Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

Similar documents
Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

Features and Benefits

MGE Galaxy 5500 Marine

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Symmetra PX 96/160. Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers

Symmetra PX 100 kw. Scalable from 10 kw to 100 kw Modular, scalable, high-efficiency power protection for data centers

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

Features and Benefits

SecureUPS On-Line 120V AC Output, 1300VA

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Galaxy VX. 380 V, 400 V, 415, and 440 V UPS System Technical Specifications 12/

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

D Series: UPS UPTO - 300KVA - Three / Three Phase

DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS. The most energy-lean UPS on the market

PowerValue 11/31 T kva

Galaxy VX. 480 V UPS System Technical Specifications 07/

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Est FlexiPower Mini UPS FPX Mini kVA

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Symmetra PX. Symmetra PX250/500kW Scalable from 25kW to 500kW Parallel-capable up to 2000kW

Liebert. FP 50Z kva

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TECHNICAL DATA SHEET KVA UPS Systemss

MGE TM Galaxy TM 7000 GFC

EFFEKTA Power Supplies

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Industrial PFC UPS System

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

S2000 PRODUCT RANGE. Ultra compact

MGE TM Galaxy TM 7000

G9000 UNINTERRUPTIBLE POWER SYSTEMS

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Huawei Network Energy, Powering the Future. Huawei UPS Solutions HUAWEI TECHNOLOGIES CO., LTD.

Modular three-phase UPS system. DPA UPScale RI kw The modular UPS for customized solutions

Green Power 2.0 MASTERYS GP

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

G9000 UNINTERRUPTIBLE POWER SYSTEMS

DPA UPScale RI kw The modular UPS for customized solutions

Technical data sheets

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Options & service. Additional 9355 options. Proven warranty and support services. Extensive service options for enhanced reliability.

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

UPS5000-E (25-75 kva) Series

POWER kva

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

Enterprise Power Protection

MASTERYS IP+ 10 to 80 kva

MKN-DSP SERIES - THREE PHASE

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

60 to 160 kva.

POWER kva

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Technical data sheets

Model ES VA to VA SINGLE PHASE UNINTERRUPTIBLE POWER SYSTEM

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Greater reliability and flexibility for large solar installations. Conext Core XC-NA series central inverters

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

On-line, Single Phase, Double Conversion UPS

Smart-UPS On-Line Lithium-ion UPS 230V

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Series 120/120VAC Universal Tower/Rack Mount

UPS Multi Power 1-28 x 42 kw up to 1MW

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

ABB central inverters ULTRA-750/1100/ kW to 1560kW

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

3ph UPS NS3000 series kVA

Up to 98% efficient under full load Similar runtimes to the previous 3u model

1.1 GENERAL CHARACTERISTICS

Uninterruptible Power Supplies

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Data Sheets

Power+ CLASSIC. 20/30 kva, 3x208 Vac

TLE Series UPS 400/500 kw With eboost Technology

Technical Data Sheets

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

APC by Schneider Electric MGE GALAXY 5500 Uninterruptible Power Supply Guide Specifications 20 kva to 120 kva Single UPS, three-phase

Transcription:

Galaxy VM From 160 kva to 1000 kva Three-phase power protection Galaxy VM trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase power protection that seamlessly integrates into the electrical, physical, and monitoring environments of customers' medium data centers, industrial, or facilities applications Very high efficiency with multimode energy management including ECOnversion TM technology even at very low load levels Robust mechanical design with fully isolated input/output cabinet Flexible battery solutions Seven-inch, color touch-screen display with a separate mimic diagram schneider-electric.com/us

