SMT-BM 20 A BMM 05 F BMM 05 AF

Similar documents
Braking resistor. Braking resistor types for Infranor drives.

CD3000S-1PH Thyristor Unit Heater Break version

APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

CD3000S-1PH Thyristor Unit Analog Input version

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

Features. Description. Table of Contents

LS200 Series Instruction Manual

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Thyristor power units TC3000. Three-phase load control. User Manual

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Applications DC Motors Stepping and Servos Solenoid Valves Relays Lamps and Signal Systems Input to On-Board Regulators Some Floppy Disc Drives.

Installation Instructions. Y-Series Brushless Servo Motor

Specification of Battery Charger

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Installation Instructions

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Switching DC Power Supply

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Brake Chopper BC BC 4.1. Instruction and Operation Manual

Electronic circuit breaker EBU10-T

GTS 15/25/40/50/60/75/90/120A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

The 3 kw Models will accept 200*/230 VAC single phase and 200*/208 VAC three phase input power.

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Silvertel. Ag Features. 2. Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL and SMT package available

8. Filter / Autoranging Rectifier Module (FARM )

DC POWER SUPPLY SYSTEMS

GTS-L4 5 / 10 / 15 TECHNICAL DATA

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Features IN THIS CHAPTER

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

AFM500X Automatic Flashing Module

50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Technical Documentation

3.5 Amp Bi-polar stepper motor drive MSE570 Evo 2

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

AC/DC Converter MBP250-2A13D13M

Electronic Circuit Breaker ESS20-0..

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Unidrive M700 Class leading performance with onboard real-time Ethernet

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

Yaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0.

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Mclennan Servo Supplies Ltd. Bipolar Stepper Motor Translator User Handbook PM546

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

SINUS K 13. ACCESSORIES Braking resistors APPLICATION TABLES 78/160 INSTALLATION INSTRUCTIONS

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

DKG-114 MANUAL AND REMOTE START UNIT

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Testing Energy Storage Systems: From EVs to Utility Grid

The High Power Stack Horizon

GTS-L 5 / 10 / 15 POWER SOLID STATE RELAYS WITH LOGIC CONTROL TECHNICAL DATA

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

ABB Softstarter Benefits Charnchanok Thongprad

Silvertel. Ag Features. 2. Description. Power-Over-Ethernet Module for CCTV. IEEE802.3af compliant

Lexium integrated drives

Low and High Voltage Power Supplies

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

SAX Electronic Valve Actuator

ZWD225PAF Series Instruction Manual

8BVE0500HW General information. 2 Order data 8BVE0500HW

HIB Enclosed Inverter User Guide

SAX Electronic Valve Actuator

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Emergency lighting units EM converterled

Industrial Power Supplies

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

AGV5-1, AGV5-2 FORM AGV5 OM 11-02

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Emergency lighting units EM converterled

Transcription:

gb SMT-BM 20 A BMM 05 F BMM 05 AF SINGLE-AXIS RACKS 1

2 SINGLE-AXIS RACKS

This is a general manual describing a series of racks receiving servo amplifiers having output capability suitable for driving AC brushless sinusoidal servo motors. This manual may be used in conjunction with appropriate and referenced drawings pertaining to the various specific models. Maintenance procedures should be attempted by highly skilled technicians (EN 60204.1 standard) using proper test equipment. The conformity with the standards and the "CE" certification are only valid if the items are installed according to the recommendations of the racks and amplifiers manuals. Any contact with electrical parts even after power down may involve physical damage to equipment or people. Wait for min. 30 seconds after power down before handling the rack or the amplifiers (residual voltage). INFRANOR does not assume any responsibility for any physical or material damage due to improper handling or wrong descriptions of the ordered items. INFRANOR reserves the right to change any information contained in this manual without notice. This manual is a translation of the original document and does not commit INFRANOR's responsibility. The french manual is the only reference document. INFRANOR September 1999. All rights reserved Issue: 3.0 SINGLE-AXIS RACKS 3

