INSTALLATION GUIDE Works in double and single ended wiring.

Similar documents
READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Specification Grade Contemporary Wall Mount/Technical Installation Data

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

INSTALLATION INSTRUCTIONS

Captivate Illuminated Mirror Light

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

MAXLITE RKT LED Retrofit Kit

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

IMMERSION. imagination at work. Retrofit Installation Guide. GE Lighting. LED Refrigerated Display Lighting

IMMERSION. imagination at work. LED Refrigerated Display Lighting. Vertical Cases RV40 Series LED Drivers GEPS4000NCMUL-SY

LED 2/3/4ft T8 Tube 120V

Instruction/Installation Manual

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

Product Installation Instruction LED Tube Lamp Retrofit Kits

MOONRING 1.5 MOONRING 3

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

INSTALLATION INSTRUCTION Bollard Light 12V

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

Wet Rated Batten LED Luminaire

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

LED VAPOR PROOF FIXTURE

WARNING / AVERTISSEMENT

TECTONIC LED CORP. ISO

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

IMMERSION. GE Lighting. OEM Installation Guide. imagination at work. LED Display Lighting


Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Iconic LED, LLC. "All in one T8" Compatible with or without ballast. WorkswithSingleEndandDoubleEnd

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

LED Recessed Troffer Retrofit Kit

Troubleshooting Guide

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Universal Retrofit System Installation Instructions Revised:

UB-2 2 Universal Button

Cable Cubby 1202 and 1402 Installation Guide

Electric Vehicle Supply Equipment

LAL SERIES LED LUMINAIRE

FITTING INSTRUCTIONS FOR CP0404BL/WH NO-CUT AERO CRASH PROTECTORS HUSQVARNA 701 ENDURO/SUPERMOTO 2016-

Lumination TM LED Luminaires LAL Series - Continuous Run Option

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Solid State T8 tube is the smart alternative to a

MNBE-8D2x2 INSTRUCTIONS

I. Pendant Mount Installation

Cable Cubby 500 and 700 Installation Guide

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

T8 Tube Light. UL LISTED & cul LISTED & DLC LISTED. Germany Patent: Gebrauchsmusters / Nr

UNPACKING THE UNIT. Alcohol cleaning pad

Cable Cubby 1200 and 1400 Installation Guide

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

INSTALLATION INSTRUCTIONS

Algae Control System. SEE INSTRUCTIONAL VIDEOS: sonicsolutionsllc.com

HOMELINK DOOR OPENER KIT

FOR INDOOR/SEASONAL USE ONLY

Zurik EMLV LED Driver

Lumination TM LED Luminaire LUR Series

EM converterled BASIC Installation and wiring instructions

NL-FTPR150, FUNCTIONAL TRAINER ASSEMBLY INSTRUCTIONS

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02

Spun Bay Installation Standard Version (non dimmable), Hook Mount

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTION

LED VaporProof Fixture

INSTALLATION INSTRUCTIONS. Double Wall, Drain Valve, BSPT. Torque Wrench w/ 100 to 150 ft-lbs. Setting

INSTALLATION GUIDE FOR VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Cable Cubby 650 UT Installation Guide

Installation Instructions

TM-11x1 Series Room Temperature Module

An Urgent Bulletin from CSA Group

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

Electric Vehicle Supply Equipment

CSD Series Current Devices Split Core

Portable Lawn Sprinkler and Multi-Use Pump

Parent s Guide. This guide contains important information. Please keep it for future reference US

Acme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual

FITTING INSTRUCTIONS FOR CP0393BL AERO CRASH PROTECTORS SUZUKI GSX-S

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Instruction Sheet ERK-XXXXKD SERIES KNOCKDOWN STANDALONE RACK

INSTALLATION INSTRUCTIONS

Palomino BATTERY CHARGERS. Installation and Operating Instructions. One Technology Place Caledonia, New York The Power of Excellence

INSTALLATION INSTRUCTION

Assembly and Operation Manual

Transcription:

ISTAATIO GUIDE Works in double and single ended wiring. -1-

Safety Precautions For your and others safety, please read the precaution carefully before installation: (1). Product should be installed by qualified electrician. (2). Switch off the power supply before commencing work, make sure all wiring connections are correct before powering on. For single ended wiring installation Removing fluorescent lamp system OTE: Westinghouse T8 ED tube is suitable to be installed in T8 standard luminaries. 1. Disconnect power from luminaire. 2. Remove fluorescent bulb. 3. Remove wiring compartment cover. 4. Cut all wires which are connected to the ballast and remove it. STOP! DO OT install this product in a luminaire that uses shunted lamp holders (found in all fixtures with instant start ballasts). Installing this product with shunted lamp holders will cause a short circuit condition in the lamp holder and create a fire or shock hazard. Before continuing, determine if the lamp holders currently installed in the luminaire are shunted or non-shunted. If the current lamp holders are shunted, cut the wires away from the lamp holders and install non-shunted lamp holders, making new connections with the lead wires at terminals indicated here: on-shunted lampholder OTE: If using existing non-shunted lamp holders, installer should not disconnect lead wires from lamp holders and make new connections at terminals. Instead, cut lead wires near ballast and make new connections to lead wires using approved connectors. -2-

