Port Flow Rate/ Function Series Actuators Page Number Size Factor

Similar documents
3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

Bulletin 14CAN Specialty & Control Valves

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

EVP SERIES PROPORTIONAL CONTROL VALVES

EAGLE SERIES VALVES E3 AND E4 SERIES. A Solenoid coil is available in AC or. B Manual override plunger provides. C Valve body is tapped #10-32 and may

ua ir e CONTROL VALVES Clippard Minimatic miniature valves and associated products have evolved into a widely used system of fluid power control devic

Control Valves & Valve Accessories

ISO 5599/ Series Technical and Operating Data

1/8 NPT (F) 1/8 NPT (F)

Solenoid Valves & Accessories. Cylinder Control Bases. Features. Performance Data. Materials

Electrical Interface Dimensional Drawings Connector Kits

Valves, Fittings, and Manifolds Catalog. We make things MOVE

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

Performance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port.

DE- OUT OUT DE- OUT OUT DE- SERIES MODEL E21 2-WAY NORMALLY OPEN CONDUIT HOUSG (700) 235 (0) 1 (3) (1) (700) 235 (0) 1 (3) (1) E21G7XC

The H Series Leak-Proof, High-Pressure Valves Versa Products Company has been supplying high quality pneumatic and hydraulic directional control valve

STC Solenoid Valve List Price

G & J SERIES HIGH FLOW SPOOL VALVES

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

Series 1, 2 & 6 Options selector. Port 4 = 1/8" NPT 5 = 1/4" NPT (Series 6* only) 7 = #10-32 UNF 8 = 1/4-28 UNF

N1-DP N2-DP. External Pilot

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

M S S * A

Control & Power, Inc

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

AIR-MITE AIR-MITE DEVICES, INC W. MONTROSE AVENUE CHICAGO, ILLINOIS PHONE: 773/ FAX: 773/

EI, EIO INTRINSICALLY SAFE VALVES

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

WDV-2 2-way normally closed poppet with air pilot. When valve closes a spring biased internal piston draws back a small volume on outlet side (approx.

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

Direct solenoid and solenoid pilot operated valves

3 Way/2 Position Valves

Clippard offers more types of miniature pneumatic cylinders for the MINIMATIC CYLINDER

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

PNEUMATIC VALVES Composite, round line repairable and disposable, and NFPA square interchangeable AND MOTION CONTROL

Valvair Sprint TM Pneumatic Valves Solenoid & Pilot-Operated Directional Spool Valves. Catalog VAL-VS-E/USA April 2004

PROCESS & AUTOMATED VALVES

COILS, CONNECTORS, SOLENOID VALVES

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

Miniature Multimedia Valves

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

2012 Series Solenoid Pilot Actuated Valves

Fluidline Components, Inc. 638 S Rochester Road Clawson, MI Way & 4-Way Valves

LIMIT SWITCH Axiom - AX

2035 Series Solenoid Pilot Actuated Valves

Technical Information Features Fast Response - Bubble Tight Sealing Small Size - 4 Inches High Single Solenoid - Only 3 Moving Parts Pilot Interchange

2-Way/2 Position Valves

2002 Series Solenoid Air Pilot Actuated Valves

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

The following valve actuators are compatible with all Clippard MAV, MAVO, MJV, MJVO, ES-1, & FV series valves.

SELECTION CHARTS. 4-Way Valves. 112 Clippard Instrument Laboratory, Inc Toggle Valves. Stem Valves. Momentary/Detented

FITTINGS CHEST FITTINGS CHEST. Get organized with the Pneuforce Fittings Chest!

High Pressure Solenoid Valves

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control

EI, EIO INTRINSICALLY SAFE VALVES

Heavy Duty Bench Top Presses

acting, spring return, spring extend and double rod models. Hall Effect sensors and magnetic piston versions are also available.

SELECTION CHARTS 100 Ports Order No. Style psig/6 bar Inlet Outlet Exhaust 112

VAL /4" to 2" Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves. Solenoid pilot operated spring return inline valves with nonlocking

Bulletin H-Tech 03 High Pressure Valves Series H

Solenoid Valves & Accessories. Incorporating Solenoid Valves in. Custom Products. Solenoid Operated. Custom Products

Hi-Cyclic Magna-Cycle Valves

Control Valve Specifications

External Pilot. Base Model Stacking Option Voltage Number In Stack

HOW TO USE THE ALKON DOT PUSH IN FITTING

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

Manifolds. 4 Inline 4 Dual Air 4 Junction Blocks 4 Terminal Blocks 4 Aluminum, Brass, Stainless Steel, Nylon & Polypropylene

Transmitters: Relay Valve VR4151/4152

Simultaneous Electrical / Pneumatic Connection to Manifold 1/4 or 6mm Integral Push-In Fittings. AC or DC Circuit Board

G & J SERIES HIGH FLOW SPOOL VALVES

LIMIT SWITCH Axiom - AX

KRONES DIRECT REPLACEMENTS

Versa exercises diligence to assure that information contained in this catalog is correct, but does not accept responsibility for any errors or omissi

SMS Solid Stainless Cylinders

SV SOLENOID OPERATED

Motorised Valve Range

Catalog 080-/USA Notes Vacuum Control Valves

SERIES BCS STRETCH ROD CYLINDERS

SELECTION CHARTS. 3-Way Valves. 110 Clippard Instrument Laboratory, Inc Toggle Valves. Momentary/Detented

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

LIMIT SWITCH Axiom - AX

DRV2-080 Adjustable, Direct-Acting Relief Valve

SPARE PARTS PRICE LIST SEAKEEPER SERIES

Transmitters: Relay Valve

Manifold Valve Accessories

Proveedor Integral de Soluciones para la Industria. Desde1963

PACKED SPOOL 4-WAY DIRECTIONAL CONTROL VALVE.

Technical Data... 3 How to Order... 4 Dimensions... 5 Inline Mount Valve... 6 Manifold Dimensions and Part Numbers... 6

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

36EFC. Series & EFC Valve Package

Table of Contents General Specifications, Available Mountings... 1 Introduction... 2 Application Examples... 3 Features... 4 Theory of Operation... 5

Parker Autoclave Engineers: Fluid Components Product Catalog. February Valves, Fittings and Tubing. Pressures to 150,000 psi (10,000 bar)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Solenoid pilot operated spring return inline valves with nonlocking overrides, 120V, 60 Hz, and cablegrip connector

SECTIONAL BODY. Model SV. Directional Control Valves VALVES STANDARD FEATURES SPECIFICATIONS. Parallel or Series Circuit Construction ...

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

SMA Aluminum Cylinders

Transcription:

Section dex Port Flow Rate/ Function Series Actuators Page Number Size Factor 0- Cv = 0.05 Way Modular Solenoid. -. & to Way Manifold /8 NPT Cv = 0. Way, Position Modular /8 NPT Cv = 0.05 Way Hex Solenoid.5.6 & to Way Body / NPT Cv = 0. /8 NPT Cv = 0.7 Way 8 Manual.7-.8 Way Mechanical.7-.8 Way, Position Pilot.7-.8 Solenoid.9-. / NPT Cv =.0 Way Manual.-.6 Way, Position Mechanical.-. Way, Position Pilot.-.5 Solenoid.7-. / NPT Cv =.0 Way M Manual. Stacking Way, Position Mechanical. Pilot. Solenoid.0 /8 NPT Cv =.0 Way Manual.-.6 Way, Position Mechanical.-. Way, Position Pilot.-.5 Solenoid.7-. /8 NPT Cv =. Way A Manual.-.8 & to Way, Position Pilot / NPT Cv =.9 Way, Position Solenoid Manifold /8 NPT Cv =. Way 8 Manual..8 to Way, Position Pilot Cv =. Way, Position Solenoid / NPT Cv =. Way Manual..8 to Way, Position Pilot Cv =. Way, Position Solenoid / NPT Cv = 6. Way B Manual..8 High Flow Way, Position Pilot Solenoid Note: Operating Temperature references for 8 Series and Series valves described on pages.8 and.. Standard catalog models are suitable for operation in intermittent low temperatures in a range of 0 to + F. A custom aluminum spool may be substituted when long-term application temperatures are expected to be 0 to + F. These should be limited to manual or mechanical actuation, not spring return. Consider that actuation force may exceed catalog specs and that spring return models may not be reliable at these low temperatures. Please consult factory. For long-term, continuous operation in a range of +50 F to +80 F, the Viton seal option can provide the benefits of reliable leak-free operation and extended durability. For applications exceeding +80 F, please consult factory.. -8-08

Series Section dex Quick Page No. Modular Manifold.... Hex Body....5 8............................7............................ M................................. A.... 8........................................................ B.... -8-0.

0- & /8 NPT, & Way Modular Manifold Miniature 5 STYLE Solenoid Valves, or Way - Modular Manifolding, or Way - Single Mounting Time Proven Space Saving Reliable, and Way Solenoid Valves with 0- or /8 NPT ports are available in singular or modular manifold versions. Any combination of function and ports can be combined in the same manifold stack to save time, space and plumbing. With pressure manifold plugging, two or more pressure ranges and/or medias can be controlled in the same stack. For Each Valve Specify: EXAMPLE Basic Model Number 0-M See Chart Below Letter for Housing -C C Conduit, G Grommet, F DIN Number for Seat - See orifice information chart below Options See option formation below Volts & Hertz 0/60 See solenoid information Page.9 Example: Way modular mounting with manifold inlet, /8 NPT inlet, 0- Cylinder Port, Conduit Housing, /6 Seat, 0 Volts/60 HZ. Model Number = 0-M-C-, 0/60 For Complete Assembled Banks Specify: Quantity of assembled Banks Valve models (start left to right, see photo above) Mounting brackets, if desired #0 Example Using the photo above Bank consisting of: -M-C- 0/60 0-M-F- 0/60 0-M-G- 0/60 -M-C- 0/60 Pair #0 Mounting Brackets inlet Cylinder Basic Function Port Port Model No. Valves for Way N.C. /8 NPT /8 NPT -S dividual Way N.C. /8 NPT /8 NPT -S Mounting & Way 0-0- 0-S-0 dividual Way /8 NPT 0-0-S-8 let Way /8 NPT /8 NPT -S Valves for Way N.C. 0-0- 0-SM Modular Way N.C. 0-0- 0-SM Mounting & dividual let Valves for Way N.C. /8 NPT 0-0-M Modular Way N.C. /8 NPT /8 NPT -M Mounting & Way N.C. /8 NPT 0-0-M Manifolded Way N.C. /8 NPT /8 NPT -M let (Pressure Way /8 NPT 0-0-M Manifolded) Way /8 NPT /8 NPT -M All Mountings Way Normally Open use Way & Plug N.C. port Option information Viton Seals for media compatibility specify Option -V Coils & Housing, See page.9. Low Pressure Spring - Way Only - See Operating Pressures. Pro-Coat (Electroless Nickel Plate) Option -N, See page.0. Special Bank Assembly (Plugs, Fittings, Wire Terminals) See Pg iii. Normally Open (N.O.) & Way Valves - Use Way Valve & Plug N.C. Port. Orifice information Operating Pressures Applies to all Way 0 and series valves. See Orifice formation below for pressure ranges of & Way valves. Standard Spring 0 psi Minimium 50 psi Maximum with #, /6 orifice. See Orifice formation below for Maximum with other orifices. Optional Low Pressure Spring 0 psi: 0 psi Minimum 5 psi Maximum 5 psi: 5 psi Minimum 60 psi Maximum Accessories Mounting Brackets Part # 0. Connectors for Mini-DIN F, See page.0. SM-0 Muffler, See page.. Available Orifices and Equivalent Maximum Pressure Ratings for AC Voltages (DC Ratings Slightly Lower) CFM Flow @ Cv Factor Way N.C. Way N.C. Way 00 psi 50 psi Number 0 /.0 500 psi 00 psi 50 psi. 0.9 Number /6.055 00 50 50.5.0 Number /6.075 00 00 00 5.8. Number /.56 00 60 80 9.0 6.0 Number /8.0 75 0 Not Available Not Available 8.0. --06

