PARTS AND INSTALLATION MANUAL

Similar documents
CDS-JOHN BLUE COMPANY

SMPT OSA1 / 4. VISAGAGE ORIFICE SELECTOR Patent #9,433,144

DP DIAPHRAGM PUMP Parts & Instruction Manual

CDS-JOHN BLUE COMPANY

CDS-JOHN BLUE COMPANY

CDS-JOHN BLUE COMPANY

CDS-JOHN BLUE COMPANY

PARTS AND INSTALLATION MANUAL

DP-139 PUMP DIMENSIONS

ARAG Modular Manual Valve Operating Instructions and Parts Manual

AEROMOTIVE Volkswagen 1.8T Fuel Rail Part # INSTALLATION INSTRUCTIONS

DP-70-FP & DP-70.1-GRP DIAPHRAGM PUMPS

AS Centrifugal Pump Exploded View

25 GALLON PORTABLE OIL LIFT

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

ARAG Modular Electric Valve Operating Instructions and Parts Manual

Installation, Operation, Repair and Parts Manual

AEROMOTIVE Part # Ford 5.0 Liter INSTALLATION INSTRUCTIONS

Operations Manual. and. Seal Kit Replacement Guide

PPM EO-100 TM. Operation Manual

11101, & INSTALLATION INSTRUCTIONS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

DI-SP/TP. Operators Guide SUBMERSIBLE HYDRAULIC PUMPS HDI Inc. PO Box 1671 Gresham OR (FAX)

Reference Manual FM-200 Series

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

PARTS AND INSTALLATION MANUAL

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

MODEL 1385 & 1385-H Professional Rotary Drum Pump

IMPORTANT SAFETY INSTRUCTIONS

Operating and Installation Instructions

18324 INSTALLATION INSTRUCTIONS 65 PONTIAC LEMANS

MetroPrime 22MPC Self-Priming Centrifugal Pump

AEROMOTIVE Part # L 4V Fuel Rails INSTALLATION INSTRUCTIONS

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Manual Concentrate Management System

Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS

AEROMOTIVE Part # & Mustang Stealth Fuel Tank w/fuel pump INSTALLATION INSTRUCTIONS

PowerFLO 5800/5900 Series

DIRECT-DRIVE PRESSURE WASHERS

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

GARDEN HOSE UTILITY PUMP

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Utility Jack Model Number: HD HD HD

AEROMOTIVE Part # GM LS1 Fuel Rails INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # CHEVY/GMC Duramax Fuel System Kit RETRO FIT KIT FOR ½ LINES INSTALLATION INSTRUCTIONS

Motorized Stainless 2-Way Valves

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Installation, Operation, Repair and Parts Manual

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

G8 Portable Fuel Transfer Pump Owner s Manual

1 2-Inch Station Outlet Valves

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

Centrifugal Pump Warranty Guide

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Owner s Manual & Safety Instructions

Model GX Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

Owner s Manual WARNING

AEROMOTIVE Part # Subaru Fuel Rails for Top Feed Injectors WRX & STI INSTALLATION INSTRUCTIONS

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

AEROMOTIVE Part # Ford 5.4L Shelby GT500 Mustang INSTALLATION INSTRUCTIONS

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Installation, Operating and Maintenance Manual

ATD Gallon Pressurized Oil Drain Owner s Manual

Voltmaster Centrifugal Trash Pumps

SUBMERSIBLE MINI-PUMP

Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL HDE-1PH-230VFD

ESE Series Cast Iron Sewage Pumps

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

11202 INSTALLATION INSTRUCTIONS

Models P420A-3100 & P420A-5100

Scale Feeder Manifold Water Filtration System Instruction Manual

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Installation, Operation, Repair and Parts Manual

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

AEROMOTIVE Part # & Mustang 5.0L Stealth Fuel System Kit INSTALLATION INSTRUCTIONS

INSTALLATION AND SERVICE MANUAL

KC 5.5, 6, 6H, 7, 8, & 10 SERIES Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

P-200 Plastic Utility Pump for Petroleum Products

PARTS MANUAL 360 ROTATOR MODEL NUMBER R Industrial Way Lebanon, Oregon FORKLIFT ATTACHMENTS

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

SUNC3000 / Item #40885

Benron Equipment & supply, Inc.

