Varius SUMMARY OF MODELS

Similar documents
Varius SUMMARY OF MODELS

Fuse switch-disconnectors

Fuse switch-disconnectors

Varius SUMMARY OF MODELS

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K

Varius SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS. Type SPB S3PB SPF SP4.. SP50

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

Overcurrent releases - description, specifications, characteristics specifications specifications description...

MOULDED CASE CIRCUIT BREAKERS BC160N

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE

vertical fuse switch disconnectors

Fuse switch disconnectors

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S

Fuse switch disconnectors

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Devices for switching and control

Modeion MOULDED CASE CIRCUIT BREAKERS BL1600S


MOULDED CASE CIRCUIT BREAKERS BC160N

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

3VT Kompaktleistungsschalter bis 630A

Horizontal fuse disconnects

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Motorized switch-disconnectors OTM 40 to 125 Amperes

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka)

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

MULTIVERT 250A Size 1, 690VAC

MOULDED CASE CIRCUIT BREAKERS BL1600S

LV HRC fuse switch-disconnectors

MS25, MST25, MS20, MST20

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka)

Special Purpose Fuses

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Residual current circuit breakers with conditional shortcircuit

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

switch disconnectors switch disconnectors fuses

3NP1 Fuse Switch Disconnectors up to 630 A

Vertical fuse disconnects

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC

Switch-disconnectors OT , OETL 3150

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Euroload Changeover Switch

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

max pole for t=15 ms

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

BETA Switching Switches and Light Indicators

K50H004UP cam changeover switch - 4-pole A - screw mounting

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

MULTIVERT 1000A Main Incomer, 690VAC

Breakers and Switches. Switches Switch-disconnectors OT and OTM

K30H001YP cam star-delta switch - 3-pole A - screw mounting

Cylindrical fuse-link

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

SENTRON Switching and Protection Devices Switch Disconnectors

FUSE BASES NH FUSE BASES 690V 160A 160A

Selective main circuit breakers S 750 series Technical Data

LINOCUR Size D02 63A 230VAC/440VAC

Crimpmate Range pitch 5.00

Breakers and Switches. Switches Change-over and transfer switches

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

D509E. Manual Motor - Starters

Low voltage moulded case circuit breaker EB2

Vertical fuse disconnects

PANEL PANEL MOUNTING COMPONENTS

25A 25A 32A 40A 40A 63A 63A 80A

Vistop TM isolating switches 63 to 160A

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand

IEC Low Voltage General Purpose Protection

NH-Fuse system Low voltage

Technical Data Accessories MCBs Ex9B.

Switches. Fused Switches ITCP for Semiconductor Fuses 32 to 800A CONTROL: FUSE CONNECTING: SWITCHING: MECHANISM: FIXING: CONSTRUCTION:

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector

PROTECTION AND CONNECTION. ABB Compact ATS Compact without compromise

Low Voltage Switches. Switches Motorized change-over switches OTM _C

Wall mounted switchgear

Miniature circuit-breaker (MCB) SH200M Series

Electronic circuit breaker EBU10-T

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Transcription:

SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00 2 4a Fuse-link size 000 000/00 2 4a Utilization category at AC 400 V AC-2B AC-2B AC-2B AC-2B AC-2B AC-22B Accessories Remote signallings of cover position OD-FH-SK EMV-LTL4a Connecting sets CS-FH000-..., Nx0-FH000 CS-FH00-... CS-FH2-..., CS-FH2-... CS-FH2-..., CS-FH2-..., CS -FH2-... CS-FH-..., CS-FH2-... - Interconnecting busbars CS-FH000-L. CS-FH000-L. - - - - Adapters for busbar systems with spacing 60mm OD-FH000-AL60 OD-FH00-AL60 OD-FH-AL60 OD-FH2-AL60 OD-FH-AL60 - Assembly kits for 2-pole, 4-pole OD-FH000-SS24 OD-FH00-SS24 OD-FH2-SS24 - Connecting space covers OD-FH000-KPA OD-FH00-KP. OD-FH-KP. OD-FH2-KP. OD-FH-KP. - Barriers OD-FH000-Z. OD-FH00-Z OD-FH-Z OD-FH2-Z OD-FH-Z - Locking inserts OD-FH000-VU - OD-FH2-VU - Front shields OD-FH000-KR OD-FH00-KR OD-FH-KR OD-FH2-KR OD-FH-KR - C2

