DP13CM. Packaged Air Conditioner 3, 4, & 5 Tons / 13 SEER. Cooling Capacity: 36,000-56,000 BTU/h

Similar documents
GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h

GPC13M COMMERCIAL PRODUCT SPECIFICATIONS 13 SEER PACKAGED AIR CONDITIONER 3- TO 5-TON COOLING CAPACITY 35,000-56,000 BTU/H

DP14HM Commercial 3-5 TON THREE-PHASE PACKAGED HEAT PUMPS 14 SEER. Cooling Capacity: 34,400-58,000 BTU/h Heating Capacity: 33,200-57,000 BTU/h

GPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h

GPH13M. 13 SEER / R-410A 2 to 5 Tons

DP14GM. Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons. Cooling Capacity: 23,000 57,500 BTU/h Heating Capacity: 40, ,000 BTU/h

DZ11S Commercial & 10-Ton, Three-Phase

DZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A

DTC Commercial. 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER. Cooling Capacity: 35,600 60,000 BTU/h

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h

DX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase. Cooling Capacity: 36,000-60,000 BTU/h

DX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase Split System Air Conditioner. Cooling Capacity: 36,000-60,000 BTU/h

High-quality UV-resistant powder-paint finish aluminized steel tubular heat exchanger

GSX SEER / 1½ to 5 Tons. Split System Air Conditioner. 18,000-60,000 BTU/h

DCH Commercial Contents Standard Features Cabinet Features

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE

DZ11S Commercial. Plus & 10-Ton, Three-Phase Split System Heat Pump with One Two-Speed Indoor Air Handler and Two 4-Ton or Two 5-Ton Condensers

DX11S Commercial & 10-ton, Three-Phase Split System Air Conditioner 11.2 EER / R-410A. Plus

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11.

Packaged Gas/Electric. Cooling Capacity: 23,000 57,500 BTU/h

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

DX18TC. High-Efficiency, ComfortNet -Compatible, Split System Air Conditioner Up to 19 SEER. Cooling Capacity: 34,600-58,000 BTU/h

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h

Split System. GSC13: 3-5 Tons GSC10: 7½ & 10 Tons. Air Conditioner

DSXC18. Split System Air Conditioner. 34,000-56,000 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

GSZ16. High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons

SSX16 PRODUCT SPECIFICATIONS 16 SEER / R-410A 2 TO 5 TONS HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY 24,000 BTU/H TO 57,000 BTU/H

DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient

DCC Commercial. 15- & 20-Ton, Three-Phase. 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h. Packaged Air Conditioners

ASXC18. High-Efficiency, ComfortNet -Compatible, Split-System Air Conditioner Up to 19 SEER. Cooling Capacity: 24,000-60,000 BTU/h

CPH Commercial. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. Cooling / Heating Capacities: up to 11.5 EER up to 3.5 COP. 90, ,000 BTU/h

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H

APD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h

GPG COMMERCIAL PRODUCT SPECIFICATIONS 13 & 10 SEER 80% AFUE 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

GSC13 Split System Air Conditioner

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h

2- to 5-Ton. Cooling Capacities: 23,600 to 57,000 BTU/h. Packaged Gas/Electric Units. Heating Capacities: 46,000 to 138,000 BTU/h

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E.

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON

DTG Commercial. 3-5 Tons Gas/ Electric Units Up to 15.5 SEER and 13.0 EER Up to 81% AFUE

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E.

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h

3- to 6-Ton. 13 SEER / up to 11.3 EER & 7.7 HSPF. Packaged Heat Pump. Heating Capacity: 34,600 70,000 BTU/h. Cooling Capacity: 35,000 70,000 BTU/h

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

DP14GM Commercial 14 SEER / 81% AFUE 3-5 TON, THREE-PHASE PACKAGED GAS/ELECTRIC. Cooling Capacities: 34,200 to 57,000 BTU/h

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h

Multi-Position Air Handler. 1½ to 5 Tons. with Energy-Saving Motor

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

DCG Commercial. 7½- to 10-Ton Three-Phase Packaged Gas/ Electric. Cooling Capacity: 88, ,000 BTU/h Heating Capacity (Output): 144,000 BTU/h

AVXC20. High-Efficiency, Comfortnet-Compatible, Variable-Speed, Inverter Drive Split System Air Conditioner. Cooling Capacity : 23,600 53,000 BTU/h

GPH 13 H SERIES HORIZONTAL Package Heat Pump Units with R-410A

ARUF Series Multi-Position

TECHNICAL MANUAL. *PC 14 SEER R-410A Package Air Conditioners with R-410A

CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

ARUF. Multi-Position Air Handler. 1½ to 5 Tons. Construction

GPC 14 SEER R-410A Package Air Conditioners with R-410A

ARPT. Multi-Position 1½ to 5 Tons Construction

CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

DCC Commercial Tons Packaged Air Conditioners

GPG13 SINGLE-PHASE, SELF-CONTAINED

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

ARUF PRODUCT SPECIFICATIONS AIR HANDLER 1½ TO 5 TONS MULTI-POSITION, THREE-SPEED WITH GALVANIZED CABINET

ARUF. 1½ to 5 Tons. O when tested in accordance with ASHRAE standard 193 Cabinet air leakage less than 1.4% at 0.5 inch H 2

CPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS

SSZ 14 SEER Split System Heat Pumps

AWUF Series. Wall-Mount Air Handler 1½- to 3-Tons

ASPF. Product Specifications. Multi-Position Air Handler. 1½ to 5 Tons. with Energy-Saving Motor

PHR5. Product Specifications

AWUF, AWUT Series. Wall-Mount Air Handler 1½ to 3 Tons. Contents. Product Features

Cabinet Features. upflow, horizontal left or right matically adjusts to high or low stage

n Heavy-duty, high efficiency compressor n Copper tubing with enhanced fin coils n External service gauge ports CABINET

TECHNICAL INFORMATION MANUAL

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

TECHNICAL MANUAL. *SZC 16 SEER Split System Heat Pumps

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

HCH6. Product Specifications

ASPT Multi-Position Air Handler

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

DCC Commercial. 6 Ton Packaged Air Conditioner Up to 11.3 EER

GSZ/VSZ 13 SEER Split System Heat Pumps

ARPF. Air Handler with Painted Cabinet. 1½ to 5 Tons Multi-Position,

PCB COMMERCIAL SERIES

Transcription:

DP13M ooling apacity: 36,000-56,000 BTU/h Packaged Air onditioner 3, 4, & 5 Tons / 13 SEER ontents Nomenclature... Product Specifications... 3 Expanded ooling Data... 4 Airflow Data... 10 Heat Kit Electrical Data... 11 Dimensions... 13 Wiring Diagrams... 14 Accessories... 16 Standard Features Energy-efficient compressor with internal relief valve EEM blower motor; PS blower motor on 3-ton units onvertible airflow: horizontal or downflow All-Aluminum evaporator coil opper tube / aluminum fin condenser coil Totally enclosed, permanently lubricated condenser fan motor Fully charged R-410A system Electric heat kit available as a field-installed accessory AHRI ertified; ETL Listed abinet Features Heavy-gauge galvanized-steel cabinet with attractive Nickel Gray powder-paint finish Fully insulated blower compartment with convenient access panels Louvered condenser coil protection One footprint; two heights * omplete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 1-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in alifornia or Quebec. SS-DP13M www.daikincomfort.com 11/13 Supersedes 9/13

Nomenclature D P 13 M 36 4 1 A * 1 3,4 5 6 7,8 9 10 11 1 Brand D - Daikin Product Type P - Packaged Engineering Minor revision Engineering Major revision SEER Voltage 13-13 SEER 1-08/30V, 1- phase, 60 Hz 14 - Up to 14 SEER 3-08/30V, 3- phase, 60 Hz 15 - Up to 15 SEER Refrigerant Unit Type 4 - R- 410A H - Heat Pump - Air ondikoner Tonnage Nominal 4 - Tons 4-3½ Tons onfiguralon 30 - ½ Tons 48-4 Tons M - MulK- posikon 36-3 Tons 60-5 Tons H - Horizontal www.daikincomfort.com SS-DP13M