4 SINGLE-AXIS RACKS

Contents CONTENTS...5 CHAPTER 1 GENERAL DESCRIPTION...7 1 - CONFORMITY WITH EUROPEAN STANDARDS: "CE" APPROVAL...7 1.1 - Introduction...7 1.2 Standards compliance...8 1.3 Affixing of the «CE» label : 1995...8 CHAPTER 2 SMT-BM 20 A...9 1 SPECIFICATIONS...9 1.1 Main technical datas...9 1.2 Braking resistor...9 1.3 Dimensions of the external protected resistor: «dp» housing...9 1.4 Dimensions of the SMT-BM 20 A single-axis rack...10 1.5 Current ratings depending on the various fan types of the SMT-BM 20 A single-axis rack...10 1.6 SMT-BM 20 A rack types...11 2 CONNECTION DIAGRAMS...12 2.1 Diagram of the three-phase mains connection via a 400/230 autotransformer with auxiliary supply...12 2.2 SMT-BM 20 A connections...13 2.3 230 Vac single-phase connection diagram...14 CHAPTER 3 BMM 05 F BMM 05 AF...15 1 ELECTRICAL SPECIFICATIONS...15 2 INPUTS-OUTPUTS...15 3 DIMENSIONS...16 4 RACK TYPES...17 5 BMM 05 F...17 5.1 Diagram of the connector to the 230 Vac single-phase mains...17 5.2 Connections...18 6 BMM 05 AF...18 6.1 Diagram of the connection to the 230 Vac single-phase mains...18 6.2 Connections...19 7 CONFIGURATION...19 APPENDIX...20 Contents 5

6 SINGLE-AXIS RACKS

Chapter 1 General description 1 - CONFORMITY WITH EUROPEAN STANDARDS: "CE" APPROVAL 1.1 - Introduction The SMT-BM 20 A BMM 05 F and BMM 05 AF single-axis racks allow a large integration of the power supply the auxiliary supply the braking system and the mains filter while keeping the principle of the pluggable "B" series amplifiers. Their use is especially recommended for decentralized axes; this often concerns axes connected via a field bus (CAN PROFIBUS etc.) as well as applications with a positioner ("m" version of the SMT-BD1 amplifier). The amplifier current ratings of both SMT-BD1 and SMTB.Si-2Tz series in 220 V used with the SMT-BM 20 A single-axis rack are between 4 A and 60 A peak. The 70 A and 100 A amplifiers can only run in a single-axis rack because of their dimensions. This also concerns the 400 V amplifier range. The BMM 05 F or BMM 05 AF rack is only to be used with amplifiers equipped with the option "w" (braking system integrated in the amplifiers for their use in single-axis racks). The BMM 05 F or BMM 05 AF rack is used with amplifier types with current rating 17 A. The capacity of the mains filter is limited at 5 Arms. This manual must be used in conjunction with the standard manuals of the SMTB.Si-2Tz and SMT-BD1 amplifiers with 220 V input. It describes the specifications and the commissioning: - of the SMT-BM20 A standard version and its various accessories: mains filter fan - of the low voltage BMM05 F or BMM 05 AF version including the mains filter and which allows the control of a brake on the motor. This is useful for decentralized applications. The SMT-BM 20 A single-axis rack is supplied: - by the 230 VAC three-phase mains - via an isolated 400/230 VAC transformer - or via a 400/230 VAC autotransformer. It is possible to have a 230 VAC single-phase mains supply (with a cheaper wiring than the three-phase supply) but it must be kept for low power applications. The three-phase supply should be preferred for average application currents that exceed 10 A (in order to limit voltage ripples). An internal device in the SMT-BM 20 A limits the inrush current at power on. The BMM 05 F or BMM 05 AF single-axis rack can only receive a single-phase supply: - via the 220 VAC single-phase mains - via an isolated 380/220 VAC transformer - or via a 380/220 VAC auto-transformer. An internal device serially mounted with the power lines allows to limit the inrush current at power on. The SMT-BM 20 A standard version compliance with the CE recommendations requires a mains filter that must be mounted between the voltage source and the rack. The recommended filters are: - filter FN612-20/06 for a single-phase voltage - filter FN356-16/06 for a three-phase voltage. Note: the BMM 05F or BMM 05 AF version includes this filter. Chapter 1 General description 7

