Power Inverter User s Manual

USER MANUAL. PowerMust 1080 LCD (1KVA), Online, IEC PowerMust 2016 LCD (2KVA), Online, IEC PowerMust 3024 LCD (3KVA), Online, IEC

CERTIFIED CATEGORY III-3 PROTECTION

SCC-MPPT Solar Charge Controller

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Operating manual UPS - System

Phoenix Inverter

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

USER MANUAL MPS 1-5KW SERIES

Installation and Operation Manual Back-UPS BR1000-CH

SCC-MPPT Solar Charge Controller

Transcription:

GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 51 44 www.gedigitalenergy.com GE imagination at work

GB User Manual Digital Energy Uninterruptible Power Supply ML Series UPS Please read these instructions carefully before installation and start-up of the Digital Energy ML Series UPS. Keep this manual in a safe place for future reference. CONTENTS 1 INTRODUCTION... 2 1.1 Introduction 1.2 Safety Rules 1.3 Transport / Storage 2 INSTALLATION... 2 2.1 Installation Rules 2.2 Installation Procedure 3 OPERATION... 4 3.1 Start-up 3.1.1 Start-up, mains available 3.1.2 Start-up, mains not available ( battery start ) 3.2 Use: Normal Operation 3.2.1 Normal operating conditions 3.2.2 Self test 3.2.3 Auto-off (no-load shutdown) 3.2.4 Switching off 3.3 Use: Status and Alarm Indications 3.3.1 Charger on 3.3.2 Normal operation 3.3.3 On battery 3.3.4 Battery low 3.3.5 Replace battery 3.3.6 Overload 3.3.7 Self test 4 COMMUNICATION... 6 5 MAINTENANCE... 7 5.1 General 5.2 Fuses 5.3 Batteries 5.3.1 General 5.3.2 Battery replacement 6 TROUBLESHOOTING... 8 7 SPECIFICATIONS... 9 General Electric. All rights reserved; reproduction without permission prohibited. This manual may be subject to change; no liability can be accepted for any error or omission. modifications reserved 2 User manual ML Series 350-1000 VA UPS 1.0 (GB)

1 - INTRODUCTION 1.1 Introduction The GE (General Electric) Digital Energy ML Series UPS, an uninterruptible power supply, protects your equipment from all forms of power interference, including complete power failures. 1.2 Safety Rules CAUTION: RISK OF ELECTRICAL SHOCK. The UPS contains batteries. The appliance outlets may be electrically live, even when the UPS is disconnected from the mains. The UPS contains potentially hazardous voltages. Do not open the UPS, there are no user serviceable parts inside. Apart from battery replacement on the ML 350/500/700 models, all maintenance and service work should be performed by qualified service personnel. Always isolate the UPS from the mains during battery replacement. 1.3 Transport / Storage No liability can be accepted for any transport damage when the equipment is shipped in nonoriginal packaging. Before storing, charge the batteries for at least 24 hours. Store the UPS in a dry location, storage temperature must be within -20 +45 C. If the unit is stored for a period exceeding 3 months, optimal battery lifetime is obtained if the storage temperature does not exceed 25 C. Be sure that the UPS is switched off, and that no cable is connected to the interface port. If the unit is stored for a period exceeding 3 months, the batteries must be recharged periodically. Connect the unit to a wall outlet for a period of approx. 48 hours, minimum every 3 months. 2 - INSTALLATION The shipping box contains a Digital Energy ML Series UPS, a power cord, a computer interface cable, a CD ROM and this manual. After unpacking, inspect the UPS for damage. If you find any damage please immediately notify the carrier and place of purchase. IMPORTANT: Before making any connection and switching on the Digital Energy ML Series UPS, please check the following conditions: your mains supply is 220-240 Volts and 50 Hz, and the total power demand of the connected equipment does not exceed the rated output power of the UPS (indicated on the rear panel). 2.1 Installation Rules The UPS is intended to be used in normal domestic and office situations. Protect the UPS, according to the wiring rules, with a 16A D-type fuse. The UPS must be powered from a single phase grounded wall outlet. Do not use extension cords. Avoid locations that are excessively humid, near water, near heat sources or in direct sunlight. The ambient temperature should not exceed 40 C. Optimal battery lifetime is obtained if the ambient temperature does not exceed 30 C. It is important that ventilation air can move freely around and through the unit. Do not block the air vents. Do not plug appliances such as electric heaters, toasters and vacuum cleaners into the UPS. The UPS output can be used only for electronic loads such as computers and telecommunications equipment. Be careful when connecting laser printers: be sure that the demanded power does not exceed the capacity of the UPS. modifications reserved 3 User manual ML Series 350-1000 VA UPS 1.0 (GB)