Specifications ooling apacity DP13M 3641A* DP13M 4841A* DP13M 6041A* Total BTU/h 35,000 45,500 56,000 Sensible BTU/h 5,550 36,855 4,560 SEER / EER 13 / 11.0 13 / 11 13 / 10.9 Decibels 80.1 81.7 80. AHRI Numbers 667934 6679343 6679344 Evaporator Motor Type DD EEM EEM Nominal ooling FM 1,080 1,675 1,750 Wheel (DxW) 10 x 9 10 x 9 10 x 9 No. of Speeds 3 5 5 Horsepower - RPM ⅓ ¾ 1.0 Evaporator oil Face Area (ft²) 4.55 6.0 6.0 Rows Deep/ Fin per Inch 4/ 14 4/ 14 4/ 14 Drain Size (NPT) ¾" ¾" ¾" Refrigerant harge (oz.) 70 116 195 ondenser Fan / oil Horsepower - RPM ¼ - 1,075 ¼ - 1,075 ¼ - 1,075 Fan Diameter / # Fan Blades / 3 / 3 / 3 Face Area (ft²) 8.77 15.36 1.04 Rows Deep/ Fins per Inch / 7 1/ 4 / 16 ompressor Quantity 1 1 1 Type Scroll Scroll Scroll Stage Single Single Single Electrical Data Voltage-Phase 08/30-1 08/30-1 08/30-1 ompressor RLA/LRA 16.7 / 79 19.9 / 109 6.4 / 134 Indoor Blower FLA / LRA 3.06 / 4.1 5.8 / - 7.6 / - Outdoor Fan FLA / LRA 1.4 /.9 1.4 /.9 1.4 /.9 Total Unit Amps 1. 7.1 35.4 Min. ircuit Ampacity¹ 5.3 3.1 4 Max. Overcurrent Protection² 40 amps 50 amps 60 amps Ship Weight (lbs) 365 435 458 ¹ Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HAR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-DP13M www.daikincomfort.com 3

Expanded ooling Data DP13M3641A* Outdoor Ambient Temperature 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 135 1180 965 MBh 33.3 34.5 37.8-3.5 33.7 36.9-31.7 3.9 36.1-31.0 3.1 35. - 9.4 30.5 33.4-7.3 8.3 31.0 - S/T 0.70 0.59 0.41-0.73 0.61 0.4-0.75 0.6 0.43-0.77 0.64 0.45-0.80 0.67 0.46-0.81 0.67 0.47 - T 17 15 11-18 15 1-18 15 1-18 15 1-18 15 1-16 14 11 - kw.48.53.61 -.66.71.80 -.8.88.97 -.96 3.0 3.11-3.08 3.14 3.4-3.18 3.5 3.35 - Amps 10.6 10.9 11.1-11.3 11.6 11.9-1. 1.4 1.7-1.9 13.1 13.5-13.6 13.8 14. - 14. 14.5 15.0 - HI PR 36 54 68-65 85 301-301 34 34-343 369 390-386 415 438-46 459 484 - LO PR 107 114 15-114 11 13-118 16 137-14 13 144-130 138 151-134 143 156 - MBh 33.3 34.5 37.8-3.5 33.7 36.9-31.7 3.9 36.1-31.0 3.1 35. - 9.4 30.5 33.4-7.3 8.3 31.0 - S/T 0.70 0.59 0.41-0.73 0.61 0.4-0.75 0.6 0.43-0.77 0.64 0.45-0.80 0.67 0.46-0.81 0.67 0.47 - T 18 16 1-18 16 1-18 16 1-19 16 1-18 16 1-17 15 11 - kw.48.53.61 -.66.71.80 -.8.88.97 -.96 3.0 3.11-3.08 3.14 3.4-3.18 3.5 3.35 - Amps 10.6 10.9 11.1-11.3 11.6 11.9-1. 1.4 1.7-1.9 13.1 13.5-13.6 13.8 14. - 14. 14.5 15.0 - HI PR 36 54 68-65 85 301-301 34 34-343 369 390-386 415 438-46 459 484 - LO PR 107 114 15-114 11 13-118 16 137-14 13 144-130 138 151-134 143 156 - MBh 30.7 31.9 34.9-30.0 31.1 34.1-9.3 30.4 33.3-8.6 9.6 3.5-7. 8. 30.8-5. 6.1 8.6 - S/T 0.68 0.57 0.39-0.70 0.59 0.41-0.7 0.60 0.4-0.74 0.6 0.43-0.77 0.64 0.45-0.78 0.65 0.45 - T 0 17 13-0 17 13-0 17 13-0 18 13-0 17 13-19 16 1 - kw.43.47.55 -.60.65.73 -.75.81.90 -.89.95 3.04-3.00 3.07 3.16-3.10 3.17 3.7 - Amps 10.4 10.6 10.9-11.1 11.3 11.6-11.9 1.1 1.5-1.6 1.8 13. - 13. 13.5 13.9-13.9 14. 14.6 - HI PR 9 46 60-57 76 9-9 314 33-333 358 378-374 403 45-413 445 470 - LO PR 104 111 11-110 117 18-114 1 133-10 18 140-16 134 146-130 139 151-75 135 1180 965 MBh 33.9 34.9 37.7 40.5 33.1 34.1 36.9 39.6 3.3 33. 36.0 38.6 31.5 3.4 35.1 37.7 9.9 30.8 33.3 35.8 7.7 8.5 30.9 33. S/T 0.80 0.71 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.91 0.81 0.6 0.40 0.9 0.8 0.6 0.40 T 0 19 15 10 0 19 15 11 0 19 15 11 1 19 15 11 0 19 15 11 19 17 14 10 kw.50.55.63.71.68.74.8.91.84.90.99 3.08.98 3.04 3.14 3.4 3.10 3.17 3.7 3.37 3.0 3.7 3.38 3.49 Amps 10.7 10.9 11. 11.6 11.4 11.7 1.0 1.4 1. 1.5 1.8 13.3 13.0 13. 13.6 14.0 13.7 13.9 14.3 14.8 14.4 14.7 15.1 15.6 HI PR 38 57 71 83 67 88 304 317 304 37 346 361 346 373 394 411 390 419 443 46 431 463 489 510 LO PR 109 115 16 134 115 1 133 14 119 17 138 147 15 133 145 155 131 140 15 16 136 144 158 168 MBh 33.9 34.9 37.7 40.5 33.1 34.1 36.9 39.6 3.3 33. 36.0 38.6 31.5 3.4 35.1 37.7 9.9 30.8 33.3 35.8 7.7 8.5 30.9 33. S/T 0.80 0.71 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.91 0.81 0.6 0.40 0.9 0.8 0.6 0.40 T 1 19 16 11 1 0 16 11 1 0 16 11 1 0 16 11 1 0 16 11 0 18 15 10 kw.50.55.63.71.68.74.8.91.84.90.99 3.08.98 3.04 3.14 3.4 3.10 3.17 3.7 3.37 3.0 3.7 3.38 3.49 Amps 10.7 10.9 11. 11.6 11.4 11.7 1.0 1.4 1. 1.5 1.8 13.3 13.0 13. 13.6 14.0 13.7 13.9 14.3 14.8 14.4 14.7 15.1 15.6 HI PR 38 57 71 83 67 88 304 317 304 37 346 361 346 373 394 411 390 419 443 46 431 463 489 510 LO PR 109 115 16 134 115 1 133 14 119 17 138 147 15 133 145 155 131 140 15 16 136 144 158 168 MBh 31.3 3. 34.8 37.4 30.5 31.4 34.0 36.5 9.8 30.7 33. 35.6 9.1 9.9 3.4 34.8 7.6 8.4 30.8 33.0 5.6 6.3 8.5 30.6 S/T 0.77 0.69 0.5 0.34 0.80 0.71 0.54 0.35 0.8 0.73 0.55 0.36 0.84 0.75 0.57 0.37 0.88 0.78 0.59 0.38 0.88 0.79 0.60 0.38 T 3 1 17 1 3 1 17 1 3 1 18 1 3 18 1 3 1 17 1 0 16 11 kw.44.49.57.64.6.67.75.84.77.83.9 3.01.91.97 3.06 3.16 3.03 3.09 3.19 3.9 3.13 3.19 3.30 3.40 Amps 10.5 10.7 11.0 11.3 11. 11.4 11.7 1.1 1.0 1. 1.5 1.9 1.7 1.9 13.3 13.7 13.3 13.6 14.0 14.5 14.0 14.3 14.7 15. HI PR 31 49 63 74 59 79 95 307 95 318 335 350 336 36 38 398 378 407 430 448 418 450 475 495 LO PR 105 11 1 130 111 118 19 138 116 13 134 143 11 19 141 150 17 135 148 157 13 140 153 163 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) conditions kw = Total system power High and low pressures are measured at the liquid and suction access fittings. Amps = outdoor unit amps (comp.+fan) Design Subcooling, 10 ± F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 9± F @ the compressor suction access fitting connection. 4 www.daikincomfort.com SS-DP13M

