1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Similar documents
1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Transformer bushings, type GOH. Technical guide

1ZSE en, Rev. 9. Transformer bushings, type GSA-OA Technical guide

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

Transformer bushings, type GSA-OA Technical guide

Bushings for High Voltage AC Applications

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

1ZSC ABJ EN, REV. 1. Gas insulated wall bushings type GGFL Technical guide

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

A of 3. Edition : Date : Page : Document No. Amendments :

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Transformer bushings, type GOA 250. Installation and maintenance guide

EMPAC Metal enclosed capacitor bank for wind applications

MICAFIL RIP Transformer Bushings AirRIP / RTKF kv

A of 14. Edition : Date : Page : Document No. Amendments :

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance

ZX2 Gas-insulated medium voltage switchgear

DM Condenser bushings, kV DURESCA

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Low voltage bushings for pad-mounted distribution transformers Technical information guide

MEDIUM VOLTAGE PRODUCT. KECA 80 C85 Current Sensor Instructions for installation, use and maintenance

MEDIUM VOLTAGE PRODUCT. KECA 80 D85 Current Sensor Instructions for installation, use and maintenance

DURESCA Busbar system. For indoor and outdoor applications, type DE / type DG DURESCA

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

ZX-Family Gas-insulated medium voltage switchgear

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Surge arrester POLIM-H..SD

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Surge arrester POLIM-H.. ND

Voltage limiting device HVL

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Voltage limiting device HVL

Surge arrester POLIM-C.. HD

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

kv А

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

dfdf 34.5 kv and 69 kv, Type O Plus C II Condenser Bushings Technical Guide

INSTRUCTION MANUAL CRS Combined insulation bushing

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Contact us. Catalog Low voltage generators for diesel and gas engines Industrial Marine applications - series Standard series

Electronic overload relays EF205 and EF370

LV Capacitors QCap-L series Capacitors for power factor correction

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

Current transformers. Outdoor operation SF 6 -gas insulated. JGF ( ) kv

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

Transformer Bushing Type EKTG

Medium voltage products. KEVCD A combined current and voltage sensor Instructions for installation, use and maintenance

Field Experience & Reliability Tests for the New EasyDry Condenser Bushing LUKAS MUGGLI

1ZSC AAX EN, Transformer bushing, type GSC Installation and maintenance guide

Transformer Bushing Type EKTO

en, Transformer bushing, type GSA-OA Installation and maintenance guide...

Mini contactors B6, BC6 with 3 pole

Overview Overvoltage protection

HVDC bushing without oil side porcelain Type GOF, for outdoor mounting. Installation and maintenance guide

GAS INSULATED VOLTAGE TRANSFORMERS.

PABS. AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS ANSI STANDARDS AN ALSTOM COMPANY

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

CP Automatic capacitor bank

Electronic overload relay EF65, EF96 and EF146

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R

Surge arrester POLIM-H..N

1ZSC ABE en, Rev. 1. HVDC bushing, type GSD Installation and maintenance guide

Transformer Bushings Type COT COT kv to 245 kv up to 3150 A IEC 137

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

B kv T&D GAS INSULATED SWITCHGEAR

A manufacturer s view of bushing reliability, testing and analysis. Lars Jonsson Håkan Rudegard

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector

IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector

3 TM Cold Applied Barrier Boot System

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

B kv Gas-insulated Substations

Selective main circuit breakers S 750 series Technical Data

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

Low Voltage Systems MNS and MNS is PowerCenter

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Medium Voltage Products. KEVA 24 B20; KEVA 24 B21 Voltage Sensors Instructions for installation, use and maintenance

en, Rev. 10. Transformer bushings, type GOH Installation and maintenance guide

Eaton s Cooper Power Systems

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

NXPLUS C Single busbar. Maintenance-free for lifetime

Thermal overload relay TF140DU and TF140DU-V1000

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Transcription:

1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide

Original instruction The information provided in this document is intended to be general and does not cover all possible applications. Any specific application not covered should be referred directly to ABB, or its authorized representative. We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB.

