Data Sheet 3.11 Issue F

Similar documents
Data Sheet 3.03 Issue D

Data Sheet 3.01 Issue C

Model VKFD28 Flexible Sprinkler Drops (LPCB Approved) Installation Manual. January 2016 Form No. F_ Rev 16.1

I-VICFLEX.AB7 VicFlex Sprinkler Fittings for Ceiling Suspension Systems STYLE AB7

I-VICFLEX.AB5. Victaulic VicFlex Style AB5 Sprinkler Fitting for Wood or Metal Joists/Studs and CD Profile (60 mm) Channel Ceiling Systems WARNING

I-VICFLEX.AB11. Victaulic VicFlex Style AB11 Low-Profile Sprinkler Fitting for Suspended Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

Flexible Sprinkler Connector Braided & Unbraided

I-VICFLEX.AB1/AB2/AB10

Flexible Sprinkler Connections

KOFULSO /Easyflex flexibles sprinklers drop distributed by

INSTALLATION INSTRUCTIONS FOR DECK TUB SETS with HAND SHOWER Valves Numbered: &

PROFLEX FLEXIBLE SPRINKLER HOSES (PAGE 1/5)

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA SPRINKLER ESCUTCHEONS

Inverted High Pressure Fluid Filters

Victaulic Fittings, Couplings, Valves & Sprinkler Heads for the Fire Sprinkler Market Keeping the art of distribution simple

Listings and Approvals. G5 QR Gasket culus QR G5 SR Gasket culus, FM SR G5

FAX

Paint/Solvent/Dump Valve and Flow-Through Valve

Male stud fittings. Male stud elbow. Fluid... Working pressure... Vacuum level... Rated temperature...

FRAME STYLE SPRAY NOZZLES TECHNICAL DATA

B21 Series BASOTROL Gas Valve

GENERAL INSTALLATION MANUAL

Fire Protection Systems

Grinnell Grooved Fire Protection Products Grooved Fittings

SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems.

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less.

Model RM-1 Riser Manifold Commercial and Residential General Description

TECHNICAL DATA OBSOLETE

Instructions for Installation, Operation, Care and Maintenance

ONE TOUCH FITTINGS Series WP2

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK. This work covers part of outcome 2 of the Edexcel standard module:

Section 2. Shurjoint Grooved Fittings Flow Data / Friction Resistance Ductile Iron Grooved Fittings. Wrought Grooved Fittings

Standard Specifications

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

100 SERIES & 120 SERIES HOSE

TECHNICAL DATA. Trimpac 244a. April 15, 2011

Installation Instructions

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Installation Instructions

GW THERMOCOOL NOZZLE STRUCTURAL STEEL PROTECTION

Easy Riser swing check valve Models E-1 & F-1

P239-1 Supply Pumper Instructions

TECHNICAL DATA. Trimpac 249a. September 16, 2013

INSTALLATION INSTRUCTIONS Auto Level Compressor Kit IMPORTANT NOTES

Standard Specifications

Carbon or stainless Steel

HPS SERIES. Steam Joints DEUBLIN COMPANY Norman Drive, West Waukegan, IL USA Phone: 847/ Fax: 847/ Rev.

model E Spray nozzles vk810 - vk817

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

FUEL KITS P/N & 526-2

mirage standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6)

Instruction Manual. Single Acting Hydraulic Aluminium Pull Cylinders RAP Series. Maximum Operating Pressure 700 bar

Speed Controller with One-touch Fitting

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

HYDROSTATIC TEST SYSTEM MANUAL

Miniature Regulator Series ARJ310

VANDAL RESISTANT FITTINGS VR105, VR125, VR145 (VR106, VR115 Export only) PRODUCT MANUAL IMPORTANT

Priming Systems Installation Instructions

Installation Instructions

SEries 41 check valve installation, operation & maintenance manual

Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of.05 gpm/ft 2

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

OWNER S MANUAL. ROTARY SURFACE CLEANER Models 105C, 105F, 105CW, & 105FW. Revision 2.01

Installation Instruction for Valve: DFPHY.ID Trim Application: Pressure Balance Tub & Shower

Standard Specifications

FAX

Installation guidelines. The system comprises of two basic circuits. These are:

argco.com

DELUGE VALVE DATA SHEET

TECHNICAL DATA CAUTION

Inverted Dual High-Pressure Fluid Filter Assemblies

Document: 3 inch Vane Pump System-in-a-Box Assembly Instructions SPS100370

Directional Spray Nozzles, Open, with Strainers High Velocity General Description

TIDALFLUX 2300 F Quick Start

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

Installation Instructions

Data Sheet Issue A

FIRE PROTECTION PRODUCTS

Worldwide Contacts.

