Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.) Model

Similar documents
A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

A165E CSM_A165E_DS_E_11_2

A L - J R M - 24D - 2

M T R - 24D - P

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

D4BS CSM_D4BS_DS_E_8_4

G3PE-Single-phase. Solid State Relays for Heaters

D4GS-N CSM_D4GS-N_DS_E_7_2

A3S. Pushbutton Switch Series with Square 40-mm Body. Lighted Pushbutton Switch (Square) List of Models

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

A22E. Emergency Stop Switch (22-dia./25-dia.) Install in 22-dia. or 25-dia. Panel Cutout. Model Number Structure L M 24A 01

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

2NC (slow-action) Direct. Model. opening

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4.

Model Number Structure

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models

2NC (slow-action) Direct. Model. opening

A22LK CSM_A22LK_DS_E_6_2

A22. Install in 22-dia. or 25-dia. Panel Cutout (When Using a Ring) Pushbutton Switch (Cylindrical 22/25-dia.) List of Models

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

D4BL. Guard Lock Safety-door Switch

D4NH CSM_D4NH_DS_E_7_1

DIN Track Terminal Blocks with Screw Terminals XW5T

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

S8JX-N/S8JX-G Series Replacement Brackets

DIN Track Terminal Blocks with Screw Terminals XW5T

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

DIN Track Terminal Blocks with Screw Terminals

CSM_D4N-_R_DS_E_6_1

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Multiple Limit Switch

Better Productivity by Standstill and Low-speed Monitoring

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Dimension A. Dimension B

A22/M22. Specifications. Specifications Common to All. Complete Assemblies

Lighted Pushbutton Switch

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

A4EG CSM_A4EG_DS_E_6_1

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

Digital display Pressure range ON/OFF output Linear output Model

Safety Limit Switch

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) A22E/A22NE-P

Safety Guard Switching Unit G9SX-GS

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

Pushbutton Switches 30-mm Pushbutton Switches Universal Design. Emphasis on Color Coding, Workability, and Safety.

D4BL. Guard Lock Safety-door Switch

A16/M16. Ordering Information. Pushbutton Switches/Pilot Lights. Complete Assemblies. Mounting Aperture of 16 mm. H Modular construction (Pushbutton +

Lighted PushButton Switch

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

D4NS/D4NS-SK. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Nextgeneration. Model Number Structure. Model Number Legend

A22E. Model Number Structure. Emergency Stop Switch. Model Number Legend. Completely Assembled. Install in 22-dia. or 25-dia.

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

Subminiature Basic Switch

Redundancy Unit. Model Number Structure. Ordering Information. Model Number Legend. New Product. S8VK-R Series name

Safety Limit Switch

A22TK Key-type Selector Switch with Direct Opening Mechanism

1,000 M min. (at 500 VDC)

Miniature Limit Switches

Mechanical Key Switch

Small Limit Switch D4V

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Safety Interlock Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

A22NK. Key-type Selector Switches

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

A22E. Model Number Structure. Emergency Stop Switch. Model Number Legend. Completely Assembled. Install in 22-dia. or 25-dia.

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Model Number Structure

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Bright illumination face and snap-action switching.

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

A22E. Emergency Stop Switch (22-dia./25-dia.) Install in 22-dia. or 25-dia. Panel Cutout. Model Number Structure L M 24A 01

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

Safety Interlock Switches

Best-selling Basic Switch Boasting High Precision and Wide Variety

Small-diameter Proximity Sensor

D4NL CSM_D4NL_DS_E_9_2

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

ø8 A8 Series Miniature Control Units

EStrong-series Emergency Stop

A22TK Key-type Selector Switch with Direct Opening Mechanism

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Pushbutton Switches/Indicators A22R/M22R series. Robust and Graceful design. Pushbutton Switches. Push Button. Secure and Human-centered

Safety-door Switch. Ordering Information

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Transcription:

Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.) CSM DS_E_11_2 Separate Construction with Cylindrical 16-dia. Body Miniature design of 28.5 mm, the smallest class in the industry. Detachable Switch. The same contacts can be used for both standard loads and microloads. Easy-to-wire terminal arrangement. Certified for EN 60947-5-1. Refer to Safety Precautions for All Pushbutton Switches/ Indicators and Safety Precautions on page 24. List of Models Model Square Round Solder terminals @-J Series @-A Series @-T Series PCB terminals @-J Series @-A Series @-T Series Voltage-reduction lighting solder terminals @-J Series @-A Series @-T Series Screw-less clamp models @-J Series @-A Series @-T Series Button Colors The button colors when the buttons are lit and when they are not lit are shown below. Use these colors as reference only. The actual colors may vary. When not lit When lit R (Red) Y (Yellow) PY (Pure yellow) G (Green) W (White) A (Blue) PW (Pure white) B (Black) 1

Model Number Structure Model Number Legend... The model numbers used to order sets of Units are illustrated below. One set comprises the Pushbutton, Lamp (lighted models only), Case, and Switch. For information on combinations, refer to Ordering Information on pages 3 to 7. (1) (2) (3) (4) (5) (6) (7) A 1 6 5 L - J R M - 24 D - 2 (1) Degree of Protection Symbol No symbol 5 Protection Oil-resistant IP66 (2) Lighted/ Symbol No symbol L Type Lighted (3) Shape of Pushbutton Symbol J A T (7) Contact Configuration Symbol 1 2 1P 2P 2S Type Terminal Solder Terminal PCB Terminal Screw-less Clamp Only contacts are available with ScrewLess Clamp. Consult your OMRON representative concerning pricing and delivery timing for PCB terminals and screw-less clamp connectors. Shape (6) Light Source Rectan2-way guard gular (5) Switch Operation Operating Rated Symbol Type voltage voltage Square 2-way guard Symbol Operation (4) Color of Pushbutton No symbol Projecting Round Momentary M model Symbol Color 5 6 VAC/VDC IncanA Alternate R Red descent 14 VAC/VDC 12 Momentary-operation: lamp Y Yellow 24 28 VAC/VDC Self-resetting Pure yellow PY 5D 5 ± 5% VDC Alternate-operation: G Green 12 ± 5% Self-holding 12D VAC/VDC W White 24 ± 5% A Blue Colored Illumination 24D VAC/VDC PW Pure white Unlit Lit Voltage Reduction Unit (24-V Built-in ) Black (non-lighted White Color B models only) Operating Rated The built-in Symbol Type Color illuminated models are also voltage voltage is colored. available (see page 8). 100 to 110 100/110 Order the parts separately. T1 VAC/VDC VAC/VDC 200 to 220 200/220 T2 VAC/VDC VAC/VDC Solder terminals are available only with 100-V models. The Voltage Reduction Unit is not available for models with PCB terminals. T2 is available only for the Screw-less Clamp type. 2

