SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

Similar documents
SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

What you need to know. Â Conformity to standards

FUSIBLE DISCONNECT SWITCHES

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

SIRCO M and MV Universal load break switches from 16 to 160 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

Contents. Volume 5 Motor Control and Protection CA E December

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SHORT FORM CATALOGUE. ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98

An innovative technology

Load Break Disconnect Switches FSLBS

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

UL/CSA Non-fused Disconnect Switches

MANUALLY OPERATED CHANGEOVER SWITCHES

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Vistop TM isolating switches 63 to 160A

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

AF40... AF96 3-pole contactors Technical data

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

General information about motor protection

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Section Contents. Disconnect Switches

CATALOGUE MARINE APPLICATIONS. Energy performance solutions

SD Series Non-Fused Load Switches

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Breakers and Switches. Switches Switch-disconnectors OT and OTM

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

footprint of traditional fusible switches

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

Switch-disconnectors OT , OETL 3150

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

cor Long Run Experience

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

SWITCH DISCONNECTORS PLANET -SWITCH.

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

UL 98 Fusible Disconnect Switches

DPX Magnetic only

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

UL Enclosed Disconnect Switches (Fused and Non-Fused)


MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring:

Switching, control and protection solutions for solar applications

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

SFS-UFS Single Foot Switches

34.2 R5 Series (UL 508) Non-Fusible 16 80A MTS Manual Transfer Switches

Switch Disconnectors

TeSys GS. Data for Designers. Contents

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

.1 Introduction UL/CSA Standards for Disconnect Switches UL 98 Enclosed and Deadfront Switches (CSA C22.2 No. 4) These requirements cover enclosed or

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Overview for Fusible Disconnect Switches

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

for Non-Fusible Disconnect Switches

DPX earth leakage DPX 3 -I earth leakage

3 - Protection components Motor circuit-breakers

SPEEDFAX TM 2011 Disconnect Switches Contents

General Characteristics

Technical data OT16E3 OT160E3 UL & CSA

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

DRX 125 Circuit breaker (not adjustable)

LK Position Switches TECHNICAL DATASHEET.

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Disconnect Switches Compact, Heavy-Duty

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Selection Guide Motor Control Device Solutions

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Low Voltage Products. Switches Switch-disconnectors OT and OETL

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Wall mounted switchgear

SWITCH FUSES 3KL71 from 32A to 800A Description

Compact Circuit Protector

Industrial Contactors CTX 3 3P 185A - 800A

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Transcription:

Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability > Safety of property and personnel > Simplicity > Easy assembling Function SIRCO 3 x 600 A SIRCO non-fusible disconnect switches are heavy duty switches that break and make power circuits on and off load and provide safety isolation. These switches are extremely durable and are tested and approved for use in the most demanding applications. Conformity to standards (1) > IEC 60947-3 > UL98, Guide WHTY, file E201138 > CSA 22.2#4, Class 4652-04, file 703166 * General characteristics Positive break indication. Fully visualized disconnection. High thermal and dynamic withstand. Severe utilization categories. High electrical and mechanical endurance. (1) Product reference on request. Customized solutions > Please consult us 32 General Catalog UL/CSA Ed. 1

