KAN-therm System. Series 71A, 75A, 51A, 55A manifolds. installation and maintenance instructions

Similar documents
Manifolds series 73A and 77A. Instruction manual

SYSTEM KAN-therm. Underfloor heating. Comfort and efficiency TECHNOLOGY OF SUCCESS ISO 9001

New version of the catalogue has been modified, both from the point of commercial information

MrPEX 1 ½ " Brass Manifold Installation Guide

GTFLOW EXTENSION MANIFOLD ASSEMBLY INSTRUCTIONS

SYSTEM KAN-therm Push Platinum

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide

KAN-therm Inox System technical information, catalogue

Paint/Solvent/Dump Valve and Flow-Through Valve

HEATING SYSTEMS PRICE LIST 07 / 2008 TABLE OF CONTENTS

TCU Flushing Manifold and RTD Installation

MrPEX 1 ¼ Stainless Steel Manifold Installation Guide

INSTALLATION INSTRUCTIONS AOS-R (Air Oil Separator-Return) Turbo Subaru and STi Document# Support:

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

dynacon floor heating manifold with automatic flow control

INSTALLATION & OWNER S MANUAL

Model 3051 Sensor Module Replacement

TR-254 Passive Skimmer and optional TR inch Extension Canister Assembly and Installation Instructions.

Manifold Isolation Valves

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

CHOOSING YOUR MANIFOLD & LOCATION

INSTALLATION INSTRUCTIONS AOS-R (Air Oil Separator-Return) Turbo Subaru and STi Document# Support:

1" QickZone Modular Brass Manifold Installation Instructions Parts List

Instruction Manual For MrPEX Composite Radiant Manifold

INSTALLATION INSTRUCTIONS AOS-R (Air Oil Separator-Return) Turbo Subaru and STi

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

ACCESSORIES & FITTINGS 800 SERIES CONTROL VALVES

LK Manifold RF. Design. Requirements. Documentation

INSTALLATION INSTRUCTIONS Dual Catch Can Kit Subaru Turbo and STi Document# Support:

Components for central heating

Boiler room components 0459EN October 2013 Safety pressure switch with manual reset

KIT # K-3114, K-3115 MOTORCYCLE HANDLEBAR SWITCH PRESSURE GAUGE

Operating manual LPS. Humidifies and Cools. ÁLPS.ENzÈ LPS.EN

Pressure Reducing Valve Type 2114/2415

4/3/2014 Ryobi Electronics Parts Catalog -- Ryobi Power Tools Consumer: [H301PL 3 Gallon Air Compressor (Husky)]/[Figure A]

INSTALLATION INSTRUCTIONS FOR DECK TUB SETS with HAND SHOWER Valves Numbered: &

How to Replace Old Style Control Manifold with New Style Manifold on AS-Series Pumps

Bulk Supply Station. HSAUSA Bulk Supply Station HSAUSA

M9/D (-020 thru -022) M11/D (-020 thru -022)

SYSTEM KAN-therm Push Platinum ISO 9001

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Bulk Supply Station. Collins Ink

Work shop manual. Öhlins Steering damper Road & Track

B21 Series BASOTROL Gas Valve

One-Gun Add-On Kit For Smart-Coat Controllers

215 Gallon Waste Oil Tank With Metering Pump Installation Instructions

Table of Contents Introduction 3 Chapter 2: Operation 4 Chapter 3: Components 5 Chapter 4: Specifications 8

Floor heating manifold with automatic flow control

Inverted High Pressure Fluid Filters

Solenoid Valve Installation Kit

TSI Date Group No. Supp. Page

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

Assembly instructions

MODEL CMA-44 PARTS MANUAL Rev 2.13

Installing an H-200 Integral Right-Angle Module

HV angle valve with single acting pneumatic actuator and closing spring (NC)

Shown on engine 904.9

SINGLE MANIFOLDS TECHNICAL DATA SHEET10/ ENG

HOT WAX & SHINE INSTALLATION MANUAL. G5 & G5s LASERWASH

MECHANICAL CYLINDERS Operating Instructions

INSTALLATION & OWNER S MANUAL

Technical Bulletin. Parts and Service News

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

Composite PEX-AL-PEX Tubing

Spray Pressure Control Manifold

PLUMBING SYSTEMS PIPE & FITTINGS

This kit may void factory warranty please check with manufacturer.

