Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

Similar documents
Emergency lighting units EM series. EM BASIC lp-2, V BASIC version. Technical data. Ordering data. Article number

Emergency lighting units EM Inverter

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

Emergency lighting units PC COMBO

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

Emergency lighting units PC COMBO

SubstiTUBE Advanced ST8-HA4

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

Emergency lighting units EM INVERTER

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

Emergency lighting units EM powerled. EM powerled BASIC 15 W CLE Emergency lighting units LED

Emergency lighting units EM INVERTER

Emergency lighting units EM powerled

Emergency lighting units EM powerled

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

Datasheet. OSRAM SubstiTUBE Trio 2

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

Emergency lighting units EM converterled

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

FL ballasts Electronic fixed output. PC TCL PRO, W PC PRO compact

Emergency lighting units EM powerled. EM powerled BASIC 4W Emergency lighting LED Driver

Emergency lighting units EM powerled. EM powerled BASIC 15 W CLE Emergency lighting LED Driver

Emergency lighting units EM powerled

Emergency lighting units EM powerled

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM powerled

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

ELEMENT. Product family datasheet. Constant Voltage Non dimmable

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

PC T8 TEC, W PC TEC

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

Emergency lighting units EM series. EM BASIC, V BASIC version

Emergency lighting units EM powerled

FL ballasts Electronic fixed output PC T8 PRO, W PC PRO T8

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

Emergency lighting units EM converterled

Electronic ballasts for fluorescent lamps Multi-lamp ECG. PC T5 PRO-M lp, W T5, T8, compact (CFL) and T5c circular fluorescent lamps

FL ballasts Electronic fixed output

Electronic ballasts for fluorescent lamps Professional electronic ballast

HFX & HFXE T8 ELECTRONIC BALLAST & COMBINED ELECTRONIC BALLAST AND EMERGENCY INVERTER FOR EX-ENVIRONMENT

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Emergency lighting units EM converterled

EM BASIC V 50/60 Hz

Emergency lighting units EM powerled

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

ILED Dorado. User Manual

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

FL ballasts Electronic fixed output

ILED Aquarius Illuminated Windsock. User Manual

Emergency lighting units EM converterled

Easy and safe installation

Emergency Light Fitting for Fluorescent Lamps Series 6009

Compact Sheet-steel Emergency Light Fitting Series 6118/1

7 Lighting Technology

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Emergency lighting units EM powerled

IQL Helios Area-/Streetlight. User Manual

Emergency lighting units EM powerled

PC T8 PRO, W T8 fluorescent lamps

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Emergency lighting units EM powerled

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Emergency lighting units EM powerled

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

Operating Instructions

FL ballasts Electronic fixed output. PC TC PRO 1/2x9 70 W PC PRO compact

7 Lighting Technology

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

TrustSight LED Emergency Lighting

7 Lighting Technology

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

SERIES 54 Inductive Proximity Sensor

Technical Documentation

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Emergency Luminaire with LED Series EXLUX 6409/1

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

QTi 2X28/54/35/49 GII

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

LED Driver Compact fixed output

LED Driver Compact fixed output

Emergency lighting units EM series

LED Emergency Lighting

Datasheet / Product specification Model: Solar AAA

Angle Sensor WS1. RE Edition: Replaces:

EURO ZB.1 Installation example

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

Solenoid coils VACF Type codes

Lighting series JSNEVW Lighting series JLEDW LEUCHTEN 2011/09

ATEX II 2G Ex ib IIC T4 Gb. ATEX II 2D Ex ib IIIC T150 C Db ATEXBEAM

Emergency Lighting Control Gear

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Transcription:

Data sheet Integrated emergency converter for fluorescent lamps zone 2 Ex 100,000 h suitable for zone 2 hazardous areas For mains and battery supply Integrated battery management inear V

inear V Emergency converter More than 25 years of experience in the design and development of electronic lighting products, the close cooperation with test authorities and the joint research in the sector of explosion protection enable the company Hadler to develop products in accordance with market trends which will exactly meet the requirements. Function and, above all, safety will take priority over other requirements. Table of contents NE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4 NE 2 x 36 W T8, 230 V, 7 Ah, 3.0 h 10 NE 2 x 18 W T8, 230 V, 4 Ah, 1.5 h 16 NE 2 x 18 W T8, 230 V, 4 Ah, 3.0 h 22 Furthermore, in accordance with the company philosophy, uxtronic ballasts also reflect the second idea : Features offering an additional benefit and using the full competence of the company Hadler to allow for a unique position in the market. Both large-scale and small-scale series of the uxtronic ballasts can be produced in a cost-effective way. The proximity to the market allows for short delivery times. Michael amkowski Head of Research & Development 2 I data sheet emergency converter inear V 07/2015 Technical changes reserved www.luxtronic.de 3

NE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h Input Rated supply voltage 220 240 V Mains frequency 50 60 Hz Input voltage range a.c. 198 264 V Input voltage range d.c. Power factor 0.98 at full load Total Harmonic Distortion < 11.5 % Temperature, ifetime Ambient temperature range -20 60 C Max. case temperature T c 70 C T a 40 C 50 C 60 C T c 50 C 60 C 70 C lifetime > 150,000 h 100,000 h 65,000 h Output Max. No. of ECG per circuit breaker amp type Connection type Output dimming Dimming range 2 x 36 W T8 Serial Type B10 8 pcs. C10 B16 C16 22 pcs. Efficiency Wiring Energy Efficiency Index Status ED cable length cm Battery Input wire cross-section Output wire cross-section Type 5 cells NiCd, 4 Ah The wiring should be short and without crossings for best EMC results. Charge current Charge voltage 210 ma 4.8 7.55 V Dimensions Discharge current 2.05 A ength x Width x Height 248 x 65 x 32 mm End of discharge 4.8 V Mounting hole distance D 240 mm Deep discharge current < 3 ma Mounting screws M4 max. EBF 0.25 Interface Dimming Interface Interface control current (see schematic view on the right) Ordering data Weight Packaging unit 0.4 kg 32 pcs. W H Dimming curve Order No. 3 E 236 03 0 D 4 I data sheet emergency converter inear V 07/2015 Technical changes reserved www.luxtronic.de 5

NE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h Emergency lighting performance The emergency converter operates two lamps in series connection when in maintained mains mode. Because the normative declared EBF relates to the emergency lamp only, total light output in emergency mode will be approximately 50% of the normative declared EBF compared to the values in maintained mains mode. The device will recharge the battery normally after abnormal operating conditions given in EN 61347-2-7 clause 22.3 (battery short-circuit). Battery ground is internally connected to the functional earthing to reduce emitted interferences. The insulation against line conductors and N meets the requirements for basic insulation. Standards EN 55015:2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 61547:2009 EN 61347-1:2008 + A1:2011 + A2:2013 EN 61347-2-3:2011 EN 61347-2-7:2012 EN 60929:2012 EN 60079-0:2012 + A11:2013 EN 60079-15:2010 Markings To achieve sufficient lamp life in switched maintained operation both lamps are warm-started within 1.5 s. When switching to emergency mode, instant-starting is used to ensure that time-to-light is less than 0.5 s. The emergency converter is intended for use in luminaires for high-risk task area lighting. acc. to IEC 61374-1 C.5 e) Wiring diagram Functional earthing via housing required 5 cells 4 Ah NiCd amp 1 is used during emergency operation 1 1 2 3 4 ' N Status Emergency lighting unit 1.5 h rated duration Part no.: 3 E 236 03 0 U N (V) f N (Hz) I N (A) ta [ C] 8.5-9.5 mm 0.5-1.5 U-OUT = 400 V Temp.-Test tc = 70 C max. 2 5 6 7 8 2 x 36 W T8 220...240 50...60 0.32 0.98-20...60 Made in Germany www.uxtronic.de 6 I data sheet emergency converter inear V 07/2015 Technical changes reserved www.luxtronic.de 7