SUMMARY OF MODELS Description Connecting sets Barrier against accident contact Accessory for disconnector FH000 For connection of CU/AL conductor of cross-section To increase the safety of personnel in handling switch- Locking insert For locking the switch-disconnector cover. -disconnector. up to 95 mm2. Connecting space covers For additional covering of connecting space. Remote signalling of cover position Indicates closed state. Cable length m. For connection of Cu conductors/pole of cross-section 0 mm2. Adapter for busbar system with spacing 60 mm Busbar spacing 60 mm. Busbar thickness 5 2 mm. Busbar width 2 2 mm. Cable outlet bottom or top. Accessory for switch-disconnector FH00 For connection of Cu/Al conductor of cross-section up to 95 mm2. Accessory for switch-disconnector FH, FH2 and FH For connection of Cu/Al conductor of cross- -section up to 50 mm2 for FH and FH2, up to 00 mm2 for FH. Remote signalling of fuse-link state Enables remote signalling of fuse-link in fuse switch-disconnector. Assembly kit For assembling 2-pole or 4-pole. Interconnecting busbar Accessory for switch-disconnector FH000 and FH00. For connection from 2 up to 5 pcs. -pole switch- -disconnectors. Front shield Additional covering of free space around the fuse switch-disconnector. C

FH, FH2, FH FUSE SWITCH-DISCONNECTORS FH, FH2, FH are intended for fuse-links with blade contacts. Enable safe disconnection not only of rated current, but also overcurrent up to octuple rated current. Variability of connecting sets. Measuring holes in the cover. It is possible to lock the switch-disconnector cover. It is equipped with a label for description of the protected circuit. Mounting directly on the panel by means of screws. On busbars with spacing 60 mm by means of adapter. More switch-disconnectors side-by-side or flat can be installed without limitation of electrical parameters. FH connection with terminal screws M0/20 Nm for cable lugs max. 4 mm and busbars of width max. 25 mm. FH2 connection with terminal screws M0/20 Nm for cable lugs max. 40 mm and busbars of width max. 0 mm. FH connection with terminal screws M2/28 Nm for cable lugs max. 44 mm and busbars of width max. 40 mm. Connecting sets with terminal inbus screws. Connection Bottom connection is possible without limitation of electric parameters (the device should be marked ATTENTION, BOTTOM CONNECTION ). In [A] 250 400 60 Number of poles FH-A/F FH-A/F FH2-A/F FH2-A/F FH-A/F FH-A/F Order code OEZ:462 OEZ:464 OEZ:469 OEZ:468 OEZ:474 OEZ:47 Weight [kg].64 2.786.280 2.980.70 4.992 Package [pcs] Weight [kg].60 2.800.292 2.995.722 4.295 Package [pcs] Weight [kg] 2.750 2.990 5.08 Package [pcs] with remote signalling with cable Includes a connector with a m cable. In [A] 250 400 60 Number of poles FH-S/F FH-S/F FH2-S/F FH2-S/F FH-S/F FH-S/F Order code OEZ:46 OEZ:465 OEZ:47 OEZ:470 OEZ:476 OEZ:475 with remote signalling without cable Includes a connector without cable. In [A] 250 400 60 Number of poles FH-SB/F FH2-SB/F FH-SB/F with light indication By means of LED in each pole separately. In [A] 250 400 60 Number of poles FH-L/F FH2-L/F FH-L/F Order code OEZ:467 OEZ:472 OEZ:477 The red LED is flashing in case of fuse-link blowing. Order code OEZ:20769 OEZ:20770 OEZ:2077 Weight [kg] 2.700.2 4.455 Package [pcs] Accessories Connecting sets Adapters Assembly kit Locking insert Remote signalling of cover position Connecting space covers Front shield Barriers Spare parts C20 CS-.. OD-..-AL60 OD-FH2-SS24 OD-FH2-VU OD-FH-SK OD-..-KP. OD-..-KR OD-..-Z ND-.. page C27 page C0

