WEK. Wasserentkeimung METASYS WEK Light Gerätedokument Einbau, Betrieb und Wartung

Similar documents
SANITARY COMPRESSED AIR COMPRESSORS. with membrane dryer with thermal protection with hour meter

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

VANGUARD A EZ INSTALL OPERATOR S MANUAL

original operating manual Operating manual Translation of the Item-No.: ,

1416 Cabinet Unit. Installation Operation Maintenance Troubleshooting Version Dec/17

UVR-Mi UV-air flow Cleaner - Recirculator

HEINE NT4 MED V

Electronic tank monitoring device (complete kit) - for battery tanks - incl. overfill safety - after TRwS 791(-2) with clearance display

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

Instructions For Use VATEA. Endodontic Irrigation Device

Operating Instructions. International English. CCS Dust Extractor

Documentation. RM-BV4 Micro DP. Filter control

USER MANUAL FOR AUTOMATIC A/C CHARGING STATIONS

Oil-free piston compressors KK and piston vacuum pumps KV

Technical Manual. Installation Instructions Safety Notices Programming Operation

Direct Coupled Damper Actuator Model MY9050A1001

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

Solenoid Operator 0516 / 1216

Katalysator Nr /

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Solenoid Operator 0513 / 1213

Direct Coupled Damper Actuator Model MY6050A1001

Safety drying oven with expended temperature range

Installation Operation Maintenance Troubleshooting Version 1, Oct/09. Palm Beach

Fluid level checks ENGINE OIL CHECK

Xenon Fiberoptic Lightsource

KESSEL-Grease Separator Under sink

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

Bendix BlindSpotter Side Object Detection System. Installation Guide

Cascade Master Series

Application cup for OptiFlex 2 GM03 manual powder gun

Instructions for the BCEA Rotary heat exchanger

CRS1, CRS2 and CRS3. For additional information please call our. PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard, LaVergne, TN

KSZ 10B Current Probe Calibrator. Instruction Manual

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

- Wiring Brochure Zone Manager 335

MODEL 905V OPERATING INSTRUCTIONS

- Wiring Brochure Zone Manager 336

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

Safety drying ovens with expanded temperature range

OPERATION INSTRUCTIONS GFA-W-150\300\500\1000

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

BlueSwan Pipette Controller

400 Watt Backup Power System Owner s Manual

User Manual Rittal PMC UPS 6kVA

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Operating instruction and technical description

PNEUMATIC PUMP Series

KSZ 100B Current Probe Calibrator. Instruction Manual

Perfect Liquid Handling PRECISE RESULTS WITH INNOVATIVE TECHNOLOGY

SOLAR CHARGE CONTROLLER N 2010 IN 2011/ N 2012/ N 2014

EASY CHARGE Waterproof portable Battery Charger

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Safety drying ovens. Advantages: Areas of application: FDL series 115

INDEX. - DESCRIPTIONS OF THE APPLIANCE Page 3. - TECHNICAL DATA AND ACCESSORIES Page 4. - OPERATING METHOD Page 5. - FUSES REPLACEMENT Page 11

ENGLISH SAFETY INSTRUCTIONS. Recommendations for safe operation. Operator safety. General warnings

HBLT-Wire LEVEL SENSOR For analogue measurements of NH3 and HFC in refrigeration systems

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Operating instructions and spare parts list. LM01 Level sensor. Translation of the original operating instructions

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04)

Thermal Circuit Breaker 3120-F...

BATTERY SAVER LOW RIPPLE HO

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Multi-Mover Charger for model L25

MOOG Medical Devices Group Curlin 6000 Series Ambulatory Infusion Pump PATIENT GUIDE

SOLAR CHARGE CONTROLLER

Vehicle Security System

Differential Pressure Transmitter

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Operating Instructions K Always on the safe side.

Operating manual POWER TINY USA. a Look Solutions 1 product

Automatic Burnout Furnaces 115 to 230-volt Models OPERATOR S MANUAL

ZB0050 / ZB0051 ZB0070 / ZB0071

OWNER S MANUAL Please read this manual before operating your power supply

OPERATING MANUAL 18V Ni-Cd Battery Pack

Operating Instructions

Operating Instructions type Always on the safe side.