0- & /8 NPT, & Way Modular Manifold MODELS 0-M, 0-M, 0-M, -M, -M & -M Supply pressure can be connected to either or both ends of the stack. Due to the fact that the supply pressure port on all M valve bodies is tapped on both sides, the pressure manifold can be plugged at any point within the stack. This allows you to supply the stack with two different pressures or media, one from each end. For more than two inputs a port block can be provided in midstack. Spacers can be included for applications requiring the larger EXPLOSION PROOF operator. Contact Fabco-Air with your specific requirements..8 Typ..0 Dia. Places. Typ..56 Typ. 0- EXH Port #0 Mounting Bracket (Pair) 0-M Dual Cylinder Ports 0- NC CYL Ports.8 0-M.55 Dual Cylinder Ports 0- NC CYL Ports -M /8 NPT CYL Port.55 Ref..8.55 -M /8 NPT CYL Port.5.80.8 Typ..8 Typ. See Housing Details on Page.9.9 Typ..9 Typ. [ (Quantity of Valves) x.] +.75 SM-0 Muffler, See page.....8.55 0-M 0- NO CYL Port 0- NC CYL Port..7.0.8.55 -M /8 NPT NO CYL Port /8 NPT NC CYL Port.7.6.5.0.68.55 Typ. MODEL 0-S-0 (0- let Port) MODEL 0-S-8 (/8 NPT let Port).7.78...8.8 0- NC CYL Port.68.0 Dia. Places. Note: Mounting screw heads may restrict housing rotation..0 See Housing Details on Page.9 0- EXH Port INLET PORT 0-S-0 0-0-S-8 /8 NPT 0- NO CYL Port Spring Cap.7.8.55. 0- EXH Port Do Not Restrict Spring Cap MODEL -S (-Way), -S (-Way).7 /8 NPT -S IN -S Cyl.78...8.8 /8 NPT -S Cyl -S IN.67.0 Dia. Places. Note: Mounting screw heads may restrict housing rotation..0.79.9 0- EXH Port Do Not Restrict See Housing Details on Page.9 0- EXH Port Spring Cap 8-6-0.7 Spring Cap.56 MODEL -S.56.78...78..0..9.8.68.8 /8 NPT NC CYL Port.7.8.55.8.0 Dia. Places. Note: Mounting screw heads may restrict housing rotation. 0- EXH Port Do Not Restrict.7 See Housing Details on Page.9.0 0- EXH Port.8 /8 NPT NO CYL Port 0- EXH Port Do Not Restrict.80.55.8 Typ..56. Typ..56 Typ. 0-SM.55 0-SM. MODEL 0-SM (-Way), 0-SM (-Way).0 Dia. Places 0-0-.9 Typ. 0- CYL Port 0- IN Port.8 Typ..8 0- IN Port (0-SM) 0- CYL Port (0-SM).8 Typ. See Housing Details on Page.9.9 Typ. [ (Quantity of Valves) x.] +.75 0- EXH Port (0-SM).0 #0 Mounting Bracket (Pair).80.68.89.

/8 & / NPT & Way Valves Hex Body Body Hex aluminum, black anodized - Different porting styles. Media Air, water & other fluids compatible with standard Buna-N seals and aluminum. Power See page.9 BODY STYLE De- De- WAY NORMALLY OPEN Hex Body 5 STYLE Solenoid Valves SIDE PORT IN OUT Basic Model 0- /8 8- - -NO /8 /8 8- - -NO 0- / - - -NO /8 / - - -NO De- De- BODY STYLE WAY NORMALLY CLOSED SIDE PORTS BODY STYLE FEMALE BOTTOM PORT BODY STYLE FEMALE BOTTOM PORT IN OUT Basic Model 0- /8 F-8- - -NO /8 /8 F-8- - -NO 0- / F-- - -NO /8 / F-- - -NO Operating Temperature: 0 F ( 8 C) to +0 F (0 C) ambient. 0 F ( 8 C) to +50 F (65 C) media. Voltages See page.9 Operating Pressure See chart with orifice information ternal Parts Stainless Steel IN OUT Basic Model /8 /8 8- - / / - - IN OUT Basic Model /8 /8 F-88- - /8 / F-8- - / /8 F-8- - / / F-- - BODY STYLE FEMALE BOTTOM PORT BODY STYLE FEMALE BOTTOM PORT De- IN OUT Basic Model /8 0- FX-8- - -NO /8 /8 FX-8- - -NO / 0- FX-- - -NO / /8 FX-- - -NO De- IN OUT Basic Model /8 /8 FX-88- - /8 / FX-8- - / /8 FX-8- - / / FX-- - De- De- BODY STYLE MALE BOTTOM PORT BODY STYLE MALE BOTTOM PORT IN OUT Basic Model 0- /8 08- - -NO /8 /8 08- - -NO 0- / 0- - -NO /8 / 0- - -NO IN OUT Basic Model /8 0- X-8- - -NO /8 /8 X-8- - -NO / 0- X-- - -NO / /8 X-- - -NO De- De- BODY STYLE MALE BOTTOM PORT BODY STYLE MALE BOTTOM PORT IN OUT Basic Model /8 /8 88- - /8 / 8- - / /8 8- - / / - - IN OUT Basic Model /8 /8 X-88- - /8 / X-8- - / /8 X-8- - / / X-- - HOW TO ORDER EXAMPLE Basic Model Number X88 See Model Charts sert Letter for Housing at Number for Orifice at - All Way EX Orifices are /6 Options -C C Conduit, G Grommet, F DIN See Solenoid formation Page.9 See Chart, Orifice formation See Chart, Option formation Volts & Hertz 0/60 See Solenoid formation Page.9.5 Example: Way N.C., /8 NPT Male Bottom let, /8 NPT Side Cylinder, Conduit Housing, /6 Seat, 0 Volts/60 HZ. Model Number = X88-C-, 0/60 OPTIONS: Specify Suffix /8 NPT Adapter ( Way N.C. Top Exhaust)...-A... See Pg..6 Viton Seals (for media compatibility)...-v Explosion Proof... -EP... See Pg..0 Pro-Coat (Electroless Nickel Plate)...-N... See Pg..0 Spade Electrical Connections See Pgs..9 &.0 Accessories: Solenoid Exhaust Muffler... SM-0... See Page. Connectors for Mini-DIN F... See Pg..0-6-08

/8 & / NPT & Way Valves Hex Body Orifice information Available Orifices and Equivalent Maximum Pressure Ratings for AC Voltages (DC Ratings Slightly Lower) CFM Flow @ Cv Factor Way N.O. Way N.C. Way N.O. Way N.C. 00 psi 50 psi Number 0 /.0 50 psi 500 psi 50 psi 00 psi. 0.9 Number /6.055 5 00 5 50.5.0 Number /6.075 00 00 00 00 5.8. Number /.56 NA 00 NA 60 9.0 6.0 Number /8.0 NA 75 NA 0 NA 8.0 All way (EX) exhaust orifices are /6. All way (EX) exhaust orifices are /6. BODY STYLE WAY NORMALLY OPEN SIDE PORT BODY STYLE WAY NORMALLY CLOSED SIDE PORTS De- Ex Cyl Ex Cyl IN CYL EX Basic Model 0- /8 /8 8- - -NO /8 /8 /8 8- - -NO 0- / / - - -NO /8 / / - - -NO De- Ex Ex Cyl Cyl IN CYL EX Basic Model /8 /8 0-8- - / / 0- - - For optional /8 NPT Adapter add Suffix A De- Ex BODY STYLE FEMALE BOTTOM PORT BODY STYLE FEMALE BOTTOM PORT Cyl De- Ex Cyl Ex BODY STYLE Cyl Ex Cyl IN CYL EX Basic Model 0- /8 /8 F-88- - -NO /8 /8 /8 F-88- - -NO 0- /8 / F-8- - -NO /8 /8 / F-8- - -NO 0- / /8 F-8- - -NO /8 / /8 F-8- - -NO 0- / / F-- - -NO /8 / / F-- - -NO MALE BOTTOM PORT IN CYL EX Basic Model 0- /8 /8 88- - -NO /8 /8 /8 88- - -NO 0- /8 / 8- - -NO /8 /8 / 8- - -NO 0- / /8 8- - -NO /8 / /8 8- - -NO 0- / / - - -NO /8 / / - - -NO De- Ex Cyl Cyl De- Ex De- Ex Cyl Ex BODY STYLE Cyl Cyl BODY STYLE De- Ex BODY STYLE Cyl Ex Cyl Ex Ex Cyl IN CYL EX Basic Model /8 /8 0- F-88- - /8 / 0- F-8- - / /8 0- F-8- - / / 0- F-- - For optional /8 NPT Adapter add Suffix A FEMALE BOTTOM PORT IN CYL EX Basic Model /8 /8 0- FX-88- - /8 / 0- FX-8- - / /8 0- FX-8- - / / 0- FX-- - For optional /8 NPT Adapter add Suffix A MALE BOTTOM PORT IN CYL EX Basic Model /8 /8 0-88- - /8 / 0-8- - / /8 0-8- - / / 0- - - For optional /8 NPT Adapter add Suffix A MALE BOTTOM PORT IN CYL EX Basic Model /8 /8 0- X-88- - /8 / 0- X-8- - / /8 0- X-8- - / / 0- X-- - For optional /8 NPT Adapter add Suffix A BODY STYLE Side Ports BODY STYLE Female Bottom Port BODY STYLE Male Bottom Port.68 0- Port. /8 NPT Port..9 No. 0- x / Deep Mt'g Thds..7. 0- Port.67 /8 NPT Port.56.8.7 /8 NPT Port.6 0- Port.06. --08 Hex Hex Hex See Pg..9 for Housing Details See Pg..9 for Housing Details See Pg..9 for Housing Details.6