Table of contents Design 5 Standards 5 RIPCOAT 5 Features and benefits 5 Transportation and long term storage 5 Testing 7 Routine testing 7 Type tests 7 Special tests 7 Test tap 7 Electrical data 8 Dimensions 9 Connection details 12 Draw rod system 12 Fixed bottom contact 13 SF 6 side terminal 13 Standard end-shield 13 Conductor loading 14 Overloading of bushings according to IEC 14 Short-time current 14 Recommendations for positioning 15 Ordering particulars 16

TRANSFORMER BUSHINGS TYPE GSBK TECHNICAL GUIDE 5 Design 1. Outer terminal 2. Test tap 3. Mounting flange 4. RIP core 5. Center tube GSBK is a Resin Impregnated Paper (RIP) bushing intended for immersed oil SF 6 service. The bushing can be mounted in any direction from vertical to horizontal. The insulation core of the GSBK is produced by winding crepe paper onto a center tube, with aluminium foil insert for electrical stress control. The manufacturing process is optimized to give a partial discharge free bushing with low dielectric losses. As a current conductor, GSBK uses the center tube, which is moulded into the RIP core. The outer terminal is fit to the center tube by a bolted joint. The bottom contact on the transformer side is mounted by a draw rod system or by a bolted joint. 1 4 3 2 5 Standards The GSBK bushing is designed and tested according to IEC 6137 and IEC 62271-211. RIPCOAT Water uptake on the RIP bushings during transport, handling and storage leads to increased dielectric losses. At site this means that the bushings might need to be dried before assembling leading to delays. A water barrier RIPCOAT has been developed to solve this problem. The time to reach critical dissipation factor has been stretched by a factor of up to 8 by using RIPCOAT compared to bushings with an unprotected oil-side. Actual time depends highly on level of relative humidity and temperature. Features and benefits Solid Reduced risk of fire. No restriction in mounting angle. Oil leakage from the bushing eliminated. Seals the transformer Reduced risk of fire. Risk of oil leakage from the transformer reduced.. Non-brittle materials Protection of people and equipment. Easy handling. Safe transport - even when mounted on the transformer. High earthquake withstand. Light weight, compact Easy handling, small space requirements inside transformer, low life cycle environmental impact. Transportation and long term storage The bushing is surrounded by a sealed moistureproof wrapping material together with a drying agent upon delivery. The supplied protective wrapping shall not be opened if the bushings are intended to be stored. After transformer test, it is also important to reseal the bushing with the supplied protective wrapping or a similar moisture-proof wrapping, together with a drying agent. The wrapping works as protection for transportation and storage ( 6 months). Note that bushings with standard wrapping shall be stored protected from precipitation. 1 Transformer bushing type GSBK oil SF 6 connection. For longer storage times (>6 months) a container have to be ordered separately.

6 TRANSFORMER BUSHINGS TYPE GSBK TECHNICAL GUIDE Table 1. General specifications For conditions exceeding the standard specification, please consult the supplier. Application: Classification: Transformers Resin impregnated paper, capacitance graded, completely immersed bushing, temperature class E (12 C) according to IEC 6137 Ambient temperature: +4 C to -4 C, minimum value acc. to temperature class 3 of IEC 6137 Immersion medium on switchgear side: Max pressure of medium on switchgear side: Immersion medium on transformer side: Oil level in transformer: Max. pressure of medium: Angle of mounting: SF 6 gas. Max daily mean temperature +75 C. 75 kpa (over pressure) Transformer oil. Max daily mean oil temperature +9 C. Max temporary oil temperature +115 C. Not lower than 3 mm from the bushing flange. 1 kpa (over pressure) Horizontal to vertical Test tap: Dimensions according to IEEE, Type A. Max. service voltage 6 V. Voltage tap: Capacitance C 2 of test tap: Conductor: Markings: Dimensions according to IEEE, Type A. Max. service voltage 6 kv. < 5 pf Integrated tube conductor Conforming to IEC