Ordering Information Ordering as a Set... The model numbers used to order sets of Units are given in the following tables. One set comprises the Pushbutton, Lamp (lighted models only), Case, and Switch. Solder Terminal Models Models @-J Item Output Lighting without Voltage Reduction Unit Incandescent lamp Operating voltage Incandescent lamp Alternate operation (Self-holding) L-J@M-5D-1 L-J@A-5D-1 L-J@M-12D-1 L-J@A-12D-1 L-J@M-24D-1 L-J@A-24D-1 L-J@M-5-1 L-J@A-5-1 L-J@M-12-1 L-J@A-12-1 L-J@M-24-1 L-J@A-24-1 -J@M-1 -J@A-1 L-J@M-5D-2 L-J@A-5D-2 L-J@M-12D-2 L-J@A-12D-2 L-J@M-24D-2 L-J@A-24D-2 L-J@M-5-2 L-J@A-5-2 L-J@M-12-2 L-J@A-12-2 L-J@M-24-2 L-J@A-24-2 -J@M-2 -J@A-2 without Voltage Reduction Unit Momentary operation (Self-resetting) Pushbutton color symbol *1 G: green, W: white G: green, W: white *1. Enter the desired color symbol for the Pushbutton in the @. *2. Black ( B ) Pushbuttons are only available for non-lighted models. Oil-resistant IP66 Item Output Lighting without Voltage Reduction Unit Incandescent lamp Operating voltage Incandescent lamp Alternate operation (Self-holding) 5L-J@M-5D-1 5L-J@A-5D-1 5L-J@M-12D-1 5L-J@A-12D-1 5L-J@M-24D-1 5L-J@A-24D-1 5L-J@M-5-1 5L-J@A-5-1 5L-J@M-12-1 5L-J@A-12-1 5L-J@M-24-1 5L-J@A-24-1 5-J@M-1 5-J@A-1 5L-J@M-5D-2 5L-J@A-5D-2 5L-J@M-12D-2 5L-J@A-12D-2 5L-J@M-24D-2 5L-J@A-24D-2 5L-J@M-5-2 5L-J@A-5-2 5L-J@M-12-2 5L-J@A-12-2 5L-J@M-24-2 5L-J@A-24-2 5-J@M-2 5-J@A-2 without Voltage Reduction Unit Momentary operation (Self-resetting) Pushbutton color symbol *1 G: green, W: white G: green, W: white *1. Enter the desired color symbol for the Pushbutton in the @. *2. Black ( B ) Pushbuttons are only available for non-lighted models. Individual models: Refer to pages 9 to 13. Ratings: Refer to page 16. Characteristics: Refer to page 16. (The Pushbutton, Lamp, Case, and Switch can be ordered Accessories: Refer to page 15. separately.) 3

Ordering Information Ordering as a Set... The model numbers used to order sets of Units are given in the following tables. One set comprises the Pushbutton, Lamp (lighted models only), Case, and Switch. Solder Terminal Models Square Models @-A Item Output Lighting without Voltage Reduction Unit Incandescent lamp Operating voltage Incandescent lamp Alternate operation (Self-holding) L-A@M-5D-1 L-A@A-5D-1 L-A@M-12D-1 L-A@A-12D-1 L-A@M-24D-1 L-A@A-24D-1 L-A@M-5-1 L-A@A-5-1 L-A@M-12-1 L-A@A-12-1 L-A@M-24-1 L-A@A-24-1 -A@M-1 -A@A-1 L-A@M-5D-2 L-A@A-5D-2 L-A@M-12D-2 L-A@A-12D-2 L-A@M-24D-2 L-A@A-24D-2 L-A@M-5-2 L-A@A-5-2 L-A@M-12-2 L-A@A-12-2 L-A@M-24-2 L-A@A-24-2 -A@M-2 -A@A-2 without Voltage Reduction Unit Momentary operation (Self-resetting) Pushbutton color symbol *1 G: green, W: white G: green, W: white *1. Enter the desired color symbol for the Pushbutton in the @. *2. Black ( B ) Pushbuttons are only available for non-lighted models. Oil-resistant IP66 Item Output Lighting without Voltage Reduction Unit Incandescent lamp Operating voltage Incandescent lamp Alternate operation (Self-holding) 5L-A@M-5D-1 5L-A@A-5D-1 5L-A@M-12D-1 5L-A@A-12D-1 5L-A@M-24D-1 5L-A@A-24D-1 5L-A@M-5-1 5L-A@A-5-1 5L-A@M-12-1 5L-A@A-12-1 5L-A@M-24-1 5L-A@A-24-1 without Voltage Reduction Unit Momentary operation (Self-resetting) 5-A@M-1 5-A@A-1 5L-A@M-5D-2 5L-A@A-5D-2 5L-A@M-12D-2 5L-A@A-12D-2 5L-A@M-24D-2 5L-A@A-24D-2 5L-A@M-5-2 5L-A@A-5-2 5L-A@M-12-2 5L-A@A-12-2 5L-A@M-24-2 5L-A@A-24-2 5-A@M-2 5-A@A-2 Pushbutton color symbol *1 G: green, W: white G: green, W: white *1. Enter the desired color symbol for the Pushbutton in the @. *2. Black ( B ) Pushbuttons are only available for non-lighted models. Individual models: Refer to pages 9 to 13. (The Pushbutton, Lamp, Case, and Switch can be ordered Ratings: Refer to page 16. Characteristics: Refer to page 16. Accessories: Refer to page 15. separately.) 4

Ordering Information Ordering as a Set... The model numbers used to order sets of Units are given in the following tables. One set comprises the Pushbutton, Lamp (lighted models only), Case, and Switch. Solder Terminals Round Models @-T Item Output Lighting without Voltage Reduction Unit Incandescent lamp Operating voltage Incandescent lamp Alternate operation (Self-holding) L-T@M-5D-1 L-T@A-5D-1 L-T@M-12D-1 L-T@A-12D-1 L-T@M-24D-1 L-T@A-24D-1 L-T@M-5-1 L-T@A-5-1 L-T@M-12-1 L-T@A-12-1 L-T@M-24-1 L-T@A-24-1 -T@M-1 -T@A-1 L-T@M-5D-2 L-T@A-5D-2 L-T@M-12D-2 L-T@A-12D-2 L-T@M-24D-2 L-T@A-24D-2 L-T@M-5-2 L-T@A-5-2 L-T@M-12-2 L-T@A-12-2 L-T@M-24-2 L-T@A-24-2 -T@M-2 -T@A-2 without Voltage Reduction Unit Momentary operation (Self-resetting) Pushbutton color symbol *1 G: green, W: white G: green, W: white *1. Enter the desired color symbol for the Pushbutton in the @. *2. Black ( B ) Pushbuttons are only available for non-lighted models. Oil-resistant IP66 Item Output Lighting without Voltage Reduction Unit Incandescent lamp Operating voltage Incandescent lamp Alternate operation (Self-holding) 5L-T@M-5D-1 5L-T@A-5D-1 5L-T@M-12D-1 5L-T@A-12D-1 5L-T@M-24D-1 5L-T@A-24D-1 5L-T@M-5-1 5L-T@A-5-1 5L-T@M-12-1 5L-T@A-12-1 5L-T@M-24-1 5L-T@A-24-1 without Voltage Reduction Unit Momentary operation (Self-resetting) 5-T@M-1 5-T@A-1 5L-T@M-5D-2 5L-T@A-5D-2 5L-T@M-12D-2 5L-T@A-12D-2 5L-T@M-24D-2 5L-T@A-24D-2 5L-T@M-5-2 5L-T@A-5-2 5L-T@M-12-2 5L-T@A-12-2 5L-T@M-24-2 5L-T@A-24-2 5-T@M-2 5-T@A-2 Pushbutton color symbol *1 G: green, W: white G: green, W: white *1. Enter the desired color symbol for the Pushbutton in the @. *2. Black ( B ) Pushbuttons are only available for non-lighted models. Individual models: Refer to pages 9 to 13. (The Pushbutton, Lamp, Case, and Switch can be ordered Ratings: Refer to page 16. Characteristics: Refer to page 16. Accessories: Refer to page 15. separately.) 5

