PM45 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G

Similar documents
PM25 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G

PM25 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G

PM50 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G

PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G

PMV0 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G

MOTORS MV HYDRAULIC MOTORS T E C H N I C A L C A T A L O G

P90 VARIABLE DISPLACEMENT PUMP T E C H N I C A L C A T A L O G

P90 VARIABLE DISPLACEMENT PUMP T E C H N I C A L C A T A L O G

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

MOTORS M HYDRAULIC MOTORS

TPV Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 501 / 1009 / E

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

PW/PWE HEAVY-DUTY HYDROSTATIC PUMP T E C H N I C A L C A T A L O G

Axial Piston Variable Pump AA4VG

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

Series 20 Axial Piston Motors. Technical Information

Series 20 Axial Piston Motors. Technical Information

Axial Piston Fixed Motor A2FM

Series 20 Axial Piston Pumps. Technical Information

Axial Piston Variable Double Pump A8VO

Axial Piston Variable Motor A6VM

Axial Piston Variable Pump A4VG

Series 20 Axial Piston Pumps. Technical Information

THE PRODUCTION LINE OF PONAR WADOWICE

Axial piston variable motor A6VM series 71. Americas. RE-A Edition: Replaces:

TPV Variable Displacement Axial Piston Pumps CONTENTS. General Information. Installation Instructions. Technical Specifications 6-7

Axial Piston Variable Pump A4VG

Variable displacement axial piston pumps,

Axial piston variable motor A6VM series 65. Americas. RE-A Edition: Replaces:

2.4 HEAVY DUTY SERIES

AXIAL PISTON PUMPS VARIABLE DISPLACEMENT

TPV 1200 BTB. Variable Displacement Closed Loop System Axial Piston Compact Tandem Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 154 / 0413 / E

Axial piston variable pump (A)A4VSO

Series 90 Axial Piston Pumps. Technical Information

Series 40 Direct Displacement Pumps

Axial piston variable motor A6VM Series 63. Europe. RE-E Edition: Replaces:

Series 90 Axial Piston Motors. Technical Information

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 855 / 0817 / E

Axial piston variable motor A6VM series 71

Variable Displacement Pump A4VG for closed circuits

2.3 MEDIUM HEAVY DUTY SERIES

Axial Piston Variable Motor A6VM (US-Version)

Series 90 Axial Piston Pumps. Technical Information

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

H1 Axial Piston Tandem Pumps Size 045/053

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

Axial Piston Variable Motor A6VM

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Series 42 4T Axial Piston Tandem Pumps

Axial Piston Fixed Pump A17FNO Series 10

Axial piston variable pump A10V(S)O Series 31. Americas. RE-A Edition: Replaces:

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

Fixed Displacement Motor AA2FM (A2FM)

Axial Piston Variable Pump (A)A4VSG (US-Version)

Axial Piston Variable Motor AA6VM (A6VM)

CDM CREEPDRIVE MOTOR

Technical Information Axial Piston Motors Series 20 powersolutions.danfoss.com

Axial Piston Variable Motor A6VM

MSE03 HYDRAULIC MOTORS T E C H N I C A L C A T A L O G

MP1 Axial Piston Pumps Size 28/32, 38/45

MP1 Axial Piston Pumps Size 28/32, 38/45

Axial piston variable pump A4VG Series 40

TPV Variable Displacement Closed Loop System Axial Piston Pump MANUFACTURING THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 403 / 1110 / E

Variable Plug-in Motor A6VE

Axial piston variable pump A10VSO series 32

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS

VARIABLE PUMPS FOR CLOSED LOOP OPERATION type HV-02

TPV 4000 (EX 28-41) Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE TRANSMISSION LINE OF HANSA-TMP HT 16 / M / 280 / 1008 / E

Series 40 Axial Piston Motors

BENT AXIS PISTON MOTORS SERIES HPM FLANGE ISO HPM. pag.3

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

M7X / M7V Series. Swash Plate Type Axial Piston Motor. Precision Machinery Company

4T Axial Piston Pumps. Technical Information

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Series PVP Variable Volume Piston Pumps

Series 90 Axial Piston Pumps. Technical Information

Axial Piston Pump Series PV Design 45 Variable Displacement. Catalogue HY /UK February 2007

Variable Displacement Motor AA6VM (A6VM)

MK23 MKE23 COMPACT MOTORS T E C H N I C A L C A T A L O G

Eaton. Revised June, Heavy Duty Hydrostatic Transmissions. l r. Models 33 through 76 Hydrostatic Transmissions. We Manufacture.

Axial piston variable pump A10V(S)O Series 31

Axial piston variable pump A4VG Series 40. Americas. RE-A Edition: Replaces:

MKD04 COMPACT MOTORS

Heavy Duty Hydrostatic Transmissions

Axial piston variable pump A4VG Series 40

AXIAL PISTON MOTORS SHMF

Axial piston variable pump (A)A10VSO Series 31. Americas. RE-A Edition: Replaces:

Variable displacement axial piston pump type V30D

Axial piston variable pump A10VSO series 32. Americas. RE-A Issue: Replaces:

Axial piston fixed motor A2FM series 70. Americas. RE-A Edition:

Variable displacement axial piston pumps,

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design

VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

H1 Axial Piston Pump Size 115/130, Single. Technical Information

MK09 COMPACT MOTORS T E C H N I C A L C A T A L O G

Axial Piston Variable Pump A10VO

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

UŽSISAKYKITE internetu telefonu el. paštu

Axial piston units A10FZO, A10VZO and A10FZG, A10VZG Series 10 for variable-speed drives

Transcription:

PM45 VRILE DISPLCEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C L C T L O G