PARTS ORDERING INFORMATION

COMPACT RACK TYPE DISHWASHER

Mounting and operating instructions EB EN. Differential Pressure and Temperature Regulator with Flow Limiter Type 2479/2430 K

1991 Volkswagen Vanagon Syncro

SECTION 6A1-2 - ENGINE MECHANICAL - V6 SUPERCHARGED

Model RM-1 Riser Manifold Commercial and Residential General Description

Catalogue technical information

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

Current parts on a ROTAX 125 MAX DD2 evo

Pro-Swirl Manifold Air Heater

Spray Pressure Control Manifold

FCU Floor Control Unit

MFR35MCATS : 01 - CONTROL PANEL (MC) [1/25] Ref # Part Number Qty. Description PLATE, BACK-UP (COIN METER) PANEL, CONTROL 3

JARVIS. Model HTC -80 Hog Toe Cutter

Repair Parts List WASHER MODEL NUMBER MFR35MCATS. When requesting service or ordering parts, always provide the following information:

READ INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Table of contents. Introduction 2. Instrumentation 4. Servicing your vehicle 5

TRAILER MOUNTED PUMP MODEL B50 DRIVE CYLINDER CIRCUIT HYDRAULIC COMPONENTS & SCHEMATIC

1997 Volvo 850 GLT. Fig. 2: Removing Drive Shaft, Engine Mount Bolt & Torque Arm (5-Cylinder) Courtesy of VOLVO CARS OF NORTH AMERICA.

364 EDWARD STREET WAGGA WAGGA NSW 2650 PHONE FAX

Features. HTHP Filter Press for Drilling Fluid Testing DRILLING FLUIDS EQUIPMENT

Model 4070 Center Post Tire Changer

FLP-2492/KLP-4492 Impeller Flowmeter

2311FA. Pressure Tester USER INSTRUCTION MANUAL BARFIELD M/N 2311FA Revision C April 12, 2011 BARFIELD, INC. Corporate Headquarters

LK Manifold RF. Design. Requirements

Spare parts list. Hydraulic Power Pack PAC P 18. Chicago Pneumatic Construction Tools

Repair Parts List WASHER MODEL NUMBER MFR35PCAVS. When requesting service or ordering parts, always provide the following information:

OM Field-Type I/P Converter Model : KUX113 User's Manual

Lube Level Maintainer

BD TrackMaster S D o d g e H P C R Installation Instructions

System Components. Potable water Distributors, wall boxes and connections

Special tools required:

Transcription:

instrukcja_rozdzielacz71a-55a_pl_ru_en:print 2010-09-30 14:14 Strona 25 KAN-therm System Series 71A, 75A, 51A, 55A manifolds installation and maintenance instructions Series 71A and 75A manifolds Installation and maintenance instructions......... 26 Series 71A and 75A manifold description......................................... 26 Series 71A and 75A manifold operation........................................... 27 Control valves adjustment in manifold lower beam - series 71A........................ 27 Flowmeters adjustment in manifold lower beam - series 75A.......................... 29 Valve actuators in manifold upper beam installation and start-up....................... 29 Connecting thermostats and actuators............................................ 30 Series 51A and 55A manifolds Installation and maintenance instructions......... 31 Series 51A and 55A manifold................................................... 31 Series 51A and 55A manifold operation........................................... 32 Installation of typical elements in manifolds................................ 33 2010 Copyright KAN Sp z o.o. All rights reserved. Copyrights include texts, pictures and their lay-out in KAN Sp z o.o. publications.

