Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

Similar documents
INTRODUCING THE NEW MINI INVERTERS BY READY-LITE

RELIABILITY THROUGH TECHNOLOGY

STL. Series. Emergency Lighting Inverter 3kW to 160kW Central System

GLX. Series. 1kW to 16kW Central System

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

systems Systems Emergency Lighting Inverter 120 or 277V 60 Hz Power

DLTC. lighting controls. transfer circuit for use with low-voltage down-lighting. features

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

UL AND CODE COMPLIANCE

Illuminator Series CR NEMA 3R

CODE MANDATED INTERIOR EMERGENCY LIGHTING:

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

Installation And Operation Instructions

EMEX. Central Battery Systems Emergency Lighting

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

Installation Instructions Central Battery Units

Micro Lighting Inverter

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Explosion Proof Emergency Exit Sign - 90 Minutes Battery Backup - 120/277V - Emergency Lighting Syst

Installation And Operation Instructions

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

CEPS Series UL924 Emergency Lighting Inverters

Installation And Operation Instructions

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems

3 Uninterruptible Power Systems

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Sola/Hevi-Duty S3K Series Mini-Tower UPS

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

Project. Comments. Prepared by

Sure-Lites LPXC SERIES. Input Voltage Input Power 19 3/4" " /8" /8" 54 13" /2" 191

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Installation and Operation Instructions SERVICE BY QUALIFIED PERSONNEL ONLY

Uninterruptible Power Systems

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

Installation and Operation Instructions 10/04/13

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Uninterruptible Power Systems

Sola 3000 Guide Specifications

LMI Watt Models

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

EFFEKTA Power Supplies

UV16 vandal resistant, wet/damp location emergency lighting

Model ES VA to VA SINGLE PHASE UNINTERRUPTIBLE POWER SYSTEM

SURE-LITES LIFEWAY II Series C & IPS

POWER kva

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Self-Testing Industrial Series

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Illuminator System Series CIII

Special Specification 6058 Battery Back-Up System for Signal Cabinets

SPECIFICATION SHEET : FHS2-UNV-36L

3 Uninterruptible Power Systems

POWER kva

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

SECTION DC POWER SUPPLY/BATTERY CHARGER

TLE Series UPS 160/200/225/250 kw with eboost Technology

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

.3 Section Waste Management and Disposal.

POWER WAVE 1 SINGLE-PHASE, (3 TO 20 KVA) & (3 TO 17 KW) UL924 CENTRAL LIGHTING INVERTER

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Ampd Silo. Energy Storage System. Maintenance-free Li-ion energy storage for mission critical backup. Power to Empower

150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B

SAFETY WARNINGS AND GUIDELINES

Fixed Head Emergency Lights

Spectron Industrial Series

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

TLE Series UPS 400/500 kw With eboost Technology

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

To The. We ve Taken Exit Signs. Elegant Styling Industry-Leading Quality And Performance Easy, Trouble-Free Installation

Technical Data Sheets

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

PowerVerter 750W RV Inverter/Charger with Hardwire Input/Output

Emergency Lighting Products Limited

Technical Data Sheets

LIEBERT APM 3-PHASE UPS: 15-90KVA/KW, 60HZ, VAC, SINGLE & DUAL INPUT - SITE PLANNING DATA

3 Uninterruptible Power Systems

SURE-LITES LIFEWAY II SERIES

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Crucial Power Products

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

Transcription:

APPLICATIONS LLMPS Series inverter systems are designed to provide sinusoidal AC emergency power to incandescent, flourescent, or LED fixtures of between 20 and 55 watts. Surface, recessed or ceiling T-Grid mount models are designed for easy installation either on or near controlled fixtures. MPS models support normally-on, normally-off or switched operation FEATURES For powering Incandescent, flourescent and LED fixtures* True sinusoidal AC pulse width modulated (PWM) design provides clean 60 Hz. emergency output Universal 120/277VAC, 60Hz. input/output Unit capacities from 20 to 55 Watts Soft Start design reduces fixture inrush current Lumen output from fixture is 100% of nominal Surface, recessed or T-Grid mount models Unique design eliminates compatibility problems Normally-on or Normally-off load output Provisions for local switching capability - Always on during mergency conditions regardless of local switch position Temperature compensated, dual-mode charger includes low voltage disconnect feature to provide protection against battery deep discharge Maintenance-free Lead-Calcium and premium grade Nickel-Cadmium battery models offered Control panel with momentary test switch, AC-On, Charge-On and Inverter-On LED indicators Battery circuit fuse protected Reverse battery and AC lockout protection Meets NFPA Life Safety Code 101, OSHA, NEC, State and local Codes UL 924 listed Optional T-Grid model is plenum rated * Consult factory for compatibility for other lamp types PAGE 1 OF 5

