DEMA SQUIRT DRAIN UNIT

Similar documents
BIOACTIVE SOLUTIONS AC DRAIN STATION

DEMA Nitro for Europe Ware Wash Chemical Dispensing

Trapper Drain Maintenance/Odor Control Chemical Dispensing

Drain Chief Plus Drain Maintenance/Odor Control Chemical Dispensing

DART Ware Wash Speed Control

DEMA S.U.D.S Jr. SINGLE PRODUCT LAUNDRY 581K(I)(S)(V)

Trident Laundry Chemical Delivery System

DEMA Dispensing. Overview. Warnings. I-1205 Rev. B a digital ware. The DEMA. Nitro Plus is. tee.

DEMA 951 FLUSH MANIFOLD WITH 24V DC VALVE INSTALLATION INSTRUCTIONS

DEMA SINGLE PRODUCT LAUNDRY MASTER TM W/BLEACH OPTION INSTALLATION INSTRUCTIONS LIQUID MODEL 840 (B)(S)

23200 Navigator Dilution Control System 4 Button Model (NAV 4)

I Button Chemical Dispenser. Overview. Installation Instructions

ALWAYS FOLLOW ALL SAFETY PRECAUTIONS AS DIRECTED BY THE CLEANING CHEMICAL LABEL

DEMAMaster TM DM-811 Series Installation Manual

DEMA 259B DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

Spray Clean 606T-2 Installation Instruction

665 Series Dispenser. Metering tip kit

DEMA Pro-Fill I Sink Dispenser

DEMA Pro-Fill II Sink Dispenser

INSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP

DEMA DILUTION-AT-HAND EXTREME 800 Series Chemical Dispensers

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

DEMA MODEL 582 FOAM STATION III INSTRUCTION SHEET

WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT,

DEMA SPRAY CLEAN MODELS: 244BC, 244BCE, 244BCP & 244BCT INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

DEMA 652 DUO-FEED INSTALLATION INSTRUCTIONS

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

DEMA SPRAY CLEAN MODELS: 244CDF & 244CDFT INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

PeroxiDraw Dispenser

DEMA MODEL 604T-WI INSTALLATION INSTRUCTIONS

DEMA MODEL 603T-WI INSTALLATION INSTRUCTIONS

DEMA MODELS 606T INSTALLATION INSTRUCTIONS

DEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION

The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.

DEMA RAPID FIRE MODELS 6300, , , , 6310, 6300H 6300E, 6300EH, &6310E INSTRUCTION SHEET

Spray & Foam Dispenser Item #

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER IS NOT IN USE.

DEMA MODEL 606T-WI INSTALLATION INSTRUCTIONS

TABLE 1. * SPECIFY S Stainless Steel Knob Part No S or Part No ST (for tips) for pressure exceeding 700 PSI.

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

DEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS

DEMA 651AG SINGLE-FEED INSTALLATION INSTRUCTIONS

DEMA 257C / 257CV PRO BATTERY DRAIN CHIEF INSTALLATION & OPERATING INSTRUCTIONS

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

Items # and #

DEMA SPRAY CLEAN MODELS: 241CDF & 241CDFT INSTALLATION INSTRUCTIONS

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

DEMA SINGLE-FEED MODEL: 651GAP& 651GAP-1 INSTALLATION INSTRUCTIONS

Caution! Pg. 1 of 5 I-932

Certo Chemical Dilution System

900-WC OWNER S MANUAL THIS UNIT DOES NOT INCLUDE AWATER BACKFLOW PREVENTER, CHECK LOCAL PLUMBING CODES FOR PROPER INSTALLATION. Pg.

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

DEMA Model 294D Spray Foam INSTALLATION INSTRUCTIONS

Reference Manual FM-200 Series

Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5

Intended Use: Explanation of Signal Word Consequences

SAFETY INFORMATION & INSTRUCTION MANUAL

D EMA TWO-STAGE INJECTOR MODELS 233, 234A, 236A, 236-8, 238, AND 2312 INSTALLATION INSTRUCTIONS FIGURE 3 FIGURE 2

DEMA MIXRITE PROPORTIONING PUMP MODELS 574 & CL & 575CL FOR CORROSIVE LIQUID CHEMICALS INSTALLATION INSTRUCTION.

910 BHF OWNER S MANUAL. Pg. 1 of 9

MITYFLEX PERISTALTIC PUMPS

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

ILCS EDGE Jr EDP Installation Manual

ILCS EDGE System Installation Manual

RK Standby Battery Operator s Manual

PORTABLE TUBING PUMP MANUAL

ECLIPSE Laundry Dispenser Controller

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

Remove the 3-11mm nuts holding mirror on. Don t drop the nuts!

OWNERS MANUAL JANUARY 2007 ISO

450250/ ROOSTER WINCH Installation Manual

OP-500 On-Premise Series Instruction Manual

ADI-125/750 ADI-125/1500 ADI-125/2500

Foam Output 50 gal/min (190 ltr/min) 65 gal/min (246 ltr/min) Foaming Distance 30 feet (9 meters) 35 feet (10 meters) alcohols, ketones.

