MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

Similar documents
MODEL CMS INSTALLATION INSTRUCTIONS A. INTRODUCTION 1. USAGE 2 2. HOW IT OPERATES 2 B. SPECIFICATIONS 1. ELECTRICAL 3 2.

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

PRODUCT INFORMATION BULLETIN

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

Operations Manual. Zero Speed Switch Sensor Model ZS09P

BMRX Series Rotary Level Indicator

RP-4000 Reserve Power Control

MAXIGARD A2000 SPEED SWITCH. Introduction

System 350 P352AB Electronic Pressure Control Series

Model 550 Series Vibration Switches

PRO REMOTE Series CAPACITANCE PROBE

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

POSITION TRANSMITTERS

EC-3000/3400 Solid State Rotary Cam Limit Switch Installation/Operation Manual

GE Sensing & Inspection Technologies

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

2006 Series Geared Rotary Limit Switches

RESISTIVITY MONITOR/CONTROLLERS

DC3N Non-Regenerative DC Drives

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Super-Safe-Plus Roto-Bin-Dicator

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

SM-1000 SERIES ROTARY ACTUATORS

CONTROL FEATURES AVAILABLE OPTIONS

Carbon Monoxide Transmitter

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

Table of Contents General Information Specifications Dimensions Programming Instructions Installation Parts List Input Devices

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

Combined Ventilation Controller RVWS-T-224HA

2000 Series Geared Rotary Limit Switches

CM3000 SIGNAL TRANSMITTER. Introduction. The MAXIGARD CM3000 is designed to convert shaft speed into a 4/20 ma or 0-10 VDC analog output signal.

Installation Instructions

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

CONTROL BOX. Wiring the control box into the vehicle. +12V

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

Model 116 DPI Switch Installation and Operating Instructions

Application Engineering

Application Engineering

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

Vibralert Mechanical Switch Model 5550

Assembly Numbers & Spare Parts

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

MA-5200 Series MA-5300 Series

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

MODEL 10LH SPECIFICATION

Boston Gear Ratiotrol

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

AC Motor Brakes. General Information. Features. Add-On Brakes. Spring Applied Power-Off Operation. Motor Brake Coil Current. Mounting.

TS1 SMARTBOB REMOTE UNIT. INSTALLATION and OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

5001TCP SPEED CONTROLLER

SERIES 2600/2610 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-5 HP)

I-BFV.KIT Butterfly Valve Gear Operator Replacement

ROTARY Point Level Measurement for Inventory Control

5001TCP SPEED CONTROLLER

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

MODEL JH JACKSHAFT INDUSTRIAL DOOR OPERATOR INSTALLATION MANUAL. OPERATOR SPECIALTY COMPANY, INC. P.O. Box 128 Casnovia, MI 49318

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

SECTION MOTOR REQUIREMENTS for HVAC

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Troubleshooting Bosch Proportional Valves

Avtron Model M3. Rotary Pulse Generator. Easy to Install Cost Effective Rugged Construction High Resolution Versatile

DIGITAL GLYCOL FEEDER

SUB-FHP AC GEARMOTORS PARALLEL SHAFT GEARMOTORS

TRAC-3 TENSION READOUT AND CONTROL

RF Point Level Control with Sensor Monitor

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

STEADYWEB TENSION CONTROLLER Data Sheet

Installation Instructions

17429X.00 SERIES MODELS:

Position Transmitters. Instruction Manual. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

KENCO ENGINEERING COMPANY

1.0 Features and Description

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

INSTALLATION & OPERATION MANUAL

IOM. LP-100 & LP-200 Pulse Point TM Installation & Operation Manual

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

Model Combustible Gas Sample Draw Detector Head Operator s Manual

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

Installation & Operation Manual

Installation, Operation and Maintenance Manual

1980 Rotating Cam Limit Switches. Ordering Guide & Technical Information

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

CP (Vdc) CP (Milliamp) CP (Slidewire)

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved

Bray Series 70 Electric Actuator. Basic Product/Sales School

Sentry Battery Charger. Installation and Operations Manual Section 75

Boston Gear Ratiotrol

DMC mA Positioner

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

Horizontal Circuit Switchers

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Horizontal Circuit Switchers

Transcription:

CONVEYOR COMPONENTS COMPANY 130 Seltzer Road, PO Box 167 Croswell, MI 48422 USA PHONE: (810) 679-4211 TOLL FREE (800) 233-3233 FAX: (810) 679-4510 Email: info@conveyorcomponents.com http://www.conveyorcomponents.com MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION The Model MSD is both a motion-sensing control and a tachometer. It has a separate rugged sensor enclosed in a heavy-duty cast aluminum (or iron) housing. Electronics are contained in a separate remote control unit away from dirt, vibration, and temperature fluctuations. The MSD is a dual speed control with two set points permitting it to indicate two under-speed points, two over-speed points, or one each under-speed and over-speed point. At the same time, the control unit displays the actual shaft RPM on the digital readout. Operation: A precision metal disc with slots on its periphery is used in the sensor to generate electronic pulses as the disc rotates past an infra-red light source. These pulses are transmitted to the electronics in the control unit where the signal is analyzed and the relays are activated or deactivated at preset signal speeds. The electronic components of the control unit are designed to permit two signal set points. Field adjustment of the two signal set points is easily accomplished by a series of digital switches on the control panel. Technical Information: MSD-1 Sensor: Input: 12 VDC from the control unit Output: 12 VDC square wave to control unit Operating Temperature Range: -50 F to +150 F Maximum Speed Limit: 1000 RPM Shaft Load: 125 lbs. radial, 100 lbs. end thrust Rotation: Clockwise or Counter-clockwise Drive Torque: 1 inch-pound Shaft: 5/8 dia. x 1 ¼ long stainless steel Enclosure: NEMA 4 and NEMA 7, 9 cast aluminum or optional cast iron Bearings: Permanently lubricated and sealed for life ball bearings MSD-2 Control Unit: Power Input: Signal Input: Output: Operating Temperature Range: Reading Accuracy: Operating Range: Signal Speed Range: Alarm Set Accuracy: Enclosure: 120 or 240 VAC, 50/60 Hz, 50 Watts Optional 240 VAC, 50 Watts Optional 24 V AC or DC, 50 Watts 12 VDC square wave from sensor 2 sets DPDT rated 10 amps resistive at 125/250 VAC; 10 amps resistive at 30 VDC and ¼ HP at 125 VAC, 60 Hz. -30 F to +140 F ±1 RPM 0-1000 RPM 0-1000 RPM ±1 RPM NEMA 1 panel mount or NEMA 12 and 4 J.I.C. surface mount I0050004revA.DOC Copyright Conveyor Components Co. 2004 1 OF 6

