DATASHEET 63JMP/20/4/3/32

Similar documents
CASED AXIAL BIFURCATED SERIES 33

Section 4 e c tio - P lat F a n s


ExpressBuild STANDARD FAN RANGE

Section 4. Axial Fans - Section 4


MAXFAN COMPAC » OFFERING HIGH PERFORMANCE, ROBUST DESIGN AND FLEXIBLE CONTROL AIR COMFORT FIRE SAFETY AIR MOVEMENT

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

JM Aerofoil Multi-Stage 50 Hz


ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION

Wide performance ranges are obtained by using three impeller designs to suit all types of applications.

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315

CASED & PLATE AXIAL - ACCESSORIES

Axial fans. What s more, non-stock models are normally available within two weeks.

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Bifurcated Case Axial Fans (BIFA)

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

CGT Series Adjustable Pitch Fans

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

CGT Series Adjustable Pitch Fans

JM Aerofoil Bifurcated Fans

SLCX ATEX LONG CASED AXIAL FLOW FAN PLEASE CONTACT AERAULIQA DIRECLTY FOR A SPECIFIC FAN SELECTION ACCESSORIES APPLICATION FEATURES & BENEFITS

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

Max. airflow m 3 /s Diam. min. Diam. max

ROOFMASTER STEF-HT ROOF FAN

Short casing. Long casing (L version) Commercial premises

Hison Axial Flow Fans

BIFLOW SB CON Product Brochure

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

Hison Axial Flow Fans

COMPACT Series type HCFB / HCFT (Plastic impellers)

Roof Units. Specification. Construction. Performance. Impellers. Size range. Ancillary Equipment

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Vent-Axia Sabre Sickle Roof Fans (VSR)

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

TUBE & BOX FAN - ACCESSORIES

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

JM Aerofoil Bifurcated 50Hz

TGT Series Adjustable Pitch Fans

BIFURCATED AXIAL FANS

Plate mounted axial flow fans HXBR / HXTR Series

CYLINDRICAL CASED AXIAL FLOW FANS

M1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT

TGT Series Adjustable Pitch Fans

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

AC Commercial Fans Edition. ErP ready

Sabre Plate Mounted Sickle Fans (VSP)

REVOLUTION SLCX Product Brochure

SECTION AXIAL HVAC FANS

Performance. Sound Levels. Impellers. Motors. Accessories

Twin City Fan & Blower

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

ROOFMASTER STEF-ATEX ROOF FAN

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

MAJAX-2 GENERAL SPECIFICATION

Transformer Oil Cooling Solutions

Size and Configurations

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

NEW GENERATION SERIES

ROOFMASTER STEF-HT ROOF FAN

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Turbo Exhausters and Blowers

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

AXIAL FLOW CABINET FAN CGT Series

Medium Pressure Centrifugal Fans

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

ELECTRIC MOTORS. Selection. Starting torque and nominal torque

CHMT Series, F Rated Fans

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

TURBOFLOW TF Contra Rotating Axial Flow Fan

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

42HS Fan Coil Unit (High Static Pressure)

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

ROOFMASTER STEF ROOF FAN

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

ARW DRY COOLERS AXIAL FANS VERSION, MEDIUM AND HIGH CAPACITY. CAPACITY FROM 20 TO 775 kw ARW DRY COOLERS

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

1SV (e-sv) 60 Hz 3500 RPM

FAN & BLOWER CENTRIFUGAL FANS

SERIES COOLING TOWER SINGLE-CELL UP TO 1500HRT COOLING CAPACITY

Energy-saving motors (ESM)

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

Transcription:

62 ATE HMIDITY FAS SESOR JM STB-02 ATE FA DATASHEET RODCT FACTS Air flow up to 8.17 m 3 /s Static pressures up to 260 a Motor protection I55 Speed controllable Supplied fully assembled Full range of accessories Speed controllable EECTRICA SY 220-240V/50Hz/1f & 380-420V/50Hz/3f TEMRATRE RAGE -40ºC to 50ºC as standard. Suitable for 70 C at full speed. SIES 315, 355, 400, 450, 500, 560, 630, 710 & 1000 mm ATE lates manufactured from mild steel with powder coat finish, fans are supplied as standard with motor side guard. S All motors are totally enclosed airstream rated class F insulation. Constructed from aluminium or cast iron as standard with special T slot, or pad mounted fixings Suitable for horizontal through to vertical shaft operation. Supplied I55 with removable drain plugs. These motors are suitable for inverter speed control down to 20% of full speed. IMERS RODCT CODE 63JM/20/4/3/32 63 - denotes the Fan impeller diameter in centimetres JM - denotes late Fan type 20 - denotes impeller hub diameter in centimetres 4 - denotes a nominal 4 ole speed 3 - denotes the number of blades 32 - denotes the itch Angle for the required duty ACCESSORIES (ages 230-237) COTROERS (ages 249-297) A unique high efficiency aerofoil section blade. Woods impellers are all high pressure die cast to offer thin aerofoil sections for low generation of noise. Every cast aluminium component is X-ray examined using Real Time Radiography inspection prior to assembly. The maximum pitch angles shown allow for speed control by frequency inverter. ouvre Shutters Imepller side Guard Controls Transformer Controls Inverter Controls Electronic