Ordering Information Ordering as a Set... The model numbers used to order sets of Units are given in the following tables. One set comprises the Pushbutton, Lamp (lighted models only), Case, and Switch. Models with Reduced-voltage Lighting and Solder Terminals @-T1 Note: Models with voltage ratings of 200 to 220 VAC/DC (T2 models) are listed with models with screw-less clamp Item Output Lighting Momentary operation (Self-resetting) Operating voltage 100/110 VAC/VDC L- @M-T1-1 (with built-in reduced-voltage lighting function) 100/110 VAC/VDC L- @M-T1-2 Alternate operation (Self-holding) L- @A-T1-1 L- @A-T1-2 Pushbutton color symbol * * Enter the desired shape for the Pushbutton in : J (rectangular), A (square), or T (round). Enter the desired color symbol for the Pushbutton in the @. Oil-resistant IP66 Item Output Lighting Momentary operation (Self-resetting) Operating voltage 100/110 VAC/VDC 5L- @M-T1-1 (with built-in reduced-voltage lighting function) 100/110 VAC/VDC 5L- @M-T1-2 Alternate operation (Self-holding) 5L- @A-T1-1 5L- @A-T1-2 Pushbutton color symbol * * Enter the desired shape for the Pushbutton in : J (rectangular), A (square), or T (round). Enter the desired color symbol for the Pushbutton in the @. Screw-less Clamp Models @-2S Item Output Lighting Operating voltage Momentary operation (Self-resetting) Alternate operation (Self-holding) L- @M-5D-2S L- @A-5D-2S L- @M-12D-2S L- @A-12D-2S L- @M-24D-2S L- @A-24D-2S (with built-in 100/110 VAC/VDC L- @M-T1-2S reduced-voltage lighting function) 200/220 VAC/VDC L- @M-T2-2S L- @A-T1-2S - @A-2S - @M-2S L- @A-T2-2S Pushbutton color symbol *1 *1. Enter the desired shape for the Pushbutton in : J (rectangular), A (square), or T (round). Enter the desired color symbol for the Pushbutton in the @. *2. Black ( B ) Pushbuttons are only available for non-lighted models. Oil-resistant IP66 Item Output Lighting Operating voltage Momentary operation (Self-resetting) Alternate operation (Self-holding) 5L- @M-5D-2S 5L- @A-5D-2S 5L- @M-12D-2S 5L- @A-12D-2S 5L- @M-24D-2S 5L- @A-24D-2S (with built-in 100/110 VAC/VDC 5L- @M-T1-2S reduced-voltage lighting function) 200/220 VAC/VDC 5L- @M-T2-2S 5L- @A-T1-2S 5- @A-2S 5- @M-2S 5L- @A-T2-2S Pushbutton color symbol *1 *1. Enter the desired shape for the Pushbutton in : J (rectangular), A (square), or T (round). Enter the desired color symbol for the Pushbutton in the @. *2. Black ( B ) Pushbuttons are only available for non-lighted models. 6

Ordering Information Ordering as a Set... The model numbers used to order sets of Units are given in the following tables. One set comprises the Pushbutton, Lamp (lighted models only), Case, and Switch. Models with PCB Terminals @-P Item Output Lighting Operating voltage Momentary operation (Self-resetting) L- @M-5D-1P L- @M-12D-1P L- @M-24D-1P Pushbutton color symbol *1 - @M-1P L- @M-5D-2P L- @M-12D-2P L- @M-24D-2P R: red Y: yellow G: green W: white - @M-2P Note: Contact your OMRON representative about Selector Switches and Key Selector Switches. *1. Enter the desired shape for the Pushbutton in : J (rectangular), A (square), or T (round). Enter the desired color symbol for the Pushbutton in the @. *2. Black ( B ) Pushbuttons are only available for non-lighted models. IP66 Item Output Lighting Operating voltage Momentary operation (Self-resetting) 5L- @M-5D-1P 5L- @M-12D-1P 5L- @M-24D-1P Pushbutton color symbol *1 5- @M-1P 5L- @M-5D-2P 5L- @M-12D-2P 5L- @M-24D-2P R: red Y: yellow G: green W: white 5- @M-2P Note: Contact your OMRON representative about Selector Switches and Key Selector Switches. *1. Enter the desired shape for the Pushbutton in : J (rectangular), A (square), or T (round). Enter the desired color symbol for the Pushbutton in the @. *2. Black ( B ) Pushbuttons are only available for non-lighted models. 7

Ordering Information Illumination Only and Colored Illumination for Models with s With illumination only, the color of the lighted surface is the same when the is lit and when it is not lit. Example: Red Illumination Not lit Cap (red) Red Legend plate Dispersion plate (milky white) Operation Unit Lit Red Reflective plunger lamp (red) Lamp With colored illumination, the color of the lighted surface is white when the is not lit and the emits another color when it is lit. Example: Red Illumination Not lit Cap (translucent) White Legend plate Dispersion plate (milky white) Operation Unit Lit Red Reflection plunger lamp (red) Lamp Ordering: For colored illumination, order the Pushbutton, Case, Lamp, and Switch separately. Color emitted when lit Red Yellow Green Blue Operation Unit L-@W IP66 5L-@W Insert one of the following symbols into the box (@). J: A: Square T: Round Case Momentary: -C@M Alternate: -C@A IP66 Momentary: 5-C@M Alternate: 5-C@A Insert one of the following symbols into the box (@). J: (2-way guard) A: Square (2-way guard) T: Round (projected) Lamp () Switch -@DSR -@DSY -@DSG Specify one of the following symbols in the Refer to page 14. Any box (@). Switch can be mount5: ed. 12: 24: -@DA 8