References Rating (A) No. of poles Switch body Direct handle External handle Shaft for external handle Auxiliary contacts Terminal protection screens Terminal Lugs kits 100 A 200 A 0 A 600 A 800 A 1000 A 2700 3011 2700 11 2700 3021 2700 21 2700 3041 2700 41 2700 3060 2700 60 2700 3080 2700 80 2700 3100 2700 4100 2699 5052 3799 6012 S2 type 1, 3R, 12 142F 2111 (1) Red/Yellow 1, 3R, 12 142G 2111 (1) 4, 4X 142D 2111 (1) Red/Yellow 4, 4X 142E 2111 (1) S3 type 4, 4X 143D 3111 (1) Red/Yellow 4, 4X 143E 3111 (1) 200 mm 7.9 inches 10 1020 320 mm 12.6 inches 10 1032 0 mm 15.7 inches 10 10 200 mm 7.9 inches 11 1520 320 mm 12.6 Inches 11 1532 0 mm 15.7 Inches 11 15 1 st contact NO/NC 2799 0021 2 nd contact NO/NC 2799 0022 2798 3021 (2) 2798 8021 (3) 2798 21 (4) 2798 3041 (2) 2798 8041 (3) 2798 41 (4) 2798 3060 (4) 2798 60 (4) 2798 3120 (4) 2798 4120 (4) 3954 3020 (4) 3954 20 (4) 3954 30 (4) 3954 (4) 3954 3060 3954 60 3954 3120 3954 4120 2700 3120 1200 A 2700 4120 (1) Defeatable handle. (2) Top. (3) Bottom. (4) Top or bottom. (5) Max. 4 ACs. Accessories Direct operation handle Rating (A) Color Handle type Reference 100... 0 B 2699 5052 600... 1200 H 3799 6012 acces_135_a_2_cat acces_114_a_1_cat H type handle B type handle General Catalog UL/CSA Ed. 1 33

Accessories (continued) External operation handle The interlocking function of the front external handle prevents the user from opening the door of the enclosure when the switch is in the "ON" position or when the switch is padlocked in the "OFF" position (S1, S2, S3 and S4 type handles only). Front handle I - 0 Opening the door when the switch is in the "ON" position is possible by defeating the interlocking function with the use of a tool (authorized persons only). The interlocking function is restored when the door is closed. Rating (A) Handle type Color Nema type Reference 100... 0 S2 1, 3R, 12 142F 2111 100... 0 S2 Red/Yellow 1, 3R, 12 142G 2111 100... 0 S2 4, 4X 142D 2111 100... 0 S2 Red/Yellow 4, 4X 142E 2111 600 1200 S3 4, 4X 143D 3111 600 1200 S3 Red/Yellow 4, 4X 143E 3111 600 1200 S4 4, 4X 144D 3111 600 1200 S4 Red/Yellow 4, 4X 144E 3111 Front handle heavy duty I - 0 with metallic lever Rating (A) Handle type Color Nema type Reference 100... 0 S2 4, 4X 142D 2911 100... 0 S2 Red/Yellow 4, 4X 142E 2911 600 1200 S3 4, 4X 143D 3911 600 1200 S3 Red/Yellow 4, 4X 143E 3911 600... 1200 S4 4, 4X 144D 3911 600 1200 S4 Red/Yellow 4, 4X 144E 3911 S2 type handle S3 type handle Heavy duty S2 type handle acces_236_a_2_cat acces_166_a_2_cat acces_150_a_1_cat S4 type handle acces_152_a_2_cat Shaft for external handle Standard lengths: - 7.9 in / 200 mm, - 12.6 in / 320 mm, - 15.7 in / 0 mm. Other lengths: please consult us. Rating (A) Dimension X (in) Dimension X (mm) Handle type Length (inches) Length (mm) Reference 100 0 5.31... 10.43 135... 265 S2 7.9 200 10 1020 100 0 5.31... 15.16 135... 385 S2 12.6 320 10 1032 100 0 5.31... 18.31 135... 465 S2 15.7 0 10 10 100 0 5.31 22.25 135 565 S2 19.7 500 10 1050 600 1200 8.70... 13.50 221 343 S3, S4 7.9 200 11 1520 600 1200 8.70... 18.23 221... 463 S3, S4 12.6 320 11 1532 600 1200 8.70... 21.38 221 543 S3, S4 15.7 0 11 15 600 1200 8.70 26.73 221 679 S3, S4 19.7 536 11 1554 (1) (1) UL pending, please consult us. Alternative color S-type handle cover acces_369_a_1_cat X acces_202_a acces_144_b_1_cat For single lever handles type S1, S2, S3 and double lever handle, type S4. Other colors: please consult us. Handle color Pack qty Handle type Reference Light grey 50 S2, S3 11 0001 Dark grey 50 S2, S3 11 0011 Light grey 50 S4 11 0031 Dark grey 50 S4 11 0041 acces_198_a_1_cat S-type handle raiser Enables S-type handles to be fitted in place of existing older style Socomec handles. Adapter can also be utilized as a spacer to increase the distance between the panel door and the handle lever. Dimensions Adds 12 mm to the depth. Handle color Pack qty Nema type Reference 10 1, 3R, 12 1493 0000 acces_187_a_1_cat 34 General Catalog UL/CSA Ed. 1

