Sun Sensor setting in PumpScanner Daily output in average month 52 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Similar documents
Water temperature: Dirt loss: Total dynamic head:

SunSwitch setting in PumpScanner. Daily output in average month 219 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Daily output in April 193 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Daily output in average month 77 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Daily output in May 32 m³

SunSwitch setting requirements min. 15 % Daily output in average month 154 m³

DIN W.-Nr AISI 304

Company name: Created by: Phone:

4HS MultiPower Submersible Pumps. Installation and Operating Manual. M u l t i P o w e r. man4hs_mp_11_eng

4TCH Submersible Pumps. Installation and Operating Manual

4HS MultiPower Submersible Pumps. Installation and Operating Manual.

Yield Reduction Due to Shading:

AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X-3640-LED-185-T

Yield Reduction Due to Shading:

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

Station Identification. Results. PV System Specifications. Energy Specifications. Solar Radiation (kwh/m 2 /day) Energy Value ($) AC Energy (kwh)

P H O T O V O LTA I C

NEW-TEK SCHMID R Company High-tech enterprise for the production of PV solar modules

INDEX. 3 BOREHOLE DC SOLAR PUMPS 3LLS...4 PERIPHERAL VANE DC SOLAR PUMP 3LSQB2...6

Energy Produced by PV Array (AC):

250 Watt. Features. Positive tolerance Positive tolerance of up to 5% delivers higher outputs reliablity

Solar water pumping- Cheaper, Cleaner, Sustainable. Improving People s lives

Energy & Cost Savings The Friends Meeting of Austin 3701 Martin Luther King Blvd. Austin, TX (46) Sharp 208 W Modules = 9.

18.6% 0-5w. Years. Grid. Certification. BYD PV Module 25 Years Linear Performance Warranty

Warranty on production defects: 12 years WP YEARS WARRANTY. CLASS 1 CLASS 1 Reaction to fire according to the UNI 9177 UNI standard IEC 61215

Manual for Installation and Operation

X-SERIES SOLAR PANELS

Product Manual. Installation Instructions for CHSM-230M Series Solar Module

Example printout. Building project. SDC Example. Dyfi Eco Park SY20 8AX Machynlleth UK. Mr C. Laughton Phone:


Results of annual simulation

KIT SOLAR MONTE PERDIDO

RNG Mono. Monocrystalline Type 10/20/30/50/60/100/150/250W. Key Features High module conversion efficiency. Application. Linear Warranty.

AC MODULE P72PCS-300W

IDCOL Technical Standard for Solar Irrigation Pump (SIP) Under TR/KABITA Program

Photovoltaic Modules Installation Manual for Australia

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

Todae Solar s 1.22 MWp Rooftop Solar Photovoltaic Installation for Stockland Shellharbour, NSW.

Conergy PH 185M 200M. Special Edition Australia. Specifications Photovoltaic modules

Wind Energy System.

PV Module Installation Manual

IDCOL Technical Standard for Solar Irrigation Pump (SIP) Under Ownership Model

4 submersible pumps powered by renewable energy sources

Product Catalogue. Europe

Naresuan University, Phitsanulok 65000, Thailand *Corresponding author ABSTRACT

GRUNDFOS DATA BOOKLET. Grundfos RSI. Renewable solar inverter for pump control kw

User Manual Version: 1.4

E-SERIES RESIDENTIAL SOLAR PANELS

4 submersible pumps with integrated electronics powered by renewable energy sources ENGLISH

IEC INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL FOR CRYSTALLINE SOLAR PV MODULE

TSM-DC01A. The Solution NEW. linear performance warranty. Module can bear snow loads up to 5400Pa and wind loads up to 2400Pa

2012 DFW Solar Home Tour October 6, 2012 Reference Solar PV

Master Class on PVsyst Solar Project Designing Tool 7 th June 2013

PM300P00 Installation Guide for Users

SOLAR ENERGY KIT MODEL: SISMA-CT20000

PM220P00 / PM240P00 Installation Guide for Users

INSTALLATION & OPERATION MANUAL

SAMPLE PERMIT APPLICATION PACKAGE

KIT-STCS60D KIT-STCS100D Solar Suitcase 60W and 100W Owner s Manual

PEIMAR S OFFICIAL BROCHURE - UK VERSION

NE (SE) Beam

Sunrise: 05:48 N (S) Beam

PEIMAR S OFFICIAL BROCHURE - USA

Installation and Safety Manual

Details and specification for 30 W solar powered LED street lights.

