Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018

Similar documents
Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 3 009, 012 Design 4

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

McQuay Climate Control Singer

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

McQuay. Vertical Water Source Heat Pump. FCV, FCG & FCW 036 & 042 Vintage B. WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1)

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW Vintage B. WFAS,WFDD,WFDE,WFDL,WFDS,WFME,WFMS Design A (1)

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Thinline Vertical Fan Coil. FCVC, FCVH, FCVS FHVC, FHVH, FHVS, FHWC 02, 03, 04, 06, 08, 10, 12 Design 1

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Console Water Source Heat Pump. Replacement Parts List No Revision Q 07/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay. Self-Contained Unit Ventilator UAEQ 024, 036, 044, 054. UARQ, UERQ, UGRQ 024, 030, 040, 048 Design F (6)

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

Applied Decentralized Products Water Source Heat Pump / Rev.A HWH024D, HWH030D HWW024D, HWW030D PL

McQuay Air-Cooled Reciprocating Chiller ALR

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important

REPLACEMENT PARTS MANUAL

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

Catalog Vertical Stack Water Source Heat Pumps

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

Daikin McQuay. Vertical Unit Ventilator. UAVS, UAVV, UAVR, UAVB Design F (6) Replacement Parts List No Revision P 10/2018

Eclipse 2000 Service Parts

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990

McQuay Central Station Air Handler Medium Pressure MSL

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

REPLACEMENT PARTS MANUAL

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important

Daikin. Magnitude TM Magnetic Bearing Centrifugal Chiller. WME 0501S, 0502S, 0701S, 0702S Vintage B

REPLACEMENT PARTS MANUAL

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

REPLACEMENT PARTS MANUAL

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017

McQuay. Classroom Unit Ventilator Ceiling Mounted. UAHB, UAHF, UAHR, UAHV 07, 10, 13, 15, 20 Design F (6)

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T. Last Manufactured: Replacement Parts List No Revision J 12/2017

REPLACEMENT PARTS MANUAL

McQuay Climate Control Singer. Water Source Heat Pump. VF, VG, VP Vintage C. Last Manufactured: 1982

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

Daikin McQuay. Rooftop Heat Pump. WRWA, WRGA, WRWC, WRGC WRWD, WRGD, WRWH, WRGH Designs 1, 2. Replacement Parts List No New 03/2011

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001

McQuay. Centrifugal Chiller WPV 320A - 350A. Last Manufactured: Replacement Parts List No Revision E 12/2017

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011

McQuay Enfinity TM. Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton. Catalog

McQuay Package System MPS062E, MPS070E, MPS075E PL

REPLACEMENT PARTS MANUAL

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

Transcription:

Replacement Parts List No. 700012100 Revision V 11/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

Contents Parts List Revision History... 3-4 Nomenclature Serial Number... 5 Model Number... 6 Electrical Legend...7 Blower Fan Assembly Standard Motor, Housing & Wheel Assy Diagrams... 8 009-015 Components... 9 019-070 Components...10 ECM Motor, Housing & Wheel Assy...11 Electric Heat...12 Refrigeration Circuit Diagrams...13 009-015 Components... 14-15 019-070 Components... 16-18 Hot Gas Reheat (HGRH)...19 Desuperheater...20 Water Flow Control Valve...20 Control Box MicroTech III Controls Diagrams...21 009-015 Components...22 019-070 Components...23 Compressor Capacitors...24 MTIII Control Board Label Location...25 Field Installed Accessories... 26-30 Critical Parts List Size 009-024...CPL1 Size 030-070...CPL2 WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 2

Parts List Revision History Revision Date Description New 01/09 New A 05/09 Page 10- Ref # 360 change p/ns for ECM Blower Motors. B 05/10 Page 8- Add Ring Terminal p/n 802007936 and Fastener-Dart p/n 061461701. Page 25- Add Wire Harness Assy p/n 668995801. C 06/10 Added sizes 009, 012 & 015 to RPL. Repaginated entire document. D 06/10 Pages 22-23 Added H1-H9 Connectors. Added Edge-holder p/n 668395501. Changed sensor and code descriptions. Added footnotes 1 & 2. Page 25- Added Shutoff/Balancing Valves p/n 802026097 & p/n 802026098. Page 26- Replace page with Field Accessories doc per Dan Adams. Pump Restart Relay Kit deleted. E 09/11 Page 9- Change filter from 20 x 10 x1 to 26 x 8 x 1 for p/n 060604824. Page 11- Add wheel p/n 060628001 for unit sizes 009 and 012. Page 21- Add note includes H5 harness. Pages 20-27 Numerous changes made to tubing, field accessories & control box. Pages CPL1-2 Add Critical Parts List. F 02/12 Title Page- Delete the 1 after the unit models. Page CPL1-CPL2 Delete the 1 after the unit models. G 10/12 Title Page- Change McQuay to Daikin McQuay and add Enfinity TM. Update to CS6. Page 9- Change unit size heading from 024 030 to 036. Change filter p/n 060678125 to 060687125. Page 18- Change Coil Assy p/n 668223139 to 668223153. Page 23- Change Sensors (RAT, DAT) p/n 17201601 to 669008901. H 12/12 Page 20- Move part number/unit size header over. I 08/13 Page 12-Change Ref #M360 Std. Blower Motor p/n 688949305 to 668949305. CPL1-2- Add Std. Blower Motor p/n 668949305 sizes 042-070. J 10/13 Rebranded Daikin. Numerous changes made. Page 9- Delete Filters and add to Field Installed Accessories. Pages 11-12 Update ECM motors. Page 20- Updated Reversing Valves & Solenoid. Pages 22-23 Change LonMark p/n 668105801 to 107293070. Change BACnet p/n 668105901 to 107293070. Add I/O Exp p/n 668105702. Page 24- Update Capacitors. Pages 25-28 Updated Field Installed Accessories. CPL1- Spilit CPL into two sections- for sizes 009-024 only. Update ECM. CPL2- Continue with sizes 030-070 only. Removed Exp Valves. Update ECM. K 03/15 Delete sheet metal. Numerous changes. Combined pages to Daikin Format. Delete pgs 6-9. Page 6- Delete all sheet metal. Add footnote #1. Page 7- Change motor, add ECM nameplate to diagrams. Page 8- Change capacitor p/n 668003108 to 668300112. Update motor band & arms p/ns. Delete ECM motors & add footnote #1. Page 9- Delete 15 KW Electric Heater p/ns 668204804, 668204806, 668204808. Page 10- Update Refrigeration Circuit diagrams. Page 11- Add 115V compressor size 012 p/n 668951504 & overload 668015802. Page 13- Add Desuperheater diagram & components page. Page 14- Add Water Flow Control valve diagram & components page. Page 15- Add 75V transformers p/ns 910117810, 667715902, and 910116209. Change Ref#165 Contactor p/n 106500101 to 106500102. Change SLTS p/n 107201601 to 910121227. Delete connectors H-1 to H-9. Page 16- Add 75V transformers p/ns 910116213, 667716209, 107228901, and 107511307. Change Ref#165 Contactor p/n 073322502 to 910140339. Delete connectors H-1 to H-9. Change SLTS p/n 107201601 to 910121228, 910121230 and 91012123. Pages 18-22 Updated Field Installed Accessories- numerous changes. CPL1-2- Update 115V compr size 012 & SLTS, delete comm cards & ECM motors. L 10/15 Update to Daikin format. Pages 7-8 Move Std motor sizes to page 7 & page 8 add ECM motor table and footnote. Pages 15-17 Add MTIII Controls Label Location table and footnote. CPL1-CPL2 Update to Daikin format. Split into two pages CPL1, 009-024 & CPL2, 0301-070. Continued on next page. Daikin Applied 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330 WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 3

