ADDENDUM TO THE STC PRO LOGGER II MANUAL

Similar documents
1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL

Newcastle Weighing Services Pty Ltd

Clamp Earth Tester MET-2. Instruction Manual

Orica Seismic Electronic Initiation System OSEIS TESTER. Manual

MULTI FUNCTION POWER PAK PLUS

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

SafetyPAT Plus A B P/N:

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

FREQUENCY INVERTER INSTALLATION & USER GUIDE

Service Manual BLACK DIAMOND SERVICE MANUAL. V.160 November

Begin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A

Wallbox Commander. User Guide WBCM-UG-002-EN 1/11

ZoneTouch V2 Zone Control System Installation Manual

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

ECONOMISER SERIES E2T USER MANUAL

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

TRIPS AND FAULT FINDING

B-RAD Select USER MANUAL TABLE OF CONTENTS

KEWTECH. KT56 digital multi function tester. Instruction manual

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Does Your Electrical Safety Testing Routine Need a Boost? Exploring the Benefits of the Line Leakage and Functional Run Tests

Competition Electronics, Inc

Issue 2.0 December EPAS Midi User Manual EPAS35

PAT120, PAT150 and PAT150R

Section 55 Chapter 6

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

MODEL No s: PP3, PP3K

Motor Protection With The MonitorPro

1.Safe testing IMPORTANT:

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

I. Safety precautions

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

Atlas ESR and ESR + Equivalent Series Resistance and Capacitance Meter. Model ESR60/ESR70. Designed and manufactured with pride in the UK.

SimplePAT. Battery Powered Portable Appliance Tester. User Manual Issue 1.0

Level-Up Motorhome Leveling

Tracer VM with User Interface

EPAS Desktop Pro Software User Manual

UP100AC INSTRUCTION MANUAL

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

MoistureMatch A next generation grain tester

OmniScan MX2. Getting Started Guide. Intended Use. Instruction Manual. Safety Signal Words

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

INSTALL GUIDE AKX-IDS(RS)-BZ1B-[ADS-BZ1]-EN

Ground Control TT Leveling System OWNER'S MANUAL

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

SP PRO KACO Managed AC Coupling

INTRODUCTION. Specifications. Operating voltage range:

Galvanic Isolator. Instruction Leaflet

BATTERYLESS JUMP STARTER CAPACITOR INSTRUCTION MANUAL. W 2 AFTER SALES SUPPORT

INSTALL GUIDE IDL-IDS(RS)-BZ2B-[ADS-BZ2]-EN

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

:43 1/13 Victron & BYD B-Box

OpenEVSE - 40A Charging Station

Do isolate the power supply from other high power systems such as Stereos and Alarms

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Table of Contents. Chapter 1 Product Summary... 2

Intelligent Digital Balance Charger

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

POWER PAK II / PLUS II

CHAPTER 2: ELECTRICAL SAFETY

ZLogs Help. Tablet Applications. Contents. ZLogs Help

Components. Options Accessory Harness USB Charger. Quick Connector. Hook & Loop / Cable-ties. RFID Antenna. Module. Main Harness.

OPERATING INSTRUCTIONS

Support. EMROL Your power partner

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Safety Design of CHAdeMO Quick Charging System

Draft Unofficial description of the UNRC charger menus

Battery Jump Pack. Instruction Manual for P/N Lithium Iron Phosphate (LiFePO4)

Low Frequency Inverter. User Manual

install guide OEM-IDS(RS)-BM1-[ADS-BM1]-EN

MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33

Installation Guide Galvanic Isolator Gi50/32/S/SA - 120a Surge Current

MDX-645 INSTRUCTION MANUAL. Battery Conductance Analyzer. For 6 & 12-volt automotive starting batteries

KD LV Motor Protection Relay

Compact Solar Charger. Model Number ACSC-114 INSTRUCTION MANUAL

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Portable Power Solutions USER MANUAL

EV110. Electric Vehicle Supply Equipment Tester. Operating Instructions

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

POWERED BY KT71 / Portable Appliance Tester. Instruction Manual

Performance DSG Upgrade Installation Instructions using the Byteshooter tool version 1.4

Atlas ESR. User Guide. Capacitance and Equivalent Series Resistance Meter. Model ESR60 (Enhanced)

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

620 Magnolia Avenue Suite B Ontario, CA (909) Diagnostic and Troubleshooting. Golf Cart. Revision: A Date:

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

EV100. Electric Vehicle Supply Equipment Tester. Operating Instructions

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

MegOhmMeter. Users Manual

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

LRCD200 Series Combined Loop and RCD Tester USER MANUAL

Installation and Operating Instructions. Solar System Controller ISC3030

Thunder Power Tarp Kit Operation

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Transcription:

ADDENDUM TO THE STC PRO LOGGER II MANUAL 1. Probe Test for Testing Double Insulated Appliances (Utilities Menu) The SafeTcheck Pro Logger II now has a new feature Probe Test, available on all testers with Firmware Version V4.46 and above. By default Pro Loggers use the unique feature CheckConnect in conjunction with a Stainless Steel Cloak to perform an Insulation Resistance (IR) test on Double Insulated Appliances. CheckConnect ensures the Device Under Test (DUT) is both correctly connected to the Pro Logger (to provide a return path for leakage currents) and its exposed surfaces adequately covered to reduce the chance of an erroneous test result. During a Probe Test the CheckConnect feature is disabled. This gives the operator the ability to use the probe, the cloak or a combination of both to test Double Insulated Appliances. The test also provides adequate time to move the probe to several points on the DUT s surface before the test is complete. WARNING: Unlike CheckConnect the Probe Test does not look for a completed return circuit. A test conducted without a return circuit is an invalid test; unfortunately the Pro Logger II will still indicate a PASS test result. In some cases the operator may find that the Probe Test is more appropriate or convenient e.g. the size or physical location of the DUT may make it difficult to use the cloak or CheckConnect. To switch between the Double Insulated Probe Test and CheckConnect Options, go to the Utilities Menu under the F2 Key, Scroll down to the CheckConnect Option using the F2 Key and then select the required option. The selected option will always have a small rectangle to its right. NOTES: 1. TRIO Smartcal recommends the use of CheckConnect for most, if not all, IR tests on Double Insulated appliances. Failure to use this option with an incorrectly connected appliance may mean the test result is incorrect. This potentially dangerous situation exists with any Portable Appliance Tester without CheckConnect (please refer to the Warning above). 2. Correct use of the Cloak and CheckConnect is recommended to protect the operator from electric shock. This feature complies with the mandatory Safety Standard AS4024.1 SAFETY OF MACHINERY DESIGN AND OPERATION. Notice Issued: 28 th September 2012 Page 1 of 6

2. Three (3) Pin Class 2 Run Test (Other Appliance Menu) Appliances connected to the mains via a 3 pin plug with no Double Insulated (Class 2) symbol visible, should be considered Earthed Appliances (Class 1), however, with some appliances of this kind, the earth conductor provides not only a degree of electrical safety but also a path to conduct EMI currents, to reduce noise. This EMI current may cause an appliance to fail due to, what the Pro Logger sees, as excessive leakage. Also, with some other appliances, there is simply no practical way of finding a connection to the Earth Conductor i.e. it has no exposed earthed metal parts. To test these appliances, a Three (3) Pin Class 2 Run Test has been provided (via the Other Appliance Menu) with the Pro Logger. The first phase of this test, while running the appliance, looks for 1mA of leakage current between the Pro Logger s Cloak and the appliance s case i.e. a standard Double Insulated Run Test. If the Pro Logger measures more than this, it will try again with an increased 5mA threshold (because the appliance is Earthed, up to 5mA of Leakage Current is permissible). The person conducting the test will be warned that the 1mA threshold has been exceeded and that a 5mA test will be conducted. Any more than 5mA of leakage current will cause the test to fail. NOTE: This test does not look for the presence of an Earth Conductor. It should only be used if the normal Earthed Appliance Insulation Resistance Test continually has failed. 3. Additional function to discard failed Electrical Tests (Database function) A new feature has been added to the Data Logging function that gives a user the option to discard a failed Electrical Test is available on all testers with Firmware Version V4.56 and above. With the Data Logging Enabled, if an Electrical Test fails, then the user will be prompted to either: save the test information by selecting Start, or abandon the information by selecting Reset. This feature greatly reduces the number of records stored in the Pro Logger s memory. It also reduces the time for editing the resultant data file, if bad test data has been logged to memory i.e. a failed test that is not an Electrical Fail but the result of incorrect connection or setup. Notice Issued: 28 th September 2012 Page 2 of 6

4. Additional Two (2) Wire Lead Test (Lead Test function) Many modern appliances use a two wire mains power lead with a figure 8 style socket i.e. no earth conductor. The Pro Logger s Lead Test will now test this style lead as a Class 2 appliance (requires an adaptor STCIEC2F8). The Pro Logger will conduct an Insulation Resistance (IR) Test if the lead is found to have no earth by design (requires confirmation by the user). The IR is measured between the inner mains conductors and the Pro Logger s Cloak which is wrapped around the length of the lead. This feature is available on all testers with Firmware Version V4.64 and above 5. User option to bypass a Failed Continuity (Double Insulated & Earthed Appliance Test functions) (Utilities Menu - V5.20 only) While performing Insulation Resistance (IR) tests on Double Insulated or Earthed Appliances, it may be difficult, or even impossible, to complete the test because of a reported Continuity Failure. This may be a result of the appliance s Mains or On/Off Switch not being closed; or the Pro Logger interpreting a closed switch with high impedance, as not closed. If the Pro Logger reports a Continuity Failure, the Pro Logger presents the user with an option to bypass the error and proceed to the IR test. A user should only proceed if the following is true: 1. the user is satisfied that the appliance s mains switch is closed; and 2. the mains switch doesn t require mains power to be activated. This may be occur when testing Phone Battery chargers such as those for iphones. Applies to Firmware Version V4.67 to V5.09 & Hardware V7.0 For Firmware V5.20 and above & Hardware V8.0 this function may be turned on or off by selecting Fail on poor cont via the Utilities Menu (F2 Key). NOTE: If in doubt, do not bypass the Continuity Failure error. Always err on the side of caution and consider the test a failure. Notice Issued: 28 th September 2012 Page 3 of 6

