Valves. Slow opening and rapid closing solenoid valves VM-L (E1111 rev /11/2012)

Similar documents
Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012)

Orifice Flow Meters POP-S (E5720 rev /03/2013)

Burners. Pilot Heads BTC & BTSA (E3121 rev /09/2010)

Burners. Pilot Heads BTC & BTSA (E3121 rev /04/2018)

Burners. Ribbon linear flame burners AB & ABM (E3010 rev /11/2017)

Burners. Metallic free flame burners. EMB (E3004 rev /02/2010)

Burners. Self-recuperative burners high speed free flame REKO-SIK-FF (E3901FF rev /05/2009)

OIL REGULATORS RFG SERIES FEATURES APPLICATIONS DESCRIPTION INSTALLATION. Bulletin E5301 rev03 02/04/03. Body and valve seat: Shutter seat:

Valves. Double stage and modulant motorized butterfly valves MRBV & MRBV-CMAP (E1302 rev /04/2011)

Free flame burners EMB (E3004 rev /02/2015)

Burners. High velocity LOW NOx combustion air burners EMB-SIK-NxT (E3507 rev /11/2016)

Burners. Self-recuperative burners high speed with flat flame REKO-SIK-SW (E3903 rev /06/2015)

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE

Radiant tube burners RT (E3900 rev /01/2018)

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

Electronics. Permanent operation microprocessor burner control device ESA GENIO-S (E7021 rev /05/2015)

Electronics. Permanent operation microprocessor burner control device ESA GENIO-PRS (E7022 rev /05/2015)

VMH. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN EE

PCS. Proof of closure switch for safety gas valves. delta-elektrogas.com EE

VF VFH. elektrogas.com. Butterfly valves DN40 DN150 EE155-11/11

Electronics. Permanent Operation Microprocessor Burner Control ESA ESTRO-PO (E7014PO rev /05/2013)

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

ATTENTION: Industrial machinery for professional use. These instructions are for qualified personnel USE AND MAINTENANCE MANUAL

USE AND MAINTENANCE MANUAL

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

RS/M SERIES. Modulating Gas Burners FIRING RATES

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

Operating and Installation Instructions Diaphragm Gas Sampling Pumps

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

Installation and Service Instructions for Self Adjust Brakes 81,000 Series

GENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VE4000 & VE5000 SERIES

US - UP2/OIL 12V US - UP2/OIL 24V

ONE STAGE GAS BURNERS RDBS SERIES

Installation and Service Instructions for Self Adjust Brakes 82,000 Series

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

These installation and maintenance instructions must be read in full and completely understood before the installation!

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

CIRCLE SEAL CONTROLS

INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL MANUAL

Automatic concealed bollards 275 H600 and 275 H800 with pit

TECHNICAL CATALOGUE BALL VALVES: PARIS

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

B21 Series BASOTROL Gas Valve

TECHNICAL CATALOGUE BLOCK CHECK AND FOOT VALVES

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

SERIES 2000 GAS SAFETY SHUT OFF VALVE

Installation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B)

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

TECHNICAL CATALOGUE EUROPA CHECK AND FOOT VALVES

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Performa Winch 80.3 STP

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

Boiler room components 0459EN October 2013 Safety pressure switch with manual reset

TECHNICAL CATALOGUE GAS BALL VALVES: BERLIN

BAH series Use and Maintenance Manual

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Installation and Maintenance Manual MRW-01. Radial Winch 20 ST

PNEUMATIC ACTUATORS ASSEMBLY & MAINTENANCE PROCEDURES. Ref. Doc. MMMACTREGDRE English Rev.2 January 2012 ADA & ASR SERIES DOUBLE ACTING ACTUATOR ADA

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Double motor belt grinding machine

Instructions for installation, operation and maintenance of: GATE VALVE

TECHNICAL MANUAL MT064

Swing Piston Compressors and Vacuum Pumps

USE AND MAINTENANCE MANUAL

ILED Dorado. User Manual

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Performa Winch 80.2 STP

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

Installation and Maintenance Manual MRW-02. Radial Winch 20 ST

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

GT-200 GATE VALVES PN16, Screwed end

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM

Plunger Heads Use and Maintenance Manual

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

Installation, Operation, and Maintenance Manual

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

Installation and Maintenance Manual MRW-04. Radial Winch 70.3 ST

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

VE Series. Class "A" Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various

AVK SERIES 55 AND 06 GATE VALVES, DN 450/500/600

Turbocharger / A100-L Original assembly instructions English

CIRCLE SEAL CONTROLS

Performa Winch 50.2 STP

BELT CONVEYOR PNL/4 Series User and maintenance manual

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

TECHNICAL CATALOGUE BALL VALVES: IDEAL

PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2

EC4 SERIES CRYOGENIC VALVES 1/4 2 Sizes

26 Series Stainless Steel 2-way Ball Valves

HexPro Series Low Profile Wrenches

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

Transcription:

Valves Slow opening and rapid closing solenoid valves VM-L (E1111 rev. 03-19/11/2012)

GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff, respecting the norms present at the time and place of the installation. ¾ To avoid damage to people and things, it is essential to observe all the points indicated in this handbook. The reported indications do not exonerate the Client/User from observing general or specific laws concerning accidents and environmental safeguarding. ¾ The operator must wear proper DPI clothing (shoes, helmets...) and respect the general safety, prevention and precaution norms. ¾ To avoid the risks of burns or high voltage electrocution, the operator must avoid all contact with the burner and its control devices during the ignition phase and while it is running at high temperatures. ¾ All ordinary and extraordinary maintenance must be performed when the system is stopped. To dispose of the product, abide by the local legislations regarding it. GENERAL NOTES: ¾ In accordance to the internal policy of constant quality improvement, ESA-PYRONICS reserves the right to modify the technical characteristics of the present document at any time and without warning. ¾ It is possible to download technical sheets which have been updated to the latest revision from the www.esapyronics.com website. CERTIFICATIONS: ¾ To assure correct and safe use of the combustion plant, it is of extreme importance that the contents of this document be brought to the attention of and be meticulously observed by all personnel in charge of controlling and working the devices. ¾ The functioning of a combustion plant can be dangerous and cause injuries to persons or damage to equipment. Every burner must be provided with certified combustion safety and supervision devices. ¾ The burner must be installed correctly to prevent any type of accidental/undesired heat transmission from the flame to the operator or the equipment. EN746-2 The products manufactured by ESA-PYRONICS have been created in conformity to the UNI EN 746-2:2010 Norms: Equipment for industrial thermal process - Part 2: Safety requirements for combustion and the movement and treatment of combustible elements. This norm is in harmony with the Machine Directive 2006/42/CE. It is certified that the products in question respect all the requirements prescribed by the above mentioned Norms and Directives. These have been designed, produced, controlled and tested in accordance to the company s internal procedures for quality control, certified in conformity with the UNI EN ISO 9001:2008 Norm by DNV Italia s.r.l. The valves comply with the UNI EN 161 Norm: Automatic isolating valves for gas burners and gas-user equipment, in Class A, group 2, certificate n. CE 0063AQ1350 ¾ The performances indicated in this technical document regarding the range of products are a result of experimental tests carried out at ESA-PYRONICS. The tests have been performed using ignition systems, flame detectors and supervisors developed by ESA-PYRO- NICS. The respect of the above mentioned functioning conditions cannot be guaranteed if equipment, which is not present in the ESA-PYRONICS catalogue, is used. The products conform to the requests for the Russian market according to the GOST and GOSGORTEKHNADZOR certifications. CONTACTS / ASSISTANCE: Headquarters: Esa S.p.A. Via Enrico Fermi 40 24035 Curno (BG) - Italy Tel +39.035.6227411 Fax +39.035.6227499 esa@esacombustion.it www.esapyronics.com International Sales: Pyronics International s.a. Zoning Industriel, 4ème rue B-6040 Jumet - Belgium Tel +32.71.256970 Fax +32.71.256979 marketing@pyronics.be www.esapyronics.com 2