Parts List Revision History Continued Revision Date Description M 08/16 Page 4- (Page Added) for Parts List Revision History. Repaginate Contents.Numerous chnges. Page 6- Add Code 05=F. Add Code 15= AA. Add Code 19= SYY. Code 24= A. Page 8 -Move sizes 042-070 to page 9. Add size 015 Wheel p/n 060628001. Add new diagram. New motors added. Page 9 (Page Added) Add sizes 042-070 motor arm p/n 106390501(until 11/11), qty=3. Change sizes 042-070 motor arm p/n 91012165 (11/11 & later) qty from 3 to 4. Page 14 (Page Added) Continuation of page 13 Sizes 009-024 Refrigeration Circuit. Page 16 (Page Added) Continuation of page 15 Sizes 030-070 Refrigeration Circuit. Ref# 100 Change Reversing Valve p/n 910110426 to 910110422. CPL1- CPL2 Change motor p/ns. N 10/16 Page 14- Change expansion valve p/n 106489116 to 910193787. Change expansion valve p/n 106489119 to 668102702 (size 015) & 106489119 (size 019). Page 15- Change condenser coil p/n 067789501 to 667718501 and 067789502 to 667789502. CPL1-CPL2 Update revision date. O 01/17 Page 13- Change size 024 compressor 208/230/60/1V p/n 668172101 to 668392101. CPL1-CPL2 Update revision. P 03/17 Page 16- Change Reversing Valve size 030-048 p/n 106694111 to 106694107; Size 060-070 p/n 106694113 to 106694109; and size 060-070 p/n 910110428 to 910110424. CPL1- CPL2 Update revision. Q 05/17 Pages 19, 20, CPL1 & CPL2 Add EWT to water temp sensor p/n 107201601. R 10/17 Delete Cabinet drawings and components on page 7. Page 6- Code 03 delete Designs 2-4; Code13 delete Y= None; Code 18 delete Night Control and add Always YYY; Code 21 add Non-Fused Disconnect Switch; and Code 22 add 50VA Control Transformer. Pages 7-8 Combine all standard blower fan assy diagrams on page 8 & components on page 9. Add sheet metal footnote & Ref. No. for Cabinet/Chassis components. Page 9- Add Page for Motor Capacitors. Pages 14 & 16- Change Low Pressure Switch p/n 910117560 to 910171267. Change High Pressure Switch p/n 107225101 to 910171269. Change rev valve p/ns 910110426 to 910124938, 910110428 to 910120969, 910110422 to 910198401 & solenoid p/n 910110439 to 910198415. Page 16- Add a Drain Pan table & add SSTL p/ns 910171343, 910171344, and 910171345. Page 19- Add Toggle Disconnect Switch p/n 106616101. Page 20- Add Rotary Disconnect Switch p/n 910118577. Pages 23-28- Update Field Installed Accessories. Add 3 foot Hoses, Sensors and TStats. CPL1-2 Update revision. S 01/18 Page 20- Change Contactor p/n 910140339 to 910199934. Add Relay p/n 802005906. Page 22- Add capacitor boot p/n 910127697. CPL1-CPL2 Update revision. T 05/18 Page 18- Update MTIII Diagram 208/230V. Add Ref # 060 Exp Board p/n 668105702. Add Ref # 110 Fan Speed Selection Board p/n 910143618. Add contactor p/n 910140339 and 910199934. Page 19- Update MTIII Diagram 460V and add compressor relay location Ref# 165. Add Ref # 165 compressor relay p/n 106500102. Delete edge holder p/n 668395501. Add Ref# 110 Fan Speed Selection Board p/n 910143618. CPL1- CPL2Update revision. U 10/18 Pages All- Numerous changes to document. Page 7- Add electrical legend. Page 17- Change Reversing Valve p/n 910110424 to 910198402. Page 19- Add HGRH and Reheat Valve. Page 20- Change valve body size 009-024 p/n 107179603 to 107179601 and size 030-070 p/n 107202003 to 910231772. Add Desuperheater to page. CPL1- CPL2 Update revision. V 11/18 Page 19- Combine Reheat Valve with HGRH. Change check valve p/n 669576301 to 669006701. CPL1- CPL2 Update revision. WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 4

Nomenclature Serial Number AUB U 08 11 00386 Plant Identification Abbreviation AUB = Auburn SLP= San Luis Potosi STN= Staunton Serial Number (build sequence) Week of Manufacture U= Unit Year of Manufacture 08= 2008 09=2009 10= 2010 etc. WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 5

Nomenclature Model Number W VFC 1 030 B J Y L T 04 YY A C A YY Y Code 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 YYY YYY YYY A Y YYY Y Y Y Code 17 18 19 20 21 22 23 24 25 Code 01: Unit Type W= Water Source Heat Pump Code 02: Product Identifier VFC= R410a, Floor Mounted, Standard Range VFW= R410a, Floor Mounted, Geothermal Range Code 03: Design Series 1= Design A Code 04: Unit Size (1000 s BTUH) 009= 9000 036= 36000 012= 12000 042= 42000 015= 15000 048= 48000 019= 19000 060= 60000 024= 24000 070= 70000 030= 30000 Code 05: Controls, MicroTech III Unit Controller B= MTIII- Standalone C= MTIII w/lonworks Comm Module D= MTIII w/bacnet Comm Module F= MTIII w/bacnet Comm Module- WSHP System Code 06: Voltage A= 115/60/1 F= 208/230/60/3 E= 208/230/60/1 K= 460/60/3 J= 265/60/1 L= 575/60/3 Code 07: Cabinet Height Y= None Code 08: Return Air L= Left Hand R= Right Hand Code 09: Discharge Air T= Top Code 10: Blower Motor 01= Standard PSC 04= ECM Motor Code 11: Discharge Grille/ Cabinet Type YY= None Code 12: Construction Type A= Standard B= Standard w/2 Filter Rack C= Standard w/compressor Sound Blanket D= Std w/ Compr Sound Blanket & 2 Filter Rack E= Indoor Air Quality (IAQ) F= IAQ w/2 Filter Rack G= IAQ w/compr Sound Blanket H= IAQ w/compr Sound Blkt & 2 Filter Rack Code 13: Water to Refrigerant Heat Exchanger C= Copper Inner Tube/ Steel Outer Tube S= Cupro Nickel Inner Tube/ Steel Outer Tube Code 14: Heating Options A= 5.0KW Electric Heat B= 10.0KW Electric Heat Y= None Code 15: Dehumidification AA= Hot Gas Bypass YY= None Code 16: Piping Hand Y= None Code 17: Thermostat Control YYY= None Codes 18: Always YYY Code 19: Desuperheater DSH= Desuperheater SYY= Drain Pan, Stainless Steel YYY= None Code 20: Refrigerant A= R410a Code 21: Power Connection F= Unit Mounted Non-Fused Disconnect Switch Y= None Code 22: Cabinet Electrical 50V= 50VA Control Transformer 75V= 75VA Control Transformer YYY= None Code 23: Water Flow Control C= 2-Way Mtrzd 1/2 Iso Valve, Gen l Close-Off Press, N.C. V= 2-Way Mtrzd 1/2 Iso Valve, Gen l Close-Off Press, N.O. H= 2-Way Mtrzd 1/2 Iso Valve, High Close-Off Press, N.C. D= 2-Way Mtrzd 3/4 Iso Valve, Gen l Close-Off Press, N.C. K= 2-Way Mtrzd 3/4 Iso Valve, Gen l Close-Off Press, N.O. J= 2-Way Mtrzd 3/4 Iso Valve, High Close-Off Press, N.C. Y= None Code 24: Color A= Antique Ivory, Precoat Y= None Code 25: Outside Air Y= None Code 26: Agency Type Code 27: Packaging Code 28: Extended Warranty Code 29: Product Style (1= Style 1) WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 6