Expanded ooling Data DP13M3641A* (cont.) Outdoor Ambient Temperature 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 135 1180 965 MBh 34.5 35. 37.6 40. 33.7 34.4 36.8 39.3 3.9 33.6 35.9 38.4 3.1 3.8 35.0 37.4 30.5 31.1 33.3 35.5 8. 8.8 30.8 3.9 S/T 0.88 0.8 0.67 0.50 0.91 0.85 0.69 0.5 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.94 0.77 0.57 T 19 15 3 19 15 3 19 15 3 19 15 3 19 15 1 0 18 14 kw.5.57.65.73.70.76.84.93.86.9 3.01 3.11 3.01 3.07 3.17 3.7 3.13 3.19 3.9 3.40 3.3 3.30 3.41 3.5 Amps 10.8 11.0 11.3 11.7 11.5 11.7 1.1 1.4 1.3 1.6 1.9 13.4 13.1 13.3 13.7 14. 13.8 14.1 14.5 14.9 14.5 14.8 15. 15.7 HI PR 41 59 74 85 70 91 307 30 307 331 349 364 350 377 398 415 394 44 447 467 435 468 494 516 LO PR 110 117 17 136 116 13 135 143 10 18 140 149 16 135 147 156 133 141 154 164 137 146 159 170 MBh 34.5 35. 37.6 40. 33.7 34.4 36.8 39.3 3.9 33.6 35.9 38.4 3.1 3.8 35.0 37.4 30.5 31.1 33.3 35.5 8. 8.8 30.8 3.9 S/T 0.88 0.8 0.67 0.50 0.91 0.85 0.69 0.5 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.94 0.77 0.57 T 4 3 0 16 4 3 0 16 4 3 0 16 4 3 0 16 4 3 0 16 1 18 15 kw.5.57.65.73.70.76.84.93.86.9 3.01 3.11 3.01 3.07 3.17 3.7 3.13 3.19 3.9 3.40 3.3 3.30 3.41 3.5 Amps 10.8 11.0 11.3 11.7 11.5 11.7 1.1 1.4 1.3 1.6 1.9 13.4 13.1 13.3 13.7 14. 13.8 14.1 14.5 14.9 14.5 14.8 15. 15.7 HI PR 41 59 74 85 70 91 307 30 307 331 349 364 350 377 398 415 394 44 447 467 435 468 494 516 LO PR 110 117 17 136 116 13 135 143 10 18 140 149 16 135 147 156 133 141 154 164 137 146 159 170 MBh 31.8 3.5 34.7 37.1 31.1 31.7 33.9 36.3 30.3 31.0 33.1 35.4 9.6 30. 3.3 34.5 8.1 8.7 30.7 3.8 6.0 6.6 8.4 30.4 S/T 0.84 0.79 0.64 0.48 0.87 0.8 0.67 0.50 0.90 0.84 0.68 0.51 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 0.97 0.91 0.74 0.55 T 6 5 1 17 6 5 17 6 5 17 6 5 17 6 5 1 17 4 3 0 16 kw.46.51.59.66.64.69.77.86.80.85.94 3.03.93 3.00 3.09 3.19 3.05 3.1 3.1 3.3 3.15 3. 3.3 3.43 Amps 10.6 10.8 11.1 11.4 11.3 11.5 11.8 1. 1.1 1.3 1.6 13.0 1.8 13.0 13.4 13.8 13.4 13.7 14.1 14.6 14.1 14.4 14.8 15.3 HI PR 34 51 65 77 6 8 98 311 98 31 339 353 339 365 386 40 38 411 434 453 4 454 479 500 LO PR 106 113 14 13 11 10 131 139 117 14 136 144 13 131 14 15 19 137 149 159 133 141 154 165 85 135 1180 965 MBh 35.1 35.7 37.4 39.9 34.3 34.9 36.6 39.0 33.4 34.1 35.7 38.1 3.6 33.3 34.8 37. 31.0 31.6 33.1 35.3 8.7 9.3 30.6 3.7 S/T 0.9 0.89 0.80 0.65 0.95 0.9 0.83 0.67 0.98 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.9 0.74 T 4 4 19 4 4 3 0 4 4 3 0 4 4 3 0 3 4 19 1 1 18 kw.54.59.67.75.7.78.86.95.89.95 3.04 3.13 3.03 3.09 3.19 3.9 3.15 3. 3.3 3.43 3.6 3.33 3.43 3.55 Amps 10.9 11.1 11.4 11.7 11.6 11.8 1. 1.5 1.4 1.7 13.0 13.5 13. 13.4 13.8 14.3 13.9 14. 14.6 15.1 14.6 14.9 15.3 15.8 HI PR 43 6 76 88 73 94 310 33 310 334 353 368 353 380 40 419 398 48 45 471 439 473 499 51 LO PR 111 118 19 137 117 14 136 145 1 19 141 150 18 136 148 158 134 14 155 166 138 147 161 171 MBh 35.1 35.7 37.4 39.9 34.3 34.9 36.6 39.0 33.4 34.1 35.7 38.1 3.6 33.3 34.8 37. 31.0 31.6 33.1 35.3 8.7 9.3 30.6 3.7 S/T 0.9 0.89 0.80 0.65 0.95 0.9 0.83 0.67 0.98 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.9 0.74 T 5 5 3 0 5 5 4 0 5 5 4 0 5 5 4 1 4 5 3 0 3 19 kw.54.59.67.75.7.78.86.95.89.95 3.04 3.13 3.03 3.09 3.19 3.9 3.15 3. 3.3 3.43 3.6 3.33 3.43 3.55 Amps 10.9 11.1 11.4 11.7 11.6 11.8 1. 1.5 1.4 1.7 13.0 13.5 13. 13.4 13.8 14.3 13.9 14. 14.6 15.1 14.6 14.9 15.3 15.8 HI PR 43 6 76 88 73 94 310 33 310 334 353 368 353 380 40 419 398 48 45 471 439 473 499 51 LO PR 111 118 19 137 117 14 136 145 1 19 141 150 18 136 148 158 134 14 155 166 138 147 161 171 MBh 3.4 33.0 34.6 36.9 31.6 3. 33.8 36.0 30.9 31.5 3.9 35.1 30.1 30.7 3.1 34.3 8.6 9. 30.5 3.6 6.5 7.0 8.3 30. S/T 0.88 0.85 0.77 0.63 0.9 0.88 0.80 0.65 0.94 0.91 0.8 0.66 0.97 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 0.98 0.88 0.7 T 7 7 5 8 7 6 8 7 6 8 7 6 7 7 6 5 5 4 1 kw.48.53.61.68.66.71.80.88.8.88.96 3.06.96 3.0 3.11 3.1 3.08 3.14 3.4 3.34 3.18 3.5 3.35 3.46 Amps 10.6 10.9 11.1 11.5 11.3 11.6 11.9 1.3 1. 1.4 1.7 13.1 1.8 13.1 13.5 13.9 13.5 13.8 14. 14.7 14. 14.5 15.0 15.5 HI PR 36 54 68 80 65 85 301 314 301 34 34 357 343 369 390 406 386 415 438 457 46 459 484 505 LO PR 107 114 15 133 114 11 13 140 118 16 137 146 14 13 144 153 130 138 151 161 134 143 156 166 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions kw = Total system power High and low pressures are measured at the liquid and suction access fittings. Amps = outdoor unit amps (comp.+fan) Design Subcooling, 10 ± F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 9± F @ the compressor suction access fitting connection. SS-DP13M www.daikincomfort.com 5