NOTE The braking system protective function - in case of energy rejection by the motor on the DC power supply - is controlled by the amplifier and not by the single-axis rack. The protected resistor "w" is described in this manual with regard to its use in single-axis applications. CAUTION The connection diagrams must be carefully followed especially when using the auxiliary supply in order to keep the position information. The earthing of the BM20 A housing is MANDATORY in order to ensure the users' physical safety in case of isolation failure to the mains. INFRANOR will withdraw its warranty on all items that do not meet this requirement. 1.2 Standards compliance The "B" series amplifiers mounted in the single-axis rack with mains filter BF35 have been approved for their conformity to the Electromagnetic Compatibility standards: - EN55011 group 1 class A regarding radioelectrical disturbances - CEI 801-2 - 3-4 regarding immunity. The conditions and results of the tests made by the official LCIE laboratory (Laboratoire Central des Industries Electriques) approved by the European Community are recorded under n 416040 416041 416042 and 416043. The test results according to the Low Voltage Directive are recorded in the LCIE report n 413777. Standard to be applied for electrical equipments of industrial machines: EN 60204-1. 1.3 Affixing of the «CE» label : 1995 8 Chapter 1 General description

Chapter 2 SMT-BM 20 A 1 SPECIFICATIONS 1.1 Main technical datas Rated input power voltage 230 Vac three-phase +10% / -15% Rated input auxiliary voltage 230 Vac single-phase +10% / -15% Minimum auxiliary voltage 100 Vac single-phase Continuous rated current on DC bus 28 Adc Rated RMS current on the motor 20 Arms Peak current on DC bus (5% of the time) 60 A 1.2 Braking resistor The braking resistor is depending on the current rating of the amplifier plugged in the single-axis rack. AMPLIFIER TYPE BRAKING RESISTOR VALUE RATED POWER PEAK POWER BRAKING RESISTOR TYPE BRAKING RESISTOR HOUSING TYPE 220/04 100 Ω 100 W 16 KW RSSD 20 x 117 dp 100/100 220/08 220/12 220/17 220/30 2 x 100 Ω en 200 W 32 KW RSSD 20 x 117 dp 50/200 parallel mounted 220/45 220/60 15 Ω 280 W 10 KW RSSD 30 x 250 dp 15/280 1.3 Dimensions of the external protected resistor: «dp» housing A B 52 40 83 7 7 AMPLIFIER TYPE 220/04 to 220/30 220/45 and 220/60 Dimension A 157 290 Dimension B 145 278 Chapter 2 SMT-BM 20 A 9

1.4 Dimensions of the SMT-BM 20 A single-axis rack 312 290 Fan 278 Heatsink 7 95 67 40 7 290 XM 1234 XA2 UVW 123 XA1 87 105 105 105 105 M 6 278 CONNECTION UPPER VIEW 40 SPACE BETWEEN THE AMPLIFIERS 1.5 Current ratings depending on the various fan types of the SMT-BM 20 A single-axis rack TYPE Urated (Vrms) Imax (Arms) 1 s Irated(Arms) Without fan With fan SMT-BD1 and SMTB.Si-220/04 230 4 2 SMT-BD1 and SMTB.Si-220/08 230 8 4 SMT-BD1 and SMTB.Si-220/12 230 13 6 SMT-BD1 and SMTB.Si-220/17 230 17 85 SMT-BD1 and SMTB.Si-220/30 230 29 10 12 SMT-BD1 and SMTB.Si-220/30r 230 29 10 15 SMT-BD1 and SMTB.Si-220/45 230 46 10 15 SMT-BD1 and SMTB.Si-220/45r 230 46 10 20 SMT-BD1 and SMTB.Si-220/60 230 58 10 19 SMT-BD1 and SMTB.Si-220/60r 230 58 12 20 NOTE: This table replaces the equivalent table mentioned in the amplifier manuals that corresponds to the use in multiaxes racks. 10 Chapter 2 SMT-BM 20 A

1.6 SMT-BM 20 A rack types SMT - B M 20 A V «B» series Single axis 20 Arated Auxiliary supply Fan Chapter 2 SMT-BM 20 A 11