instrukcja_rozdzielacz71a-55a_pl_ru_en:print 2010-09-30 14:14 Strona 26 Series 71A and 75A manifolds Installation and maintenance instructions Fig.1 Series 71A manifold 1. electric actuator cut-off valve 2. control valve 3. output for particular circuits from GZ¾" Fig.2 Series 75A manifold 1. electric actuator cut-off valve 2. flowmeter 3. output for particular circuits from GZ¾" KAN-therm System series 71A and 75A manifolds are designed to control floor heating system. They enable to control temperature in a heated room by means of room thermostat controlling electric actuators fixed on the manifold upper beam. Particular floor heating loops are connected to the manifold using screw joints for PE-RT, PE-Xc pipes or screw joints and connecting pipes for PE-RT/Al/PE-HD pipes. Connections of that type are self-sealing (do not use additional seals, e.g. tow or teflon tape). Series 71A and 75A manifold description The manifold is consisting of: 1. female thread 1" on feeding and return connections, 2. upper beam with built-in electric actuator cut-off valves (actuator installation on valves using M28 1,5mm adapter - red) and outputs for particular circuits with male thread G¾" (Eurokonus). Notice that electric actuators are not included in manifold sets. 3. series 71A (Fig.1) - lower beam with built-in control valves (they compensate flow resistance in particular heating coil) and outputs for particular circuits with male thread G¾" (Eurokonus); series 75A (Fig.2) - lower beam with built-in flowmeters (they compensate flow resistance in each heating coil and indicate real water flow) and outputs for particular circuits with male thread G¾" (Eurokonus). 26 www.kan.com.pl

instrukcja_rozdzielacz71a-55a_pl_ru_en:print 2010-09-30 14:14 Strona 27 Note: From one side the manifold is connected to the system (upper beam - feeding, lower beam - return), from the other side the upper and lower beams have to be equipped with plugs, optionally reduction and/or a vent (see Chapter 3 "Installation of typical elements in manifolds"). Plugs, reductions, etc. are additional elements and are not included in standard manifold sets. Series 71A and 75A manifold operation 1. The manifold is fed by heating medium from the system at a maximum temperature (T max) 55 C. Connect floor heating system feeding to the manifold upper beam. 2. From the upper beam, through particular loops, the medium gets to the floor heater. Each heating loop has a cut-off valve connected with electric actuator. 3. The heating medium returning from heating loops is directed to the manifold lower beam from where it gets back to the system. Flow resistance compensation in particular loops takes place by adjusting valves on the lower beam (see "valve adjustment on manifold lower beam - series 71A and 75A"). 4. Floor heating temperature adjustment consists in actuator closing the valve on manifold at the moment of having reached desired temperature in a heated room - no flow in floor heating coil (the temperature is adjusted manually by means of room thermostat). Make sure the manifold is correctly connected to the system. Fix the manifold between feed and return pipes in low temperature circuit (T max 55 C). Connect the upper beam to feed, and the lower beam to return line. Control valves adjustment in manifold lower beam - series 71A 1. Unscrew safety element using Allen key 6 mm - Fig.3. 2. Adjust valve head using Allen key 5 mm by closing the valve completely (torque 6 Nm) and then turn to open. The number of turns corresponds with the design setting number - Fig. 4, 3. After adjustment drive safeguarding element using Allen key 6 mm. Fig. 3. Fig. 4. Valve characteristics are presented in Fig. 5. kan@kan.com.pl 27

instrukcja_rozdzielacz71a-55a_pl_ru_en:print 2010-09-30 14:14 Strona 28 Fig.5. Valve characteristics in manifold lower beam 28 www.kan.com.pl