NE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h Safety instructions Please carefully read these instructions prior to installation and keep them for later reference. Installation precautions This control gear may be installed into housings of explosion protected luminaires with a minimum type of protection of the housing of IP54 according to IEC 60529. This emergency converter is intended for operation of two T8 fluorescent lamps in explosion protected luminaires. Do not use this product for other than intended use. Dismantled length of wires has to be between 8.5 and 9.5 mm. At use of multistrand wires, conductor sleeves have to be used. Permissible cross section of wires is from 0.5 up to 1.5 mm². Maximum temperature rise at internal components is 60 K. Hadler GmbH declares that this device is in conformity with the EU explosion protection directive 94/9/EC (ATEX). Status ED and connected cable need to be fixed to avoid mechanical stress on cable and solder joints. The sign "U" placed after ATEX marking indicates, that the corresponding declaration is not equivalent to a Statement of Conformity for an equipment or protective system. It is intended to be used as a basis for certifiying an equipment or protective system. Devices contain no field-serviceable parts. In case of malfunction, contact the manufacturer. Detailed product datasheets are available at www.hadler-gmbh.de. For operation conditions see pages 4 6. 8 I data sheet emergency converter inear V 07/2015 Technical changes reserved www.luxtronic.de 9

NE 2 x 36 W T8, 230 V, 7 Ah, 3.0 h Input Rated supply voltage 220 240 V Mains frequency 50 60 Hz Input voltage range a.c. 198 264 V Input voltage range d.c. Power factor 0.98 at full load Total Harmonic Distortion < 11.5 % Temperature, ifetime Ambient temperature range -20 60 C Max. case temperature T c 70 C T a 40 C 50 C 60 C T c 50 C 60 C 70 C lifetime > 150,000 h 100,000 h 65,000 h Output Max. No. of ECG per circuit breaker amp type Connection type Output dimming Dimming range 2 x 36 W T8 Serial Type B10 8 pcs. C10 B16 C16 22 pcs. Efficiency Wiring Energy Efficiency Index Status ED cable length cm Battery Input wire cross-section Output wire cross-section Type 5 cells NiCd, 7 Ah The wiring should be short and without crossings for best EMC results. Charge current Charge voltage 340 ma 4.8 7.55 V Dimensions Discharge current 1.75 A ength x Width x Height 248 x 65 x 32 mm End of discharge 4.8 V Mounting hole distance D 240 mm Deep discharge current < 3 ma Mounting screws M4 max. EBF 0.25 Interface Dimming Interface Interface control current (see schematic view on the right) Ordering data Weight Packaging unit 0.4 kg 32 pcs. W H Dimming curve Order No. 3 E 236 03 3 D 10 I data sheet emergency converter inear V 07/2015 Technical changes reserved www.luxtronic.de 11

NE 2 x 36 W T8, 230 V, 7 Ah, 3.0 h Emergency lighting performance The emergency converter operates two lamps in series connection when in maintained mains mode. Because the normative declared EBF relates to the emergency lamp only, total light output in emergency mode will be approximately 50% of the normative declared EBF compared to the values in maintained mains mode. The device will recharge the battery normally after abnormal operating conditions given in EN 61347-2-7 clause 22.3 (battery short-circuit). Battery ground is internally connected to the functional earthing to reduce emitted interferences. The insulation against line conductors and N meets the requirements for basic insulation. Standards EN 55015:2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 61547:2009 EN 61347-1:2008 + A1:2011 + A2:2013 EN 61347-2-3:2011 EN 61347-2-7:2012 EN 60929:2012 EN 60079-0:2012 + A11:2013 EN 60079-15:2010 Markings To achieve sufficient lamp life in switched maintained operation both lamps are warm-started within 1.5 s. When switching to emergency mode, instant-starting is used to ensure that time-to-light is less than 0.5 s. The emergency converter is intended for use in luminaires for high-risk task area lighting. acc. to IEC 61374-1 C.5 e) Wiring diagram Functional earthing via housing required 5 cells 7 Ah NiCd 1 amp 1 is used during emergency operation 1 2 3 4 ' N Status Emergency lighting unit 3.0 h rated duration Part no.: 3 E 236 03 3 U N [V] f N [Hz] I N [A] ta [ C] 8.5-9.5 mm 0.5-1.5 U-OUT = 400 V Temp.-Test tc = 70 C max. 2 5 6 7 8 2 x 36 W T8 220...240 50...60 0.32 0.98-20...60 Made in Germany www.uxtronic.de 12 I data sheet emergency converter inear V 07/2015 Technical changes reserved www.luxtronic.de 13