2 CONNECTION DIAGRAMS 2.1 Diagram of the three-phase mains connection via a 400/230 autotransformer with auxiliary supply The auxiliary supply input can be wired between two 230 V phases at the autotransformer output. It can also be directly connected to the 230 V mains between phase and neutral. K K.1 L1 L2 L3 N 400 K1 24 V 230 Autotransformer Aux. Logic ON Amp. ready ENABLE ON Amplifier ON (***) (**) Aux. Logic OFF Aux. OFF Aux. Amplifier OFF Enable Idyn IN OUT FILTER Fan Enable Motor brake XA1 L1 L2 L3 1 2 3 XA2 Aux 1 2 3 4! This diagram complies with the "JK" jumper on the amplifiers ENABLE Amp. Ready Idyn(*) 20 23 18 19 8 9 SMT-BM 20 A AMPLIFIER SMT-BD1/I or SMTB.Si/I U V W XM! Chassis grounding 4 cables + shield MOTOR X1 RES 6 pair shielded cables (+thermal probe) (*) Motor brake spool control on versions SMT-BD1/f SMT-BD1/h and SMT-BD1/m (**) 3 A single-phase circuit breaker curve C. (***) 12 A (20 A max.) circuit breaker curve C. IMPORTANT The use of an autotransformer does not allow any isolation between the mains and power stage (and consequently motor). So it is MANDATORY to mount a correctly sized circuit-breaker in case of a short-circuit inside the single-axis rack (rectifier bridge power bridge motor). The information AMP. READY (pins 18-19 of X4) must be used to open the Relay when a fault occurs. 12 Chapter 2 SMT-BM 20 A

2.2 SMT-BM 20 A connections Optional fan 230 Vaux. supply and/or fan 1 2 3 4 Aux. (*) XA2 (**) K M O T O R F35 FILTER 1 2 3 1 2 3 U V W L1 L2 L3 H Z Mains filter FN356-16/06 Transformer or autotransformer 400/230 VAC 3 phases R S T K1 RD XM XA1 MOTOR POWER 3 x 230 VAC Braking resistor AMPLIFIER (*) 3 A single-phase circuit breaker curve C (**) 12 A (20 A max.) circuit breaker curve C MOTOR SHIELD CONNECTION OVER 360 U V W Earth Chapter 2 SMT-BM 20 A 13

2.3 230 Vac single-phase connection diagram This solution is only possible if the power and auxiliary supplies are single-phase connected to 230 VAC (phase/neutral). But the maximum RMS current must not exceed 10 Arms. 1 ph. filter Ref: FN612-20/06 N 1 SMT-BM 20 A (**) L1 AMPLIFIER 230 VAC 230 VAC L2 310 VDC power Aux. L3 3 ph. bridge (*) 230 VAC aux. supply 1 ph. bridge 310 VDC logic U M V W (*) Single-phase 3 A circuit-breaker curve C (**) Single-phase 20 A circuit-breaker curve C 14 Chapter 2 SMT-BM 20 A

Chapter 3 BMM 05 F BMM 05 AF 1 ELECTRICAL SPECIFICATIONS Rated auxiliary supply voltage 230 Vac single-phase +10% / -15% Maximum auxiliary supply voltage 230 Vac +10% Minimum auxiliary supply voltage 100 Vac Rated power voltage 230 Vac single-phase +10% / -15% Maximum power voltage 230 Vac +10% Minimum power voltage 100 Vac Continuous RMS rated current on the motor 05 Arms RMS peak current on the motor 17 Arms Rated input voltage of the brake supply 24 Vdc +/-10% Maximum output current of the brake control 2 A Maximum output power of the brake control 30 W Minimum closing voltage 20 Vdc Relay response time at the closing 4 ms Relay response time at the opening 2 ms Estimated number of opening/closing 10exp7 Main rejection filter (integrated in the module) Braking resistor (see chapter 2 section 1.2) dp 100/100 2 INPUTS-OUTPUTS XA1 CONNECTOR XA1.1 : 0 V (24 V) supply XA1.2 : 24 Vdc supply and brake spool (+) XA1.3 : Brake spool (-) XA2 CONNECTOR (BMM 05 AF ONLY) XA2.1 : 230 Vac single-phase auxiliary supply. XA2.2 : 230 Vac single-phase auxiliary supply. XA3 CONNECTOR XA3.1 : 230 Vac single-phase power supply. XA3.2 : 230 Vac single-phase power supply. XM CONNECTOR XM1 : Motor U phase. XM2 : Motor V phase. XM3 : Motor W phase. GROUND SCREW: ground potential reference. Chapter 3 BMM 05 F BMM 05 AF 15