/8 NPT, & Way 8 Series /8 NPT Ported, Manual, Mechanical and Pilot Operated Air Valves The Finest in Simplicity, and Way - Position Operation to 50 psi Air Suitable for Vacuum directional flow applications, but NOT for holding vacuum. Short stroke of lightweight Delrin spools provides fast, positive, and reliable response. Air Pilot Standard Way & Way spring return are normally closed. For normally open the actuators may be exchanged end for end or by specifying -0 for - & -0 for -. Minimum pilot pressure: Standard spring...60 psi Light spring (Option -L)... 0 psi Double pilot...0 psi Pilot Bushing /8 NPT Standard. 0- = Option -E Standard or Light Spring Housing 9/6 Hex. 9/6 Hex.8 Note : Specify Normally Open by substituting -0 for - & -0 for -. Way Way Way Single Pilot - Spring Return 8SP- 8SP- 8SP- Double pilot 8DP- 8DP- 8DP- Replacement spool & seals 800-90 800-90 800-90 Light spring, Option -L 0- pilot port, Option -E Air Pilot Amplifier Rod Actuator Roller Cam WAY 0.6.0 Dia. Clearance for #0 Bolt.5. " Delrin piston in aluminum housing meets low pressure requirements. Standard Way & Way spring return are normally closed. For normally open the actuators may be exchanged end for end or by specifying -0 for - & -0 for -. Minimum pilot pressure: Standard spring...0 psi Light spring (Option -L)...7 psi Against 0 psi pilot... psi Stainless steel rod in brass bushing. Standard Way & Way spring return are normally closed. For normally open the actuators may be exchanged end for end or specify by substituting -0 for - & -0 for -. Force to actuate: Standard spring...6.5 lb. Light spring (Option -L)... 5.0 lb. Double Rod... lb. Case hardened steel roller and shaft in hard anodized aluminum housing. Standard Way & Way spring return are normally closed. For normally open specify by substituting -0 for - & -0 for -. Force to actuate: Standard spring...6.5 lb. Light spring (Option -L)...5.0 lb. Double Cam... lb..8..8 0. Way 0. This Way Valve may be used for any Way, Selector or Diverter.6 service..0 Dia. Clearance for #0 Bolt /8 NPT Standard. 0- = Option -E.5 Dia.. Valve Body Dimensions.5.0.58.8.78.5 Dia. 0...5 Stroke.75 Dia..88..88.5 Stroke. Way Way Way Single Pilot (Amplifier) - Spring Return 8SA- 8SA- 8SA- Double pilot - amplifiers 8DA- 8DA- 8DA- Double pilot - amplifier, air pilot 8DAP- 8DAP- 8DAP- When both pilots are pressurized, the amplifier overrides. Replacement spool & seals 800-90 800-90 800-90 Light spring, Option -L 0- pilot port, Option -E Way Way Way Single Rod - Spring Return 8SR- 8SR- 8SR- Single Rod- Pilot Return 8SRP- 8SRP- 8SRP- Double rod 8DR- 8DR- 8DR- Replacement spool & seals 800-90 800-90 800-90 Light return spring, Option -L Way Way Way Single Cam - Spring Return 8CR- 8CR- 8CR- Single Cam - Pilot Return 8CRP- 8CRP- 8CRP- Replacement spool & seals for above 800-9 800-9 800-9 Double cam 8CCR- 8CCR- 8CCR- Replacement spool & seals 800-9 800-9 800-9 Light return spring, Option -L Way - 5 Port 5.6.0 Dia. Clearance for #0 Bolt.5..97.0. 5.67.89.5.7.7.8 Primary Secondary.8 Primary Standard & way spring return models are normally closed. Models with thread in actuators may be converted to normally open by exchanging actuators end for end. Other models require specification and factory assembly. See note. Secondary.8 Primary Secondary way - 5 port May be used as either single inlet - dual exhaust or dual inlet - single exhaust. -6-08

/8 NPT, & Way 8 Series FEATURES OPTIONS Aluminum bar body Anodized black Honed & burnished bore Pressure balanced spool Delrin spool Buna-N seals Operation to 50 psi Way - 5 port may be used as either single inlet - dual exhaust or dual inlet - single exhaust. Prelubed with Magnalube G Grease terchangeability of Parts Cv = 0.7 (. SCFM Free Flow to Atmosphere at 80 psi Supply) Operating temperature + to +80 F; Solenoid controlled models +50 F max. See pages.9 and.. OPERATING TEMPERATURE FOOTNOTE SEE PAGE. Light spring Specify Option -L Viton seals Specify Option -V Spools for bleeder pilot Multiple stacking with or without common inlet. Consult factory. Note : Specify Normally Open by substituting -0 for - & -0 for -. Small Palm Button Un-anodized aluminum button with stainless steel rod in brass bushing. Standard Way & Way spring return are normally closed. For normally open the actuators may be exchanged end for end or specify by substituting -0 for - & -0 for -. Force to actuate: Standard spring... 6.5 lb. Light spring (Option -L)... 5.0 lb. Double Button.... lb..75 Dia..97.5 Stroke Way Way Way Single Button - Spring Return 8PS- 8PS- 8PS- Single Button - Pilot Return 8PSP- 8PSP- 8PSP- Double Button 8PPS- 8PPS- 8PPS- Replacement spool & seals 800-90 800-90 800-90 Light spring Option -L Large Palm Button Red anodized aluminum button with stainless steel rod in brass bushing. Standard Way & Way spring return are normally closed. For normally open the actuators may be exchanged end for end or specify by substituting -0 for - & -0 for -. Force to actuate: Standard spring... 6.5 lb. Light spring (Option -L)... 5.0 lb. Double Button.... lb..5 Dia..9.5 Stroke Way Way Way Single Button - Spring Return 8PL- 8PL- 8PL- Single Button - Pilot Return 8PLP- 8PLP- 8PLP- Double Button 8PPL- 8PPL- 8PPL- Replacement spool & seals 800-90 800-90 800-90 Light spring Option -L Panel Mount Button Hand Lever Palm Button Assembly Phenolic button with plated steel rod in brass bushing; black button standard, red button Option -R. Standard Way and Way assemblies are normally closed with knob in the out position. For normally open specify by substituting -0 for - and -0 for -. Force to actuate: Standard spring... 6.5 lb. Light spring (Option -L)... 5.0 lb. Double Button.... lb. Detented....0 lb. Hardened & plated steel shaft with unique connection to spool results in positive shifting. Standard Way & Way spring return are normally closed. For normally open specify by substituting -0 for - & -0 for -. Force to actuate: Standard spring....0 lb. Light spring (Option -L)....0 lb. Detented....0 lb. Rod Actuator Assembly Spring Housing Assembly () 7/8 Hex x. thick brass nuts included.5 Stroke /-6.8 Dia..75 Dia..8.8.65 6 Lever position when spring returned Most Threaded- Operators are terchangeable Between Ends Way Way Way Spring Return 8PMS- 8PMS- 8PMS- Pilot Return 8PMP- 8PMP- 8PMP- Replacement spool & seals for above. 800-90 800-90 800-90 Detented (Push Pull) 8PMD- 8PMD- 8PMD- Replacement spool & seals 800-9 800-9 800-9 Light spring Option -L Way Way Way Spring Return 8HLS- 8HLS- 8HLS- Detented 8HL- 8HL- 8HL- Replacement spool & seals 800-9 800-9 800-9 cludes factory assembled spool attachments. Light spring Option -L Pilot Bushing No. 800- Large Button No. 800- Small Button Panel Mount Button Assembly For Detented (with Spool) No. 800-7- (W NC) 800-7-0 (W NO) 800-7- (W NC) 800-7-0 (W NO) Above Not interchangeable End for End 800-7- ( Way) For Spring or Pilot Return (No Spool) 800-8 ( or Way, NO or NC, and Way)) -7-08 No. 800- No. 800- Light Spring only (for Option L). No. 800-5 Standard Spring only No. 800-6 Light Spring & Housing Ass'y (for Option -L). No. 800-56 Standard Spring & Housing Assembly. Air Pilot Amplifier /8 NPT Standard No. 8 AMP- /8 NPT Port No. 0 AMP- 0- Port Option -E No. 800-0 0- Port No. 800-8 /8 NPT Port Fabco-Air has the expertise and willingness to design. modify and adapt these valves to your necessary and specific job requirements. Please advise us of your needs..8

/8 NPT, & Way 8 Series /8 NPT Ported 5 STYLE Solenoid Controlled, Pilot Operated Air Valves, & Way - Position Operation to 50 psi Air Options Locking...-MO Non-Locking...-MO External Pilot...-X Light Spring...-L Viton Seals for media compatibility....-v Explosion Proof Operators...-EP See page.0 Dual let - Single Exhaust Way See page.0 Note : Optional Flow Path Features Black anodized aluminum bar stock body Honed and burnished bore Lightweight Delrin spool provides fast, positive, reliable response Buna N seals Operation to 50 psi Coils & housing information see page.9 Cv = 0.7. SCFM free flow to atmosphere @ 80 psi Prelubed with Magnalube -G grease Operating temperature: + F (0 C) to +0 F (0 C) ambient. + F (0 C) to +50 F (65 C) media. Standard catalog models are suitable for operation in intermittent low temperatures in a range of 0 to + F. A custom aluminum spool may be substituted when long-term application temperatures are expected to be 0 to + F. These should be limited to double solenoid actuation. Consider that actuation force may exceed catalog specs and that spring return models may not be reliable at these low temperatures. Please consult factory. Operating Range ternal Pilot Supply (Standard) Standard Spring...60 to 50 psi Light Spring, Option -L...0 to 50 psi Pilot Return (0 psi Pilot)..0 to 50 psi External Pilot Supply, Option -X let Pressure...0 to 50 psi External Pilot Supply, Option -X Standard Spring...60 to 50 psi Light Spring, Option -L...0 to 50 psi Pilot Return (0 psi Pilot)..0 to 50 psi SINGLE SOLENOID To Order Specify: Model Number from chart Options Volts & Hertz (See page.9) way Way Way Normally Normally Normally Normally Closed Open Closed Open Conduit Housing 8CS- 8CS-0 8CS- 8CS-0 8CS- Grommet Housing 8GS- 8GS-0 8GS- 8GS-0 8GS- Male Mini-DIN Housing 8FS- 8FS-0 8FS- 8FS-0 8FS- Replacement Spool and Seals 800-9 800-90 800-9 800-90 800-9 SINGLE SOLENOID - PILOT RETURN Models A pilot return can be substituted for the standard spring return. It may be used in two manners.. For a pulse signal, then pilot return.. As a constant, adjustable force, spring. Supply pilot port with a constant regulated pressure. This will act as a very constant spring against the solenoid controlled pilot signal. The pilot return should be a minimum of 0 psi below the solenoid controlled pressure. To Specify, Substitute P for S in the Model Number. (Example 8CP--0/60) /8 NPT Pilot Port standard. 0- Pilot Port optional, Specify Option -E. Double SOLENOID To Order Specify: Model Number from chart Options Volts & Hertz (See page.9) Operating Range ternal Pilot Supply (Standard) let...0 to 50 psi External Pilot Supply, Option -X let Pressure....0 to 50 psi Pilot Supply....0 to 50 psi.9 way Way Way Conduit Housing 8CC- 8CC- 8CC- Grommet Housing 8GG- 8GG- 8GG- Male Mini-DIN Housing 8FF- 8FF- 8FF- Replacement 800-9 800-9 800-9 Spool and Seals --08

