Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Similar documents
Fusible Link (replaceable) Horizontal Mount

Fusible Link (replaceable) Horizontal Mount

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-331 Combination Fire Smoke Dampers

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-212. Combination FIRE SMOKE DAMPERS

Fire Dampers Catalogue

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

CURTAIN TYPE FIRE DAMPER

HCD-230 Industrial Control Damper

Motorized Fire Dampers

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

table of contents PRODUCT SUMMARY 2

MODEL 151B FIRE DAMPER

Fire, Smoke, and Combination Fire Smoke Dampers

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Life Safety Dampers - International. Fire Combination Fire Smoke Smoke Ceiling Radiation

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

SD-1250 and SD-1600 Series Smoke Dampers

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

VCD-23. Flange Options. Size Limitations

Model VCD-20 3V CONTROL DAMPER

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

MULTI-BLADE FIRE DAMPERS

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

MULTI-BLADE FIRE DAMPERS

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

Installation, Operation and Maintenance Instructions

SMOKE DAMPER - CLASS F MODEL BMSD

Smoke Dampers. Installation Instructions

AMD-33 Air Measuring Station with VCD-33 Control Damper

VCD-23 Low Leakage CONTROL DAMPER

CEILING DAMPERS GENERAL PRODUCT OVERVIEW CEILING DAMPERS MODELS 0716, , 0714 & 0722 FOR SQUARE, RECTANGULAR OR ROUND DUCTS

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

VCD-23. Low Leakage CONTROL DAMPER

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Dynamic & Static Rated Fire Dampers, Ceiling Radiation Dampers. UL Classified High Free Area Minimal Pressure Drop

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

CURTAIN FIRE DAMPERS GENERAL PRODUCT OVERVIEW

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

BC 03. Fire Dampers FD-GB-30-AS LISTED

Propeller Hooded Roof Fans

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Installation, Operation and Maintenance Manual

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

CFSD Series. Product Description

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

PRODUCTS BULLETIN PRODUCTS CATALOGUE

Model FDD Dynamic Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

Model FD Static Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

Thermal Isolation. Break

Part # Installation,Operation and Maintenance Instructions

AIR DUCT ACCESSORIES

Model VCD-43 Extruded Airfoil Blade Control Damper

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

RECEIVING AND HANDLING INSTALLATION SUPPLEMENTS WARRANTY SAFETY WARNING:

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

Standard Installation Fire/Smoke Damper Models: FR1, FR2 Smoke Damper Models: SR1, SR2

Dynamic & Static Rated Fire Dampers, Ceiling Radiation Dampers. UL Classified High Free Area Minimal Pressure Drop

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Nobody delivers dampers and louvers faster!

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

CEILING & INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

Standard Installation Combination Fire/Smoke Damper Models: FS1(SS), FS2(SS) Fire Damper Models: MD19(SS)

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

High Capacity Ventilation

series FSD-FLD Fire and smoke dampers UL Approval

Standard Installation Combination Fire/Smoke Damper Models: FS1, FS2, FT1, FT2, FA1, FA2, TA1, TA2, FS2C2 Fire Damper Models: MD19, MD39, MA19, MA39

Installation, Operation and Maintenance Manual

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES

CEILING VENTILATOR ACCESSORIES 6393 Powers Avenue Jacksonville, Florida P: / F:

Transcription:

Application Model FD-50 is a static rated fire damper approved for use in walls and partitions with fire resistance ratings of hours or more. This model carries a hour UL fire damper label. UL555 classifies static rated fire dampers for use in HVAC systems that are automatically shut down in the event of fire. Ratings UL555 Fire Resistance Rating Fire Rating: hours Model FD-50 Static Rated Fire Dampers Hour Fire Resistance Rating Construction Standard Optional Frame Material Galvanized Steel* - Frame Depth 11 16 in. (94mm) Blade Material Galvanized steel* - Closure Spring Stainless Steel - Fusible Link 165 F (74 C) 212 F (100 C) Mounting Vertical Horizontal * in gauges required by UL listing R-117 - * These dimensions are furnished approximately 1 4 in. (6mm) undersize. See complete marking on product. UL 555 Classification R117 Optional Features Sealed transitions (sleeve required) and sleeves Security Bars One piece retaining angles (POC) Transitions (B, B2, C, CO, CR, R) Model FD-50 meets the requirements for fire damper established by: National Fire Protection Association (NFPA Standards 80, 90A & 101) Underwriters Laboratories Standard 555 (Listing #R117) IBC International Building Codes California State Fire Marshall (Listing #225-981:102) Stainless Steel Closure Spring Fusible Link (replaceable) K side Horizontal Mount Installation All fire damper installations require the use of sleeves, angles and methods described in Greenheck Fire Damper Installation Instructions. Sleeves can be field fabricated or factory furnished as a complete damper/sleeve assembly. See Factory Sleeve Option below for details. Installation instructions available at www.greeenheck.com.