TRANSFORMER BUSHINGS TYPE GSBK TECHNICAL GUIDE 7 Testing Routine testing The bushing is routine tested according to IEC 6137 and IEC 62271-211. The tests include measurement of partial discharge quantity, tan δ, capacitance and power frequency voltage withstand test. On each bushing, an external pressure test is performed and the tightness between the gas side and the oil side is confirmed. An individual routine test report is issued with each bushing. The routine test is carried out at room temperature with the bushing immersed in transformer oil. 2 Test tap. Type tests Type tests have been performed according to above standards and are available on request. Special tests A number of tests not specified by the above standards have also been performed and summaries are available on request. Test tap The outer conducting layer of the condenser core is connected to an insulated test tap on the flange. During operation the protective cap must be fitted in order to ground the outer layer to the flange. The maximum test voltage is 2 kv, 5 Hz for 1 minute. The maximum service voltage is 6 V. Voltage tap is available as on request. The maximum test voltage is 2 kv, 5 Hz for 1 minute. The maximum service voltage is 6 kv. The test tap and voltage tap have dimensions according to IEEE, potential tap type A.

8 TRANSFORMER BUSHINGS TYPE GSBK TECHNICAL GUIDE Electrical data Table 2. Electrical data. Ratings GSBK 17 245 362 42 55 Rated voltage IEC (kv), U m 17 245 362 42 55 Rated phase-to-ground voltage IEC (kv) 98 141 29 242 317 Basic Insulation Level (kv) (Equal to dry lightning impulse withstand voltage.) 75 15 13 155 1675 Dry switching impulse level (kv), SI N.A. 85 15 1175 13 Dry power frequency. Routine test 1 minute (kv) 365 56 63 695 75 Rated current (A), I r Note! Higher current ratings are available on request. Al conductor 16 16 16 16 125 Cu conductor 25 25 25 25 25 Rated frequency (Hz), fr 5/6 5/6 5/6 5/6 5/6 Temporary over voltage (kv) IEC (phase-toground voltage) 17 196 29 336 44 Space for current transformer (mm) 3/6 3/6 3/6 3/6 3/6 Nominal capacitance between conductor and test tap C 1 ±1 % (pf) 496/656 5/622 45/494 346/424 286/352 6 Nameplate with marking example.

TRANSFORMER BUSHINGS TYPE GSBK TECHNICAL GUIDE 9 Dimensions D4 R1 Ø 87 Shield SF 6 side R1 Ø 87 R58 17 72 R58 R58 R1 R1 L1 L5 D1 GSBK 17 GSBK 245-55 Flange SF 6 side 1.6 D7 x n1 L L3 L4 D5 D6 L2 D2 Flange oil side D1 x n2 D8 D9 D3 3 Dimensions.

1 TRANSFORMER BUSHINGS TYPE GSBK TECHNICAL GUIDE Table 3. Dimensions. Dimensions are subject to modification without notice. Type GSBK Rated current (A) Cat. No. 1ZSC... Dimensions in mm Test tap Voltage tap 6 kv L L1 L2 L3 L4 L5 D1 D2 17 16 917-AAA 917-ABA 147 52 75 2 3 378 188 18 -AAB -ABB 177 52 15 2 6 378 188 18 17 25 917-ACA 917-ADA 147 52 75 2 3 378 188 18 -ACB -ADB 177 52 15 2 6 378 188 18 245 16 9245-AAA 9245-ABA 189 77 92 2 3 663 214 26 -AAB -ABB 219 77 122 2 6 663 214 26 245 25 9245-ACA 9245-ADA 189 77 92 2 3 663 214 26 -ACB -ADB 219 77 122 2 6 663 214 26 362 16 9362-AAA 9362-ABA 2285 15 135 2 3 943 266 256 -AAB -ABB 2585 15 1335 2 6 943 266 256 362 25 9362-ACA 9362-ADA 2285 15 135 2 3 943 266 256 -ACB ADB 2585 15 1335 2 6 943 266 256 42 16 942-AAA 942-ABA 234 15 19 2 3 943 31 29 -AAB -ABB 264 15 139 2 6 943 31 29 42 25 942-ACA 942-ADA 234 15 19 2 3 943 31 29 -ACB -ADB 264 15 139 2 6 943 31 29 55 125 955-AAA 955-ABA 2535 15 1285 2 3 943 355 342 -AAB -ABB 2835 15 1585 2 6 943 355 342 55 25 955-ACA 955-ADA 2535 15 1285 2 3 943 355 342 -ACB -ADB 2835 15 1585 2 6 943 355 342