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

i n s t r u c t i o n m a n u a l

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

Precision Water Systems CBR-2 Bottle Rinser. Owners Guide Model: CBR-2 BOTTLE RINSER Part No: Series: 001

RK Standby Battery Operator s Manual

50 Gallon Skid Sprayer

DC to AC Power Inverters

Tools Needed for Mounting Cleá Filling Station

DC to AC Power Inverters

Export Bucket Pump Instruction Manual Models: 2114XE & 2114XD

Dilution Control Systems. Multi-Task Dispenser Model #421700PL OPERATION SERVICE PARTS CARE. Dema #i GAPDB-MC2

SOLUTION STATION Instruction Manual

150 Gallon 3- Point Hitch Sprayer

Installation, Operation, Repair and Parts Manual

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

StormPro BA Series Sump Pump

MIL-24/2600Q MIL-24/3200DQ

EXT HEPA/CARBON FUME HOOD

WARRANTY POLICY FOR LD SERIES LABEL DISPENSERS REPAIR POLICY

Transcription:

DEMA SQUIRT DRAIN UNIT Overview The Squirt is a chemical dispenser with a programmable timer designed primarily for dispensing chemicals into drains. Its most clear intended use is for drain applications when a degreaser is needed in the drain daily, or every other day. The timer is programmable to run up to 8 events that can be set for a specified amount of time to run the pump. Warnings Installation of DEMA products must meet all applicable electrical codes and regulations established by national, city, county, parish, provincial or other agencies. It is possible that electrical codes and regulations require that a certified electrical contractor or engineer perform the electrical installation. For questions, contact a certified electrician. ALL ELECTRICAL POWER MUST BE TURNED OFF TO THE DISPENSER AND TO THE APPLIED MACHINE. All installations must conform to local plumbing codes and use approved backflow prevention devices. A pressure indicating tee is to be installed with existing faucets according to local plumbing codes in the state of Wisconsin and any other state that requires the use of a pressure indicating tee. ALWAYS WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN WORKING WITH CHEMICAL PRODUCTS. I-984 Page 1 of 5

Specifications Packing List 25.20.1 SQUIRT DRAIN UNIT 25.69.8 SWITCHING POWER SUPPLY (115-240 VAC) 20 ¼ OD TUBING 30.41 SCREW AND ANCHOR KIT 81.312.1 TUBE STIFFENER POWER ADAPTER I984 INST. SHEET SQ. TUBE 2500 1 1 25.68.20 1 1 OMIT 1 81.231.1 2501 1 1 25.160.20 1 1 25.236.02 1 81.231.4 2502 1 1 25.68.20 1 1 25.19.2 1 81.231.1 2503 1 1 25.68.20 1 1 OMIT 1 81.231.1 Operational Requirements For indoor use only Main Power 120-240 VAC 50-60 HZ Case Material ABS Product Weight.5 kg 1.15 LBS The integrity and operational characteristics of this unit are not guaranteed outside the above mentioned parameters. Use of this unit outside of these parameters nullifies warranty. Overall Size & Weight Parts List NO. PART NO. DESCRIPTION 1 25.21.1 PUMP, MOTOR, HOUSING 2 25.21.2 TIMER AND BOOT REPLACEMENT KIT 3 25.21.3 PUMP 25.21.4 SQUEEZE TUBE SINGLE 4 25.21.5 SQUEEZE TUBE REPLACEMENT BULK (5) KIT 6 25.21.6 BRACKET AND BOOT 25.21.7.US POWER SUPPLY KIT FOR US 7 25.236.02 POWER SUPPLY KIT FOR UK, EUROPEAN & AUSTRALIAN I-984 Page 2 of 5

Installation Mount the unit no higher than 6 feet from the chemical container. Take into account the proximity to the chemical, drain, and power for the unit. Use the included screw and anchor kit to secure the mounting bracket to the wall and then mount the unit on the wall. Then cut the tubing to the proper length to reach from the chemical container to the unit and the unit to the drain where the chemical is being dispensed. Squeeze Tube Installation Install the squeeze tube by removing the pump cover by depressing the tab on the front of the unit. (1) Place one end of the squeeze tube on the left side of the pump in the slot provided. (2) Wrap the squeeze tube around the rollers of the pump. (3) Then stretch the squeeze tube so that the end of the tube goes into the slot provided. (4) Replace the cover on the pump. (1) (2) (3) (4) Retaining Clip There is a clip on the bottom of the unit. This is to help relieve strain on the power cord. Place the power cord through this strain relief to help the power cord from coming unplugged from the unit. Clasp Close Pump Heads The pump heads have an added feature which will help to ensure the pump head is installed properly. When pushing the pump head on be sure to see the clip is fully covering the notch as seen in the first picture. If the tab is not fully engaged, there is a possibility of it popping off the pump head as seen in the second picture. Operation Programming the Dispenser - Reset timer before programming. Note: If a mistake is made during the programming, simply push the reset button and start over. A. 12 Hour or 24 Hour (Military) Mode Hold the Clock button down for 5 seconds or more to change back & forth to between the 12 & 24 hour modes. B. Set the Time and Day When the unit arrives the display may be blank or may display a time. Plug the unit into an outlet before programming. NOTE: Make sure that the bar in the bottom of the display is over the word OFF if it isn t, press the MANUAL button until it is. 1. To set the time and day of the week, hold the CLOCK button in and press the day, hour, and minute buttons until the proper day, hour, and minute is achieved. Note: The days will be across the top of the screen and will advance as the button is hit. The time must be set to AM and PM it is in the left top corner of the display. By holding in the Day, Hour, or Minute button for three seconds the setting will continue to advance until the button is released. I-984 Page 3 of 5

