Relè di Potenza All-or-Nothing Relays designed to meet high power switching applications with up to three changeover contacts, rated 4000 or 7500 VA - AC1. They are ideally suited for arduous duties where safety and reliability are at premium, being capable of replacing small contactors switching resistive loads. The 3 mm contact gap version is very popular suiting the strictest safety standards. Now available in a wider choice of mounting options, ranging from fixing tabs to DIN-rail flange on cover or the traditional screw-mounting on base, just to suit any kind of modern application. Meeting IEC-CEI-VDE-UL-CSA standards, design includes a dust cover, 0.25" Faston terminals (6.3x0.8 mm) and flame resistant thermosetting terminal-block material. Specification Insulation resistance @ 500 VDC (all circuits) >20,000 Mohm Insulation group (VDE 110) 1 Group C - 250 VAC Pollution degree / Insulation voltage (EN 61810-1) 3 / 250 VAC Environmental protection (EN 61810-1) RT I (dust protected) Enclosure classification (EN 60529) IP 40 Mechanical life expectancy (16A types) 50 million operations (30A types) 20 million operations Electrical life expectancy (16A types) 100,000 operations (30A types) 50,000 operations Max operating frequency @ no load (AC / DC) 10,000 ops./ hour Max operating frequency @ rated load (16A types) 1,200 ops./ hour (30A types) 600 ops./ hour Surrounding ambient temperature (16A types) - 40... + 55 C (30A types) - 40... + 40 C Storage temperature - 40... + 80 C Vibration resistance (10-100 Hz) 15 g (NO) / 8 g ( NC) Shock resistance (11 ms) 13 g Minimum creepage distance / Air gap (coil-contacts) 7 / 7 mm Overvoltage class III Impulse withstand voltage peak 6 KV Type of duty continuous Minimum mounting distance 10 mm Mounting position any Environmental compatibility (European Directive 2002/95/CE) Page 1/12
Proof Voltage & Times DIELECTRIC STRENGTH Type B1-B3 Type B2-B4 OPERATING TIMES @ Rated Voltage (excluding bounces) Coil / contacts 4,000V RMS 4,000V RMS Operate max 15 milliseconds Adjacnt contacts 2,500V RMS 2,500V RMS Release max 12 milliseconds Open contacts 2,500V RMS 2,000V RMS Bounces max 10 milliseconds Ground / live parts 2,000V RMS 2,000V RMS Page 2/12
Available Types B1-1: Single pole normaly open 16A-250V AC B3-1: Single pole normaly open 30A-250V AC Open contact gap: 3 mm Weight: 135 grams Page 3/12
B1-2: Two pole normaly open 16A-250V AC B3-2: Two pole normaly open 30A-250V AC Open contact gap: 3 mm Weight: 145 grams Page 4/12
B1-3: Three pole normaly open 16A-250V AC B3-3: Three pole normaly open 30A-250V AC Open contact gap: 3 mm Weight: 155 grams Page 5/12
B2-1: Single pole changeover 16A-250V AC B4-1 : Single pole changeover 30A-250V AC Open contact gap: 1 mm Weight: 135 grams Page 6/12
B2-2: Two pole changeover 16A-250V AC B4-2: Two pole changeover 30A-250V AC Open contact gap: 1 mm Weight: 145 grams Page 7/12
B2-3: Three pole changeover 16A-250V AC B4-3: Three pole changeover 30A-250V AC Open contact gap: 1 mm Weight: 155 grams<br /> Page 8/12
Coil Data Nominal Voltage Direct Current Alternating Current Current I Resistance R (*) Current I (50Hz) Current I (60Hz) Resistance R (*) V ma ohm ma ma ohm 6 270 22 690 600 1.07 12 135 88 345 300 6.07 24 68 350 172 150 29 48 34 1400 86 75 105 60 27 2150 70 60 170 110 15 7500 38 33 550 220 7 30000 - - - 230 - - 18 16 2750 400 - - 12 10 5400 (*) Resistance values @ 23 C Tolerance on R and I: +/- 10% Supply voltages: 6-12-24-48-110-230-400 VAC (50-60Hz) / 6-12-24-48-60-110-220 VDC Rated power: 4 VA @ 50Hz (AC) / 3,6 VA @ 60Hz (AC) / 1,6 W (DC) Operating range: - 20%... + 10% (DC & AC-50Hz) / - 15%... + 10% (AC-60Hz) Minimum hold voltage: > 80% Vn (AC) / > 50% Vn (DC) Must release voltage: < 15% Vn (AC) / < 5% Vn (DC) Thermic insulation class of winding (IEC 317): F (155 C) Operating range (DC) Vs. ambient temperature Curve 1: Min. coil voltage at stabilised temperature Curve 2: Max.coil voltage at rated load VE = Operating voltage VN = Rated voltage Power variation Vs. operating voltage (AC - 50Hz) E = Operating current IN = Rated current Page 9/12
Contact Data Power rating (AC1) (type B1-B2) 4 KVA Rated voltage 250 VAC (type B3-B4) 7.5 KVA Max Voltage 400 VAC Rated current (type B1-B2) 16 A Minimum voltage 10 VAC ("Resistance only") (type B3-B4) 30 A Switching power (DC1) see diagram Max istant. current (*) (type B1-B2) 30 A Min. switched load 1000 mw (type B3-B4) 40 A Min. switched current 10 ma Single-phase motor load (**) (type B1-B2) 1/2 HP Initial resistance (***) Max. 30 milliohm (type B3-B4) 1 HP Standard material Ag90%-Ni10% (*) Maximum admitted time 0.5 seconds - ED = 0.1 (**) Cosphi 0.7-250VAC Max (***) Contact category (EN 61810-7): CC2 (1A-30V) "Only for use with suitably sized, quality external connections to avoid overheating of relay terminals." 1-600 operations per hour 2-1200 operations per hour Page 10/12
Approvals Page 11/12