Features and benefits Highly efficient, easy-to-deploy, three-phase power protection that seamlessly integrates into electrical, physical, and monitoring environments The Galaxy VM is a key component of the fully integrated and comprehensive Schneider Electric energy management solution for data centers and industrial applications. Deploying the latest in technology, it lowers efficiency and an ECOnversion mode. State-of-the-art electrical performance options, such as wide input voltage range, high overload and short-circuit capacities, and integrated backfeed protection, allow the Galaxy VM to seamlessly integrate into your electrical network to provide excellent power quality. Highly compact, the Galaxy VM also integrates well with facility monitoring systems requirements, offering energy storage flexibility that tailors the solution to your specific needs. It features top and bottom cable entry, full front service access, back-to-the-wall installation, and includes start-up services, making the Galaxy VM one of the easiest UPS units in its class to deploy, install, and maintain. Galaxy VM Integration Schneider Electric StruxureWare software applications and suites Electrical network earthing systems Facilities infrastructure Seismic certified Monitoring systems BMS, modbus, etc. Energy and cost savings ECOnversion mode High-efficiency double conversion mode ECO mode Energy storage flexibility Traditional (VRLA) and modular battery offer Common battery available in standard Short and long backup times Selectable charging modes Ease of installation System designed for ease of cabling in confined installation spaces Single cabinet top and bottom cable entry Integrated casters for ease of mobility on UPS and modular battery cabinets 2 Galaxy VM

Galaxy VM features Integration into your electrical network Wide input voltage and frequency ranges Genset compliant with adaptive ramp-in Integrated parallel capability up to five UPS units Built-in integrated and tested backfeed protection Full integration with Schneider Electric solutions Fully integrates into the comprehensive Schneider Electric energy management solution for data centers and industrial applications Smart Power Test Ability to to test the UPS at full load without the need to rent a load bank and before bringing customers load on line AC Bypass AC Normal AC Normal AC Normal AC Normal AC Normal Load Distributed parallel connection for increased power and redundancy Integration into your facility infrastructure Compact footprint Back-to-the-wall installation Operates at 40 o C continuously without de-rating Embedded seismic certified to OSHPD, IBC2012 and CBC2013 to Sds=2.02g Low audible noise levels Replaceable dust filter for harsh environments Configurable input/output relays Top and bottom cable entry Parallel capability to increase multiple UPS systems for capacity or redundancy Ability to add UPS's in a parallel configuration without the need to transfer the load to bypass Cold Start: capability to start the UPS on battery without mains power present External synchronization capability 3 Galaxy VM

Galaxy VM features High-efficiency operating modes: ECOnversion mode Ultra high efficiency up to 99% Keeps excellent load protection Continuously charged batteries Double conversion mode Up to 96.5% efficiency in double conversion online mode even at low load levels Less energy losses = cost savings Less heat dissipation = lower cooling needed and hence cost savings Compliant with IEC 62040-3 class 1 output voltage of UPS standard Input power factor correction and no harmonics ECO mode Up to 99.5% efficiency Compliant with IEC 62040-3 class 3 output definition of UPS standard ECOnversion mode Enables control of input current to almost same quality as known from on-line UPS AC in Bypass Switch ~ ~ PFC Recfifier = == = DC/DC + + Battery Inverter Load Galaxy VM ECOnversion meets Class 1 of IEC 62040-3: zero break transfer during power outage Nominal Value (Voltage %) 100% 80% 60% 40% 20% 0% -20% -40% -60% -80% ECOnversion -100% 0.1 1 10 100 Transient duration in milliseconds (ms) Over voltage transient limit Under voltage transient limit 1,000 +10% -10% Cost savings by using Galaxy VM: Very high efficiency for small to medium data centers, buildings, and facilities At 100% load Alternate UPS Alternate UPS Alternate UPS Efficiency 95% 94% 93% Savings by using Galaxy VM/ year (in ECOnversion mode) Ten-year savings by using Galaxy VM (in ECOnversion mode) 23,700 29,625 35,550 237,000 296,250 355,500 Considering a total UPS load of 720 kw (4 x 200 kva running at 100 percent load). At the national average rate of 0.07/kWh, a 720 kw Galaxy VM installation running in ECOnversion mode (99% efficiency) can save 296,250 for 10 years compared to a 720 kw UPS with 94 percent * In the same scenario, a Galaxy VM operating in double conversion mode (> 96.5% efficiency) has cost savings equal to 130,350 over five years compared to a 720 kw UPS with 94 percent *Figures calculated using APC by Schneider Electric UPS efficiency comparison calculator are estimates. Individual savings could vary. 4 Galaxy VM

