PV-80 Remotely Operated Cryogenic Flow Control Globe Valve Installation, Operation, and Maintenance Manual

Similar documents
MANUAL OPERATED CRYOGENIC GLOBE VALVE

PV-70 Remotely Operated Cryogenic Globe Valve Installation, Operation, and Maintenance Manual

2001 SERIES CRYOGENIC BAR STOCK BODY VALVES

EC4 SERIES CRYOGENIC VALVES 1/4 2 Sizes

Baumann Mikroseal Control Valve

Baumann Sanitary Diaphragm Angle and Inline Control Valve

PHPK Technologies SPECIFICATION

PHPK. Cryogenic Valves TECHNOLOGIES INCORPORATED

Baumann Sanitary Diaphragm Angle & In-Line Control Valve Instructions

DL/DS Series Diaphragm Valve

RACK & PINION ACTUATORS 2R40 to 2R1750 Series Installation & Maintenance Manual

CONTROL VALVES. Installation, Maintenance & Operating Instructions. Read these instructions carefully before installation or servicing.

Model DFR 070/156/220 Rotary Actuator

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

Baumann Series Flexsleev Control Valve Instructions

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB-SR-S SEISMIC SPRING RETURN SERIES PNEUMATIC ACTUATORS

Fisher 2052 Diaphragm Rotary Actuator

Series 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve

Baumann Little Scotty Bronze Control Valve

DA Series Diaphragm Valve

Series 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve

Installation Operation and Maintenance Instructions Model Contents

Baumann Sanitary Angle Control Valve

Baumann 24000F Wafer Control Valve

Baumann Way Control Valve

THD-SERIES S11DA280 THRU S27DA1020 & S11SR280 THRU S27SR1020 DOUBLE ACTING & SPRING RETURN SCOTCH YOKE ACTUATORS

J Flow Controls Model Numbering

BETTIS ACTUATOR & CONTROLS SERVICE INSTRUCTIONS FIELD CONVERSION OF SPRING CARTRIDGE FAIL DIRECTION CLOCKWISE TO COUNTER-CLOCKWISE OR THE INVERSE

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

Fisher RSS Lined Globe Valve

Gate Valve Maintenance & Adjustment Procedures

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER PROBE REGULATOR

GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS

GATE VALVE MAINTENANCE AND ADJUSTMENT PROCEDURES

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Hydraulic Motors Repair Instructions

Disassembly and Reassembly for CBB-SR (Spring Return) Series Pneumatic Actuators

TECHNICAL INSTRUCTIONS Heavy Duty Bronze Series

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves

Fisher 1051 and 1052 Style H and J Sizes 40, 60 and 70 Rotary Actuators

Model DF233 Control Valve

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

Model DF269 Control Valve

Hard Seat Fluid Pressure Regulator

Powers Controls 656 Powermite Valve with 3-inch Top Rebuilding

ANDERSON GREENWOOD SERIES 9290 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Service Manual. Balanced Piston First Stage

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Fisher RSS Lined Globe Valve

Fluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL

Design CP Control Valve with ENVIRO-SEAL Bellows Seal Bonnet

Disassembly and Reassembly for CBB (Double Acting) Series Pneumatic Actuators

CV Control Valves Installation and Operation Manual

Series 2200/2220 Control Valve. Operation and Maintenance SCOPE OF MANUAL MAINTENANCE DESCRIPTION VALVE INSTALLATION

BR 01b Control valve

The Solution For The Valve Problems Plug Valves

Shafer SH Series Actuator. Service Manual SHSM Rev. 1 September 2016

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

SERVICE INSTRUCTIONS ASSEMBLY & DISASSEMBLY T50X DOUBLE ACTING HYDRAULIC SERIES ACTUATORS

Tri-Clover Manual and Air Actuated Fractional Valves

KHR Series Regulators

For additional information, please visit our website at SENSOR SPECIFICATIONS

METERING VALVE 2" STEM GUIDED

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR MODEL HD732-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