Electrical Legend Sch. Sym. C1 C2 CC CM COS DAT DCS DSHP EB2 EWT HGRH HP IOEXP ISO-NC ISO-NO Description Capacitor - Compressor Capacitor - Fan Compressor Contactor Compressor Motor Condensate Overflow Protection Sensor Discharge Air Temp. Sensor Disconnect Switch Desuperheater Pump Exp Control Board, 2- Spd Fan Control Entering Water Temperature Sensor 3-Way Valve Solenoid High Pressure Switch MTIII I/O Expansion Board Isolation Valve- Normally Closed Isolation Valve - Normally Open Sch. Sym. LED1 LED2 LP LWT MIII M1 OVL R1 RAT RV SLTS X1 Description LED Annunciator/Harness LED Annunciator/Harness Low Pressure Switch Leaving Water Temperature Sensor Microtech III Main Board Fan Motor Overload Protector - Compr. Motor Relay- Fan Motor Return Air Temp Sensor Reversing Valve Suction Line Temp Sensor Transformer- 24V WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 7

Blower Fan Assembly Standard Motor, Blower Housing Assy Diagrams 380 360 320 320 380 360 500 Sizes 009-012 Sizes 015-036 Cabinet/Chassis components 370 365 500 320 360 380 Sizes 042-070 Motor Mount WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 8

Blower Fan Assembly Standard Motor, Blower Housing Assy 009-015 Components 009 012 015 Ref. No. Part Description Part Number 115/60/1 208/230/60/1 265/60/1 115/60/1 208/230/60/1 265/60/1 208/230/60/1 265/60/1 320 Blower Housing & Wheel Assy 060699602 1 1 1 1 1 1 Blower Housing & Wheel Assy 667838701 1 1 Motor, 1/8HP until 1/15 106646504 1 1 Motor, 1/8HP 1/15 & later 910151450 1 1 Motor, 1/8HP until 5/15 106646501 1 1 Motor, 1/8HP 5/15 & later 910151448 1 1 360 Motor, 1/8HP until 5/15 106646502 1 1 Motor, 1/8HP 5/15 & later 910151449 1 1 Motor, 1/6HP until 11/14 073314501 1 Motor, 1/6HP 11/14 & later 910151451 1 Motor, 1/6HP until 11/14 073314502 1 Motor, 1/6HP 11/14 & later 910151452 1 380 Blower Wheel 060628001 1 1 1 1 1 1 Blower Wheel 802000037 1 1 N/S Ring, Inlet 060629101 1 1 1 1 1 1 Capacitor, 2 MFD, 440V until 9/16 668003112 1 1 1 1 1 1 Capacitor, 2 MFD, 440V 9/16 & later 910181941 1 1 1 1 1 1 500 Capacitor, 3 MFD, 440V until 9/16 668003104 1 1 1 1 1 1 Capacitor, 3 MFD, 440V 9/16 & later 910120049 1 1 1 1 1 1 Capacitor, 7.5 MFD, 370V until 9/16 668003118 1 1 Capacitor, 7.5 MFD, 370V 9/16 & later 910181947 1 1 N/S Capacitor Bracket 850010570 1 1 1 1 1 1 1 1 N/S Capacitor Boot 910127697 1 1 1 1 1 1 1 1 N/S Cabinet/Chassis Components 1 1 1 1 1 1 1 1 1 N/S= Not Shown on diagram. WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 9

Blower Fan Assembly Standard Motor, Blower Housing Assy 019-070 Components Ref. No. Part Description Part Number 019 024 Unit Size 030 036 042 048 060 070 320 Blower Housing & Wheel Assy 667838701 1 1 1 1 Blower Housing & Wheel Assy 668151101 1 1 1 1 360 Motor,1/6HP, 208-230V until 11/14 073314501 1 1 365 370 380 500 Motor,1/6HP, 208-230V 11/14 & later 910151451 1 1 Motor,1/6HP, 265V until 1/15 073314502 1 1 Motor,1/6HP, 265V 1/15 & later 910151452 1 1 Motor,1/7HP, 460V until 5/15 073314503 1 Motor,1/7HP, 460V 5/15 & later 910151453 1 Motor,1/2HP, 208-230V until 11/14 060704601 1 1 Motor,1/2HP, 208-230V 11/14 & later 910151454 1 1 Motor,1/2HP, 265V until 5/15 060704602 1 1 Motor,1/2HP, 265V 5/15 & later 910151455 1 1 Motor,1/2HP, 460V until 5/15 060704603 1 1 Motor,1/2HP, 460V 5/15 & later 910151456 1 1 Motor,1/2HP, 208-230V 668949301 1 1 1 1 Motor,1/2HP, 265V 668949303 1 1 1 1 Motor,1/2HP, 460V 668949302 1 1 1 1 Motor,1/2HP, 575V 668949305 1 1 1 1 Band, Motor Mount until 1/16 802009140 1 1 1 1 Band, Motor Mount 1/16 & later 910121966 1 1 1 1 Arm, Motor Mount until 8/11 106390501 3 3 3 3 Arm, Motor Mount 8/11 & later 910121965 4 4 4 4 Blower Wheel 802000037 1 1 1 1 Blower Wheel 802000125 1 1 1 1 Capacitor, 7.5 MFD, 370V 668003118 1 1 Capacitor, 7.5 MFD, 370V 910181947 1 1 Capacitor, 7.5 MFD, 440V until 9/16 668003114 1 1 1 1 Capacitor, 7.5 MFD, 440V 9/16 & later 910181942 1 1 1 1 Capacitor, 20 MFD, 370V 668003111 1 1 1 1 Capacitor, 20 MFD, 440V 910120047 1 1 1 1 N/S Capacitor Bracket 850010570 1 1 1 1 1 1 1 1 N/S Capacitor Boot 910127697 1 1 1 1 1 1 1 1 N/S Cabinet/Chassis Components 1 1 1 1 1 1 1 1 1 N/S= Not Shown on diagram. 1 Please contact Daikin with unit model and serial number for part numbers on Cabinet/Chassis components. WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 10