/8 NPT, & Way 8 Series See Housing Details Page.9 WAY 0.6.0 Dia. Clearance for #0 Bolt.5..8.8. 0..5. Max. Standard 5 STYLE Solenoid Operator The solenoid operator is a -way NC valve which, upon receiving an electrical signal, directs a pilot pressure to shift the main valve spool. As standard, the operator is internally supplied with air pressure from the main valve inlet. Also see External Pilot Supply below. See Housing Details Page.9 /8 NPT..5. Max. See Housing Details Page.9 5 STYLE Solenoid Operator with External Pilot Supply Option -X the following listed applications, as well as many others, a proper air supply may not be available from the main valve inlet. For these applications, an external pilot supply port is available (Option -X). A proper air supply to this port then supplies the solenoid with air pressure for piloting the main valve spool. Dual let - Single Exhaust Way. sufficient pressure at main valve inlet. Media, at main valve inlet, other than air. Extremely fast cycling. Option -X is NOT combinable with either Option -MO or -MO Way 0.8..6.0 Dia. Clearance for #0 Bolt.5 Way - Standard: Single inlet - Port # - dual Exhaust 5.6.0 Dia. Clearance for #0 Bolt 5.5 Primary Secondary Spring Return Valves End Operator Normally Closed Normally Open Note : Optional Flow Path: Dual let - Ports # & #5 - Single Exhaust. Use External Pilot Supply (Option -X)..8.58.0 0...8 Primary.8 Secondary Spring Return Valves End Operator Normally Closed Normally Open 0 Spring Solenoid 0 Solenoid Spring 0 Spring Solenoid 0 Solenoid Spring.97..0. 5.67.89.5.7 Primary Secondary -8-0.5. Dia. 5 STYLE Solenoid Operator with This manual override is a -way NC valve that when pushed, directs pilot pressure to shift the main spool. Pressure must be present at main valve inlet for this override to function.. TYPE Suffix LOCKING Push to override; -MO Turn to lock in; Turn back to release. NON-LOCKING Push to override. -MO Spring Return: Standard and Optional Light. Pilot Return: -P See Page.7 Pilot Port /8 NPT Port Standard 0- Port Specify Option -E.8 9/6 Hex 9/6 Hex.0

/8 NPT, & Way 8 Series /8 NPT Ported 58 STYLE Solenoid Controlled, Pilot Operated Air Valves, & Way - Position Operation to 50 psi Air Options External Pilot...-X External Pilot and Viton Seals... -XV Light Spring...-L Viton Seals are available in the main valve only, for media compatibility, and therefore only in conjunction with External Pilot + F (0 C) to + F (50 C). Features Black anodized aluminum bar stock body Honed and burnished bore Lightweight Delrin spool provides fast, positive, reliable response Simplicity Reliability Corrosion resistant construction Buna N seals Operation to 50 psi Solenoid operator information see page. Cv = 0.7. SCFM Free flow to atmosphere @ 80 psi Prelubed with Magnalube -G grease Operating temperature: + F (0 C) to + F (50 C) ambient. + F (0 C) to + F (50 C) media. Standard catalog models are suitable for operation in intermittent low temperatures in a range of 0 to + F. A custom aluminum spool may be substituted when long-term application temperatures are expected to be 0 to + F. These should be limited to double solenoid actuation. Consider that actuation force may exceed catalog specs and that spring return models may not be reliable at these low temperatures. Please consult factory. Operating Ranges, psi # Solenoid # Solenoid 0.9 Watts.5 Watts ternal Pilot Supply (Standard) let Pressure Non Spring Return...0 to 0...0 to 5 Spring Return....60 to 0...60 to 5 Light Spring Option -L...0 to 0...0 to 5 External Pilot Supply, Option -X let Pressure... 0 to 50...0 to 50 External Pilot Supply, Option -X Pilot Supply Non Spring Return...0 to 0...0 to 5 Spring Return....60 to 0...60 to 5 Light Spring Option -L...0 to 0...0 to 5. --08

/8 NPT, & Way 8 Series 58 STYLE Solenoid Valve, Model Number Code 8 F S 0 0 0/60 Series 8 /8 NPT Primary Actuator F = Micro DIN G = Wire leads See page. Function = Way = Way = Way See page.7 Secondary Actuator F = Micro DIN* G = Wire leads* S = Spring** P = Pilot** R = Rod** B = Small Button** L = Large Button** * See page. ** See pages.7 &.8 for details Solenoid Watts = 0.9 Watts =.5 Watts Primary Solenoid Attitude = Upright 90 to Body 5 = line with Body Primary Solenoid 0 = None = Position # = Position # = Position # = Position # Secondary Solenoid Attitude 0 = Other than Solenoid = Upright 90 to Body 5 = line with Body Secondary Solenoid 0 = None = Position # = Position # = Position # = Position # Solenoid Attitude # only # = Upright 90 to Body Volts / Hertz # Solenoid (0.9 Watts) VDC VDC # Solenoid (.5 Watts) /60 VAC 0/60 VAC VDC VDC Options -X = External Pilot -XV = External Pilot & Viton Seals -L = Light Spring Viton Seals are available in the main valve only for media compatability and therefore only in conjunction with External Pilot (+ to 80 F). Example: 8FS--00-0/60 /8 NPT Primary Actuator Solenoid with Micro DIN coil; Secondary Actuator, Spring Return Way Function.5 Watt Solenoid; Primary Solenoid Upright position with in Position #; Secondary Actuator is not a Solenoid; no on Secondary Actuator No Options 0 Volt/60 Hertz. Primary Solenoid Position Section A A.5 Primary Actuator End,, or Way Valve Body Secondary Actuator End Secondary Solenoid Position Section A A See page. for Operator Details See page.0 for Body Details External Pilot Supply Option -X /8 NPT.. Max. A A Side View Spring Return Shown Upright Solenoid Attitude # (Solenoid centerline 90 to Valve Body centerline) External Pilot Supply Option -X.8 /8 NPT.8.5 Primary Actuator End,, or Way Valve Body Secondary Actuator End line Solenoid Attitude #5 (Solenoid centerline inline with Valve Body centerline) Primary Solenoid Position Section B B See page. for Operator Details See page.0 for Body Details B Side View Secondary Solenoid Position Section B B -6-08 B Spring Return Shown.

/ & /8 NPT, & Way, M & Series / & /8 NPT Ported, Manual, Mechanical and Pilot Operated Air Valves The Finest in Simplicity, and Way - Position Operation to 50 psi Air Suitable for Vacuum directional flow applications, but NOT for holding vacuum. Note : Specify Normally Open by The short stroke of the lightweight Delrin spool provides fast, posiitive, and reliable response. substituting -0 for -. Air Pilot Rod Actuator Brass bushing with /8 NPT port. Standard Way spring return is normally closed. For normally open the actuators may be exchanged end for end or by specifying -0 for -. Minimum pilot pressure: Standard spring... psi Light spring (Option -L)... 0 psi Double pilot...0 psi Stainless steel rod in brass bushing. Standard Way spring return is normally closed. For normally open the actuators may be exchanged end for end or specify by substituting -0 for -. Force to actuate: Standard spring...0.5 lb. Light spring (Option-L)...9.0 lb. Double rod... lb. Pilot Bushing 7/8.8 Hex /8 NPT Note: See Stacking (Pressure Manifolded) informnation below. Dia..9.8 Stroke Note: See Stacking (Pressure Manifolded) informnation below Way Way Single Pilot - Spring Return / NPT SP- SP- / Stacking N/A MSP- /8 NPT SP- SP- Double Pilot / NPT DP- DP- / Stacking N/A MDP- /8 NPT DP- DP- Replacement spool & seals 00-90 00-90 Way Way Single Rod - Spring Return / NPT SR- SR- / Stacking N/A MSR- /8 NPT SR- SR- Single Rod - Pilot Return / NPT SRP- SRP- / Stacking N/A MSRP- /8 NPT SRP- SRP- Double Rod / NPT DR- DR- / Stacking N/A MDR- /8 NPT DR- DR- Replacement spool & seals 00-90 00-90 Roller Cam Case hardened steel roller and shaft in hard anodized aluminum housing. Standard Way spring return is normally closed. For normally open specify by substituting -0 for -. Force to actuate: Standard spring...0.5 lb. Light spring (Option-L)...9.0 lb. Cam-Pilot return... lb..8 Stroke.75 Dia..8..5..8 Note: See Stacking (Pressure Manifolded) informnation below Way Way Single Cam - Spring Return / NPT CR- CR- / Stacking N/A MCR- /8 NPT CR- CR- Single Cam - Pilot Return / NPT CRP- CRP- / Stacking N/A MCRP- /8 NPT CRP- CRP- Replacement spool & seals for above 00-9 00-9 Double cam / NPT CCR- CCR- / Stacking N/A MCCR- /8 NPT CCR- CCR- Replacement spool & seals 00-9 00-9 Stacking - Pressure Manifold Selected models of the Series /" air valves can be stacked and pressure manifolded for space and money savings. The valve bodies are bolted together with through tie bolts and the pressure is manifolded with O-Ring seals between the valves. let pressure can be connected to either or both ends of the stack. Due to the fact that the pressure port, on all valve bodies, is tapped on both sides, the pressure manifold can be plugged at any point within the stack. This allows you to supply the stack with two different pressures, one from each end. See Model Numbers in the Air-Pilot Rod Actuator, Roller Cam and Small Palm Button sections of Pgs. and. and Solenoid Valves on Pgs.9 and.0. To Order: Specify the Quantity of each model desired, the Order in which they are to be assembled, and Brackets, if desired. Spring Cap Dimensions Valve Body Dimensions STANdARd SPRiNg.69 Dia..5 LigHT SPRiNg OPTiON -L.5. 7/8 Hex 7/8 Hex Way / Way This Way Valve may be used for any Way, Way, Selector or Diverter service..88.09 0.9.5.0 Dia. Clearance for #0 Bolt.75.9.56. Primary Secondary.78. 0 Way - 5 Port 5.0 Dia. Clearance for #0 Bolt.75.9.5..56.8.9.0..5.88 Primary 5 Secondary Way - 5 Port May be used as either Single let - Dual Exhaust or Dual let Single Exhaust -8-08

