SmartPro Medical-Grade UPS, Line Interactive, Lithium Battery, 6 Outlets - 230V, 1kVA, 750W, Full Isolation

Similar documents
SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets

MODEL NUMBER: APS3636VR

MODEL NUMBER: APS2012

MODEL NUMBER: APS2448UL

MODEL NUMBER: APS2424

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

2400W APS INT Series 24VDC 230V Inverter/Charger with Auto-Transfer Switching, Hardwired

MODEL NUMBER: APS750. Highlights. Package Includes. Description

3000W APS X Series 24VDC 230V Inverter/Charger with Pure Sine-Wave Output, Hardwired

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

PowerVerter 750W RV Inverter/Charger with Hardwire Input/Output

Model #: APS3636VR. 36V DC or 120V AC input; 120V AC output (hardwired)

Model #: APS V DC or 120V AC input; 120V AC output (hardwired) Auto Transfer Switching option for battery backup / UPS operation

Model #: RV1012ULHW. 12V DC or 120V AC input; 120V AC output (hardwired)

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Installation and Operation Manual Back-UPS BR800/1100CI-IN

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Retrofit Kit 1 OM.qxd 12/7/ :06 AM Page 1. Owner s Manual. Medical-Grade Mobile Power Retrofit Kit Model #: HCRK-1

2 Uninterruptible Power Systems

Uninterruptible Power Supplies

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Uninterruptible Power Systems

Installation and Operation Back-UPS BX550CI-CN

3 Uninterruptible Power Systems

Uninterruptible Power System

3 Uninterruptible Power Systems

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

3 Uninterruptible Power Systems

Aurora Single Phase Emergency Lighting Inverters

Limousin II User Manual

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Up to 98% efficient under full load Similar runtimes to the previous 3u model

Sola/Hevi-Duty S3K Series Mini-Tower UPS

CP900EPFCLCD User s Manual K

3 Uninterruptible Power Systems

Installation and Operation Manual Back-UPS BX1100CI-CN

3 Uninterruptible Power Systems

Installation and Operation Manual Back-UPS BR1000-CH

Back-UPS CS Back-UPS CS 350

Liebert PowerSure PSI UPS

3000VA 120/208/230VAC

PR1000ELCD / PR1500ELCD User s Manual

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Uninterruptible Power Systems

Uninterruptible Power System

Uninterruptible Power System

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

charge it. then deploy it.

Uninterruptible Power Supply

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Back-UPS Intelligent, reliable protection for your home or small business Certainty in a Connected World

Uninterruptible Power System

Application. Battery. Public Grid GS HYBRID INVERTER

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

Solar Inverter 3kW-8kW Inverter (off-grid)

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

Eclipse Plus VA UPS and Surge Suppressor User s Manual

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Sola 3000 Guide Specifications

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

On-line, Single Phase, Double Conversion UPS

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

Uninterruptible Power Supply USER MANUAL Version 1.4. Always On UPS Systems Inc. GES-801L, GES-102L, GES-152L, GES-202L, GES-302L

HQST 500W (12V) HQST 1000W (12V) Modified Sine Wave Inverter. User Manual

Liebert PSA VA. Installer/User Guide

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Smart UPS On Line 120/208 V

Smart-UPS with APC SmartConnect Maintain business certainty with intelligent network power protection

BRAVER UPS. (Uninterruptible Power System) User s Manual

Smart-UPS: legendary uninterruptible power. Intelligent, reliable protection for servers and networks

Elite Pure Sine. DC To AC Power Inverters Convert 12V DC electricity into clean household-like power.

Liebert PSI XR 1000/1500/2200/3000, 120VAC. User Manual

Unity output power factor single-phase double-conversion, online UPS with advanced management features

Military and Security Applications

FN Series Scalable N+1 UPS 3kVA to 24kVA Rackmount

Transcription:

SmartPro Medical-Grade UPS, Line Interactive, Lithium Battery, 6 Outlets - 230V, 1kVA, 750W, Full Isolation MODEL NUMBER: SMX1200XLHGL Highlights Lithium battery backup allows time to save files and safely shut down during blackouts 6 C13 hospital-grade (HG) outlets provide power to medical equipment UL 60601-1 compliant for use in patient care vicinities when plugged into HG wall outlet Alarm and front-panel LEDs report online, battery, fault and overload conditions 10,000-cycle LiFePhos battery lasts up to 30x longer than comparable SLA batteries Line-interactive UPS provides basic battery backup with UL 60601-1 compliance for use in medical facilities, including patient care areas. Features 1kVA/750W Medical-Grade UPS Allows Time to Back Up Critical Files During a Blackout This 230V SmartPro hospital-grade UPS is fully compliant with UL 60601-1 regulations when plugged into a hospital-grade outlet, which makes it ideal for use in medical facilities, including patient care vicinities. It allows you to work through short power failures, and gives you enough time to safely save files and shut down your system in case of a prolonged blackout. Long-Lasting LiFePhos Battery Handles up to 10,000 Cycles with Ease This UPS system for hospitals contains a replaceable lithium iron phosphate (LiFePhos) internal battery that provides up to 30 times the cycle life of traditional sealed lead acid (SLA) batteries. The 6-outlet UPS system provides up to 28 minutes of battery backup at half load and 10 minutes at full load. During normal operation, incoming utility power keeps the replaceable internal battery fully charged, so backup power will always be available. Automatic Voltage Regulation (AVR) Corrects Potentially Hazardous Voltage Fluctuations AVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. This UPS for medical equipment can correct brownouts as low as 155V and overvoltages as high as 274V back to nominal 230V power without drawing on the battery backup needed to support your equipment during a blackout. Built-In Isolation Transformer Offers Full Isolation The isolation transformer with Faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes. Cumulative leakage current of all connected equipment is less than 100 microamps. Connect Your Equipment to 6 IEC 320 C13 Outlets Six C13 hospital-grade outlets provide both battery backup and surge protector for your mobile medical equipment, such as computers, monitors and lab equipment. A 340-joule surge suppression rating protects connected components from the harmful effects of power surges. Combats Electromagnetic Interference That Can Harm Equipment Various electromagnetic and radio sources found in virtually every home and business can cause Applications Protect your medical electronics against power surges, brownouts and blackouts in patient care vicinities Operate essential equipment during short-term power outages using battery backup power Shut down PCs, monitors, mobile medical components and other equipment without data loss during long-term power outages Package Includes SMX1200XLHGL 1kVA/750W SmartPro Medical-Grade UPS, Tower USB monitoring cable, 1.8 m (6 ft.) DB9 serial monitoring cable, 1.8 m (6 ft.) 1 / 5

disruptive interference on the AC line. Known as EMI (electromagnetic interference) and RFI (radio frequency interference), this line noise is a common cause of performance problems and can lead to incremental hardware damage, data corruption and audio/video transmission problems. This medicalgrade UPS system incorporates technology that filters out disruptive line noise so that it won t affect your equipment. Owner s manual Easy-to-Read LEDs and Alarm Report Real-Time UPS and Power Status Front-panel LED indicators monitor essential information, such as line power, battery power, overload, voltage regulation and battery low/replace status. An audible alarm will sound in case of low battery, excessive load and power failure. Saves Your Files, Even When You re Away USB and DB9 serial ports connect to your computer with the included cables. These ports communicate with Tripp Lite s free downloadable PowerAlert software for safe, unattended system shutdown and file saves in the event of a prolonged power failure. Tower Form Factor for Easy Placement on a Nurse s Station or Mobile Medical Cart The long-lasting PVC housing fits easily on a desktop, shelf or anywhere else power is needed. The 15- centimeter (six-inch) dongle with hospital-grade C14 plug connects to a properly grounded AC wall outlet. Specifications OVERVIEW UPC Code 037332224798 OUTPUT Output Volt Amp Capacity (VA) 1000 Output Watt Capacity (Watts) 750 Nominal Output Voltage(s) Supported Nominal Voltage Details Frequency Compatibility Frequency Compatibility Details Output Voltage Regulation (Line Mode) Output Receptacles Output AC Waveform (Battery Mode) Individually Controllable Load Banks 220V; 230V; 240V 230v nominal inverter output voltage 50 / 60 Hz Automatic frequency selection -18%, +8% (6) C13 PWM sine wave No INPUT Rated input current (Maximum Load) Nominal Input Voltage(s) Supported UPS Input Connection Type 5A 230V AC C14 inlet 2 / 5