NEECO INDUSTRIES INC. INSTRUCTION MANUAL 7 1/16 10K SLAB GATE BODY

EP-2 Si Three-Piston Pump

Valtek Auxiliary Handwheels and Limit Stops

Fisher 1052 Size 70 Diaphragm Rotary Actuator

TECHNICAL INSTRUCTIONS #11 REGULATOR Single Seat - Bronze Trim - Composition Disc

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

Maintenance Information

Sachs 48mm Closed Cartridge fork Service Manual

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline EC & EK Series Characterized Control Valves Sizes 1/2 6

Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites

Mounting and operating instructions EB 8093 EN. Series 240 Pneumatic Control Valve for Cryogenic Temperatures. Type and

Model DFR 026 Rotary Actuator

Prospenser. User Manual Mode d emploi Bedienungsanleitung Manual Usuario. For capacities of 2.5 ml 5 ml 10 ml 30 ml and 50 ml

Sempell High Pressure Stop Valves Model VA500 (ASME)

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM

Model DFRP Rotary Actuator

SY-SERIES S04DA75 THRU S06DA180 & S04SR75 THRU S06SR180 DOUBLE ACTING & SPRING RETURN SCOTCH YOKE ACTUATORS

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

Before installation these instructions must be fully read and understood

MP and MP Diaphragm and Seal Kits for MP8000 Series Actuators

AIRGO MISTING SYSTEM MAINTENANCE

490 Series Actuators. 490 Series. Contents. Introduction

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

TABLE OF CONTENTS. 3 Outlet Stainless Steel Body. 3 Outlet Ductile Body. 2 Outlet Ductile Body 2 Outlet Bronze Body

Circulation Kits for CP Pumps

Fisher D4 Control Valve Assembly

Integra Pneumatically Operated Distribution Valves

EP-2 Three-Piston Pump

Table Of Contents. Section Description Page #

INSTRUCTION AND MAINTENANCE MANUAL GFH45 PRESSURE REGULATOR

Series 9000 Control Valves RESEARCH Control Valves

Temperature Sensor Series

Installation, Operation and Maintenance Manual for Pressure/Vacuum Relief Valves

Tri-Clover Manual and Air Actuated Fractional Valves

Transcription:

Control lobe Valve Installation, PV-80 Remotely Operated Cryogenic Flow Control lobe Valve Installation, Page of 0

Control lobe Valve Installation, TABLE OF CONTENTS. INSTALLATION... 2 2. OPERATION... 4 3. MAINTENANCE... 4 4. PRESSURE RATINS... 6 5. CONTACT INFORMATION... 6 6. REPLACEMENT PARTS... 7. INSTALLATION The valve must be disassembled prior to installation to prevent damage to soft goods during welding. Item numbers are shown in the parts diagrams, Figure and Figure 2... Valve Disassembly The valve has been factory calibrated and set to ensure proper fail safe operation. Before proceeding, mark one of the wrench flats at the top of the Valve Stem (5) with a marker so it can be returned to the factory settings. On fail-closed operators, apply air pressure to the positioner and set the valve to approximately 50% open. Loosen the Operator Shaft Jam Nut (52). Turn the Stem to remove it from the Operator (5) shaft. o Count and document the number of revolutions made by the marked wrench flat. Loosen the Operator Yoke from the Bonnet as follows: o For ½ to 4" NPS valves, remove the Operator Yoke Jam Nut (54) by turning it counterclockwise. o For 6" and 8" NPS valves, remove the Operator Yoke Bolts (55). Lift the Operator off of the Bonnet (0) and carefully set it aside. o For ½ to 4 NPS valves, also remove the Operator Yoke Adapter (58) and set it aside. Remove the Bonnet Bolts (). Pull Bonnet vertically upward until the top of the Barrel (2) is exposed. Carefully grasp the Barrel so that it will not drop back into the Valve Body, which can damage the PCTFE Seal Disc (36). Page 2 of 0