Blower Fan Assembly ECM Motor, Housing & Wheel Assy 332 ECM Motor Nameplate Detail 337 WARNING LABEL NP 400 ECM Motor Nameplate ECM Motor Mount Detail 370 370 365 365 Sizes 019-036 Sizes 042-070 Ref. No. Part Description Part Number 019 024 Unit Size 030 036 042 048 060 070 332 N/S Blower Housing & Wheel Assy 667838701 1 1 1 1 Blower Housing & Wheel Assy 668151101 1 1 1 1 Blower Wheel 802000037 1 1 1 1 Blower Wheel 802000125 1 1 1 1 337 Blower Support Bracket 106426301 2 2 2 2 2 2 2 2 365 370 Motor Band 802009140 1 1 1 1 Motor Band 910121966 1 1 1 1 Motor Arm 668405401 3 3 3 3 Motor Arm until 11/11 106390501 3 3 3 3 Motor Arm 11/11 & later 910121965 4 4 4 4 400 ECM & Program 1 See ECM motor nameplate. NS = Not Shown 1 The PN for the ECM motor is found on the label (see illustration above). You may also contact Daikin with the Unit Model & Serial Number to get the ECM Motor part number. WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 11

Electric Heat 600 Ref. No. Part Description Kw Part Number 019 024 Unit Size 030 036 042 048 060 070 600 Electric Heater, 208-230/60/1 5Kw 668204701 1 1 1 1 Electric Heater, 265/60/1 5Kw 668204704 1 1 1 1 Electric Heater, 208-230/60/1 10Kw 668204702 1 1 1 1 Electric Heater, 208-230/60/3 10Kw 668204703 1 1 1 1 Electric Heater, 265/60/1 10Kw 668204705 1 1 1 1 Electric Heater, 460/60/3 10Kw 668204706 1 1 1 1 Electric Heater, 208-230/60/1 10Kw 668204801 1 1 1 1 Electric Heater, 208-230/60/3 10Kw 668204803 1 1 1 1 Electric Heater, 265/60/1 10Kw 668204805 1 1 1 1 Electric Heater, 460/60/3 10Kw 668204807 1 1 1 1 WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 12

Refrigeration Circuit Diagrams 92 859 71 74 Evaporator/ TXV Detail Condenser Detail 69 Compressor 57 63 57 Reversing Valve Piping 61 58 61 TXV Bulb 137 160 136 Unit Size 009-015 Unit Size 019-070 Compressor Mounting Detail 100 See Coremax Valve Assy Detail 151A 151B 151C Coremax Valve Assy Detail WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 13

Refrigeration Circuit 009-015 Components 009 012 015 Ref. No. Part Description Part Number 115/60/1 208/230/60/1 265/60/1 115/60/1 208/230/60/1 265/60/1 208/230/60/1 265/60/1 57 Nut- Compressor Mount until 5/18 802012035 3 3 3 3 3 3 3 3 Acorn Nut- Compressor Mount 5/18 & later 910172114 3 3 3 3 3 3 3 3 58 Sleeve- Compressor Mount 668955501 3 3 3 3 3 3 3 3 61 Grommet- Compressor Mount 668955401 3 3 3 3 3 3 3 3 63 Washer- Compressor Mount 910172106 6 6 6 6 6 6 6 6 Compressor, 115/60/1V 668951401 1 Compressor, 208/230/60/1V 668951411 1 Compressor, 265/60/1V 668951412 1 69 Compressor, 115/60/1V 668951504 1 Compressor, 208/230/60/1V 668951501 1 Compressor, 265/60/1V 668951503 1 Compressor, 208/230/60/1V 668951601 1 Compressor, 265/60/1V 668951603 1 Overload- Compressor, 115/60/1V 668015802 1 Overload- Compressor, 208/230/60/1V 668015804 1 Overload- Compressor, 265/60/1V 668015805 1 N/S Overload- Compressor, 115/60/1V 668015802 1 Overload- Compressor, 208/230/60/1V 668015806 1 Overload- Compressor, 265/60/1V 668015805 1 Overload- Compressor, 208/230/60/1V 668015808 1 Overload- Compressor, 265/60/1V 668015810 1 71 Coil CO-AX Condenser, Copper 067789501 1 1 1 1 1 1 1 1 Coil CO-AX Condenser, CUNI 067789502 1 1 1 1 1 1 1 1 74 Adapter 106474901 2 2 2 2 2 2 2 2 92 Evaporator Coil Assy 668223163 1 1 1 1 1 1 Evaporator Coil Assy 668223160 1 1 Reversing Valve until 3/11 106694111 1 1 1 1 1 1 1 1 100 Reversing Valve 3/11 to 4/14 910110426 1 1 1 1 1 1 1 1 Reversing Valve 4/14 to 4/18 910124938 1 1 1 1 1 1 1 1 Reversing Valve 4/18 & later 910198409 1 1 1 1 1 1 1 1 Solenoid, Reversing Valve until 3/11 106694207 1 1 1 1 1 1 1 1 N/S Solenoid, Reversing Valve 3/11 to 11/17 910110439 1 1 1 1 1 1 1 1 Solenoid, Reversing Valve 11/17 & later 910198415 1 1 1 1 1 1 1 1 NS = Not Shown Continued on next page. WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 14

Refrigeration Circuit 009-015 Components, Continued 009 012 015 Ref. No. Part Description Part Number 115/60/1 208/230/60/1 265/60/1 115/60/1 208/230/60/1 265/60/1 208/230/60/1 265/60/1 136 137 High Pressure Switch until 7/11 106483301 1 1 1 1 1 1 1 1 High Pressure Switch 7/11 to 3/16 910117560 1 1 1 1 1 1 1 1 High Pressure Switch 3/16 & later 910171269 1 1 1 1 1 1 1 1 Low Pressure Switch (WVFW) until 2/13 910117943 1 Low Pressure Switch until 9/16 107225101 1 1 1 1 1 1 1 1 Low Pressure Switch 9/16 & later 910171267 1 1 1 1 1 1 1 1 151A Seat- Fitting 668188801 2 2 2 2 2 2 2 2 151B Core-Valve 668188701 2 2 2 2 2 2 2 2 151C Cap- Valve 668189501 2 2 2 2 2 2 2 2 160 859 N/S Fusible Plug Assy 850001662 1 1 1 1 1 1 1 1 Plug only, 283 F 106057401 1 1 1 1 1 1 1 1 Expansion Valve until 10/16 106489116 1 1 1 1 1 1 Expansion Valve 10/16 & later 910193787 1 1 1 1 1 1 Expansion Valve until 11/10 106489101 1 1 Expansion Valve 11/10 & later 668182702 1 1 Drain Pan Assy, SSTL 910171345 1 1 1 1 1 1 Drain Pan Assy, SSTL 910171345 1 1 N/S Condensate Pan, Plastic 3 106396801 1 1 1 1 1 1 Condensate Pan, Plastic 3 106396802 1 1 NS = Not Shown 3 Terminal Ring, Condensate Overflow Wire p/n 802007936 attaches using a stand off p/n 802028115. WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 15