NE 2 x 36 W T8, 230 V, 7 Ah, 3.0 h Safety instructions Please carefully read these instructions prior to installation and keep them for later reference. Installation precautions This control gear may be installed into housings of explosion protected luminaires with a minimum type of protection of the housing of IP54 according to IEC 60529. This emergency converter is intended for operation of two T8 fluorescent lamps in explosion protected luminaires. Do not use this product for other than intended use. Dismantled length of wires has to be between 8.5 and 9.5 mm. At use of multistrand wires, conductor sleeves have to be used. Permissible cross section of wires is from 0.5 up to 1.5 mm². Maximum temperature rise at internal components is 60 K. Hadler GmbH declares that this device is in conformity with the EU explosion protection directive 94/9/EC (ATEX). Status ED and connected cable need to be fixed to avoid mechanical stress on cable and solder joints. The sign "U" placed after ATEX marking indicates, that the corresponding declaration is not equivalent to a Statement of Conformity for an equipment or protective system. It is intended to be used as a basis for certifiying an equipment or protective system. Devices contain no field-serviceable parts. In case of malfunction, contact the manufacturer. Detailed product datasheets are available at www.hadler-gmbh.de. For operation conditions see pages 10 12. 14 I data sheet emergency converter inear V 07/2015 Technical changes reserved www.luxtronic.de 15

NE 2 x 18 W T8, 230 V, 4 Ah, 1.5 h Input Rated supply voltage 220 240 V Mains frequency 50 60 Hz Input voltage range a.c. 198 264 V Input voltage range d.c. Power factor 0.96 at full load Total Harmonic Distortion < 19.3 % Temperature, ifetime Ambient temperature range -20 60 C Max. case temperature T c 70 C T a 40 C 50 C 60 C T c 50 C 60 C 70 C lifetime > 150,000 h 100,000 h 65,000 h Output Max. No. of ECG per circuit breaker amp type Connection type Output dimming Dimming range 2 x 18 W T8 Serial Type B10 8 pcs. C10 B16 C16 22 pcs. Efficiency Wiring Energy Efficiency Index Status ED cable length 70 cm Battery Input wire cross-section Output wire cross-section Type 5 cells NiCd, 4 Ah The wiring should be short and without crossings for best EMC results. Charge current Charge voltage 210 ma 4.8 7.55 V Dimensions Discharge current 2.05 A ength x Width x Height 248 x 65 x 32 mm End of discharge 4.8 V Mounting hole distance D 240 mm Deep discharge current < 3 ma Mounting screws M4 max. EBF 0.5 Interface Dimming Interface Interface control current (see schematic view on the right) Ordering data Weight Packaging unit 0.4 kg 32 pcs. W H Dimming curve Order No. 3 E 218 03 0 D 16 I data sheet emergency converter inear V 07/2015 Technical changes reserved www.luxtronic.de 17