F-Series 30W PV Module SPM030P-WP-F

SOLAR ENERGY KIT MODEL: SISMA-CS3500

Where. Where there s sun. there s SUNGEN.

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

Modeling and Comparison of Dynamics of AC and DC Coupled Remote Hybrid Power Systems

DC Submersible Solar Pump Model: RS5000

A 3-Year Case Study of a Residential Photovoltaic System with Microinverters

DC Submersible Solar Pump Model: RS1800

SOLAR ENERGY ASSESSMENT REPORT. For 115 kwp. Meteorological Data Source Meteonorm. Date 18 October, Name of Place California.

English be1202. Europen Photovoltaic Industry Association

POWER OPTIMIZERS. SolarEdge Power Optimizer. Module Embedded Solution OPJ300-LV. PV power optimization at the module-level.

Suntech Power Cutting-Edge Technology

100kW GROUND MOUNTED SOLAR PHOTOVOLTIC POWER PLANT DETAILED PROJECT REPORT AERO SPACE MATERIALS PVT LTD

Solar Photovoltaic Panels

My Home Solar PhotoVoltaic (PV) System 2010 through 2017 How s It Doing?

10KW 3 Phase Off Grid Hybrid System

PS4000 HR/C SOLAR-OPERATED SUBMERSIBLE PUMP SYSTEMS MANUAL FOR INSTALLATION, OPERATION, SERVICE. Sun. Water. Life.

Datasheets. Residential On-Grid Photovoltaic System Kits

CEYLON SOLAR POWER (PVT) LTD.

OFF GRID PV POWER SYSTEMS SYSTEM DESIGN GUIDELINES FOR THE PACIFIC ISLANDS

SPG-400. Solar-powered generators

The complete solar water pumping solution with SmartSolution hybrid power support

SPECIAL SPECIFICATION 6576 Solar Panel Power Supply System

Eclipse Solar Suitcase

IDCOL Technical Standard for Solar Irrigation Pump (SIP) Projects

TripleLynx Inverter Range MAKING MODERN LIVING POSSIBLE. The benchmark solar inverter from Danfoss 3 phase Transformerless 8, 10, 12.

Crystalline Silicon PV Module Installation Guide (JET)

SOLAR ENERGY KIT MODEL: SEM-CS3000

DATASHEET PLECTRE - SOLAR CELL LIGHTING COLUMN

MANBLAN Hybrid Powered Landscape Lights SL C-00-5 <Assembly Type>

SETEC Power Co.,Ltd

sun Find us at : Website : SGS QMS MNRE APPROVED ISO 9001 SAAR ISPL System Cert

Rooftops requiring a building integrated solar solution with no roof penetrations

Sample Solar PV Electrical One Line

Transcription:

Parameter Location: Afghanistan, Baglan (36 North; 68 East) Water temperature: 25 C Required daily output: 50 m³; Sizing for average month Dirt loss: 2.0 % Motor cable: 100 m Pipe type: - Total dynamic head: 80 m Pipe length: - Products Quantity Details PS2-4000 C-SJ5-25 LC260-P60 Motor cable 1 pc. Submersible pump system including controller with DataModule, motor and pump end 24 pc. 6,240 Wp; 8 x 3 modules; 36 tilted 100 m 6 mm² 3-phase cable for power and 1-phase cable for ground Accessories 1 set Well Probe, Surge Protector, PV Disconnect 440-40-3 Sun Sensor setting in PumpScanner min. 150 W/m² Daily output in average month 52 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av. Output [m³] Energy [kwh] 23 27 30 33 35 38 37 37 36 34 28 21 32 Irradiation [kwh/m²] 3.6 4.4 4.9 5.7 6.2 6.7 6.7 6.6 6.3 5.7 4.5 3.4 5.4 Rainfall [mm] 1.3 1.7 2.4 1.8 0.83 0 0.033 0 0 0.27 0.73 0.93 0.83 Ambient temp. [ C] 1 2 7 13 18 23 26 24 19 12 8 3 13 Hourly values 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 Output [m³/h] Energy [kwh] 0.15 0.82 1.9 2.9 3.7 4.2 4.4 4.2 3.7 2.8 1.9 0.79 0.14 Irradiation [kwh/m²] 0.024 0.13 0.31 0.49 0.64 0.73 0.76 0.73 0.64 0.49 0.31 0.13 0.024 Ambient temp. [ C] 8 8 9 11 13 15 17 18 18 18 18 17 17 1/5

