D330 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Similar documents
V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Optional control panel POWER. Voltage

J80UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J200UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K28H GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

X1100C GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE

V700C2. Optional Control Panel POWER. Voltage. DIMENSIONS COMPACT VERSION 24 V charge alternator and starter

KV550C2. Optional control panel POWER

V275C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K12. Optional Control Panel POWER K12

X800 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Optional Control Panel POWER

T1400. Standard Control Panel POWER. Voltage. kw e 415/24 400/23 380/22

J220K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

T16K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J60U GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K20UM POWER 240 MONO-BI

KV550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KK44 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KV500C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION. Soundproof version with CE directive (CN09 option) Type soundproofing

KM44. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel POWER

KM33. Frequency (Hz) Voltage (V) Standard control Panel Optional control panel Optional control Panel POWER

J165K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KH275. Frequency (Hz) Optional control panel POWER. Voltage

KX1100. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

J66K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K17M POWER 240 MONO 230 MONO 220 MONO

KV550C2. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

K26M POWER 240 MONO 230 MONO 220 MONO

KV500UC2. Frequency (Hz) Voltage (V) Standard Control Panel Optional control panel Optional control panel Optional control panel POWER

V550C2 GENERAL CHARACTERISTICS POWERS DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

ENGINE CHARACTERISTICS

KD165. Engine type Alternator type Performance class. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel

KM2500. Engine type Alternator type Performance class

Engine type Alternator type Canopy Type GENERAL CHARACTERISTICS

Engine type Alternator type Canopy Type GENERAL CHARACTERISTICS

GZ40 POWER. Fuel System 50 Hz:

GZ25 POWER. Fuel System 50 Hz:

GZ50 POWER. Fuel System 50 Hz:

Type Dimensions Weight Tank Length: 6400mm 8709kg [19200lbs] [252in] Net 930 L 10000kg [22046lbs] Heigth: 2721mm Gross [107in]

Type Dimensions Weight Tank Length: 6400mm 7836kg [17275lbs] [252in] Net 930 L 9020kg [19886lbs] Heigth: 2721mm Gross [107in]

TERM OF USE Standard reference conditions ESP/PRP 27 C /40 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

TERM OF USE Standard reference conditions ESP/PRP 25 C /25 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

Engine JOHN DEERE, 4045HFS83, U.S. EPA Tier 3 Alternator LEROY SOMER, LSA442VS45 <Debut> 100KW GENERATOR

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

ENGINE DATA. 205L/s [434cfm] 565 C [1049 F] 750mm CE [30in. WG

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

USP&E Cummins Series Diesel Generator Set

USP&E Cummins Series Diesel Generator Set

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

USP&ECummins Series Diesel Generator Set

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

USP&E Cummins Series Diesel Generator Set

USP&E Cummins Series Diesel Generator Set

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Transcription:

Engine ref. Alternator ref. Performance class P126TI-II AT02260T G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Standard Control Panel APM303 Optional control panel TELYS Optional Control Panel APM802 POWER Voltage ESP PRP kwe kva kwe kva Standby Amps 415/240 260 325 236 295 452 400/230 264 330 240 300 476 380/220 264 330 240 300 501 DESCRIPTIVE Electronic governor Mechanically welded chassis with antivibration suspension Main line circuit breaker Radiator for wiring temperature of 48/50 C max with mechanical fan Protective grille for fan and rotating parts (CE option) 9 db(a) silencer supplied separately Charger DC starting battery with electrolyte 24 V charge alternator and starter Delivered with oil and coolant -30 C Manual for use and installation POWER DEFINITION PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed. TERMS OF USE According to the standard, the nominal power assigned by the genset is given for 25 C Air Intlet Temperature, of a barometric pressure of 100 kpa (100 m A.S.L), and 30 % relative humidity. For particular conditions in your installation, refer to the derating table. ASSOCIATED UNCERTAINLY For the generating sets used indoor, where the acoustic pressure levels depends on the installation conditions, it is not possible to specify the ambient noise level in the exploitation and maintenance instructions. You will also find in our exploitation and maintenance instructions a warning concerning the air noise dangers and the need to implement appropriated preventive measures. DIMENSIONS COMPACT VERSION Length (mm) 3160 Width (mm) 1340 Height (mm) 1592 Dry weight (kg) 2570 Tank capacity (L) 470 DIMENSIONS SOUNDPROOFED VERSION Commercial reference of the enclosure M228 Length (mm) 4475 Width (mm) 1410 Height (mm) 2430 Dry weight (kg) 3670 Tank capacity (L) 470 Acoustic pressure level @1m in db(a) 81 Sound power level guaranteed (Lwa) 101 Acoustic pressure level @7m in db(a) 71

ENGINE CHARACTERISTICS GENERAL ENGINE DATA Engine model Engine ref. Air inlet Cylinders arrangement DOOSAN P126TI-II Turbo L EXHAUST Exhaust gas temperature ( C) 590 Exhaust gas flow (L/s) 790 Max. exhaust back pressure (mm EC) 600 Number of cylinders 6 Displacement (C.I.) 11.05 Air coolant Air/Air DC Bore (mm) x Stroke (mm) 123 x 155 Compression ratio 17 : 1 Speed (RPM) 1500 Pistons speed (m/s) 7.75 Maximum stand-by power at rated RPM (kw) 294 Frequency regulation +/- 0.5% BMEP (bar) 19.11 Governor type COOLING SYSTEM Electronic FUEL Consumption @ 110% load (L/h) 77.60 Consumption @ 100% load (L/h) 63.10 Consumption @ 75% load (L/h) 47 Consumption @ 50% load (L/h) 31.30 Maximum fuel pump flow (L/h) 270 OIL Oil capacity (L) 25 Min. oil pressure (bar) 0.50 Max. oil pressure (bar) 10 Oil consumption 100% load (L/h) 0.0630 Carter oil capacity (L) 23 Radiator & Engine capacity (L) 50.50 Max water temperature ( C) 103 Outlet water temperature ( C) Fan power (kw) 10 Fan air flow w/o restriction (m3/s) 5 Available restriction on air flow (mm Water Column) 76 Type of coolant Glycol-Ethylene Thermostat ( C) 71-85 HEAT BALANCE Heat rejection to exhaust (kw) 254 Radiated heat to ambiant (kw) 35.20 Haet rejection to coolant (kw) 150.6 AIR INTAKE Max. intake restriction (mm EC) 635 Intake air flow (L/s) 335 EMISSIONS Emission PM (g/kw.h) 0.137 Emission CO (g/kw.h) 0.112 Emission HCNOx (g/kwh) Emission HC (g/kw.h) 0.332