Expanded ooling Data DP13M4841A* Outdoor Ambient Temperature 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1880 1675 1470 MBh 44.6 46. 50.6-43.5 45.1 49.5-4.5 44.1 48.3-41.5 43.0 47.1-39.4 40.8 44.7-36.5 37.8 41.4 - S/T 0.81 0.68 0.47-0.84 0.70 0.49-0.86 0.7 0.50-0.89 0.75 0.5-0.93 0.77 0.54-0.93 0.78 0.54 - T 18 15 1-18 16 1-18 16 1-18 16 1-18 15 1-17 14 11 - kw 3.1 3.19 3.8-3.35 3.4 3.53-3.56 3.63 3.74-3.73 3.81 3.94-3.89 3.97 4.10-4.0 4.11 4.4 - Amps 14.9 15. 15.6-15.9 16. 16.6-16.9 17. 17.7-17.8 18. 18.7-18.8 19.1 19.7-19.7 0.1 0.6 - HI PR 41 60 74-71 91 308-308 331 350-351 378 399-395 45 449-436 469 496 - LO PR 111 118 19-118 15 137-1 130 14-18 137 149-135 143 156-139 148 16 - MBh 43.3 44.9 49. - 4.3 43.8 48.0-41.3 4.8 46.9-40.3 41.7 45.7-38.3 39.6 43.4-35.4 36.7 40. - S/T 0.78 0.65 0.45-0.80 0.67 0.47-0.8 0.69 0.48-0.85 0.71 0.49-0.88 0.74 0.51-0.89 0.74 0.5 - T 18 16 1-19 16 1-19 16 1-19 16 1-19 16 1-17 15 11 - kw 3.10 3.16 3.6-3.33 3.40 3.50-3.53 3.60 3.71-3.71 3.78 3.90-3.86 3.94 4.06-3.99 4.07 4.0 - Amps 14.8 15.1 15.5-15.8 16.0 16.5-16.8 17.1 17.6-17.7 18.1 18.5-18.6 19.0 19.5-19.5 19.9 0.5 - HI PR 39 57 7-68 89 305-305 38 347-347 374 395-391 41 444-43 465 491 - LO PR 110 117 18-116 14 135-11 19 141-17 135 148-133 14 155-138 147 160 - MBh 40.0 41.4 45.4-39.0 40.4 44.3-38.1 39.5 43.3-37. 38.5 4. - 35.3 36.6 40.1-3.7 33.9 37.1 - S/T 0.75 0.63 0.43-0.78 0.65 0.45-0.80 0.66 0.46-0.8 0.69 0.47-0.85 0.71 0.49-0.86 0.7 0.50 - T 19 16 1-19 16 1-19 16 1-19 17 13-19 16 1-18 15 1 - kw 3.03 3.09 3.18-3.5 3.3 3.4-3.45 3.5 3.63-3.6 3.69 3.81-3.76 3.84 3.97-3.89 3.97 4.10 - Amps 14.5 14.8 15. - 15.4 15.7 16.1-16.4 16.8 17. - 17.3 17.7 18.1-18. 18.6 19.1-19.1 19.5 0.0 - HI PR 3 49 63-60 80 96-96 318 336-337 363 383-379 408 431-419 451 476 - LO PR 107 114 14-113 10 131-117 15 136-13 131 143-19 138 150-134 14 155-75 1880 1675 1470 MBh 45.3 46.7 50.5 54. 44.3 45.6 49.4 53.0 43. 44.5 48. 51.7 4. 43.4 47.0 50.4 40.1 41.3 44.7 47.9 37.1 38. 41.4 44.4 S/T 0.93 0.83 0.63 0.40 0.96 0.86 0.65 0.4 0.98 0.88 0.67 0.43 1.00 0.91 0.69 0.44 1.00 0.94 0.71 0.46 1.00 0.95 0.7 0.46 T 1 19 15 11 1 19 16 11 1 19 16 11 1 19 16 11 0 19 16 11 18 18 15 10 kw 3.15 3.1 3.31 3.41 3.38 3.45 3.56 3.67 3.58 3.66 3.77 3.90 3.77 3.85 3.97 4.10 3.9 4.00 4.13 4.7 4.05 4.14 4.7 4.41 Amps 15.1 15.3 15.7 16. 16.0 16.3 16.7 17. 17.0 17.4 17.8 18.4 18.0 18.3 18.8 19.4 18.9 19.3 19.8 0.4 19.8 0. 0.8 1.4 HI PR 44 6 77 89 74 94 311 34 311 335 354 369 354 381 403 40 399 49 453 473 441 474 501 5 LO PR 11 10 131 139 119 16 138 147 14 131 143 153 130 138 151 160 136 145 158 168 141 150 163 174 MBh 44.0 45.3 49.1 5.7 43.0 44.3 47.9 51.4 4.0 43. 46.8 50. 41.0 4. 45.6 49.0 38.9 40.1 43.4 46.5 36.0 37.1 40. 43.1 S/T 0.88 0.79 0.60 0.38 0.91 0.8 0.6 0.40 0.94 0.84 0.63 0.41 0.97 0.87 0.66 0.4 1.00 0.90 0.68 0.44 1.00 0.91 0.69 0.44 T 1 0 16 11 0 16 11 0 16 11 0 16 11 1 0 16 11 0 18 15 10 kw 3.1 3.19 3.8 3.38 3.35 3.4 3.53 3.64 3.56 3.63 3.75 3.86 3.74 3.81 3.94 4.06 3.89 3.97 4.10 4.3 4.0 4.11 4.4 4.38 Amps 15.0 15. 15.6 16.0 15.9 16. 16.6 17.1 16.9 17.3 17.7 18. 17.8 18. 18.7 19.3 18.8 19.1 19.7 0.3 19.7 0.1 0.6 1.3 HI PR 41 60 74 86 71 9 308 31 308 33 350 365 351 378 399 416 395 45 449 468 436 469 496 517 LO PR 111 118 19 138 118 15 137 146 1 130 14 151 18 137 149 159 135 143 156 167 139 148 16 17 MBh 40.6 41.8 45.3 48.6 39.7 40.9 44. 47.5 38.7 39.9 43. 46.3 37.8 38.9 4.1 45. 35.9 37.0 40.0 4.9 33.3 34. 37.1 39.8 S/T 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.38 0.90 0.81 0.61 0.39 0.93 0.83 0.63 0.41 0.97 0.87 0.66 0.4 0.98 0.87 0.66 0.43 T 0 16 11 0 17 11 0 17 11 0 17 11 0 16 11 0 19 15 11 kw 3.05 3.11 3.1 3.31 3.8 3.34 3.45 3.55 3.47 3.55 3.66 3.77 3.65 3.7 3.84 3.96 3.79 3.87 4.00 4.13 3.9 4.01 4.13 4.7 Amps 14.6 14.9 15.3 15.7 15.5 15.8 16. 16.7 16.6 16.9 17.3 17.8 17.5 17.8 18.3 18.8 18.3 18.7 19. 19.8 19. 19.6 0.1 0.8 HI PR 34 5 66 78 63 83 99 311 99 3 340 354 340 366 387 403 383 41 435 454 43 455 481 501 LO PR 108 115 15 134 114 11 133 141 119 16 138 147 15 133 145 154 131 139 15 16 135 144 157 167 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) conditions kw = Total system power High and low pressures are measured at the liquid and suction access fittings. Amps = outdoor unit amps (comp.+fan) Design Subcooling, 10 ± F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 10± F @ the compressor suction access fitting connection. 6 www.daikincomfort.com SS-DP13M