Installation, Operation, Repair and Parts Manual

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

Installation Instructions. Application List Dodge 24V PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION

8000 / 10,000 / 12,000

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Models GP5132, GP5136, GP5142 & GP5145. Triplex Ceramic Plunger Pump Operating Instructions / Manual

36" Galvanized Direct Drive Hyflo Fan Installation and Operators Instruction Manual. Fan and Framing Dimensions

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

StormPro BA Series Sump Pump

Transcription:

PSP-3240 POLYPROPYLENE SELF-PRIMING 2 CENTRIFUGAL PUMP PARTS AND INSTALLATION MANUAL PSP-3240 Shown with GX-160 Honda CDS-JOHN BLUE COMPANY DIVISION OF ADVANCED SYSTEMS TECHNOLOGY, INC. 165 Electronics Blvd, Huntsville, AL 35824 Telephone: (256) 721-9090 - FAX: (256) 721-9091 Toll Free: 1-800-253-2583 Printed in U.S.A. 12-M-70 Rev 10/2018

SAFETY PRECAUTIONS: EQUIPMENT SHOULD BE OPERATED BY RESPONSIBLE PEOPLE. A CAREFUL OPERATOR IS THE BEST INSURANCE AGAINST AN ACCIDENT. FILL SYSTEM WITH WATER FIRST AND CHECK FOR LEAKS. REPLACE HOSES WHEN WORN OR CRACKED. WARNING: USE OF THIS PRODUCT FOR ANY PURPOSES OTHER THAN ITS ORIGINAL INTENT, ABUSE OF THE PRODUCT, AND/OR MODIFICATION TO THE ORIGINAL ANY/ALL SITUATIONS INVOLVING MISUSE, ABUSE OR MODIFICATION THE ORIGINAL INTENT OF THIS PRODUCT DOES NOT INCLUDE USE WHERE THE MAXIMUM ALLOWED PRESSURE OR TEMPERATURE IS EXCEEDED, AND IT DOES NOT INCLUDE APPLICATIONS UTILIZING FLUIDS THAT ARE NOT COMPATIBLE WITH THE PRODUCT S COMPONENT MATERIALS. DO NOT USE THIS PRODUCT WITH FLAMMABLE OR COMBUSTIBLE FLUIDS SUCH AS GASOLINE, KEROSENE, DIESEL, ETC... FAILURE TO FOLLOW THIS NOTICE MAY RESULT IN INJURY AND/OR SERIOUS PROPERTY DAMAGE AND WILL VOID THE PRODUCT WARRANTY. IF IN DOUBT ABOUT YOUR APPLICATION, CONTACT YOUR STOCKING DEALER OR THE CDS-JOHN BLUE TECHNICAL STAFF AT 1-800-253-2583. WARNING: This product can expose you to certain chemicals, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to: www.p65warnings.ca.gov. Note to the Owner The pump should be inspected annually for any wear or damage to any of the components in order to ensure proper operation. Enter the date of installation in the space provided for future reference. This information will be required for ordering replacement parts or servicing your pump. Our engineering department constantly improves its products. We reserve the right to make design and specification changes without notice. DATE OF INSTALLATION: 2018 CDS-John Blue Co. 2

