X-BT-ER stainless steel threaded studs for electrical connections

Similar documents
Hilti Product Technical Guide Supplement X-BT-ER Electrical Connection Systems

The following pages are an excerpt from the North American Product Technical Guide, Volume 1: Direct Fastening Technical Guide, Edition 18.

S-BT screw-in stainless steel and carbon steel threaded studs

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Special Purpose Fuses

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

Printview: 2-conductor ground terminal block - Item No.:

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Pressure and temperature controls, Type CAS

The new SH200 MCBs can be used in domestic, commercial and industrial applications for protection against over-current and short circuit.

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Technical data for manual motor starters Type MS325

power cable accessories

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

Temperature Sensors Types MBT 5250, MBT 5260 and MBT 5252

MS General Information Extended Product Type: MS

» Fermentation and storage tank base tank FS-MO stacking tank AS-MO

3EQ Composite Housed Surge Arresters

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...

20 HUBER+SUHNER RADOX SOLAR

Electrical connection systems

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

Datasheet. Pitch Motor PMSM SP260B8

Phase + Neutral, neutral on left side

Datasheet. Pitch Motor PMSM SP190C8

Datasheet. Pitch Motor PMSM SP190F8

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

Double-deck PCB terminal strip; 2 solder pins, in line; 4x2-pole; pin spacing 10 mm / in

Phase + Neutral, neutral on right side

Pressure transmitter for marine applications MBS 3100 and MBS 3150

FISCHER FREEDOM TM SERIES

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

SERIES 54 Inductive Proximity Sensor

C60H-DC C curve. Catalogue numbers

BlueLine Cables for Shipbuilding

Pressure transmitter for marine applications MBS 33M

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Chemical resistance Accidental

POWER CAPACITORS. Cylindrical capacitor standard duty

Voltage limiting device HVL

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Transformer bushings, type GOA 250. Installation and maintenance guide


Medium voltage products. KEVCD A combined current and voltage sensor Instructions for installation, use and maintenance

Cylinders Series 61 - Aluminium profile

Thermal-Magnetic Circuit Breaker 201/-WA

CONFIGURATION OF CABLE SUPPORT SYSTEMs

Pressure switch and Thermostat Type CAS

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY

3EK7 Distribution Class Surge Arresters. Answers for energy.

Shielded surge arresters

Essential equipment for all your requirements

Control Circuit Protection

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

Power and Cooling. Chassis Power System

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Distribution terminal block; 3 x CAGE CLAMP connection 10 mm²; 1 x screw-clamp connection 35 mm²

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

Magnetic Overcurrent Circuit Breaker

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Transformer bushings, type GOH. Technical guide

Strip type fuse-switch-disconnectors

Shipbuilding solutions

Data sheet chainflex CFSOFT1

EPN/EPNCR Applications. Features

a Nexans company Medium voltage symmetrical separable connectors - Interface C -

X-M 6, X-W6, X-F 7, X-M 8, M 10, W 10 Threaded Studs for Concrete

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

NABOO A ++ A + A. EU Regulation 874/ Illumination equipment energy classes. Naboo. .0 Inox. Recessed ground fitting

Synergy EN product information

3EK7 Distribution Class Surge Arresters. Answers for energy.

Solid State Relays contactor with Integrated Fuse Type RGC1F

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

Accessories. Introduction. Cable Hangers LINE PRODUCTS TRANSMISSION

Voltage limiting device HVL

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

DX³ RCCBs - ID 4P up to 100 A

h2* linear fall up to 20 m, stepped fall, without fall Loading classes: A 15, B 125, C 250 to EN 1433

Load and Motor Switches, Load-Break Switches Series 8549

TFS / KFSU: Isolating spark gaps with plastic coating and 2 connections (Rd 10 mm) made of stainless steel

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

KATKO Safety Switches:

Aluminium profile. Double-acting, magnetic, cushioned ø 32, 40, 50, 63, 80, 100 mm

Single and double-acting, magnetic, cushioned Standard, low friction, low temperatures and tandem versions ø 32, 40, 50, 63, 80, 100, 125mm

Transcription:

stainless steel threaded studs for electrical connections Product data X-BT-ER Dimensions 1 2 3 1 7 2 M8 Ø 4. [0.177"] 1 M10/ W10 3 Ø 12 [0.472"] 24 [0.94"] 4 4 31.3 [1.232"] [0.18"] 7 M6/ W6 3 Ø 4. [0.177"] Ø 4. [0.177"] Ø 12 [0.472"] 6 4 [0.18"] 2 [0.079"] General information Material specifications 1 Shank: CR 00 (CrNiMo alloy) S31803 (1.4462) Recommended fastening tools DX 31-BT See X-BT-ER fastener program in the next pages and tools and equipment chapter for more details. Approvals for X-BT-ER stainless steel threaded studs for electrical connections UL, ABS, LR, DNV-GL, BV Ø 12 [0.472"] 24 [0.94"] 4 31.3 [1.232"] 6 2.4 [0.094"] 6 Equivalent to A4 / AISI grade 316 material 2 Threaded sleeve: XCrNiMo 17-12-2+2H, 1.4401 3 SN washer: S 3163 (X2CrNiMo 17-12-2, 1.4404) 4 Sealing washer: Elastomer, black * * Resistant to UV, salt water, water, ozone, oils, etc. Nuts A4 / AISI grade 316 material 6 Lock washers A4 / AISI grade 316 material 7 Guide Sleeve Plastic R 20 [0.787"] 4 31.3 [1.232"] 1.6 [0.062"] Applications Examples Functional and protective bonding in pipe (Outer diameter of installed surface 10mm) Protective bonding circuit - Double point connection 12/2017 www.hilti.group 231

Functional Bonding and Terminal connection in a circuit For low permanent current due to static charge built up in pipes or for low permanent current when closing an electrical circuit Single point connection Protective bonding circuit Single point connection Maximum allowable permanent current = 40A Note: Recommended connected cable size (tested to 40A) according to IEC/ EN 60204-1: 10mm 2 copper ( 8AWG). Fastening of thicker cable is acceptable provided the maximum permanent current of 40A is not exceeded and the provisions on cable lug thickness are observed. For discharging short circuit current while protecting electrical equipment or earth / ground or bonded cable trays and ladders Max. short circuit current for period of 1s = 120A Note: Recommended connected cable size (tested to 120A for 1s) following IEC/EN 60947-7-2: 10mm 2 copper ( 8AWG). Fastening of thicker cable is acceptable provided the maximum current of 120A for a period of 1 second is not exceeded and the provisions on cable lug thickness are observed. Recommended connected cable size (tested to 70A for 4s) according to UL 467: 10AWG Double point connection Max. short circuit current for period of 1s = 1800A Note: Recommended connected cable size (tested to 1800A for 1s) following IEC/EN 60947-7-2: 16mm 2 copper ( 6AWG). Fastening of thicker cable is acceptable provided the maximum current of 1800A for a period of 1 second is not exceeded and the provisions on cable lug thickness are observed. 232 www.hilti.group 12/2017

Lightning protection For high temporary current due to lightning. Single point connection Maximum current (According to EN0164-1 and EN 0164-1/prA:200): 0kA for 2ms When one nut is utilized and cable lug is in contact with base material. Cable lug must be in direct contact with non-coated base material. Extra M10/W10 SS washer to be used and installed between lock washer and cable lug. Base material must not contact the X-BT-ER SN washer, lock washer and nut. Cable lug thickness = 2mm to 12mm. Cable lug hole diameter 13mm. Max. tightening torque = 8Nm. Maximum tested current: 100kA for 2ms Application requirements Thickness of base material Thickness of cable lug Base material corrosion protection layer Thickness of base material corrosion protection layer 0.4mm. For thicker coatings, please contact Hilti. X-BT-ER M10/W10 t cl 3mm (0.12 ) X-BT-ER M8 X-BT-ER M6/W6 t cl 7mm (0.28 ) 12/2017 www.hilti.group 233

Spacing and edge distances Edge distance: 6 mm > 6 [0.236"] > 6 [0.236"] > 1 > 6 > 1 [0.91"] [0.236"] [0.91"] Spacing: 1 mm > 6 > 1 [0.236"] [0.91"] > 1 [0.91"] > 8mm [/16"] > 8mm [/16"] Corrosion information The corrosion resistance of Hilti CR00 and S31803 stainless steel material is equivalent to AISI 316 (A4) steel grade. Application limit t II 8 mm [/16 ] No through penetration No limits with regards to steel strength Fastener selection and system recommendation Fastener program Tool Fastener Guide Designation Item no. designation designation 2103094 DX 31-BT BT FG M1024 2103093 DX 31-BT BT FG W1024 210309 DX 31-BT BT FG M1024 210727 DX 31-BT BT FG M1024 2103096 DX 31-BT BT FG W1024 Cartridge selection and tool energy setting 6.8/11 M high precision brown cartridge Fine adjustment by installation tests on site 234 www.hilti.group 12/2017

Fastening quality assurance Fastening inspection hnvs X-BT-ER M/W10, X-BT-ER M8 and X-BT-ER M/W6 h NVS = 2.7 26.8 mm = 1.01 1.0 Installation for electrical connections Single point connection for all X-BT-ER Double point connection only for X-BT-ER M6/W6 and X-BT-ER M8 12/2017 www.hilti.group 23

Torque recommendation for X-BT-ER Hold the bottom nut with a spanner while tightening the upper nut. Tightening torque: Min. 8 Nm Max. 20 Nm These are abbreviated instructions which may vary by application. ALWAYS review/follow the instructions accompanying the product. 236 www.hilti.group 12/2017