ABB France 3 rue Jean Perrin CS CHASSIEU Cedex FRANCE. Eppelheimer Str HEIDELBERG - ALLEMAGNE. Contacteur Contactor

Similar documents
AF40... AF96 3-pole contactors Technical data

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

For Info: Phone: Fax:

K50H004UP cam changeover switch - 4-pole A - screw mounting

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

K30H001YP cam star-delta switch - 3-pole A - screw mounting

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Modular contactors and relays

C E R T I F I C A T E O F C O M P L I A N C E

VD Range Gamme VD. 100% electronic voltage detector. Détecteur de tension 100% électronique. Technical argumentation. Argumentation technique

Mini contactors B6, BC6 with 3 pole

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

3 - Protection components Motor circuit-breakers

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Thermal overload relay TF140DU and TF140DU-V1000

DRX 125 Circuit breaker (not adjustable)

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Industrial contactors CTX-1

Industrial Contactors CTX 3 3P 185A - 800A

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

K63F003UP cam changeover switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting


Limit Switch - Prewired Type Metal Body

Thermal overload relay TF65 and TF96

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

HBO Range Gamme HBO. Hall effect open-loop current sensors. Capteurs de courant à effet Hall boucle-ouverte. Technical argumentation

MANUALLY OPERATED CHANGEOVER SWITCHES

Selective main circuit breakers S 750 series Technical Data

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

Cylindrical fuse-link

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

CERTIFICAT ROBINETTERIE SANITAIRE. Decision d'admission du 2eme semestre 1986 Decision de reconduction no 334-M1-08/3 du 24 novembre 2008

INTERNATIONAL STANDARD

Limit Switches - Limit Type (PS21L) Metal Body IP66

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

DPX Magnetic only

XACA871 pendant control station XAC-A - 8 pushbuttons

ASL09..S 3-pole Contactors - Spring Terminals

Enclosed Starters. Contents. Motor nominal powers and current... 20/2. Panorama... 20/3. Starting of three-phase asynchronous motors...

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Vistop TM isolating switches 63 to 160A

DPX 1600 Electronic release

DX³ RCBO 6000A Phase + Neutral, neutral on right

Position switches FD series

Cylindrical fuse-link

(English language translation, the original version is in French language) PFG expansion bolt type LB, ES and SB

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

Modular contactor for installation into distribution boards

Essential equipment for all your requirements

An innovative technology

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

DRX 100 B/N/H Circuit breaker (not adjustable)

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Safety rope switches with reset for emergency stop

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

XACA871 pendant control station XAC-A - 8 pushbuttons

Meta Solution. Contactors and Overload relays

VersaWall SlimLine 1750

Solid Clamps Raccords orientables

Limit Switches - Limit Type Plastic Body IP65

Compact plastic limit switches with positive opening mechanism

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

DBL distribution blocks 3x1 pole

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

(English language translation, the original version is in French language) FM 753

Manual Motor Starters. Meta-MEC

VS Range Gamme VS. 100% electronic voltage sensors. Capteurs de tension 100% électronique. Technical argumentation. Argumentation technique

Limit Switches - Limit Type Plastic Body IP65

Motorized switch-disconnectors OTM 40 to 125 Amperes

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DRX 250 B/N/H Circuit breaker (not adjustable)

AE 9... AE 40 Contactors NE... Contactor Relays

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Manual motor starter MS132

Limit Switches - Limit Type (PS31L) Plastic Body IP65

up to 63 A (1 module per pole)

Fan Relay Board (FRBii) Assembly

Compact plastic limit switches with positive opening mechanism

Transcription:

LCIE N : Titulaire : License Holder: Site de fabrication : Factory: ABB France 3 rue Jean Perrin CS 90009 69687 CHASSIEU Cedex FRANCE ABB STOTZ KONTAKT GmbH Eppelheimer Str. 82 69123 HEIDELBERG - ALLEMAGNE ABB Bulgaria EOOD, Rakovski Branch Plot 28, Industrial Zone 4150 RAKOVSKI, PLOVDIV - BULGARIE (N 1165AP) (N 1906AP) Produit : Product: Contacteur Contactor Marque commerciale (s'il y a lieu) : Trade mark (if any): Modèle, type, référence : Model, type, reference: Caractéristiques principales : Main characteristics: Informations complémentaires : Additional information: Le produit est conforme à : The product is in conformity with: ESB16-20N, EN20-20N, ESB20-20N Voir Annexe / See Annex Voir Annexe / See Annex / EN 61095:2009 Documents pris en compte : Relevant documents: Annule et remplace (s'il y a lieu) : Cancels and replaces (if necessary): Rapport(s) d'essai(s) / Test report(s) n CBTC n CN42939 / TR 00901CB2017CQC-078401, 00901CB2017CQC-078402 / En vertu de la présente décision notifiée par le LCIE organisme mandaté, AFNOR Certification accorde le droit d'usage de la Marque NF à la société qui en est titulaire pour les produits visés ci-dessus, dans les conditions définies par les règles générales de la Marque NF et par les règles de certification NF, pour autant que les contrôles réguliers de la fabrication et les vérifications par tierce partie soient satisfaisants. Fontenay-aux-Roses, 09/07/2018 Date de fin de validité / Expiry date : La validité de la présente licence cesse dès l'annulation de l'une des normes sur lesquelles elle est fondée. The present license is valid until the cancellation of one of the standards on which it is based. On the strength of the present decision notified by LCIE mandated certification body, AFNOR Certification grants the right to use the NF Mark to the licence holder for the above mentioned products, within the frame of the general rules of the NF Mark and of the NF certification rules, as far as the regular checking and third party verifications of the production are satisfactory. Didier BOURGES Responsable des Opérations Certification / Manager of Certification Operations