/ & /8 NPT, & Way, M & Series Aluminum bar body Anodized black Honed & burnished bore Pressure balanced spool Delrin spool Buna-N seals Operation to 50 psi Way - 5 port may be used as either single inlet - dual exhaust or dual inlet - single exhaust. Small Palm Button Large Palm Button FEATURES OPTIONS Prelubed with Magnalube G Grease terchangeability of Parts Cv =.0 56. SCFM Free Flow to Atmosphere at 80 psi Supply Operating Temperature + to +80 F; Solenoid controlled models +50 F max. See pages.7,.9 &.. OPERATING TEMPERATURE FOOTNOTE SEE PAGE. Un-anodized aluminum button with stainless steel rod in brass bushing. Standard Way spring return is normally closed. For normally open the actuators may be exchanged end for end or specify by substituting -0 for -. Force to actuate: Standard spring... 0.5 lb. Light spring (Option -L)... 9.0 lb. Double Button.... lb. Red anodized aluminum button with stainless steel rod in brass bushing. Standard Way spring return is normally closed. For normally open the actuators may be exchanged end for end or specify by substituting -0 for -. Force to actuate: Standard spring... 0.5 lb. Light spring (Option -L)... 9.0 lb. Double Button.... lb..75 Dia..09.5 Dia..0.8 Stroke.8 Stroke Light spring Specify Option -L Viton seals Specify Option -V Spools for bleeder pilot Consult factory. Note : Specify Normally Open by substituting -0 for -. Way Way Single Button - Spring Return / NPT PS- PS- / Stacking N/A MPS- /8 NPT PS- PS- Single Button - Pilot Return / NPT PSP- PSP- / Stacking N/A MPSP- /8 NPT PSP- PSP- Double Button / NPT PPS- PPS- / Stacking N/A MPPS- /8 NPT PPS- PPS- Replacement spool & seals 00-90 00-90 Way Way Single Button - Spring Return / NPT PL- PL- /8 NPT PL- PL- Single Button - Pilot Return / NPT PLP- PLP- /8 NPT PLP- PLP- Double Button / NPT PPL- PPL- /8 NPT PPL- PPL- Replacement spool & seals 00-90 00-90 Panel Mount Button Phenolic button with plated steel Way Way Spring Return rod in brass bushing; black button () 7/8 Hex x. thick brass nuts included / NPT PMS- PMS- standard, red button Option -R..8 Stroke /8 NPT PMS- PMS- Standard Way assemblies are /-6 Pilot Return / NPT PMP- PMP- normally closed with knob in the /8 NPT PMP- PMP- out position. For normally open Replacement spool & seals for above specify by substituting -0 for -. 00-90 00-90 Detented (Push Pull) Force to actuate:.8.8 / NPT PMD- PMD- Standard spring... 0.5 lb. /8 NPT PMD- PMD- Dia..8 Light spring (Option -L)... 9.0 lb. Replacement spool & seals 00-9 00-9 Detented....0 lb. cludes factory assembled spool attachments. Hand Lever Palm Button Assembly Hardened & plated steel shaft with unique connection to spool results in positive shifting. Standard Way spring return is normally closed. For normally open specify by substituting -0 for -. Force to actuate: Standard spring... 0.0 lb. Light spring... 6.0 lb. (Option -L) Detented....0 lb. Rod Actuator Assembly Dia..75 5 Lever position when spring returned. Most Threaded- Operators are terchangeable Between Ends Spring Housing Assembly Way Way Spring Return / NPT HLS- HLS- /8 NPT HLS- HLS- Detented / NPT HL- HL- /8 NPT HL- HL- Replacement spool & seals 00-9 00-9 cludes factory assembled spool attachments Pilot Bushing No. 00- Large Button No. 00- Small Button No. 00- No. 00- Light Spring only (for Option -L) No. 00-5 Standard Spring only No. 00-6 Light Spring & Housing Assembly (for Option -L). No. 00-56 Standard Spring & Housing Assembly. No. 00-8 /8 NPT Port Panel Mount Button Assembly Black button standard Red button Option -R -7-08 For Detented (with Spool) No. 00-7- ( Way Normally Closed) 00-7-0 ( Way Normally Open) Above NOT interchangeable End for End 00-7- ( Way) For Spring or Pilot Return (No Spool) 00-8 ( Way N.O. or N.C., and Way) Fabco-Air has the expertise and willingness to design. modify and adapt these valves to your necessary and specific job requirements. Please advise us of your needs..

/ & /8 NPT -Way, Position & Series / NPT & /8 NPT Ported, Manual & Pilot Operated, & Solenoid Controlled Air Valves New Spools for & Series Air Valves New 5 Ported, -Position -Way Operation 5 -Way - 5 Ported - Position - Type B Blocked Center position - All ports blocked and isolated. Use on conventional block and hold circuits. / NPT & /8 NPT Ported, Pilot Operated Air Valves 5 Ported, -Position -Way Operation 5 -Way - 5 Ported - Position - Type F Float Center position - let blocked and Cylinders open to exhaust Used to vent both ends of cylinder to allow cylinder to float with a manual or machine movement. Flow controls or exhaust speed controls should not be used. Model -DPF Shown Features Aluminum bar body Anodized black Honed and burnished bore Delrin spool, pressure balanced Buna N seals May be used as either single inlet-dual exhaust or dual inlet-single exhaust Pre-lubed with Magnalube G Grease Operating Range Operating pressure...0 to 50 psi Minimum pilot pressure... psi Cv =.0 (56. SCFM free flow to atmosphere @ 80 psi supply) Temperature...+ to 80 F For long-term, continuous operation in a range of +50 F to +80 F, the Viton seal option can provide the benefits of reliable leak-free operation and extended durability. Options Viton Seals, Specify Option V Model Number Guide: -Position, Pilot Operated Spring Centered Spool Replacement Spool Type / NPT Ports /8 NPT Ports Spool and Seals B Spool DPB DPB 00-90B F Spool DPF DPF 00-90F Valve Dimensions. Both Ends /8 NPT Pilot Port Places.5.8.0 Clearance for #0 bolt.9.75.9 Typ..5.88-6-08

/ & /8 NPT -Way, Position & Series / NPT & /8 NPT Ported, Hand Lever Operated Air Valves 5 Ported, -Position -Way Operation Model -HLF Shown Features Hardened and plated steel shaft with unique connections results in positive shifting Aluminum bar body Anodized black Honed and burnished bore Delrin spool, pressure balanced Buna N seals May be used as either single inlet-dual exhaust or dual inlet-single exhaust Pre-lubed with Magnalube G Grease Operating Range Operating pressure... 0 to 50 psi Cv =.0 (56. SCFM free flow to atmosphere @ 80 psi supply) Temperature...+ to 80 F Standard catalog models are suitable for operation in intermittent low temperatures in a range of 0 to + F. A custom aluminum spool may be substituted when longterm application temperatures are expected to be 0 to + F. These should be limited to manual actuation, not spring centered. Consider that actuation force may exceed catalog specs and that spring return models may not be reliable at these low temperatures. Please consult factory. For long-term, continuous operation in a range of +50 F to +80 F, the Viton seal option can provide the benefits of reliable leak-free operation and extended durability. Options Viton Seals, Specify Option V Model Number Guide: -Position, Hand Lever Operated Spring Centered Spool Replacement Detented Spool Replacement Spool & Seals Spool & Seals Spool Type / NPT Ports /8 NPT Ports / NPT Ports /8 NPT Ports B Spool HLSB HLSB 00-9SB HLB HLB 00-9B F Spool HLSF HLSF 00-9SF HLF HLF 00-9F Dimensions Spring Centered Spool Dimensions Detented Spool.5.0 Clearance for #0 bolt.8.9.5.0 Clearance for #0 bolt.8.9.75.75.9.88.9.00.9.75-7-08.6

/ & /8 NPT -Way, Position & Series / NPT & /8 NPT Ported, 5 Style Solenoid Controlled, Pilot Operated Air Valves 5 Ported, -Position -Way Operation Model -FFB Shown Features Aluminum bar body Anodized black Honed and burnished bore Delrin spool Buna N seals Cv =.0 (56. SCFM free flow to atmosphere @ 80 psi supply) Operation to 50 psi Operating Temperature: + F (0 C) to +0 F (0 C) ambient. + F (0 C) to +50 F (65 C) media. Pre-lubed with Magnalube G Grease Coils & Housing information see page.9. Operating Range ternal pilot supply - standard let... to 50 psi External pilot supply Option X let...0 to 50 psi Pilot Supply... to 50 psi Ordering Choose valve model number from table below and add option suffixes as required and specify voltage/hertz. Model Number Guide: -Way, -Position, Spring Centered Double Solenoid Valves Conduit Housing C Grommet Housing G Male Mini-DIN Housing F Replacement Spool & Seals Spool Type / NPT Ports /8 NPT Ports / NPT Ports /8 NPT Ports / NPT Ports /8 NPT Ports B Spool -CCB -CCB -GGB -GGB -FFB -FFB 00-90B F Spool -CCF -CCF -GGF -GGF -FFF -FFF 00-90F.7-6-08

/ & /8 NPT -Way, Position & Series Conduit Housing "C" 5 Style Solenoid Operators Standard 5 Style Operator The solenoid operator is a -way NC valve which, upon receiving an electrical signal, directs pressure to shift the main valve spool. As standard, the operator is internally supplied with air pressure from the main valve inlet..5 / NPT.0 0- Exhaust Port Housing can rotate 60 /8 NPT...75. Max..75.5 5 Style Operator with External Pilot Option X the following listed applications, as well as many others, a proper air supply may not be available from the main valve inlet. For these applications, an external pilot supply port is available (Option X). A proper air supply to this port then supplies the solenoid with air pressure for piloting the main valve spool. Dual inlet, single exhaust sufficient Pressure at main valve inlet Media at main valve inlet is other than air Extreme fast cycling Grommet Housing "G".0 0- Exhaust Port.75 Housing can rotate 60 Valve Dimensions.9.5.8.0 Clearance for #0 bolt Male Mini-DIN Housing "F".75..58..88 0- Exhaust Port.7.7. ( mm) spacing Line Terminals.5 x.0.65.57. Housing can rotate 60 Ground Terminal.5 x.0.88 6.8 8-6-0.8

/ & /8 NPT, & Way, M & Series / & /8 NPT Ported 5 STYLE Solenoid Controlled, Pilot Operated Air Valves, & Way - Position Operation to 50 psi Air Options Manual override Locking...-MO Non-Locking...-MO External pilot.... -X Light spring....-l Viton seals for media compatibility... -V Explosion proof operators.... -EP See page.0 Dual let - Single Exhaust Way See page.0, Note : Optional Flow Path. Features Black anodized aluminum bar stock body Honed and burnished bore Lightweight Delrin spool provides fast, positive, reliable response Buna N seals Operation to 50 psi Coils & housing information see page.9 Cv =.0 56. SCFM free flow to atmosphere @ 80 psi Prelubed with Magnalube -G grease Operating temperature: + F (0 C) to +0 F (0 C) ambient. + F (0 C) to +50 F (65 C) media. Standard catalog models are suitable for operation in intermittent low temperatures in a range of 0 to + F. A custom aluminum spool may be substituted when long-term application temperatures are expected to be 0 to + F. These should be limited to double solenoid actuation. Consider that actuation force may exceed catalog specs and that spring return models may not be reliable at these low temperatures. Please consult factory. SINGLE SOLENOID To Order Specify: Model Number from chart Options Volts & Hertz (See page.9) Operating Range ternal Pilot Supply (Standard) Standard Spring... to 50 psi Light Spring, Option -L...0 to 50 psi Pilot Return (0 psi Pilot)..0 to 50 psi External Pilot Supply, Option -X let Pressure...0 to 50 psi External Pilot Supply, Option -X Standard Spring... to 50 psi Light Spring, Option -L...0 to 50 psi Pilot Return (0 psi Pilot)..0 to 50 psi Plug -Way Valve for -Way Service. / NPT PORTS /8 NPT PORTS / way Way WAY / Way Way Normally Normally Stacking Normally Normally Closed Open See pg.0 Closed Open Conduit Housing CS- CS-0 CS- MCS- CS- CS-0 CS- Grommet Housing GS- GS-0 GS- MGS- GS- GS-0 GS- Male Mini-DIN Housing FS- FS-0 FS- MFS- FS- FS-0 FS- Replacement Spool & Seals 00-9 00-90 00-9 00-90 00-9 00-90 00-9 SINGLE SOLENOID - PILOT RETURN Models A pilot return can be substituted for the standard spring return. It may be used in two manners.. For a pulse signal, then pilot return.. As a constant, adjustable force, spring. Supply pilot port with a constant regulated pressure. This will act as a very constant spring against the solenoid controlled pilot signal. The pilot return should be a minimum of 0 psi below the solenoid controlled pressure. To Specify, Substitute P for S in the Model Number. (Ex: CP--0/60) Double SOLENOID To Order Specify: Model Number from chart Options Volts & Hertz (See page.9) Plug -Way Valve for -Way Service. / NPT PORTS /8 NPT PORTS.9 Operating Range ternal Pilot Supply (Standard) let...0 to 50 psi External Pilot Supply, Option -X let Pressure....0 to 50 psi Pilot Supply....0 to 50 psi / way Way Way Stacking / way Way See pg.0 Conduit Housing CC- CC- MCC- CC- CC- Grommet Housing GG- GG- MGG- GG- GG- Male Mini-DIN Housing FF- FF- MFF- FF- FF- Replacement Spool & Seals 00-9 00-9 00-90 00-9 00-9 --08