APPLICATION The LLMPS Series is designed to provide 20- to 55-watts of emergency power to incandescent, flourescent, and/or LED fixtures. The LLMPS unit provides clean, sinusoidal AC output power allowing it to beremotely mounted up to 1,000 feet away from the controlled fixture(s). Unlike a ballast flourescent emergency pack, the MPS provides power to the input side of the fixture, (including the ballast), eliminating any chance of incompatibility. LLMPS Series models are available for surface, recessed or ceiling T-Grid mounting if required. All MPS systems will provide emergency power output for a minimum of 90 minutes. CONSTRUCTION Housing: Heavy duty steel cabinet is finished in white baked-on powder paint providing scratch and corrosion resistance. Optional special color paint (-SP) finishes available, consult factory. MOUNTING Surface Mount: Surface mount models are designed for mounting to walls by means of keyhole slots provided in the back of the unit housing. Recess Mount: Recess models provide recess mounting holes on both sides of the enclosure. T-Grid Mount: Housing design allows simple drop-in installation between t-grid runs. Safety wires (supplied by others) are required for attachment to building structure. WIRING Connection to an unswitched AC circuit is required by the NEC. Wiring access is provided for by conduit knockouts in the unit housing. LLMPS Series models also provide knockouts in the back of the housing for rear wiring from standard electrical boxes when surface mounting. LOAD COMPATIBILITY LLMPS model s clean, sinusoidal AC output will operate incandescent lamps as well as all common flourescent and LED lamp types. Consult factory for compatibility with all other lamp types. Lighting loads are driven at 100% output for the entire emergency power cycle. This outstanding feature translates into greater occupant egress vision and safety. CODE INFORMATION All models are UL924 Listed and meet NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. Optional T-Grid models are plenum rated. ELECTRICAL SPECIFICATIONS Input Input Voltages: (60Hz) 120 or 277VAC ± 10% Input Frequencies: 60Hz ± 2% Input Protection: Provided by Service Panel, Rated 20A max. Output Output Voltages: (60Hz) 120 or 277VAC Efficiency Rating: 98% at full rated load (line) Waveform: Sinusoidal (digitally controlled) Static Voltage: ± 5% during battery discharge. 0-100% linear load. Output Frequencies: 60 Hz. ± 0.3Hz during emergency cycle Output Distortion: Less than 3% THD (linear load) Transfer Time: Less than 1.0 second Load Power Factor Range: 0.44 Lead to 0.44 Lag Minimum Loading: 0% of rated system capacity Output Protection: Inverter fuse PAGE 2 OF 5