TRANSFORMER BUSHINGS TYPE GSBK TECHNICAL GUIDE 11 D3 D4 D5 D6 D7 x n1 D8 D9 D1 x n2 Space for current transformer (mm) Net mass (kg) Cantilever load Max operating load (kn) 146 187 335 35 16 x 8 335 29 15 x 12 3 68 2 4 146 187 335 35 16 x 8 335 29 15 x 12 6 78 2 4 146 187 335 35 16 x 8 335 29 15 x 12 3 96 2 4 146 187 335 35 16 x 8 335 29 15 x 12 6 113 2 4 146 187 565 535 16 x 16 45 4 23 x 12 3 114 2 4 146 187 565 535 16 x 16 45 4 23 x 12 6 128 2 4 146 187 565 535 16 x 16 45 4 23 x 12 3 152 2 4 146 187 565 535 16 x 16 45 4 23 x 12 6 171 2 4 146 187 69 64 2 x 16 5 4 23 x 12 3 178 2 4 146 187 69 64 2 x 16 5 4 23 x 12 6 198 2 4 146 187 69 64 2 x 16 5 4 23 x 12 3 227 2 4 146 187 69 64 2 x 16 5 4 23 x 12 6 253 2 4 146 187 69 64 2 x 16 5 45 23 x 12 3 24 2 4 146 187 69 64 2 x 16 5 45 23 x 12 6 231 2 4 146 187 69 64 2 x 16 5 45 23 x 12 3 25 2 4 146 187 69 64 2 x 16 5 45 23 x 12 6 28 2 4 146 187 69 64 2 x 16 55 5 23 x 12 3 258 2 4 146 187 69 64 2 x 16 55 5 23 x 12 6 294 2 4 146 187 69 64 2 x 16 55 5 23 x 12 3 312 2 4 146 187 69 64 2 x 16 55 5 23 x 12 6 354 2 4 Test load (kn)

12 TRANSFORMER BUSHINGS TYPE GSBK TECHNICAL GUIDE Connection details Draw rod system The draw rod system offers the following advantages compared to other connection systems: No hand holes required in the transformer tank. Easy bushing installation and removal no connection work inside the transformer at site. No special supports required in the transformer as is the case with plug contacts. Perfect guiding of the bushing into the transformer. The lower end shield may be fixed to the contact and will thus be correctly positioned with respect to the lower end plate of the bushing. The center tube of the bushing is used as current conductor. The transformer leads are fitted with cable lugs, which are bolted to a bottom contact. This contact is pressed against the bottom end of the bushing tube by a steel draw rod. The upper end of this rod is bolted to a compensating device, which consists of a spring and is so designed that it gives the required contact pressure at all temperatures. The draw rod is divided at the level of the flange. If required by the transport conditions, an additional joint can be positioned below the flange. This must be stated in the order. The lower part with contact end shield can then be secured to the cover during transport and storage of the transformer. Bottom contacts with 4 threaded holes for cable lugs are available. The bottom contacts are made of copper in one piece. To this bottom contact there is a suitable end shield, cat. No. 1ZSC9993. Special bottom contacts are available on request. Catalogue number for draw rod: 1ZSC9994. The draw rod consists of bottom contact, rods, compensating device, joints, washers and nut. Threaded hole M8 for pulling wire L 25 Additional joint on request 6 L2 64 45 H1 min 2 M12 (4x) 4 Draw rod system.

