Operating manual UPS - System

Similar documents
User Manual Rittal PMC UPS 6kVA

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Industrial PFC UPS System

TECHNICAL DATA SHEET KVA UPS Systemss

Ultra Sine Inverter (US) Generation 4 (G4) User Guide

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Technical Data Sheets

USER MANUAL MPS 1-5KW SERIES

Technical Data Sheets

SAVER DSP SERIES. 3-10kVA USER MANUAL

MKN-DSP SERIES - THREE PHASE

Technical data sheets

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

POWER kva

Technical Data Sheets

Technical Specification SENTINEL PRO

Technical Data Sheets

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Foreword. Manual instruction

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

EPS/ELA-Series User Manual EPS/ELA 250W

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Pulsar EXtreme 2200C / 3200C

The Ultimate UPS Security Concept

POWER kva

Phoenix Inverter

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Uninterruptible Power System

1. Important Safety Warning

PowerValue 11/31 T kva

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

.3 Section Waste Management and Disposal.

POWERTRONIX QUASAR 5-40 KVA

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

Wind Power Inverter WINDY BOY 5000A/6000A

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Start-up instructions

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Electronic Ballast EVG 2000-T

ConceptpowerTM Modular kVA

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Brake Chopper BC BC 4.1. Instruction and Operation Manual

USER MANUAL ONLINE UPS

16 37 TM INTEGRATED RADIO CONTROL INSTRUCTION MANUAL

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Master DIALOG INDUSTRY RANGE

TECHNICAL SPECIFICATIONS

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Operation Instructions

Technical Data Sheets

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

Installation and Operation Manual. RTA Series 1KVA to 3KVA Models Uninterruptible Power Systems (UPS)

Pulsar EXtreme CLA 1500C

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

Aurora Wind Interface Box

1-50 KVA SINGLE-PHASE SERVO REGULATOR INSTRUCTIONS FOR USE SERVO SINGLE-PHASE VOLTAGE REGULATOR

Informer Compact Series

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Uninterruptible Power System

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Master MPS kva kva 3:1 3:3 VFI TYPE

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Mission 1K Single Phase UPS

Technical Data Sheets

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

UPS. MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

OPERATING INSTRUCTION UPS PROTECT A. PROTECT A PROTECT A. 1400

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Three Phase UPS Systems Range: 10 to 500kVA

PURE SINE WAVE DC TO AC POWER INVERTER

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

2.7. IT system floor-standing distribution cabinet Series -IPS-F

Transcription:

Operating manual UPS - System POWERMASTER M MIL 1000VA 7Min. BAX 3330 E UPS-Division Issued 15. August 2006 JOVYATLAS JOVYATLAS Elektrische Umformtechnik GmbH Groninger Straße 29-37 D-26789 Leer/Ostfriesland P.O. Box 1580 / D-26765 Leer Tel.: 491 6002-0 Fax.: 491 6002-10 E-Mail: GL@JOVYATLAS.DE Internet: WWW.JOVYATLAS.DE

Relevant information Please read this manual thoroughly before installation. Pay attention to each relevant information especially the specific comments on the separate chapters. Careful reading will avoid malfunctions of the device later on. If there is any problem please contact our service - division.

List of contents Chapter Contents Page 1. General information 4 2. Description of the system 5 3. Description of the functions 5 4. Technical data 6 5.1 Front view POWERMASTER M series 115V 7 5.2 Back view POWERMASTER M series 115V 7 6. Electrical connection 8 6.1 Electrical Connection of the UPS-system 8 6.2 Commissioning of the UPS-system 8 6.3 Shut-down of the UPS-system 9 7. Operating and display elements for 115V - Series 10 7.1 Display of the loading of the UPS-system for 115V - Series 11 7.2 Display of the charge state of the batteries for 115V - Series 11 7.3 Handling of the panel for 115V - Series 12 8. Alarm messages for 115V - Series 13 8.1 Displayed alarm messages for 115V - Series 13 8.2 Reset of the alarm messages for 115V Series 14 8.3 Acoustical alarms and troubleshooting for 115V - Series 14 9. Remote control for 115V - Series 15 10. Maintenance 15 Operating manual POWERMASTER M MIL BAX 3330E page 3