B. Programming the Dispensing Events: Up to 8 independent dispensing events can be programmed 1. Press and release the TIMER button to enter the programming mode. The event number will be in the bottom left corner. Note: To program a full event, a pump start time and stop time will have to be programmed. NOTE: THE PUMP WILL RUN FOR 23 HRS 59 MIN IF A START TIME IS SET BUT NOT A STOP TIME. a) Press the DAY button until all of the days are shown that the first event should be turned on. b) Press the HOUR and MINUTE buttons until the time is reached when the pump should turn on. Note: AM or PM in top left corner of screen. 2. Press and release the TIMER button again to move to programming the pump to turn off. a) This program will be used to turn the pump off. Use the pump s output to determine how long the pump must run to dispense the desired amount. b) Press the DAY button until the days match the days programmed in the pump on portion of the programming. c) Press the HOUR and MINUTE buttons until the desired run time is reached. 3. To program another event, press TIMER button again for Programs 2-8 and follow Programming Steps 1 and 2 above. Every ON function needs a corresponding OFF function in order to turn the pump off. 4. When finished programming, push the CLOCK button again to return to time of day (normal) display. C. Priming the Pump 1. To prime the pump, press the MANUAL button the bar at the bottom of the display will move from right to left from OFF to AUTO to ON. When it reaches ON, the pump will run until the MANUAL button is pressed again. Use this position to prime the pump as well as to calibrate the pump. To stop priming press the MANUAL button the bar at the bottom of the display will move from left to right from ON to AUTO to OFF. Note: The unit may continue to run in the AUTO position and the MANUAL button must be pressed until the bar at the bottom of the display is over the OFF position to stop the unit fully. D. Setting into Programmed Position 1. Press the MANUAL button until the bar in the bottom of the display moves from the OFF to the AUTO position. If the unit is not in the AUTO position, the program will not be executed. Specifications: When the unit is powered the first time, the rechargeable display back up battery begins charging. When fully charged it provides approximately 200 hours of reserve time before the display and program may be lost. If the unit loses power, it will not lose the program for 200 hours, but it will not run the pump from the rechargeable display back up battery and will not dispense chemical. If the unit becomes unplugged from the wall for a short amount of time, plugging the unit back in will not affect the programming done to the unit. Wiring Diagram TIME ml pumped oz pumped 1 min 110 ml 3.5 oz 3 min ~295 ml ~10 oz 5 min 550 ml 17.5 oz 6 min ~590 ml ~20 oz 10 min 1100 ml 35 oz 20 min 2200 ml 70 oz The wires are labeled with the colors and clearly connect to the timer for proper operation. I-984 Page 4 of 5

Troubleshooting Symptom Probable Cause Remedy Pump running when it is not programmed to. Pump is not priming like it should be or not holding a prime. Pump over feeding (using too much chemical). Pump under feeding (not enough chemical). Pump runs constantly. 1. The program, date, and time are set wrong. 2. Did not program an off time. 1. Hole in the tubing from the chemical container to the pump head. 2. Hole in the squeeze tube in the pump head. 3. Pick up tubing is not sealed to the squeeze tube fitting. 1. The programs entered in the unit were set wrong. 1. Did not match the Event #, Days or AM/PM for the off time. 1. Check the program, date, and time to make sure they are set properly. A common mistake could be where an AM is supposed to be a PM. 2. Check the programs for an off time for each program. 1. Check the tubing from the chemical container to the pump head for leaks by feeling the tubing for chemical that has leaked out. Replace the tube if necessary. 2. Replace the squeeze tube after inspecting it for a possible hole or leak. 3. Tighten the nuts on the squeeze tube fitting. 1. Check the program(s) to make sure they are set properly. A common mistake could be where an AM is supposed to be a PM. 1. Check the programs for an off time for each program; make sure the events are matched up. Warranty Merchandise Returns No Merchandise will be Returned for Credit Without DEMA S Written Permission. Returned Merchandise Authorization Number is Required in Advance of Return. Product Warranty DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture. This limited warranty does not apply to any products that have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, physical abuse, or misapplication. Rubber and synthetic rubber parts such as O -rings, diaphragms, PVC tubing, and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty is void. Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them to be defective, they will be repaired or replaced without charge, F.O.B. factory. DEMA assumes no liability for damages. Return merchandise authorization number must be granted in advance of returned units for repair or replacement (See Merchandise Returns above). I-984 Page 5 of 5