Ordering Information Ordering Individually... Pushbuttons, Lamps, Cases, and Switches can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Pushbutton Models Square Models Round Models Note: Use Operation Units with Case and use IP66 Operation Units with IP66 Case. There is no Legend Plate built into the Operation Unit. A Legend Plate is built into the Operation Unit. However, if the Operation Unit is black (non-lighted models only), a Legend Plate is not built in. Case Note: Operation Unit Sets that combine an Operation Unit and a Case are also available. (Refer to page 10.) Lighted Models Models Lamp Incandescent lamp Switch Solder terminals (no transformer) Lighted/non-lighted Ordering set combinations: Refer to pages 3 to 7. Note: Switch Units that combine a Lamp and a Switch are also available. (Refer to page 11.) Specifications: Refer to page 16. Accessories, Replacement, and Tools: Refer to page 15. 9

Ordering Information Units... Select a Pushbutton Unit (Pushbutton and Case) and a Switch Unit (Lamp and Switch). Operation Unit, square, round Lighted Models Lighted/ Model Switch Unit with Voltage-reduction Lighting Switch Unit with Screw-less Clamp Connectors Lamp Voltage-reduction lighting Lamp Lighted/ Note: An rated is built-in. Note: models do not include a Lamp. Unit Sets... Sets that combine an Operation Unit and a Case. Operation Unit Appearance Oil-resistant IP66 Classification (2-way guard) Momentary Square (2-way guard) operation Round (projected) (2-way guard) Alternate operation Square (2-way guard) Round (projected) (2-way guard) Momentary Square (2-way guard) operation Round (projected) (2-way guard) Alternate operation Square (2-way guard) Round (projected) Model -J@M -A@M -T@M -J@A -A@A -T@A 5-J@M 5-A@M 5-T@M 5-J@A 5-A@A 5-T@A Insert one of the following symbols into the box (@). Symbol R Y PY A W GY G B Color Red Yellow Pure yellow Blue White* Green Green Black Remarks indicator, incandescent lamp, or non-lighted only Incandescent lamp or non-lighted only * Use this pushbutton color if the illumination color of the is white or pure white. 10

Ordering Information Unit Sets... Sets that combine a Switch and a Lamp. Switch Units with Incandescent Lamps Appearance Classification Standard loads and microloads Model L-@-1 L-@-2 Model L- -@-1 L- -@-2 L- -@-1P L- -@-2P Solder terminals Switch Units with Lamps Appearance Classification Solder terminals Standard loads and microloads PCB terminals Switch Units with Voltage-reduction Lighting (Soldered Terminals) Appearance Classification Operating voltage Model 100/110 VAC/VDC L- -T1-1 100/110 VAC/VDC L- -T1-2 Standard loads and microloads Note: An rated is built-in. Switch Units with Screw-less Clamp Connectors Appearance Classification No voltage-reduction lighting Standard loads and microloads Lighted Voltage-reduc- 100/110 VAC/VDC tion lighting Note. 200/220 VAC/VDC Model -2S L- -@-2S L- -T1-2S L- -T2-2S Note: The 100-V models and 200-V models an rated is built-in. Insert symbols in and @. @ Symbol R Y G W A Color Red Yellow Green White Blue Symbol 5 12 24 5D 12D 24D Type Incandescent Operating voltage Note: If the Pushbutton is pure yellow (PY), use white (W) for the Switch Unit. 11

Ordering Information Ordering Individually... Pushbuttons, Lamps, Cases, and Switches can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Pushbuttons Degree of protection Oil-resistant IP66 Square Round Square Round Color Red L-JR L-AR L-TR 5L-JR 5L-AR Yellow L-JY L-AY L-TY 5L-JY 5L-AY 5L-TR 5L-TY Pure yellow L-JPY L-APY L-TPY 5L-JPY 5L-APY 5L-TPY Green L-JGY L-AGY L-TGY 5L-JGY 5L-AGY 5L-TGY White* L-JW L-AW L-TW 5L-JW 5L-AW 5L-TW Blue L-JA L-AA L-TA 5L-JA 5L-AA 5L-TA * Use this pushbutton color if the illumination color of the is white or pure white. Incandescent Lamps (With the exception of green, the Units are the same as for s.) Degree of protection Square Oil-resistant IP66 Round Square Round Color Red L-JR L-AR L-TR 5L-JR 5L-AR Yellow L-JY L-AY L-TY 5L-JY 5L-AY 5L-TR 5L-TY Pure yellow L-JPY L-APY L-TPY 5L-JPY 5L-APY 5L-TPY Green L-JG L-AG L-TG 5L-JG 5L-AG 5L-TG White L-JW L-AW L-TW 5L-JW 5L-AW 5L-TW Blue L-JA L-AA L-TA 5L-JA 5L-AA 5L-TA (Same as Units for incandescent lamps.) Degree of protection Square Oil-resistant IP66 Round Square Round Color Red L-JR L-AR L-TR 5L-JR 5L-AR Yellow L-JY L-AY L-TY 5L-JY 5L-AY 5L-TY Pure yellow L-JPY L-APY L-TPY 5L-JPY 5L-APY 5L-TPY Green L-JG L-AG L-TG 5L-JG 5L-AG 5L-TG White L-JW L-AW L-TW 5L-JW 5L-AW 5L-TW Blue L-JA L-AA L-TA 5L-JA 5L-AA 5L-TA Black L-JB L-AB L-TB 5L-JB 5L-AB 5L-TB Ordering set combinations: Refer to pages 3 to 7. 5L-TR Specifications: Refer to page 16. Accessories, Replacement, and Tools: Refer to page 15. 12

Ordering Information Ordering Individually... Pushbuttons, Lamps, Cases, and Switches can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Lamps Operating voltage High brightness Light color Red -5DSR -12DSR -24DSR Yellow -5DSY -12DSY -24DSY Green -5DSG -12DSG -24DSG White * -5DSW -12DSW -24DSW Blue -5DA -12DA -24DA Pure white -5DPW -12DPW -24DPW Note: 1. If an lamp with normal brightness is needed, select a Lamp used in the A3C. 2. For voltage-reduction lighting use the -24D@. Only lamps can be used. * Use the white together with white or pure yellow Pushbuttons. Incandescent Lamp Appearance Operating voltage Model -5-12 -24 Cases Appearance Oil-resistant IP66 Ordering set combinations: Refer to pages 3 to 7. Classification (2-way guard) Momentary operation Square (2-way guard) Round (projected) (2-way guard) Alternate operation Square (2-way guard) Round (projected) (2-way guard) Momentary operation Square (2-way guard) Round (projected) (2-way guard) Alternate operation Square (2-way guard) Round (projected) Model -CJM -CAM -CTM -CJA -CAA -CTA 5-CJM 5-CAM 5-CTM 5-CJA 5-CAA 5-CTA Specifications: Refer to page 16. Accessories, Replacement, and Tools: Refer to page 15. 13

