AC axial fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

Similar documents
AC axial fan. blades with special design (K series) with guard grille for full nozzle

AC axial fan. sickled blades (S series), single inlet Wall ring with guard grille

AC axial fan. sickled blades (S series) with guard grille for full nozzle

AC axial fan. sickled blades (S series) with full square nozzle

AC axial fan. straight blades (A series) with full round nozzle

AC axial fan. sickled blades (S series) Wall ring with guard grille

AC centrifugal fan. backward curved

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. backward curved

AC axial fan. sickled blades (S series) with guard grille for full nozzle

AC centrifugal fan - RadiCal

AC axial fan. sickled blades (S series)

AC axial fan. sickled blades (S series)

AC centrifugal module - RadiCal

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. forward-curved, dual-intake with housing (without flange)

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

AC centrifugal fan. forward-curved, single-intake with housing (flange)

AC centrifugal fan with housing (small flange)

Energy-saving motors (ESM)

Energy-saving axial fans. A solution specifically designed for unit cooler applications. The engineer s choice. 10-Position rotary switch

AC axial fans S series, Ø 500

Product Data Sheet 632 NU-006

Product Data Sheet 624 NR. The engineer's choice

Product Data Sheet DV5214 NU

Product Data Sheet 8314 HR-197

Product Data Sheet ACi 4420 HHR

Listen to the difference. The AxiTop diffuser.

Product Data Sheet 4118 N/ The engineer's choice

Product Data Sheet 8412 NHU-519

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

Product Data Sheet 3214 JH3-195

RadiPac EC centrifugal fans. New dimensions in efficiency: sizes 630 1,000

Product Data Sheet 3214 J/2H3F-191

Product Data Sheet ACi 4420 MLR

Product Data Sheet 4184 N/17X. The engineer's choice

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

Product Data Sheet 4184 NXHH

IBExU Institut für Sicherheitstechnik GmbH

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue


Product Data Sheet 614 N/2HH-169 The engineer's choice

product specification

4314/17T. Product Data Sheet INDEX

Voltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]

Product Data Sheet 8412 N/ The engineer's choice

Technical Specifications

AC axial fans, AC diagonal fans

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

Explosion and flame-proof cast iron electric motors

The new fan generation S-Force

Product Data Sheet 4184 NXHH

INSERTION flow sensor for continuous flow measurement

ELECTRIC MOTORS. Selection. Starting torque and nominal torque

CEB 71204/a of 13 december 2005 SLSHR. 3-Phase Totally Enclosed Induction Motor Steel Housing Water-Cooled 30 to 1800 kw

Motors- Basic principles. Expertise, performance, innovation

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

1LG0 Low-voltage Motors

AXIAL FAN WITH EXTERNAL ROTOR MOTOR

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

Digital display Pressure range ON/OFF output Linear output Model

Product Data Sheet 4414/2H

Data sheet. Etaline GN /1852 G10 Version no.: 1 Inline pump. Operating data. Design. Requested developed head m

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Kirby WRC Remote Condenser. With HyBlade EC Fans and AxiTop Diffuser

Lenze. Drives with worm gearboxes 52.

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS

Data sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES SIZES. MarelliMotori ASI.CT.033.2

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

LSN Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

LSES high efficiency three-phase asynchronous motors. General information

Product Data Sheet 4184 NGX

Performance. Perkins Engines Company Limited. Perkins Engines Company Limited. Peterborough PE1 5FQ United Kingdom Tel: +44 (0)

Flow volume: 2-24 l/min Max differential pressure: 10 bar Applications: Lubrication, circulation and transfer

Table of contents. Three-phase asynchronous motors DA

TD-SILENT Series (160 to 1000 models)

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

Lowara. Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733. SH Series. 60 Hz

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS

BRIZA 22 HYBRID HEATING & COOLING

: B3; B5; B14; B34; B35; V1

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

Climate Control Products

Pressure transmitters for industrial applications Type MBS 4510

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

1104D-44TG2 1104D-44TG kwm 1500/1800 rpm. ElectropaK. Series. Basic technical data. Performance

Brushless internal rotor motors ECI series. Drive solutions Industrial drive engineering

Explosion and flame-proof single phase electric motors

TAG2A TAG3A. Series kwm 1500/1800 rpm kwm 1500/1800 rpm ElectropaK. Ratings. Basic technical data