2.2 Installation Procedure ML 350-700 ML 1000 1. Switch off your computer, and unplug it from the socketoutlet. 2. Disconnect the power cord from the computer (rating 250Vac/10A) and connect this cord to the male input socket (2) at the rear of the UPS (figures on the right show simplified ML 350-700 model). 3. Using the output cord provided, connect the computer to the appliance outlets (3) of the unit. 4. Connect the mains cord of the UPS to a working, grounded AC wall socket outlet. The green LED LINE will blink now: mains power is available and the batteries are charging. 5. For best results, allow the UPS to recharge the batteries for a period of approx. 10 hours. It is acceptable to use the UPS without first charging the battery, but the runtime may be reduced. 6. For advanced communication possibilities, the RS232 interface port (4) can be connected to a computer system. See chapter 4. modifications reserved 4 User manual ML Series 350-1000 VA UPS 1.0 (GB)

3 - Operation 3.1 Start-up 3.1.1 Start-up, mains available 1 Press keypad ON for 2 seconds LED LINE (already blinking) will illuminate continuously now. 2 The equipment connected to the UPS can now be switched on. 3.1.2 Start-up, mains not available ( battery start ) If the mains input is absent (power cord not connected, or mains failure): 1 Press keypad ON for 2 seconds until LED BAT illuminates. The UPS operates on battery: it discharges the batteries. 3.2 Use: Normal Operation 3.2.1 Normal operation conditions: the mains supply is present, the UPS is on, the load does not exceed the capacity of the UPS and the operating temperature is below alarm level. AVR (Automatic Voltage Regulation): If the quality of the incoming mains is poor, the AVR boosts a low incoming voltage or reduces a high one. The load receives a voltage within the normal range (see chapter 7). 3.2.2 Self test (UPS operation and battery condition) In case of a system failure the output voltage can be lost. It is therefore recommended to switch off the load before performing a self test. See chapter 6. 1 During normal operation, press keypad ON for 2 seconds. 2 If the battery does not pass the self test, a replace battery alarm is given. See 3.3. 3.2.3 Auto-off (no-load shutdown) When mains is not available (mains failure or battery start) the UPS will switch off when the load is less than 5% of the maximum load. In this way unnecessary discharging of the batteries is avoided. The unit will automatically turn on again when mains power is restored. The no-load shutdown function cannot be de-activated. 3.2.4 Switching off 1 Press keypad OFF for 2 seconds. 2 If electric isolation is required, unplug the power cord from the wall outlet. modifications reserved 5 User manual ML Series 350-1000 VA UPS 1.0 (GB)

3.3 Use: Status and Alarm Indications o status indications the operating mode! low priority alarms abnormal operating situations!! high priority alarms situations in which the actual output voltage of the UPS is no longer guaranteed; immediate action should be taken O O!!!!!!!! O Charger on (3.3.1) Normal operation (3.3.2) On battery (3.3.3) Battery low (3.3.4) Replace battery (3.3.5) Overload on mains (3.3.6) Overload on battery (3.3.6) Self test (3.3.7) SITUATION LINE BAT BUZZER Mains on. UPS output off Mains on. UPS output on Mains off or abnormal, UPS output on UPS on battery, battery under drained condition Mains on, UPS output on. UPS has failed to pass the previous self test Mains on, output power > 105% of the rated capacity. Mains off or abnormal, Output power > 105% of the rated capacity. Mains on, unit switches to battery mode for 6 secs to check the bat. condition Green blinking 1x /sec Green on Green on (mains mode) Green blinking 1x /sec (standby mode) Green on Green on Operating modes and corresponding indications, see 3.3.1 3.3.7. Red on Red on Red blinking 1x /30 sec Red on Red on Beeps 1x /4 sec Beeps 1x /sec Beeps 1x /30 sec Continuous Continuous RESET BUZZER Possible* Not possible Not possible Not possible * Reset Buzzer alarm: Press keypad ON for 2 seconds. Only the actual buzzer is muted; a next alarm re-activates the buzzer. A buzzer reset does not affect the computer interface alarm. 3.3.1 Charger on Mains on, UPS output off, the batteries are charging. 3.3.2 Normal operation Mains on, UPS output on, see also 3.2.1. modifications reserved 6 User manual ML Series 350-1000 VA UPS 1.0 (GB)