SECTION COMPRESSED-AIR PIPING FOR LABORATORY FACILITIES


INSTALLATION INSTRUCTIONS

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

Welker Automatic Insertion Diffusing Probe Model AIP-3DP

Hole-cutting. cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8 (16mm) of the hole

Technical Data. UL Listing is based on the following criteria:

Micro24 TM Hose & Tube System

One Million Raindrops by Senju Sprinkler. Product Brochure

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure

Installation Guide. Single-Control Bath and Shower Trim A K K K 12021

Installation & Operator s Manual

TECHNICAL DATA VK810 (65 ) VK811 (80 ) VK812 (95 ) VK813 (110 )

SPEAKMAN. SE-675 Installation, Operation, and Maintenance Instructions SAFE-T-ZONE EMERGENCY SHOWER AND EYE/FACE WASH

Part No: Genuine Mira Accessories

Model F1 Model F1 Recessed Standard Response Sprinklers

smart irrigation solutions

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

Transcription:

General Description Rapidrop flexible sprinkler hoses are typically used as an alternative to traditional hard pipe arm overs and are particularly suited for use in suspended ceiling applications. The Rapidrop flexible sprinkler hose is an adjustable, braided, helical corrugated stainless steel connection that removes the need for cutting, threading, welding or precise measurements. The benefits are considerable for the installer and the building owner. Reduced install time, Easily formed by hand, Requires only normal hand tools, Centre of tile and correct vertical position first time every time, Self-supporting so no intermediate supports are required on lengths below 1.6 metres, Full system pressure test can be accommodated at first fix stage, no need to drain down for second fix, just depressurise, therefore no system refill or second pressure test, Sprinkler heads even when operated at maximum pressure have no adverse effects upon the ceiling suspension system, A large range of ceiling support brackets are available to suit different ceiling systems including lift out tile, fixed board and many other types. Brackets to accommodate all sprinkler types such as concealed, flush pendent and pendent heads are also available. With numerous inlet, outlet and bracket options, Rapidrop flexible sprinkler hoses are supplied in kit form containing only the specific components required. Technical Details Max. Working Pressure 12 bar / 175 PSI () 16 bar / 232PSI (LPCB) Max. Ambient Temperature 107 C / 225 F Approvals Approved LPCB Min. Bend Radius of Flexible Hose Connection to Branch Line (Inlet) 165mm / 6½ () 75mm / 3 (LPCB) 1 BSPT / 1 NPT 1 1 / 4 BSPT / 1 1 / 4 NPT Material Specification Description Material Flexible hose Stainless Steel 304 Nut Carbon Steel, Zinc Plated Isolation ring Nylon 66 Seal NBR Outlet Reducer Carbon Steel, Zinc Plated Connection to the Sprinkler (Outlet) Max K-Factor ½ BSPT / ½ NPT ¾ BSPT / ¾ NPT Straight or 90º Elbow K200 (K14) () K80 (K5.6) (LPCB*) *LPCB LPS1261 iss3.0 limits all flexible sprinkler connections to K80 (K5.6) NOTE: The flexible stainless steel hose should not be bent within 65mm (2½ ) of the connection nut at both ends. Inlet Nipple Centre Bracket A Side Bracket B Square Bar Carbon Steel, Zinc Plated Carbon Steel, Zinc Plated Carbon Steel, Zinc Plated Carbon Steel, Zinc Plated w: www.rapidrop.com Page 1 of 12 reserves the right to change the design, materials and specifications without notice to continue product development