Expanded ooling Data DP13M4841A* (cont.) Outdoor Ambient Temperature 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1880 1675 1470 MBh 46.1 47. 50.4 53.9 45.1 46.1 49. 5.6 44.0 45.0 48.0 51.4 4.9 43.9 46.9 50.1 40.8 41.7 44.5 47.6 37.8 38.6 41. 44.1 S/T 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.8 0.6 1.00 1.00 0.85 0.63 1.00 1.00 0.88 0.66 1.00 1.00 0.89 0.66 T 3 19 15 3 19 15 19 15 1 1 19 16 0 0 19 15 18 19 18 14 kw 3.17 3.4 3.33 3.44 3.41 3.48 3.58 3.70 3.61 3.69 3.81 3.93 3.80 3.88 4.00 4.13 3.95 4.04 4.17 4.30 4.08 4.17 4.31 4.45 Amps 15. 15.4 15.8 16.3 16.1 16.4 16.8 17.3 17. 17.5 18.0 18.5 18.1 18.5 19.0 19.5 19.0 19.4 0.0 0.6 0.0 0.4 0.9 1.6 HI PR 46 65 80 9 76 97 314 38 314 338 357 373 358 385 407 44 403 433 458 477 445 479 506 57 LO PR 114 11 13 141 10 18 139 148 15 133 145 154 131 139 15 16 137 146 160 170 14 151 165 176 MBh 44.8 45.8 48.9 5.3 43.8 44.7 47.8 51.1 4.7 43.7 46.6 49.9 41.7 4.6 45.5 48.6 39.6 40.5 43. 46. 36.7 37.5 40.0 4.8 S/T 0.97 0.91 0.74 0.55 1.00 0.94 0.77 0.57 1.00 0.96 0.78 0.59 1.00 1.00 0.81 0.61 1.00 1.00 0.84 0.63 1.00 1.00 0.85 0.63 T 4 3 0 16 4 3 0 16 3 3 0 16 3 3 0 16 0 16 0 1 19 15 kw 3.15 3.1 3.31 3.41 3.38 3.45 3.56 3.67 3.58 3.66 3.78 3.90 3.77 3.85 3.97 4.10 3.9 4.00 4.13 4.7 4.05 4.14 4.7 4.41 Amps 15.1 15.3 15.7 16. 16.0 16.3 16.7 17. 17.1 17.4 17.8 18.4 18.0 18.3 18.8 19.4 18.9 19.3 19.8 0.4 19.8 0. 0.8 1.4 HI PR 44 6 77 89 74 94 311 34 311 335 354 369 354 381 403 40 399 49 453 473 441 474 501 5 LO PR 11 10 131 139 119 16 138 147 14 131 143 153 130 138 151 160 136 145 158 168 141 150 163 174 MBh 41.4 4.3 45.1 48.3 40.4 41.3 44.1 47.1 39.4 40.3 43.0 46.0 38.5 39.3 4.0 44.9 36.5 37.3 39.9 4.6 33.9 34.6 37.0 39.5 S/T 0.93 0.88 0.71 0.53 0.97 0.91 0.74 0.55 0.99 0.93 0.76 0.57 1.0 0.96 0.78 0.58 1.06 1.00 0.81 0.61 1.07 1.00 0.8 0.61 T 4 3 0 16 4 3 0 16 4 3 0 16 5 4 1 16 4 3 0 16 3 19 15 kw 3.08 3.14 3.3 3.33 3.30 3.37 3.47 3.58 3.50 3.57 3.68 3.80 3.68 3.75 3.87 4.00 3.8 3.91 4.03 4.16 3.95 4.04 4.17 4.30 Amps 14.7 15.0 15.4 15.8 15.6 15.9 16.3 16.8 16.7 17.0 17.4 18.0 17.6 17.9 18.4 19.0 18.5 18.8 19.4 0.0 19.4 19.8 0.3 0.9 HI PR 37 55 69 80 65 86 30 315 30 35 343 358 344 370 391 408 387 416 440 458 47 460 486 507 LO PR 109 116 17 135 115 13 134 143 10 17 139 148 16 134 146 156 13 140 153 163 136 145 158 169 85 1880 1675 1470 MBh 47.0 47.9 50.1 53.5 45.9 46.7 49.0 5. 44.8 45.6 47.8 51.0 43.7 44.5 46.6 49.7 41.5 4.3 44.3 47.3 38.4 39. 41.0 43.8 S/T 1.00 1.00 0.93 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.98 0.80 1.00 1.00 1.00 0.8 1.00 1.00 1.00 0.86 1.00 1.00 1.00 0.86 T 3 3 3 0 3 3 0 3 0 1 3 0 0 1 0 19 19 0 18 kw 3.0 3.6 3.36 3.46 3.43 3.50 3.61 3.73 3.64 3.7 3.84 3.96 3.83 3.91 4.03 4.16 3.98 4.07 4.0 4.34 4.1 4.1 4.34 4.49 Amps 15.3 15.5 15.9 16.4 16. 16.5 16.9 17.4 17.3 17.6 18.1 18.6 18. 18.6 19.1 19.7 19. 19.6 0.1 0.7 0.1 0.5 1.1 1.8 HI PR 49 68 83 95 79 300 317 331 317 34 361 376 36 389 411 49 407 438 46 48 449 484 511 533 LO PR 115 1 133 14 11 19 141 150 16 134 146 156 13 141 154 164 139 148 161 17 143 153 167 177 MBh 45.6 46.5 48.7 51.9 44.5 45.4 47.5 50.7 43.5 44.3 46.4 49.5 4.4 43. 45.3 48.3 40.3 41.1 43.0 45.9 37.3 38.0 39.8 4.5 S/T 1.00 0.98 0.88 0.7 1.00 1.00 0.9 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.97 0.79 1.00 1.00 1.00 0.8 1.00 1.00 1.00 0.8 T 5 5 4 0 4 5 4 1 4 4 4 1 3 4 4 1 3 4 1 0 1 19 kw 3.17 3.4 3.33 3.44 3.41 3.48 3.58 3.70 3.61 3.69 3.81 3.93 3.80 3.88 4.00 4.13 3.95 4.04 4.17 4.30 4.08 4.17 4.31 4.45 Amps 15. 15.4 15.8 16.3 16.1 16.4 16.8 17.3 17. 17.5 18.0 18.5 18.1 18.5 19.0 19.5 19.0 19.4 0.0 0.6 0.0 0.4 0.9 1.6 HI PR 46 65 80 9 76 97 314 38 314 338 357 373 358 385 407 44 403 433 458 477 445 479 506 57 LO PR 114 11 13 141 10 18 139 148 15 133 145 154 131 139 15 16 137 146 160 170 14 151 165 176 MBh 4.1 4.9 44.9 47.9 41.1 41.9 43.9 46.8 40.1 40.9 4.8 45.7 39.1 39.9 41.8 44.6 37. 37.9 39.7 4.4 34.4 35.1 36.8 39. S/T 0.98 0.94 0.85 0.69 1.00 0.98 0.88 0.7 1.00 1.00 0.91 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.97 0.79 1.00 1.00 0.98 0.79 T 6 5 4 1 6 6 4 1 5 6 4 1 4 5 4 1 3 4 4 1 19 kw 3.10 3.16 3.6 3.36 3.33 3.40 3.50 3.61 3.53 3.60 3.71 3.83 3.70 3.78 3.90 4.03 3.85 3.94 4.06 4.0 3.98 4.07 4.0 4.34 Amps 14.8 15.1 15.5 15.9 15.8 16.0 16.5 16.9 16.8 17.1 17.6 18.1 17.7 18.1 18.5 19.1 18.6 19.0 19.5 0.1 19.5 19.9 0.4 1.1 HI PR 39 57 7 83 68 89 305 318 305 38 346 361 347 374 395 41 391 40 444 463 43 465 491 51 LO PR 110 117 18 136 116 14 135 144 11 19 141 150 17 135 148 157 133 14 155 165 138 147 160 170 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions kw = Total system power High and low pressures are measured at the liquid and suction access fittings. Amps = outdoor unit amps (comp.+fan) Design Subcooling, 10 ± F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 10± F @ the compressor suction access fitting connection. SS-DP13M www.daikincomfort.com 7