instrukcja_rozdzielacz71a-55a_pl_ru_en:print 2010-09-30 14:14 Strona 29 Flowmeters adjustment in manifold lower beam - series 75A 1. Take off plastic cover (fixed by "snap fastener") - Fig. 6. 2. By turning the flowmeter adjust to the required flow on the scale (in accordance with the design) - Fig. 7. 3. After adjusting the flow put on safeguard against accidental re-adjustment. Fig. 6 Fig. 7 Valve actuators in manifold upper beam installation and start-up 1. Turn off the manual adjustment cap (Fig.8). 2. Put room data label on the valve (the label is on actuator packaging). 3. Screw on actuator adapter M28 1,5 - red (Fig.9). 4. Fix actuator on the adapter and turn at desired angle (Fig.10). 5. Calibrate actuator: a) connect actuator to the power supply for approx. 6 min. (actuator and manifold circuit will open to the max) b) disconnect actuator from the power supply and wait for approx. 6 min. (actuator and manifold circuit will close) c) actuator is calibrated and ready to operate. Fig. 8 Fig. 9 Fig. 10 Actuators are available in two versions: 24V (K-600701) and 230V (K-600700). Actuator operates in NC mode (normally open). In order to ensure correct operation of manifold system, connect actuator to the mains (230V or 24V) according to appropriate diagram (see connecting electric actuator to room thermostat diagram - Fig.11 and 12). To facilitate the start-up of the whole system, actuators have "first open" mode which makes them open before connecting them to the mains for the first time. More details in actuators instruction manual. kan@kan.com.pl 29

instrukcja_rozdzielacz71a-55a_pl_ru_en:print 2010-09-30 14:14 Strona 30 Connecting thermostats and actuators 1. It is possible to connect up to 10 actuators to one thermostat. 2. Electric actuator operates with: a) room bimetallic thermostat 230V (0.6106, 0.6107) - connection diagram Fig.11 b) electronic thermostat with diode 230V (K-800100) - connection diagram Fig. 12 c) electronic thermostat with diode 24V (K-800101) - connection diagram Fig.12. Fig.11. Connection diagram of bimetallic thermostat with electric actuator. Fig.12. Connection diagram of electronic thermostat with electric actuator. Notice: All works connected with electrical system should be performed by qualified and authorized personnel. More details in room thermostats instruction manual. 30 www.kan.com.pl

instrukcja_rozdzielacz71a-55a_pl_ru_en:print 2010-09-30 14:14 Strona 31 Series 51A and 55A manifolds Installation and maintenance instructions Fig.14. Manifold series 51A 1. control valve 2. output for particular circuits - GZ¾" 3. opening G½" for a vent Fig.15. Manifold series 55A 1. flowmeter 2. output for particular circuits - GZ¾" 3. opening G½" for a vent KAN-therm System manifolds series 51A and 55A are designed for floor heating system adjustment. Each floor heating loop is connected to the manifold using screw joints for PE-RT, PE-Xc pipes or screw joints and connecting pipes for PE-RT/Al/PE-HD pipes. Connections of that type are self-sealing (do not use additional seals, e.g. tow or teflon tape). Series 51A and 55A manifold The manifold is consisting of: 1. on feed and return pipes - female thread 1" 2. upper beam with outputs for particular circuits with male thread G¾" (Eurokonus) and opening G½" for a vent. 3. series 51A (Fig.14) - lower beam with built-in control valves (they compensate flow resistance in particular coil pipes) and outputs for particular circuits with male thread G¾" (Eurokonus); series 55A (Fig.15) - lower beam with built-in flowmeters (they compensate flow resistance in each coil pipe and indicate real water flow) and outputs for particular circuits with male thread G¾" (Eurokonus). Note: From one side the manifold is connected to the system (upper beam - feed, lower beam - return) but from the other side the upper and lower beams have to be equipped with plugs, optionally reduction and/or a vent (see Chapter 3 "Installation of typical elements in manifolds"). Plugs, reductions, etc. are additional elements and are not included in standard manifold sets. kan@kan.com.pl 31