Shaft guide for external handle This accessory makes shaft introduction easier with up to 15 mm misalignment. Description Required for a shaft length over 0 mm. Reference Shaft guide 1429 0000 acces_260_a_2_cat Auxiliary Contacts Pre-break and color of positions 0 and I. Electrical characteristics A300 for 100 to 0 A. A600 for 600 to 1200 A. NO/NC contact for 100... 1200 A Rating (A) No. of AC Reference 100... 1200 1 st 2799 0021 100... 1200 2 nd 2799 0022 acces_076_a_1_cat NO/NC contact for 100... 1200 A Rating (A) No. of AC Reference 100... 1200 1 st 2799 0121 100... 1200 2 nd 2799 0122 Terminal screens Top or bottom protection against direct contact with terminals or connection parts. Rating (A) No. of poles Position Reference 100... 200 top 2798 3021 100... 200 bottom 2798 8021 100... 200 top / bottom 2798 21 0 top 2798 3041 0 bottom 2798 8041 0 top / bottom 2798 41 600 bottom 2798 3060 (1) 600 bottom 2798 60 (1) 800 1200 bottom 2798 3120 (1) 800 1200 bottom 2798 4120 (1) (1) Load side screen, the line side is included with the switch. acces_079_a_1_cat Terminal lugs Connection of bare copper cables onto the lugs (without lugs). Rating max (A) Wires range No wires per lug Lugs per kit Wires Reference 100... 200 #6-300MCM 1 2 Cu / Al 3954 2020 100... 200 #6-300MCM 1 3 Cu / Al 3954 3020 100... 200 #6-300MCM 1 4 Cu / Al 3954 20 0 #4-600MCM 1 2 Cu / Al 3954 20 0 #4-600MCM 1 3 Cu / Al 3954 30 0 #4-600MCM 1 4 Cu / Al 3954 0 2x (#6-350MCM) 2 2 Cu / Al 3954 2041 0 2x (#6-350MCM) 2 3 Cu / Al 3954 3041 0 2x (#6-350MCM) 2 4 Cu / Al 3954 41 600 2x (#2-600MCM) 1 2 Cu / Al 3954 2060 600 2x (#2-600MCM) 2 3 Cu / Al 3954 3060 600 2x (#2-600MCM) 2 4 Cu / Al 3954 60 800 1200 4x (#2-600MCM) 2 6 Cu / Al 3954 3120 800 1200 4x (#2-600MCM) 2 8 Cu / Al 3954 4120 ul_032_a General Catalog UL/CSA Ed. 1 35