Operating manual UPS - System

Wilo-Control SC-Fire Jockey

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

Switches- and Indicators

Instruction Manual. Ex-Time 40 / 50

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Intelligent Electronic Safe

WARRANTY...1 NOTICE INTRODUCTION USE...8

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Instrucciones de instalación y funcionamiento Installation and operating instructions

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

Engine oil. Introduction. Warning and indicator lights WARNING

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Transcription:

Wasserentkeimung METASYS WEK Light Gerätedokument Einbau, Betrieb und Wartung Water Decontamination System METASYS WEK Light Equipment Logbook Assembly, operation and maintenance Système de decontamination de l eau METASYS WEK Light Livret d appareil Installation, fonctionnement et entretien Decontaminatore idrico METASYS WEK Light Verbale d installazione Montaggio, funzionamento e manutenzione WEK L i g h t

Index Explanation of the pictograms 1. Index The header on each page defines the user group particular information is aimed at. Chapter Page 1. Index 2 2. Explanation of the pictograms 2 3. General information 3 4. Application 4 5. Construction 4 6. Explanation of the type plate 5 7. Technical data 5 8. Functional description 6 9. Installation options 7 10. Hose connections 8 11. Electrical connections 8 12. Description of the control unit 9 13. Disinfectant 10 14. Changing the GRE&CLEAN WK bottle 10 15. Intensive decontamination 11 16. Inspection of GRE&CLEAN WK 11 17. Servicing 11 2. Explanation of the pictograms i Information Caution! General warning sign Refer to instruction manual/booklet 2

General information 3. General information The safety, reliability and performance of the appliance is only guaranteed by METASYS if the following instructions are observed: Assembly, alterations or repairs may exclusively be carried out by authorized service personnel in compliance with Standard 60601-1 (International Standard for Medical Electrical Apparatus, in particular Part 1: General Rules for Safety). The electrical installation must comply with the regulations of the IEC (International Commission for Electrical Engineering). The apparatus must exclusively be used in conformity with the instructions for installation, operation and maintenance. Only original parts may be used for repairs or replacements. All the guidelines provided by the manufacturer on the correct use of the water decontamination system WEK Light must be followed. After commissioning, complete the proof of installation at the front page of this manual and send this to METASYS in order to define the warranty period. All inspection and service work must be entered into the device documentation at the first pages of this manual When requested by an authorized engineer, METASYS agrees to make all documents available for the use of technically qualified service personnel. METASYS accepts no responsibility for damages caused due to external factors, such as wrong installation, improper use of the apparatus or unauthorized technical intervention. Users must study equipment and assure themselves of its good condition before every use. The equipment is not suitable for use in explosive or combustible environment. 3

Application Construction 4. Application 1 The METASYS WEK Light water decontamination system is a system which enables decontamination of the water supply and pipes using the special disinfectant GRE&CLEAN WK. The WEK Light supplies the water-bearing apparatuses and instruments (syringe, turbine, water glass filler, etc.) of a dental practice with decontaminated water by using the respective decontamination solution. The WEK Light water decontamination system supplies all consumers of the dental unit. Their water consumption averages at: syringe: 100-130 ml / minute turbine, handpiece and angle piece: 50-70 ml / minute water glass: 150 ml / glassfull 5. Construction To ensure optimal user and service friendliness, the WEK Light water decontamination system consists of several modules: 1 Module 1 Electronic control system 2 4 3 5 6 2 Module 2 Mixing container; here, water is mixed with the disinfectant. 3 Module 3 Double membrane pump and membrane break sensor 4 Module 4 Magnetic block: This controls the addition of disinfectant via the double membrane pump 5 Module 5 Disinfectant sensor 6 Module 6 Flow meter 7 Module 7 Water intake filter, 80 µm, pressure regulator 8 Module 8 Housing (optional); consisting of housing, mounting plate, main water tap, transformer and main tap 4 7 8

376 mm 252 mm Explanation of the type plate Technical data 6. Explanation of the type plate 9 See illustration The type plate is attached to the top of the auxiliary housing of the floor model, and on the mounting plate of the built-in unit. 9.1 Equipment type name 9.1 9.2 9.3 9.4 9.5 9.8 9.2 Mains supply data 9.6 Built-in unit (UN = 24 V AC) Floor model (UN = 230 V AC) 9.3 Maximum power consumption 9.4 Maximum water flow rate 9.5 Permitted water pressure 9 105 mm 183 mm 160 mm 9.7 9.6 Serial number 125 mm 9.7 Address of manufacturer 9.8 CE conformity mark 220 mm 7. Technical data Versions floor model / built-in unit Voltage 230 V AC (floor model)/ 24 V AC (built-in unit) Frequency Maximum power consumption 50/60 Hz 30 ma (floor model)/ 200 ma (built-in unit) 10 Permitted water pressure 1-6 bar Permitted air pressure 4-8 bar Operating pressure (water) inlet pressure dependent / 2,5 bar Operating pressure (air) 3.5 bar Maximum water flow rate Disinfectant 6 l/min GRE&CLEAN WK hydrogen peroxide, 2% solution 335 mm Mixing ratio 1:85 standard setting, 1:42 intensive decontamination Working solution 235 ppm see figure 10 and 11, dimensions (H x W x D) 335 x 265 x 160 mm (floor model) 220 x 160 x 235 mm (built-in unit incl. GRE&CLEAN WK bottle) 11 265 mm 160 mm 5

