@Perkins. Technical Data

Similar documents
@Perkins. Technical Data. 192, rev/min. ElectropaK

@Perkins. Technical Data. 1106D-E66TAG3 159, rev/min. 1100D Series. ElectropaK

1106A-70TAG3. Series kwm 1500rpm ElectropaK. Basic technical data

1106A-70TAG4. Series kwm 1500rpm ElectropaK. Basic technical data

1106A-70TAG4. Series kwm 1500 rpm ElectropaK. Basic technical data. General installation

Technical Data TWG2A TWG3A Series. Diesel Engine - ElectropaK rev/min. Basic technical data

@Perkins. Technical Data Series 1104C-44TAG2. Diesel Engine ElectropaK. 99, rev/min 112, rev/min Performance

1106A-70TAG2. Series kwm 1800rpm ElectropaK. Basic technical data

@Perkins. Technical Data Series 1104C-44TAG1. Diesel Engine ElectropaK. 79, rev/min 88, rev/min. Basic technical data

Performance. Perkins Engines Company Limited. Perkins Engines Company Limited. Peterborough PE1 5FQ United Kingdom Tel: +44 (0)

Technical Data. 400 Series 403D-15G. ElectropaK

Technical Data Series 1103D-33 G3. Diesel engine - Electropak rpm

@Perkins. Technical Data. 400 Series 403D-11G. ElectropaK

@Perkins. Technical Data Series 1103C-33TG3. Performance. Basic technical data. Test conditions. Total weight (fan to flywheel)) Sound level

Technical Data 4008TAG 4008TAG1 4008TAG Series. Diesel Engine - ElectropaK

1106A-70TG1. Series kwm 1500rpm ElectropaK. Basic technical data

Technical Data. 400 Series 403D-11G. ElectropaK

@Perkins. Technical Data Series 2806A-E18TAG1A. Basic technical data. Cyclic irregularity for engine/flywheel maximum: Ratings.

@Perkins. Technical Data Series TAG1A TAG2A TAG3A. Diesel Engine - Electropak. Basic technical data

Technical Data. ElectropaK

@Perkins. Technical Data Series 1104C-44TG1. Diesel Engine ElectropaK. 66, rev/min. Basic technical data.

@Perkins. Technical Data Series 2806C-E18TAG1A. Diesel Engine - ElectropaK. Basic technical data. Cyclic irregularity. Ratings.

1104D-44TG2 1104D-44TG kwm 1500/1800 rpm. ElectropaK. Series. Basic technical data. Performance

TAG3. Diesel engine - ElectropaK. Series kwm 1500 rpm. Basic technical data. Ratings. Total weight of ElectropaK

Technical Data 2506A-E15TAG3 2506A-E15TAG Series. Diesel Engine - ElectropaK

50Hz 1500 rev/min 1 / 2 TA Luft* Prime Power. Standby Max

Technical Data 2506C-E15TAG3 2506C-E15TAG Series. Diesel Engine - ElectropaK

@Perkins. Technical Data Series 2806C-E18TAG3. Diesel Engine - ElectropaK. Cyclic irregularity. Basic technical data. Ratings.

Continuous Baseload. Prime Power

Technical Data 1300 Series EDi 1306C-E87TAG4

Technical Data Series 2506D-E15TAG2. Diesel Engine - ElectropaK. Basic technical data

1506A-E88TAG5. Series. 293 kwm 1500 rpm 333 kwm 1800 rpm. Basic technical data

4016TAG1A 4016TAG2A. Series kwm 1500 rpm kwm 1500 rpm ElectropaK. Ratings. Basic technical data

@Perkins. Technical Data Series 1104C-44G2. 52, rev/min. Electropak. Basic technical data. Performance

1606A-E93TAG4. Series kwm 1800 rpm ElectropaK. Basic technical data. Performance. Test conditions. Notes:

@Perkins. Technical Data Series 1104A-44TG2. 79, rev/min 90, rev/min. Gen Set. Basic technical data.