Galaxy VM features Advanced individual battery string monitoring for both current and voltage Energy storage options Modular battery cabinets Traditional (VRLA) battery offer: --Choice of multiple runtime options and battery cabinet configurations --Each cabinet has only one battery string with its own DC breaker and slide out shelves that are designed for ease of use Modular battery offer: --Ease of scaling in smaller increments provides customizable backup time or redundancy --Advanced string monitoring of current and voltage impedance allows for predictive information of the batteries --Battery replacement without the need to go to bypass keeps the load protected Matching wall mounted battery breaker box and battery breaker kits as well as empty battery cabinets are available Classical battery cabinet : seismic IBC level 2 with battery disconnect at string level Parallel UPS configurations can be connected to a common battery without the need for a battery coupling cabinet reducing footprint and increasing cost savings Flywheel & Lithium Ion compatibility Wall-mounted battery breaker box 5 Galaxy VM

Galaxy VM features LCD display From ordering to installation, the Galaxy VM makes your solution choice easy: Start-up 5 x 8 start-up services are included, allowing for full coverage of factory warranty Remote monitoring service included for first year Installation Casters allow UPS configurations to be moved easily and installed up against the wall Separate I/O cabinet for input and output cabling ensures quick/error free and easy installation Power cabinet UPS Galaxy VM management card compatibility chart I/O cabinet Top and bottom cable entry standard provides great flexibility to the installer Monitoring 7-inch, color touch-screen display Integrated network management capability for easy access to the network Integrated battery monitoring capability included for modular battery offer Modbus (SCADA and ION-E) capability Customizable dry contacts and relays SKU/Part number Description Protocol supported Included with Galaxy VM AP9635CH AP9631 One plug: Ethernet SNMP (similar to AP9630) One plug: RS485 modbus RTU 6 configurable dry contacts IN 10 configurable dry contacts OUT 2 free slots for optional communication cards UPS Network Management Card 2 w/ Environmental Monitoring up to 1 sensor, out-of-band access, and modbus capabilities Remote monitoring and control of an individual ups by connecting it directly to the network card also has environmental monitoring for up to 2 sensors HTTP, HTTPS, IPv4, IPv6, NTP, SMTP, SNMP v1, SNMP v3, SSH V1, SSH V2, SSL, TCP/IP, Telnet and MODBUS RTU Optional com cards : AP9635CH, AP9631, AP9630 HTTP, HTTPS, IPv4, IPv6, NTP, SMTP, SNMP v1, SNMP v3, SSH V1, SSH V2, SSL, TCP/IP, Telnet, MODBUS RTU, MODBUS TCP/IP HTTP, HTTPS, IPv4, IPv6, NTP, SMTP, SNMP v1, SNMP v2c, SNMP v3, SSH V1, SSH V2, SSL, TCP/ IP, Telnet AP9630 Remote monitoring and control of an individual UPS by connecting it directly to the network HTTP, HTTPS, IPv4, IPv6, NTP, SMTP, SNMP v1, SNMP v3, SSH V1, SSH V2, SSL, TCP/IP, Telnet 6 Galaxy VM