PM45 - Variable displacement pump POCLIN HYDRULICS OVERVIEW PM45 is a variable displacement, axial piston pump, with swashplate system, for closed loop hydrostatic transmissions. It provides a continuously variable flow rate between zero and maximum in forward and reverse direction. Flow rate is proportional to rotation speed and swashplate angle. It can feature a charge pump to keep the circuit pressurised. This avoids risk of cavitations and ensures a good performance of the transmission. It offers several types of servo control: servo mechanical, servo hydraulic, hydraulic automotive, electrical and electro-proportional. It is equipped with high pressure relief valves and can be delivered with auxiliary gear pumps. It is available in single or tandem versions. s options, PM45 can be featured with flushing valve, filter on charge pressure line and safety devices to ensure safe operation of the machine. Displacement Theoretical Flow at rated speed cm³/rev [in³/rev.] L/min [GPM] PM45-35 PM45-40 PM45-45 PM45-52 35 [2.14] 126 [33.28] 40 [2.44] 144 [38.04] Rated speed rpm 3 600 Rated pressure bar [PSI] 250 [3 625] Max. Pressure bar [PSI] 350 [5 076] Mounting flange Controls SE 45 [2.75] 162 [42.79] 52 [3.17] 187,2 [49.45] Servo mechanical, servo hydraulic, hydraulic automotive, electrical, electro-proportional Mass kg [lb] 28 [61.7] with servo control Rotation Clockwise or Counterclockwise 2 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 CONTENT MODEL CODE 4 TECHNICL SPECIFICTIONS 6 Features 6 Performances 6 Main dimensions 7 Port characteristics 7 OPERTING PRMETERS 9 Operating parameters 9 Charge pressure 9 Case pressure 9 Pressure ratings 9 Speed ratings 9 Inlet pressure 10 Theoretical output 10 Poclain Hydraulics recommandations for fluid 10 Fluid and filtration 11 Viscosity range 11 Model Code Technical specifications Operating SYSTEM DESIGN PRMETERS 12 Sizing equations 12 Redundant braking system requirement 12 Loop flushing 12 Reservoir 13 Case drain usage for tandem pump 13 Differential pressure 13 earing life and external shaft loading 14 Hydraulic unit life 15 Mounting flange loads 15 FETURES 16 High pressure relief valve 16 Charge relief valve 17 Charge pump 18 Displacement limiters 19 y-pass 19 Mounting flange and shafts 20 uxiliary mounting pad 22 Tandem pumps 24 Gear pumps 25 CONTROLS 26 Mechanical servo control with feed back 26 Hydraulic servo control 28 Electrical on-off servo control 30 Electrico-proportional servo control 32 Hydraulic automotive control 34 Electrico-proportional servo control with feed back 36 Hydraulic servo control with feed back 38 OPTIONS 41 SE flange ports 41 Mechanical inching 41 Filter on pressure line 42 Pressure cut-off valve 43 Neutral position switch 44 Flushing valve 45 System design Features Options Controls 10/02/2011 3

MODEL CODE PM45 - Variable displacement pump POCLIN HYDRULICS MODEL 4 5 1 2 3 4 5 6 1 Displacement cm 3 /rev [in 3 /rev] 35 [2.14] 35 40 [2.44] 40 45 [2.75] 45 52 [3.17] 52 2 Mounting flange and shaft SE ; splined shaft z =13, 16/32 D.P. S3 SE ; splined shaft z =15, 16/32 D.P. S4 SE ; key shaft Ø 25,38 mm [dia. 1.00 in] C3 3 Control Mechanical servo control with feed back Hydraulic servo control Hydraulic servo control with feed back Hydraulic automotive control 12V Hydraulic automotive control 24V Electrical on-off servo control with return spring without electrovalve Electrical on-off servo control with return spring and electrovalve 12V Electrical on-off servo control with return spring and electrovalve 24V Electrical on-off servo control without electrovalve Electrical on-off servo control with electrovalve 12V Electrical on-off servo control with electrovalve 24V Electro-proportional servo control 12V Electro-proportional servo control 24V Electro-proportional servo control with feed back 12V Electro-proportional servo control with feed back 24V S T D12 D24 00 12 24 C00 C12 C24 P12 P24 Q12 Q24 5 High pressure relief valve setting Operating pressure bar [PSI] Without valve (only check valve) 00 150 [2 175] 15 200 [2 900] 20 250 [3 625] 25 300 [4 351] 30 350 [5 076] 35 4 Restrictor mm [in] Without restrictor 00 Ø 0,6 [dia. 0.023] 06 Ø 0,7 [dia. 0.027] 07 Ø 0,8 [dia. 0.031] 08 Ø 0,9 [dia. 0.035] 09 Ø 1,0 [dia. 0.039] 10 Ø 1,2 [dia. 0.047] 12 6 Rotation Clockwise Counter clockwise R L 4 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 CODE 7 8 9 10 11 Technical specifications Model Code 7 Charge relief valve setting bar [PSI] Without charge relief valve 00 26 [377] 26 8 Charge pump displacement cm 3 /rev [in 3 /rev] Without charge pump 00 11 [0.67] 11 16,9 [1.03] 17 11 Options Without option 00 Roller bearing CR Filter on pressure line without clogging indicator F0 Filter on pressure line with clogging indicator F2 SE flange ports FS Mechanical inching for control D IC Pressure cut-off valve LP Neutral position switch for control MI Flushing valve VS Operating System design 9 uxiliary mounting pad Without auxiliary mounting pad SE flange; z = 9 SE flange; z = 11 SE flange; z = 13 S E It is possible to combine several options. Consult your Poclain Hydraulics application engineer for more information. Features SE flange; z = 15 C Tandem (without charge pump) T 10 Gear pump cm 3 /rev [cu.in/rev] Without gear pump 00 SE flange (if digit 9 = ) 4,0 [0.24] 04 6,0 [0.37] 06 8,5 [0.52] 08 11,0 [0.67] 11 14 [0.85] 14 16,5 [1.00] 17 19,5 [1.19] 20 22,5 [1.37] 22 26 [1.59] 26 Options Controls 10/02/2011 5

PM45 - Variable displacement pump POCLIN HYDRULICS TECHNICL SPECIFICTIONS Features PM45-35 PM45-40 PM45-45 PM45-52 Displacement cm³/rev [in³/rev.] 35 [2.14] 40 [2.44] 45 [2.75] 52 [3.17] Theoretical flow at rated speed (3600 rpm) Max. Theoretical absorbed power at 320 bar [4 641 PSI] Theorical absorbed torque at 100 bar [1 450 PSI] L/min [GPM] 126 [33.28] 144 [38.04] 162 [42.79] 187,2 [49.45] KW 67,2 76,8 86,4 99,8 N.m [in.lbf] 55,7 [493] 63,7 [564] 71,7 [635] 82,8 [733] Moment of inertia kg.m² [slug.ft²] 0.0054 [0.0038] Internal charge pump cm 3 /rev [in 3 /rev] 11 [0.67] or 16,9 [1.03] Charge relief valve setting bar [PSI] From 15 [217.5] to 30 [435] High pressure relief setting bar [PSI] Max. 350 [5 076] Type of mounting SE, SE or key shaft Mass kg [lb] 28 [61.7] with servo control Performances Overall efficiency curves Oil ISO VG46, temperature = 50 C [122 F]. Pump displacement = 45 cm³/rev [2.75 in³/rev.] 100 95 225 bar [3 263 PSI] Overall efficiency (%) 90 85 80 150 bar [2 175 PSI] 300 bar [4 351 PSI] 75 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250 Pump speed (rpm) 6 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Main dimensions PM45 - SE - splined shaft with hydraulic servo control and without auxiliary mounting pad 1 2 3 4 5 6 7 8 9 10 11 4 5 S4 S S Model Code 103 [4.05] 112,5 [4.43] Ø 101,6 h7 [dia. 4.00] 28 [1.10] 37,5 [1.48] 37,5 [1.48] X 125 [4.92] 90 [3.54] Technical specifications 120 [4.72] 174 [6.85] 237,5 [9.35] 146 [5.75] 174 [6.85] Operating View X 55 [2.17] 55 [2.17] 24,5[0.96] 24,5 [0.96] 31 [1.22] 86,5 [3.40] 172 [6.77] 34 [1.34] 87 [3.42] 81,5 [3.21] 33 [1.30] 33 [1.30] 11,5 [0.45] 11,5 [0.45] 11 [0.43] 11 [0.43] 174 [6.85] 120 [4.72] 28 [1.10] 85,7 [3.37] System design Features Port characteristics M1 R G1 G2 C M2 T2 M4 M5 T1 M3 M6 Port Function ISO 1179-1 (standard) / Services 1 GS C Case pressure 1/4 GS G1/G2 uxiliary 1/4 GS M1/M2 / pressure 1/4 GS M3/M4 Servo control 1/4 GS M5/M6 Pilot pressure 1/4 GS R Servo pilot pressure 1/4 GS S Suction 1 GS T1/T2 Drain 3/4 GS See option FS page 41 for SE port size. Options Controls 10/02/2011 7