Refrigeration Circuit 019-070 Components Ref. No. Part Description Part Number 019 024 Unit Size 030 036 042 048 060 070 57 Nut- Compr. Mounting 802012035 4 4 4 4 4 4 4 4 58 Sleeve- Compr. Mounting 060623401 4 4 4 4 4 4 4 4 61 Grommet- Compr. Mounting 4RHZ9154 4 4 4 4 4 4 4 4 69 Compressor, 208/230/60/1V 668172001 1 Compressor, 208/230/60/1V 668392101 1 Compressor, 208/230/60/1V 668405701 1 Compressor, 208/230/60/1V 668392201 1 Compressor, 208/230/60/1V 668407001 1 Compressor, 208/230/60/1V 668408001 1 Compressor, 208/230/60/1V 668407601 1 Compressor, 208/230/60/3V 910124566 1 Compressor, 208/230/60/3V 668405702 1 Compressor, 208/230/60/3V 668392202 1 Compressor, 208/230/60/3V 668407002 1 Compressor, 208/230/60/3V 668408002 1 Compressor, 208/230/60/3V 668407602 1 Compressor, 208/230/60/3V 668220001 1 Compressor, 265/60/1V 668172002 1 Compressor, 265/60/1V 668172102 1 Compressor, 265/60/1V 668405703 1 Compressor, 460/60/3V 668405704 1 Compressor, 460/60/3V 668392203 1 Compressor, 460/60/3V 668407003 1 Compressor, 460/60/3V 668408003 1 Compressor, 460/60/3V 668407604 1 Compressor, 460/60/3V 668220002 1 Compressor, 575/60/3V 668407004 1 Compressor, 575/60/3V 668408004 1 Compressor, 575/60/3V 668407605 1 Compressor, 575/60/3V 668220003 1 N/S Compressor Blanket 669280501 1 1 1 1 Compressor Blanket 669280601 1 1 1 1 NS = Not Shown Continued on next page. WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 16

Refrigeration Circuit 019-070 Components, Continued Ref. No. Part Description Part Number 019 024 Unit Size 030 036 042 048 060 070 Coil CO-AX Condenser, Copper 667718301 1 1 71 Coil CO-AX Condenser, Copper 667718501 1 1 Coil CO-AX Condenser, Copper 667718601 1 1 Coil CO-AX Condenser, Copper 667718801 1 1 Coil CO-AX Condenser, CUNI 667718302 1 1 71 Coil CO-AX Condenser, CUNI 667718502 1 1 Coil CO-AX Condenser, CUNI 667718602 1 1 Coil CO-AX Condenser, CUNI 667718802 1 1 74 Adapter 067789501 2 2 Adapter 106475001 2 2 2 2 2 2 Evaporator Coil Assy 668223160 1 1 92 Evaporator Coil Assy 668223159 1 1 Evaporator Coil Assy 668223158 1 1 Evaporator Coil Assy 668223161 1 1 Reversing Valve until 3/11 106694113 1 1 Reversing Valve 3/11 to 7/14 910110428 1 1 Reversing Valve 7/14 & later 910120969 1 1 Reversing Valve until 3/11 106694107 1 1 1 1 100 Reversing Valve 3/11 to 11/17 910110422 1 1 1 1 Reversing Valve 11/17 & later 910198401 1 1 1 1 Reversing Valve until 3/11 106694109 1 1 Reversing Valve 3/11 to 8/18 910110424 1 1 Reversing Valve 8/18 & later 910198402 1 1 Solenoid, RV until 3/11 106694207 1 1 1 1 1 1 1 1 N/S Solenoid, RV 3/11 to 11/17 910110439 1 1 1 1 1 1 1 1 Solenoid, RV 11/17 & later 910198415 1 1 1 1 1 1 1 1 High Pressure Switch until 7/11 106483301 1 1 1 1 1 1 1 1 136 High Pressure Switch 7/11 to 3/16 910117560 1 1 1 1 1 1 1 1 High Pressure Switch 3/16 & later 910171269 1 1 1 1 1 1 1 1 137 Low Pressure Switch until 9/17 107225101 1 1 1 1 1 1 1 1 Low Pressure Switch 9/17 & later 910171267 1 1 1 1 1 1 1 1 151A Seat- Fitting 668188801 2 2 2 2 2 2 2 2 151B Core-Valve 668188701 2 2 2 2 2 2 2 2 151C Cap- Valve 668189501 2 2 2 2 2 2 2 2 NS = Not Shown WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 17

Refrigeration Circuit 019-070 Components, Continued Ref. No. Part Description Part Number 019 024 Unit Size 030 036 042 048 060 070 160 859 N/S Fusible Plug Assy 850001662 1 1 1 1 1 1 1 1 Plug only, 283 F 106057401 1 1 1 1 1 1 1 1 Expansion Valve 106489119 1 Expansion Valve 106489112 1 1 Expansion Valve 106489111 1 Expansion Valve 106489120 1 Expansion Valve 106489121 1 Expansion Valve 106489122 1 Expansion Valve 106489123 1 Drain Pan Assy, SSTL 910171343 1 1 1 1 Drain Pan Assy, SSTL 910171344 1 1 1 1 N/S Condensate Pan, Plastic 3 106396802 1 1 1 1 Condensate Pan, Plastic 3 106396804 1 1 1 1 NS = Not Shown 3 Terminal Ring, Condensate Overflow Wire p/n 802007936 attaches using a stand off p/n 802028115. WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 18

Hot Gas Reheat (HGRH) 525 520 140 100 Ref. No. 100 Part Description 019, 024 030, 036 042, 048 060, 070 Reheat Coil Assy until 3/10 Reheat Coil Assy 3/10 to 4/11 Reheat Coil Assy 4/11 & later LH 669287018 669287014 669287017 669287015 RH 669287018 669287013 669287016 669287015 LH 669287020 669287021 669287024 669287022 RH 669287020 669287021 669287023 669287022 LH 669287028 669287026 669287027 669287029 RH 669287028 669287026 669287030 669287029 140 Check Valve 669006701 669006701 669006701 669006701 520 3-4 Way Heat Reclaim Valve 669006401 669006401 669006401 669006401 525 Solenoid Valve 669006801 669006801 669006801 669006801 WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 19

Desuperheater 110 050 Ref. No. 050 110 Part Description Unit Size Part Number Circulation Pump, 115/60/1 019-070 668200902 Circulation Pump, 208-230/60/1 019-070 668200901 Desuperheater Coil, Copper 019-070 668169101 Desuperheater Coil, Cupronickel 019-070 668169102 Water Flow Control Valve 120 115 ISO Ref. No. 115 120 Part Description Unit Size Part Number Actuator Motor, High Close-Off, NC 009-070 107179807 Actuator Motor, Std Close-Off, NO 009-070 107179808 Actuator Motor, Std Close-Off, NC 009-070 107179809 2-Way Valve Body, 1/2 until 10/17 009-024 107179603 2-Way Valve Body, 1/2 10/17 & later 009-024 107179601 2-Way Valve Body, 3/4 until 3/18 030-070 107202003 2-Way Valve Body, 3/4 3/18 & later 030-070 910231772 WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 20

Control Box MicroTech III Controls Diagrams Sizes 009-015 208/230V Shown 160 120 220 X1 MCB 40 180 IOXP 60 Sizes 019-070 460V Shown 120 220 EB1 80 MCB IOXP 40 60 Comm Card 180 160 See Contactor Detail 165 Contactor Detail Alternate WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 21