FH, FH2, FH FUSE SWITCH-DISCONNECTORS FH, FH2, FH Specifications FH FH2 FH Standards IEC 60947- IEC 60947- IEC 60947- IEC 60947- IEC 60947- IEC 60947- EN 60947- EN 60947- EN 60947- EN 60947- EN 60947- EN 60947- Approval marks Rated operating current I e 250 A 400 A 60 A Rated operating voltage U e AC/DC 690 V AC/DC 690 V AC/DC 690 V (AC/DC 400 V / FH-L/.) (AC/DC 400 V / FH2-L/.) (AC/DC 400 V / FH-L/.) Utilization category ) FH.-./. AC 400 V AC-2B AC-2B AC-2B AC 500 V AC-22B AC-22B AC-22B AC 690 V AC-2B AC-22B AC-22B DC 250 V DC-2B DC-2B DC-2B DC 440V DC-2B / 60 A DC-2B / 250 A DC-2B / 5 A FH.-./. AC 400 V AC-2B AC-2B AC-2B AC 500 V AC-22B AC-2B AC-2B AC 690 V AC-22B AC-22B AC-22B two-pole connection DC 440 V DC-2B DC-2B DC-2B Rated thermal current with fuse-link I th 250 A 400 A 60 A Rated thermal current with disconnecting link I th 25 A 520 A 750 A ZP in FH, ZP2 in FH2, ZP in FH 000 A / ZP/000 Rated frequency f n 40 60 Hz 40 60 Hz 40 60 Hz Rated insulation voltage U i AC 000 V AC 000 V AC 000 V Rated conditional short-circuit current (RMS) I cc AC 400 V 20 ka / 250 A 20 ka / 400 A 20 ka / 60 A AC 500 V 50 ka / 250 A 50 ka / 400 A 50 ka / 60 A AC 690 V 25 ka / 250 A 25 ka / 400 A 25 ka / 60 A Rated impulse withstand voltage U imp 2 kv / FH-.A/. 2 kv / FH2-.A/. 2 kv / FH-.A/. 8 kv / FH-.S/. 8 kv / FH2-.S/. 6 kv / FH-.S/. 2 kv / FH-L/. 2 kv / FH2-L/. 2 kv / FH-L/. Rated short-time withstand current I cw s 5 ka 5 ka 20 ka Fuse-link size 2 Max. power losses of the fuse-link P v 2 W 4 W 48 W Power losses at I n without fuse-link P z 9 W 2 W 49 W Overvoltage category for AC 690 V IV IV IV Connection Connecting screw M0 M0 M2 Torque 20 Nm 20 Nm 28 Nm Remote signalling Max. voltage/current U max /I max AC 250 V / 5 A AC 250 V / 5 A AC 250 V / 5 A DC 250 V / 0.2 A DC 250 V / 0.2 A DC 250 V / 0.2 A Light indication Rated voltage U n AC 24 400 V AC 24 400 V AC 24 400 V DC 24 450 V DC 24 450 V DC 24 450 V Fuse-link is blown red LED is blinking red LED is blinking red LED is blinking Operating conditions Electrical endurance operating cycles 200 at 250 A 200 at 400 A 200 at 60 A Mechanical endurance operating cycles 400 800 800 Degree of protection from front side, built-in device, cover closed IP0 IP0 IP0 (without measuring holes broken off) Degree of protection from front side, built-in device, cover opened or removed IP20 IP20 IP20 Operating ambient temperature -25 +55 C -25 +55 C -25 +55 C Working position see page I see page I see page I Max. sea level 2 000 m 2 000 m 2 000 m Pollution degree Seismic resistance according to VE ŠKODA 0.25 50 Hz / g 0.25 50 Hz / g 0.25 50 Hz / g ) In case of use disconnecting links ZP in FH, ZP2 in FH2 and ZP in FH switch-disconnector, the utilization category is decreased by one degree C2