Characteristics Characteristics according to UL98/CSA22.2#4 SIRCO UL98 - General use rating (A) 100 A 200 A 0 A 600 A 800 A 1000 A 1200 A Short circuit rating at 600 VAC (ka) 200 200 200 200 100 100 100 Type of fuse J J J J L L L Max. fuse rating (A) 100 200 0 600 800 1000 1200 Max. motor hp / FLA 3 ph motor max. 220-2 VAC 30 / 80 75 / 196 125 / 312 200 / 480 200 / 480 200 / 480 200 / 480 4-480 VAC 75 / 96 150 / 180 250 / 302 0 / 477 500 / 590 500 / 590 500 / 590 600 VAC 100 / 99 200 / 192 350 / 336 350 / 336 500 / 472 500 / 472 500 / 472 Max. motor hp / FLA 1 ph motor max. 220-2 VAC 10/50 10/50 Max. motor hp / DC FLA motor max. 125 VDC (1) 10 / 76 15 / 112 20 / 148 20 / 148 250 VDC (2) 15 / 55 15 / 55 50 / 173 50 / 173 Connection terminals Min. connection section / AWG #6 #6 2x #6 / #4 2x #2 4x #2 4x #2 4x #2 Max. connection section / AWG 300MCM 300MCM 2x 350 / 600MCM 2x 600MCM 4x 600MCM 4x 600MCM 4x 600MCM Mechanical characteristics Endurance (number of operating cycles) 10000 8000 6000 6000 3500 3500 3500 Operating torque (lbs.in/nm) 88.5/10 88.5/10 128.3/14.5 327.5/37 442.5/50 442.5/50 442.5/50 Auxiliary contacts Electrical characteristics A300 A300 A300 A600 A600 A600 A600 (1) 2 pole in series. (2) 3 pole in series. Characteristics according to IEC 60947-3 SIRCO UL98-600 to 1200 A Thermal current Ith ( C) 600 A 800 A 1000 A 1200 A Rated insulation voltage Ui (V) 1000 1000 1000 1000 Rated impulse withstand voltage Uimp (kv) 12 12 12 12 Rated operational currents I e (A) Rated voltage Utilization category A (1) A (1) A (1) A (1) 0 VAC AC-22 A 630 800 1000 1200 0 VAC AC-23 A 630 800 1000 1000 690 VAC AC-22 A 500 630 630 630 690 VAC AC-23 A 200 0 0 0 Connection Min. Cu cable cross section (mm²) 2 x 150 2 x 185 2 x 2 Min. Cu busbar section (mm²) 2 x 30 x 5 2 x x 5 2 x 50 x 5 2 x 60 x 5 Operational power in AC-23 (kw) At 0 VAC without prebreaking AC in AC23 (kw) (2)(3) 355 450 560 560 At 500 VAC without prebreaking AC in AC23 (kw) (2)(3) 450 560 560 560 At 690 VAC without prebreaking AC in AC23 (kw) (2)(3) 185 0 0 0 Overload capacity (U e 415 VAC) Rated short-circuit making capacity Icm (ka peak) (4) 48 75 48 75 (1) Category with index A = frequent operation. (2) A/B: Category with index A = frequent operation - Category with index B = infrequent operation. (3) The power value is given for information only, the current values vary from one manufacturer to another. (4) For a rated operating voltage Ue = 0 VAC. 36 General Catalog UL/CSA Ed. 1

Dimensions (in/mm) 100 to 0 A M J1 U Z Y 1 W R1 H N AA AC V K CA R2 sirco-ul_011_a_2_x_cat T F AD C 1. Terminal shrouds Rating (A) 100 200 0 Overall dimensions Terminal shrouds Switch body Switch mounting Connection J1 J1 M M Unit C AC AD F 3p. F 4p. H 3p. 4p. K 3p. 4p. N R1 R2 T U V W Y Z AA CA in 3.72 10.1 3.05 7.09 9.06 4.22 2.17 4.13 1.8 6.3 8.27 5.31 0.35 0.27 1.97 0.98 1.18 0.43 0.14 1.35 6.3 0.6 mm 94.6 256 77.5 180 230 107 55 105 45.6 160 210 135 9 7 50 25 30 11 3.5 34.4 160 15 in 3.72 10.1 3.05 7.09 9.06 4.22 2.17 4.13 1.8 6.3 8.27 5.31 0.35 0.27 1.97 0.98 1,18 0,43 0,14 1,35 6,3 0,6 mm 94.6 256 77.5 180 230 107 55 105 45.6 160 210 135 9 7 50 25 30 11 3,5 34,4 160 15 in 4.92 16 4.15 9.05 11.4 6.53 2.95 5.31 2.65 8.26 10.6 7.67 0.35 0.27 2.56 1.77 1.97 0.43 0.2 2.08 10.2 0.8 mm 128 6 115 230 290 166 75 135 67,5 210 270 195 9 7 65 45 50 13 5 53 260 20 600 A H M Z J Ø 0.51 Ø 13 Y X AC N N1 AA 3.15 80 F sirco_107_d_1_x_cat Rating (A) 600 Terminal shrouds Switch body Switch mounting Connection Unit AC F 3p. F 4p. H J 3p. J 4p. M 3p. M 4p. N N1 AA Z in 18.12 11 14.17 5.5 5 6.59 10.03 13.19 6.88 2.34 12.6 1.85 mm 460 280 360 1 127.5 167.5 255 335 175 59.5 320 47 General Catalog UL/CSA Ed. 1 37