RÉFÉRENCES - CARACTÉRISTIQUES PRINCIPALES / REFERENCES - MAIN CHARACTERISTICS Référence / Reference EN20-20N Circuit principal / Main-circuit Nombre de pôles / Number of poles : 2 Mode de commande / Method of control : Automatic Semi-automatic Tension assignée d emploi / Rated operational voltage Ue : (V) 220 Vdc; 250 Vac Tension assignée d isolement / Rated insulation voltage Ui : (V) 400 V Tension assignée de tenue aux chocs / Rated impulse withstand voltage Uimp : (V) 6000 V Courant thermique conventionnel à l air libre / Conventional free air thermal current Ith : (A) 20 A Courant thermique conventionnel sous enveloppe / Conventional enclosed thermal current Ith : (A) 20 A Courant assigné d emploi / Rated operational current Ie : (A) AC-7a: 20 A AC-7b: 9 A Puissances assignées d emploi / Rated operational powers AC-7a: (230 V, 1~) : 4,6 kw AC-7b: (230 V, 1~) : 1,3 kw DC, 50 Hz, 60 Hz Service assigné / Rated duties : Continuous duty (Eight-hour duty) Catégorie d emploi / Utilization category : AC-7a / AC-7b Courant assigné de court-circuit conditionnel / Rated conditional short-circuit current Iq : (A) 10 ka Dispositif de protection contre les courts-circuits / Details of short-circuit protective devices SCPD to used : 20 A, gg Type fuses s Nature du courant / Nature of supply AC/DC DC, 50 Hz, 60 Hz, 400 Hz Tension assignée / Rated control circuit voltage Uc : (V) 24 V, 230 V Aptitude au raccordement TBTS / Suitability to be connected to SELV circuits No Classe de la matière isolante de la bobine / Class of insulating material for insulated coils F Circuits auxiliaires / Auxiliary circuits Nombre de circuits / Number of circuits 0 Nombre de contacts / Number of contacts 0 Installation Enveloppe / Enclosure Intended for use within an enclosure Degré de protection / Protection degree : IP20 Degré de pollution / Pollution degree 3 Groupe de matériau / Material group (IRC / CTI) II / IIIa Page 2/7

Manifestations extérieures en conditions de court-circuit / External phenomena under short-circuit conditions Détail écran métallique / Details of the wire-mesh Mode de commande / Operating means Sans / Without Raccordement des conducteurs externes / Connection for external conductors Type de bornes / Type of terminals : Diamètre des vis des bornes / Nominal diameter of thread : (mm) Couple de serrage / Tightening torque (Nm) Capacité de raccordement / Connecting capacity Section min. - nombre de conducteurs / number of conductors Section max. nombre de conducteurs / number of conductors Section min. - nombre de conducteurs / number of conductors Section max. - nombre de conducteurs / number of conductors Wire-mesh size : length: 50mm, diameter: 0,8mm Distance between contactor and wire-mesh : 75mm Lever / Insulating material Screw 4 mm 3 mm 1,2 Nm 0,9 Nm 1 mm² - 1x / 2x 10 mm² / 4 mm² - 1x / 2x 1 mm² / 4mm² - 2x 0,5 mm² / 0,75 mm² - 1x / 2x 4 mm² / 2,5 mm² - 1x / 2x 0,75 mm² / 1,5mm² - 2x Page 3/7

Référence / Reference ESB20-20N Circuit principal / Main-circuit Nombre de pôles / Number of poles : 2 Mode de commande / Method of control : Automatic Tension assignée d emploi / Rated operational voltage Ue : (V) 220 Vdc; 250 Vac Tension assignée d isolement / Rated insulation voltage Ui : (V) 400 V Tension assignée de tenue aux chocs / Rated impulse withstand voltage Uimp : (V) 6000 V Courant thermique conventionnel à l air libre / Conventional free air thermal current Ith : (A) 20 A Courant thermique conventionnel sous enveloppe / Conventional enclosed thermal current Ith : (A) 20 A Courant assigné d emploi / Rated operational current Ie : (A) AC-7a: 20 A AC-7b: 9 A Puissances assignées d emploi / Rated operational powers AC-7a: (230 V, 1~) : 4,6 kw AC-7b: (230 V, 1~) : 1,3 kw DC, 50 Hz, 60 Hz Service assigné / Rated duties : Continuous duty (Eight-hour duty) Catégorie d emploi / Utilization category : AC-7a / AC-7b Courant assigné de court-circuit conditionnel / Rated conditional short-circuit current Iq : (A) 10 ka Dispositif de protection contre les courts-circuits / Details of short-circuit protective devices SCPD to used : 20 A, gg Type fuses s Nature du courant / Nature of supply AC/DC DC, 50 Hz, 60 Hz, 400 Hz Tension assignée / Rated control circuit voltage Uc : (V) 24 V, 230 V Aptitude au raccordement TBTS / Suitability to be connected to SELV circuits No Classe de la matière isolante de la bobine / Class of insulating material for insulated coils F Circuits auxiliaires / Auxiliary circuits Nombre de circuits / Number of circuits 0 Nombre de contacts / Number of contacts 0 Installation Enveloppe / Enclosure Intended for use within an enclosure Degré de protection / Protection degree : IP20 Degré de pollution / Pollution degree 3 Groupe de matériau / Material group (IRC / CTI) II / IIIa Page 4/7