63 JM RFORMACE AD EECTRICA DATA 220-240V/50H/1f RFORMACE CHART 300 200 Static ressure (a) 100 2 35JM/16/4/5/22 3 40JM/16/4/5/29 4 45JM/16/4/5/24 5 50JM/20/4/6/24 6 56JM/20/4/6/24 1 31JM/16/4/5/30 7 63JM/20/4/3/24 0 0 5000 10000 15000 0 0.5 1 1.5 2 2.5 3 3.5 4 Volume Flow m 3 /h m 3 /s RFORMACE TABE roduct m 3 /s at a (Static) 0 50 100 150 200 250 1 31JM/16/4/5/30 0.54 0.46 2 35JM/16/4/5/22 0.63 0.54 3 40JM/16/4/5/29 1.27 1.15 0.99 0.77 4 45JM/16/4/5/24 1.48 1.34 1.16 0.87 5 50JM/20/4/6/24 1.91 1.76 1.59 1.36 1.03 6 56JM/20/4/6/24 2.93 2.77 2.57 2.33 2 1.55 7 63JM/20/4/3/24 3.86 3.54 3.19 2.79 2.3 RODCT AD EECTRICA DETAIS roduct roduct umber itch Angle ( ) Speed rev/min Motor (kw) Full oad Starting Wiring Diagram (CD) Speed Controller Electronic Transformer Inlet Sound evels Efficiency Target Grade 1 31JM/16/4/5/30 E315412 30 1430 BT5 0.075 0.54 1.45 CD3038 ME1.1 TEID 1 42 Er Exempt 2 35JM/16/4/5/22 E355412 22 1430 BT5 0.075 0.54 1.45 CD3038 ME1.1 TEID 1 43 Er Exempt 3 40JM/16/4/5/29 E405415 29 1420 BT5 0.16 1.12 2.15 CD3038 ME1.3 TEID 1.5 49 30.4 27.0 40 4 45JM/16/4/5/24 E455410 24 1360 BT9 0.32 2.2 5.0 CD3038 ME1.3 TEID 2.2 49 35.3 31.0 44 5 50JM/20/4/6/24 E505415 24 1360 CT9 0.39 2.9 5.4 CD3038 ME1.3 TEID 3.5 53 29.4 28.7 40 6 56JM/20/4/6/24 E565411 24 1400 CT9 0.97 6.9 13.5 CD3037 ME1.6 TEID 7.5 55 39.7 33.7 46 7 63JM/20/4/3/24 E635411 24 1400 CT9 0.97 6.9 13.5 CD3037 ME1.6 TEID 7.5 57 43.5 33.8 49 For Er efficiency ratings and grades please refer to our Fan Selector for more information. Sound pressure levels quoted are at the inlet, and are average dba at 3m distance over a sphere at the mid point at the highest angle given, under free field conditions. These are presented for comparative purposes only. For speed controllers please see pages 250-297.

DECO HA SEMCO FAT WOODS DEBAG IOXAIR 64 JM RFORMACE AD EECTRICA DATA 380-420V/50H/3f RFORMACE CHART 300 200 Static r essure (a) 3 56JM/20/4/6/32 100 1 45JM/16/4/5/32 2 50JM/20/4/6/32 4 63JM/20/4/3/32 6 5 71JM/20/6/6/24 100JM/20/8/6/24 0 0 5000 10000 15000 20000 25000 30000 0 1 2 3 4 5 6 7 8 Volume Flow m 3 /h m 3 /s RFORMACE TABE roduct m 3 /s at a (Static) 0 50 100 150 200 250 1 45JM/16/4/5/32 1.8 1.62 1.39 1.08 2 50JM/20/4/6/32 2.38 2.2 2 1.74 1.4 3 56JM/20/4/6/32 3.58 3.35 3.09 2.79 2.43 1.97 4 63JM/20/4/3/32 4.65 4.33 3.96 3.53 2.99 5 71JM/20/6/6/24 3.89 3.54 3.06 2.3 6 100JM/25/8/6/24 8.17 7.4 6.45 5.25 RODCT AD EECTRICA DETAIS roduct roduct umber itch Angle ( ) Speed rev/min Motor (kw) Full oad Starting Wiring Diagram (CD) Speed Controller Electronic Transformer Inverter Inlet Sound evels Efficiency Target Grade 1 45JM/16/4/5/32 E455430 32 1360 BT9 0.39 1.26 3.9 CD2417 /A TDID 2.5A IDDXF54-2.2 52 31.9 31.8 40 2 50JM/20/4/6/32 E505430 32 1360 CT9 0.83 2.3 8.6 CD2417 /A TDID 2.5A IDDXF54-3.7 56 34.6 33.1 41 3 56JM/20/4/6/32 E565430 32 1400 90S (IE2) 1.32 2.84 15.6 CD2416 /A /A IDDXF54-3.7 60 39.7 34.3 45 4 63JM/20/4/3/32 E635430 32 1400 90S (IE2) 1.32 2.84 15.6 CD2416 /A /A IDDXF54-3.7 59 41.4 34.7 46 5 71JM/20/6/6/24 E715630 24 900 80 (IE2) 0.66 1.64 6.07 CD2416 /A /A IDDXF54-2.2 53 39.8 33.3 46 6 100JM/25/8/6/24 E135630 24 695 112M (IE2) 1.80 4.51 19.39 CD2417 /A /A IDDXF54-5.3 61 40.8 35.5 45 For Er efficiency ratings and grades please refer to our Fan Selector for more information. Sound pressure levels quoted are at the inlet, and are average dba at 3m distance over a sphere at the mid point at the highest angle given, under free field conditions. These are presented for comparative purposes only. For speed controllers please see pages 250-297. roducts in bold are available from our Distributors on next day delivery, if ordered by 4pm. lease call to confirm availability on 01206 222 580.