/ & /8 NPT, & Way, M & Series Standard 5 STYLE Solenoid Operator The solenoid operator is a -way NC valve which, upon receiving an electrical signal, directs a pilot pressure to shift the main valve spool. As standard, the operator is internally supplied with air pressure from the main valve inlet. Also see External Pilot Supply below. See Housing Details Page.9 See Housing Details Page.9 /8 NPT...88.75. Max. 5 STYLE Solenoid Operator with External Pilot Supply Option -X the following listed applications, as well as many others, a proper air supply may not be available from the main valve inlet. For these applications, an external pilot supply port is available (Option -X). A proper air supply to this port then supplies the solenoid with air pressure for piloting the main valve spool. Dual let - Single Exhaust Way. sufficient pressure at main valve inlet. Media, at main valve inlet, other than air. Extremely fast cycling. Option -X is NOT combinable with either Option -MO or -MO Way Way Function This Way Valve may be used for any Way, Way, Selector or Diverter service. 0.0 Dia. Clearance for #0 Screw.75.9.5.56. Way - 5 Port Standard: Single let - Port # - Dual Exhaust. 5.9.0 Dia. Clearance for #0 Bolt.75.88.09.9.78. Primary.5..56 0 Secondary Spring Return Valves End Operator Normally Closed Normally Open Note : Optional Flow Path: Dual let - Ports # & #5 - Single Exhaust. Use External Pilot Supply (Option -X). 5 Standard Spring Return 0 Spring Solenoid 0 Solenoid Spring.5.8.9.0..5.88 Primary.69 Dia. 5 Secondary 7/8 Hex..75. Dia.. 5 STYLE Solenoid Operator with This manual override is a -way NC valve that when pushed, directs pilot pressure to shift the main spool. Pressure must be present at main valve inlet for this override to function. TYPE Suffix LOCKING Push to override; -MO Turn to lock in; Turn back to release. NON-LOCKING Push to override. -MO Light Spring Return Option -L Pilot Return Option -P /8 NPT Port See Page..5.5 Pilot Bushing /8 NPT 7/8 Hex 7/8 Hex Stacking - Pressure Manifolded Versions of these 00 Series / NPT solenoid valves with different adaptor blocks can be stacked and pressure manifolded for space and money savings. The valve bodies are bolted together with through tie bolts and the pressure is manifolded with O-Ring seals between valves. let pressure can be connected to either or both ends of the stack. Due to the fact that the pressure port, on all valve bodies, is tapped on both sides, the pressure manifold can be plugged at any point within the stack. This allows you to supply the stack with two different pressures, one from each end. Versions of the Air Pilot, Rod Actuator, Roller Cam and Small Palm Button valves may be mounted in the same stack along with these solenoid valves. -8-0 To Order Specify the quantity of each model desired, the order in which they are to be assembled, and Brackets, if desired..0

/ & /8 NPT, & -Way & Series / & /8 NPT Ported 58 STYLE Solenoid Controlled, Pilot Operated Air Valves, & Way - Position Features Black anodized aluminum bar stock body Honed and burnished bore Lightweight Delrin spool provides fast, positive, reliable response Simplicity Reliability Corrosion resistant construction Buna N seals Operation to 50 psi Solenoid operator information see page. Cv =.0 56. SCFM Free flow to atmosphere @ 80 psi Prelubed with Magnalube -G grease Operating temperature: + F (0 C) to + F (50 C) ambient. + F (0 C) to + F (50 C) media. Standard catalog models are suitable for operation in intermittent low temperatures in a range of 0 to + F. A custom aluminum spool may be substituted when long-term application temperatures are expected to be 0 to + F. These should be limited to double solenoid actuation. Consider that actuation force may exceed catalog specs and that spring return models may not be reliable at these low temperatures. Please consult factory. Options External Pilot...-X External Pilot and Viton Seals... -XV Light Spring...-L Viton Seals are available in the main valve only, for media compatibility, and therefore only in conjunction with External Pilot: + F (0 C) to + F (50 C). Operating Ranges, psi # Solenoid # Solenoid 0.9 Watts.5 Watts ternal pilot supply (standard) inlet pressure Non Spring Return...0 to 0...0 to 5 Spring Return.... to 0... to 5 Light Spring Option -L...0 to 0...0 to 5 External pilot supply, Option -X inlet pressure.... 0 to 50...0 to 50 External pilot supply, Option -X pilot supply Non Spring Return...0 to 0...0 to 5 Spring Return.... to 0... to 5 Light Spring Option -L...0 to 0...0 to 5. --08

/ & /8 NPT, & -Way & Series 58 STYLE Solenoid Valve, Model Number Code F S 0 0 0/60 Series = / NPT = /8 NPT Primary Actuator F = Micro DIN G = Wire leads See page. Function = Way = Way See page. For Way service plug a Way Valve Secondary Actuator F = Micro DIN* G = Wire leads* S = Spring** P = Pilot** R = Rod** B = Small Button** L = Large Button** * See page. ** See pages. &. for details Solenoid Watts = 0.9 Watts =.5 Watts Primary Solenoid Attitude = Upright 90 to Body 5 = line with Body Primary Solenoid 0 = None = Position # = Position # = Position # = Position # Secondary Solenoid Attitude 0 = Other than Solenoid = Upright 90 to Body 5 = line with Body Solenoid Attitude # only # = Upright 90 to Body Secondary Solenoid 0 = None = Position # = Position # = Position # = Position # Volts / Hertz # Solenoid (0.9 Watts) VDC VDC # Solenoid (.5 Watts) /60 VAC 0/60 VAC VDC VDC Options -X = External Pilot -XV = External Pilot & Viton Seals -L = Light Spring Viton Seals are available in the main valve only for media compatability and therefore only in conjunction with External Pilot (+ to 80 F). Example: FS--00-0/60 / NPT Primary Actuator Solenoid with Micro DIN coil; Secondary Actuator, Spring Return Way Function.5 Watt Solenoid; Primary Solenoid Upright position with in Position #; Secondary Actuator is not a Solenoid; no on Secondary Actuator No Options 0 Volt/60 Hertz. Primary Solenoid Position Section A A.75.88 or Way Valve Body Secondary Solenoid Position Section A A Primary Actuator End Secondary Actuator End External Pilot Supply Option -X /8 NPT. See page. for Operator Details.. Max. A A See page.0 for Body Details Side View Spring Return Shown Upright Solenoid Attitude # (Solenoid centerline 90 to Valve Body centerline).88 External Pilot Supply Option -X -9-08 /8 NPT.8 Primary Solenoid Position Section B B.75.88 Primary Actuator End Secondary Actuator End See page.0 See page. for Body Details for Operator Details B. or Way Valve Body B Side View Spring Return Shown line Solenoid Attitude #5 (Solenoid centerline inline with Valve Body centerline) Secondary Solenoid Position Section B B.

8 Series: /8 NPT Ported Air Valves, A & B Series: / NPT Ported Air Valves /8 & / NPT, A, B & 8 Series, & Way; & Position Operation to 50 psi Note! Spring return & spring centered models NOT suitable for dry air service. Features Direct ported /8 NPT, / NPT and / NPT high flow: & Way - Position. Way - & Position. Aluminum bar stock body and operator blocks, black anodized. Light weight aluminum spool, hard anodized for long life. Operator blocks field interchangeable. Buna N seals. Operating temperature (0 to + 80 F); solenoid controlled models +50 F max. See pages.5 &.6. All spool seals size checked to assure reliability. Single Subbase or multiple manifolds with /8 and / NPT ports for Way - & Position see Pg.7. High flow factors, see Pg.7. Parts anodized for corrosion resistance. Aluminum end caps, anodized red, locate counterbores in body to control static squeeze on seals. Aluminum center cages, anodized gold, have lips to hold seals in place. Spool cushioned with Delrin -Urethane bumper combination that absorbs shock but does not bounce the spool. Simple construction for easy servicing. Spool Lands double tapered and polished to assure easy entry into seal. Prelubed with Magnalube -G grease. Catalog Options Spools s for Piloted and Solenoid Valves External Pilot Supply for Solenoid Valve Option -X Explosion Proof Operators, Spade Coil Connections, and other Solenoid Coil choices - see Pg.9 -. High Flow Body (see Model Charts) Service Kits or Way - Seal Kit PV-90 Way - Seal Kit PV-90 Dual let - Single Exhaust - Way: See note below Mufflers for Solenoid Exhaust SM-0, See page. Other Operator Combinations Solenoid - Pilot Return Solenoid - Push-Pull Knob See Model Charts Custom Options 0- Pilot Ports 0- Auxiliary Pressure lets Viton Seals Stacking and Manifolding to Customer requirements Specials 0 -Way or Way - Position - Type This Way Valve may be used for any Way, Way, Selector or Diverter service. When used with internally supplied Solenoid Operators, the Supply Pressure must be connected to Port #. For this same reason when a normally open Solenoid Valve is ordered the Solenoid Operator will be mounted on end 0 and the Spring on End. 5 -Way - 5 Ported - Position - Type Use on all Way - Position applications 5 -Way - 5 Ported - Position - Type B Blocked Center position - All ports blocked and isolated. Use on conventional block and hold circuits. 5 -Way - 5 Ported - Position - Type F Float Center position - let blocked and Cylinders open to exhaust. Used to vent both ends of cylinder to allow cylinder to float with a manual or machine movement. Flow controls or exhaust speed controls should not be used. Fabco-Air, c. has the expertise and willingness to design and modify these valves to your necessary and specific job requirements. Please advise us of your needs. See pages ii & iii. Note: Any of these Way Valves, except the internally supplied Solenoid Valves, (See Option -X) can be used as Dual let, Single Exhaust. Using this concept, with different pressures for force application and retraction, can effect large savings of high pressure air and its cost. The larger the cylinder or the faster the cycle, the higher the savings. 8-6-0