1. General information Relevant information To prevent self discharging of the batteries you have to connect the UPS to mains and put it into operation within four weeks after receipt Attention The batteries built-in in this system are designed for the necessary bridging time at nominal load of the UPS. A no-load running operation of the UPS with a long time in battery operation could led to battery damages. This effect is determined by the technique of the battery, as the cut-off voltage will not be reached at a long discharging time. Only qualified personal is allowed to open the UPS. The connection of the UPS has to be done according to VDE considering the local rules. Don't cover the ventilation slots at backside of the UPS. Keep a distance to the surrounding walls of at least 100 mm. The UPS is built up according to protection class IP21 and has to be installed in dry and clean rooms with a surrounding temperature of 20. A lower operation temperature would decrease the autonomy time. Don't connect devices with connection-cables exceeding the length of 10 meters. This measure serves for the observance of the EMV-norm. It's not allowed to carry out structural changes on the UPS. Improper operation causes the extinction of warranty. Attention: To prevent overload or a frequent switch-over to bypass mains caused by non-sinusoidal current peeks of the connected loads you shouldn't connect laser printer, faxes or similar devices to the UPS. If it's necessary to connect such devices to the UPS, you have to choose an UPS with a higher nominal power than the maximum of the current spikes. The power semiconductors of the UPS could be immediately destroyed by the connection of loads with a half-sinusoidal rectifier. The battery isn t galvanic isolated from the mains, so it s possible that there is mains-potential at the battery-terminals Operating manual POWERMASTER M MIL BAX 3330E page 4

2. Description of the system This power supply system out of the POWERMASTER M series is an especially build ups for ship use. The ups is qualified for power supply of important consumers in ship use, such as personal computer, computercontrolled devices and similar units. The output voltage is sinusoidal. In normal operation the connected load is fed in online operation by the mains through the internal rectifier and inverter. Mains disturbances such as voltage-variations, distortions, noise etc. are filtered. The internal battery is permanently charged in a careful way by the charging rectifier in trickle charge mode 3. Description of the functions Normal operation In normal operation the battery and the inverter are fed by the rectifier (online-operation). The conversion of the AC-voltage into DC-voltage and back into AC-voltage ensures a sinusoidal output voltage with a low distortion. The DC-voltage is also necessary for the battery-charging. The inverter feeds the connected loads. Mains failure In case of mains failure the inverter is fed by the battery. At the output the output voltage of the inverter is still available. Inverter failure or overload In case of inverter failure or overload the load is switched back to the mains. In case of mains failure the consumers are not supplied in that case any longer. Operating manual POWERMASTER M MIL BAX 3330E page 5

4. Technical data POWERMASTER S 1000-7-115 Input Voltage 115V (80V... 138V) Input power factor cos φ: 0,98 Frequency 50 / 60 ±5 Current at 115V 12,4A Required fuse C20A C-Automatic Battery voltage 36V Output power 1000VA Affective power 700W Efficency 85 Output voltage 115V (sinuswave) Output power factor cos φ: 0,7 Frequency 50 / 60 ±0.5 Distorsion < 3 (at linear Load) Overload capability >105 for 10s /> 130 for 300ms Crest Factor 3 : 1 Operation mode Online Signalisation Data processing interface Radio interferance Acc. EN 50091-2 : 1994 Klasse B degree According to the rules CE, EN, IEC, VDE of Loudness < 45 dba Temperature 0... 55 If temperature is exceeding 55 the ups will switch to bypass, the load is now not buffered by battery Humidity Max. 95 non condensing Dimension (mm) Width Height Depth 483 (19-Inch) 131 404 Weight (kg) (incl. Battery) 22 Operating manual POWERMASTER M MIL BAX 3330E page 6

5.1 Front view POWERMASTER M series 115V 483 131 technical modifications are possible 5.2 Back view POWERMASTER M series 115V Attention in this case the main input plug and the load output plug are modified in that way that there are special input socket and output socket are used on the rear side of the ups. Operating manual POWERMASTER M MIL BAX 3330E page 7