3.3.3 On battery The UPS uses the energy stored in the batteries: see chapter 7 Batteries - autonomy. The UPS will shutdown after the batteries have been discharged (automatic restart), or if keypad OFF is pressed for >2 seconds (manual restart required) or if a UPS shutdown command is given by the computer (automatic restart). 3.3.4 Battery low (end of autonomy) The batteries are nearly discharged. Controlled shutdown of your computer equipment should be completed within 1 minute. 3.3.5 Replace battery The battery is bad. Perform the self test again (see 3.3.7) to confirm the replace battery condition. The alarm only goes out after the next self test: if the battery has either been sufficiently charged (discharged battery) or replaced by a new one (worn out battery). See also 5.3. 3.3.6 Overload on mains/battery The demanded power of the equipment exceeds the UPS s rated output power. If the load exceeds 150% of the rated power: during battery operation, the UPS output will be switched off immediately during mains operation, the UPS output will be switched off after 30 seconds. 3.3.7 Self test The self test can be started manually: when the UPS operates in mains mode press the ON button for 2 seconds. During the test the unit will switch to battery operation for 6 seconds to check the battery condition. After 6 seconds the unit will switch back to normal operation: mains mode. See also 3.2.2. 4 - Communication The RS232 port is a plug-in interface port (4-pin, RJ-11, 4P-4C) which enables advanced communication between the UPS and the computer. Use UPS software for unattended operation of workstations, power quality related data logging, shutdown notification and control, auto-restart, diagnostics, and battery conservation features. We strongly recommend using only original GE Digital Energy software in combination with the RS232 interface port. For specific information on GE Digital Energy s connectivity products please contact your local dealer or Internet: www.gedigitalenergy.com The communication port is available as long as the UPS is ON. Pin # Function 1 Tx 2 Rx 3 No connection 4 GND RJ-11 4P-4C ML 350-700 ML 1000 modifications reserved 7 User manual ML Series 350-1000 VA UPS 1.0 (GB)

5 - Maintenance 5.1 General The UPS is virtually maintenance free: take care of proper environmental conditions and keep air inletsoutlets free of dust. Please read 2.1. 5.2 Fuses If the AC input fuse (1) is defective, be sure it is replaced by a compatible fuse from the same make and type. Fuse ratings: see chapter 7. 5.3 Batteries 5.3.1 General The service life of the battery is up to 6 years. As a healthy battery is critical to the UPS, keypad ON allows a battery test (3.2.2). When the condition of the battery is critical, a replace battery alarm will be given (see 3.3). Charge the batteries for at least 10 hours, switch the UPS off and back on, and perform a self test. If the alarm persists replace the batteries as soon as possible. 5.3.2 Battery replacement Warning: first read the safety rules in section 1.2. When replacing the batteries, use the same number and voltage(v)/capacity(ah). Proper disposal or recycling of the batteries is required. Refer to your local codes for disposal requirements. Never dispose of batteries in a fire: they may explode. Do not open or mutilate batteries: their contents (electrolyte) may be extremely toxic. If exposed to electrolyte, wash immediately with plenty of water. Avoid charging in a sealed container. Never short circuit batteries. When working with batteries, remove watches, rings or other metal objects, and only use insulated tools. Battery replacement procedure (ML 350/500/700) NOTE: This procedure refers to the ML 350/500/700 models only. The batteries of the ML 1000 are not user replaceable, please contact your dealer. 1 press keypad OFF and remove the UPS input power cord from the AC mains supply 2 remove UPS front panel (two screws on bottom side) 3 pull out the battery and disconnect the battery wires 4 connect the new battery (black -, red +); small sparks can occur, this is normal 5 reinstall the new battery, do not pinch or clamp the wires 6 reinstall UPS front panel. modifications reserved 8 User manual ML Series 350-1000 VA UPS 1.0 (GB)