Manifestations extérieures en conditions de court-circuit / External phenomena under short-circuit conditions Détail écran métallique / Details of the wire-mesh Mode de commande / Operating means Sans / Without Raccordement des conducteurs externes / Connection for external conductors Type de bornes / Type of terminals : Diamètre des vis des bornes / Nominal diameter of thread : (mm) Couple de serrage / Tightening torque (Nm) Capacité de raccordement / Connecting capacity Section min. - nombre de conducteurs / number of conductors Section max. nombre de conducteurs / number of conductors Section min. - nombre de conducteurs / number of conductors Section max. - nombre de conducteurs / number of conductors Wire-mesh size : length: 50mm, diameter: 0,8mm Distance between contactor and wire-mesh : 75mm Lever Screw 4 mm 3 mm 1,2 Nm 0,9 Nm 1 mm² - 1x / 2x 10 mm² / 4 mm² - 1x / 2x 1 mm² / 4mm² - 2x 0,5 mm² / 0,75 mm² - 1x / 2x 4 mm² / 2,5 mm² - 1x / 2x 0,75 mm² / 1,5mm² - 2x Page 5/7

Référence / Reference ESB16-20N Circuit principal / Main-circuit Nombre de pôles / Number of poles : 2 Mode de commande / Method of control : Automatic Tension assignée d emploi / Rated operational voltage Ue : (V) 220 Vdc; 250 Vac Tension assignée d isolement / Rated insulation voltage Ui : (V) 400 V Tension assignée de tenue aux chocs / Rated impulse withstand voltage Uimp : (V) 6000 V Courant thermique conventionnel à l air libre / Conventional free air thermal current Ith : (A) 16 A Courant thermique conventionnel sous enveloppe / Conventional enclosed thermal current Ith : (A) 16 A Courant assigné d emploi / Rated operational current Ie : (A) AC-7a: 16 A AC-7b: 6 A Puissances assignées d emploi / Rated operational powers AC-7a: (230 V, 1~) : 3,68 kw AC-7b: (230 V, 1~) : 0,85 kw DC, 50 Hz, 60 Hz Service assigné / Rated duties : Continuous duty (Eight-hour duty) Catégorie d emploi / Utilization category : AC-7a / AC-7b Courant assigné de court-circuit conditionnel / Rated conditional short-circuit current Iq : (A) 10 ka Dispositif de protection contre les courts-circuits / Details of short-circuit protective devices SCPD to used : 20 A, gg Type fuses s Nature du courant / Nature of supply AC/DC DC, 50 Hz, 60 Hz, 400 Hz Tension assignée / Rated control circuit voltage Uc : (V) 24 V, 230 V Aptitude au raccordement TBTS / Suitability to be connected to SELV circuits No Classe de la matière isolante de la bobine / Class of insulating material for insulated coils F Circuits auxiliaires / Auxiliary circuits Nombre de circuits / Number of circuits 0 Nombre de contacts / Number of contacts 0 Installation Enveloppe / Enclosure Intended for use within an enclosure Degré de protection / Protection degree : IP20 Degré de pollution / Pollution degree 3 Groupe de matériau / Material group (IRC / CTI) II / IIIa Page 6/7

Manifestations extérieures en conditions de court-circuit / External phenomena under short-circuit conditions Détail écran métallique / Details of the wire-mesh Mode de commande / Operating means Sans / Without Raccordement des conducteurs externes / Connection for external conductors Type de bornes / Type of terminals : Diamètre des vis des bornes / Nominal diameter of thread : (mm) Couple de serrage / Tightening torque (Nm) Capacité de raccordement / Connecting capacity Section min. - nombre de conducteurs / number of conductors Section max. nombre de conducteurs / number of conductors Section min. - nombre de conducteurs / number of conductors Section max. - nombre de conducteurs / number of conductors Wire-mesh size : length: 50mm, diameter: 0,8mm Distance between contactor and wire-mesh : 75mm Lever Screw 4 mm 3 mm 1,2 Nm 0,9 Nm 1 mm² - 1x / 2x 10 mm² / 4 mm² - 1x / 2x 1 mm² / 4mm² - 2x 0,5 mm² / 0,75 mm² - 1x / 2x 4 mm² / 2,5 mm² - 1x / 2x 0,75 mm² / 1,5mm² - 2x Page 7/7