Ordering Information Switches Appearance Solder terminal Classification Model -1-2 -1P -2P -2S PCB terminal Lighted/non-lighted (common use) Standard load/microload (common use) Screw-less Clamp Switches with Reduced-voltage Lighting Appearance Solder terminal Classification Model -T1-1 -T1-2 100 V Standard load/microload (common use) Screw-less Clamp 100 V -T1-2S 200 V -T2-2S Note: For a Switch with Reduced-voltage Lighting, use the -24D@. 14

Ordering Information Accessories, Replacements, and Tools Accessories Name Appearance Switch Guards Dust Covers Panel Plugs Classification Model For rectangular models ZJ-5050 For square and round models ZA-5050 For rectangular models ZJ-5060 For square models ZA-5060 For round models ZT-5060 For rectangular models ZJ-3003 For square models ZA-3003 For round models ZT-3003 Remarks Cannot be used with the Dust Cover. Cannot be used with the Switch Guard. Can be operated with the Dust Cover attached. Used for covering the panel cutouts for future panel expansion. Protective structure: Color: Black Replacements Name Appearance Legend Plates Color Caps (for ) Classification Rectangu- Oil-resistant lar IP66 Oil-resistant Square IP66 Oil-resistant Round IP66 lamp/incandescent lamp/nonlighted Square lamp Incandescent lamp/non-lighted Round lamp/incandescent lamp/nonlighted Color Caps (for oil-resistant IP66) lamp Incandescent lamp/non-lighted Model Milky ZJ-5204 Milky ZA-5204 Milky ZT-5204 White Red Yellow Pure yellow Blue Green Green Black White Red Yellow Pure yellow Blue Green Green Black Remarks A Legend Plate is provided as a standard feature with the Operation Unit. However, if the Operation Unit is black (non-lighted models only), a Legend Plate is not provided. Z@-5001W Z@-5001R Z@-5001Y Z@-5001PY Z@-5001A Z@-5001GY Z@-5001G Z@-5011B Z@-5101W Z@-5101R Z@-5101Y Z@-5101PY Z@-5101A Z@-5101GY Z@-5101G Z@-5111B Insert one of the following letters into the box (@). J: A: Square T: Round The Color Cap is usually supplied. Replace the Cap if the color is to be changed. When using an indicator, be sure to use a Color Cap that matches the luminescent color of the. The materials used for the and oil-resistant IP66 are different so be sure to use a Color Cap that matches the specifications of the Switch. Tools Name Appearance Model Pushbutton Switch Applicable types Knob-type Key-type EmergenSelector Selector cy Stop Switch Switch Switch Indicator Remarks Operation Unit Extractor A3PJ-5080 Convenient for extracting Pushbutton Switches Screw Fitting Z-3004 Convenient for ganged installation. Socket Unit Lamp Extractor Z-5080 Convenient for extracting the Switch and Lamps. 15

Specifications Approved Standard Ratings UL, cul (File No. E41515) TÜV (EN60947-5-1) (Low Voltage Directive) CCC (GB14048.5) 5 A at 125 VAC, 3 A at 250 VAC (general use) 3 A at 30 VDC (resistive) 3 A at 250 VAC 3 A at 30 VDC 5 A at 125 VAC 3 A at 250 VAC 3 A at 30 VDC Note: Certification has been obtained for the Switch. For detailed information on individual products that have received certification, consult your supplier. Ratings Super-bright Switch Ratings Rated voltage Resistive load 125 VAC 5A 250 VAC 3A 30 VDC 3A Rated voltage Contact Form Internal limiting resistor ±5% Red, yellow, white: 300 Ω Green, blue, pure white: 160 Ω 8 ma ±5% Red, yellow, white: 1 kω Green, blue, pure white: 910 Ω ±5% 2.4 kω Incandescent Lamp Rated voltage Rated current 6 VAC/VDC 60 ma Operating voltage 14 VAC/VDC 40 ma 28 VAC/VDC 24 ma Voltage-reduction Unit ( Lamp) Contact Operating voltage Minimum applicable load: 1 ma at Rated values are obtained from tests conducted under the following conditions. 1. Load: Resistive load 2. Mounting conditions: No vibration and no shock 3. Temperature: 20 ±2 C 4. Operating frequency: 20 operations/min Name Rated current NC Rated voltage Operating voltage NO 110 VAC/VDC 100/110 VAC/VDC (90 to 121 V) 220 VAC/VDC 200/220 VAC/VDC (0 to 242 V) COM Applicable lamp -24DS@ Lamp Characteristics Screw-less Clamp Socket Unit Item Allowable operating frequency Type Mechanical Electrical Pushbutton Switch Momentary operation: 120 operations/minute max. Alternate operation: 60 operations/minute max. *1 100 MΩ min. (at 500V DC) Contact resistance 100 mω max. (initial value) Between terminals of same polarity 1,000 VAC, 50/60 Hz for 1 minute Between terminals of different polarity 2,000 VAC, 50/60 Hz for 1 minute Between each terminal and ground 2,000 VAC, 50/60 Hz for 1 minute Between lamp terminals 1,000 VAC, 50/60 Hz for 1 minute *2 Vibration resistance Malfunction Destruction Shock resistance Malfunction Durability Mechanical Electrical Screw-Less Clamp Recommended wire size 20 operations/minute max. *1 Insulation resistance Dielectric strength Item Usable wires and tensile strength Twisted wire 0.3 mm2 0.5 mm2 0.75 mm2 1.25 mm2 Solid wire 0.5 mm dia. 0.8 mm dia. 1.0 mm dia. 10 N 20 N 30 N 40 N Tensile strength Length of exposed wire Compliant standards 10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms) 2 500 m/s max. 150 m/s2 max. (malfunction within 1 ms) Momentary operation: 2,000,000 operations min. Alternate operation: 200,000 operations min. *1 100,000 operations min. *1 Electric shock protection class Class II PTI (tracking characteristic) 175 Degree of contamination 3 (IEC947-5-1) Weight Approx. 10 g (in the case of a lighted switch with solder terminals) Degree of protection :, Oil-resistant IP66: 5 *3 0.5 mm2 twisted wire or 0.8 mm-dia. solid wire 10 ±1mm JIS C 2811 Terminal Blocks for Industrial Use Operating Characteristics Type Characteristics Operating force (OF) max. Releasing force (RF) min. Total travel (TT) Pretravel (PT) max. Lock travel alternate (LTA) min. * * Alternate operation models only. Pushbutton Switch Oil-resistant IP66 4.41 N 4.91 N 0.29 N Approx. 3 mm 2.5 mm 0.5 mm Ambient operating temperature 10 C to 55 C (with no icing or condensation) Ambient operating humidity 35% to 85%RH Ambient storage temperature 25 C to 65 C (with no icing or condensation) *1. Set and reset constitute one operation. *2. With and incandescent lamp not mounted. *3. Degree of protection from the front of the panel. 16