PM45 - Variable displacement pump POCLIN HYDRULICS 8 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 OPERTING PRMETERS Operating parameters Speed ratings System pressure Inlet pressure Case pressure Charge pressure PM45-35 PM45-40 PM45-45 PM45-50 Minimum 700 Max. without load min -1 (rpm) 3 600 Max. with load 3 400 Rated Charge pressure 250 [3 625] Maximum bar [PSI] 350 [5 076] Minimum low loop 15 [218] Mini continuous bar (abs.) 0,8 [11.6] Mini (cold start) [in. Hg vac.] 0,5 [7.2] Continuous 1,5 [21.7] bar [PSI] Maximum (cold start) 2,5 [36.2] Standard version 26 [377] Max. charge pressure bar [PSI] 30 [435] charge flow is required to maintain a positive pressure in the low pressure loop of a closed loop hydrostatic transmission. Charge pressure ensures proper lubrication and rotating group operation. It is recommended to maintain the charge pressure at a minimum of 15 bar [218 PSI] above case pressure. For more details, refer to charge pump paragraph, page 18. Case pressure Case pressure must be maintained within the limits shown in the table ''Operating parameters''. Ensure housing is always filled with hydraulic fluid and especially during start-up of the machine. Model Code Technical specifications Operating System design Pressure ratings Maximum peak pressure It is the maximum allowable pressure. It is equivalent to the maximum setting of the maximum high pressure relief valve. self-propelled machine can reach the maximum peak pressure value no more than 1-2% of that work cycle. Work cycle fundamental factor for ensuring correct hydrostatic transmission sizing is the machine work cycle (pressure-time ratio, seasonality, pressure vs. percentage of time at max. displacement, machine type). Part service life depends on the correct choice in relation to the work cycle. Features Overloads It is mandatory to protect parts against any possible overloads. Speed ratings The table ''Operating parameters'' gives minimum and maximum rated speeds. Note that all displacements might operate under different speed limits. Definitions of these speed limits appear below. Maximum speed is the highest operating speed allowed. Over speeding reduces pump life time, can lead to loss of hydrostatic power and braking capacity. Never exceed the maximum speed limit under any operating conditions. Nominal speed is the speed offering the maximal efficiency. Options Controls 10/02/2011 9

PM45 - Variable displacement pump POCLIN HYDRULICS Inlet pressure Charge pump inlet pressure is key for acceptable pump life and performances. continuous inlet pressure of not less than 0,8 bar abs. [11.6 PSI abs.] is recommended. continuous inlet pressure less than 0.5 bar abs. [7.2 PSI abs.] indicates inadequate inlet design or a restricted filter. Pressures less than 0.5 bar abs. [7.2 PSI abs.] can happen at cold start, but should increase with oil temperature. Theoretical output Theoretical output flow is a function of pump displacement and speed. It is relevant to size the rest of the circuit. Theoretical flow does not take into account losses due to leakage or variations in displacement. Refer to performances, page 6, for volumetric and overall efficiencies at various operating speeds and pressures. Poclain Hydraulics recommandations for fluid Poclain hydraulics recommends the use of hydraulic fluids defined by the ISO 12380 and ISO 6743-4 standards. For temperate climates, the following types are recommended. HM 46 or HM 68 for fixed installations. HV 46 or HV 68 for mobile installations. HEES 46 for mobile installations. These specifications correspond to category 91H of the CETOP standard, parts 1, 2 and 3 of the DIN 51524 standard, and grades VG32, VG 46 and VG68 of the ISO 6743-4 standards. It is also possible to use TF, HD, HF, HFC or HFD type hydraulic fluid upon Poclain Hydraulics specific approval of the components operating conditions. Standardized designations for the fluids HM : Mineral fluids having specific antioxidant, anticorrosion and antiwear properties (HLP equivalent to DIN 51524 parts 1 and 2). HV : HM mineral fluids providing improved temperature and viscosity properties (DIN 51524 part 3). HEES :iodegradable fluids based on organic esters. It is also possible to use a fluid that meets the biodegradability criteria and is compatible in the event of accidental food contact. The IOHYDRN FG 46 fluid designed by the company Total has undergone testing of its properties and performance on our test benches. Since this type of fluid has not yet been categorized, it is the responsibility of machine manufacturers to validate its compatibility with all of the components used in order to guarantee that the intended functions will be fulfilled and this for the desired life time of all equipment items. For biodegradable fluids, consult your Poclain Hydraulics application engineer During operation, the temperature of the oil must be between 0 C [32 F] and 80 C [176 F]; the minimum and maximum temperatures may be exceeded momentarily by ± 20 C [± 68 F] for a duration of less than 30 minutes. For all applications outside these limits, please consult with your Poclain Hydraulics application engineer. 10 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Fluid and filtration The contaminating particles suspended in the hydraulic fluid cause the hydraulic mechanisms moving part wear. On hydraulic pumps, these parts operate with very small dimensional tolerances. In order to reach the part life, it is recommended to use a filter that maintains the hydraulic fluid contamination class at a max. of: Model Code 9 according to NS 1638 20/18/15 according to ISO 4406:1999 ccording to the type of application decided for the pump, it is necessary to use filtration elements with a filtration ratio of: 20 to 30 100 Making sure that this ratio does not worsen together with the increasing of the filter cartridge differential pressure. If these values cannot be observed, the component life will consequently be reduced and it is recommended to contact the Poclain Hydraulics Customer Service. Filters on charge circuit Filters on the charge circuit (F0-F2) are designed without by-pass. The max. pressure drop on the filtration part must not exceed 2 bar [29 PSI] (3 bar [43.5 PSI] in case of cold starting) at pump full rating. To monitor the pressure drop, It is recommended to use the clogging indicator on the filtration element (F2 option). Contact your Poclain Hydraulics pplication engineer, each time the pump is not charged by its internal charge pump. Filters on charge circuit are mounted on the pump special support. Filters assembling The suction filter is mounted on the suction line. Check that the pressure before the charge pump is 0.8 bar abs. [11.6 PSI abs.], measured on the pump suction port (0.5 bar [7.2 PSI] for cold starting). Technical specifications Operating Viscosity range For both max. efficiency and life of the unit, the operative viscosity should be chosen within the optimum range of: opt = optimum operating viscosity from 16 to 36 mm 2 /s [from 74.1 to 166.8 SUS] referred to the closed loop temperature. Working conditions: the following limits of viscosity apply min = 5 mm 2 /s [23 SUS] short-duration at a max. permissible leakage oil temperature of 90 C [194 F] max = 1000 mm 2 /s [4 634 SUS] short-duration, on cold start. For brief instants during the cold starting System design Optimum viscosity Hydraulic fluid temperature range For brief instants with leakage oil at 90 C Features Options Controls Ensure fluid temperature and viscosity limits are concurrently satisfied. 10/02/2011 11