NOTE The XA2 connector of the auxiliary supply is only available on the BMM 05 AF version. On the BMM 05 F version the auxiliary supply is factory wired inside the rack from the power supply (XA3). 3 DIMENSIONS Same dimensions as the SMT-BM 20 A. The single-phase mains filter is mounted at the bottom of the module 312 290 Fan 278 Heatsink 7 95 67 7 290 40 105 105 105 87 XM 1234 XA2 UVW 123 1 2 BMM 05 AF UPPER VIEW CONNECTION XA1 XA3 Single-axis filter SPACE BETWEEN THE AMPLIFIERS DOWN VIEW CONNECTION 16 Chapter 3 BMM 05 F BMM 05 AF

4 RACK TYPES B M M 05 A F «B» series Single axis Single phase Rated current With XA2 auxiliary supply connector Integrated mains filter 5 BMM 05 F 5.1 Diagram of the connector to the 230 Vac single-phase mains N 1 XA3 1 F IL 1-phase AMPLIFIER 230 VAC 230 VAC 2 T E R 310 VDC power supply Single-phase 5 A circuit-breaker curve C bridge 1-phase XM U 310 VDC aux. supply M V bridge W XA1 1 24 V 1 AT 2 3 Idyn OK Brake Chapter 3 BMM 05 F BMM 05 AF 17

5.2 Connections 24 VDC M O T O 24 VDC (brake) K1 R RD Braking resistor AMPLIFIER 1 2 3 1 2 3 U V W XM MOTOR XA3 1 2 O +F F XA1 1 AT Motor brake K 230 V 1-phase K1 Amp. ready ON OFF Enable Amplifier ON Amplifier OFF Enable 6 BMM 05 AF 6.1 Diagram of the connection to the 230 Vac single-phase mains N 1 (**) XA3 1 F il 1 ph.bridge AMPLIFIER 230 VAC 230 VAC 2 t e r 310 VDC power Aux. (*) XA2 1 1 ph.bridge 230 Vaux 2 310 VDC logic XM U M V W XA1 1 24 V 1 AT 2 3 Idyn OK Brake (*) 3 A single-phase circuit breaker curve C. (**) 5 A single-phase circuit breaker curve C. 18 Chapter 3 BMM 05 F BMM 05 AF

6.2 Connections 24 VDC K1 M OT O R 1 2 3 4 XA2 Aux. 24 VDC (Brake) 1 AT K 230 V 1 ph. Aux. Logic ON Amp. ready ON RD Braking resistor AMPLIFIER 1 2 3 1 2 3 U V W XM MOTOR XA3 1 2 O +F F XA1 Motor brake K1! Logic OFF Aux. This diagram complies with the JK jumper on the amplifiers OFF Aux. 7 CONFIGURATION BACKPLANE CONFIGURATION FOR THE BRAKE CONTROL The brake control can be activated by several functions of the amplifier: AMP. READY (AOK) POWER READY (POK) and IDYN READY (IDYN OK). IDYN is the only directly controlled by the processor. The AOK function includes all faults. The specific power faults are grouped on the POWER READY signal. It is possible by means of jumpers to control the brake according to the three logic amplifier status signals below. AOK + POK + IDYN OK AOK + IDYN OK IDYN OK AB + DE + FC AB + DC CA The amplifiers are delivered with configuration CA. EP EL GH AB DE FC D5 AB DC CA D6 R2 R1 R3 D4 D3 D2 D1 S R Chapter 3 BMM 05 F BMM 05 AF 19

SHIELD CONNECTION ON THE CONNECTORS Appendix RULE The shield must never be interrupted or corrupted over the whole cable length Self-sticking copper ribbon if necessary for increasing the shield diameter in order to get it correctly tightened under the clamp W V U Ground Motor connector for resolver and motor BF RACK L1 L2 U V W N The cable can be soldered on the shield because the connector box is metallic. This solution does not exactly meet the EMC requirements but it is acceptable. Motor connector box Metallic or metal plated plastic SUB-D pin package As short as possible Ground U V W X 360 shield ensured by the tightening clamp SMT.AS / M.AS UVW X INFRANOR amplifier The fastening screws must be tightened in order to ensure the shield continuity on the amplifier housing BM 20 A SUB-D connectors NOTE When the 360 shield connection is made by means of a collar it is not necessary to connect a cable on the appropriate pin of the SUB-D connector. 20 Appendix