Functional description 8. Functional description compressed air supply pressure regulator pressure regulator magnetic valve flow meter water inlet filter double membrane pump magnetic valve 1 (disinfectant) disinfectant sensor GRE&CLEAN WK 1 See illustration Water coming from the water inlet is fed into the mixing container via the water inlet filter and the flow meter. The flow meter measures the water flow rate. After supplying 150 ml water, the flow meter emits an electronic pulse which in turn actuates the magnetic valve 1. The magnetic valve 1 opens and activates the compressed air operated double membrane pump, causing approx. 1.75 ml hydrogen peroxide to be withdrawn and added to the mixing container. If a water-fed consumer is activated, the decontaminated water flows from the mixing container via the pressure container to the appropriate instrument. The disinfectant GRE&CLEAN WK is sucked in. A disinfectant sensor checks the presence of the disinfection concentrate. If the GRE&CLEAN WK bottle is empty, an error message occurs. Please note that only METASYS GRE&CLEAN WK may be used, as the electrical sensors are adjusted to this product! mixing container water GRE&CLEAN WK decontaminated water compressed air to the consumers 1 6

Installation options Technicians 9. Installation options The modular design of the WEK Light water decontamination system allows the following installation options: 2 Integration into the treatment unit Direct integration of the WEK Light water decontamination system into the treatment unit is the preferred option in order to keep the water and compressed air pipes supplying the WEK Light as short as possible. Care should be taken to ensure vibration-free attachment of the unit to weight-bearing parts of the treatment unit. 3 Integration in the auxiliary housing If the direct integration of the water decontamination system into the dental treatment unit is not possible, it can be installed as a floor model with a shapely housing. The housing requires only a minimum amount of floor space and should be mounted onto the junction box of the treatment unit. The external display and a transformer are already incorporated into the housing. Main switch: It must be ensured that the power supply is connected downstream of the main instrument/ practice switch. 2 3 Please note that the transformer is still energised if the main switch of the unit is turned off! The unit has to be disconnected from the power supply with the main instrument/practice switch, before any installations or repairs are performed! 7

Hose connections Electrical connections Technicians 10. Hose connections 1 See illustration 1.3 1.4 1.2 1.1 1.1 Compressed air connection Permitted pressure at entry: 4-8 bar PUR tubing I.D. = 2.5 mm / O.D. = 4 mm 1.2 Water connection (fresh water) Permitted pressure at entry: 1-6 bar PA tubing (with KTW authorisation) I.D. = 4 mm / O.D. = 6 mm 1.3 Connection to GRE&CLEAN WK bottle PVC tubing I.D. = 2 mm / O.D. = 4 mm 1.4 Connection to the water outlet (supply of instruments) PUR tubing I.D. = 4 mm / O.D. = 6 mm 11. Electrical connections 1 METASYS WEK Light SIC1 T1,6A X1 24V~ X4 WK-54.911/02; 2018-02 V3 V4 V2 V5 valves 3 V3 X7 2 V2 X3 NE Ta CH Su ST - Bed. LEDs NE X14 0 FL PWR IC14 CH X10 X15 Ext. ser. Proc. sensors X13 9 MB2 7 8 MB1 X11 2 See illustration 2.1 Flow measuring (X14) 2.2 Disinfectant sensor (green) (X10) 2.3 External display (X3) 2.4 Air valve (black) (V2) 2.5 Valve for disinfectant solution (black) (V3) 2.6 Membrane break sensor (yellow) (X11) 2.7 Power supply plug 24 V AC (orange) (X1) The power voltage must be supplied by a transformer which meet the specifications of 60601-1 and 61558-2-6. 2.8 Main fuse MST250/T 1,6 A/UN 250 V/ ICN 35 A (replace with same type only!) 2.8 2.7 2.3 2.5 2.1 2.2 2.6 2.4 8 2

Description of the control unit 12. Description of the control unit 3.1 3.2 3.3 3 See illustration 3.1 Control light 1: Ready for use (green) 3.2 Control light 2: Error (red) 3.3 Control light 3: Disinfectant sensor (yellow) 3.4 Alarm RESET button 4 Switching on/illuminated: The green control signal 3.1 flashes The green control signal is illuminated when the WEK Light is ready for operation. 3 3.4 5 The green control signal 3.1 and the yellow signal 3.3 are illuminated, as well as sound of the alarm: Cause: Disinfectant sensor indicates that the process water is not being decontaminated! Action: Change the GRE&CLEAN WK bottle (see page 10)! If the GRE&CLEAN WK bottle cannot be changed immediately, the RESET button must be pressed to deactivate the continuous alarm. The unit remains fully functional and does not interrupt the dentist s work. However, a short signal tone still sounds periodically. In case the error had been caused by an air bubble it will be gone at the next attempt. However, no decontamination takes place until the empty chemical bottle is replaced with a full one (see page 10). 4 6 The green control signal 3.1 and the red signal 3.2 are illuminated, the alarm tone sounds: Cause: Defect of the double membrane pump Action: Check the double membrane pump and the electronic control system. Consequence: The alarm tone can be switched off by pressing the RESET button. After resolving the problem the WEK Light can only be reactivated by switching the unit off and on. 5 6 9