Expanded ooling Data DP13M6041A* Outdoor Ambient Temperature 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1965 1789 1535 MBh 53.8 55.8 61.1-5.6 54.5 59.7-51.3 53. 58.3-50.1 51.9 56.8-47.6 49.3 54.0-44.0 45.7 50.0 - S/T 0.74 0.6 0.43-0.77 0.64 0.45-0.79 0.66 0.46-0.81 0.68 0.47-0.85 0.71 0.49-0.85 0.71 0.49 - T 19 16 1-19 16 1-19 16 1-19 17 13-19 16 1-18 15 1 - kw 3.98 4.07 4.19-4.9 4.38 4.5-4.55 4.65 4.80-4.79 4.89 5.05-4.99 5.10 5.7-5.16 5.8 5.45 - Amps 18.6 18.9 19.4-19.8 0. 0.7-1. 1.6. -.4.8 3.5-3.6 4.1 4.7-4.8 5.3 6.0 - HI PR 36 54 68-65 85 301-301 34 34-343 369 389-386 415 438-46 458 484 - LO PR 104 110 11-110 117 17-114 11 13-10 17 139-16 134 146-130 138 151 - MBh 53.3 55. 60.5-5.0 53.9 59.1-50.8 5.7 57.7-49.6 51.4 56.3-47.1 48.8 53.5-43.6 45. 49.5 - S/T 0.73 0.61 0.4-0.75 0.63 0.44-0.77 0.65 0.45-0.80 0.67 0.46-0.83 0.69 0.48-0.84 0.70 0.48 - T 0 17 13-0 17 13-0 17 13-0 18 13-0 17 13-19 16 1 - kw 3.97 4.06 4.18-4.8 4.37 4.51-4.54 4.64 4.79-4.78 4.88 5.04-4.98 5.09 5.6-5.15 5.7 5.44 - Amps 18.5 18.9 19.4-19.7 0.1 0.7-1.1 1.5.1 -.3.8 3.4-3.5 4.0 4.7-4.7 5. 5.9 - HI PR 35 53 67-64 84 300-300 33 341-34 368 388-384 414 437-45 457 483 - LO PR 104 110 10-109 116 17-114 11 13-119 17 139-15 133 145-19 138 150 - MBh 49. 51.0 55.8-48.0 49.8 54.5-46.9 48.6 53. - 45.7 47.4 51.9-43.5 45.0 49.3-40.3 41.7 45.7 - S/T 0.70 0.59 0.41-0.73 0.61 0.4-0.75 0.6 0.43-0.77 0.64 0.45-0.80 0.67 0.46-0.81 0.67 0.47 - T 1 18 14-1 18 14-1 18 14-1 18 14-1 18 14-19 17 13 - kw 3.88 3.96 4.08-4.17 4.6 4.40-4.43 4.53 4.67-4.66 4.76 4.9-4.85 4.96 5.1-5.0 5.13 5.30 - Amps 18.1 18.5 19.0-19.3 19.7 0. - 0.6 1.1 1.6-1.8..9-3.0 3.4 4.1-4.1 4.6 5.3 - HI PR 8 45 59-56 75 91-91 313 331-331 357 377-373 401 44-41 443 468 - LO PR 100 107 117-106 113 13-110 117 18-116 13 135-11 19 141-16 134 146-75 1965 1789 1535 MBh 54.7 56.3 61.0 65.5 53.4 55.0 59.6 63.9 5. 53.7 58.1 6.4 50.9 5.4 56.7 60.9 48.4 49.8 53.9 57.8 44.8 46.1 49.9 53.6 S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.96 0.86 0.65 0.4 0.97 0.87 0.66 0.4 T 0 16 11 0 17 11 0 17 11 0 17 11 0 16 11 0 19 15 11 kw 4.0 4.10 4.3 4.36 4.3 4.41 4.55 4.70 4.59 4.69 4.84 5.00 4.83 4.94 5.10 5.7 5.03 5.14 5.31 5.49 5.1 5.3 5.50 5.69 Amps 18.7 19.1 19.6 0. 19.9 0.3 0.9 1.5 1.3 1.8.4 3.1.5 3.0 3.6 4.4 3.8 4.3 4.9 5.8 5.0 5.5 6. 7.1 HI PR 38 56 71 8 67 88 304 317 304 37 345 360 346 373 393 410 389 419 443 46 430 463 489 510 LO PR 105 11 1 130 111 118 19 137 115 13 134 143 11 19 141 150 17 135 147 157 131 140 15 16 MBh 54. 55.8 60.4 64.8 5.9 54.5 59.0 63.3 51.7 53. 57.6 61.8 50.4 51.9 56. 60.3 47.9 49.3 53.4 57.3 44.4 45.7 49.4 53.0 S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.81 0.61 0.40 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41 T 3 1 17 1 3 1 18 1 3 18 1 4 18 1 3 1 17 1 0 16 11 kw 4.01 4.09 4. 4.35 4.31 4.40 4.54 4.69 4.58 4.68 4.83 4.99 4.8 4.9 5.08 5.5 5.0 5.13 5.30 5.48 5.19 5.31 5.49 5.67 Amps 18.7 19.0 19.5 0.1 19.9 0.3 0.8 1.5 1.3 1.7.3 3.0.5 3.0 3.6 4.3 3.7 4. 4.9 5.7 4.9 5.4 6. 7.0 HI PR 37 56 70 81 66 87 303 316 303 36 344 359 345 371 39 409 388 418 441 460 49 46 488 509 LO PR 105 111 11 19 111 118 18 137 115 1 133 14 11 18 140 149 16 135 147 156 131 139 15 16 MBh 50.0 51.5 55.7 59.8 48.8 50.3 54.4 58.4 47.7 49.1 53.1 57.0 46.5 47.9 51.8 55.6 44. 45.5 49.3 5.9 40.9 4.1 45.6 49.0 S/T 0.80 0.71 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.91 0.81 0.6 0.40 0.9 0.8 0.6 0.40 T 4 18 1 4 18 13 4 18 13 4 18 13 4 18 13 1 17 1 kw 3.91 3.99 4.1 4.5 4.1 4.30 4.43 4.58 4.47 4.56 4.71 4.87 4.70 4.80 4.96 5.1 4.90 5.00 5.17 5.34 5.06 5.18 5.35 5.53 Amps 18.3 18.6 19.1 19.7 19.4 19.8 0.3 1.0 0.8 1. 1.8.5.0.4 3.0 3.8 3.1 3.6 4.3 5.1 4.3 4.8 5.5 6.4 HI PR 30 48 6 73 58 78 94 306 94 316 334 348 335 360 380 397 377 405 48 446 416 448 473 493 LO PR 101 108 118 16 107 114 15 133 111 119 19 138 117 15 136 145 13 130 14 15 17 135 147 157 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) conditions kw = Total system power High and low pressures are measured at the liquid and suction access fittings. Amps = outdoor unit amps (comp.+fan) Design Subcooling, 9 ± F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 10± F @ the compressor suction access fitting connection. 8 www.daikincomfort.com SS-DP13M