Specifications: PSP-3240 shown with GX-160 Honda - Max flow: 200 gpm - Max pressure: 45 psi - Required HP: 5 Hp - Port size: 2 FPT Optional screw-in 220 flange adapter = 116287-01 - Materials: Polypropylene, Viton o-rings, 316 stainless bolts and shaft Loosen this bolt on pump for bracket tab 116395-91 Rail Kit Installation: - The standard pump is configured for gas engine use. For electric motor fitment, you must order a -E pump for use on a CDS-JBC 5hp motor (see page 6). - For mounting on a gas engine that is not mounted to a trailer or base, you may order a mounting rail kit as shown to the right, p/n 116395-91. 5/16-24 hardware is provided with the pump to mount it to the engine. - A shaft locating tool is used to hold the shaft during installation on the engine/motor. This must be removed before running the pump. - Note that any plumbing must be supported so that its weight does not hang off of the pump this will void the warranty. Remove tool before running pump - If you have the -FLG version of the pump with 220 flange fittings included, the fitting threads must have sealant applied before assembly to the pump. - The inlet configuration of the pump may be changed by removing the 6 locknuts holding the inlet on. The inlet check valve flap may also be removed in the high configuration. Using the pump in the high inlet condition allows the outlet hose to drain when the pump is shut off, which is beneficial to some users. Tighten all housing fasteners to 5 ft-lbs. Storage: After use flush the pump with a solution that will neutralize the fluid you have been pumping, and then drain. Do not use water to flush acids resulting damage not warrantied Center Inlet Configuration Maintenance: High Inlet Configuration The seal reservoir may be inspected by opening the fill plug. The fluid level should be around ½ below the opening. If the fluid is dirty, drain by tilting the pump upside down or pull it out with a vacuum, then replace with PREMIXED antifreeze. If the fluid is cloudy, the impeller side seal may be leaking. 2018 CDS-John Blue Co. 3

22 31 25 14 6 12 15 20 24 21 23 2 27 4 17 26 30 3A 32 3 28 29 13 19 (INSTALL NUT WITH IMPACT GUN) 18 28 11 7 10 1 16 9 12 6 8 27 5 10 2018 CDS-John Blue Co. 4

PARTS BREAKDOWN Seal & O-ring kit #116403-91 Item Description Part # 1 HOUSING 116282-01 2 BACKPLATE 116283-01 3/3A SCROLL PLATE / SCROLL PLATE INSERT 116284-01A / 02A 4 IMPELLER 116285-91 5 INLET FLANGE NPT 116286-01 6 ½ PLUG 116288-01 7 1 PLUG 116289-01 8 PIVOT PIN 316SS 116290-01 9 FLAP EPDM 116241-01 10 M220 FLANGE ADAPTER TO 2 MPT - OPTIONAL 116287-01 11 #123 VITON O-RING 1 PLUG 116293-01 12 #115 VITON O-RING ½ PLUG 116294-01 13 #139 VITON O-RING VOLUTE 116295-01 14 #049 VITON O-RING ENGINE ADAPTER 116296-01 15 M4X228 VITON O-RING HOUSING 116297-01 16 #158 VITON O-RING INLET FLANGE 116298-01 17 #012 VITON O-RING 3/8 BOLTS 116300-01 18 #010 VITON O-RING ¼ BOLTS SMPT-0067 19 1/2 IMPELLER RETAINING NUT - 316SS (approx. 30 ft-lb use impact gun) 92033 20 IMPELLER SHAFT 316SS 116299-01 21 DOUBLE SEAL 1 VITON, CERAMIC S-3565-V 22 SHAFT CLAMP S-3607S 23 ENGINE ADAPTER S-3556 24 TEFLON RING 116246-01 25 3/8-16 FLANGED NUT (10 ft-lb max. for re-assembly) 91077 26 3/8-16 X 3 LG. FLANGED BOLT, 316SS 116291-01 27 1/4-20 FLANGED NUT (5 ft-lb max. for re-assembly) 92017 28 1/4-20 X 2 LG. FLANGED BOLT, 316SS 116292-01 29 IMPELLER WASHER - 316SS 93044 30 PTFE REAR IMPELLER SHIM 116441-01 31 SHAFT INSTALLATION TOOL 116301-01 32 5/8 IMPELLER INSERT NUT 316SS 116470-01 2018 CDS-John Blue Co. 5

