Data Sheet 3.03 Issue D

Similar documents
Data Sheet 3.01 Issue C

Data Sheet 3.11 Issue F

Model VKFD28 Flexible Sprinkler Drops (LPCB Approved) Installation Manual. January 2016 Form No. F_ Rev 16.1

I-VICFLEX.AB7 VicFlex Sprinkler Fittings for Ceiling Suspension Systems STYLE AB7

I-VICFLEX.AB5. Victaulic VicFlex Style AB5 Sprinkler Fitting for Wood or Metal Joists/Studs and CD Profile (60 mm) Channel Ceiling Systems WARNING

I-VICFLEX.AB11. Victaulic VicFlex Style AB11 Low-Profile Sprinkler Fitting for Suspended Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

Flexible Sprinkler Connector Braided & Unbraided

I-VICFLEX.AB1/AB2/AB10

KOFULSO /Easyflex flexibles sprinklers drop distributed by

Flexible Sprinkler Connections

PROFLEX FLEXIBLE SPRINKLER HOSES (PAGE 1/5)

INSTALLATION INSTRUCTIONS FOR DECK TUB SETS with HAND SHOWER Valves Numbered: &

Listings and Approvals. G5 QR Gasket culus QR G5 SR Gasket culus, FM SR G5

SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems.

FRAME STYLE SPRAY NOZZLES TECHNICAL DATA

Instructions for Installation, Operation, Care and Maintenance

GW THERMOCOOL NOZZLE STRUCTURAL STEEL PROTECTION

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

TECHNICAL DATA OBSOLETE

Model F1 Model F1 Recessed Standard Response Sprinklers

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

model E Spray nozzles vk810 - vk817

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less.

Victaulic Fittings, Couplings, Valves & Sprinkler Heads for the Fire Sprinkler Market Keeping the art of distribution simple

Fire Protection Systems

TECHNICAL DATA SPRINKLER ESCUTCHEONS

B21 Series BASOTROL Gas Valve

Directional Spray Nozzles, Open, with Strainers High Velocity General Description

TECHNICAL DATA VK810 (65 ) VK811 (80 ) VK812 (95 ) VK813 (110 )

Features 1. Differential Latch-type, lightweight, dependable

SOLID CONE SPRAY NOZZLES TECHNICAL DATA

Data Sheet 11.1 Issue A

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Instructions for Installation, Operation, Care and Maintenance

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

ALARM CHECK VALVE 3", 4" & 6" MODEL H-1 FLANGE/FLANGE 3" & 4" MODEL H-2 GROOVE/GROOVE 3", 4" & 6" MODEL H-3 FLANGE/GROOVE

Model RM-1 Riser Manifold Commercial and Residential General Description

FIRE PROTECTION PRODUCTS

Data Sheet 11.2 Issue B

Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of.05 gpm/ft 2

mirage standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6)

Worldwide Contacts.

Easy Riser swing check valve Models E-1 & F-1

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

Wet pipe low flow foam/water manifold system

Grinnell Grooved Fire Protection Products Grooved Fittings

Technical Data. UL Listing is based on the following criteria:

argco.com

with the specific application. Always read and understand the installation

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

Male stud fittings. Male stud elbow. Fluid... Working pressure... Vacuum level... Rated temperature...

Installation Instruction

TECHNICAL DATA. Trimpac 244a. April 15, 2011

Instructions for Installation, Operation, Care and Maintenance

TIDALFLUX 2300 F Quick Start

SPEAKMAN. SE-675 Installation, Operation, and Maintenance Instructions SAFE-T-ZONE EMERGENCY SHOWER AND EYE/FACE WASH

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

Instruction Manual. Single Acting Hydraulic Aluminium Pull Cylinders RAP Series. Maximum Operating Pressure 700 bar

Model DDX Deluge Valve 8 (200mm) Features

Type D3S PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP804

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Inverted High Pressure Fluid Filters

DELUGE VALVE DATA SHEET

FAX

TECHNICAL DATA. Trimpac 249a. September 16, 2013

DT34 and DT54 Series Rotary Sprinklers

OWNER S MANUAL. ROTARY SURFACE CLEANER Models 105C, 105F, 105CW, & 105FW. Revision 2.01

SECTION COMPRESSED-AIR PIPING FOR LABORATORY FACILITIES

SAFETY MANUAL READ FIRST!