Pressure Loss Data Model Minimum Bend Radius mm (inch) Number of Bends Rated Working Pressure bar (psi) Hose Assembly length Straight outlet mm(inch) Elbow outlet mm(inch) 1/2 outlet K80 (K5.6) Equivalent Length of 1 in. Schedule 40 Pipe 3/4 outlet K115 (K8.0) 3/4 outlet K160 (K11.2) Straight outlet m (ft) 90º Elbow outlet m (ft) 3/4 outlet K200 (K14) RD-SMB-01 1 780 (31) 7 (23) 8.3 (27.2) 5.1 (16.8) 6.9 (22.8) 5.4 (17.7) 6.9 (22.6) 5.6 (18.4) 6.7 (21.9) RD-SMB-02 3 1000 (39) 9.6 (31.4) 10.2 (33.7) 7.9 (25.8) 8.1 (26.8) 7.9 (25.8) 7.9 (26.2) 7.9 (25.9) 7.9 (25.9) 165 12 RD-SMB-03 3 1220 (48) (6 1 / 2 ) (175) 12.1 (39.8) 12.2 (40) 10.6 (34.8) 9.4 (30.9) 10.2 (33.5) 9.1 (29.9) 10.2 (33.4) 9.1 (30) RD-SMB-04 4 1540 (60) 13.9 (45.6) 15.1 (49.6) 12.6 (41.4) 12.5 (40.9) 12.4 (40.7) 12.2 (40.1) 12.4 (40.8) 12.5 (41.1) RD-SMB-05 4 1830 (72) 15.5 (50.9) 17.8 (58.4) 14.4 (47.3) 15.2 (49.9) 14.4 (47.2) 15 (49.4) 14.5 (47.6) 15.6 (51.2) Pressure Loss Data LPCB Model Minimum Bend Radius mm (inch) Number of Bends Rated Working Pressure bar (psi) Hose Assembly length mm (inch) Equivalent Length of DN 25 BS EN 10225 Pipe 1/2 outlet, Straight or 90º Elbow K80 (K5.6) m (ft) RD-SMB-01 1 780 (31) 2.2 (7.2) RD-SMB-02 3 1000 (39) 5.3 (17.4) 75 RD-SMB-03 3 (3) 16 (232) 1220 (48) 6.3 (20.7) RD-SMB-04 3 1540 (60) 7.1 (23.2) RD-SMB-05 3 1830 (72) 7.7 (25.2) Note: Tables above shows pressure loss figures for the flexible hose with maximum number of bends. Pressure loss of the hose with fewer bends than shown in the tables will be lower. w: www.rapidrop.com Page 2 of 12 reserves the right to change the design, materials and specifications without notice to continue product development

Important Installation Information Rapidrop Flexible Sprinkler Hose must only be installed by an appropriately qualified person in accordance with the requirements of the local authority having jurisdiction. Deviations from these standards will void any warranty. Alterations to Rapidrop products will void any warranty. Rapidrop Flexible Sprinkler Hose, brackets and fittings must not be intermixed with other manufacturer s products. The flexible stainless steel hose should only be installed inside buildings and protected from freezing temperatures. In the event that a flexible sprinkler hose is installed and the ceiling structure to be completed at a later date, it is the responsibility of the installer to ensure that the flexible sprinkler hose is suitably supported in order to reduce the bending moment on the top joint and give adequate protection from other trades. It is the responsibility of the system designer to verify suitability for use of chemical exposure, water additives, temperature, UV exposure. If in doubt contact the manufacturer. System designer or responsible person should check with the Rapidrop sales representative that the flexible hose meets the local water regulations. The flexible hose should not be bent or manipulated when pressurized. Hose connections should not be tightened or adjusted when system is pressurised. Flexible stainless steel hose and fittings have limited flexibility and are intended only to be installed with bends at their respective minimum bend radii. Hose connections should not be tightened by rotating the nipple or reducer as it may result in damage to the seal. The flexible stainless steel hose should not be bent within 65 mm (2 1/2 inches) of its connection nuts The owner is responsible for maintaining the fire protection system in proper operating condition. Flexible hose to be inspected and maintained during routine sprinkler system inspections by a qualified inspection service in accordance with national codes/requirements. MIN BEND RADIUS MIN BEND RADIUS MIN BEND RADIUS w: www.rapidrop.com Page 3 of 12 reserves the right to change the design, materials and specifications without notice to continue product development

Installation of A2 type centre bracket with metal ceiling suspension system 1. Install the Inlet Nipple in the Branch Pipe outlet using the normal sealing and tightening methods for connecting pipe threads. Tighten firmly with a pipe wrench for leak proof connection. 2. Remove plastic Protecting Cap from one end of the flexible hose, check that the black rubber seal is in place and connect the Outlet Reducer (M33 x 1.5 thread end) to that end. To prevent reducer from turning, securely hold in place whilst tightening the hose nut. Tighten to a torque of 20 Nm/15 ft-lbs. Do not exceed the specified torque. Do not use joint compound or PTFE tape on the M33 threads. w: www.rapidrop.com Page 4 of 12 reserves the right to change the design, materials and specifications without notice to continue product development