System characteristic Min. 800 W/m², 20 C Max./STC* PV generator Cell temperature [ C] 46 25 Temperature loss [%] 8.8 - Dirt loss [%] 2.0 - Pmax [Wp] 4,460 6,240 Vmp [V] 228 250 Imp [A] 20 25 Voc [V] 276 303 Isc [A] 21 26 Pout [W] 3,250 - Vout [V] 259 - Iout [A] 12 - Motor cable Power loss [%] 1.3 3.6 3.7 Pump systems Motor power [W] 342 3,105 3,105 Motor voltage [V EC] 127 222 222 Motor current [A] 2.7 14 14 Motor speed [rpm] 2,135 3,135 3,135 Flow rate [m³/h] 0 6.1 6.1 Efficiency [%] 0 41 47 *STC: Standard test conditions for photovoltaic modules, 1000 W/m² solar iradiance, 25 C cell temperature 2/5

Wiring diagram 3/5

System Layout 1: PS2 Controller 2: Submersible Pump 3: Flow Sleeve 4: Well Probe 5: Cable Splice Kit 6: Grounding Rod 7: Surge Protector* 8: Safety Rope 9: Water Meter 10: Pressure Sensor 11: Float Switch 12: Sun Switch 13: PV Disconnect 14: Lightning Surge Protector 15: PV Generator *It is recommended to install a Surge Protector at each controller sensor input. 4/5

Sizing Layout H (Static head): B (Drawdown): D (Pipeline inner diameter) L (Pipe length): M (Motor cable): T (Tilt angle): Vertical height from the dynamic water level to the highest point of delivery. Lowering of water level depending on flow rate and recovery rate of the well. Entire pipeline from the pump outlet to the point of delivery. Ellbows and armatures must be added as an equivalent length of pipeline. The cable between controller and pump unit. Angle of the PV generator surface from the horizontal plane. 5/5

PS2-4000 C-SJ5-25 Solar Submersible Pump System for 4" wells System Overview Head Flow rate Technical Data max. 140 m max. 7.0 m³/h Controller PS2-4000 Controlling and monitoring Control inputs for dry running protection, remote control etc. Protected against reverse polarity, overload and overtemperature Integrated MPPT (Maximum Power Point Tracking) Integrated Sun Sensor Power max. 4.0 kw Input voltage max. 375 V Optimum Vmp** > 238 V Motor current max. 14 A Efficiency max. 98 % Ambient temp. -40...50 C Enclosure class IP68 Motor ECDRIVE 4000-C Maintenance-free brushless DC motor Water filled Premium materials, stainless steel: AISI 304/316 No electronics in the motor Rated power 4.0 kw Efficiency max. 92 % Motor speed 900...3,300 rpm Insulation class F Enclosure class IP68 Submersion max. 150 m Pump End PE C-SJ5-25 Non-return valve Premium materials, stainless steel: AISI 304 Optional: dry running protection Centrifugal pump Efficiency max. 54 % Pump Unit PU4000 C-SJ5-25 (Motor, Pump End) Borehole diameter min. 4,0 in Water temperature max. 50 C Standards 2006/42/EC, 2004/108/EC, 2006/95/EC IEC/EN 61702:1995 The logos shown reflect the approvals that have been granted for this product family. Products are ordered and supplied with the approvals specific to the market requirements. **Vmp: MPP-voltage under Standard Test Conditions (STC): 1000 W/m² solar irradiance, 25 C cell temperature BERNT LORENTZ GmbH & Co. KG Siebenstuecken 24, 24558 Henstedt-Ulzburg, Germany, Tel +49 (0)4193 8806-700, Pictures may differ from actual products depending on local market requirements and regulations.

PS2-4000 C-SJ5-25 Solar Submersible Pump System for 4" wells Pump Chart Vmp* > 238 V Dimensions and Weights Controller H1 = H2 = W1 = W2 = W3 = D1 = 352 mm 333 mm 207 mm 170 mm 164 mm 124 mm Pump Unit A = 941 mm B = 245 mm C = 696 mm D = 96 mm E = 98 mm S = 1.5 in Net weight Controller Pump Unit Motor Pump End 6.1 kg 18 kg 10 kg 8.0 kg *Vmp: MPP-voltage under Standard Test Conditions (STC): 1000 W/m² solar irradiance, 25 C cell temperature BERNT LORENTZ GmbH & Co. KG Siebenstuecken 24, 24558 Henstedt-Ulzburg, Germany, Tel +49 (0)4193 8806-700, Pictures may differ from actual products depending on local market requirements and regulations.