Ref. No. Description Control Box MicroTech III Controls 009-015 Components Part Number N/S= Not shown on diagram. * When ordering this board, please provide the software part number printed on the board s label. See control board photo for label location (on the page after Compresssor Capacitor). Unit Size 009 012 015 40 Main Controller, MicroTech III 668105601* 1 1 1 60 I/O Expansion Board Assy 668105702* 1 1 1 N/S Fan Speed Selection Board 910143618 1 1 1 N/S Annunciator Assy LED1 668395201 1 1 1 120 Terminal Board 802007090 1 1 1 N/S Standoff, PC Board 802028115 8 8 8 160 Contactor- Compr, 2P until 12/17 910140339 1 1 1 Contactor- Compr, 2P 12/17& later 910199934 1 1 1 N/S Relay, SPDT 056992205 1 1 1 N/S 180 220 Relay, Compr, DPST- 30A until 3/13 106500101 1 1 1 Relay, Compr, DPST- 30A 3/13 & later 106500102 1 1 1 Relay, 3PDT until 10/11 056992201 1 1 1 Relay, 3PDT 10/11 & later 802005906 1 1 1 Transformer, 50VA- 115V until 3/11 060630802 1 1 Transformer, 50VA- 115V 3/11 & later 910116204 1 1 Transformer, 50VA- 208/230V until 3/11 060614102 1 1 1 Transformer, 50VA- 08/230V 3/11 & later 910116202 1 1 1 Transformer, 50VA- 265V until 3/11 060630702 Transformer, 50VA- 265V 3/11 & later 910116203 Transformer, 75VA-115V 910117810 1 1 Transformer, 75VA- 208/230V 910116213 1 1 1 Transformer, 75VA- 265V 910116209 1 1 1 N/S Disconnect Switch- Toggle 106616101 1 1 1 N/S Line Temp Sensor (SLT) until 2/12 107201601 1 1 1 Line Temp Sensor (SLT) 2/12 & later 910121227 1 1 1 N/S Air Temp Sensor (DAT, RAT) 669008901 1 1 1 N/S Water Temp Sensor (EWT, LWT) 107201601 1 1 1 WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 22

Control Box MicroTech III Controls 019-070 Components Ref. No. Description Part Number 019 024 Unit Size 030 036 042 048 060 070 N/S Compressor Capacitor- See next page. 40 Main Controller, MicroTech III 668105601* 1 1 1 1 1 1 1 1 60 I/O Expansion Board Assy 668105702* 1 1 1 1 1 1 1 1 80 Fan Speed Selection Board 910143618 1 1 1 1 1 1 1 1 N/S Annunciator Assy LED1 668395201 1 1 1 1 1 1 1 1 Annunciator Assy LED2 668395201 1 1 1 1 1 1 1 1 120 Terminal Board 802007090 1 1 1 1 1 1 1 1 N/S Standoff, PC Board 802028115 8 8 8 8 8 8 8 8 160 Contactor- Compr, 2P until 3/13 073322502 1 1 1 1 1 1 1 1 Contactor- Compr, 2P 3/13 to 12/17 910140339 1 1 1 1 1 1 1 1 Contactor- Compr, 2P 12/17& later 910199934 1 1 1 1 1 1 1 1 N/S Relay, SPDT 056992205 1 1 1 1 1 1 1 1 165 180 220 Relay, DPST- 30A until 3/13 106500101 1 1 1 1 1 1 1 1 Relay, DPST- 30A 3/13 & later 106500102 1 1 1 1 1 1 1 1 Relay, 3PDT until 10/11 056992201 1 1 1 1 1 1 1 1 Relay, 3PDT 10/11 & later 802005906 1 1 1 1 1 1 1 1 Transformer, 50VA- 208/230V until 3/11 060614102 1 1 1 1 1 1 1 1 Transformer, 50VA- 08/230V 3/11 & later 910116202 1 1 1 1 1 1 1 1 Transformer, 50VA- 265V until 3/11 060630702 1 1 1 Transformer, 50VA- 265V 3/11 & later 910116203 1 1 1 Transformer, 50VA- 380V until 3/11 107228901 1 1 1 Transformer, 50VA- 380V 3/11 & later 910116216 1 1 1 Transformer, 50VA- 460V until 3/11 060676002 1 1 1 1 1 Transformer, 50VA- 460V 3/11 & later 910116205 1 1 1 1 1 Transformer, 50VA- 575V 056340705 1 1 1 1 Transformer, 75VA- 208/230V 910116213 1 1 1 1 1 1 1 1 Transformer, 75VA- 265V 910116209 1 1 1 Transformer, 75VA- 380V 107228901 1 1 1 Transformer, 75VA- 460V 910116209 1 1 1 1 1 Transformer, 75VA- 575V 107511307 1 1 1 1 N/S Disconnect Switch- Rotary 9110118577 1 1 1 1 1 1 1 1 N/S Line Temp Sensor (SLT) until 2/12 107201601 1 1 1 1 1 1 1 1 Line Temp Sensor (SLT) 2/12 & later 910121230 1 1 Line Temp Sensor (SLT) 2/12 & later 910121228 1 1 1 1 Line Temp Sensor (SLT) 2/12 & later 910121231 1 1 N/S Air Temp Sensor (DAT, RAT) 669008901 1 1 1 1 1 1 1 1 N/S Water Temp Sensor (EWT, LWT) 107201601 1 1 1 1 1 1 1 1 N/S= Not shown on diagram. * When ordering this board, please provide the software part number printed on the board s label. See control board photo for label location (on the page after Compresssor Capacitor). WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 23

Control Box MicroTech III Controls Components Compressor Capacitors 150 100 Ref. No. Part Description Part Number Unit Size 009 012 015 019 024 030 036 042 048 060 070 100 Capacitor Bracket 850010570 1 1 1 1 1 1 1 1 1 1 150 Compressor Capacitor- 208/230V Capacitor, 55MFD 370V until 3/12 067291522 1 1 Capacitor, 55MFD 440V 3/12 & later 910120054 1 1 Capacitor, 25MFD 370V until 3/12 669450001 1 Capacitor, 25MFD 440V 3/12 & later 910120048 1 Capacitor, 30MFD 370V until 3/12 067291518 1 Capacitor, 30MFD 440V 3/12 & later 910120049 1 Capacitor, 35MFD 370V until 3/12 067291516 1 Capacitor, 35MFD 440V 3/12 & later 910120050 1 Capacitor, 30MFD 370V until 3/12 067291518 1 Capacitor, 30MFD 440V 3/12 & later 910120049 1 Capacitor, 35MFD 370V until 3/12 067291516 1 Capacitor, 35MFD 440V 3/12 & later 910120050 1 Capacitor, 40MFD 370V until 4/12 802007850 1 Capacitor, 40MFD 440V 4/12 & later 910120051 1 Capacitor, 45FD 370V until 4/12 067291523 1 1 Capacitor, 45MFD 440V 4/12 & later 910120052 1 1 Capacitor, 70MFD 370V until 3/12 067291536 1 Capacitor, 70MFD 440V 3/12 & later 910120057 1 Capacitor, 80MFD 370V until 4/12 067291528 1 Capacitor, 80MFD 440V 4/12 & later 910120058 1 Compressor Capacitor- 265V Capacitor, 35MFD 370V until 4/12 067291516 1 Capacitor, 35MFD 440V 4/12 & later 910120050 1 Capacitor, 40MFD 370V until 4/12 802007850 1 1 Capacitor, 40MFD 440V 4/12 & later 910120051 1 1 NOTE: Compressor Capacitor not required for 3 phase units. WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 24

Control Box MicroTech III Controls MTIII Control Board Label Locations Label Label 668105702 668105901 Label Label 668105601 668105801 NOTE: When ordering the control board, please provide the software part number printed on the board s label. See above for label locations. WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 25