PM45 - Variable displacement pump POCLIN HYDRULICS SYSTEM DESIGN PRMETERS Consult your Poclain Hydraulics application engineer to validate your design parameters before using the pump in your application. Sizing equations The following equations are helpful when sizing hydraulic pumps. Generally, the sizing process is initiated by an evaluation of the machine system to determine the required motor speed and torque to perform the necessary work function. First, the motor is sized to transmit the maximum required torque. The pump is then selected as a flow source to achieve the maximum motor speed. V g.n. v Output flow Q = (l/min) 1000 SI units US units Input torque M = V g. p 20.. m (N.m) Input power P = M. n. Q. p = 30 000 600. t (kw) Output flow Q = V g.n. v 231 [GPM] Input torque M = V g. p 2.. m [lbf.in] M.n. Q. Input power P = = p [hp] 198 000 1714. t V g =Displacement per revolution cm 3 /tr [in 3 /rev] p = p o - p i (system pressure) bar [PSI] n = Speed min -1 [rpm] v = Volumetric efficiency m = Mechanical efficiency t = Overall efficiency ( v. m) Redundant braking system requirement Unintended vehicle or machine movement hazard. The loss of hydrostatic drive line power, in any mode of operation (forward, neutral, or reverse) may cause the system to lose hydrostatic braking capacity. You must provide a braking system, redundant to the hydrostatic transmission, sufficient to stop and hold the vehicle or machine in the event of hydrostatic drive power loss. Loop flushing Closed circuit may require a flushing valve to meet temperature and cleanliness requirements. flushing valve takes a part of hot fluid flow from the low pressure loop of the system loop for cooling and filtering. Make sure that the charge pump provides adequate flow for the flushing valve flushing and the flushing valve does not cause charge pressure to drop below recommended limits. M1 G1 G2 R C M2 See option VS page 45 for more information. M6 M5 M3 M4 T1 T2 S 12 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Reservoir The reservoir provides clean fluid, dissipates heat, and removes entrained air from the hydraulic fluid. It allows for fluid volume changes associated with fluid expansion and cylinder differential volumes. Minimum reservoir capacity depends on the volume needed to perform these functions. Typically, a capacity of one half the charge pump flow (per minute) is satisfactory for a closed reservoir. Open circuit systems sharing a common reservoir require greater fluid capacity. Model Code Locate the reservoir outlet (suction line) near the bottom, allowing clearance for settling foreign particles. Use a 100-125 μm screen covering the outlet port. Place the reservoir inlet (return lines) below the lowest expected fluid level, as far away from the outlet as possible. Use a baffle (or baffles) between the reservoir inlet and outlet ports to promote de-aeration and reduce fluid surging. Case drain usage for tandem pump Technical specifications On tandem pumps, and to ensure lubrification of both pumps, excess flow from the first pump charge relief valve must be routed into the housing of the second pump. Tandem pumps with the option of opposing port endcaps do not follow the above rule. Operating G2-2 M6-1 M5-1 M1-1 G1-2 R-1 C-1 M2-1 1 M3-2 M4-2 M6-2 M5-2 M1-2 G1-1 R-2 C-2 M2-2 -2 M3-1 M4-1 System design T -1 S -2 Differential pressure The differential pressure is the High pressure relief valve setting minus Charge relief valve setting. Features M3 M4 M6 M5 M1 G1 G2 R C M2 T1 T2 S High pressure relief valve setting Differential pressure Charge relief valve setting = Max. system pressure Options Controls 10/02/2011 13

PM45 - Variable displacement pump POCLIN HYDRULICS earing life and external shaft loading earing life: earing life is a function of speed, pressure, swashplate angle and external loads. Oil type and viscosity impact bearing life.. earing life ( 10 hours) PM45-35 10 700 PM45-45 5 100 PM45-52 3 300 Shaft Loads Normal bearing life in 10 hours is shown in the above table. Figures have been calculated under the following operating conditions : continuous differential pressure of 130 bar [1 885 PSI], 1 800 rpm shaft speed, maximum displacement, without any external shaft side load. The data is based on a 50% forward, 50% reverse duty cycle, standard charge pump size, and standard charge pressure. PM65 pumps are designed with bearings that can accept external radial and thrust loads. The external radial shaft load limits depend on the load position, orientation, and operating conditions of the unit. The maximum permissible radial load (Re), is based on the maximum external moment (Me), and the distance (L) from the mounting flange to the load. It may be determined using the table and formula below. Thrust (axial) load limits are also shown. Re = Me / L ll external shaft loads affect bearing life. In applications with external shaft loads, minimize the impact by positioning the load at 90 or 270 as shown in the figure. Contact your Poclain Hydraulics representative for an evaluation of unit bearing life if: Continuously applied external loads exceed 25 % of the maximum allowable radial load Re. The pump swashplate is positioned on one side of center all or most of the time. The unit bearing life ( 10 ) is critical. External moment (Me) N.m [in.lbf] (ased on shaft deflection) Maximum shaft thrust N [lbf] (at P 180 bar [2 611 PSI] and 3 400 rpm) PM45-35 150 [1 328] 1 500 [337] PM45-45 107 [947] 1 500 [337] PM45-52 76 [673] 1 500 [337] Radial and thrust load position End view of shaft xis of swashplate rotation For an accurate calculation, consult your Poclain Hydraulics application engineer. 14 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Hydraulic unit life Hydraulic unit life is the life expectancy of the hydraulic components. It depends on speed and system pressure even if, system pressure is the dominant operating variable. High pressure, generated by high load, reduces hydraulic unit life. Design the hydraulic system according to the expected machine duty cycle. Take in consideration the expected percentages of time at various loads and speeds. sk your Poclain Hydraulics representative to calculate an appropriate pressure based your hydraulic system design. If duty cycle data is not available, input power and pump displacement are used to calculate system pressure. Model Code ll pressure limits are differential pressures (referenced to charge pressure), taking a normal charge pressure in consideration. PM65 pumps will meet satisfactory life expectancy if applied within the parameters specified in this technical documentation. For more detailed information on hydraulic unit life see Operating in page 9. Mounting flange loads dding tandem mounted pumps, and/or tandem auxillary pump(s), subjecting pumps to shock loads may generate excessive loads on the front mounting flange. The overhung load moment for multiple pump mounting can be estimated as shown in the figure bellow Technical specifications Overhung load example Mounting flange CG pump 1 uxiliary pad CG pump 2 Operating L1 L2 System design Estimating overhung load moments W = Weight of pump (kg) L = Distance from mounting flange to pump center of gravity (CG) M R = G R (W 1 L 1 + W 2 L 2 +... + W n L n ) M S = G S (W 1 L 1 + W 2 L 2 +... + W n L n ) Features Where: M R = Rated load moment (N.m) M S = Shock load moment (N.m) G R *= Rated (vibratory) acceleration (G s) (m/sec²) G S *= Maximum shock acceleration (G s) (m/sec²) *Calculations will be carried out by multiplying the gravity (g = 9.81 m/sec²) with a given factor. This factor depends on the application. llowable overhung load moment are shown in the above table. Exceeding these values requires additional pump support. Rated moment (MR) N.m [in.lbf] Shock load moment (MS) N.m [in.lbf] PM45-35 900 [7 966] 2 000 [17 701] PM45-45 900 [7 966] 2 000 [17 701] PM45-52 900 [7 966] 2 000 [17 701] For an accurate calculation, consult your Poclain Hydraulics application engineer. Options Controls 10/02/2011 15

