INSTALLATION MANUAL. PrimeFire#2 PF x 1 x 1 x 1. Manufactured by: Planika Sp. z o.o. ul. Bydgoska Brzoza Poland

Similar documents
INSTALLATION MANUAL. PrimeBox REMOTE. Ø8x60. x 1 H L 875 L1 762 L2 56,5 D 325 H2

presents PRICE LIST PLANIKA 2015

push button fireplaces collection Eco mode: 22,5 m 2 with a height of 2,6 m Normal mode: 34 m 2 with a height of 2,6 m 806 mm x 359 mm x 206 mm

INTELLIGENT FIREPLACES COLLECTION

INTELLIGENT FIREPLACES COLLECTION

INTELLIGENT FIREPLACES

GAS FIREPLACES. indoor and outdoor

GAS FIREPLACES

SP6. Automatic Battery Charger. Model

Installation Manual. English. French

P90L-ISO6MB & ISO10MB

Model: SPTOGT01 TRACTOR PTO GENERATOR

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

Lumitester PD-20 Control Kit

PRICE LIST PLANIKA 2017

OWNER'S MANUAL WARNING DANGER. Propane cylinders sold separately. The propane cylinder must be disconnected when this firebowl is not use.

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

HOT AIR GUN MODEL No. CHG 1500B Part No

Model: SE-4020-CA Automatic Battery Charger

Models: SP3, SPSS3 Automatic Battery Charger

BR133AE BR135AE. Random orbital sanders with dust extraction OPERATING AND MAINTENANCE INSTRUCTIONS

Voltmaster Centrifugal Trash Pumps

AXIAL FANS Axis / Tubo OPERATION MANUAL

ATM Lighting sp. z o.o

POWERSOURCEPURE INSTRUCTIONS. Pure Sine Wave Inverter. RINV1200P REINV1200P RINV2200P REINV2200P

DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro

Differential Pressure Transmitter

Inverter User Manual

Compressor Duty Motor - 1 HP. Model 40132

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:

Cordless Rechargeable Saw Instructions for Use

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual

INSTRUCTION MANUAL ANGLE GRINDER PT W

PI1500X Power Inverter User s Manual

User Manual of Battery Charger

Switching DC Power Supply

Operating conditions of VRLA batteries in HVCBS and LVDBS Systems

System 3 ZB1PS Device Chassis. Operator s Manual

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

Submersible Pump Instructions. Safety Instructions

3.3kWh Battery Pack Specification 3.3

AUTOMOTIVE POWER INVERTERS INSTRUCTIONS. Item #31463, #31464, #31465

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

INSTRUCTION & INSTALLATION

M Series External Battery Frame. User Guide

Breezair TBA 550 Installation Manual

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

c-go 24V/6A 24V/8A 24V/12A

GARDEN HOSE UTILITY PUMP

Power Inverter 400 MW Owner s Manual

XCM12 Mini-Centrifuge

Light Source User Guide

DIGI-CUT 40PFC MV. Part No. 9030H OPERATOR S MANUAL

Installation and Service Manual for RV33, RV332, RV75, RV752, RV100, RV1002

Sconce INSTALLATION INSTRUCTIONS P C

FJC, Inc. Part # V BATTERY Charger/Maintainer INSTRUCTION MANUAL SAFETY WARNINGS AND PRECAUTION

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Operation Manual. H6000 Series

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Installing a Cool On-Column Inlet

LED Twister II. User manual UK Version 1.0

ATM Lighting sp. z o.o

MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd.

INSTRUCTION MANUAL YOKOHAMA QUICK CHARGER WITH LCD DISPLAY. Safety

DC Master 24/ A

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

6L Oil-less Air Compressor 53103

Motorized Two-Way Ball Valve with Screwed-End Connection

USER S MANUAL. TwinFresh R-50 SINGLE-ROOM REVERSIBLE VENTILATOR

LH16E - LH16EN Angle mini-polishers OPERATING AND MAINTENANCE INSTRUCTIONS

SMC BATTERY CHARGER USER S MANUAL SMC USER S MANUAL

1-50 KVA SINGLE-PHASE SERVO REGULATOR INSTRUCTIONS FOR USE SERVO SINGLE-PHASE VOLTAGE REGULATOR

SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E RAS-M18PKVP-E RAS-3M26UAV-E. FILE No. A

Powerware Vdc Extended Battery Cabinet User s Guide.

Portable Pack USER MANUAL

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.

1100W PORTABLE GENERATOR

USER MANUAL MPS 1-5KW SERIES

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

ROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)

8300 Series Installation Guidelines

SSPF SO73-SO84A SSCA. Electric orbital sanders with dust extraction OPERATING AND MAINTENANCE INSTRUCTIONS

PureSine 150/300 Pure Sine Wave Inverter User s Manual

MP V 8A Electronic Smart Charger. Instruction and Information Manual

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTRUCTION MANUAL FOR LINEAR COMPRESSORS

ACTIVAL Two-way Ball Valve with Threaded-end Connection

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

SCC-MPPT Solar Charge Controller

Operating Instructions

Relay Retrofit Program Cutting Tool Safety Guide

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

1/2 HP SUMP PUMP OWNER'S MANUAL

Operating instructions EWB 200

Transcription:

P AT. PEND. HOT Planika N E W S E N S O F FI R E FUEL ERROR READY ECO ST ART ST OP INSTALLATION MANUAL PrimeFire#2 PF-0757-0000-000 A B C D x 1 x 1 x 1 x 1 H2 H H1 [mm] [ ] H 139 5 1 /2 L1 D1 H1 137 5 3 /8 H2 2 1 /16 L 700 27 9 /16 L1 674 26 9 /16 D L2 500 19 11 /16 L3 100 3 15 /16 D 245 9 5 /8 L3 L2 L L3 D1 219 8 5 /8 Manufactured by: Planika Sp. z o.o. ul. Bydgoska 38 86-061 Brzoza Poland Copyright 2015 Planika Sp. z o.o. www.planikafires.com i0826#01 30.04.2015 1

General information Do not install the device in areas with a capacity of less than 58 m 3 / 2.049 ft 3 (22 m 2 / 240 ft 2 with a height of 2.6 m / 8.53 ft). Net weight: 11 kg. While installing the device according to the instruction manual local and national guidelines are to be observed. Place the device on a levelled surface. The cavity for the fireplace has to be designed with the use of a spirit level. It is not permitted to use the fireplace that is not placed in a housing. The cavity has to be designed according to the guidelines and dimensions in the instruction manual. If the cavity has different dimensions it has to be adjusted in such a way that it complies with the guidelines stated in the installation manual. Do not obstruct the ventilation slots and/or ventilators. Do not place any decorative elements on the device. Do not install the device in areas of large drafts of air, near fans, vents, etc. Do not place in areas where there might be a potentially explosive atmosphere of paint vapours, industrial dusts, etc. No flammable items should be placed in direct contact and within a radius of 1 m / 3.28 ft around the device. Do not place near curtains, net curtains, etc. Do not expose the device to weather conditions. The product is for internal use only. Do not expose the device to meteorological conditions. The device is for indoor use only. Do not place the device in close proximity to sources of humidity. It is obligatory to have a carbon-dioxide (CO 2) or dry chemical extinguisher placed nearby the device. Installation of the device must provide an easy removal of the device for service. The room in which the device will be installed must have efficient ventilation to ensure air exchange in the room at least once per hour. Do not start the device before a complete and proper installation. Do not fill the fuel container before placing the product into its final position. Copyright 2015 Planika Sp. z o.o. www.planikafires.com i0826#01 30.04.2015 2

INSTALLATION ATTENTION! If you have purchased the original steel casing for the device, please follow the instruction manual provided for the casing and skip the procedure described below. - Place the device in a housing that is closely connected to the construction of the building. - The elements of construction over the furnace must be made of non-flammable materials. - Recess, what will be done below the grate fireplace must be sealed. Non-flammable materials Due to fire safety, under no circumstances there cannot be any flammable materials within 1 m radius from the fireplace. Also, Planika does not recommend to place any heat sensitive materials or devices as it can significantly limit the materials properties and lifetime. Planika will not bear any responsibility for the damage of the heat sensitive materials or devices being installed above the fireplace. Non-flammable materials min 1000 mm min 39 3 8 " min 1500 mm min 59 1 16 " 50 mm 1 15 16 " 50 mm 1 15 16 " min 1000 mm min 39 3 8 " min 1000 mm min 39 3 8 " - supply the housing with a loose cable min. 3x0,75 mm 2, with power supply 230 V, 50 Hz, to connect the device to the mains. - if there is going to be a cover over the furnace, it must be made of non-flammable materials and the minimum distance from the furnace must be kept - not less than 35 cm/ 13 ¾ in. - it is not allowed to use a device not covered with a housing. Copyright 2015 Planika Sp. z o.o. www.planikafires.com i0826#01 30.04.2015 3

How to self-make the housing for the device. 2 mm 1 16 " 700 mm / 27 9 16 " min 150 mm min 5 7 8 " 680 mm / 26 3 4 " Make a cavity for the insert following the diagram below. Making the cavity make sure that the plane on which you are going to set the furnace inset is well levelled, as later it will not be possible to level the insert. A-A min 710 mm / min 27 15 16 " A min 255 mm min 10 1 16 " min 350 mm min 13 3 4 " B min 12 mm min 13 mm min 150 mm min 5 7 8 " 680 mm / 26 3 4 " 230 mm 9 1 16 " B-B 680 mm 26 3 4 " min 710 mm min 27 15 16 " 230 mm 9 1 16 " min 12 mm min 13 mm min 255 min 10 1 16 " Copyright 2015 Planika Sp. z o.o. www.planikafires.com i0826#01 30.04.2015 4

The difference in level between the ends of the furnace must not exceed 2 mm. Poor levelling may cause abnormal operation of the device and, in extreme cases, it can cause leaks of the Fanola liquid and the danger of fire. Level the plane of the cavity. The level deviation must not exceed 2 mm ( 1 16"). Then connect the supplied cable with a connection block at the end of the cord. Note that connection to the mains must be made by a qualified electrician. The furnace assembly "A" is connected to mains now. Set it in the prepared cavity. Connection to the mains must be made by a qualified electrician Copyright 2015 Planika Sp. z o.o. www.planikafires.com i0826#01 30.04.2015 5

ATTENTION!!! Make sure that the product has been correctly installed and read the attached instruction manual. You are not allowed to fill the fuel tank and start the device before having read the instruction manual. If in the future it is necessary to take the device out of the housing, wait until the fuel has burned-up completely and the display shows the device out of the housing. FUEL, disconnect the power supply and take Keep this instruction manual throughout the lifetime of the device. Copyright 2015 Planika Sp. z o.o. www.planikafires.com i0826#01 30.04.2015 6