Field Installed Accessories Filters and Filter Racks Description 009, 012 015-024 030, 036 042, 048 060, 070 1 Filter, Throwaway 12- Pack 106535004 060604826 060604827 060604808 060604828 2 Filter, Throwaway 12- Pack 060687119 060687119 060687124 060687109 060687125 2 Filter, Merv 8 Pleated 12- Pack 669575201 669575203 669575202 669575205 669575204 2" Filter Rack LH 668987901 668987907 668987908 668987909 668987910 RH 668987902 668987903 668987904 668987905 668987906 2" Filter Rack, Painted LH 668987919 668987911 668987912 668987913 668987914 RH 668987920 668987915 668987916 668987917 668987918 * Kit includes comm module card, sensors, mounting tabs, and IM. MicroTech III Communication Modules Description Part Number BacNet Comm Module* 107293071 LonWorks Comm Module* 107293070 MicroTech III Motorized Valve Harness Description Part Number MicroTech III, H-8 Output Wire Harness Assy Kit * 910107989 * For use to integrate a field-supplied motorized valve with MTIII. Manual Valves Description 009-024 030-070 Combination Shutoff/Balancing Valve with Memory Stop (2/unit) 802026097 802026098 Ball Valve- Box of 10 106065110 106065210 Ball Valve- Box of 2 106065102 106065202 * Refer to IM 1151 for installing a motorized valve kit on MicroTech III units. Motorized Valves Description Kit * Actuator Body 2-Way Valve Kit, Motorized, NC, 1/2", CLS Off Press. 668996001 107179801 107179601 2-Way Valve Kit, Motorized, NO, 1/2", CLS Off Press. 668996002 107179810 107210401 2-Way Valve Kit, Motorized, NC, 1/2", High CLS Off Press. 668996003 107179807 107210401 2-Way Valve, Motorized, NC, 3/4, CLS Off Press. 668996004 107179801 106196601 2-Way Valve, Motorized, NO, 3/4, CLS Off Press. 668996005 107179810 106196601 2-Way Valve, Motorized, NC, 3/4", High CLS Off Press. 668996006 107179807 106196601 WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 26

Description 1 For use with 910121754, 910152147, 910152149, or 910121753. 2 For use with 910116771, 910116772, 910116773, and 910116774. Field Installed Accessories Continued Thermostats & Sensors Part Number 5.25 X 7 Adapter Plate for Sensors 1 910193064 3.75 X 5.5 Adapter Plate for Sensors 1 910201987 5.3 X 5.3 Adapter Plate for Sensors 1 910201988 Basic Room Sensor w/nsb, Override and Status LED 910152149 Room Sensor, Digital Adj, 4-Button w/ Override, Occupancy Switch & Temp Display 910152147 Room Sensor w/cool/warm Temp Adj. & Occupancy Switch 910171464 Room Sensor, Digitally Adj, Temp & Humidity Display 910121754 Wall Sensor, Adj. Cool/Warm, Occupancy Switch 910121753 Remote Sensor for use with thermostats 668375301 & 668375401 667720401 Remote Sensor for use with thermostats 910121746 & 910121748 107096010 Wall Stat: AC/DC, ACO, 7-day Programmable, 2 Heat/2 Cool with Wall Plate 668375301 Wall Stat: AC/DC, ACO, Non- Programmable, 2 Heat/2 Cool, NSB & OR with Wall Plate 668375401 Remote Sensor for Thermostat 668375301, 668375401 667720401 Remote Sensor for Thermostat 910121746, 910121748 107096010 Wall Stat: Non- Programmable, 2 Heat/2 Cool, ACO, Hardwired 910121746 Wall Stat: 7-day Programmable, 2 Heat/2 Cool, ACO, Hardwired 910121748 Programmable/Non-Programmable TStat- 2 Heat/2 Cool, ACO, Touchscreen 910193126 Programmable/Non-Programmable TStat- 2 Heat/2 Cool, ACO, Touchscreen, WIFI 910193131 Remote Sensor & Thermostat, 2-Stage, ACO/MCO, Programmable & Digital Display 910116773 RCN Kit for use with Wireless Thermostat 910105604 Trim Ring for sensors 1 910193063 Wall Plate, Insulated 2 910116770 TStat Guards Description Part Number TStat Guard 105571101 TStat Guard (10 Pack ) 105571110 Relays Description Part Number Pump Restart Relay Kit 061419001 MicroTech III to MarkIV Daisy Chain Adaption for E & U 910151282 WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 27

Description Hoses 009-024 Specification Part Number 2 Foot 3 Foot Hose Assy, Fire Rated Condensate 3/4 106063801 106063901 Hose Assy, Fire Rated Condensate Supply/Return, Plastic 3/4 X 30 106063701 N/A Hose Assy, Fire Rated Condensate Supply/Return, Plastic 3/4 N/A 106665101 Auto Flow Supply & Return w/ball Valve and Auto Flow Control Valve Kit, Fire Rated Supply/Return- 1/2. Includes: Supply Ball Valve, and 24 SSTL Hose. Return Flow Controller, Ball Valve, (2) P/T, 24 SSTL Hose. Auto Flow Supply & Return w/ball Valve, "Y" Strainer & Blowdown Valve Flow Control Hose Kit, Fire Rated Supply/Return- 1/2 Includes: Supply Ball Valve, Y-Strainer, and 24 SSTL Hose. Return Flow Controller, Ball Valve, (2) P/T, 24 SSTL Hose. 1.5 GPM 669482303 N/A 2.0 GPM 669482304 N/A 2.5 GPM 669482305 N/A 3.0 GPM 669482306 N/A 3.5 GPM 669482307 N/A 4.0 GPM 669482308 N/A 4.5 GPM 669482309 N/A 5.0 GPM 669482310 N/A 5.5 GPM 669482311 N/A 6.0 GPM 669482312 N/A 1.5 GPM 106582903 910186312 2.0 GPM 106582904 910186313 2.5 GPM 106582905 910160444 3.0 GPM 106582906 910157026 3.5 GPM 106582907 910186314 4.0 GPM 106582908 910160445 4.5 GPM 106582909 910186430 5.0 GPM 106582910 910160446 5.5 GPM 106582912 910186315 6.0 GPM 106582913 910186431 Hose Kits Supply & Return, 1/2 106062801 106063101 Hose Kits Supply & Return w/shut-off Ball Valve, 1/2" 669483401 669481302 Hose Kits S&R w/ball Valve, "Y" Strainer & Blowdown Valve, 1/2" 669481801 669481802 N/A= Not Applicable. Field Installed Accessories Continued WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 28