/8 & / NPT, A, B & 8 Series Pilot Operated When Ordering: Specify Model Number from chart. Specify Options. (See page.7 &.8 for Dimensional formation.) Operating Range: let Presure...0-50 psi Pilot Pressure: Models without Spring...0-50 psi Position Standard Service Spring...5-50 psi Position Light Service Spring (Option -L)...0-50 psi Position, Spring Centered...0-50 psi Optional s Locking Locks IN - Does not lock OUT Does not lock IN - Locks OUT Non-Locking Model Suffix -MO -MO -MO -MO Direct Ported / NPT /8 NPT / NPT High Flow Position SUBBASE OR MANIFOLD MOUNTED See pg.7 and Specify Single Pilot Way - Way 8-SP -SP B-SP NA Spring Return Way 8-SP -SP B-SP A-SP Double Pilot Way - Way 8-DP -DP B-DP N Way 8-DP -DP B-DP A-DP Position Double Pilot Way 8-DPB -DPB NA A-DPB Type B Spool Double Pilot Way 8-DPF -DPF NA A-DPF Type F Spool Hand Lever Operated When Ordering: Specify Model Number from chart. Specify Options. (See page.7 &.8 for Dimensional formation.) Operating Range:...0-50 psi Direct Ported / NPT /8 NPT / NPT High Flow SUBBASE OR MANIFOLD MOUNTED See pg.7 and Specify Position Spring Return Way - Way 8-HLS -HLS B-HLS NA Way 8-HLS -HLS B-HLS A-HLS Detented Way - Way 8-HL -HL B-HL N Way 8-HL -HL B-HL A-HL Position Spring Centered Way 8-HLSB -HLSB NA A-HLSB Type B Spool Spring Centered Way 8-HLSF -HLSF NA A-HLSF Type F Spool Detented Way 8-HLB -HLB NA A-HLB Type B Spool Detented Way 8-HLF -HLF NA A-HLF Type F Spool Push-Pull Knob Operated When Ordering: Specify Model Number from chart. Specify Options. (See page.7 &.8 for Dimensional formation.) Operating Range:...0-50 psi Standard knob color is black. For red knob add suffix -R to Model Number. 7-8-0 Position Push - Pull Way - Way 8-PO -PO B-PO NA (Natural Detent) Way 8-PO -PO B-PO A-PO Push Way - Way 8-PS -PS B-PS NA Spring Return Way 8-PS -PS B-PS A-PS Push Way - Way 8-PA -PA B-PA NA Pilot Return Way 8-PA -PA B-PA A-PA Push - Push Way - Way 8-PP -PP B-PP NA Knob Both Ends Way 8-PP -PP B-PP A-PP Position Push - Pull Spring Centered Way 8-PB -PB NA A-PB Type B Spool Push - Push Spring Centered Way 8-PPB -PPB NA A-PPB Knob Both ends Type B Spool Push - Pull Spring Centered Way 8-PF -PF NA A-PF Type F Spool Push - Push Spring Centered Way 8-PPF -PPF NA A-PPF Knob Both ends Type F Spool Direct Ported / NPT /8 NPT / NPT High Flow SUBBASE OR MANIFOLD MOUNTED See pg.7 and Specify.

/8 & / NPT, A, B & 8 Series /8 & / NPT Ported, 5 STYLE Solenoid Controlled, Pilot Operated Air Valves Way, Way - Position Way or Position Operation to 50 PSI Air See pages.7 &.8 for dimensional information. Operating Temperature: 0 F ( 8 C) to +0 F (0 C) ambient. 0 F ( 8 C) to +50 F (65 C) media. Operating Ranges, psi ternal Pilot Supply (Standard) let Pressure No Spring... 0 to 50 Spring: Position... 5 to 50 Position Light Service Spring, Option -L... 0 to 50 Position.... 0 to 50 External Pilot Supply, Option -X: let Pressure... 0 to 50 When Ordering: Pilot Pressure, Same as ternal Pilot Supply above. Specify Model Number from Chart Optional s Model Suffix Specify Options Locking -MO Specify Volts / Hertz Locks IN - Does not lock OUT -MO See pages.9 &.0 for Solenoid Operator, Does not lock IN - Locks OUT -MO Coil and Housing information. Non-Locking -MO Conduit Housing C /8 NPT / NPT /NPT High Flow Sub-base/Manifold, See Pg..7 Position Single Solenoid / Way, NC 8 CS CS B CS NA Spring Return / Way, NO 80 CS 0 CS 0B CS NA Way 8 CS CS B CS A CS Single Solenoid / Way 8 CA CA B CA NA Pilot Return Way 8 CA CA B CA A CA Single Solenoid / Way 8 CP CP B CP NA Knob Return Way 8 CP CP B CP A CP Double Solenoid / Way 8 CC CC B CC NA Way 8 CC CC B CC A CC Position Solenoid Pilot, B Spool Way 8 CAB CAB NA A CAB Solenoid Pilot, F Spool Way 8 CAF CAF NA A CAF Double Solenoid B Spool Way 8 CCB CCB NA A CCB Double Solenoid F Spool Way 8 CCF CCF NA A CCF Grommet Housing G /8 NPT / NPT /NPT High Flow Sub-base/Manifold, See Pg..7 Position Single Solenoid / Way, NC 8 GS GS B GS NA Spring Return / Way, NO 80 GS 0 GS 0B GS NA Way 8 GS GS B GS A GS Single Solenoid / Way 8 GA GA B GA NA Pilot Return Way 8 GA GA B GA A GA Single Solenoid / Way 8 GP GP B GP NA Knob Return Way 8 GP GP B GP A GP Double Solenoid / Way 8 GG GG B GG NA Way 8 GG GG B GG A GG Position Solenoid Pilot, B Spool Way 8 GAB GAB NA A GAB Solenoid Pilot, F Spool Way 8 GAF GAF NA A GAF Double Solenoid B Spool Way 8 GGB GGB NA A GGB Double Solenoid F Spool Way 8 GGF GGF NA A GGF Male Mini-DIN Housing F /8 NPT / NPT /NPT High Flow Sub-base/Manifold, See Pg..7 Single Solenoid / Way, NC 8 FS Position FS B FS NA Spring Return / Way, NO 80 FS 0 FS 0B FS NA Way 8 FS FS B FS A FS Single Solenoid / Way 8 FA FA B FA NA Pilot Return Way 8 FA FA B FA A FA Single Solenoid / Way 8 FP FP B FP NA Knob Return Way 8 FP FP B FP A FP Double Solenoid / Way 8 FF FF B FF NA Way 8 FF FF B FF A FF Position Solenoid Pilot, B Spool Way 8 FAB FAB NA A FAB Solenoid Pilot, F Spool Way 8 FAF FAF NA A FAF Double Solenoid B Spool Way 8 FFB FFB NA A FFB Double Solenoid F Spool Way 8 FFF FFF NA A FFF.5 --08

/8 & / NPT, A, B & 8 Series /8 & / NPT Ported, 58 STYLE Solenoid Controlled, Pilot Operated Air Valves Way, Way - Position Way or Position Spring Return and Spring Centered Models NOT suitable for dry air service See pages.7 &.8 for other dimensional information,. for solenoid information. Operating Temperature: 0 F ( 8 C) to + F (50 C) ambient. 0 F ( 8 C) to + F (50 C) media. Operating Ranges, psi # Solenoid # Solenoid 0.9 Watts.5 Watts ternal Pilot Supply (Standard) let Pressure No Spring:...0 to 0...0 to 5 Spring: Position...5 to 0...5 to 5 Position Light Service Spring, Option -L...0 to 0...0 to 5 Position...0 to 0...0 to 5 External Pilot Supply, Option -X: let Pressure...0 to 50...0 to 50 Pilot Pressure, Same as ternal Pilot Supply above. 58 STYLE Solenoid Valve, Model Number Code F S 5 0 0 0/60 Primary Actuator F = Micro DIN G = Wire leads See page. Secondary Actuator F = Micro DIN, Pos.* FB = Micro DIN Position Type B* FF = Micro DIN Position Type F* G = Wire leads, Pos.* GB = Wire leads Position Type B* GF = Wire leads Position Type F* S = Spring** A = Pilot** P = Knob (Black)** PR = Knob (Red)** * See page.,.. ** See pages. &.8 for details. Series: 8 = /8 NPT, Way 8 = /8 NPT, Way NC 80 = /8 NPT, Way NO = / NPT, Way = / NPT, Way NC 0 = / NPT, Way NO A = Way, Subbase Mount B = / NPT, Way, Position High Flow B = / NPT, Way NC, High Flow 0B = / NPT, Way NO, High Flow Primary Solenoid Attitude 5 = line with Body Solenoid Watts = 0.9 Watts =.5 Watts Primary Solenoid 0 = None = Position # = Position # = Position # = Position # Secondary Solenoid Attitude 0 = Other than Solenoid 5 = line with Body Secondary Solenoid 0 = None = Position # = Position # = Position # = Position # Volts / Hertz # Solenoid (0.9 Watts) VDC, VDC # Solenoid (.5 Watts) /60 VAC 0/60 VAC VDC VDC Options -X = External Pilot -XV = External Pilot & Viton Seals -L = Light Spring Viton Seals are available in the main valve only for media compatability and therefore only in conjunction with External Pilot [0 F ( 8 C) to + F (50 C)]. Example: FS-500-0/60 / NPT, Way Primary Actuator Solenoid with Micro DIN coil; Secondary Actuator, Spring Return.5 Watt; Primary Solenoid line Attitude with on Primary Solenoid in Position #; Secondary Actuator is not a Solenoid; no on Secondary Actuator No Options 0 Volt/60 Hertz. External Pilot Supply Option -X.75. /8 NPT.70.96 Primary Actuator End or Way Valve Body Secondary Actuator End line Solenoid Attitude #5 (Solenoid centerline inline with Valve Body centerline) Primary Solenoid Position Section A A See page. for Operator Details See page.7 for Body Details A Side View Secondary Solenoid Position Section A A -6-08 A Spring Return Shown.6

/8 & / NPT, A, B & 8 Series basic Bodies.75 Primary.75. 0.75 Primary..75.5 Secondary.00.5.7 Dia. Mounting Hole, Places WAY (Plug Way) WAY Spring Return Assembly Standard this End.7 Dia. Mounting Hole, Places WAY Spring Return 5 Assembly Standard this End.5 single Subbases 5.00 Secondary To Order Specify Valve Model No. (See pages. -.6) Specify Subbase Part No. listed below. EXAMPLE - Photo shows A-SP-MO with PV-50 SidE PORTEd /8 NPT Ports Specify 8 PV-50 / NPT Ports Specify PV-50 -Way -Way Position - Type Spool -Way Position - Type Spool Way Position Cv FLOW FACTORS Type B Spool Type F Spool NOTE: Any of these -way valves, except the internally supplied solenoid valves (see Option -X), can be used as dual inlet, single exhaust. Using this concept, with different pressures for force application and retraction, can effect large savings of high pressure air and its cost. The larger the cylinder or the faster the cycle, the higher the savings. Mount way valve with any operator Direct Ported /8 or / / NPT NPT High Flow. 6.. 6.. NA Subbase Mounted Side or Bottom Ported /8 NPT / NPT NA NA..7.. Shifted to ; to. NA.. Shifted to ; to 5. NA..9 Centered to ; to 5.7 NA.6.8 BOTTOM PORTEd /8 NPT Ports Specify 8 PV-5 / NPT Ports Specify PV-5 /8 or / NPT IN & EXH Ports.75 /8 or / NPT CYL Ports Secondary. 5 Basic Body line Basic Body line.8.8.88.5.88.8..75 5 /8 or / NPT IN, CYL & EXH Ports Basic Body line Secondary.8.5.5 Multiple Manifolds Primary.00. Dia. Mounting Holes Places To Order Specify Station No. - Valve Model - Manifold Number EXAMPLE - Photo shows one unit consisting of valves and manifolds: Sta. No. A-CS-MO with PV-65 Sta. No. A-DP with PV-66 Sta. No. A-HL with 8 PV-65. Dia. Mounting Holes Places.88 Mount any Combination of way valve models & Port sizes.5 Primary.00.5.6 Secondary /8 or / NPT CYL Ports on Bottom.75.5 / NPT IN & EXH Ports.7 Basic Body line 5 /-0 Tie Rods Primary.00 5.00. Dia. Mounting Holes - Each End.75.5..8 /-0 x.00.5 S.H.C. Valve.00 TYP..8 TYP. Mounting Screws.78 Station Station Station Station Etc. Valve Body & CYL Port C L Top View Cylinder Ports /8 NPT / NPT End Unit / NPT IN & EXH 8 PV-65 PV-65 Center Unit 8 PV-66 PV-66-8-08