BATTERIES AND CHARGER Battery Battery Types: Sealed Lead-Calcium (10 year life) or Sealed Nickel-Cadmium (15 year life) Battery Voltage: 12VDC for all MPS models Runtime: 90 minutes standard. Other runtimes available, consult factory. Battery Protection: Low Voltage Battery Disconnect protects the battery from being severely damaged by deep discharge during prolonged power failures. DC Overload and Short Circuit Protection provided by a DC input fuse. Charger Charger Fully automatic, temperature compensated, dual-mode charger Power Consumption: 9W max. (All models) Recharge Duty Cycle: Meets UL924 requirements Controls: Momentary test switch, AC-On, Charge-On and Inverter-On LED indicator lights Safety Circuitry: AC Lockout prevents battery discharge prior to initial unit power-up. Brownout Protection automatically switches the unit to emergency mode when utility voltage is significantly reduced. ENVIRONMENTAL Altitude: < 10,000 feet (3,000m) above sea level without derating. Operating Temperature Range: Lead-Calcium Models: 68ºF to 86ºF (20ºC to 30ºC) Nickel-Cadmium Models: 32ºF to 122ºF (0ºC to 50ºC NOTE: Optimum system performance between 20 C (68 F) and 30 C (86 F); temperatures outside of this range will affect battery performance and life. Relative Humidity: 95% non-condensing OPERATION Upon failure of the normal utility power the LLMPS unit is automatically turned on by a solid state switching circuit and provides a minimum of 90 minutes of emergency power to the connected load. Lumen output will be maintained at 100% of the lamp s rating throughout the entire duration. A solid state low voltage disconnect circuit is used to protect the battery from being severely damaged by a deep discharge. When normal utility power is restored, the unit switches the load back to normal utility operation and the fully automatic, temperature compensated, dual mode charger begins to restore the battery; bringing it to full charge within UL924 specified parameters. A brownout sensing circuit insures proper operation during low line conditions. IMPROVED AESTHETICS The LLMPS system s sinusoidal AC output design eliminates voltage drop and proximity concerns. This allows ades flexibility in installation location as LLMPS units can be installed hundreds of feet from the units they power. This means LLMPS units to be located conveniently out of sight in closets or utility rooms without interrupting architectural aesthetics. In lighting applications, no special or additional emergency fixtures are necessary. Simply designate and connect existing lighting fixtures, either interior or exterior, to the MPS unit for emergency operation eliminating the need for exposed, stand-alone emergency luminaires. LLMPS SYSTEM ADVANTAGES Compared to traditional discrete emergency lighting units, the LLMPS Series provides emergency illumination from a single power source resulting in lower maintenance overhead and routine testing expenses. LLMPS units lower installation costs by powering existing lighting fixtures during emergencies. And because connected fixtures are driven at full brilliancy, they provide far superior egress lighting and deliver improved occupant safety. WARRANTY Unit: (excluding lamps) 3-years full coverage against defects in materials and workmanship from date of shipment Lead-Calcium Battery: 3 years full warranty plus an additional 7 years of pro-rata coverage Nickel-Cadmium Battery: 5 years full warranty plus an additional 7 years of pro-rata coverage PAGE 3 OF 5

PAGE 4 OF 5

SUGGESTED SPECIFICATIONS An inverter system with sinusoidal output shall be supplied capable of powering any combination of lighting fixtures, including incandescent, flourescent, induction and/or LED light sources without compatibility problems. The system shall transfer in less than 1.0 second to reliably back up lighting fixtures without loss of illumination and operate any and all connected lighting fixtures at full lumen output during the compete 90 minute discharge cycle. The input voltage shall be the same as the output voltage and shall be single phase (120) (277) volts, 60 Hz. Capacity will be (20 Watts) (32 Watts) (35 Watts)(55 Watts) for a minimum duration of 90 minutes. The design shall be a standby, off-line inverter with online efficiency of 98%; online double conversion UPS systems shall not be considered acceptable alternatives. MPS system output shall be a PWM generated sine wave with less than 3% total harmonic distortion. The system shall also provide short circuit and overload protection as standard. An intuitive three LED display shall provide system operational information at a glance and alert user to any malfunction in system performance. Authorized maintenance personnel shall have access to the system s controls while being protected from any live exposed connections. Protective devices shall include a DC input fuse. AC input overcurrent protection for live circuits to be provided by service panel rated 20A maximum. AC lockout, reverse battery connection, low voltage battery disconnect (LVD), short circuit and overload protection shall be provided standard on all models. The entire LLMPS system, including batteries, shall be provided in compact cabinetry which shall have provisions for (surface)(recessed)(t-grid) mounting. System shall utilize a (sealed lead calcium battery with a 10 year design life)(sealed Nickel-Cadmium battery with a 15 year design life). The charger shall be temperature compensated, dual mode type, and recharge the batteries as per UL 924 guidelines. Entire system shall tested, approved, and labeled to UL924 Emergency Lighting and Power Systems standards. (T-Grid models will be plenum rated). System shall be Best LLMPS series model number:. PAGE 5 OF 5