TAG2A TAG3A. Series kwm 1500/1800 rpm kwm 1500/1800 rpm ElectropaK. Ratings. Basic technical data

Technical Data TRG TRG TRG Series

@Perkins. Technical Data Series 1103A-33TG1. 45, rev/min 53, rev/min. Gen Set. Basic technical data.

1103A-33TG1. Series. Genset rpm rpm. Performance. Basic technical data

Technical Data Series 1206E-E70TTA. Basic technical data. Performance

1103A-33TG2. Series. Genset rpm rpm. Performance. Basic technical data

Technical Data 404D-22

400 Series 403D-11G ElectropaK rpm

Technical Data Series 1204E-E44TA. Basic technical data. Performance

Ratings TAG2A (1500 rpm)...1: TAG2A (1800 rpm)...1: TAG3A (1500 rpm)...1: TAG3A (1800 rpm)...

Technical Data Series TWG4A. Basic technical data. Cyclic irregularity For engine/flywheel maximum... 1:752

1106C-70TA. Series. Industrial Open Power Unit. Tier rpm. Basic technical data. Ratings

Technical Data Series 1206E-E70TTA. Industrial Open Power Unit (IOPU) Performance. Basic technical data

4008 TAG1A 4008 TAG2A. Series kwm 1500 rpm kwm 1500 rpm ElectropaK. Basic technical data.

Technical Data Series 1206E-E70TTA. Basic technical data. Performance

Technical Data Series TWG2A TWG3A. Basic technical data

TAG1A TAG2A. Series kwm 1500 rpm kwm 1500 rpm ElectropaK. Basic technical data.

Technical Data TWG2A TWG3A Series. Diesel Engine - ElectropaK rev/min. Basic technical data

TRG TRG TRG3

Technical Data TRS TRS Series. Gas Engine rev/min

@Perkins. Technical Data Series 2806A-E18TAG1A. Basic technical data. Cyclic irregularity for engine/flywheel maximum: Ratings.

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

2200 Series 2206A-E13TAG2 Diesel Engine - ElectropaK

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

1000 Series 1004G Diesel Engine ElectropaK Belt-Driven Coolant Pump

PERKINS SERIE E14 PNY350 PNY400 PNY350 PNY400 HCI434F HCI434E. Dimensiones (Largo x Ancho x Alto)cm Peso Aprox. humedo kg.

2000 Series 2206C-E13TAG2 Diesel Engine ElectropaK rpm

PERKINS SERIE E18TAG PNY600. Dimensiones (Largo x Ancho x Alto)cm Peso Aprox. humedo kg. 350x153x HCI534E. 145 x :1 /Enfriado por aire

Image shown may not reflect actual engine configuration.

400 Series 404A-22G1 ElectropaK 20.3 kwm / rpm

PERKINS SERIE E15TAG PNY500 PNY500. Dimensiones (Largo x Ancho x Alto)cm Peso Aprox. humedo kg. HCI534D. 135 x /Enfriado por aire

1100 Series 1104D-E44TG1 Diesel Engine ElectropaK 71.8 kwm (96 hp) net standby 1800 rpm

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

Engine Performance 1500 RPM

400 Series 404D-22G ElectropaK rpm

1100 Series 1104C-44TAG1 Diesel Engine ElectropaK rpm

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour

SIDE VIEW FRONT VIEW

8,000 Watt Diesel Generator

400 Series 403A-15G1 ElectropaK 13.2 kwm / rpm

400 Series 403D-15G ElectropaK rpm

400 Series 403D-11G ElectropaK rpm

NORTHSTAR. Power Systems NSPS 100 ENGINE KEY FEATURE GENERATOR CONTROLS STANDBY RATING: ALTERNATOR TYPE:

10,000 Watt Diesel Generator AGi9P E

1100 Series 1104A-44TG1 Diesel Engine ElectropaK 75.5 kwm / rpm

1500 Series 1506A-E88TAG4 ElectropaK 267 kwm standby net 1500 rpm

1100 Series 1104D-44TG3 Diesel Engine ElectropaK 54 kwm (72 hp) net prime 1500 rpm 59 kwm (79 hp) net standby 1500 rpm

400 Series 402D-05G Electro Unit rpm

2800 Series 2806C-E18TAG1A Diesel Engine ElectropaK 598 kwm at 1800 rpm

2200 Series 2206A-E13TAG3 Diesel Engine ElectropaK rpm

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

MODEL PERFORMANCE. ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... lb ft (N m) 1000 (1356)

400 Series 403D-07G Electro Unit rpm

Triton 80kW. Standy Rating: Triton 80kW. Triton Power Corp 8511 NW 61st Street Miami, FL T: F:

1100 Series 1103A-33TG2 Diesel Engine ElectropaK 67.5 kwm / rpm

2500 Series 2506A-E15TAG3 Diesel Engine ElectropaK Non-Emissions compliant 490 kwm at 1800 rpm

13,000 Watt Diesel Generator AGi13P E

2800 Series 2806A-E18TAG2 Diesel Engine ElectropaK 609 kwm at 1500 rpm

Transcription:

Technical Data 1100C Series ElectropaK Basic technical data Number of cylinders..................................................... 6 Cylinder arrangement............................................. in-line Cycle..............................................................4 stroke Induction system............... turbocharged and air charge cooled Combustion system............................. direct injection diesel Compression ratio................................................. 16,2:1 Bore.............................................................. 105 mm Stroke............................................................ 127 mm Cubic capacity.................................................. 6,6 litres Direction of rotation...... anti-clockwise when viewed from flywheel Firing order (number 1 cylinder furthest from flywheel) 1 5 3 6 2 4 Estimated total weight of Electropak (dry).....................788 kg Estimated total weight of Electropak (wet).....................822 kg Overall dimensions - Electropak -height......................................................... 1140.4 mm -length (air cleaner fitted)................................... 1763.2 mm -width......................................................... 788.3 mm Moments of rotational inertia (mk²) Engine rotational components............................. 0.27 kgm² Flywheel...................................................... 1.31 kgm² Centre of gravity - Electropak (wet) Forward of rear face of cylinder block...................... 476,3 mm Above crankshaft centre line................................ 176,4mm Offset to RHS of crankshaft centre line....................... 16 mm @Perkins 1106C-E66TAG4 175.9 kwm @ 1500 rev/min 197.3 kwm @ 1800 rev/min Performance Note: All data based on operation to ISO 14396 standard reference conditions. All ratings certified to within...................................... + 3% Speed variation at constant load............................. + 0,25% Cyclic irregularity at 110% stand-by power -1500 rev/min.......................................................0.028-1800 rev/min...................................................... 0.020 Test conditions -air temperature.................................................... 25 C -barometric pressure............................................ 100 kpa -relative humidity.................................................. 31.5% -air inlet restriction at maximum power (nominal).............. 5 kpa -exhaust back pressure at maximum power (nominal)...... 15 kpa -fuel temperature (inlet pump).................................... 40 C Sound level Average sound pressure level for ElectropaK at 1 metre -@ 1500 rev/min........................................... 111,6 db(a) -@ 1800 rev/min........................................... 113,0 db(a) If the engine is to operate in ambient conditions other than those of the test conditions, suitable adjustments must be made for these changes. For full details, contact Perkins Technical Service Department. Certified against the requirements of EU2007 legislation for nonroad mobile machinery, powered by constant speed engines (EU97/68/EC Stage II) General installation Designation Units Prime Standby Prime Standby 50Hz 60Hz Brake mean effective pressure kpa 1981,0 2189,0 1877,0 2065,0 Engine coolant flow (against 35 kpa restriction) l/min 180,0 216,0 Combustion air flow (at STP) m³/min 11,3 11,7 13,3 13,4 Exhaust gas flow (Max.) m³/min 29,4 31,0 33,4 34,8 Max. exhaust gas temperature in manifold after turbocharger C 480 499 485 509 Overall thermal efficiency (nett) % 39,3 39,8 38,1 38,8 Typical genset electrical output (0.8pf 25 C) kwe 144,0 160,0 160,0 175,0 kva 180 200 200 219 Regenerative power (estimated) kw 8,8 14,9 Assumed alternator efficiency % 91,9 92,3 92,1 91,0 Energy balance Energy in fuel kwt 403,8 442,3 467,5 508,0 Energy in power output (gross) kwb 163,3 180,4 185,3 204,3 Energy to cooling fan kwm 4,5 7,0 Energy in power output (net) kwt 158,8 175,9 178,3 197,3 Energy to exhaust kwt 125,0 135,7 148,3 160,4 Energy to coolant and oil kwt 72,8 79,8 82,2 89,5 Energy to radiation kwt 12,5 13,7 14,5 15,7 Energy to charge cooler kwt 30,2 32,7 37,2 38,1