6. Electrical connection Attention Only qualified personnel is allowed to work on the UPS-system. The respective safety regulations have to be considered. The labeling of the conductors has to be made according DIN40705,2.80 and DIN- EN60445,09.91 Ensure a sufficient dimensioning of the protective conductor connection Attention During works on the battery dangerous situations may arise caused by the high dc-voltage and the high short circuit currents. Therefore works on the system may be carried out only by using suited protective measures, such as insulated tools, face- and hands protection and so on. 6.1 Electrical Connection of the UPS-system At the UPS-system POWERMASTER M 1000 all connections are located on the rear side of the ups and are fixed. 6.2 Commissioning of the UPS-system The mains input has to be connected to plug U9:B1 at the rear of the UPS and the load has to be connected to plug U9:B3.The communication cable has to be connected to plug U9:B2. The ups starts only by connecting the ups to the mains and switching on the ON button at the front of the ups, for 2 seconds continuously. In case of a lightening bar graph at the battery display you have to press down the mains switch ON for 2 seconds. ONLY FOR 115V SERIES: After a short initialization of approx. 5 sec. the following LED's are lightening: (input mains) BYPASS (direct bypass onto the input mains) (load of the UPS in ) ERY (battery state in ) After approx. 5 seconds further on the announcement (inverter) appears. The signal BYPASS goes out. The consumer plug backsides the UPS is fed by the inverter now. For controlling its correct functioning, disconnect the UPS from the mains, but don t switch it off. Now the message extinguishes and the messages and are lightening. Operating manual POWERMASTER M MIL BAX 3330E page 8

The consumer plug is fed by the inverter which is supplied by the battery. As soon as you `ll connect the UPS to the mains again, the messages and will lighten up again and the -announcement goes out. Attention After controlling the correct operation of all functions the UPS is ready for servicing the connected consumers Now you can connect the consumers which have to be powered onto the consumer plug at the rear of the UPS. After that switch-on the UPS and wait until the inverter () has switched-on again. After that you have to switch-on the consumers. During the connection of devices with fans or transformers, it is possible that the UPS switches over onto bypass-operation BYPASS because of the high initial currents of the connected loads. That s a normal occurrng, the UPS gets back to inverter operation after a few seconds. If you recognize deviations please contact us ( see also page 2). 6.3 Shut-down of the UPS-system To switch off the UPS, please press the off button in front of the ups, the ups will be initialized again and the message 8888 is shown in the display, the load is still supplied by the ups. To switch-off the complete UPS, please switch off the mains. For the system POWERMASTER M 1000 you have to switch-off the mains voltage. After that you have to press down the mains switch of the UPS OFF. Operating manual POWERMASTER M MIL BAX 3330E page 9

7. Operating and display elements for 115V - Series 8 9 10 11 12 13 14 1 2 3 4 5 6 7 888 8. ON OFF SELECT 16 15 position display Function of the display 1 Input mains is connected 2 BYPASS Overloaded UPS 3 Inverter operation (normal operation) 4 Autonomy operation 5 UPS failure fault signal shown at the display 6 state of battery charge 7 Loading of the UPS-system 8 888.8 Digital display of the data 9 I/P Display in connection with the input data 10 O/P Display in connection with the output data 11 Display in connection with the input/ output voltage 12 Display in connection with the input/ output frequency 13 Temperature of the UPS system 14 ON Switch-on of the UPS-system 15 OFF Switch-off the UPS-system 16 SELECT Selector switch of the functions Technical deviations may occurr Operating manual POWERMASTER M MIL BAX 3330E page 10

7.1 Display of the loading of the UPS-system for 115V - Series The display of the UPS shows the actual state of the loading. The loading is shown through five segments. 888 8. 1. loading of the UPS amounts to 0-20 2. loading of the UPS amounts to 21-40 3. loading of the UPS amounts to 41-60 4. loading of the UPS amounts to 61-80 5. loading of the UPS amounts to 81-100 Relevant information The interval cheeping sound and blinking of the loading display are the indication for overloading of the UPS. The UPS switches off automatically onto bypass operation 7.2 Display of the charge state of the batteries for 115V - Series At the display of the UPS the actual charge state of the system is shown through a segment display 888 8. 1. loading of the battery amounts to 0-20 2. loading of the battery amounts to 21-40 3. loading of the battery amounts to 41-60 4. loading of the battery amounts to 61-80 5. loading of the battery amounts to 81-100 Operating manual POWERMASTER M MIL BAX 3330E page 11

7.3 Handling of the panel for 115V - Series By pressing the SELECT push button the actual Input and output parameters were displayed. For a display of the different parameters one after another you have to press down the push button SELECT durably. You ve to release the push button SELECT when the display shows the parameter you ve asked for. The following input and output parameters can be displayed. 1. Output voltage 115V 115. 0 2. input voltage normally: 1 x 115V tolerance: 80V - 138V 107. 6 critical range: <138V 3. input frequency normally: 50 or 60 ±3 critical range: <37,5 / >82,5 50. 7 4. output frequency normal: 50 or 60 ±3 50. 0 5. Temperature The temperature is dependent on the loading and on the surrounding temperature of the UPS-system. Critical range: > 55 In this case the ups will switch to bypass the load isn t buffered by the ups until the temperatue will be less then 55. 26. 3 Operating manual POWERMASTER M MIL BAX 3330E page 12