FH, FH2, FH FUSE SWITCH-DISCONNECTORS FH, FH2, FH Dimensions FH FH-A/F FH-A/F and FH-L/F 86 4 67 * 20 08 *** 8 20 44 266 266 4 8 4 5 24 24 44 4 4 5 7 25 86 25 58 58 FH-A/F, FH-A/F and FH-L/F 24 OD-FH-KP. 67 * 8 20 266 *** 20 67 OD-FH-KP. 67 * for FH-A/F= 78 ** for FH-A/F= 6 *** for FH-A/F=27 5 ** FH-... + OD-FH-AL60 FH-S/F and FH-S/F 67 62 28 4 56 * for FH-S/F= 78 ** for FH-S/F= 6 *** for FH-S/F= 8 5 ** C22

FUSE SWITCH-DISCONNECTORS FH, FH2, FH Dimensions FH2 FH2-A/F FH, FH2, FH FH2-A/F and FH2-L/F FH2-... + OD-FH2-AL60 200 56 67 o * 4 *** 98 286 40 24 5 24 7 7 5 49 49 98 286 79 0 4 2 0 66 66 FH2-, FH2-A/F OD-FH-KP. 8 FH2-A/F and FH2-L/F * for FH2-A/F= 78 ** for FH2-A/F= 50 *** for FH2-A/F=299 67 * 98 292 *** 8 OD-FH-KP. 8 47 ** FH2-S/F and FH2-S/F * for FH2-S/F= 78 ** for FH2-S/F= 50 *** for FH2-S/F=44 62 42 55 70 8 47 ** C2

FH, FH2, FH FUSE SWITCH-DISCONNECTORS FH, FH2, FH Dimensions FH FH-A/F FH-A/F and FH-L/F 46 286 44 56 46 286 44 4 80 4 56 80 9 40 257 40 82 82 FH-A/F, FH-A/F and FH-L/F OD-FH-KP. 52 7 * * for FH-A/F= 78 ** for FH-A/F= 58 *** for FH-A/F=04 46 0 *** 95 OD-FH-KP. 59 ** FH-... + OD-FH-AL60 FH-S/F and FH-S/F 24 7 7 * * for FH-S/F= 78 ** for FH-S/F= 58 *** for FH-S/F=49 45*** 62 56 69 84 95 59** C24

FUSE SWITCH-DISCONNECTORS FH, FH2, FH Dimensions FH, FH2, FH Clearance and drilling diagrams FH -pole 7 2-pole 42 86 -pole, 4-pole 257 20 0 25 20 0 25 90 50 20 0 25 20.5 0 20.5 0 4 6 4 56 0 FH2 -pole 79 2-pole 58 2 -pole, 4-pole 292 6 25 6 25 0 50 6 25 24.5 0 24.5 0 49 0 4.5 0 66 0 FH -pole 2-pole -pole, 4-pole 9 86 257 50 6 25 6 25 0 50 6 25.5 0.5 0 6 0 48.5 60 80 0 C25

FH, FH2, FH FUSE SWITCH-DISCONNECTORS FH, FH2, FH Diagram FH-.. FH2-.. FH-.. 2x FH-.. 2x FH2-.. 2x FH-.. 2x FH-.. 2x FH2-.. 2x FH-.. FH-.. FH2-.. FH-.. FH-.. + FH-.. FH2-.. + FH2-.. FH-.. + FH-.. FH-.. + FH-.. FH2-.. + FH2-.. FH-.. + FH-.. 5 5 5 7 2 2 4 2 4 2 4 6 2 4 6 4 2 4 6 8 2-pole connection of -pole fuse switch-disconnector for DC application, see Utilization category + -pole connection of two -pole fuse switch-disconnectors for DC applications, see Utilization category + - - Remote signalling of fuse state in -pole fuse switch-disconnector State of contacts with not blown fuse: contacts closed Remote signalling of fuse state in -pole fuse switch-disconnector State of contacts with not blown fuse: contacts 7, 2 8, - 9 closed Remote signalling of cover position of -pole and -pole switch-disconnectors State of contacts with open cover: contacts C NC closed (yellow) (blue) (white) C26