IN-LINE CENTRIFUGAL DUCT FANS VT Series

2-position electric actuators with Ball valves VBZ ½...11/4

Technical Documentation

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

MegaBox Product-specific information

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue

LSES high efficiency three-phase asynchronous motors General information

Transcription:

S4D45-AP3- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59344 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen County court Stuttgart HRB 594 Nominal data Type Motor S4D45-AP3- M4D74-GA Phase 3~ 3~ Nominal voltage VAC 46 46 Connection Y Y Frequency Hz 5 6 Type of data definition cs cs Speed min - 33 46 Power input W 85 38 Current draw A.54.6 Max. back pressure Pa 8 75 Min. ambient temperature C -5-5 Max. ambient temperature C 65 55 ml = Max. load me = Max. efficiency fa = Running at free air cs = Customer specs cu = Customer unit Subject to alterations Item no. 3846-5-998 ENG Revision 8466 Release 5-3- Page / 6

S4D45-AP3- Technical features Mass Size Surface of rotor Material of terminal box Material of blades Material of guard grille Number of blades 5 Direction of air flow Direction of rotation 7. kg 45 mm Coated in black ABS plastic Sheet steel, coated in black Steel, coated in black plastic (RAL95) "V" Counter-clockwise, seen on rotor Type of protection IP 44; Depending on installation and position as per EN 634-5 Insulation class "F" Humidity class F- Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Mounting position Condensate discharge holes Operation mode Motor bearing Touch current acc. IEC 699 (measuring network Fig. 4, TN system) Electrical leads Cable exit Protection class Product conforming to standard + 8 C - 4 C Shaft horizontal or rotor on bottom; rotor on top on request Rotor-side S Ball bearing <.75 ma Via terminal box Variable I (if protective earth is connected by customer) EN 6335-, motor does not have factory-installed overheating protection Item no. 3846-5-998 ENG Revision 8466 Release 5-3- Page / 6

S4D45-AP3- Product drawing Direction of air flow "V" Tightening torque.5 ±. Nm 3 Cable diameter: max. mm, tightening torque.3±. Nm Item no. 3846-5-998 ENG Revision 8466 Release 5-3- Page 3 / 6

S4D45-AP3- Connection screen Y Star connection L black L blue L3 brown PE green/yellow Item no. 3846-5-998 ENG Revision 8466 Release 5-3- Page 4 / 6

S4D45-AP3- Charts: Air flow 5 Hz pfs [Pa] 5 5 95 9 85 8 75 7 65 6 55 5 45 4 35 3 5 5 5 5 5 pfs @ rho=, kg/m³ qv [CFM]..5. 5 5 3 35 qv [m³/h] 4.5 45 3.,48,46,44,4,4,38,36,34,3,3,8,6,4,,,8,6,4,,,8,6,4, 5 pfs [InHO] Measurement: LU-38669 Air performance measured as per ISO 58 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 3347 / LpA measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. Measured values U V 46 46 f Hz 5 5 n min - 375 33 P e W 4 85 I A.49.54 qv m 3 /h 498 3475 p fs Pa 8 U = Supply voltage f = Frequency n = Speed P e = Power input I = Current draw qv = Air flow p fs = Pressure increase Item no. 3846-5-998 ENG Revision 8466 Release 5-3- Page 5 / 6

S4D45-AP3- Charts: Air flow 6 Hz pfs [Pa] 5 5 95 9 85 8 75 7 65 6 55 5 45 4 35 3 5 5 5 5. pfs @ rho=, kg/m³ qv [CFM].5. 3 qv [m³/h] 4.5 3. 5,48,46,44,4,4,38,36,34,3,3,8,6,4,,,8,6,4,,,8,6,4, pfs [InHO] Measurement: LU-3867 Air performance measured as per ISO 58 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 3347 / LpA measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. Measured values U V 46 46 f Hz 6 6 n min - 535 46 P e W 3 38 I A.53.6 qv m 3 /h 555 435 p fs Pa 75 U = Supply voltage f = Frequency n = Speed P e = Power input I = Current draw qv = Air flow p fs = Pressure increase Item no. 3846-5-998 ENG Revision 8466 Release 5-3- Page 6 / 6