Available Electric Motors and Gas Engine: Part Number Description C-5962 / C-5960 5HP ELECTRIC MOTOR, DRIP-PROOF (3PH / 1PH) C-5963 / C-5961 5HP ELECTRIC MOTOR, TEFC (3PH / 1PH) 113798-01 5.5 HP HONDA GX-160 GAS ENGINE, ROPE START 116419-01 6.0 HP HONDA GX-200 GAS ENGINE, ROPE START Troubleshooting: ISSUE Pump makes rattling noise while running Interference observed between impeller and scroll plate Reduced pump output or pressure PROBABLE CAUSE Cavitation or pump starvation (suction lift is too high or the inlet line is too restrictive) Pump was not installed properly using installation tool and the shaft is inserted too far into the pump. Clogged impeller or inlet piping (including strainer) Leaks in suction line or at inlet gasket Collapsed suction line Trapped air in sections of suction line Suction lift is too great Discharge lift is too great Worn or damaged parts (impeller or volute) Pump fails to prime or slow prime Leaks in suction line or at inlet gasket Failure to pre-fill pump with fluid to generate suction Suction lift is too great Collapsed suction line User may need to swap the inlet flange orientation (change from center inlet to high inlet without flap) Seal reservoir fluid changes level Leak at the input shaft seal if level is low Leak at the impeller side seal if level is high 2018 CDS-John Blue Co. 6

NOTES 2018 CDS-John Blue Co. 7

LIMITED WARRANTY THIS WARRANTY IS IN LIEU OF ALL OTHER WRITTEN OR EXPRESS WARRANTIES AND REPRESENTATIONS. ANY IMPLIED WARRANTIES INCLUDING MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE ARE EXPRESSLY LIMITED TO THIS WRITTEN WARRANTY. CDS-JOHN BLUE COMPANY SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES. Use of this product for any purpose other than its original intent, abuse of the product, and/or any modification to the original product is strictly prohibited by the manufacturer, CDS-John Blue Company. Any modification to the product should be approved by CDS-John Blue Company prior to use. CDS-John Blue Company will deny Warranty claims and liability in any situation involving misuse, abuse or modification. Each new machine or component manufactured by CDS-John Blue Company through original buyer is warranted by CDS-John Blue Company to buyer and to any party or parties to whom buyer may resell, lease or lend the equipment to be free from defects in material and workmanship under normal use and service. This obligation of CDS-John Blue Company under this warranty is limited to the repair or replacement of defective parts or correction of improper workmanship of any parts of such equipment which shall within one year from the date of CDS-John Blue s original delivery thereof, be returned to CDS-John Blue s factory, transportation charges prepaid and which CDS- John Blue Company shall determine to its satisfaction upon examination thereof to have been thus defective. When it is impractical to return the defective parts of such equipment to CDS-John Blue s factory, then CDS-John Blue shall have no liability for the labor cost involved in repairing or replacing any such parts and shall be liable solely for supplying the material necessary to replace or repair the defective parts, provided that prior thereto CDS-John Blue Company shall have determined to its satisfaction that any such parts are thus defective. This warranty shall not apply to any equipment which shall have been repaired or altered outside CDS-John Blue s factory in any way so as to affect its durability, nor which has been subjected to misuse, abuse, negligence or accident, or operated in any manner other than in accordance with operating instructions provided by CDS-John Blue Company. This warranty does not extend to repairs made necessary by the use of inferior or unsuitable parts or accessories, or parts or accessories not recommended by CDS-John Blue Company. CDS-John Blue Company makes no warranties in respect to parts, accessories or components not manufactured by CDS-John Blue Company, same ordinarily being warranted separately by their respective manufacturers. DIVISION OF ADVANCED SYSTEMS TECHNOLOGIES HUNTSVILLE, AL (256) 721-9090 CDS-John Blue Company Division of Advanced Systems Technology 165 Electronics Blvd., Huntsville AL 35824 Telephone: (256) 721-9090 Fax (256)-721-9091 Toll Free 1-800-253-2583 www.cds-johnblue.com YOUR LOCAL DEALER 2018 CDS-John Blue Co. 8