FH, FH2, FH ACCESSORIES FOR FH, FH2, FH For FH, FH2 Connecting sets up to 6 mm 2 Torque 4,5 Nm. Order Description Cross-section Weight Package CS-FH2-SM OEZ:584 clip terminal, pcs Cu 6 6 mm 2 0.066 CS-FH2-SM OEZ:585 clip terminal, pcs Cu 6 6 mm 2 0.200 Connecting sets up to 50 mm 2 Torque 4,5 Nm. Order Description Cross-section Weight Package CS-FH2-S OEZ:559 clip terminal, pcs Cu 25 50 mm 2 0.07 CS-FH2-S OEZ:8226 clip terminal, pcs Cu 25 50 mm 2 0.220 CS-FH2-P OEZ:5592 prismatic clamp, pcs Cu/Al 70 50 mm 2 0. CS-FH2-P OEZ:8227 prismatic clamp, pcs Cu/Al 70 50 mm 2 0.400 Double prismatic looping sets Torque 4,5 Nm. Order Description Cross-section Weight Package CS-FH2-P2 OEZ:559 pcs Cu/Al 2x (70 95) mm 2 0.9 CS-FH2-P2 OEZ:8228 pcs Cu/Al 2x (70 95) mm 2 0.580 For FH2 Connecting sets up to 240 mm 2 Torque 0 Nm. Order Description Cross-section Weight Package CS-FH2-S OEZ:5595 clip terminal, pcs Cu 25 240 mm 2 0.080 CS-FH2-S OEZ:58 clip terminal, pcs Cu 25 240 mm 2 0.240 CS-FH2-P OEZ:5595 prismatic clamp, pcs Cu/Al 6 240 mm 2 0.40 CS-FH2-P OEZ:58 prismatic clamp, pcs Cu/Al 6 240 mm 2 0.420 Double prismatic looping sets Torque 4,5 Nm. Order Description Cross-section Weight Package CS-FH2-P2 OEZ:5597 pcs Cu/Al 2x (20 50) mm 2 0.9 CS-FH2-P2 OEZ:58 pcs Cu/Al 2x (20 50) mm 2 0.580 C27

FH, FH2, FH ACCESSORIES FOR FH, FH2, FH For FH Connecting sets up to 00 mm 2 Torque 0 Nm. Order Description Cross-section Weight Package CS-FH-P OEZ:5800 clip terminal, pcs Cu/Al 20 00 mm 2 0.45 CS-FH-P OEZ:484 clip terminal, pcs Cu/Al 20 00 mm 2 0.45 Double prismatic looping sets Torque 0 Nm. Order Description Cross-section Weight Package CS-FH-P2 OEZ:580 pcs Cu/Al 2x (20 240) mm 2 0.205 CS-FH-P2 OEZ:485 pcs Cu/Al 2x (20 240) mm 2 0.65 For FH, FH2 and FH Terminals for rear connection Torque 20 Nm. Order Description Weight Package CS-FH2-Z OEZ:5594 pcs 0.7 CS-FH2-Z OEZ:8229 pcs 0.520 C28