1106C-E66TAG4 - Left side view

1106C-E66TAG4 - Front view

1106C-E66TAG4 - Right side view

1106C-E66TAG4 - Rear view

1106C-E66TAG4 - Plan view

Cooling system Recommended coolant: 50% inhibited ethylene glycol or 50% inhibited propylene glycol and 50% clean fresh water. Where there is no likelihood of ambient temperature below 10 C, then clean soft water may be used, treated with 1% by volume of Perkins inhibitor. Cooling pack -overall weight (wet).............................................. 71 kg -overall face area........................................... 0.55476 m² -width............................................................ 745 mm -height.......................................................... 1080 mm Radiator Face area..................................................... 0.3512 m² Number of rows and materials................... 5 rows, aluminium Matrix density and material............. 10 fins per inch, aluminium Width of matrix................................................. 439 mm Height of matrix................................................ 800 mm Pressure cap setting (min).................................... 100 kpa Charge cooler Face area.................................................... 0.20356 m² Number of rows and materials................... 2 rows, aluminium Matrix density and material............. 10 fins per inch, aluminium Width of matrix................................................. 258 mm Height of matrix................................................ 789 mm Fan Diameter......................................................... 686 mm Drive ratio............................................................ 1.2:1 Number of blades....................................................... 7 Material..............................................................nylon Type............................................................... pusher Air flow -1500 rev/min............................................. 280.8 m³/min -1800 rev/min............................................. 313.8 m³/min Coolant Total system capacity.......................................... 21 litres System drawdown capacity........................................ 10% Engine capacity................................................ 9.5 litres Maximum top tank temperature................................ 112 C Temperature rise across engine Max. rating dependent.................................. 6.8 to 11.0 C Max. permissible external system resistance................. 35 kpa Thermostat operation range................................ 85 to 95 C Shutdown switch setting........................................ 118 C Coolant pump method of drive.................................. gears Recommended coolant immersion heater rating (minimum)................................................ 0.75 kw Recommended coolant.........................................................bs6580-1992, ASTM D3306 and ELC coolants to 1E1966 Duct Allowance 1106C-E66TAG3 - Maximum additional restriction (Duct allowance to cooling airflow and resultant min. airflow (Standby power) Duct allowance with inhibited coolant at 53 C Description rev/min kpa m³/min 1500 0,125 281 Duct allowance 1800 0,125 314 Duct allowance with inhibited coolant at 43 C 1500 0,200 281 Minimum airflow 1800 0,200 314 Electrical system Alternator................................................... Denso A127i Alternator voltage............................................... 12 volts Alternator output............................................. 100 amps Starter................................................................38MT Starter motor voltage.......................................... 12 volts Starter motor power............................................. 5.0 kw Number of teeth on the flywheel.................................. 134 Pull-in current of starter motor solenoid @ -25 C Max........................................... pulse signal 12 volts (5 amps) Hold-in current of starter motor solenoid @ -25 C Max........................................... pulse signal 12 volts (5 amps) Engine stop method.......................................... via ECM Note: All leads rated at 10 amps minimum. Cold start recommendations Minimum required cranking speed over TDC............. 60 rev/min 5 to -10 C -10 to -20 C -20 to -25 C Oil 15W40 10W40 5W40 Battery 2 x 900CCA Max. breakaway current 1012 amps Cranking current 500 (760 Max.) amps Aids Glowplugs Minimum mean cranking speed 92 rev/min 103 rev/min 107 rev/min Notes: Battery capacity is defined by the 20 hour rate If a change to a low viscosity oil is made, the cranking torque necessary at low ambient temperatures is much reduced. The starting equipment has been selected to take advantage of this. It is important to change to the appropriate multigrade oil in anticipation of operating in low ambient temperatures Breakaway current is dependent on battery capacity available. Cables should be capable of handling the transient current which may be up to double the steady cranking current. Induction system Maximum air intake restriction -clean filter...........................................................5 kpa -dirty filter............................................................8 kpa -air filter type............................................. paper element Exhaust system Maximum back pressure -1500 rev/min...................................................10.0 kpa -1800 rev/min..................................................15.0 kpa Exhaust outlet, internal diameter.............................. 90 mm