NE 2 x 18 W T8, 230 V, 4 Ah, 1.5 h Emergency lighting performance The emergency converter operates two lamps in series connection when in maintained mains mode. Because the normative declared EBF relates to the emergency lamp only, total light output in emergency mode will be approximately 50% of the normative declared EBF compared to the values in maintained mains mode. The device will recharge the battery normally after abnormal operating conditions given in EN 61347-2-7 clause 22.3 (battery short-circuit). Battery ground is internally connected to the functional earthing to reduce emitted interferences. The insulation against line conductors and N meets the requirements for basic insulation. Standards EN 55015:2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 61547:2009 EN 61347-1:2008 + A1:2011 + A2:2013 EN 61347-2-3:2011 EN 61347-2-7:2012 EN 60929:2012 EN 60079-0:2012 + A11:2013 EN 60079-15:2010 Markings To achieve sufficient lamp life in switched maintained operation both lamps are warm-started within 1.5 s. When switching to emergency mode, instant-starting is used to ensure that time-to-light is less than 0.5 s. The emergency converter is intended for use in luminaires for high-risk task area lighting. acc. to IEC 61374-1 C.5 e) Wiring diagram Functional earthing via housing required 5 cells 4 Ah NiCd 1 amp 1 is used during emergency operation 1 2 3 4 ' N Status Emergency lighting unit 1.5 h rated duration Part no.: 3 E 218 03 0 U N [V] f N [Hz] I N [A] ta [ C] 8.5-9.5 mm 0.5-1.5 U-OUT = 400 V Temp.-Test tc = 70 C max. 2 5 6 7 8 2 x 18 W T8 220...240 50...60 0.18 0.96-20...60 Made in Germany www.uxtronic.de 18 I data sheet emergency converter inear V 07/2015 Technical changes reserved www.luxtronic.de 19

NE 2 x 18 W T8, 230 V, 4 Ah, 1.5 h Safety instructions Please carefully read these instructions prior to installation and keep them for later reference. Installation precautions This control gear may be installed into housings of explosion protected luminaires with a minimum type of protection of the housing of IP54 according to IEC 60529. This emergency converter is intended for operation of two T8 fluorescent lamps in explosion protected luminaires. Do not use this product for other than intended use. Dismantled length of wires has to be between 8.5 and 9.5 mm. At use of multistrand wires, conductor sleeves have to be used. Permissible cross section of wires is from 0.5 up to 1.5 mm². Maximum temperature rise at internal components is 60 K. Hadler GmbH declares that this device is in conformity with the EU explosion protection directive 94/9/EC (ATEX). Status ED and connected cable need to be fixed to avoid mechanical stress on cable and solder joints. The sign "U" placed after ATEX marking indicates, that the corresponding declaration is not equivalent to a Statement of Conformity for an equipment or protective system. It is intended to be used as a basis for certifiying an equipment or protective system. Devices contain no field-serviceable parts. In case of malfunction, contact the manufacturer. Detailed product datasheets are available at www.hadler-gmbh.de. For operation conditions see pages 16 18. 20 I data sheet emergency converter inear V 07/2015 Technical changes reserved www.luxtronic.de 21

NE 2 x 18 W T8, 230 V, 4 Ah, 3.0 h Input Rated supply voltage 220 240 V Mains frequency 50 60 Hz Input voltage range a.c. 198 264 V Input voltage range d.c. Power factor 0.96 at full load Total Harmonic Distortion < 19.3 % Temperature, ifetime Ambient temperature range -20 60 C Max. case temperature T c 70 C T a 40 C 50 C 60 C T c 50 C 60 C 70 C lifetime > 150,000 h 100,000 h 65,000 h Output Max. No. of ECG per circuit breaker amp type Connection type Output dimming Dimming range 2 x 18 W T8 Serial Type B10 8 pcs. C10 B16 C16 22 pcs. Efficiency Wiring Energy Efficiency Index Status ED cable length 70 cm Battery Input wire cross-section Output wire cross-section Type 5 cells NiCd, 4 Ah The wiring should be short and without crossings for best EMC results. Charge current Charge voltage 210 ma 4.8 7.55 V Dimensions Discharge current 1 A ength x Width x Height 248 x 65 x 32 mm End of discharge 4.8 V Mounting hole distance D 240 mm Deep discharge current < 3 ma Mounting screws M4 max. EBF 0.25 Interface Dimming Interface Interface control current (see schematic view on the right) Ordering data Weight Packaging unit 0.4 kg 32 pcs. W H Dimming curve Order No. 3 E 218 03 2 D 22 I data sheet emergency converter inear V 07/2015 Technical changes reserved www.luxtronic.de 23