PM45 - Variable displacement pump POCLIN HYDRULICS FETURES High pressure relief valve The High pressure relief valves maintain circuit pressure in the proper range. The check valves allow charge flow to replenish the low pressure loop of the circuit. The high pressure relief valves ensure a high pressure protection of the high pressure loop of the circuit. High pressure relief valves are available in a range of settings. When high pressure relief valves are not desired, pumps may be equipped with charge circuit check valves only. High pressure relief valves are intended for transient overpressure protection and are not intended for continuous pressure control. Flow over relief valves for extended periods of time may result in severe heat build up. High flows over relief valves may result in pressure levels exceeding the nominal valve setting and potential damage to system components. 1 2 3 4 5 6 7 8 9 10 11 4 5 Hight pressure relief valve vailable setting bar [PSI] Without - 00 M3 M4 M6 M5 M1 G1 G2 R C M2 150 [2 175] 15 200 [2 900] 20 With 250 [3 625] 25 300 [4 351] 30 T1 T2 S 350 [5 076] 35 ISO VG46 hydraulic fluid at 50 C [122 F] High pressure relief valve Pressure Flow 16 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Charge relief valve The charge pressure relief valve provides a relief outlet for charge circuit. This valve is used to set the charge pressure of the circuit. Flow through the valve is ported to case. The nominal charge relief setting is referenced to case pressure. Model Code 4 5 Incorrect charge pressure settings may result in the inability to build required system pressure and/or inadequate loop flushing flows. Ensure correct charge pressure under all conditions of operation to maintain pump control performance. 1 2 3 4 5 6 7 8 9 10 11 Technical specifications Charge relief valve vailable setting bar [PSI] M6 M5 M1 G1 G2 R C M2 Operating Without - 00 M3 M4 With 26 [377] 26 T1 T2 S System design Features ISO VG46 hydraulic fluid at 50 C [122 F] Pressure difference Charge relief valve Options Controls Pump speed (rpm) 10/02/2011 17

PM45 - Variable displacement pump POCLIN HYDRULICS Charge pump Charge flow is required on all PM45 pumps used in closed circuit installations. The charge pump provides flow to make up internal leakage, maintain a positive pressure in the main circuit, provide flow for cooling and filtration, replace any leakage losses from external valving or auxiliary systems, and to provide flow and pressure for the control system. Many factors influence the charge flow requirements. These factors include system pressure, pump speed, pump swashplate angle, type of fluid, temperature, size of heat exchanger, length and size of hydraulic lines, control response characteristics, auxiliary flow requirements, hydrostatic motor type, etc. Unusual application conditions may require a more detailed review of charge pump sizing. Charge pressure must be maintained at a specified level under all operating conditions to prevent damage to the transmission. Poclain Hydraulics recommends testing under actual operating conditions to verify this. M6 M5 M1 G1 G2 R C M2 M3 M4 T1 T2 S Charge pump sizing/selection In most applications a general guideline is that the charge pump displacement should be at least 20% of the main pump displacement. 4 5 1 2 3 4 5 6 7 8 9 10 11 Charge pump Displacement cm³/rev [in³/rev] Rated speed (rpm) Without - - 00 With 11 [0.67] 3600 11 16,9 [1.03] 3600 17 Contact your Poclain Hydraulics application engineer for more information. 18 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Displacement limiters PM45 are designed with mechanical displacement (stroke) limiters. You can limit maximum displacement of the pump to a certain per-cent of its maximum displacement to near zero in both direction. The displacement limiters are located on the both sides of the servo piston and are adjustable by screw. Model Code Take care in adjusting displacement limiters to avoid an undesirable condition of output flow or speed. Retorque the sealing lock nut after every adjustment to prevent an unexpected change in output conditions and to prevent external leakage during pump operation. Max. displacement adjustement Technical specifications Operating Neutral position adjustement Max. displacement adjustement System design y-pass PM45 features a by-pass function. y-passing Port and Port is achieved by unscrewing a screw located on the cover. The by-pass connect the ports - and must be use only in emergency case and only for short movement. M6 M5 M1 G1 G2 R C M2 Features M3 M4 T1 T2 S To avoid leakage, do NOT exceed two turns of the screw. y-pass valve is intended for moving a machine for very short distances at very slow speeds. It is NOT intended as tow valve. Options Controls 10/02/2011 19

PM45 - Variable displacement pump POCLIN HYDRULICS Mounting flange and shafts SE - Splined shaft 4 5 1 2 3 4 5 6 7 8 9 10 11 S3 13 teeth Max. torque: 220 Nm [1947 in.lbf] 8 [0.31] 38 [1.50] 26 [1.02] 20 [0.79] M8 +0,000-0,035 Ø 101,6 h7 [dia. 4.00 h7 ] +0,000-0,001 Splined NSI 92.1 Pitch 16/32 DP Pressure angle 30 Tolerance class: 5 9,5 [0.37] 46 [1.81] S4 15 teeth Max. torque: 360 Nm [3186 in.lbf] 8 [0.31] 38 [1.50] 26 [1.02] 20 [0.79] M8 +0,000-0,035 Ø 101,6 h7 +0,000 [dia. 4.00 h7-0,001 ] Splined NSI 92.1 Pitch 16/32 DP Pressure angle 30 Tolerance class: 5 9,5 [0.37] 46 [1.81] 20 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 SE - Key shaft 4 5 C3 1 2 3 4 5 6 7 8 9 10 11 Model Code Ø 25,38 mm [dia. 1.00 in] Max. torque: 220 Nm [1947 in.lbf] 8 [0.31] 70 [2.75] 19 [0.75] M8 28,23 ±0.1 [1.11 ± 0.004] +0,000-0,035 Technical specifications Operating System design Options Controls Features Ø 101,6 h7 +0,000 [dia. 4.00 h7-0,001 ] 43.9 [1.73] +0,000 6,35 h9-0,036 +0,000 [0.25 h9-0,001 ] 4,5 [0.18] 9,5 [0.37] 78 [3.07] +0,000-0,013 Ø 25,38 h6 +0,000 [dia. 1.00 h6-0,0005 ] 10/02/2011 21