The VM-L is an electromagnetic mono-stage valve. It opens slowly and closes rapidly and is a normally closed valve complying with the UNI EN 161 Norm. APPLICATIONS ¾Gas interception on decompression units. ¾Air/gas interception for burners. GENERAL: CHARACTERISTICS ¾Working pressure: 360 mbar ¾Fluid temperature: < 40 C ¾Adjustable capacity: 0-100 % ¾Voltage rating: 110/230 V 50/60 Hz ¾Voltage (on request): 24 VAC/DC ¾Tension tolerance: from -15% to +10% ¾Working temperature: from -15 C to +60 C ¾Opening time: from 4 to 25 s ¾Closing time: < 1 second ¾Coil direction: 360 ¾Protection: IP 54 (EN 60529) ¾Cable gland: M20 x 1,5 ¾Dust filter: incorporated ¾Limit switch: on request ¾Mounting: in any position except with coil facing downwards ¾Manufactured in accordance to the EN161 Norm (EC certificate n. 0063AQ1350) in class A group 2. F1111I03 MATERIAL COMPOSITION: ¾Valve body: ¾Seals: aluminum, copper, steel PTFE, NBR, FPM DESCRIPTION The VM-L series solenoid valves are interception devices operating with auxiliary electrical energy suited for block maneuvers and gas or air supply in burners at atmospheric or blown air pressures, for furnaces and other applications that use gas as fuel. When the coil is not powered, the spring acts on the shutter, keeping the gas passage closed (intrinsic safety). In this condition, gas is present at line pressure in the inlet chamber and by pushing against the shutter it increases the sealing force. When the coil is powered, the valve opens slowly due to the hydraulic brake effect, overcoming the force of the spring and gas pressure. The part of rapid opening, and thus the initial flow, can be regulated by the special regulation screw. In the same way the flow and opening velocity can also be adjusted. If power is cut off from the coil, the valve closes rapidly, interrupting the gas passage. F1111I04 www.esapyronics.com 3

FLOWCHART 10000 3000 2000 1000 500 400 VM-L82 DN80 VM-L72DN65 VM-L6 Rp.2 VM-L4 Rp. 1.1/2 300 Natural gas flow @ 20 C P.S.= 1 [Nm 3 /h] 200 100 50 40 30 20 10 9 7 8 6 5 4 3 VM-L3 Rp.1 VM-L2 Rp. 3/4 VM-L1 Rp. 1/2 VM-L0 Rp. 3/8 2 1 0.5 0.1 0.5 1 2 3 4 5 10 50 100 200 Pressure drop [mbar] G1111I01 www.esapyronics.com 4

WARNINGS ¾Make sure that the working pressure and fluid temperature are lower than the maximum values allowed. ¾Check correct installation of the valve before starting the flow in the pipes. ¾In case of valve malfunctioning, follow the indications in the present manual at the Maintenance chapter or contact ESA-PYRONICS assistance. ¾Any modification or repair done by third parties could compromise the application safety and cause the general warrantee conditions to automatically expire. INSTALLATION Do not expose the valve to direct sunlight, heat sources or near combustion products, liquids, solvents or corrosive gases. ¾Check that the line pressure is lower than the maximum working pressure allowed. ¾Check that the arrow on the valve body is pointing in the correct flow direction. ¾The valve may be installed in any position (coil can be horizontal or vertical), except with coil facing downwards. ¾Ensure that there are no foreign objects inside the valve before assembling. If necessary, blow with compressed air. ¾Check the correct alignment of the attachment pipes. Keep a certain distance from the walls allowing air to circulate freely. ¾Leave enough space above the solenoid valve to extract the coil in case of replacement. 02 01 02 THREADED MODELS: D1111I01 1 - Make sure that the threads conform to the valve that must be installed (pos. 01) according to the UNI ISO 7/1 Norm. 2 - Use thread-sealing paste on the male threads of the pipes (pos. 02) paying attention not to use too much as it could enter the valve and damage its seal. 3 - Screw the valve onto the pipe using an appropriate tool. Do not use the coil as a lever and only use the special seats on the body. FLANGED MODELS: 01 02 02 03 04 05 1 - Weld the flanges (pos. 03) on the ends of the pipes, eliminating any welding burrs. 2 - Place the gaskets (pos. 02) between the flange (pos. 03) and the valve (pos. 04) and insert the bolts (pos. 04). 3 - Using appropriate tools, progressively tighten the bolts (pos. 04) crosswise. 4 - Avoid excessive tightening and mount without tension. 04 05 03 D1111I02 www.esapyronics.com 5