LC260-P60 High-efficiency PV Module Features high energy yields ensured by high conversion efficiency sturdy, clear-anodized aluminum frame with pre-drilled holes for quick installation advanced EVA encapsulation with triple-layer backsheet, meets the most stringent safety requirements for high-voltage operation pre-wired junction box equipped with connectors plug n play reliable bypass diodes to prevent overheating (hot spot effect) and to minimise power loss by shading manufactured in ISO 9001:2000-certified factory Warranty Warranty: 2 years Performance guarantee: up to 10 years (90% power output) up to 20 years (80% power output) Details according to warranty issued by LORENTZ Standards LC260-P60 is certified according to IEC 61215 and 61730 by TÜV Rheinland and meets the requirements for CE. Qualified, IEC 61215 Safety tested, IEC 61730 Periodic Inspection Specifications Electrical Data Peak power Pmax [Wp] 260 Tolerance [%] + 5/0 Max. power current Imp [A] 8.35 Max. power voltage Vmp [V] 31.2 Short circuit current Isc [A] 8.83 Open circuit voltage Voc [V] 37.9 Temperature co-efficient for Pmax [%/ C] -0.42 Temperature co-efficient for Voc [%/ C] -0.34 Temperature co-efficient for Isc [%/ C] 0.06 Max. system voltage [VDC] 1,000 Module efficiency [%] 16.36 Practical module efficiency [%] 17.80 All technical data at standard test condition: AM = 1.5, E = 1,000 W/m², cell temperature: 25 C Cells photo may differ from actual product Number of cells in series 60 Number of cells in parallel 1 Cell technology polycrystalline Cell shape rectangular To find out more visit BERNT LORENTZ GmbH & Co. KG Siebenstuecken 24, 24558 Henstedt-Ulzburg, Germany, Tel. +49 (0) 4193 8806-700 151118 Errors excepted and possible alterations without prior notice. Pictures may differ from actual products depending on local market requirements and regulations. A pump system consists of a controller, motor and pump end. Multiple pumps/pump ends are shown to represent the wide range of pumps (over 70) that LORENTZ has.

Electrical Performance Current [A] Electrical Performance Electrical Performance for different temperatures, at AM=1.5, E=1,000 W/m 2 for different irradiation, at 25 C 9 9 8 8 1,000 W/m 2 7 7 6 25 C 6 800 W/m 2 Current [A] 5 5 50 C 600 W/m 2 4 4 3 3 400 W/m 2 75 C 2 2 1 1 200 W/m 2 0 0 0 10 20 30 40 0 10 20 30 40 Voltage [V] Voltage [V] Normalised Isc, Voc and Pmax (%) Temperature Dependence Irradiation Dependence of Isc, Voc and Pmax of Isc, Voc and Pmax at 25 C 140 140 Normalised Isc, Voc and Pmax (%) 120 120 Isc 100 100 80 Voc 80 Pmax 60 60 40 40 20 20 Voc Isc Pmax 0 0-25 0 +25 +50 +75 100 0 200 400 600 800 1000 1,200 Cell temperature [ C] Irradiance [W/m 2 ] Physical Specifications mm A A A A 9 14 A A 9 14 1,650 [65.0] Ø 4 870 [34.3] 1,370 [53,9] A A 992 [39.1] 35 [1.4] 942 [37.1] 11 [0.44] Weight [kg] 18.5 Dimension [mm] 1,650 992 35 35 [1.4] A A Strength [N/m 2 ] 2,400 Cable approx. 900 mm, 4 mm 2 Connectors MC4 compatible 35 [1.4] To find out more visit BERNT LORENTZ GmbH & Co. KG Siebenstuecken 24, 24558 Henstedt-Ulzburg, Germany, Tel. +49 (0) 4193 8806-700 151118 Errors excepted and possible alterations without prior notice. Pictures may differ from actual products depending on local market requirements and regulations. A pump system consists of a controller, motor and pump end. Multiple pumps/pump ends are shown to represent the wide range of pumps (over 70) that LORENTZ has.