PM45 - Variable displacement pump POCLIN HYDRULICS uxiliary mounting pad SE flanges 4 5 1 2 3 4 5 6 7 8 9 10 11 Flange type SE Number of teeth 9 11 Pitch 5/8 pitch 16/32 DP 3/4 pitch 16/32 DP Max. torque N.m [in.lbf] 80 [708] 160 [1 416] E 00 Without charge pump 11 With charge pump: 11,0 cm 3 /rev [0.67 in 3 /rev] 17 With charge pump: 16,9 cm 3 /rev [1.03 in 3 /rev] Splined NSI 92.1a Pressure angle 30 Tolerance class: 5 20 [0.79] Ø 106,375 [dia. 4.19] 135 [5.31] 4 x M10 239 [9.41] 10 [0.40] +0.071 +0.036 Ø 82,55 F7 [dia. 3.25 F7 +0.001 ] +0.003 Do not rotate the thru shaft cover. 22 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 SE- and SE- flanges 4 5 1 2 3 4 5 6 7 8 9 10 11 Model Code Flange type Number of teeth SE 13 SE 15 Pitch 7/8 pitch 16/32 DP 1 pitch 16/32 DP Max. torque N.m [in.lbf] 230 [2 036] 360 [3 186] C Technical specifications 00 Without charge pump 11 With charge pump: 11,0 cm 3 /rev [0.67 in 3 /rev] Operating 17 With charge pump: 16,9 cm 3 /rev [1.03 in 3 /rev] Splined NSI 92.1a Pressure angle 30 Tolerance class: 5 Ø 146 [dia. 5.75] 177 [6.97] Ø 101,6 F7 +0.003 +0.001 +0.071 +0.036 [dia. 4.00 F7 ] System design Features 4 x M12 Do not rotate the thru shaft cover. 239 [9.41] 21 [0.83] Options Controls 10 [0.40] 10/02/2011 23

PM45 - Variable displacement pump POCLIN HYDRULICS Tandem pumps Max. torque intermediate coupling 360 N.m [3 186 in.lbf] Front axial pump Rear axial pump Next pump M e imput torque M e1 for the first pump M e2 for the second pump M e3 for the next pump Torque required by auxiliary pumps is additive. Ensure requirements don t exceed shaft torque ratings. Front axial pump Rear axial pump + 4 5 4 5 S4 1 2 3 4 5 6 7 8 9 10 11 Number of charge pump in the tandem xial pump Mounting flange and shaft Charge pump uxiliary mounting flange 0 charge pump 1 charge pump Front SE ; 13 teeth SE ; 15 teeth S3 S4 Rear SE ; 15 teeth S4 Without 00 Front SE ; 13 teeth SE ; 15 teeth S3 S4 Rear SE ; 15 teeth S4 With Without 00 Tandem fitting T Without fitting SE ; 9 teeth SE ; 11 teeth SE ; 13 teeth SE ; 15 teeth Without 00 Tandem fitting T 11 or 17 Without fitting SE ; 9 teeth SE ; 11 teeth SE ; 13 teeth SE ; 15 teeth S E C S E C 2 charge pumps SE ; 13 teeth S3 Front SE ; 15 teeth S4 With Rear SE ; 15 teeth S4 With 11 or 17 11 or 17 SE ; 15 teeth Without fitting SE ; 9 teeth SE ; 11 teeth SE ; 13 teeth SE ; 15 teeth C S E C 24 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 M6-1 M5-1 M1-1 G1-2 R-1 C-1 M2-1 1 M3-2 M4-2 M6-2 M5-2 M1-2 G1-1 R-2 C-2 M2-2 G2-2 -2 Model Code M3-1 M4-1 T -1 Ports T and G of the first pump must be connectedwith ports T and G of the second pump. S -2 Technical specifications Gear pumps 4 5 1 2 3 4 5 6 7 8 9 10 11 Operating uxiliary mounting pad Displacement Pressure Dimension Mass Efficiency Continuous max. pressure Gear pump Max. intermittent pressure Max. peak pressure C System design cm 3 /rev [cu.in/rev] bar [PSI] bar [PSI] bar [PSI] mm [in] mm [in] mm [in] Kg [lb] % SE flange 04 06 08 4,0 [0.24] 6,0 [0.37] 8,5 [0.52] 250 [3 625] 250 [3 625] 250 [3 625] 270 [3 915] 270 [3 915] 270 [3 915] 290 [4 205] 290 [4 205] 290 [4 205] 93 [3.66] 96,3 [3.79] 100,5 [3.96] 2,30 [5.07] 2,45 [5.40] 2,60 [5.73] Features 11 11,0 [0.67] 250 [3 625] 270 [3 915] 290 [4 205] 104,6 [4.12] 2,70 [5.95] C 14 17 20 23 26 14 [0.85] 16,5 [1.00] 19,5 [1.19] 22,5 [1.37] 26 [1.59] 250 [3 625] 230 [3 335] 210 [3 045] 190 [2 755] 170 [2 465] 270 [3 915] 240 [3 480] 220 [3 190] 200 [2 900] 180 [2 610] 290 [4 205] 250 [3 625] 230 [3 335] 210 [3 045] 190 [2 755] 109,6 [4.31] 113,8 [4.48] 118,8 [4.68] 123,8 [4.87] 129,6 [5.10] 130,4 [5.13] Gear pumps are always delivered flanged on the axial pump. They can not be sold alone. 95 [3.74] 2,80 [6.17] 2,95 [6.51] 3,10 [6.84] 3,25 [7.17] 3,40 [7.50] 95* * Value collected during the testing at 1500 rpm Options Controls 10/02/2011 25

PM45 - Variable displacement pump POCLIN HYDRULICS Mechanical servo control with feed back CONTROLS 4 5 1 2 3 4 5 6 7 8 9 10 11 The variation in pump displacement is obtained by rotating the drive lever situated on the servo control. n internal channel, linked to the charge pump, feeds a hydraulic servo valve which supplies oil into the cylinder which is in turn linked to the pump swashplate. The maximum rotation of the Iever, with respect to 0 is 40 for both rotation directions; thus permitting the optimum control of the displacement. t every lever angle there is a corresponding pump displacement. On the (T) return arm of the rotating distributor a restrictor (Rs) is mounted which regulates the servo control shifting speed, thus avoiding sudden accelerations and stoppages. The effort of moving the lever is independent of the pressure and rpm. Flow rate determination Rotation Control Output Input Clockwise (R) X Y Counter clockwise (L) X Y M3 M4 Rs M1G1 G2 R M2 T1 T2 S N.m 3 [in.lbf] 26.5 2 17.7 40 Y 1 8.85 0 0 X 40-1 -2-8.85-17.7-3 -40-30 -20-10 0 10 20 30 40 Control shaft rotation (degrees) -26.5 The spring return feature in the control unit is not a safety device. 26 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Dimensions Ø 10 h6 +0.000-0.009 +0.000 [dia. 0.39 h6-0.0003 ] 3 x Ø 9 [dia. 0.35] Model Code Restrictor System design Features 90 [3.54] Operating 159 [6.26] Technical specifications 3 [0.12] See page 7 for other dimensions and port characteristics. 105,5 [4.15] Options Controls 45 [1.77] 15 [0.59] See option MI page 44 to add neutral position switch. 10/02/2011 27