ELECTRIC WIRING D1110I03 Before making any electrical connection, ensure that the voltage and frequency of the solenoid valve correspond to the electrical supply available. 1 - Disconnect electrical supply and close the gas. 2 - Using a screwdriver unscrew the screws (pos. 04) of the protection cover (pos. 03) of the connection box. 3 - Unscrew the cablegrip (pos. 07) and remove the locking ring (pos. 09) and the cone shaped gasket (pos. 08). 4 - Insert the cable respectively into the cablegrip, inside the locking ring of the cable gland, therefore inside the appropriate hole in the cover. 5 - Connect power to the terminals (pos. 01) of the rectifier circuit following the symbols indicated. In the case of valves powered at 12Vdc or 24Vdc, when the + terminals are used, do not invert polarity. 6 - Always make sure that the ground protection is connected to the related clamps (pos. 01). 7 - If the cable passage takes place through the hole that was originally closed, use the rubber pad under the cap to close the other hole if left open. 8 - Pull the wire and screw the cablegrip back on and then the cover, paying attention to position the gasket correctly (pos. 02). REGULATION RAPID STROKE REGULATION (Vstart) Once tested, the solenoid valves are supplied regulated at completely slow stroke with duration of about 14s. The rapid stroke time is regulated by unscrewing and removing the plastic cap found at the ends of the damper and intervening with a hex wrench turning the screw clockwise to decrease the stroke time or anticlockwise to increase it. Each anticlockwise turn frees 1mm of the rapid stroke. The opening time and shutter stroke (with maximum flow) remain unchanged. After regulation, screw the plastic cap back on. N.B.: In DN65 and DN80 models the minimum adjustable rapid part is 3mm. D1110I04 www.esapyronics.com 6

REGOLAZIONE FLOW REGULATION (Vmax) The solenoid valves provided are adjusted to the maximum flow rate (regulation screw completely open). The flow can be regulated from 0m³/h to the maximum flow allowed. Flow regulation is done through the inner screw underneath the plastic cap found on the valve damper. Unscrew and remove the cap and with the valve open (in voltage), keeping the external screw in place with a wrench, delicately turn the screw until you can feel the resistance against the nucleus. Starting from that position each clockwise turn decreases the flow of about 20% for ½, 12% for ¾ - 1, 8% for 1 ¼ to 1 ½ - 2. Rapid stroke regulations below 1mm and flow regulations below about 40% of the flow in the attachment pipes is not advisable as with variations in the line pressure this could create problems in flow regime. After regulating, screw the cap on again. OPENING TIME REGULATION (T) To regulate the opening time one must intervene on the screw placed on the side of the damper. The standard time of 12-14 seconds is valid for almost all of the applications. In the anticlockwise direction, starting from the completely closed screw, in about two turns, ½ - ¾ -1 is reached, and in one and a half turns 1 ¼ - 1 ½ - 2 is reached. Starting from the totally closed position each quarter clockwise turn increases the opening time by about 2-3 seconds and each ¼ anticlockwise rotation decreases it by the same amount of seconds. Avoid forcing the limit switch as well as regulation over 25 seconds that could create turbulence during start-up. ORDINARY MAINTENANCE For correct maintenance of the VM-L solenoid valves, scrupulously abide by the following instructions. Before carrying out maneuvers with the plant on, make sure that the process and operator safety is not compromised. If necessary check with plant off. INTEGRITY CHECK SOLENOID VALVE MOVEMENT ¾Checking for the presence of valve movement obstructions takes place by completely opening the valve and visually checking that there is nothing obstructing or limiting its stroke. ¾The integrity of the gaskets and threads can be checked visually. If necessary, used liquid gas detector. GENERAL MAINTENANCE PLAN Maintenance and installation must be carried out by technically qualified staff respecting the Norms in force. After installation has take place it is advisable to test the tightness of the threads or flange connections. Operation Type (*) Advised time Notes Gasket integrity O annual Check that there are no leaks outside Thread integrity O annual Check that there are no leaks outside Maintenance of the solenoid valve S annual Check the valve conditions NOTES: Key: O = Ordinary / E = Extraordinary (*) it is suggested that the gaskets are replaced every time the valve is disassembled. www.esapyronics.com 7