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

Section H Spray Guns. Table of Contents

VNIV.EX454 Sprinklers, Automatic and Open. Sprinklers, Automatic and Open

4 Installation Guidelines

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK. This work covers part of outcome 2 of the Edexcel standard module:

Technical Information PTFE-Hoses

Supplementary instructions. Air cooling - FIBERTRAC 31. Active air cooling system for radiation-based sensors. Document ID: 50339

Paint/Solvent/Dump Valve and Flow-Through Valve

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

Miniature Regulator Series ARJ310

Standard Specifications

P239-1 Supply Pumper Instructions

Instruction Manual. Maximum Operating Pressure 700 bar

One Million Raindrops by Senju Sprinkler. Product Brochure

Micro24 TM Hose & Tube System

PRODUCT SAFETY NOTICE

Data Sheet Issue E

Signet 2517 Brass Paddlewheel Flow Sensor * *

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

Grooved Piping System for Fire Protection Services

CHESTERTON FLOW GUARDIAN S50 AND SP50 SINGLE FLOWMETER INSTALLATION INSTRUCTIONS

A. This Section includes natural gas piping, specialties, and accessories within the building.

Supplementary instructions. Water cooling - MINITRAC 31. Active water cooling system for radiationbased. Document ID: 48522

TECHNICAL DATA OBSOLETE

DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

MODEL: HV-AS & HV-BS TECHNICAL DATA : MAINTENANCE DESCRIPTION PRESSURE (3/4 NPT OPTIONAL)

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

TECHNICAL DATA. Table Standard Materials

GENERAL INSTALLATION MANUAL

Transcription:

Description Rapidrop Flexible Sprinkler Hose connects the sprinkler to the branch pipe. The flexible stainless steel hose and fittings are particularly suited for use in suspended ceiling applications. The Rapidrop assembly comes with a stainless steel flexible hose, a branch line connection inlet nipple, a sprinkler reducer and a set of fixing brackets. Flexible stainless steel hoses are available in lengths 0.78-0.25m (31 100 ) with either ½ or ¾ NPT / BSPT threaded outlets. Technical Details Max. Working Pressure 12 bar / 175 PSI (UL) 16 bar / 232 PSI (LPCB) Max. Ambient Temperature 107 C / 225 F Min. Bend Radius of Flex. Hose Connection to Branch Line (Inlet) 100mm / 4 (UL) 75mm / 3 (LPCB,) - R1 (1 BSPT) - R1-1/4 (1-1/4 BSPT) - 1 NPT Connection to the Sprinkler (Outlet) - Rc½ (1/2 BSPT) - Rc¾ (3/4 BSPT) - 1/2 NPT - 3/4 NPT - Rc½ (½ BSPT) External Thread - ½ NPT External Thread Rapidrop flexible hose is available in 3 configurations:, with inlets and outlets separate or preassembled with the hose, depending on customer requirements. Model SP Material Specification Description Material Flexible AISI 304 Nut SS400 Zinc plated Isolation ring Nylon 66 Seal NBR Outlet Reducer Carbon Steel Zinc Plated Inlet Nipple Carbon Steel Zinc Plated Model SPN Centre Bracket A Side Bracket B Square Bar Pressure Loss Data Model Model SPW Nominal Hose Assembly length Rated Working Pressure bar PSI A 1/2 outlet UL 1 Schedule 40 Pipe Equivalent Length B 3/4 outlet LPCB DN 25 (33.7x2.6mm) m/in. UL LPCB m / ft. m / ft. m Max Number of 90 Bends (UL) UL LPCB Rapidrop SP-1S 0.7 / 27 5.5 / 18 9.8 / 32 5.1 2 3 Rapidrop SP-1 0.78 / 31 8.2 / 27 10.1 / 33 6.0 2 3 Rapidrop SP-2S 1.0 / 39 12 13.4 / 44 14.6 / 48 8.5 3 3 Rapidrop SP-2 1.2 / 48 175 16 16.2 / 53 16.8 / 55 11.0 3 3 Rapidrop SP-3 1.5 / 60 232 20.7 / 68 19.2 / 63 14.2 3 3 Rapidrop SP-4 1.8 / 72 22.3 / 73 23.2 / 76 18.2 3 3 Rapidrop SP-5* 2.5 / 100 - - - 25.2 3 3 Rapidrop SP-6* 3.2 / 125 - - - 32.5 3 3 *Only LPCB approved w: www.rapidrop.com Page 1 of 5 reserves the right to change the design, materials and specifications without notice to continue product development