Nomenclature Model Structure Pushbutton Cap Color of Pushbutton /incandescent models Red, Green, Yellow, White, Blue Neon models Red, Green, White models Red, Green, Yellow, White, Blue, Black Legend plate Dispersion plate Degree of Protection /Oil-resistant IP66 Reflective plunger Flange Shape (@-J) Square (@-A) Lamp Round (@-T) Switch Switch Specifications 5 A at 125 VAC 3 A at 250 VAC 3 A at 30 VDC Minimum applicable load: 1 ma at Terminal Type Solder terminals (tab terminals #110) PCB terminals Screw-less Clamp 17

Dimensions The Dimension shows 2-switch outputs. (Unit: mm) The lamp terminal is also provided with non-lighted models. @-J Solder terminals (tab terminals #110) 28.5 9.5 6 See page 21 for panel cutouts 21.1 10.8 4 Lamp terminal 16 12.2 +0.2 0 dia. 24 min. 19 min. M16 1 Lock ring Mounting nut Lamp terminal 2.8 4.85 12.4 15.8 15.1 21 Packing (t0.5) (for oil-resistant IP66 only) 24 Square @-A Solder terminals (tab terminals #110) 28.5 9.5 6 See page 21 for panel cutouts 21.1 10.8 4 Lamp terminals 16 12.2 M16 1 Lock ring Mounting nut +0.2 0 dia. 19 min. 19 min. Lamp terminals 2.8 4.85 12.4 15.8 15.1 15.1 Packing (t0.5) (for oil-resistant IP66 only) Round @-T Solder terminals (tab terminals #110) 28.5 9.5 6 See page 21 for panel cutouts 21.1 10.8 4 Lamp terminals 16 12.2 dia. 15.1 dia. M16 1 dia. 19 min. 19 min. Lock ring Mounting nut +0.2 0 Lamp terminals 2.8 4.85 12.4 15.8 Packing (t0.5) (for oil-resistant IP66 only)

Dimensions The Dimension shows 2-switch outputs. The lamp terminal is also provided with non-lighted models. @-J@-@P PCB terminals A rectangular model is listed as an example. (Unit: mm) See page 21 for panel cutouts 28.3 26.4 23.1 9.5 6 16 +0.2 0 dia. 21.1 24 min. 10.8 4 9.1 ± 0.05 2.5.4 20.4 6.3 24 min. 14.7 ± 0.05 dia. 0.5 5.1 ± 0.05 M16 1 Lock ring Mounting nut 4.85 12.4.6 15.1 0.5 21 Packing (t0.5) (for oil-resistant IP66 only) 24 @-J@-T1 Voltage-reduction lighting, solder terminals (tab terminals #110) 50.1 42.7 28.5 9.5 6 21.1 10.8 Panel Cutouts 4 0.5 Direction-indication arrow 0.5 16 +0.2 0 dia. 12.2 9.8 24 min. 0.5 Marking face M16 1 Lock ring 23 min. Mounting nut Switch (22.4) 20.6 15.1 8.8 16.6 2.8 12.4 Packing (t0.5) (for oil-resistant IP66 only) 21 24 @-J@-2S, T1-2S, T2-2S Screw-less Clamp 2.8 2 9.5 6 48.9 Panel Cutouts 10.8 4 16 24 +0.2 0 dia. 25 min. 23.9 M16 1 Switch dismounting lever Lock ring Mounting nut 33 min. (31.7) 27.4 15.1 21 24 Lamps Packing (t0.5) (for oil-resistant IP66 only) Incandescent Lamp -5/-12/-24-5D@/-12D@/-24D@ 12 max. 23.5 4 12 max. 0.5 dia. 0.25 6 dia. 2.8 * 4 Cathode (-) 6 dia. 2.54 Anode (+) * The voltage display surface is the same color as the illumination color. The opposite surface is light gray. (For pure white, the entire surface is light gray.) 19

Dimensions (Unit: mm) Accessories, Tools, and Components Extractor A3PJ-5080 20 5 15 10 50 25 Legend Plates ZJ-520@ ZA-520@.9 12.9 ZT-520@ 12.9 13.4 dia. 12.9 0.6 0.6 Screw Fitting Z-3004 12.9 dia. 0.6 Note: 1. The panel is 0.6 mm thick. 2. The panel is made of the materials listed in the following table. 60 2 Degree of protection Color Milky dia. Polyalylate resin IP66 Transparent Materials Polycarbonate resin IP66 Polyalylate resin Panel Plugs (Black Resin) Select the Plug that fits the panel design and mount from the front of the Panel. Panel cutouts are the same as those for Switches. Protective structure: Color: Black Square ZJ-3003 24 ZT-3003 dia. Lock Ring Round ZA-3003 Rough surface 15.8 ± 0.1 dia. @12 17.9 ± 0.1 Rough surface 2 +0.2 0 0 15-0.1 dia. t=1 17.9 ± 0.1 Socket Unit Lamp Extractor Z-5080 10 2 80 8 12 20 20

Dimensions (Unit: mm) Panel Cutouts Solder Terminals and Screw-less Clamp Connectors @-@J/M16@-@J Square @-A/M16@-A Round @-T/M16@-T (Top View) 16 +0.2 0 dia. PCB Terminals @-J/M16@-J (Top View) 24 min. (25 min.) 16 +0.2 0 (Top View) 16 +0.2 0 dia. dia. Square @-A/M16@-A Round @-T/M16@-T (Top View) 24 min. 19 min. (25 min.) 16 +0.2 0 dia. 19 min. (25 min.) 9.1 ± 0.05 19 min. (33 min.) 19 min. (33 min.) Note: Make sure the thickness of the mounting panel is between 0.5 and 3.2 mm. If, however, a Switch Guard or Dust Cover is used, the thickness of the mounting panel must be between 0.5 and 2 mm. If the panel is to be finished with coating, etc., make sure that the panel meets the specified dimensions after coating. Figures in parentheses are for Screw-less Clamp Connectors. 19 min. (33 min.) 24 min. 14.7 ± 0.05 dia. 5.1 ± 0.05 Note: Ensure that the variation in the distance between the centers of neighboring mounting holes is less than ±0.1 mm. Make sure the thickness of the mounting panel is between 0.5 and 3.2 mm. If, however, a Switch Guard or Dust Cover is used, the thickness of the mounting panel must be between 0.5 and 2 mm. If the panel is to be finished with coating, etc., make sure that the panel meets the specified dimensions after coating. Terminal Arrangement Models without Reduced-voltage Lighting ( Pushbutton Switches are also provided with lamp terminals.) Solder Terminals Lighted Switches Lighted Switches Terminal Arrangement (Bottom View) Dimensions of Terminal Holes 2.6 0.9 1.5 2.8 NC Dimensions of Terminal Holes 2.6 0.9 COM 12.2 NC L- NO 7.4 Lamp terminal Terminal Arrangement (Bottom View) 7.4 SW1 Note: The L+ is not shown on the Switch. 1.5 2.8 12.2 Lamp terminal L- NC NO NO COM COM SW1 SW2 Note: The L+ is not shown on the Switch. 21