instrukcja_rozdzielacz71a-55a_pl_ru_en:print 2010-09-30 14:14 Strona 32 Series 51A and 55A manifold operation 1. The manifold is fed by heating medium from the low temperature system at a maximum temperature (T max 55 C). Connect floor heating system feeding to the manifold upper beam. 2. From the upper beam, through particular loops, the medium gets to the floor heater. 3. The heating medium returning from heating loops is directed to the manifold lower beam from where it gets back to the system. Leveling resistance of flow in particular loops takes place by adjusting valves on the lower beam (see "valve adjustment on manifold lower beam - series 71A and 75A"). Make sure the manifold is correctly connected to the system. Fix the manifold between feed and return line in low temperature circuit (T max 55 C). Connect the upper beam to feed, and the lower beam to return line. Note: Adjust control valves (series 51A) or flowmeters (series 55A) in manifold lower beam similarly to series 71A and 75A manifolds. 32 www.kan.com.pl

instrukcja_rozdzielacz71a-55a_pl_ru_en:print 2010-09-30 14:14 Strona 33 Installation of typical elements in manifolds All typical elements shown below have their own O-Rings and no additional seals should be applied, e.g. tow or teflon tape (with the exception of automatic vent with foot valve). Manifold 51A, 55A, 71A, 75A with plug G1" (6096.43). Manifold 51A, 55A, 71A, 75A with reduction G1" G" (4.13). Manifold 51A, 55A, 71A, 75A with reduction G1" G½" (4.12). Manifold 51A, 55A with plug G1" (6096.43) and drain-vent valve (1305.11). Manifold 51A, 55A with plug G1" (6096.43) and manual vent (5322). Manifold 51A, 55A with plug G1" (6096.43) and automatic vent with foot valve (0.52071). Note that automatic vent with foot valve (0.52071) does not have an O-Ring. In order to seal the connection, use teflon tape or tow. Manifold 51A, 55A, 71A, 75A with reduction G1" G½" (4.12) and drainvent valve (1305.11). Manifold 51A, 55A, 71A, 75A with automatic vent and drain valve (R5541). Manifold 51A, 55A, 71A, 75A with tee connection (R542), cap G½" (6095.34) and manual vent (5322). kan@kan.com.pl 33

instrukcja_rozdzielacz71a-55a_pl_ru_en:print 2010-09-30 14:14 Strona 34 Manifold 51A, 55A, 71A, 75A with tee connection (R542), cap G½" (6095.34) and drain-vent valve (1305.11). Manifold 51A, 55A, 71A, 75A with tee connection (R542), cap G½" (6095.34) and automatic vent with foot valve (0.52071). Note that automatic vent with foot valve (0.52071) does not have an O-Ring. In order to seal the connection, use teflon tape or tow. Manifold 71A and 75A upper beam with extension equipped with actuator valve (712) and cap G1" (6096.43). The element connected to the manifold by means of nipple G1" with special seal (R543). Manifold 71A and 51A lower beam with extension equipped with control valve (512) and cap G1" (6096.43). The element connected to the manifold by means of nipple G1" with special seal (R543). Manifold 75A and 55A lower beam with extension equipped with flowmeter (752) and cap G1" (6096.43). The element connected to the manifold by means of nipple G1" with special seal (R543). Manifold 71A and 75A upper beam with extension consisting of tee connection (R542), cap G½" (6095.34) and nipple G½" G" (P05). 34 www.kan.com.pl

instrukcja_rozdzielacz71a-55a_pl_ru_en:print 2010-09-30 14:14 Strona 35 Manifold 71A with extension set. Manifold 75A with extension set. Manifold 51A with extension set. Manifold 55A with extension set. Note that nipples used to connect extensions to manifolds are not included in manifold sets. kan@kan.com.pl 35

instrukcja_rozdzielacz71a-55a_pl_ru_en:print 2010-09-30 14:14 Strona 36 Manifold 51A, 55A, 71A, 75A upper and lower beam with straight set (K-600400). Note that sets are available in kits (upper + lower). Manifold 51A, 55A, 71A, 75A upper beam with angle set (K-600500). Note that sets are available in kits (upper + lower). Manifold 51A, 55A, 71A, 75A lower beam with angle set (K-600500). Note that sets are available in kits (upper + lower). Manifold 51A, 55A, 71A, 75A with angle set kit. 36 www.kan.com.pl