Important Installation Information Rapidrop Flexible Sprinkler Hose must only be installed by an appropriately qualified person (e.g. LPS 1048 or equivalent) in accordance with requirements of the local authority having jurisdiction. Deviations from these standards will void any warranty. Alterations to Rapidrop products will void any warranty. Rapidrop Flexible Sprinkler Hose, brackets and fittings must not be intermixed with other manufacturer s products. The flexible stainless steel hose should NOT be installed through heating ducts and fire compartments, therefore not to be used with penetration seals, fire stopping cavity barriers, and anything further indicated by approval bodies and sprinkler rules. Rapidrop Flexible Sprinkler Hose is designed for use only in wet sprinkler systems, it should not be installed in dry, alternate or deluge systems. The flexible stainless steel hose should only be installed inside buildings and protected from freezing temperatures. Flexible stainless steel hose and fittings have limited flexibility and are intended only to be installed with bends at their respective minimum bend radii. Where required by the Authority Having Jurisdiction a Rapidrop Minimum Radius Indicator must be fitted to each and all bends which exceed 45 degrees. If the bend exceeds 90 degrees two Minimum Radius Indicators are to be used adjacent. It is the responsibility of the installing contractor to include a copy of this document in the sprinkler system installation, operating and maintenance manual. The flexible stainless steel hose should not be bent within 65 mm (2 1/2 inches) of its connection nuts. 65mm (2 1/2") MIN It responsibility of the system designer to verify suitability for use of chemical exposure, water additives, temperature, UV exposure. If in doubt contact the manufacturer. System designer or responsible person should check with the Rapidrop sales representative that the flexible hose meets the local water regulations. The flexible hose should not be bent or manipulated when pressurized. Hose connections should not be tightened or adjusted when system is pressurised. Hose connections should not be tightened by rotating the nipple or reducer as it may result in damage to the seal. The owner is responsible for maintaining the fire protection system in proper operating condition. Flexible hose to be inspected and maintained during routine sprinkler system inspections by a qualified inspection service in accordance with national codes/requirements. For further details and technical support please contact your Rapidrop sales representative. To avoid damaging the seal flexible hose shouldn t be left hanging without support once mounted to the main pipe. Failure to follow these instructions could cause improper sprinkler operation, resulting in serious personal injury and/or property damage. w: www.rapidrop.com Page 2 of 5 reserves the right to change the design, materials and specifications without notice to continue product development