StruxureWare for Data Centers software suite In the data center environment, our Galaxy VM is fully managed through StruxureWare for Data Centers software, an integrated suite of data center infrastructure management applications. It enables businesses to prosper by managing their data centers across multiple domains, providing actionable intelligence for an ideal balance of high availability and peak efficiency throughout the entire data center life cycle. StruxureWare software applications and suites are key elements of Schneider Electric EcoStruxure integrated hardware and software system architecture a system designed for intelligent energy management. A comprehensive portfolio of services Schneider Electric Critical Power & Cooling Services provides the expertise, services, and support you need for your building, industry, power, or data center infrastructure. Our world-class life cycle services offer a smart way to install and maintain your critical applications, ensuring your systems are always running at peak performance. Assembly and start-up service by a certified Field Service Engineer (FSE) allows full factory warranty coverage. A Schneider Electric-certified installation makes certain your equipment is properly configured for optimal performance. This service features a standard eight-hour, five-day response time, with upgrades available for off-business hours. On-site warranty extension service In the case of a system event, an FSE will arrive by the next business day (or faster with upgrades) to isolate, diagnose, and correct in as little time as possible, minimizing downtime. Advantage plans Flexible service packages offer smooth system maintenance to improve uptime at a predictable cost. The Advantage Plus, Prime, Ultra, and Max are full-service packages that include technical support, preventive maintenance, quick on-site response, and remote monitoring. Response time upgrades are available. Remote monitoring service (RMS) RMS is an economical and easy-to-use Web-based service that lets you quickly respond to environmental or system changes. Trained technicians provide secure 24-hour monitoring of your physical infrastructure to diagnose and resolve events before they become critical. Preventive maintenance Preventive maintenance on-site examinations keep your critical systems running at maximum 7 Galaxy VM

Technical specifications Rated power ( kva/kw ) 160/144 200/180 320/288 400/360 480/432 600/540 640/576 800/720 1000/900 Normal AC supply input Input voltage (V) 250 600 V 1 Normal and bypass AC inputs Frequency (Hz) Single input or dual input as standard 40 70 Hz Input power factor 0.99 THDI < 3% full load Bypass AC input Input voltage range 342 457 V Frequency 50 Hz or 60 Hz Output Phase-to-phase output voltage (V) Load power factor Output frequency Overload capacity utility operation at 40 C 380/400/415 V 0.9 (0.7 leading to 0.5 lagging without de-rating) 50/60 Hz +/- 0.1% (free-running) 150% for 1 minute and 125% for 10 minutes Output voltage regulation +/- 1% Total harmonic distortion (THDU) Output voltage tolerance < 2% at 100% linear load; < 3% at 100% non-linear load Symmetric load (0 100%): +/- 1% static; asymmetric load: +/- 3% static Overall efficiency ECOnversion mode (meets EN62040-3 Class 1) Up to 99% (meets EN62040-3 Class 1) Efficiency at full load (AC-AC) at 100% load Up to 96.5% Standard ECO mode Up to 99% Communication and management Control panel Multifunction 7" touch-screen color LCD display with built-in NMC, modbus (SCADA and ION-E), two empty NMC card slots Dimensions and weights UPS (H x W x D) mm 1970 x 1052 x 854 1970 x 2104 x 854 1970 x 3156 x 854 1970 x 4208 x 854 1970 x 5260 x 854 Weight in kg. (UPS) (total -power cabinet plus I/O cabinet) 699 724 1398 1448 2097 2172 2796 2896 3620 Regulatory Safety IEC 62040-1 EMC/EMI/RFI IEC 62040-2 Markings CE,C-Tick Performance IEC 62040-3, VFI -SS -111 Transportation ISTA 2B Seismic zone IBC Level 2:2006 Environmental Operating temperature 0 C 40 C 2 Storage temperature Relative humidity Operating elevation -25 C to 55 C without batteries -15 C to 40 C with batteries 0% 95% non-condensing 1,000 m. at 100% load Storage elevation 0 15,000 m. Max. audible noise at 1 m from unit 55 db at 70% load, 65 db at 100% load 1 Input voltage = (320 V to Nominal V +20%) for full load. (Nominal V+20% up to 600 V) for 1 min for full load. (250 V 320 V) load dependant. 2 For ambient operating temperature from 40 C to 50 C (104 F to 122 F), derate the load with 2.5 percent per 1 C (2.5 per 1.8 F). 2015 Schneider Electric. All Rights Reserved. Schneider Electric, ECOnversion, Galaxy, StruxureWare, APC, and EcoStruxure are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are the property of their respective owners. www.schneider-electric.com 998-1203811_50hz_IEC