PM45 - Variable displacement pump POCLIN HYDRULICS Hydraulic servo control 4 5 1 2 3 4 5 S 6 7 8 9 10 11 The variation in pump displacement is obtained by adjusting the pressure on the M3 and M4 servo control connections by means of a hydraulic proportional joystick (containing pressure reduction valves). The joystick supply can by obtained by taking pressure from the auxiliary pump (G connection). The servo control response time can be adjusted by inserting a restrictor (Rs) on the joystick supply line (from 0,6 to1,2 mm [from 0.02 to 0.05 in]. The servo control operation curve in both control directions goes from 6 to 15 bar [from 87 to 217 PSI]. The adjustment curve of the hydraulic control system has to be wider (from 5 to 16 bar [from 72.5 to 232 PSI]). M6 M5 M1 G1 G2 R C M2 Flow rate determination Rotation Pressure Output Input Clockwise (R) M3 M4 Counter clockwise (L) M3 M4 M3 M4 Rs1 Rs2 T1 T2 S 20 bar [PSI] 290 15 217.5 10 145 5 72.5 0 50 Pump displacement (%) 100 The spring return feature in the control unit is not a safety device. 28 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Dimensions Restrictor 103 [4.05] 112,5 [4.43] Model Code Technical specifications 55 [2.17] 55 [2.17] 24,5[0.96] 24,5 [0.96] 86,5 [3.40] Operating System design Options Controls Features 125 [4.92] 31 [1.22] See page 7 for other dimensions and port characteristics. 10/02/2011 29

PM45 - Variable displacement pump POCLIN HYDRULICS Electrical on-off servo control Control with return spring 4 5 1 2 3 4 5 6 7 8 9 10 11 The reaching of the maximum displacement in a time defined by the restrictors (Rs) which are positioned between the electrovalve and the (T) drain is obtained by the continuous starting of an ON-OFF electrovalve with an open-circuit CETOP 3 connection. If the electro-valve motion is stopped, the pump goes back to 0 position thanks to the servo control springs. The pump can be supplied either without electrovalve (00) or with electrovalve (12, 24 ). Supply voltage without 12V 24V 00 12 24 M3 M4 M3 M4 t a b p Rs M1 G1 T1 T2 S EV2 Rs Rs EV1 Rs M1 G1 G2 R G2 R M2 M2 T1 T2 S Control without return spring 4 5 1 2 3 4 5 6 7 8 9 10 11 The variation in pump displacement is obtained by the energizing of an ON-OFF electrovalve with a closed center CETOP 3 connection. The displacement reached is in relation to the starting time of the electro-valve and to the diameter of the restrictors (Rs) which are placed between the electrovalve and the drain (T). Supply voltage without 12V 24V C00 C12 C24 M3 M4 t a b p Rs M1 G1 T1 T2 S EV2 Rs EV1 G2 R M2 The pump can be supplied either without electrovalve (C00) or with electrovalve (C12, C24). M3 M4 Rs Rs M1 G1 G2 R M2 The servo control is without springs and the setting of the pump at a certain displacement is guaranteed by the closed center of the electrovalve. T1 T2 S Flow rate determination Rotation Control Pressure Output Input Clockwise (R) EV1 EV2 Counter clockwise (L) EV1 EV2 The spring return feature in the control unit is not a safety device. 30 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Dimensions 88,5 [3.48] Model Code Restrictor System design Features Operating Technical specifications p a b t Options Controls 85 [3.35] 159 [6.26] 170,05 [6.70] 00 and C00 EV1 85 [3.35] CETOP 3 EV2 Type of connector: DIN 43650 See page 7 for other dimensions and port characteristics. 10/02/2011 31

PM45 - Variable displacement pump POCLIN HYDRULICS Electro-proportional servo control 4 5 1 2 3 4 5 6 7 8 9 10 11 y means of a potentiometer and a control card, a voltage signal is applied to the proportional electrovalve coils which adjust the pressure of the servo control connected to the pump swashplate. t every position of the potentiometer lever, there is a corresponding swashplate position. The flow rate direction depends on which coil is excited. The adjustment speed can be controlled by ramps installed on the card and by restrictors (Rs) positioned between the electrovalve and the servo control. Supply voltage 12V 24V P12 P24 Flow rate determination Rotation Pressure Output Input Clockwise (R) EP1 EP2 Counter clockwise (L) EP1 EP2 M3 M4 EP2 Rs EP1 Rs M1G1 G2 R M2 T1 T2 S 1300 650 The current must not exceed 1500 m under 12V and 800 m under 24V. Current (m) (12V) 1100 900 700 550 450 350 Current (m) (24V) 500 0 50 Pump displacement (%) 100 250 From 0 to max. displacement: From max. displacement to 0: The spring return feature in the control unit is not a safety device. 32 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Dimensions 144 [5.67] Model Code 132,6 [5.22] Operating System design Technical specifications EP1 EP2 Options Controls 136,6 [5.38] Restrictor 90,8 [3.57] See page 7 for other dimensions and port characteristics. Features 90,8 [3.57] Type of connector: DIN 43650 10/02/2011 33

PM45 - Variable displacement pump POCLIN HYDRULICS Hydraulic automotive control 4 5 1 2 3 4 5 6 7 8 9 10 11 In relation to the input rotation rate, the pump swashplate positioning cylinder is actuated by the pressure of the adjustment valve and a 4/3 electro-hydraulic valve, progressively positioning the swashplate. This provides a continuously variable pump displacement. The direction of the supplied flow is determined by which of the two solenoids is energized. The pilot pressure increases proportionally to the rotation plate. pump displacement increase corresponds to the higher pilot pressure. In case the prime mover is overloaded, the rotation rate decreases and the pilot pressure is reduced causing a pump displacement reduction with a corresponding drop in absorbed power. n "Inching" lever is available to reduce the pilot pressure independently of the pump rotation speed (See option IC page 41). Supply voltage 12V 24V D12 D24 Flow rate determination Rotation Pressure Output Input Clockwise (R) EV1 EV2 Counter clockwise (L) EV1 EV2 M1 G1 D IC G2 R M2 IC= Mechanical inching. See option IC page 41. EV2 EV1 Rs Rs M3 M4 T1 T2 S 34 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Dimensions (with option IC Mechanical inching) 88,5 [3.48] 85 [3.35] 85 [3.35] Model Code EV1 EV2 Restrictor Options Controls 15 [0.59] Features 159 [6.26] 170,05 [6.70] 107 [4.21] 3 [0.12] Technical specifications 74 [2.91] Mechanical inching lever Operating System design 139 [5.47] 3 x Ø 9 [0.35] 45 [1.77] 99 [3.90] 183,75 [7.23] See page 7 for other dimensions and port characteristics. 10/02/2011 35