6 - Troubleshooting Whenever a malfunction occurs, first check external factors (e.g. connections, temperature, humidity or load) to determine whether the problem is caused by the unit itself or by its environment. Subsequently check the input fuse: it may be blown. If so: replace the fuse (see 5.2) and be sure that the UPS is not overloaded. The following chart is a simple troubleshooting checklist only. If the suggested solution does not succeed, or if the information is insufficient to solve the problem, please contact your dealer or consult www.gedigitalenergy.com. PROBLEM POSSIBLE CAUSE SOLUTION Blown input fuse No output voltage during self test (3.2.2) Output overload System failure System failure Only battery start possible Blown input fuse See above No communication between computer and UPS UPS operates on battery though mains is present Continuously sounding buzzer mains present Continuously sounding buzzer mains not present UPS does not provide the expected back-up time, no alarm replace battery Blinking LED BAT, intermittent buzzer UPS output switches OFF Computer interface problem Blown input fuse Very high, low or distorted mains voltage UPS overload UPS overload in battery mode Weak battery: recent outage or worn out battery Battery test just after installation or mains failure Reduce load, replace fuse Please contact your dealer or consult www.gedigitalenergy.com Please contact your dealer or consult www.gedigitalenergy.com Check interface cable and attached computer. See above Check mains voltage, contact qualified electrician Reduce load Reduce load Charge the battery. If the battery is near the end of its service life, consider replacing the battery even if the replace battery alarm is not yet active. Allow the UPS to recharge the batteries Weak battery Read 5.3 Battery depleted during mains failure: end of runtime Wait until mains returns Load is less than 5% of rated output and no mains power is present (no-load shutdown Wait until mains returns function is active) Load is more than 150% of rated output Reduce load modifications reserved 9 User manual ML Series 350-1000 VA UPS 1.0 (GB)

7 - Specifications ML Series model : 350 500 700 1000 Ratings Voltage Amperes (VA) / Watts (W) : 350 / 210 500 / 300 700 / 420 1000 / 600 Input AC input voltage (Vac) : 220-240 AC input voltage window (Vac) (mains) : 140-300V 140-300V 140-300V 160-265V Maximum AC input voltage (Vac) : 350 Minimum start-up AC voltage (Vac) : 150 150 150 170 Input frequency (Hz) : 50 Input frequency range : nominal ± 10 % Typical no-load power consumption, normal operation (W) : 12 12 27 27 AC input current (A) : 2.5 3.6 5 6.3 AC input fuse (A) : 5 5 6.3 10 Output AC output voltage (Vac) : 230 (suitable for 220-240 Vac loads) AC output voltage tolerance : nominal ± 5% (before battery low) Output frequency (Hz) : 50 Output frequency stability (Hz) : < ± 0.1 (battery operation) Output waveform : step sine wave Power factor : 0.6 (0.7 at 90% load) Transfer time (ms) : typically 4, max 10 Buck/Boost voltage regulation : if the input voltage is within the input voltage window, the output voltage varies between 198-265Vac Batteries (ratings given for 25ûC) Nominal voltage (Vdc) : 12 12 24 24 Number x capacity (Ah) of batteries : 1x5 1x7 2x5 2x7 Type : 12Vdc, sealed lead acid, maintenance free Service life : up to 6 years (depending on use) Recharge current (A) : 0.5 0.7 0.5 0.7 Battery recharge time for 80% capacity (hours, approximation) : 3 Runtime in minutes VA / Watts 100/60 25 40 60 85 350/210 3 8 14 24 500/300-3 7 11 700/420 - - 3 7 1000/600 - - - 3 General Weight (kg) : 6.5 7.5 11 13 Dimensions (hxwxd, mm) : 150x110x300 150x110x420 150x110x450 Enclosure / protection : steel-plastic / IP20 Colour (operating panel / case) : RAL 9006 (aluminium) / RAL 7035 (light grey) Environment Safety : EN 50091-1-1 (EN 60950) Electromagnetic compatibility : EN 50091-2 Ambient temperature : -10 to +40ûC; Sound at 1 meter : < 35 db(a) Maximum relative humidity : 95% (non-condensing) modifications reserved 10 User manual ML Series 350-1000 VA UPS 1.0 (GB)