Dimensions (Unit: mm) PCB Terminals (Lamp terminals are also present on non-lighted models.) Lighted Switches Lighted Switches Terminal Arrangement (Bottom View) Terminal Arrangement (Bottom View) Model, rating, and lot number indication 5.3 NC 3.5 5.3 L- NC COM SW 1 0.8 0.8 4.85 2.7 NO COM COM SW 1 SW 2 12.4 12.4 PCB Cutouts (Bottom View) NO 4.85 2.7 Lamp terminal (t=0.5).6 Lamp terminal (t=0.5) NC L- 3.5 1.5 NO 1.5 Side with TOP indicated Dimensions of PCB Terminals Side with TOP indicated Dimensions of PCB Terminals Side with TOP indicated PCB Cutouts (Bottom View) A ± 0.1.6 Side with TOP indicated 12.4 ± 0.05 12.4 ± 0.05 20 ± 0.1 4.85 ± 0.05 20 ± 0.1 4.85 ± 0.05 L ± 0.1 Five, 1 dia. 6.3 ± 0.05 A = 24 min.: A = 21 min.: Square or round L = 24 min. Use a PCB with a thickness of 1.6 mm. 6.3 ± 0.05 A ± 0.1 L ± 0.1 6.3 ± 0.05 Two, 5 dia. Two, 5 dia. A = 24 min.: A = 21 min.: Square or round L = 24 min. Use a PCB with a thickness of 1.6 mm. Note: Secure the panel to the board using stud bolts if force will be applied to the board after wiring. Note: Secure the panel to the board using stud bolts if force will be applied to the board after wiring. Eight, 1 d Terminal Arrangement Voltage-reduction Lighting (Lamp terminals are also present on non-lighted models.) Solder Terminals Screw-Less Clamps lighted models lighted models Black (Release button) (Bottom view) Side indicating TOP Side with direction arrow Red (Release button) Red (Release button) White (Release button) White (Release button) Black (Release button) Black (Release button) NC2 NC L NO NC NO L C SW1 Black (Release button) Black (Release button) C SW2 12-3.1 dia. (Insertion hole) NC1 - NO2 NO1 C2 + C2 + SW1 C1 C1 SW2 Red (Release button) The voltage-reduction circuit is built in. Voltage-reduction lighting models with Screw-Less Clamps (L-@T1-2S, L-@T2-2S) incorporate voltage-reduction circuits. 22

Dimensions (Unit: mm) Accessory Dimensions Mounted Dimensions with Switch Guard Installed Square ZA-5050 ZJ-5050 24 Torsion spring.1 Torsion spring.1 23.5 23.5 10.5 10.5 Holder (black) Guard (transparent) Panel Cutout (Top View) 24.5 min. Holder (black) Guard (transparent) Panel Cutout (Top View) 19 min. 16 +0.2 0 dia. 16 +0.2 0 dia. 19.6 27 13 13 X X 28 min. Note: This example is for when X is 4.5 mm. If X is not required, the Switches can be mounted with a minimum vertical installation pitch of 24 mm min. 19.6 27 Note: This example is for when X is 4.5 mm. If X is not required, the Switches can be mounted with a minimum vertical installation pitch of 24 mm min. If PCB terminals are used, provide X must be 24 mm or larger. 28 min. Dust Covers ZJ-5060 Cover B (transparent) Cover A (black) Panel Cutouts 16 +0.2 0 dia. 31 min. 24 25 min. 30 19.6 13.8 Square ZA-5060 27 Cover B (transparent) Cover A (black) Panel Cutouts 25 min. 16 +0.2 0 +0.2 0 dia. dia. 24 25 min. 24 13.8 Round ZT-5060 19.6 27 Cover B (transparent) Cover A (black) Panel Cutouts 25 min. 16 25 min. 24 dia. 13.8 19.6 27 23

Safety Precautions Refer to Safety Precautions for All Pushbutton Switches/Indicators. Do not apply a voltage between the incandescent lamp and the terminal that is greater than the rated voltage. If the incandescent lamp is broken, the operating part may pop out. Always turn OFF the power and wait for 10 minutes before replacing the incandescent lamp. If the lamp is replaced immediately after the power is turned OFF, the remaining heat may cause burns. Precautions for Correct Use Mounting Always make sure that the power is turned OFF before mounting, removing, or wiring the Switch, or performing maintenance. Do not tighten the mounting nut more than necessary using tools such as pointed-nose pliers. Doing so will damage the mounting nut. The tightening torque is 0.29 to 0.49 N m. Using the Microload Insert a contact protection circuit, if necessary, to prevent the reduction of life expectancy due to extreme wear on the contacts caused by loads where inrush current occurs when the contact is opened and closed. The allows both a standard load (125 V at 5A, 250 V at 3 A) and a microload. If a standard load is applied, however, the microload area cannot be used. If the microload area is used with a standard load, the contact surface will become rough, and the opening and closing of the contact for a microload may become unreliable. The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% (λ 60) (conforming to JIS C5003). The equation, λ 60 = 0.5 10-6/operations indicates that the estimated malfunction rate is less than 1/2,000,000 operations with a reliability level of 60%. Voltage (V) WARNING Wiring Solder terminals and quick-connect terminals (#110) are commonly used for terminals. Be sure to use electrical wires that are a size appropriate for the applied voltage and carry current (conductor size is 0.5 to 0.75 mm2). Perform soldering according to the conditions provided below. If the soldering is not properly performed, the lead wires will become detached, resulting in short-circuits. 1. Hand soldering: 350 C, within 3 s 2. Dip soldering: 350 C, within 3 s Wait for one minute after soldering before exerting any external force on the solder. Use non-corrosive resin fluid as the flux. Make sure that the electric cord is wired so that it does not touch the Unit. If the electric cord touches the Unit, then electric wires with a heat resistance of 100 C min. must be used. After wiring the Switch, maintain an appropriate clearance and creepage distance. 0.15 ma 30 24 Microload area 12 Invalid area 5 1 10 100 1,000 Current (ma) The current-limiting resistor is built-in, so external resistance is not required. Rated voltage Operating Environment This Switch is intended for indoor use only. Using the Switch outdoors will cause the Switch to fail. If models are used in locations subject to dust, metallic particles, or oil, be careful that none of these penetrates the Switch. The IP66 model is designed with a degree of protection so that it will not sustain damage if it is subjected to water from any direction to the front of the panel. Do not use the Switch submersed in oil or water, or in locations continuously subject to splashes of oil or water. Doing so may result in oil of water entering the Switch. 1 ma 0 0.1 Internal limiting resistor Red, yellow, white: 300 Ω Green, blue, pure white: 160 Ω Red, yellow, white: 1 kω Green, blue, pure white: 910 Ω 2.4 kω Others The oil-resistant IP66 uses NBR rubber and is resistant to general cutting oil and cooling oil. Some particular oils cannot be used with the oil-resistant IP66, however, so contact your OMRON representative for details. The durability of the Switch depends in the switching conditions. Always test the Switch under actual application conditions to confirm applicability and use the Switch only for the number of switching operations that will not affect performance. Continuing to use the Switch with degraded performance will eventually result insulation faults between circuits, burning of the Switch, or other failures. If the panel is to be finished with coating, etc., make sure that the panel meets the specified dimensions after the coating. Do not subject the Switch to extreme shock or vibration. Doing so will cause malfunctions and damage to the Switch. Do not let sharp objects come into contact with the Switches that are made of resin. Doing so will damage the Switches, causing scratches on the outside of the operating parts, and malfunction. When handling the Switches, do not throw or drop them. 24