NE 2 x 18 W T8, 230 V, 4 Ah, 3.0 h Emergency lighting performance The emergency converter operates two lamps in series connection when in maintained mains mode. Because the normative declared EBF relates to the emergency lamp only, total light output in emergency mode will be approximately 50% of the normative declared EBF compared to the values in maintained mains mode. The device will recharge the battery normally after abnormal operating conditions given in EN 61347-2-7 clause 22.3 (battery short-circuit). Battery ground is internally connected to the functional earthing to reduce emitted interferences. The insulation against line conductors and N meets the requirements for basic insulation. Standards EN 55015:2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 61547:2009 EN 61347-1:2008 + A1:2011 + A2:2013 EN 61347-2-3:2011 EN 61347-2-7:2012 EN 60929:2012 EN 60079-0:2012 + A11:2013 EN 60079-15:2010 Markings To achieve sufficient lamp life in switched maintained operation both lamps are warm-started within 1.5 s. When switching to emergency mode, instant-starting is used to ensure that time-to-light is less than 0.5 s. The emergency converter is intended for use in luminaires for high-risk task area lighting. acc. to IEC 61374-1 C.5 e) Wiring diagram Functional earthing via housing required 5 cells 4 Ah NiCd 1 amp 1 is used during emergency operation 1 2 3 4 ' N Status Emergency lighting unit 3.0 h rated duration Part no.: 3 E 218 03 2 U N [V] f N [Hz] I N [A] ta [ C] 8.5-9.5 mm 0.5-1.5 U-OUT = 400 V Temp.-Test tc = 70 C max. 2 5 6 7 8 2 x 18 W T8 220...240 50...60 0.18 0.96-20...60 Made in Germany www.uxtronic.de 24 I data sheet emergency converter inear V 07/2015 Technical changes reserved www.luxtronic.de 25

NE 2 x 18 W T8, 230 V, 4 Ah, 3.0 h Safety instructions Please carefully read these instructions prior to installation and keep them for later reference. Installation precautions This control gear may be installed into housings of explosion protected luminaires with a minimum type of protection of the housing of IP54 according to IEC 60529. This emergency converter is intended for operation of two T8 fluorescent lamps in explosion protected luminaires. Do not use this product for other than intended use. Dismantled length of wires has to be between 8.5 and 9.5 mm. At use of multistrand wires, conductor sleeves have to be used. Permissible cross section of wires is from 0.5 up to 1.5 mm². Maximum temperature rise at internal components is 60 K. Hadler GmbH declares that this device is in conformity with the EU explosion protection directive 94/9/EC (ATEX). Status ED and connected cable need to be fixed to avoid mechanical stress on cable and solder joints. The sign "U" placed after ATEX marking indicates, that the corresponding declaration is not equivalent to a Statement of Conformity for an equipment or protective system. It is intended to be used as a basis for certifiying an equipment or protective system. Devices contain no field-serviceable parts. In case of malfunction, contact the manufacturer. Detailed product datasheets are available at www.hadler-gmbh.de. For operation conditions see pages 22 24. 26 I data sheet emergency converter inear V 07/2015 Technical changes reserved www.luxtronic.de 27

Hadler GmbH Fritzlarer Straße 19 34587 Felsberg-Neuenbrunslar Tel.: +49 5662 9399-0 Fax: +49 5662 9399-29 E-Mail: info@hadler-gmbh.de http://www.hadler-gmbh.de/en/luxtronic/all-products/