Expanded ooling Data DP13M6041A* (cont.) Outdoor Ambient Temperature 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1965 1789 1535 MBh 55.7 56.9 60.8 65.0 54.4 55.6 59.4 63.5 53.1 54.3 58.0 6.0 51.8 5.9 56.6 60.5 49. 50.3 53.7 57.4 45.6 46.6 49.8 53. S/T 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 0.98 0.9 0.75 0.56 1.00 0.95 0.78 0.58 1.00 0.99 0.80 0.60 1.00 1.00 0.81 0.61 T 4 3 0 16 4 3 0 16 4 3 0 16 4 4 1 16 3 3 0 16 1 19 15 kw 4.05 4.13 4.6 4.40 4.36 4.45 4.59 4.74 4.63 4.73 4.88 5.04 4.87 4.98 5.14 5.31 5.07 5.19 5.36 5.54 5.5 5.37 5.55 5.73 Amps 18.8 19. 19.7 0.3 0.1 0.5 1.0 1.7 1.5 1.9.5 3..7 3. 3.8 4.6 3.9 4.4 5.1 6.0 5. 5.7 6.4 7.3 HI PR 41 59 73 85 70 91 307 30 307 330 349 364 350 376 397 414 393 43 447 466 435 468 494 515 LO PR 106 113 13 131 11 119 130 139 116 14 135 144 1 130 14 151 18 136 149 158 133 141 154 164 MBh 55.1 56.3 60. 64.4 53.9 55.0 58.8 6.9 5.6 53.7 57.4 61.4 51.3 5.4 56.0 59.9 48.7 49.8 53. 56.9 45.1 46.1 49.3 5.7 S/T 0.91 0.85 0.69 0.5 0.94 0.88 0.7 0.54 0.96 0.90 0.74 0.55 1.00 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 0.98 0.80 0.59 T 6 5 1 17 6 5 17 6 5 17 6 5 17 5 5 17 3 3 0 16 kw 4.04 4.1 4.5 4.39 4.35 4.44 4.58 4.73 4.6 4.7 4.87 5.03 4.86 4.96 5.13 5.30 5.06 5.17 5.34 5.5 5.4 5.36 5.53 5.7 Amps 18.8 19. 19.7 0.3 0.0 0.4 1.0 1.6 1.4 1.9.5 3..7 3.1 3.8 4.5 3.9 4.4 5.1 5.9 5.1 5.6 6.4 7. HI PR 40 58 73 84 69 90 306 319 306 39 348 363 349 375 396 413 39 4 446 465 433 466 49 514 LO PR 106 11 13 131 11 119 130 138 116 13 135 144 1 130 14 151 18 136 148 158 13 141 153 163 MBh 50.9 5.0 55.6 59.4 49.7 50.8 54.3 58.0 48.5 49.6 53.0 56.6 47.3 48.4 51.7 55.3 45.0 46.0 49.1 5.5 41.7 4.6 45.5 48.6 S/T 0.88 0.8 0.67 0.50 0.91 0.85 0.69 0.5 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.94 0.77 0.57 T 7 6 18 7 6 3 18 7 6 3 18 7 6 3 18 7 6 18 5 4 1 17 kw 3.94 4.0 4.15 4.8 4.4 4.33 4.47 4.61 4.50 4.60 4.75 4.91 4.74 4.84 5.00 5.16 4.94 5.04 5.1 5.38 5.11 5. 5.39 5.57 Amps 18.4 18.7 19. 19.8 19.6 0.0 0.5 1.1 1.0 1.4.0.6.1.6 3. 4.0 3.3 3.8 4.5 5.3 4.5 5.0 5.7 6.6 HI PR 33 50 64 76 61 81 97 309 97 30 337 35 338 364 384 401 380 409 43 451 40 45 478 498 LO PR 10 109 119 17 108 115 16 134 113 10 131 139 118 16 137 146 14 13 144 153 18 136 149 159 85 1965 1789 1535 MBh 56.7 57.8 60.5 64.5 55.3 56.4 59.1 63.0 54.0 55.1 57.7 61.5 5.7 53.7 56.3 60.0 50.1 51.0 53.5 57.0 46.4 47.3 49.5 5.8 S/T 0.97 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.93 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.79 T 6 5 4 1 6 6 4 1 5 6 4 1 5 5 4 1 3 4 4 1 19 kw 4.08 4.16 4.30 4.43 4.39 4.49 4.63 4.78 4.67 4.77 4.9 5.09 4.91 5.0 5.18 5.36 5.1 5.3 5.40 5.59 5.30 5.41 5.59 5.78 Amps 19.0 19.3 19.9 0.5 0. 0.6 1. 1.8 1.7.1.7 3.4.9 3.4 4.0 4.8 4.1 4.6 5.3 6. 5.4 5.9 6.6 7.5 HI PR 43 6 76 88 73 93 310 33 310 334 35 368 353 380 401 419 397 48 45 471 439 47 499 50 LO PR 107 114 14 13 113 10 131 140 118 15 137 145 13 131 143 153 19 138 150 160 134 14 155 166 MBh 56.1 57. 59.9 63.9 54.8 55.9 58.5 6.4 53.5 54.5 57.1 60.9 5. 53. 55.7 59.4 49.6 50.5 5.9 56.5 45.9 46.8 49.0 5.3 S/T 0.95 0.9 0.83 0.67 0.99 0.95 0.86 0.70 1.00 0.98 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.77 1.00 1.00 0.95 0.77 T 7 7 6 8 7 6 7 7 6 7 7 6 3 5 6 6 4 4 4 1 kw 4.07 4.15 4.9 4.4 4.38 4.47 4.6 4.77 4.66 4.76 4.91 5.07 4.90 5.01 5.17 5.34 5.10 5. 5.39 5.57 5.8 5.40 5.58 5.77 Amps 18.9 19.3 19.8 0.4 0. 0.6 1.1 1.8 1.6.0.7 3.4.8 3.3 4.0 4.7 4.1 4.6 5.3 6.1 5.3 5.8 6.6 7.5 HI PR 4 61 75 87 7 93 309 3 309 333 351 366 35 379 400 417 396 46 450 470 438 471 497 519 LO PR 107 114 14 13 113 10 131 139 117 15 136 145 13 131 143 15 19 137 150 160 133 14 155 165 MBh 51.8 5.8 55.3 59.0 50.6 51.6 54.0 57.6 49.4 50.3 5.7 56. 48. 49.1 51.4 54.9 45.8 46.7 48.9 5.1 4.4 43. 45.3 48.3 S/T 0.9 0.89 0.80 0.65 0.95 0.9 0.83 0.67 0.98 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.9 0.74 T 8 8 6 3 9 8 7 3 9 8 7 3 9 9 7 3 7 8 7 3 5 6 5 kw 3.97 4.06 4.18 4.3 4.7 4.37 4.50 4.65 4.54 4.64 4.79 4.95 4.78 4.88 5.04 5.1 4.98 5.09 5.5 5.43 5.15 5.6 5.44 5.6 Amps 18.5 18.9 19.4 0.0 19.7 0.1 0.7 1.3 1.1 1.5.1.8.3.8 3.4 4.1 3.5 4.0 4.7 5.5 4.7 5. 5.9 6.8 HI PR 35 53 67 79 64 84 300 313 300 33 341 355 34 368 388 405 384 414 437 455 45 457 48 503 LO PR 104 110 10 18 109 116 17 135 114 11 13 141 119 17 139 148 15 133 145 155 19 138 150 160 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions kw = Total system power High and low pressures are measured at the liquid and suction access fittings. Amps = outdoor unit amps (comp.+fan) Design Subcooling, 9 ± F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 10± F @ the compressor suction access fitting connection. SS-DP13M www.daikincomfort.com 9

Airflow Data Model Motor Tap Speed Volts E.S.P (In. of H O) 0.1 0. 0.3 0.4 0.5 0.6 0.7 0.8 DP13M 3641** DP13M 4841** DP13M 6041** Low 30 Med 30 High 30 T1 30 T / T3 30 T4 / T5 30 T1 30 T / T3 30 T4 / T5 30 FM 1,1 1,078 1,03 97 915 804 687 558 Watts 338 330 31 310 300 83 64 50 FM 1,387 1,331 1,64 1,09 1,119 1,041 935 748 Watts 456 440 48 41 399 38 363 330 FM 1,51 1,454 1,388 1,311 1,30 1,144 1,055 939 Watts 534 51 510 490 477 461 44 40 FM 1,451 1,404 1,356 1,309 1,6 1,15 1,168 1,11 Watts 55 64 73 8 91 99 308 317 FM 1,809 1,76 1,715 1,667 1,60 1,573 1,56 1,479 Watts 444 453 46 471 479 488 497 506 FM 1,885 1,838 1,790 1,743 1,696 1,649 1,60 1,555 Watts 484 493 50 510 519 58 537 546 FM 1,774 1,731 1,688 1,645 1,60 1,559 1,515 1,47 Watts 444 453 463 473 483 493 503 51 FM 1,891 1,848 1,804 1,761 1,718 1,675 1,63 1,589 Watts 515 55 535 544 554 564 574 584 FM,105,06,018 1,975 1,93 1,889 1,846 1,803 Watts 646 656 666 676 686 696 705 715 Notes Data shown is dry coil. Wet coil pressure drop is approximately 0.1 H₂O, for two-row indoor coil; 0. H₂O, for three-row indoor coil; and 0.3 H₂O, for four-row indoor coil. Data shown does not include filter pressure drop, approx. 0.08 H₂O. ALL MODELS SHOULD RUN NO LESS THAN 350 FM/TON. USE HIGHER SPEED TAP OR NEXT SIZE LARGER OWER ASM. See Repair Parts list. Reduce airflow by % for 08-volt operation. 10 www.daikincomfort.com SS-DP13M