8. Alarm messages for 115V - Series 8.1 Displayed alarm messages for 115V - Series The display of the UPS is designed to send out 7 messages. Attention These alarm messages can t be reset without a complete switch-off of the UPS-system. Please contact our service department in case of alarms like these. E01 : Inverter failure The alarm Message E01 will be shown at the display and the connected load is supplied through the internal bypass further on. E02 : Overtemperature The alarm E02 will be shown at the display and the connected load is supplied through the internal bypass further on. E01 E02 E03 : Short circuit on the part of the output In case of this fault the UPS-system switches off immediately. The existing load won t be supplied any longer. The alarm message E03 will be shown at the display E04 : Overloading of the UPS-system The alarm E04 will be shown at the display and the connected load is supplied through the internal bypass further on. E05 : Misvoltage (>400VDC) on the part of the d.c.voltage The alarm E05 will be shown at the display and the connected load is supplied through the internal bypass further on. E06 : Misvoltage of the battery (voltage higher than 280VDC) The alarm E06 will be shown at the display and the connected load is supplied through the internal bypass further on. E07 : Battery voltage is too high or too low The alarm E07 will be shown at the display and the connected load is supplied through the internal bypass further on E03 E04 E05 E06 E07 Operating manual POWERMASTER M MIL BAX 3330E page 13

8.2 Reset of the alarm messages for 115V Series The alarm messages can t be reset without switching off the UPS-system completely. - Switch off the complete load at the consumer distribution pole of the UPS. Attention High relevant devices and so on won t be supplied further on. If it s still necessary to supply them by the UPS, there has to be installed an external bypass to feed the loads during a failure or servicing of the UPS further on. - Switch off the UPS-systems POWERMASTER M 1000 through removing the input mains of the device. Than you have to press down the push button OFF in front of the display for 2 seconds. After a delay of 5 seconds the UPS-system will switch-off completely. - In case of no success please contact our service-department. 8.3 Acoustical alarms (deactivated) and troubleshooting for 115V - Series The symbol at the display is out and the symbols and are lightening. - Failure of the mains (input mains of the UPS-system) Measure: Check the line from the terminals to the UPS-system and control the mains fuses of the domestic installation - The symbol is out, the symbol BYPASS is on and the load indication is flashing: The UPS is overloaded. Measure: Decrease the loading of the UPS-system by switching-off separate consumers. Attention To protect the batteries the UPS-system switches-off at the moment the adjusted battery cut-off voltage is reached. Thereby the system is completely released. In case of mains returning the UPSsystem returns automatically into the normal operation state. Operating manual POWERMASTER M MIL BAX 3330E page 14

9. Remote control for 115V - Series The UPS possesses a signal output at the rear side of the ups. The serial interface serves to the data transfer between a PC and the UPS. Even the inspection of the UPS can be done by PC. In case of mains failure the switch-off of the UPS is possible. Pin holding of the data transfer interface PIN Description of the function input / output Contact rating A Reference earth for PIN B C output TTL Logic B RS 232 data output TX output TTL Logic C Remote shutdown RX output TTL Logic D Battery low, Battery discharged input TTL Logic E Mains failure input TTL Logic F Reference earth for PIN D E (RTN) input TTL - Logic Technical deviations are possible 10. Maintenance In case of longer standstill of the UPS (>= 4 weeks) the battery has to be charged monthly. For this charging you only have to connect the UPS to the mains for a charging time of at least 8 hours. However we recommend a charging time for about 24 hours. The battery in its standard version is maintenance-free. Please note the hints of the battery-manufacturer in case of using a special battery. The ventilation slot at the backside of the UPS has to be clean, without any dust or something soiling to prevent a reduced air-exchange. Please observe the necessary distance to surrounding walls of at least 100 mm. Half a year you have to check up the perfect function of the UPS. Therefore you have to disconnect the UPS from the mains with connected load / consumers. We recommend the use of a remote control system in case of UPS systems which can t be controlled directly. Operating manual POWERMASTER M MIL BAX 3330E page 15