ALTERNATOR CHARACTERISTICS GENERAL DATA Alternator ref. Number of Phase Power factor (Cos Phi) 0.80 AT02260T Three phase Altitude (m) 0 to 1000 Overspeed (rpm) 2250 Number of pole 4 Capacity for maintaining short circuit at 3 ln for 10 s No Insulation class H T class, continuous 40 C H / 125 K T class, standby 27 C H / 163 K AVR Regulation Yes Total Harmonic Distortion in no-load DHT <2.5 Total Harmonic Distortion, on load DHT <2.5 Wave form : NEMA=TIF <50 Wave form : CEI=FHT <2 Number of bearing 1 Coupling Direct Voltage regulation at established rating (+/- %) Recovery time (Delta U = 20% 500 transcient) (ms) Indication of protection IP 23 Technology Without collar or brush OTHER DATA Continuous Nominal Rating 40 C (kva) 318 Standby Rating 27 C (kva) 350 Efficiencies 100% of load 93.70 Air flow (m3/s) 0.43 Short circuit ratio (Kcc) 0.50 Direct axis synchro reactance unsaturated (Xd) 276 Quadra axis synchro reactance unsaturated (Xq) 166 Open circuit time constant (T'do) (ms) 2253 Direct axis transcient reactance saturated (X'd) 12.20 Short circuit transcient time constant (T'd) (ms) 100 Direct axis subtranscient reactance saturated (X''d) 7.30 Subtranscient time constant (T"d) (ms) 10 Quadra axis subtranscient reactance saturated (X"q) 9 Subtranscient time constant (T"q) (ms) 10 Zero sequence reactance unsaturated (Xo) 0.50 Negative sequence reactance saturated (X2) 8.20 Armature time constant (Ta) (ms) 15 No load excitation current (io) (A) 1 Full load excitation current (ic) (A) 3.40 Full load excitation voltage (uc) (V) 33 Engine start (Delta U = 20% perm. or 50% trans.) (kva) 694 Transcient dip (4/4 load) - PF : 0,8 AR 12.90 No load losses (W) 4800 Heat rejection (W) 16880 Unbalanced load acceptance ratio 100 DIMENSIONS Containment DW Commercial reference of the enclosure M228 DW Length (mm) 4527 Width (mm) 1410 Height (mm) 2700 Dry weight (kg) 4190 Tank capacity (L) 1368 Acoustic pressure level @1m in db(a) 81 Sound power level guaranteed (Lwa) 101 Acoustic pressure level @7m in db(a) 71

CONTROL PANEL APM303, comprehensive and simple TELYS, ergonomic and user-friendly The APM303 is a versatile unit which can be operated in manual or automatic mode. Equipped with an LCD screen, the user-friendly APM303 offers high-quality basic functions to guarantee simple, reliable operation and supervision of your generating set. It offers the following features: Measurements: phase-to-neutral and phase-to-phase voltages, active power currents, effective power, power factors, Kw/h energy meter Fuel, oil pressure and coolant temperature levels Supervision: Modbus RTU communication on RS485 Reports: 2 configurable reports Safety features: Overspeed, oil pressure Coolant temperatures Minimum and maximum voltage Minimum and maximum frequency Maximum current Maximum active power Phase sequence Traceability: Stack of 12 stored events For further information, please refer to the data sheet for the APM303. The highly versatile TELYS control unit is complex yet accessible, thanks to the particular attention paid to optimising its ergonomics and ease of use. With its large display screen, buttons and scroll wheel, it places the accent on simplicity and communication. The TELYS offers the following functions: Electrical measurements: voltmeter, frequency meter, ammeter. Engine parameters: working hours counter, oil pressure, coolant temperature, fuel level, engine speed, battery voltage. Alarms and faults: oil pressure, coolant temperature, failure to start, overspeed, alternator min./max., battery voltage min./max., emergency stop, fuel level. Ergonomics: wheel for navigating around the various menus. Communication: remote control and operation software, USB connections, PC connection. For more information on the product and its options, please refer to the sales documentation.

APM802 dedicated to power plant management The new APM802 command/control system is specifically designed for operating and monitoring power plants for markets including hospitals, data centres, banks, the oil and gas sector, industries, IPP, rental and mining. This unit is available as standard on all generating sets from 275 Kva designed for coupling. It is optional on the rest of our range. The Human Machine Interface, designed in collaboration with a company specialising in interface design, facilitates operations with a large 100% touch screen. The preconfigured system for power plant applications features a brand new customisation function which complies with the international standard IEC 61131-3. New communication functions (PLC and regulation), improve the high level of equipment availability in the installation. Advantages: Dedicated to power plant management. Specially researched ergonomics. High level of equipment availability. Modularity and long service life guaranteed. Making it easy to extend the installation For more information, please refer to the sales documentation.