Disinfectant Changing the of GRE&CLEAN WK bottle 13. Disinfectant 1 See illustration 1 1.1 GRE&CLEAN WK, a 2% hydrogen peroxide solution with added silver, is used as the disinfectant. Due to their potent bactericidal and fungicidal action, hydrogen peroxide-based concentrates are particularly suitable for reducing microorganism levels in process water. The ratio of disinfection efficacy and potential risks of hydrogen peroxide are excellent, which means they present no risk to the patient. During each disinfecting cycle of the METASYS water decontamination system, a designated amount of disinfectant is added to the 150 ml of water in the mixing container. This is how the 0.0235% concentration required for broad-spectrum disinfection is prepared. Once the GRE&CLEAN WK bottle is completely empty, an error signal appears on the external display, stating that no more disinfectant can be drawn. The empty bottle needs to be disconnected from the cannula of the water decontamination device and replaced with a full one. 2.1 Please note that only GRE&CLEAN WK provides the concentration required for broad spectrum disinfection. GRE&CLEAN WK - refill set Order number 1.1 4 x 750 ml bottles 60040100-1 The GRE&CLEAN WK refill set can be ordered directly from your dental depot! Safety precautions: Keep out of the reach of children. In case of contact with eyes, rinse immediately with plenty of water. In case of contact with skin, wash immediately with plenty of water. Store GRE&CLEAN WK at room temperature (or 5 C - max. 30 C) and protected from light! Composition: water, hydrogen peroxide, silver and less than 0.1% stabilisers Please refer to the safety data sheet for further information! 14. Changing the GRE&CLEAN WK bottle 2.2 2 See illustration Remove the empty bottle from the device. Pull gently on the closure and the attached tube reaching into the bottle to remove the bottle 2.1. After having removed the screw cap of the new bottle insert the tube into the bottle and press the closure onto it 2.1. Afterwards place bottle back into the device. Ensure that tube is connected to the chemical port 2.2. 10 2

Intensive decontamination Inspection of GRE&CLEAN WK Servicing 15. Intensive decontamination 3 If required, the concentration of the chemical may be increased. The intensive decontamination can be activated by holding down the RESET button 3.4 (control signal 1 3.1 flashes) for approx. 4 sec. until the first acoustic signal is activated. While this procedure is taking place control signal 1 3.1 flashes and signal 3 3.3 is illuminated. After supplying 50 ml of water, an amount of 1.75 ml GRE&CLEAN WK is added. This is followed by 4 dosing operations amounting to 1.75 ml disinfectant being added after every 75 ml water. After a total of 300 ml of water has been processed, standard decontamination resumes. The intensive decontamination is performed for a total of 500 ml of water. Control signal 3 stops after the intensive decontamination, and a short acoustic signal is activated. The WEK Light returns to normal operation. 3 3.1 3.2 3.3 3.4 16. Inspection of GRE&CLEAN WK i Weekly inspections of the hydrogen peroxide concentration are mandatory since the WEK Light does not emit automated error signals if no disinfection of the process water is taking place. Using the GRE&CLEAN WK test strips it is possible to determine the concentration of hydrogen peroxide in the solution in only 45 seconds. 4.1 4.2 GRE&CLEAN WK test strips Order numbers 5 pcs / pkg 40050502 25 pcs / pkg (half-yearly requirement) 40050503 50 pcs / pkg (yearly requirement) 40050504 4.3 17. Servicing 4 4 Every 2 years a service must be performed using the WEK Light service kit (order no: 50050126). The service includes changing the magnetic valve block 4.1, replacing the prefilter cartridge 4.2, as well as 1 bottle of GRE&CLEAN WK 4.3 and 5 GRE&CLEAN WK test strips. 11

METASYS... makes the difference! Visit us at: METASYS Medizintechnik GmbH Florianistraße 3, 6063 Rum bei Innsbruck, Austria 1 +43 512 205420 5 +43 512 205420 7 www.metasys.com info@metasys.com GERMANY +49 8823 938 44 33 info@metasys.com FRANCE +33 4 37 90 22 15 info@metasys.fr ITALY +39 045 981 4477 desitalia@metasys.com 2018-02 ZK-55.078/02 70100039 Druck- und Satzfehler vorbehalten! / Subject to printing and setting errors!