Dimensions (in/mm) (continued) 800 to 1200 A H Z 0.78 20 Ø 0.43 Ø 11 J M Y X N1 8.85 225 sirco_228_d_1_x_cat AC N2 N 0.78 20 4.72 120 F Terminal shrouds Switch body Switch mounting Rating (A) Unit AC F 3p. F 4p. H J 3p. J 4p. M 3p. M 4p. N N1 800 in 18.12 14.64 19.37 5.5 6.83 9.19 13.66 18.38 6.88 2.34 mm 460 372 492 1 173.5 233.5 347 467 175 59.5 1 000 in 18.12 14.64 19.37 5.5 6.83 9.19 13.66 18.38 6.88 2.34 mm 460 372 492 1 173.5 233.5 347 467 175 59.5 1 200 in 18.12 14.64 19.37 5.5 6.83 9.19 13.66 18.38 6.88 2.34 mm 460 372 492 1 173.5 233.5 347 467 175 59.5 100 to 0 A Front direct handle 1.79 45.5 600 to 1200 A Front direct handle 2.36 60 5.31 135 sirco-ul_027_a_1_x_cat 7.48 190 sirco_267_b_1_x_cat Mounting orientation 3/4 pole 3.35 85 sirco-ul_028_a_1_x_cat 38 General Catalog UL/CSA Ed. 1

External handles dimensions (in/mm) 100 to 0 A Front operation Handle type Direction of operation Door drilling S2 type 0 90 Ø 3.07 Ø 78 1.77 45 4.92 125 I Ø 1.46 Ø 37 4 Ø 0.27 4 Ø 7 1.10 28 poign_013_a_1_us_cat 600 to 1200 A Handle type Front operation Direction of operation Door drilling S3 type Ø3.07 Ø78 90 I Ø 1.46 Ø 37 600 to 1200 A 2. 61 8.27 210 0 1.10 28 4 Ø 0.27 4 Ø 7 poign_046_a_1_gb_cat Front operation Handle type Direction of operation Door drilling S4 type I Ø3.07 Ø78 Terminal lugs (in/mm) 100 to 200 A 2.36 60 13.78 350 0 0 A 90 0 A 1.10 28 4 Ø 0.27 4 Ø 7 Ø 1.46 Ø 37 600 to 1200 A poign_036_a_1_us_cat 1.52 38.8 1 25 0.45 Ø11.6 1.12 28.6 sirco_115_b_1_us_cat 1.3 35 1.8 46 2.8 71.5 Ø 0.4 Ø 4.7 0.63 15.88 0.44 11.13 sirco-ul_010_b_1_us_cat 1.94 49.30 2.88 2 73.15 51 0.53 13.46 1.19 30.23 0.25 6.35 1.25 31.75 sirco-ul_026_b_1_us_cat 3.15 80 0. Ø10.2 1.49 38 2.87 73 sirco_116_b_1_us_cat 300 kcmil 600 kcmil 2 x 350 kcmil 2 x 600 kcmil General Catalog UL/CSA Ed. 1 39