EXTRAORDINARY MAINTENANCE For correct maintenance of the VM-L solenoid valves scrupulously follow the instructions with plant off. Before proceeding with any type of installation or service, close the upstream gas supply and disconnect the power supply. BOLT TIGHTENING ¾ Checking the bolt tightening must take place when the plant is off. GASKET REPLACEMENT 1 - Progressively unscrew the screws that fix the solenoid valve crosswise. Extract the solenoid valve and check the conditions of its internal components. 2 - Clean the inside of the valve body with a clean cloth and compressed air. Do not use tools that could damage the internal parts. 3 - Check that the valve moves without friction. 4 - Replace the gaskets and reassemble the valve in its seat, according to the steps indicated in the INSTALLA- TION section. 5 - Finally check that the valve moves freely without any obstructions. COIL REPLACEMENT INTERNAL CLEANING Dust and possible foreign objects can easily be removed from the filter or from the gas passage seat. 1 - Close the ball valve upstream of the plant. 2 - Remove the coil as described previously. 3 - Progressively unscrew the screws that fix the upper flange crosswise. During this operation some residual gas could leak out from the valve body. 4 - Check the condition of the o-ring gasket on the flange. If it is worn, see to its replacement. 5 - Clean the inside of the sleeve using a clean cloth and compressed air. 6 - Remove the return spring and blow it with compressed air. Pay attention to the mounting direction of the spring, that must be placed in the same way when reassembling. 7 - Clean the complete shutter assembly with a clean cloth and compressed air. 8 - Check the sealing gasket conditions. If it is damaged, replace it. 9 - Clean the sealing disc valve seat with a clean cloth. Do not use tools that could damage it. 10 - Remove the filter and blow it with compressed air. 11 - Reassemble the valve following the sequence backwards. Malfunctioning coils must be replaced. Disconnect electric supply, remove the junction box cover. Disconnect the cables from the clamps, unscrew the fixing cap and replace the coil reassembling the valve following the sequence backwards. www.esapyronics.com 8

OVERALL DIMENSIONS - VM-L C C A B A B D1111I05 Current Standard Available Threaded Flanged A B C drawn working working Mass Model attachments attachments [mm] [mm] [mm] @230VAC pressure pressure [Kg] [W] [mbar] [mbar] VM-L0 G - 3/8-88 77 196 20 360 360 1,8 VM-L1 G - 1/2-88 77 196 20 360 360 1,8 VM-L2 G - 3/4 88 96 222 45 360 360 2,7 VM-L3 G - 1-88 96 222 45 360 360 2,7 VM-L4 G - 1.1/2-120 153 294 45/180 (*) 360 360 6,2 VM-L6 G - 2-106 156 304 45/180 (*) 360 360 6,5 VM-L72 - DN65 PN16 200 305 424 60/240 (*) 200 200/360 14,5 VM-L82 - DN80 PN16 200 305 424 60/240 (*) 200 200/360 14,5 (*) working / opening www.esapyronics.com 9

ORDERING CODE - VM-L VM-L - 01 02-03 Model 01 02 Voltage 3/8 Rp. (DN10) 1/2 Rp. (DN15) 3/4 Rp. (DN20) 1 Rp. (DN25) 1.1/2 Rp. (DN40) 2 Rp. (DN50) DN65 DN80 1 2 3 4 5 6 72 82 03 24 VDC 24 VAC +10-15% 115 VAC +10-15% 230 VAC +10-15% Limit switch (*) 24DC (*) 24 (*) 115 230 Not installed Present / K01/1 (*) on request www.esapyronics.com 10

ESA worldwide distribution AUTHORIZED DISTRIBUTION STAMP If you have any doubt about the qualifi cation or identity of the distributor, please check that they appear on our website www.esapyronics.com in the Sales Contacts section, or contact us directly at esa@esacombustion.it 2012 ESA S.p.A. Company under the management and coordination of SIAD S.p.A. All rights reserved. The information contained herein is offered for use by technically qualifi ed personnel at their discretion and risk without warranty of any kind. We regularly update our data, for updated data please visit our web site www.esapyronics.com Printed in Italy CATukR00/12 Head Office and Factory ESA S.p.A. Company under the management and coordination of SIAD S.p.A. Via E. Fermi, 40 I-24035 Curno (Bergamo) ITALY esa@esacombustion.it www.esapyronics.com Tel. +39 035 6227411 Fax +39 035 6227499 Share Capital euro 153.111,00 paid up - Fiscal Nr.: 03428410157 - V.A.T. Nr.: (IT) 00793030164 Reg. Impr. Bg Nr.: 03428410157 - R.E.A. BG-173124 - Export: BG0061150 www.esapyronics.com Pyronics International s.a. Zoning Industriel, 4ème rue B-6040 Jumet BELGIUM marketing@pyronics.be www.esapyronics.com Tel. +32 71 256970 Fax +32 71 256979