Rubber is used inside IP66 models. Do not allow the rubber to become scratched or foreign matter to become attached to the rubber. Scratches and foreign matter will degrade the waterproofing, and the Switch may fail operate correctly. Do not allow the Switch to drop and hit the ground. Precautions 1. The mounting panel thickness must be 0.5 to 3.2 mm. 2. The mounting ring must be tightened to a torque 0.29 to 0.49 N m. 3. The procedure for making the mounting hole for the screw-less clamp connector is described on page 21. A mounting dimension of at least 33 mm is required, however, because the Switch is removed with the screw-less clamp connector mounted to the panel. If Switches are mounted side-by-side separated by less than the specified distance, it may not be possible to remove the Switch. 4. Be sure to mount the Case to the Switch with the correct orientation. Mount with the dimple on the Case facing in the same direction as the side of the Switch with the direction arrow or the word TOP. Direction arrow dimple Case Switch TOP mark Do not place or drop heavy objects on the Switch. dimple Case Do not operate the Switch with hard or sharp objects. Hammer Screwdriver Screw-less Clamp Wiring Procedure Connecting Wires Switch 5. Bend the end of the wire if braided wire is used with the screwless clamp connector. 6. When wiring, insert the wire until it comes into contact with something. After wiring is completed, pull on the wires to confirm that they are connected securely. 7. After wiring, ensure that continuous pressure is not applied to the terminals. 8. Refer to internal connection diagrams and confirm the terminal numbers before wiring. 1. Strip the wires for 10 mm (allowable range: 10± 1 mm). 2. If braided wire is used, twist the wire to straighten it out. 3. Insert the wire into the insertion hole while pressing the release button at the side of the hole. (Using a precision screwdriver is recommended.) 4. Let go of the release button to lock the wire into place. 5. After locking, pull on the wire gently to confirm that it is securely locked. Removing Wires 1. Remove wires by pulling them while pressing the release button. Note: When reusing wires that have already been locked one, cut off the end of the wire and strip the wire again before using. 25

Panel Mounting Removing the Switch Unit After mounting the Pushbutton Unit to the panel, snap in the Switch from the back of the panel. Mounting to the Panel Grip the part between the Switch holder of the Case and the Switch Unit using the Z-5080 Extractor, and pull to remove the Switch Unit. Insert the Pushbutton Unit into the front of the panel, and fix the lock ring and mounting nut from the terminal side. Make sure that the lock ring is aligned with the thread of the Case and the edge of the lock ring is touching the panel. Tighten the mounting nuts to a torque of 0.29 to 0.49 N m. Panel Mounting nut Case Thread Z-5080 Extractor Note: Refer to page 21 for PCB terminals. Lock ring Edge Engraving Engraving the Legend Plate The characters must not be engraved deeper than 0.4 mm. Apply an alcohol-based paint coating, such as melamine, phthalate, or acrylic resin paint coating. Mounting the Switch Unit Snap on the Switch Unit to the Pushbutton Unit. Make sure that the Switch Unit has the correct orientation when snapping it onto the Case. Align the dimple on the Case with the groove between the case guards on the NC terminal side of the Switch Unit in the way shown below, and push the Switch Unit into the Case until it clicks into place. Confirm that the Switch Unit is securely in place before using. Mounting and Replacing the Pushbutton Removing and Mounting the Pushbutton (1) Remove the Pushbutton as shown in the following diagram. If the Pushbutton cannot be removed by hand, use the A3PJ-5080 Extractor. Groove between case guards Pushbutton dimple NC terminal (2) When mounting the Operation Unit to the Case, press the entire surface of the Operation Unit to surface A of the Case as shown in the following diagram. Operation Unit Case Surface A 26

Installing the Lamp Removing the Lamp When mounting the Lamp, make sure it is facing the direction shown in the following diagram. Insert the Lamp while matching the protruding part of the Lamp and the small guides on the outer surface of the Case. (1) Removing from the Pushbutton End Lamp Grip the Lamp with the Z-5080 Extractor and pull to remove. Protruding part The Lamp can be mounted from the Pushbutton end by using the Z-5080 Extractor. The lamp can be mounted by following the opposite procedure for removing the Lamp. (2) Removing from the Switch End The Lamp can be removed by hand once the Switch is removed using the Z-5080 Extractor. Mounting the Z Dust Cover Cover B (transparent) Pushbutton Unit Set ZJ-5060 1. 2. 3. 4. Separate the Dust Cover into 2 parts: cover A and cover B. Insert the Case (Pushbutton Unit) into cover A. Mount these parts together onto the panel. From the back of the panel, mount the lock ring and secure with the mounting nut. 5. Insert cover B into cover A. Ensure that the entire perimeter of cover B is securely attached to cover A by pressing in different directions. 6. Mount the Switch to the Case. Note: Recommended panel thickness: 0.5 to 2 mm. Cover A (black) Panel Lock ring Mounting nut Switch Mounting the Z Switch Guard Switch Guard Panel Pushbutton Unit 1. Insert the Case (Pushbutton Unit) into the Switch Guard. 2. Mount these parts together onto the panel. 3. From the back of the panel, mount the lock ring and secure with the mounting nut. 4. Mount the Switch to the Case. Note: Recommended panel thickness: 0.5 to 2 mm. Lock ring Mounting nut Switch 27

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTAL FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2015.9 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)copyright OMRON Corporation 2015 All Right Reserved.