TRANSFORMER BUSHINGS TYPE GSBK TECHNICAL GUIDE 13 Fixed bottom contact The fixed bottom contact (Cat. No. 1ZSC9992-AAE) uses the same bottom contact as in the draw rod system, i.e. it is made of copper in one piece and has 4 threaded holes for cable lugs. The fixed bottom contact system also uses the center tube as a current conductor but it is secured to the center tube with a pulling ring instead of the draw rod. The pulling ring is made of aluminum and is threaded on to the center tube. The bottom contact is then fastened to the ring with six M1 bolts. Standard end-shields with Cat. No. 1ZSC9993, is suitable for the bottom contact. SF 6 side terminal The dimensions on the SF 6 side terminal fully comply to IEC 62271-211 and include 4 threaded holes for GIS connection. The terminal is fitted to the top end of the conductor tube by means of bolts, screwed into a pulling ring. The terminal surface for GIS connection is silver plated. Special terminals are available on request. 5 Fixed bottom contact. 64 45 M12 (4x) Standard end-shield The end-shield is made of aluminum and coated with insulating epoxy paint or 3 mm of pressboard. The design enables easy installation and should be used with standard draw rod bottom contact, or with the fixed bottom contact system. Table 4. Standard end-shield. Cat. No. 1ZSC9993-AEA 1ZSC9993-AEB Coating Epoxy paint 3 mm pressboard 6 SF 6 side terminal.

14 TRANSFORMER BUSHINGS TYPE GSBK TECHNICAL GUIDE Conductor loading The GSBK bushings fulfill the temperature rise test requirements according to IEC for the currents in the table below. The rated thermal short-time current (I th ) is calculated according to IEC 6137. Contact the supplier for current ratings for GSBK in oil - oil applications. Table 5. Conductor loading. Bushing GSBK Rated current A Short-time current (I th ) ka, rms 1 s 2 s 17 16 57 4 1 25 88 63 156 245 16 57 4 1 25 88 63 156 362 16 57 4 1 25 88 63 156 42 16 57 4 1 25 88 63 156 55 125 57 4 1 25 88 63 156 Dynamic current (I d ) ka, peak Overloading of bushings according to IEC If the conductor for the bushing is selected with 12 % of the rated current of the transformer, the bushing is considered to be able to withstand the overload conditions stated in IEC 676-7 when following the directions: for long time and short time emergency loading the oil temperature must be 115 C max. and the daily mean oil temperature must be 9 C max. For overload conditions other than the above-mentioned IEC overload, contact the supplier for permissible currents and temperatures. Short-time current The rated thermal short-time current (I th ) is calculated according to IEC 6137.

TRANSFORMER BUSHINGS TYPE GSBK TECHNICAL GUIDE 15 Recommendations for positioning The maximum stresses in the oil at the surface of the shield and the parts surrounding the bushing must be limited to the normal values for insulated conductors and other similar components in the same transformer. The withstand voltages in a specific case depend upon many factors beyond the control of the bushing manufacturer. Therefore the configurations and distances given in the table and figures are only intended as guidelines. D3 D4 1 /3 x L4 max L4 Table 6. Recommendations for positioning. Type GSBK E (mm) BIL L4 (mm) d3 (mm) d4 (mm) E 17 3 75 52±1 3 22 6 75 52±1 3 22 +3 +3 min R5 245 3 15 77±2 45 45 6 15 77±2 45 45 +5 +5 3 362 3 1175 15±2 54 54 +5 6 1175 15±2 54 54 42 3 155 15±2 54 54 6 155 15±2 54 54 +5 +5 +5 7 Recommendations for positioning. R 55 3 155 15±2 54 54 +5 3 1675 15±2 58 54 +5 6 155 15±2 54 54 +5 6 1675 15±2 58 54 +5 55 R25 5 R296 8 45 Radius (mm) 4 35 R35 265 3 25 2 3 35 4 45 5 55 6 65 7 75 U (kv) R9 Ø 142 Ø 258 R32 8 Recommended minimum distance R, for standard shield at 1 minute power frequency (rms) test. 9 End shield.

16 TRANSFORMER BUSHINGS TYPE GSBK TECHNICAL GUIDE Ordering particulars When ordering, please state: Type and catalogue number for bushing Connection details: fixed bottom contact or draw rod Catalogue number for shield on oil side Additional accessories or modifications Test required, in addition to the normal routine tests

ABB AB, Components SE-771 8 Ludvika Sweden E-mail: sales@se.abb.com www.abb.com/transformercomponents Copyright 218 ABB. All rights reserved. Specifications subject to change without notice. 1ZSC563-AAA en, Rev. 7, 218-11-3