Heat Kit Electrical Data (Blower Only, Heat Mode) Model and Heat Kit Usage ircuit #1 ircuit # Single-Point Kit Actual kw / BTU@ 40V MA¹ MOP² MA¹ MOP² MA¹ MOP² DP13M3641** 1.9 --- --- --- -- -- --- HKR-05*, HKR-05* 1 / 5 5 / 5 --- --- 5 40 4.75 / 16,00 HKR-08*, HKR-08* 3 / 36 35 / 40 --- --- 34 / 39 40 / 40 7.0 / 3,800 HKR-10*, HKR-10* 43 / 49 45 / 50 --- --- 45 / 5 60 / 60 9.5 / 3,400 HKP-15* 43 / 49 45 / 50 1 / 5 5 / 5 66 / 76 70 / 80 14.5 / 48,600 DP13M4841** 7.3 --- --- --- -- -- --- HKR-05*, HKR-05* 1 / 5 5 / 5 --- --- 3 50 4.75 / 16,00 HKR-08*, HKR-08* 3 / 36 35 / 40 --- --- 38 / 40 50 7.0 / 3,800 HKR-10*, HKR-10* 43 / 49 45 / 50 --- --- 49 / 56 60 / 60 9.5 / 3,400 HKP-15* 43 / 49 45 / 50 1 / 5 5 / 5 70 / 80 80 / 90 14.5 / 48,600 HKP-0 43 / 49 45 / 50 43 / 49 45 / 50 9 / 105 100 / 110 19.0 / 64,800 DP13M6041** 9.5 --- --- --- -- -- --- HKR-05*, HKR-05* 1 / 5 5 / 5 --- --- 4 60 4.75 / 16,00 HKR-08*, HKR-08* 3 / 36 35 / 40 --- --- 4 60 7.0 / 3,800 HKR-10*, HKR-10* 43 / 49 45 / 50 --- --- 51 / 58 60 / 60 9.5 / 3,400 HKP-15* 43 / 49 45 / 50 1 / 5 5 / 5 7 / 8 80 / 90 14.5 / 48,600 HKP-0 43 / 49 45 / 50 43 / 49 45 / 50 93 / 107 100 / 110 19.0 / 64,800 ¹ Minimum ircuit Ampacity @ 08 / 40 V ² Maximum Overcurrent Protection Device @ 08 / 40 V * Revision level that may or may not be designated ircuit breaker option Note: HKP-15* and HKP-0* replace HKR-15 and HKR-0 respectively to meet new UL1995 requirements. Single-Point Kit Accessory Kits Select the single-point kit accessory based on the unit model. Model DP13M3641** DP13M4841** DP13M6041** Single-Point Kit SPK-40 SPK-50 SPK-60 SS-DP13M www.daikincomfort.com 11

Temperature Rise Range hart 100 90 80 70 60 50 40 30 0 10 BTU OUTT vs TEMPERATURE RISE HART 600 FM 700 800 900 1000 1100 100 1400 1600 1800 000 00 400 FM FORMULAS BTU BTU/h OUTT Output = = FM FRM x 1.08 x x Rise RISE RISE Rise = = Formulas BTU OUTT BTU/H Output 1.08 FM x 1.08 FM FM 30 40 50 60 70 80 90 100 110 10 130 140 150 OUTT Output BTU/h BTU/HR x 1,000 x 1000 TEMPERATURE Temperature Rise RISE 1 www.daikincomfort.com SS-DP13M

Dimensions A B Model hassis Size Dimensions ( ) Med. Large H x D x W A B DP13M3641** X 34¾ x 51 x 47 3 16 DP13M4841** X 4¾ x 51 x 47 40 18 DP13M6041** X 4¾ x 51 x 47 40 18 SS-DP13M www.daikincomfort.com 13

Wiring Diagram DP13M3641** L1 1 F M1 EBTDR M 3 4 P L 4 5 6 G EBTDR R XFMR-R XFMR- SPEED UP EM 3 SPEED 3 1 4 SA (IF USED) SEE NOTE 5 K1 K1 M1 1 08 NO OM N M SUPPLY VOLTAGE 08-40/1/60 H SEE NOTE #3 T R T1 OMP RF S H F S.A. NOTE #5 M EM NOTE# EBTDR OM F 1 3 NOTE #4 3 P L F N EBTDR NO 08-40 4V TR R G HPS R W W1 Y G H 4V (TRANS40V) (M1) F F RF 3 40 PLF 3 6 1 NOTE #4 LOW (OM) HIGH EM SPEED OPTIONAL L 5 4 9 8 7 M OMPONENT LEGEND H M OMP EBTD R EM F GND LVJB PLF RF SA TR HPS NOTES: T T1 S R OMP L L1 WH /PNK /PNK H NOTE #3 OWER INTERLOK RELAY ONTATOR RANKASE HEATER ONDENSER MOTOR OMPRESSOR ELETRONI OWER TIME DELAY RELAY EVAPORATOR MOTOR FAN APAITOR EQUIPMENT OUND LOW VOLTAGE JUNTION BOX FEMALE PLUG / ONNETOR RUN APAITOR FOR OMPRESSOR AND FAN START ASSIST TRANSFORMER HIGH PRESSURE SWITH SEE NOTE #6 GND LVJB HPS SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER URRENT PROTETION T Y H R E G R W1 M O S W + + FATORY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE 0 8-4 0 / 1 / 60 T A T ONTROL BOX WIRE ODE AK UE OWN EEN OR ORANGE RPLE RED WH WHITE YELLOW /PNK UE/PINK STRIPE 1. REPLAEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105 ) USE OPPER ONDUTOR ONLY.. TO HANGE EVAPORATOR MOTOR SPEED REPLAE LEAD ON EBTDR "OM" WITH LEAD ON EBTDR "M1" OR "M" 3. RANKASE HEAT NOT SUPPLIED ON ALL UNITS. 4. FOR 08 VOLT TRANSFORMER OPERATION MOVE RPLE WIRES FROM TERMINAL 3 TERMINAL ON TRANSFORMER. 5. START ASSIST FATOR EQUIPPED WHEN REQUIRED 6. USE OPPER ONDUTORS ONLY ++ USE N.E.. LASS WIRE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram or the Warning unit for the most up-to-date wiring. THERMOSTAT 08-40/1/60 0140G0135 REV. A 14 www.daikincomfort.com SS-DP13M

Wiring Diagram DP1348-6041** L1 L G N 1 3 4 5 SEE NOTE N 4 5 6 PLF 1 T1 NOTE # EM G EM SUPPLY VOLTAGE 08-40/1/60 OMP S.A. IF USED 3 R S L H RF T NOTE #4 08-40 NOTE #3 3 1 F 4V WH TR M 3 1 EM HPS H 1 L 08 4V F RF TR SEE NOTE # 3 40 3 1 PLF NOTE #3 6 5 4 SA (IF USED) SEE NOTE 4 WH 9 8 7 M OMPONENT LEGEND M OMP EM GND LVJB PLF RF SA TR HPS NOTES: T T1 S R OMP L L1 LVJB WH /PNK /PNK HPS ONTATOR ONDENSER MOTOR OMPRESSOR EVAPORATOR MOTOR EQUIPMENT OUND LOW VOLTAGE JUNTION BOX FEMALE PLUG / ONNETOR RUN APAITOR FOR OMPRESSOR AND FAN START ASSIST TRANSFORMER HIGH PRESSURE SWITH OR WH /PNK SEE NOTE 5 GND Y R G W1 W ++ 0 8-4 0 / 1 / 60 T H E R M O S T A T ONTROL BOX FATORY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE ODE AK UE OWN EEN ORANGE RPLE RED WHITE YELLOW UE/PINK STRIPE 1. REPLAEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105 ) USE OPPER ONDUTOR ONLY.. TO HANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM EM"" AND "3" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED. 3. FOR 08 VOLT TRANSFORMER OPERATION MOVE RPLE WIRES FROM TERMINAL 3 TO TERMINAL ON TRANSFORMER. 4. START ASSIST FATOR EQUIPED WHEN REQUIRED 5. USE OPPER ONDUTORS ONLY ++ USE N.E.. LASS WIRE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram or the Warning unit for the most up-to-date wiring. R W W1 Y G THERMOSTAT SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER URRENT PROTETION 08-40/1/60 0140G01077 REV A SS-DP13M www.daikincomfort.com 15

Accessories Accessory Description Medium hassis Item Number oncentric Kit DK36 DK487 Large hassis Downflow Economizer DDNENJPHMM DDNENJPHML Downflow Internal Filter Rack DDNIFRPHMM DDNIFRPHML Downflow Manual Damper DDN5FDPGHMM DDN5FDPGHML Downflow Motorized Damper DDN5MFDPGHMM DDN5MFDPGHML Downflow Square to Round SQRPG101/10 SQRPG103 External Horizontal Filter Rack DPHFRA DPHFRA Horizontal Duct over 0464501NGK 046450NGK Horizontal Economizer DHZENJPGHM DHZENJPGHL Horizontal Manual Damper DHZ5FDPGHMM DHZ5FDPGHML Horizontal Motorized Damper DHZ5MFDPGHMM DHZ5MFDPGHML Horizontal Square to Round SQRPGH101/10 SQRPGH103 Outdoor Thermostat & Emergency Heat Relay Kit OT/EHR18-60 OT/EHR18-60 Outdoor Thermostat Kit w/ Lockout Stat OT18-60A OT18-60A Roof urb D14RBPGHMA D14RBPGHMA Our continuing commitment to quality products may mean a change in specifications without notice. 013 Houston, Texas Printed in the USA. 16 www.daikincomfort.com SS-DP13M