3. Remove plastic Protecting Cap from the other end of the flexible hose, check that the black rubber Seal is in place and connect that end to the inlet nipple on the range pipe and tighten the nut to a torque of 20 Nm/15 ft-lbs). 6. Attach square bar to the side B brackets, tighten the top screws. 4. Bend the flexible hose to achieve the required routing maintaining the minimum bend radius and position the reducer for sprinkler location. When bending the hose allow 65mm of straight hose from the nut, ensure there are no kinks. 7. Slide A2 type centre bracket onto the square bar, mount the outlet reducer through the centre bracket and lightly tighten the nut. Adjust location of the centre bracket and the side brackets until desired location of the outlet reducer is achieved. Firmly secure the side brackets by tightening the screws to a torque of 5 Nm/4 ft-lbs. 5. Attach side B Brackets to the main runners of the suspended ceiling using screws provided. Lightly tighten side screws to hold brackets on the ceiling grid rails. w: www.rapidrop.com Page 5 of 12 reserves the right to change the design, materials and specifications without notice to continue product development

8. Apply a non-hardening pipe joint compound or PTFE tape to the male thread of the sprinkler head and install in the Outlet Reducer according to the sprinkler head manufacturer s instructions, using the wrench supplied by the manufacturer. When installing the sprinkler head with a two piece escutcheon, the inner piece should be mounted on the thread of the sprinkler head before attaching to the reducer. 9. Adjust height of the Outlet Reducer until desired location of the sprinkler is achieved. Firmly secure the Centre Bracket by tightening the screws to a torque of 5 Nm/4 ft-lbs). 10. After installation is complete, test the sprinkler system for leaks in accordance with Authority Having Jurisdiction. It is advised to not leave the sprinkler system drained for long periods. The Rapidrop Flexible Hose assembly must be fixed to full height cross tees of the suspended ceiling system using support bar and brackets supplied. The Rapidrop Flexible Hose end B Brackets are not compatible with reduced height or lightweight cross tees. If there are no full height cross tees available, Rapidrop Flexible Hose assembly must be fixed to the Main Runners of the suspended ceiling system. As the Main Runners are usually spaced at 1,200mm this method requires a longer support bar which is available. Various types of B Brackets are available to suit the suspended ceiling Cross Tees and Main Runners, with heights to suit both spray pendent sprinklers with escutcheons and concealed sprinklers. Do not over tighten bracket screws. w: www.rapidrop.com Page 6 of 12 reserves the right to change the design, materials and specifications without notice to continue product development

Installation of ARF02 Quick Fit bracket with metal ceiling suspension system 1. Install the Inlet Nipple in the branch pipe outlet using the normal sealing and tightening methods for connecting pipe threads. Tighten firmly with a pipe wrench for leak proof connection. 2. Remove plastic Protecting Cap from one end of the flexible hose, check that the black rubber seal is in place and connect the Outlet Reducer (M33 x 1.5 thread end) to that end. To prevent reducer from turning, securely hold in place whilst tightening the hose nut. Tighten to a torque of 20 Nm/15 ft-lbs. Do not exceed the specified torque. Do not use joint compound or PTFE tape on the M33 threads. w: www.rapidrop.com Page 7 of 12 reserves the right to change the design, materials and specifications without notice to continue product development

3. Connect Centre Bracket ARF02 to the Outlet Reducer with the tab facing up and lightly tighten the wing nut. 5. Remove plastic protecting cap from the other end of the flexible hose, check that the black rubber Seal is in place and connect that end to the inlet nipple on the range pipe and tighten the nut to a torque of 20 Nm/15 ft-lbs. 4. Apply a non-hardening pipe joint compound or PTFE tape to the male thread of the sprinkler head and install in the Outlet Reducer according to the sprinkler head manufacturer s instructions, using the wrench supplied by the manufacturer. 6. Bend the flexible hose to achieve the required routing maintaining the minimum bend radius and position the reducer for sprinkler location. When bending the hose allow 65mm of straight hose from the nut, ensure there are no kinks. If assembly of the ceiling structure has not been completed it may possible to pressurise the system and perform first pressure test at this stage 7. Attach square bar with preassembled side B Brackets or optional separate square bar and B brackets to the main runners of the suspended ceiling. Lightly tighten wing screws to hold brackets on the ceiling grid rails. When installing the sprinkler head with a two piece escutcheon, the inner piece should be mounted on the thread of the sprinkler head before attaching to the reducer. w: www.rapidrop.com Page 8 of 12 reserves the right to change the design, materials and specifications without notice to continue product development