FH, FH2, FH ACCESSORIES FOR FH, FH2, FH Adapters for busbar systems Busbar spacing 60 mm. Cable outlet bottom or top. Busbar thickness 5 2 mm. Busbar width 2 2 mm. Order Accessory for Weight Package OD-FH-AL60 OEZ:7270 FH-...69 OD-FH2-AL60 OEZ:482 FH2-...50 OD-FH-AL60 OEZ:9557 FH-...600 Assembly kit For assembling 2-pole or 4-pole. 2-pole unit is assembled by means of two FH.-... 4-pole unit is assembled by means of one FH.-... and one FH.-... Order Accessory for Weight Package OD-FH2-SS24 OEZ:7266 FH, 2, 0.060 Locking insert For locking the switch-disconnector cover. Max. diameter of the padlock suspension loop is 4.5 mm. The padlock is not included in the delivery. Order Accessory for Weight Package OD-FH2-VU OEZ:820 FH, 2, 0.006 Remote signalling of cover position Indicates closed state. Cable length m. Possibility of mounting up to 2 microswitches per one switch-disconnector. Order Accessory for Weight Package OD-FH-SK OEZ:2929 FH, 2, 0.0 Technical information see page C26 Connecting space covers for adapter Identical for both upper and lower space. For additional covering of connecting space. Order Accessory for Weight Package OD-FH-KP OEZ:7269 FH-.. 0.08 OD-FH-KP OEZ:7268 FH-.. 0.45 OD-FH2-KP OEZ:48 FH2-.. 0.50 OD-FH2-KP OEZ:480 FH2-.. 0.58 OD-FH-KP OEZ:488 FH-.. 0.075 OD-FH-KP OEZ:487 FH-.. 0.20 Front shields Additional covering of free space around the fuse switch-disconnector. Order Accessory for Weight Package OD-FH-KR OEZ:7267 FH-.. 0.06 OD-FH2-KR OEZ:479 FH2-.. 0.06 OD-FH-KR OEZ:486 FH-.. 0.06 Barriers against accident contact Increase the safety of personnel in handling fuse-links. Order Accessory for Weight Package OD-FH-Z OEZ:727 FH-.. 0.045 OD-FH2-Z OEZ:48 FH2-.. 0.045 OD-FH-Z OEZ:490 FH-.. 0.045 C29

FH, FH2, FH ACCESSORIES FOR FH, FH2, FH Spare parts For FH Description Order Weight Package Cover without signalling of fuse state, -pole, size ND-FH-V OEZ:724 0.260 Cover without signalling of fuse state, -pole, size ND-FH-V OEZ:72 0.64 Cover with signalling of fuse state, -pole, includes a cable with connector ND-FH-VS OEZ:8682 0.276 Cover with signalling of fuse state, -pole, includes a cable with connector ND-FH-VS OEZ:868 0.649 Cover with light indication of fuse state, -pole ND-FH-VL OEZ:5 0.690 For FH2 Description Order Weight Package Cover without signalling of fuse state, -pole, size 2 ND-FH2-V OEZ:726 0.29 Cover without signalling of fuse state, -pole, size 2 ND-FH2-V OEZ:725 0.729 Cover with signalling of fuse state, -pole, includes a cable with connector ND-FH2-VS OEZ:8684 0.07 Cover with signalling of fuse state, -pole, includes a cable with connector ND-FH2-VS OEZ:8685 0.764 Cover with light indication of fuse state, -pole ND-FH2-VL OEZ:52 0.805 For FH Description Order Weight Package Cover without signalling of fuse state, -pole, size 2 ND-FH-V OEZ:728 0.42 Cover without signalling of fuse state, -pole, size 2 ND-FH-V OEZ:727.80 Cover with signalling of fuse state, -pole, includes a cable with connector ND-FH-VS OEZ:8686 0.58 Cover with signalling of fuse state, -pole, includes a cable with connector ND-FH-VS OEZ:8687 0.967 Cover with light indication of fuse state, -pole ND-FH-VL OEZ:5.008 For FH, FH2, FH Description Connector for -pole switch-disconnector with remote signalling of fuse state, without cable, with pins Connector for -pole switch-disconnector with remote signalling of fuse state, with -core cable Connector for -pole switch-disconnector with remote signalling of fuse state, without cable, with 9 pins Connector for -pole switch-disconnector with remote signalling of fuse state, with 9-core cable Order code Weight [kg] Package [pcs] ND-FH-SZ0 OEZ:59 0.028 ND-FH-SZ OEZ:520 0.045 ND-FH-SZ0 OEZ:52 0.08 ND-FH-SZ9 OEZ:522 0.055 C0