Installation Instructions BRANCH PIPE CONNECTION NUT INLET NIPPLE FLEXIBLE HOSE B SIDE SQUARE BAR CEILING TILE OUTLET REDUCER SPRINKLER A CENTER B SIDE MAIN RUNNER 1. Install the Inlet Nipple in the Branch Pipe outlet using the normal sealing and tightening methods for connecting pipe threads. Tighten firmly with a pipe wrench for leak proof connection. For SPW this inlet nipple is permanently fixed to the flexible hose and care must be taken not to twist the hose or use it as a lever when tightening in the nipple. 2. Remove plastic Protecting Cap from one end of the flexible hose, check that the black rubber seal is in place and connect the Outlet Reducer (M33 x 1.5 thread end) to that end. To prevent reducer from turning, securely hold in place whilst tightening the hose nut. Tighten to a torque of 20 Nm/15 ft-lbs. Do not exceed the specified torque. Do not use joint compound or PTFE tape on the M33 threads. For SPN and SPW the outlet reducer is permanently fixed to the flexible hose. w: www.rapidrop.com Page 3 of 5 reserves the right to change the design, materials and specifications without notice to continue product development

3. Remove plastic Protecting Cap from the other end of the flexible hose, check that the black rubber Seal is in place and connect that end to the inlet nipple on the range pipe and tighten the nut to a torque of 20 Nm/15 ft-lbs). 6. Attach square bar to the side B brackets, tighten the top screws. 4. Bend the flexible hose to achieve the required routing maintaining the minimum bend radius and position the reducer for sprinkler location. When bending the hose allow 65mm of straight hose from the nut, ensure there are no kinks and use the Rapidrop Minimum Radius Indicator if required by Authority having Jurisdiction. 5. Attach side B Brackets to the main runners of the suspended ceiling using screws provided. Lightly tighten side screws to hold brackets on the ceiling grid rails. 7. Slide A centre bracket onto the square bar, mount the outlet reducer through the A centre bracket and lightly tighten the nut. Adjust location of the centre bracket and the side B brackets until desired location of the outlet reducer is achieved. Firmly secure the side B brackets by tightening the screws to a torque of 5 Nm/4 ft-lbs. The Rapidrop Flexible Hose assembly must be fixed to full height cross tees of the suspended ceiling system using support bar and brackets supplied. The Rapidrop Flexible Hose end B Brackets are not compatible with reduced height or lightweight cross tees. If there are no full height cross tees available, Rapidrop Flexible Hose assembly must be fixed to the Main Runners of the suspended ceiling system. As the Main Runners are usually spaced at 1,200mm this method requires a longer support bar which is available. Various types of B Brackets are available to suit the suspended ceiling Cross Tees and Main Runners, with heights to suit both spray pendent sprinklers with escutcheons and concealed sprinklers. Do not over tighten bracket screws. The reducer (Outlet) must be located securely to prevent movement relative to the ceiling resulting from the system being pressurized, from sprinkler operation and from discharge of water if the sprinkler operates as the result of a fire. The fixing must also resist torsional forces which result from a sprinkler being installed in the reducer. Rapidrop Flexible Hoses longer than 1,6m must have one intermediate support direct from the building structure. This support must be located not more than 1.6m (measured along the route of the flexible) from the sprinkler connection. As the Rapidrop flexible is stainless steel, insulation between the support hanger and the corrugated flexible must be provided to prevent direct metal to metal contact. w: www.rapidrop.com Page 4 of 5 reserves the right to change the design, materials and specifications without notice to continue product development

8. Apply a non-hardening pipe joint compound or PTFE tape to the male thread of the sprinkler head and install in the Outlet Reducer according to the sprinkler head manufacturer s instructions, using the wrench supplied by the manufacturer. When installing the sprinkler head with a two piece escutcheon, the inner piece should be mounted on the thread of the sprinkler head before attaching to the reducer. 9. Adjust height of the Outlet Reducer until desired location of the sprinkler is achieved. Firmly secure the A Centre Bracket by tightening the screws to a torque of 5 Nm/4 ft-lbs). 10. After installation is complete, test the sprinkler system for leaks in accordance with Authority Having Jurisdiction. It is advised to not leave the sprinkler system drained for long periods. w: www.rapidrop.com Page 5 of 5 reserves the right to change the design, materials and specifications without notice to continue product development