Installation and Wiring: Mount the MSD-1 sensor in any position on a smooth, flat surface using ¼ mounting bolts and lock washers. If vibration is extreme, dowel two mounting holes and use bolts in the others. The sensor shaft must be in line or parallel with the drive shaft. For conduit installation, use only hubs of suitable sizes that are UL/CSA approved for WATERTIGHT use. Install per the hub manufacturer s instructions. Be sure the location selected will provide adequate wire bending space. Use two conductor shielded cable (such as our MSD-14 or Belden 8760) to connect the MSD-2 control unit with the MSD-1 sensor. A maximum of 500 ft can be used. The control unit contains two DPDT relays and corresponding output contacts. Output relays energize under normal operation and de-energize in the event of alarm or power failure. Figure 1: Relay Logic Figure 2: Setpoints Note: relays are labeled in their non-alarmed state on the control unit. Non-Alarm State Relay Engergized Normal Operation Alarm State or Power Failure Relay Not Engergized (De-engergized) N.O. 2 C. 2 N.C. 2 N.O. 1 C. 1 N.C. 1 N.O. 2 C. 2 N.C. 2 N.O. 1 C. 1 N.C. 1 OVER SPEED ALARM SET UNDER SPEED ALARM SET MSD-701=UNDER, UNDER SPEED EXAMPLE: MSD-702=OVER, OVER SPEED OVER SPEED SETTING = 1000 RPM MSD-703=OVER, UNDER SPEED UNDER SPEED SETTING = 500 RPM MSD-700-BW = OVER SPEED, ZERO Factory Assistance: If assistance is needed to locate difficulties with a unit or you would like information about alternate control devices, please call the factory at 1-800-233-3233 or via e-mail at info@conveyorcomponents.com. To help solve a problem quickly, please have as much of the following information as possible when you make your call: Model Number Date Purchased Brief Application Information Brief Description of the Problem. EQUIPMENT SHIPPED BACK TO THE FACTORY WITHOUT PROPER AUTHORIZATION WILL BE REFUSED AND RETURNED AT THE SHIPPER S EXPENSE. I0050004revA.DOC Copyright Conveyor Components Co. 2004 2 OF 6

Model MSD Troubleshooting Tips Display is blank. a. Verify input power to controller. b. Verify correct connections to sensor. Interchanging connections can short the power supply, which will shut down automatically. Display reads 0 rpm. a. Using an old style sensor with a newer version controller. Replace sensor with new style version. b. Incorrect connections to sensor. Verify pin 1 to 1, 2 to 2, 3 to 3. Verify pin 3 is shield on both ends. Relays do not trip when set point is reached. a. Set the digital rotary switches with the appropriate trip speed (thousandths, hundredths, tenths, ones). b. The over speed set point MUST be set higher than the under speed set point, even if unused. c. Verify that the appropriate relay is being used. d. Verify the relay wiring, the relays are labeled in their non-alarmed state. e. The relays are dry, unpowered relays. Verify that the COM is sourced with appropriate voltage. RPM display is erratic or inconsistent. a. Verify that Belden 8760 or similar shielded cable is being used between sensor and controller. b. Verify that the sensor cable is 500 feet or less. c. Verify that the sensor cable is enclosed in a metal conduit with out any power carrying cabling. d. Verify the controller is not mounted near any Variable Frequency Drives. RPM display does not match the actual conveyor speed (in RPM). Adjust RPM calibration pot located on the front of the display board near the last 7-segment display. Note: Model MSD-700BW should read ½ actual sensor speed. I0050004revA.DOC Copyright Conveyor Components Co. 2004 3 OF 6

Figure 2: Sensor dimensions Figure 3: Panel mount control dimensions CONTROLLER MOUNTING: CUT OUT HOLE DIMENSIONS 7.5" W X 6" H [114 X 152mm]. FRONT VIEW SIDE VIEW I0050004revA.DOC Copyright Conveyor Components Co. 2004 4 OF 6

Figure 4: Chassis mount control dimensions Figure 5: Sensor and control wiring I0050004revA.DOC Copyright Conveyor Components Co. 2004 5 OF 6

Figure 6: Use of flexible coupling Figure 7: Offset mount using spur gears Figure 8: Offset mounting using belt / chain drive I0050004revA.DOC Copyright Conveyor Components Co. 2004 6 OF 6

Figure 9: Figure 10: Typical mounting Figure 11: Bracket chart I0050004revA.DOC Copyright Conveyor Components Co. 2004 7 OF 6