6. RCD Trip Time Threshold (Portable 30mA RCD Test function) When testing Portable RCDs the trip current is suddenly applied and the trip time measured. In the case of 30mA Portable RCDs the acceptable trip time is 300mS however at 150mS (a threshold considered good practice AS37060:2010) the Pro Logger will fail the RCD in Firmware below Firmware Version V4.46; for V4.46 and above the Pro Logger will provide the user with a warning (not a fail) if the Trip Time is 150mS but 300mS. 7. Results Dump (Database function) A results dump function has been added to all Pro Logger IIs to enable test data to be streamed directly into 3 rd party software packages. While using the Pro Logger II in conjunction with FASTtag Asset Management Software, test data may be streamed directly to FASTtag s database; either in real time or after the completion of tests. The onboard database must be disabled (via the Utilities Menu) if results are streamed to the FASTtag Software in real time. Notice Issued: 28 th September 2012 Page 4 of 6

8. Three (3) Phase Run Test Option (Other Appliance Menu) Optional run (current leakage) testing of Portable 3 Phase Appliances in accordance with AS/NZS 3760. This option is available with 20 and/or 32A 3 phase sockets or other current ratings as requested. The test (via the Other Appliance Menu) looks for an Earth Connection <= 1 Ohm; a run current to ensure the appliance is switched on and running; and a leakage current of <= 5mA. The test is a Long Run Test. It may be shortened at any time after the test commences by pressing Reset twice in quick succession. If any of the test parameters (Earth Current, Run Current or Leakage Current) fail, then the 3 phase test fails otherwise the Pro Logger will indicate a pass. This test requires 2 connections to the Pro Logger: an earth return connection to the Device Under Test s (DUT) chassis; and a connection the 20 or 32A 3 phase socket adaptor (this is a din type socket in the well of the Pro Logger II). The 3 phase socket adaptor is plugged into a 3 phase power source, then the DUT into the 3 phase adaptor. The DUT should be running to conduct a test. To test a 3 phase extension lead, run a test with the extension lead connected between an already tested (and passed) 3 phase appliance and the 3 phase adaptor. Notice Issued: 28 th September 2012 Page 5 of 6

9. Battery Power Option (where fitted) Users of the Battery Power Option should note: 1. Insulation and earth testing only are available in Battery mode 2. To enter Battery mode press Start until the Pro Logger beeps (battery symbol in the bottom left corner of display will appear in this mode) 3. In Battery mode the Pro Logger will automatically shut down after 3 minutes, if no key is pressed 4. The Pro Logger may be switched from battery to mains without losing power (the battery will not charge in this mode - see Battery Charge Mode) 5. Failing to follow these instructions will reduce battery life and void the battery s warranty For a new Pro Logger ensure the battery is initially fully charged: 1. Power the Pro Logger from mains power 2. Set the Pro Logger into Charge mode (see below) 3. Wait for Charge Complete prompt to appear and then press Start 4. Turn the Pro Logger off by disconnecting the mains power Battery Charge Mode (following these steps will extend the life of the battery): 1. Power the Pro Logger from mains power (If already on, switch off and back on again) 2. The prompt select test needs to be displayed (If in database mode, press reset unil select test is displayed). The Battery will now be charging 3. Wait for the Charge complete prompt to appear 4. Press Start to acknowledge the charged condition 5. When fully charged the Pro Logger may be stored or it is ready for appliance testing NOTE: 1. While charging, do not select any tests, this will disable the battery charge mode (if this occurs, remove the mains power and restart the Battery Charge Mode sequence). 2. The battery will not charge while the Pro Logger is in Test mode 3. A low battery condition will display a screen message Low battery reconnect to mains 4. Storing the Pro Logger with a flat or partially charged battery will decrease the life of the battery 5. Recharge at least every 6 months, more often if possible TRIO Smartcal Pty Ltd ABN 79 119 968 491 10 James Street Thebarton SA 5031 Procedures may change without notice. Always check the www.safetcheck.com.au website for upgrade information. For more information regarding these features or for any questions relating to the STC Pro Logger II, please check the www.safetcheck.com.au website or call 1300 852 402 (Weekdays 8:30am 5:00pm CST) Sales: 1300 852 402 Service: 1300 852 402 Fax: 1300 853 409 www.safetcheck.com.au sales@triosmartcal.com.au Notice Issued: 28 th September 2012 Page 6 of 6