/8 & / NPT, A, B & 8 Series.5 Air Pilot Operator Air Pilot Operator with Pilot Port.75.8 /8 NPT.85.9 Pilot Port Max. /8 NPT The 5 STYLE solenoid operator is a -way valve which, upon receiving an electrical signal, directs a pilot pressure to shift the main valve spool. Unless otherwise specified, the operator is internally supplied from the main valve inlet with pressure for piloting. If an external pilot supply is required specify Suffix -X after the model number. This external pilot supply may be required; where the media through the main valve is of insufficient pressure for piloting, where the media through the main valve is something other than compressed air, for -way dual inlet-single exhaust, or other applications..88 Min. Position, Spring return Dimensions shown at the bottom of the page. Position Spring Centering is incorporated within the operator dimensions. s applicable to Pilot Operated or 5 Style Solenoid Operated Valves Locking Locks IN - Does not lock OUT Does not lock IN - Locks OUT Non-Locking To Specify Add Suffix to Model Number -MO -MO -MO -MO Note: The manual override stem physically contacts and moves the spool. 5 style Solenoid Operator.75 See page.9 for Operator Details Housing Can Rotate 60.85 5 style Solenoid Operator with and External Pilot Supply, Opption -X Option -X /8 NPT External Pilot Supply.8 See page.9 for Operator Details.88 Min..8 Max..85 Position, Spring return Dimensions shown at the bottom of the page. Position Spring Centering is incorporated within the operator dimensions. 58 style Solenoid Operator See page.6.8 Dia. 5 5 Hand Lever Operator position spring centering Operator for hand lever only.5.06.00.75.8 Max..5-7-08.8 Dia..8 Stroke.65 Palm Button Operator Position, Spring return Dimensions shown to right. Position Spring Centering is incorporated within the operator dimensions..9.75.5 position spring return, standard & light service All valve models Standard service spring consists of two concentric helical springs. Either may be removed for Light Service..8

Directional Solenoid, Coil Control and Housing Valves formation 5 Style 5 Style Stocked Coils and Housings Conduit Housing C and Grommet Housing G Non-molded Class A F (05 C) Rating, " Leads of AWG #8 Wire. Stocked Voltages:, 0 and 0 Volt at 50 or 60 Hertz; 6, and Volt DC; Others available, see Options on page.0. Temperature Range: 0 F ( 8 C) to + 0 F (+0 C), ambient. 0 F ( 8 C) to + 50 F (+65 C), media. Typical Response Times: AC to 8 milliseconds to open or close; DC 9 to 5 milliseconds to open; DC 5 to milliseconds to close. To compute current requirements (±5%) divide factor shown below by voltage Conduit Housing C.5 / NPT.0 0- Exhaust Port Housing can rotate 60.9 AC Volts, 60 Hertz dc Volts rush, Amp Function rush, Amp Holding, Amp or Holding, Amp Way NC. Volts 7.8 Volts Way NO 5. Volts 9.0 Volts 7. Volts Way NC or NO Examples 5. 0 = 9.0 0 = 7. =. Amp.08 Amp.60 Amp Male Mini-DIN Housing F Molded Water Tight - Class A F (05 C) IP65 Coil Rating. European (DIN) Style mm spacing. See page.0 for connectors or contact your local distributor for additional choices. Can also be connected with individual.5" quick connect terminals. Stocked Voltages:, 0 and 0 Volt at 50 or 60 Hertz; and Volt DC; Others available, see Options on page.0. Temperature Range: 0 F ( 8 C) to + 0 F (+0 C), ambient. 0 F ( 8 C) to + 50 F (+65 C), media. Typical Response Times: AC to 8 milliseconds to open or close; DC 9 to 5 milliseconds to open; DC 5 to milliseconds to close. To compute current requirements (±5%) divide factor shown below by voltage. AC Volts, 60 Hertz dc Volts rush, Amp Function rush, Amp Holding, Amp or Holding, Amp Way NC. Volts 9.7 Volts 0. Volts Way NO Way NC or NO Examples 5. Volts 5. 0 =.8 Volts.8 0 = 0. Volts 0. =. Amp.0 Amp.87 Amp Grommet Housing G.88. 0- Exhaust Port.0 0- Exhaust Port.75 Housing can rotate 60 Male Mini-DIN Housing F.58.7.7 Housing can rotate 60.. ( mm) spacing.57 Line Terminals.5 x.0 Ground Terminal.5 x.0 Spade terminals accept miniature rectangular quick connect socket (Female DIN style connector, mm spacing) or individual.5" quick connect terminals. --08

Directional Solenoid, Coil Control and Housing Valves formation 5 Style 5 Style Options for Conduit Housing C and Grommet Housing G AC Voltages from 5. to 575 in 50 or 60 Hertz. DC Voltages from to 00. Molded Coil...Option -M Water tight, Molded Coil with Class A F (05 C) Rating. Coil is completely molded in epoxy for maximum moisture resistance. NEMA,, and when in Conduit C, or Grommet G housing. Potted Coil...Option -P Coil is epoxy potted into Conduit C housing only. Class F F (05C) Rating. It offers maximum moisture and vibration resistance. NEMA R, S,, X, 6,, &. High Temperature..................... Option -H Molded coil with 56 F (80 C) rating. Viton Seals (for media compatibility)...option -V Strain Relief Connector...Option -Q AN Connector...................... Option -W Splice Box.......................... Option -J Mounting Bracket..................... Option -R Third Wire Ground...Option -CC A CSA requirement. 5 Style Options for Male Mini-DIN Housing F AC Voltages from. to 77 in 50 or 60 Hertz. DC Voltages from to 80. Viton Seals (for media compatibility).............. Option -V 5 Style Options for Yoke Housing Yoke with Standard coil (" flying leads)...option -YB Yoke with Molded coil (" flying leads)...option -YM Yoke with Molded Spade Terminal and coil...option -KM Yoke replaces housing for protected and control box applications. Molded coil with two.5" spade terminals for quick assembly and disconnect..0 0- Exhaust Port.60 0- Exhaust Port.67 / NPT.5..60.5 x.0 Thick Flying Leads Coil.7 Spade Coil 5 Style Explosion Proof...Option -EP UL File #E7780 CSA File #LR-689 For hazardous locations, includes Molded Coil. UL Class I Div. Groups C & D. UL Class II Div. Groups E, F & G. UL Class II Div. Groups A, B, C, D, E & F. NEMA 7 Class Group D. NEMA 9 & 9A Class II Groups F & G.! Caution! To prevent explosion, disconnect electrical circuit before opening enclosure! Keep tightly closed when in operation...60.75 Option -EP Current Factors Housing can rotate 60 AC Volts, 60 Hertz rush... Holding Way NC 6.0... 7.8 Way NO 6.9... 0.7 Way NC or NO 6.9... 0.7 DC Volts rush or Holding Way NC or NO 7. Way NC or NO 7. Divide Factor shown above by Volts to find current. See examples on opposite page. --08.0

Directional Solenoid, Coil Control and Housing Valves formation 58 Style 58 Style Way Normally Closed Exhaust to Atmosphere Temperature Range: 0 F ( 8 C) to + F (+50 C), ambient. 0 F ( 8 C) to + F (+50 C), media. Available with or without Push Button # Operator 0.9 Watts Volts... VDC... VDC Amperage Draw (approximate)...7 ma...7 ma Response time: 9 ms @ 0 psi 0.6 mm let Orifice 0.8 mm Exhaust Orifice 0 psi Maximum Operating Pressure # Operator.5 Watts Volts See Chart at Right Amperage Draw See Chart at Right Response time: 8 ms with DC Volts; 9 ms with AC Volts..0 mm let Orifice.0 mm Exhaust Orifice 5 psi Maximum Operating Pressure Amperage Draw, ma Volts Hertz rush Holding 60 5 0 0 60 7 DC 9 9 DC 5 5 58 Style [# (0.9 Watts), or # (.5 Watts)] Operator Male Micro-DIN, Coil F Molded Water Tight Class A F (05 C ) IP65 Coil Rating European (DIN) Style 9. mm spacing See page. for connectors or contact your local distributor for additional choices. 58 Style [# (0.9 Watts), or # (.5 Watts)] Operator Wire Leads, Coil G Molded Water Tight Class A F (05 C) IP65 Coil Rating Leadwires AWG #0, 8 inches long.6.06..9.7 (9.mm) Spacing. Exhaust Port Manual override if ordered.0.7.9 Line Terminal. x.0 Exhaust Port Manual override if ordered AWG #0 8" Long.89.89.8 Dia..8 Dia...5 Ground Terminal. x.0.5 --08

Directional Solenoid Accessories Control Valves 5 & 58 Style Solenoid Exhaust Mufflers, #SM-0 for "C" & "G" housings and "F" DIN coil operators. See page.. Connectors 5 Style ( mm spacing) For Male Mini-DIN Housing F Part Number without LED:...-09-N Black Housing Part Number with LED:....-09-T-A.-Voltage Available in,, 0, or 0 Volt; AC or DC only. (Transparent Housing allows LED to be seen) Receptacle with mm spacing mates with Mini-DIN Housing F..79.00.8..7 Cable Diameter 6 Ga. Max. Wire Diameter. Housing can be rotated around receptacle, in 80 increments, to locate cable in desired attitude. M Connector Screw Profile Gasket, Nitrile Ribber Connectors 58 Style (9. mm Spacing) For Male Micro-DIN Housing F : Part Number without LED:...9-07-N Black Housing Part Number with LED:...9-07-T-A.-Voltage Available in or Volt, AC or DC only. (Transparent Housing allows LED to be seen).0.6 Max. Cable Dia. 8 Ga. Max. Wire Dia. Receptacle with 9. mm spacing mates with Micro-DIN Coil F.6.8 Flat Gasket, Nitrile Ribber M Connector Screw Housing can rotate around receptacle, in 90 increments, to locate cable in desired attitude. Hard Wired Connectors... Please see Section 6 --08 J Series - Mini-DIN and Micro-DIN hard wired connectors F Series - Mini-DIN and Micro-DIN hard wired connectors.