PM45 - Variable displacement pump POCLIN HYDRULICS Electrico-proportional servo control with feed back 4 5 1 2 3 4 5 6 7 8 9 10 11 y means of a potentiometer and of a control card, a voltage signal is applied to the proportional electro-valve coils which adjust the pressure of the servo control connected to the pump swashplate. t every position of the potentiometer lever, there is a corresponding swashplate position. The flow rate direction depends on which coil is excited. The adjustment speed can be controlled by ramps installed on the card and by restricters positioned between the electro-valve and the servo control. The feed back system permit to maintain costant the displacement of the pump if the pressure change between pump and hydraulic motor. Supply voltage 12V 24V Q12 Q24 EV2 EV1 M6 M5 M1 G1 G2 R C M2 M3 M4 Rs2 Rs1 T1 T2 S 36 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Dimensions 146,5 [5.77] Model Code Restrictor Options Controls Operating Technical specifications EV1 90,8 [3.57] System design Features 153,2 [6.03] 164,55 [6.48] 90,8 [3.57] See page 7 for other dimensions and port characteristics. EV2 10/02/2011 37

PM45 - Variable displacement pump POCLIN HYDRULICS Hydraulic servo control with feed back 4 5 1 2 3 4 5 T 6 7 8 9 10 11 The variation in pump displacement is obtained by adjusting the pressure on the M5 and M6 feed back system connections by means of a hydraulic proportional joystick (containing pressure reduction valves). The joystick supply can by obtained by taking pressure from the auxiliary pump (G connection). The servo control feedback time can be adjusted by inserting a restrictor between the control block and the servo-control piston. The servo control operation curve in both control directions goes from 6 to 15 bar [87 to 218 PSI]. The adjustment curve of the hydraulic control system has to be wider (5 16 bar). The feed-back system between swash plate and servo piston permit to mantain costant the displacement of the pump if change the pressure between pump and hydraulic motor. M6 M5 M1 G1 G2 R C M2 M3 M4 Rs2 Rs1 T1 T2 S 38 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Dimensions Model Code Restrictor Operating Options Controls Features 132 [5.20] Technical specifications M3 M5 System design See page 7 for other dimensions and port characteristics. M6 M4 10/02/2011 39

PM45 - Variable displacement pump POCLIN HYDRULICS 40 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 OPTIONS SE flange ports Model Code 4 5 1 2 3 4 5 6 7 8 9 10 11 FS 174 [6.85] M10 23,8 [0.94] 23,8 [0.94] 12,1 [0.48] 12,1 [0.48] 50,8 [2.00] 50,8 [2.00] Technical specifications Operating Mechanical inching System design For hydraulic automotive control D. n "Inching" lever is available to reduce the pilot pressure independently of the pump rotation speed. See Hydraulic automotive control D page 34. Options Controls Features 37,5 [1.48] 37,5 [1.48] Port Function SE - Services 3/4 flange SE (414 bar [6 000 PSI]) G1/G2 uxiliary 1/4 GS M1/M2 - pressure 1/4 GS M3/M4 Servo control 1/4 GS S Suction 1 GS T1/T2 Drain 3/4 GS R Servo pilot pressure 1/4 GS C Case pressure 1/4 GS 4 5 1 2 3 D12 or D24 4 5 6 7 8 9 10 11 IC 10/02/2011 41

PM45 - Variable displacement pump POCLIN HYDRULICS Filter on pressure line The PM45 pumps can have a pressure filter without clogging indicator (F0) or with clogging indicator (F2). The flow thru the filter is only the flow that entry in the close loop. The filter fitness is of 10 micron. The max. working pressure is 30 bar [435 PSI]. Maximum pressure difference between filter cartridge input and output is 2 bar [29 PSI]. When reaching 2 bar [29 PSI], the cartridge has to be changed. Tightening torque: 35 Nm [309 in.lbf]. 4 5 1 2 3 4 5 6 7 8 9 10 11 F0 Without clogging indicator F2 With clogging indicator M1 G1 G2 M2 M1 G1 G2 M2 NC 2 bar [29 PSI] M6 M5 M6 M5 M3 M4 Rs1 Rs2 M3 M4 Rs1 Rs2 T1 T2 S T1 T2 S M1 G1 33 [1.30] 11,5 [0.45] 85,7 [3.37] 33 [1.30] 11,5 [0.45] G2 M2 11 [0.43] 174 [6.85] Clogging indicator 48,5 [1.91] 231,2 [9.10] 196,5 [7.74] Ø 62 [dia. 2.44] 120,5 [4.74] 154,5 [6.08] 42 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Pressure cut-off valve 4 5 1 2 3 4 5 6 7 8 9 10 11 LP Model Code The function of the cut-off valve is to avoid that the pump absorbed power exceeds the machine engine power. The cut-off valve is connected to and piston pump s high pressure lines and is usually set at 20 to 30 bar [290 to 435 PSI] lower than the maximum relief valve of the closed circuit. The cut-off valve acts on the servo control operating pressure in order to reduce the pump displacement and the adsorbed power. X G1 M1 Technical specifications R 33 [1.30] 11,5 [0.45] 33 [1.30] 11,5 [0.45] Operating Pressure cut-off setting View X G2 C M2 11 [0.43] 11 [0.43] 174 [6.85] M1G1 G2 RC M2 System design EP1 EP2 EP1 0.8 118 M3 M4 Rs2 Rs1 Features EP2 T1 T2 S Options Controls 10/02/2011 43

PM45 - Variable displacement pump POCLIN HYDRULICS Neutral position switch 1 2 3 4 5 6 7 8 9 10 11 4 5 MI For the control (see page 26 Mechanical servo control with feed back) it is possible to obtain a micro switch to avoid the start of the engine if the lever of the control is not in center (zero position). 96,5 [3.80] 159,8 [6.29] 30,8 [1.21] Rs M1 G1 G2 R C M2 M3 M4 T1 T2 S Electrical characteristics Type of connector Deutsch DT04-2P Output NC and NO Cable connections PG 13,2 Max. current 10 Electric load type Resistive Operating temperature C [ F] from -25 to 80 [-13 to 176] Type of protection IP 67 44 10/02/2011

POCLIN HYDRULICS Variable displacement pump - PM45 Flushing valve 4 5 1 2 3 4 5 6 7 8 9 10 11 VS Model Code Inside the pump cover, a purge valve can be fitted with discharge inside the pump casing by means of a calibrated hole. The exchange valve is useful in case the temperature of the oil in the closed circuit is too high. X 33 [1.30] 11,5 [0.45] R G1 M1 Technical specifications 33 [1.30] 11,5 [0.45] G2 Operating C View X 116 [4.57] M3 M4 M2 Rs1 11 [0.43] M6 M5 Rs2 11 [0.43] System design Features Options Controls M1 G1 174 [6.85] G2R C M2 T1 T2 S 10/02/2011 45

PM45 - Variable displacement pump POCLIN HYDRULICS 46 10/02/2011

Thirteen subsidiaries and a worldwide network of more than 150 distributors and partners 10/02/2011 35768D Poclain Hydraulics reserves the right to make any modifications it deems necessary to the products described in this document without prior notification.the information contained in this document must be confirmed by Poclain Hydraulics before any order is submitted. Illustrations are not binding. The Poclain Hydraulics brand is the property of Poclain Hydraulics S.. More information on