1100C Series Fuel system Injection components Injector..........................................................electronic Fuel pump......................................................... CR200 Fuel priming Priming pump type................................. manual / electronic Maximum priming time......................................90 seconds Fuel feed Maximum fuel flow..............................................1.5 l/min Maximum suction head at engine fuel pump inlet............30 kpa Maximum static pressure head................................ 600 kpa Fuel temperature at engine fuel pump inlet..................... 80 C Tolerance on fuel consumption...................................... 3% Fuel specification Fuel standard - BS2869, 1998 Class A2 or BS EN590 Fuel consumption Type of operation and application Load 1500 rev/min g/kwhr Note: Based on gross rated power Lubrication system 1800 rev/min g/kwhr 1500 rev/min l/hr 1800 rev/min l/hr Standby 204,9 207,5 44,0 50,5 110% prime 205,1 208.0 43,8 50,4 Prime 206,9 211,1 40,2 41,3 75% prime 212,7 222,7 31,0 36,8 50% prime 211,6 231,6 20,5 25,5 Maximum total system oil capacity.........................16.5 litres Minimum oil capacity in sump...............................12.5 litres Maximum oil capacity in sump...............................15.5 litres Maximum engine operating angles - front up, front down, right side, left side.......................... 25 Sump drain plug tapping size............................ 3/4-16 UNF Shutdown switch setting (where fitted).............. ECM controlled 1106C-E66TAG4 Lubricating oil -relief valve opening pressure.................................430 kpa -pressure at maximum speed..................................450 kpa -maximum continuous oil temperature (in rail)............... 125 C -oil consumption at full load (% of fuel).......................... < 0.1 Recommended SAE viscosity 15W-40 10W-40 10W-30 5W-40 5W-30 0W-40 0W-30 0W-20 Viscostiy grade -50-40 -30-20 -10 0 10 20 30 40 50 60 Ambient Temperature Deg C A multigrade oil must be used which conforms to API-CH4/CI4. Mountings Maximum static bending moment at -rear face of block............................................. 1130 Nm Maximum permissible overhung load -on the flywheel................................................. TBA Nm Maximum bending moment at rear -of flywheel housing in shock............................. +/-4200 Nm Load acceptance Load acceptance............................ full data avaialble mid 07 All tests were conducted using an engine installed and serviced to Perkins Engine company limited recommendations. Applied load is a percentage of generator electrical output efficiencies as published in the general installation of this data sheet. The information given on this technical data sheet is for standards ratings only and is for guidance only. For ratings other than those shown, contact Perkins Engines Limited, Peterborough. @Perkins Perkins Engines Company Limited Peterborough PE1 5NA United Kingdom Telephone +44 (0) 1733 583000 Fax +44 (0) 1733 582240 www.perkins.com All information in the document is substantially correct at the time of printing but may be subsequently altered by the company. Distributed by Publication No. TPD1620E, Issue 1. March 2007. Perkins Engines Company Limited.