Retrofitting fixtures with OE AMP OTE: Only one end of this ED tube receives power. The powered end is indicated by mark with & on the tube itself. Before begining installation, determine which end of the fixture will be the powered end and which end will be the dead end. 1. Make sure AC power to luminaire is OFF 2. Make sure ground wire from AC supply is securely connected to ground screw inside luminaire. 3. Connect black (live) and white (neutral) lead wires from lamp holders on powered end to incoming AC supply black (IVE) and white (EUTRA) wires with approved wire connectors. If only one lamp is being installed, proceed to step 4 below. o ive Connection ive eutral on-shunted ampholder Retrofitting luminaire with MUTIPE AMPS After completing steps 1-3 above, connect terminals on the powered lamp holder for first lamp to matching terminals on powered lamp holder for second lamp with black (live) and white (neutral) wires, being sure to maintain polarity. Repeat this daisy chain connection for each additional lamp. 1 E D Tu be 2 E D Tu be B A C K E D Tu be 1 B A C K E D Tu be 1 E D Tu be 2 4 E D Tu be 3 E D Tu be B A C K E D Tu be 1 B A C K E D Tu be 1 E D Tu be 2 E D Tu be 2 E D Tu be 3 E D Tu be 3 E D Tu be 4 4. When all connections are complete, place appropriate connectors/wire nuts on the end of any unused wires. 5. Replace wiring compartment cover. 6. Place sticker that is included with this product on wiring compartment cover or other conspicuous place on or inside of fixture. Sticker reads: This fixture has been modified. The ballast has been removed. DO OT install fluorescent lamps in this fixture. 7. Install ED tube(s), matching the end of the lamp that has the / sticker to the lamp holder that is connected to the ive and eutral wires. 8. Re-connect power to luminaire. -3-

For double ended wiring installation The below ballast wiring represents typical configuration. The actual ballast wiring varies according to ballast model. You do not need to change the socket (if in good condition) to operate double ended lamps, regardless the type of sockets. Please make sure one side of fixture is connected to ive () and the other side to eutral (). Wiring Instruction Instant Start Retrofit luminaire with 1 lamp Retrofit luminaire with 2 lamps Instant start -4-

Wiring Instruction Retrofit luminaire with 3 lamps Instant start..... Retrofit luminaire with 4 lamps Instant start -5-

Risk of fire or electric shock. Installation of this Retrofit Kit requires knowledge of electrical systems. If you are not qualified, do not attempt installation and contact a qualified electrician. Risq ue d'incendie ou de choc électrique. Installation de ce kit Rétrofit nécessite des connaissance spécifiques des systèmes électriques. Si vous n'êtes pas qualifié, n essayez pas de l'installer, et prenez contact avec un électricien qualifié. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and drawings. Installez ce kit dans les luminaires qui disposent des caractéristiques de conception et des dimensions indiquées sur les photographies et sur les schémas. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. e pas agrandir ou modifier les trous ouverts au sein du câblage ou sur les composants électriques lors de l'installation du kit. To prevent damage to wiring, do not expose wires to edges of sheet metal or other sharp objects. Pour éviter d'endommager le câblage ou à l'abrasion, ne pas exposer le câblage aux bords de tôle ou d'autres objets pointus. Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead installers should cut existing lamp holder leads away from the ballast and make new electrical connections to lamp holder lead wires by employing applicable connectors. es installateurs ne doivent pas débrancher les câbles existants de terminaux de support de lampe pour faire de nouvelles connexions dans les douilles. Au lieu installateurs doivent couper les câbles existants de terminaux de support de lampe et faire de nouvelles connexions électriques en utilisant des connecteurs applicables. THE RETROFIT ASSEMBY IS ACCEPTED AS A COMPOET OF A UMIAIRE WHERE THE SUITABIITY OF THE COMBIATIO SHA BE DETERMIED BY U OR AUTHORITIES HAVIG JURISDICTIO. E MOTAGE DU RETROFIT EST ACCEPTÉE COMME COMPOSAT D'U UMIAIRE OÙ A PERTIECE DE A COMBIAISO SERA DÉTERMIÉE PAR 'U OU ES AUTORITÉS AYAT A JURIDICTIO CORRESPODATE. THERE ARE ED TUBE, OPERATIO ISTRUCTIO AD FIED APPIED ABE I THIS RETROFIT KIT. WARIG - RISK OF FIRE OR EECTIRC SHOCK. DO OT ATER, REOCATE, OR REMOVE WIRIG, AMPHODERS, POWER SUPPY, OR AY OTHER EECTRICA COMPOET. AVERTISSEMET - RisqueS d'incendie ou de choc électrique. E PAS MODIER, REPACER OU DéBRACHER les CâBES, ES DOUIES D'AIMETATIO, OU TOUTE AUTRE COMPOSAT électrique. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. -6-