65 DRAWIG - JM ATE G AROX F E 10 GARDS SIED CAACITOR (1 HASE OY) AØ ISIDE AIRFOW FORM A OY C CRS D CRS B SQ 4 SOTS 12 WIDE Aluminium frames, plastic shutters. Shutters must be separated from the fan mounting plane by the following minimum distances: p to 500 mm Ø 150 mm 560 to 710 mm Ø 200 mm 800, 1000 mm Ø 275 mm ote; that under some combinations of fan speed and wind the shutters vanes may become unstable. This is more likely to occur at reduced fan speed. Motor Range A B C D E F G Weight (kg) 31JM/16/4/5/40 1420 315 425 375 400 100 263 18 10 35JM/16/4/5/34 1440 355 475 425 450 100 256 20 11 40JM/16/4/5/40 1440 400 520 470 495 100 295 22 14 45JM/16/4/5/40 1440 450 585 535 560 100 268 24 17 50JM/16/4/5/30 1440 500 650 600 625 110 259 26 18 56JM/16/4/5/30 1440 560 715 665 690 110 299 28 23 63JM/16/4/3/24 1420 630 780 735 755 110 306 23 26 71JM/20/6/6/24 900 710 875 830 850 110 270 23 32 100JM/25/8/6/24 695 1000 1170 1110-107 395-101 All dimensions in mm.

66 WIRIG DIAGRAMS - JM ATE CD2416 THREE HASE JM STAR COECTIO 1 V1 W1 ICOMIG EADS TO MATCH BOC ETTERIG. 1 V1 W1 V2 2 W2 V W ADDITIOA CIRCITS WHE FITTED: THERMA ROTECTIO SS - THERMISTOR - THERMOSTAT 1 2 3 THREE HASE SY TO REVERSE ROTATIO SWA AY 2 ICOMIG HASES EARTH TO BODY CASE CD2417 THREE HASE JM DETA COECTIO ICOMIG EADS TO MATCH BOC ETTERIG. 1 V1 W1 V2 2 W2 V W ADDITIOA CIRCITS WHE FITTED: THERMA ROTECTIO SS - THERMISTOR - THERMOSTAT 1 2 3 THREE HASE SY TO REVERSE ROTATIO SWA AY 2 ICOMIG HASES FOR SE O STAR/DETA AC REMOVE IS EARTH TO BODY CASE

67 WIRIG DIAGRAMS - JM ATE CD3038-315-500 JM 1 HASE (WITHOT AD WITH ME SED COTROER) SIGE HASE FA WITH ITERA CAACITOR AD OVERHEAT ROTECTIO OVERHEAT ROTECTIO A OVERHEAT ROTECTIO FA BOC CAACITOR A B FA BOC CAACITOR A M.E SED COTROER 3-WIRE COTRO (IVE) (VARIABE ETRA) (F ETRA) 230V/50Hz SIGE HASE ROTECTED SY FA COECTED TO SY (F SED) FA COECTED TO SED COTROER (VARIABE SED) 230V/50Hz SIGE HASE ROTECTED SY CD3037-560-630 JM 1 HASE (WITHOT AD WITH ME SED COTROER) For JM single phase transformer speed controller wiring diagrams please refer to page 47 OVERHEAT ROTECTIO OVERHEAT ROTECTIO FA BOC CAACITOR B FA BOC CAACITOR A M.E SED COTROER 3-WIRE COTRO (IVE) (VARIABE ETRA) (F ETRA) 230V/50Hz SIGE HASE ROTECTED SY FA COECTED TO SY (F SED) FOR OVER HEAT ROTECTIO COECT THE THERMA CT OT S '' TO A RE-SETTABE DEVICE WHE FA EXCEEDS 6.3A (IF AICABE REMOVE I A AD COECT IVE WIRE ''FROM THE SED COTROER TO '' O THE FA BOC). 230V/50Hz SIGE HASE ROTECTED SY FOR OVER HEAT ROTECTIO COECT THE THERMA CT OT S '' TO A RE-SETTABE DEVICE WHE FA EXCEEDS 6.3A (IF AICABE REMOVE I A AD COECT IVE WIRE ''FROM THE SED COTROER TO '' O THE FA BOC). FA COECTED TO SED COTROER (VARIABE SED)