Factory Sleeve Option FD-50 FD-50 Fire Dampers are available in factory furnished sleeves. Sleeves are galvanized steel and are available in 10 thru 20 ga. (1mm -.5mm) thicknesses and lengths up to 6 in. (914mm). K dimension specifies location of damper within the sleeve. Minimum is 4 in. (102mm), maximum is L less 4 in. (102mm), which allows for mounting angle installation and duct connection at each end of sleeve. If K dimension is not specified, it will be provided as one half of L dimension (damper centered in sleeve). Note: If using access doors, the door should be installed on the K side of the damper. Sleeve Damper K Damper CL Damper Frame Location L Overall Sleeve Length When sealed option is selected, B transitions will need to be field sealed in the area where duct to sleeve connection is made. with sleeve corner profile

FD-50 Dampers larger than maximum single section size are supplied in 2 or more sections of equal size. If ordered with a factory sleeve, multi-section dampers are factory assembled ready for installation. If ordered without a factory sleeve, multi-section dampers require field assembly. The following chart show minimum and maximum damper sizes. Dimensions are in inches (mm in parentheses). Size Limitations Inches (mm) Vertical Horizontal Multi Horizontal** & B2 Minimum Maximum Minimum Maximum 4 x 4 (102 x 102) 4 x 4 (102 x 102) ** Consult factory for number of sections. 48 x 48 (1219 x 1219) 40 x 40 (1016 x 1016) 80 X 40 (202 X 1016) 4 x (102 x 76) 4 x (102 x 76) 48 x 42 (1219 x 1067 40 x 5 (1016 x 889) 80 X 5 (202 X 889) W * P * These dimensions are furnished approximately 1/4 in. (6mm) undersize. Maximum Dimensions Multi- Limitations (horizontal only) 40" max. 80" max. Sizing Data FD-50 & B2 Dampers larger than maximum single section size are supplied in 2 or more sections of equal size. Note: All multiple section dampers with transitions, will include a factory installed sleeve. 2 1 1/2 in. Varies 1 1/2 in. 42" max. (vert.) 5" max K dim. 80" max. Sleeve Length Varies

FD-50 & B2 cont... & B2 Overall Damper Dimensions 5 (127) 2 (584) 27 (686) 4 (102) 6 (152) 24 (610) 28 (711) 5 (127) 7 (178) 25 (65) 29 (77) 6 (152) 8 (20) 7 (178) 9 (229) 8 (20) 10 (254) 26 (660) 0 (762) 27 (686) 1 (787) 28 (711) 2 (81) 9 (229) 11 (279) 29 (77) (88) 10 (254) 12 (05) 0 (762) 4 (864) 11 (279) 1 (0) 1 (787) 6 (914) 12 (05) 14 (56) 2 (81) 7 (940) 1 (0) 15 (81) (88) 8 (965) 14 (56) 16 (406) 4 (864) 9 (991) 15 (81) 18 (457) 16 (406) 19 (48) 5 (889) 40 (1016) 6 (914) 41 (1041) 17 (42) 20 (508) 7 (940) 42 (1067) 18 (457) 21 (5) 8 (965) 44 (1118) 19 (48) 22 (559) 9 (991) 45 (114) 2 20 (508) 2 (584) 21 (5) 24 (610) 40 (1016) 46 (1168) 41 (1041) 47 (1194) 22 (559) 26 (660) 42 (1067) 48 (1219) Sizing Data FD-50 Type CR, C, CO & R Dampers larger than maximum single section size are supplied in 2 or more sections of equal size. Note: All multiple section dampers with transitions, will include a factory installed sleeve. The following chart show minimum and maximum damper sizes. Dimensions are in inches (mm in parentheses). Inches (mm) Vertical Horizontal Multi Horizontal** Type CR Type C & CO Type R*1 Minimum Maximum Minimum Maximum Minimum Maximum 41 (1041) 4 (864) x (76 x 76) x (76 x 76) ) ** Consult factory for number of sections. 46 x 41 (1168 x 1041) 8 x 4 (965 x 864) 78 X 4 (1981 X 864) 46 (1219) 8 (1016)

FD-50 Type CR, CO, C & R D*+2 Type C Type CR 41" max. (vert.) D* +2 ons 46" max. (vertical) Type CO Type CO +2 41" max. (vert.) Type C 46" max. (vertical) C, CO, CR transitions are positioned 1 in. (25mm) Type CR Type R from bottom of sleeve 1 in. (25mm) off bottom 4 in. (102mm) min. 41 in. (1041mm) max. (vertical) or D* or D* 6 (152) 2 (584) 28 (711) 4 (102) 7 (178) 24 (610) 29 (77) 5 (127) 8 (20) 25 (65) 0 (762) 6 (152) 9 (229) 26 (660) 1 (787) 7 (178) 10 (254) 27 (686) 2 (81) 8 (20) 11 (279) 28 (711) (88) 9 (229) 12 (05) 29 (77) 4 (864) 10 (254) 1 (0) 0 (762) 6 (914) 11 (279) 14 (56) 1 (787) 7 (940) 12 (05) 15 (81) 2 (81 8 (965) 1 (0) 16 (406) (88) 9 (991) 14 (56) 18 (457) 4 (864) 40 (1016) 15 (81) 19 (48) 5 (889) 41 (1041) 16 (406) 20 (508) 6 (914) 42 (1067) 17 (42) 21 (5) 7 (940) 44 (1118) 18 (457) 22 (559) 8 (965) 45 (114) 19 (48) 2 (584) 9 (991) 46 (1168) 20 (508) 24 (610) 40 (1016) 47 (1194) 21 (5) 26 (660) 41 (1041) 48 (1219) 22 (559) 27 (686) in. (76mm) min. 46 in. (1168mm) max. (vertical) * All multiples section dampers, with transitions, will include a factory installed sleeve. * Dimensions are inches (mm). These dimensions are furnished approximately 1 4 in. (6mm) undersize, except round and oval dimensions (D, H, W) are approximately 1 8 in. (mm) undersize. (All H dimensions larger than single section height are two sections high. Refer to chart.) Copyright 2018 Greenheck Fan Corporation FD-50 Rev. 9 May 2018