Description Field Installed Accessories Continued Hoses 030-070 Specification Part Number 2 Foot 3 Foot Hose Kit, Fire Rated Condensate 3/4 106063801 106063901 Hose Kit, Plastic Condensate 3/4 106063701 106665101 Hose Assy, Fire Rated Condensate Supply/Return, Plastic 3/4 X 30 106063701 N/A Hose Assy, Fire Rated Condensate Supply/Return, Plastic 3/4 N/A 106665101 Auto Flow Supply & Return w/ball Valve Flow Control Hose Kit, Fire Rated Supply/Return- 3/4. Includes: Supply Ball Valve, and 24 SSTL Hose. Return Flow Controller, Ball Valve, (2) P/T, 24 SSTL Hose. Auto Flow Supply & Return w/ball Valve, "Y" Strainer & Blowdown Valve Flow Control Hose Kit, Fire Rated Supply/Return- 3/4 Includes: Supply Ball Valve, Y-Strainer, and 24 SSTL Hose. Return Flow Controller, Ball Valve, (2) P/T, 24 SSTL Hose. 5.0 GPM 669482405 N/A 5.5 GPM 669482406 N/A 6.0 GPM 669482407 N/A 6.5 GPM 669482408 N/A 7.0 GPM 669482409 N/A 7.5 GPM 669482410 N/A 8.0 GPM 669482411 N/A 9.0 GPM 669482412 N/A 10.0 GPM 669482413 N/A 11.0 GPM 669482414 N/A 12.0 GPM 669482415 N/A 13.0 GPM 669482416 N/A 15.0 GPM 669482417 N/A 5.0 GPM 106582917 910182844 5.5 GPM 106582918 910186318 6.0 GPM 106582919 910157029 6.5 GPM 106582920 910186319 7.0 GPM 106582921 910157030 7.5 GPM 106582922 910186433 8.0 GPM 106582923 910182845 9.0 GPM 106582924 910160448 10.0 GPM 106582925 910186434 11.0 GPM 106582926 910186436 12.0 GPM 106582927 910186439 13.0 GPM 106582928 910160450 15.0 GPM 106582929 910186322 Hose Kits Supply & Return w/shut-off Ball Valve, 3/4" 669483501 669481402 Hose Kits S&R w/ball Valve, "Y" Strainer & Blowdown Valve, 3/4" 669481901 669481902 Hose Assy, Fire Rated Condensate Supply/Return, 3/4 106063801 106063901 N/A= Not Applicable. WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 29

Part Number Kit Field Installed Accessories Continued MicroTech III Temperature Sensors Tennant Override Setpoint Adjustment Status LED Note: Can only be used in conjunction with a communication (Comm.) card. See OM 931 for required jumper settings. Fan & Mode Switch 669088101 669529001 Yes No No No 668900801 669529101 Yes 55 to 95 F (12 to 35 C) Yes Yes 669088201 669529201 Yes -3 to +3 F (-1.5 to 1.5 C) No Yes Microtech III Unit Control Accessories Description ** Multiple Unit Control Panel: Allows a master unit controlled by a single thermostat, to operate up to 3 secondary units. Not Recommended for use with a Boilerless System Kit. Part Number 056794201 Boilerless System Kit with I/O Expansion Board * 910110355 Boilerless System Kit without I/O Expansion Board 910110353 * IM 1084-2 is included in Kit. ** Kit components listed below. Multiple Unit Control Panel Kit 310 311 313 Ref. No. Description Part Number Qty. 310 Cover, Control Box 106436101 1 311 Circuit Board 056794001 1 312 Stand Off, Circuit Board 802028090 6 313 Box 850007827 1 312 WSHP; WVFC1,WVFW1 009-070 Design 1 Rev. V 11/18 RPL 7000121 / Page 30

Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! Daikin Enfinity Vertical WSHP McQuay Enfinity Vertical WSHP WVFC, WVFW 009-024, Design 1 Critical Components Unit Sizes Voltage Part Number Control Control Board, MicroTech III ALL ALL 668105601 Compressor Compressor 009 115/60/1 668951401 Compressor 009 208-230/60/1 668951411 Compressor 009 265/60/1 668951412 Compressor 012 115/60/1 668951504 Compressor 012 208-230/60/1 668951501 Compressor 012 265/60/1 668951503 Compressor 015 208-230/60/1 668951601 Compressor 015 265/60/1 668951603 Compressor 019 208-230/60/1 668172001 Compressor 019 265/60/1 668172002 Compressor 024 208-230/60/1 668392101 Compressor 024 265/60/1 668392102 Blower Motor Standard Motor, 1/8HP 009, 012 115/60/1 910151450 Standard Motor, 1/8HP 009, 012 208-230/60/1 910151448 Standard Motor, 1/8HP 009, 012 265/60/1 910151449 Standard Motor, 1/6HP 015-024 208-230/60/1 910151451 Standard Motor, 1/6HP 015-024 265/60/1 910151452 Standard Motor, 1/6HP 015-024 460/60/3 910151453 ECM & Program ALL ALL See motor nameplate Blower Housing and Wheel Blower Housing Assy 009, 012 N/A 060699602 Blower Housing Assy 015-024 N/A 667838701 Wheel, Blower 009-015 N/A 060628001 Sensor Line Temp Sensor (SLTS) 009-015 N/A 910121227 Line Temp Sensor (SLTS) 019, 024 N/A 910121230 Air Temp Sensor (DAT, RAT) ALL N/A 669008901 Water Temp Sensor (EWT, LWT) ALL N/A 107201601 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call 1-800-37PARTS 7000121 Rev. V 11/2018 CPL Page 1 of 2

Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! Daikin Enfinity Vertical WSHP McQuay Enfinity Vertical WSHP WVFC, WVFW 030-070, Design 1 Critical Components Unit Sizes Voltage Part Number Control Control Board, MicroTech III ALL ALL 668105601 Compressor Compressor 030 208-230/60/1 668405701 Compressor 030 208-230/60/3 668405702 Compressor 030 265/60/1 668405703 Compressor 030 460/60/4 668405704 Compressor 036 208-230/60/1 668392201 Compressor 036 208-230/60/3 668392202 Compressor 036 460/60/3 668392203 Compressor 042 208-230/60/1 668407001 Compressor 042 208-230/60/3 668407002 Compressor 042 460/60/3 668407003 Compressor 042 575/60/3 668407004 Compressor 048 208-230/60/1 668408001 Compressor 048 208-230/60/3 668408002 Compressor 048 460/60/3 668408003 Compressor 048 575/60/3 668408004 Compressor 060 208-230/60/1 668407601 Compressor 060 208-230/60/3 668407602 Compressor 060 460/60/3 668407604 Compressor 060 575/60/3 668407605 Compressor 070 208-230/60/3 668220001 Compressor 070 460/60/3 668220002 Compressor 070 575/60/3 668220003 Blower Motor Standard Motor, 1/2HP 030-036 208-230/60/1 910151454 Standard Motor, 1/2HP 030-036 265/60/1 910151455 Standard Motor, 1/2HP 030-036 460/60/3 910151456 Standard Motor, 1/2HP 042-070 208-230/60/1 668949301 Standard Motor, 1/2HP 042-070 265/60/1 668949303 Standard Motor, 1/2HP 042-070 460/60/1 668949302 Standard Motor, 1/2HP 042-070 575/60/1 668949305 ECM & Program ALL ALL See motor nameplate Blower Housing and Wheel Blower Housing Assy 030, 036 N/A 667838701 Blower Housing Assy 042-070 N/A 668151101 Sensor Suction Line Temp Sensor (SLTS) 030-048 N/A 910121228 Suction Line Temp Sensor (SLTS) 060, 070 N/A 910121231 Air Temp Sensor (DAT, RAT) ALL N/A 669008901 Water Temp Sensor (EWT, LWT) ALL N/A 107201601 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call 1-800-37PARTS 7000121 Rev. V 11/2018 CPL Page 2 of 2