UPS Input Cord Length (ft.) 0.50 UPS Input Cord Length (m) 0.2 Recommended Electrical Service 10A 230V Voltage Compatibility (VAC) 230 Input Phase Single-Phase BATTERY Full Load Runtime (min.) Half Load Runtime (min.) Expandable Battery Runtime External Battery Pack Compatibility 11 min. (750w) 27.5 min. (375w) Supports extended runtime with optional <a class="productlink" href="//www.tripplite.com/external-36v-2u- Rack-Tower-Battery-Pack-for-select-Tripp-Lite-UPS-Systems-BP36V15-2U~BP36V15-2U">BP36V15-2U</a> (limit 1) and <a class="productlink" href="//www.tripplite.com/external-36v-3u-rack-tower- Battery-Pack-select-Tripp-Lite-UPS-Systems-BP36V42-3U~BP36V42-3U">BP36V42-3U</a> external battery pack (multi-pack compatible) <a class="productlink" href="//www.tripplite.com/external-36v-2u-rack-tower-battery-pack-for-select-tripp- Lite-UPS-Systems-BP36V15-2U~BP36V15-2U">BP36V15-2U</a> (limit 1); <a class="productlink" href="//www.tripplite.com/external-36v-3u-rack-tower-battery-pack-select-tripp-lite-ups-systems-bp36v42-3u~bp36v42-3u">bp36v42-3u</a> (multi-pack compatible); <a class="productlink" href="//www.tripplite.com/external-36v-2u-rack-tower-battery-pack-select-tripp-lite-ups-systems~bp36v27-2us">bp36v27-2us</a> (multi-pack compatible) DC System Voltage (VDC) 36 Battery Recharge Rate (Included Batteries) Internal UPS Replacement Battery Cartridge Battery Access Typical Battery Lifespan Expandable Runtime Less than 4.5 hours from 10% to 90% RBC53L Battery access door allows hot swap battery replacement without powering connected equipment off 3-6 years, depending on usage Yes VOLTAGE REGULATION Voltage Regulation Description Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 155 to 274V AC. Overvoltage Correction Input voltages between 245 and 274V AC are reduced by 9% Undervoltage Correction Input voltages between 183 and 199 are boosted by 10% Severe Undervoltage Correction Input voltages between 156 and 182 are boosted by 21% USER INTERFACE, ALERTS & CONTROLS Switches Audible Alarm LED Indicators Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions Audible Alarm is factory muted for silent operation; Audible alarm can be restored to indicate power failure, overload conditions and Low Battery events using our Free Power Alert UPS management software. 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status SURGE / NOISE SUPPRESSION 3 / 5

UPS AC Suppression Joule Rating 340 EMI / RFI AC Noise Suppression AC Suppression Response Time Yes Instantaneous PHYSICAL Installation Form Factors Supported with Optional Accessories Primary Form Factor UPS Power Module Dimensions (hwd, in.) Wallmount (UPSWM - tower mounting kit) Tower 12.7 x 7.5 x 9.1 UPS Power Module Weight (lbs.) 45.5 UPS Power Module Weight (kg) 20.64 Shipping Dimensions (hwd / in.) 18.50 x 12.20 x 13.38 Shipping Weight (kg) 22.14 Cooling Method UPS Housing Material UPS cooling via rear-exit fan PVC Primary UPS Height (mm) 323 Primary UPS Width (mm) 191 Primary UPS Depth (mm) 231 ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius 0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 252.2 Battery Mode BTU / Hr. (Full Load) 252.2 COMMUNICATIONS Communications Interface USB; DB9 Serial LINE / BATTERY TRANSFER Transfer Time Low Voltage Transfer to Battery Power (Setpoint) High Voltage Transfer to Battery Power (Setpoint) 2-4 milliseconds 155 274 SPECIAL FEATURES Grounding Lug Ground Potential Equalization Connector: POAG-S6/20 4 / 5

Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported CERTIFICATIONS UPS Certifications CE; Tested to UL60601-1 (medical grade) WARRANTY Product Warranty Period (International) Product Warranty Period (Mexico) Product Warranty Period (Puerto Rico) 2018 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies: https://www.tripplite.com/products/product-certification-agencies 5 / 5