8. Lift the tab of the ARF02 centre bracket and attach it to the square bar. Lightly tighten the wing screw. 9. Adjust height of the Outlet Reducer until desired location of the sprinkler is achieved. Firmly secure the Centre Bracket by tightening the wing screw to a torque of 5 Nm/4 ft-lbs). 10. After installation is complete, test the sprinkler system for leaks in accordance with Authority Having Jurisdiction. It is advised to not leave the sprinkler system drained for long periods. The Rapidrop Flexible Hose assembly must be fixed to full height cross tees of the suspended ceiling system using support bar and brackets supplied. The Rapidrop Flexible Hose end B Brackets are not compatible with reduced height or lightweight cross tees. If there are no full height cross tees available, Rapidrop Flexible Hose assembly must be fixed to the Main Runners of the suspended ceiling system. As the Main Runners are usually spaced at 1,200mm this method requires a longer support bar which is available. Various types of B Brackets are available to suit the suspended ceiling Cross Tees and Main Runners, with heights to suit both spray pendent sprinklers with escutcheons and concealed sprinklers. Do not over tighten bracket screws. w: www.rapidrop.com Page 9 of 12 reserves the right to change the design, materials and specifications without notice to continue product development

Installation of A1 centre bracket with metal ceiling suspension system 1. Install the Inlet Nipple in the branch pipe outlet using the normal sealing and tightening methods for connecting pipe threads. Tighten firmly with a pipe wrench for leak proof connection. 2. Remove plastic Protecting Cap from one end of the flexible hose, check that the black rubber Seal is in place and connect that end to the inlet nipple on the range pipe and tighten the nut to a torque of 20 Nm/15 ft-lbs). w: www.rapidrop.com Page 10 of 12 reserves the right to change the design, materials and specifications without notice to continue product development

3. Attach side B Brackets to the main runners of the suspended ceiling using screws provided. Lightly tighten side screws to hold brackets on the ceiling grid rails. 6. Remove plastic Protecting Cap from the other end of the flexible hose, check that the black rubber seal is in place and connect the Outlet Reducer (M33 x 1.5 thread end) to that end. To prevent reducer from turning, securely hold in place whilst tightening the hose nut. Tighten to a torque of 20 Nm/15 ft-lbs. Do not exceed the specified torque. 4. Slide A1 Centre Bracket onto the Square Bar. 5. Attach square bar to the side B brackets, tighten the top screws. w: www.rapidrop.com Page 11 of 12 reserves the right to change the design, materials and specifications without notice to continue product development

7. Apply a non-hardening pipe joint compound or PTFE tape to the male thread of the sprinkler head and install in the Outlet Reducer according to the sprinkler head manufacturer s instructions, using the wrench supplied by the manufacturer. When installing the sprinkler head with a two piece escutcheon, the inner piece should be mounted on the thread of the sprinkler head before attaching to the reducer. 8. Bend the flexible hose to achieve the required routing maintaining the minimum bend radius of (inner edge) and position the reducer for sprinkler location. When bending the hose allow 65mm of straight hose from the nut, ensure there are no kinks. 9. Mount the outlet reducer through the A1 centre bracket and lightly tighten the wing bolt. Adjust location of the centre bracket and the side brackets until desired location of the outlet reducer is achieved. Firmly secure the side brackets by tightening the screws to a torque of 5 Nm/4 ft-lbs. The Rapidrop Flexible Hose assembly must be fixed to full height cross tees of the suspended ceiling system using support bar and brackets supplied. The Rapidrop Flexible Hose end B Brackets are not compatible with reduced height or lightweight cross tees. If there are no full height cross tees available, Rapidrop Flexible Hose assembly must be fixed to the Main Runners of the suspended ceiling system. As the Main Runners are usually spaced at 1,200mm this method requires a longer support bar which is available. Various types of B Brackets are available to suit the suspended ceiling Cross Tees and Main Runners, with heights to suit both spray pendent sprinklers with escutcheons and concealed sprinklers. Do not over tighten bracket screws. 10. Adjust height of the Outlet Reducer until desired location of the sprinkler is achieved. Firmly secure the Centre Bracket by tightening the wing bolt to a torque of 5 Nm/4 ft-lbs). Important Installation Information Rapidrop Braided Flexible Sprinkler Hose must only be installed by a competent person in accordance with requirements of the local authority having jurisdiction. Deviations from these standards will invalidate warranty. It is the responsibility of the installing contractor to include a copy of this document in the sprinkler system installation, operating and maintenance manual. Alterations to Rapidrop products will void any warranty. Braided Flexible Sprinkler Hose should be inspected and maintained during routine sprinkler system inspections by a competent person in accordance with national codes/requirements. Failure to follow these instructions could cause improper operation, resulting in personal injury and/or property damage. For further details and technical support please contact your Rapidrop sales representative. w: www.rapidrop.com Page 12 of 12 reserves the right to change the design, materials and specifications without notice to continue product development