Control lobe Valve Installation, Remove the Stem from the slot in the Barrel and set the Bonnet and Stem assembly aside. Remove the Barrel (which has the plug assembly attached; parts 32-39) from Valve Body (). Remove Bonnet Face O-Ring (5) and store in a clean area until ready to reassemble. CAUTION: Assembly may contain equipment plated with nickel. Cleaning with acids or other caustic solutions will remove plating and void warranty..2. Welding Prepare connection on equipment on which valve will be installed. Position Valve Body to equipment and weld in place. CAUTION: All Valve Bodies are 304L Stainless Steel. Therefore, care should be taken not to over-heat Valve Body beyond that required for normal welding. CAUTION: When the valve is to be installed in a vacuum jacketed system, care should be taken in the jacket design to prevent forces on the Bonnet of the Valve caused by differential contraction rates (thermal loads) between the inner process line and the vacuum jacket. Contact PHPK for assistance..3. Valve Reassembly Allow Valve Body to cool after welding. Clean Bonnet Face O-Ring and the O-Ring groove on the Valve Body. Apply a very thin film of Halocarbon 25-5S or Krytox rease to the o-ring and replace in groove. Krytox is a registered trademark of DuPont. Reassemble valve in reverse order of instruction given in Section.. o During reassembly, Bonnet Bolts should be tightened as listed in Table. Table Bonnet Bolt Tightening Torque NPS Valve Bonnet Bolt Wrench Tightening Torque in-lb (ft-lb) ½, ¾, /4-20 3/6 Allen 90 (7.5) -½, 2 3/8-6 5/6 Allen 80 (5) 3, 4 /2"-3 3/8 Allen 360 (30) 6", 8" 3/4"-6 -/4" Crescent 200 (00) Page 3 of 0

Control lobe Valve Installation, 2. OPERATION The Operator and Valve have been pre-adjusted to ensure bubble-tight shut-off of the valve at the seat up to.25 times the customer-supplied design pressure rating. No further adjustments should be required. The valve is designed to operate smoothly under all cryogenic conditions. o All moving and contacting parts have closely-held tolerances for free operation. o The self-aligning, tapered plug contains a replaceable PCTFE Seal Disc for positive shut-off. o The Bonnet O-Ring Seals, Barrel O-Ring, and Seal Disc are the only replaceable wear items. 3. MAINTENANCE With proper care, the Valve Assembly should require very little maintenance; however, as with all cryogenic equipment, thorough inspection of the system should be performed periodically to ensure continued, reliable operation. 3.. O-Ring Replacement 3... land Nut O-Rings land Nut O-Rings (7,8) can be replaced by first removing the Operator per Section. instructions. Remove the land Nut (6) from Stem by turning land Nut counterclockwise and sliding it off the end of the Stem. Remove O-Rings from land Nut, taking care not to damage the O-Ring grooves during removal. Clean O-Ring grooves. Apply a very thin film of Halocarbon 25-5S or Krytox rease to the new O-Rings and install them. Reassemble the Valve in reverse order of this section's instructions. 3..2. Bonnet Face O-Ring The Bonnet Face O-Ring (5) can be replaced by first removing the Bonnet per the instructions given in Section.. Remove O-Ring from Bonnet Face, taking care not to damage the O-Ring groove during removal. Clean O-Ring groove. Apply a very thin film of Halocarbon 25-5S or Krytox rease to the new O-Ring and install it. Page 4 of 0

Control lobe Valve Installation, Reassemble valve per Section.3 instructions. 3..3. Barrel O-Ring The Barrel O-Ring (22) can be replaced by first removing the Barrel (2) and plug assembly per the instructions given in Section.. Note: the barrel may have two O-Ring grooves. If this is the case, only the top groove should have an O- Ring in it. The lower groove (near the plug) should be left empty. Clean O-Ring groove. Install the new O-Ring. o New Barrel O-Ring must be split (cut in one location with a razor) prior to installation. o If the O-Ring ends overlap, a second cut is necessary to make the O-Ring lay flat in the groove. o Do not use grease on the Barrel O-Ring. Reassemble valve per Section.3 instructions. 3.2. Seal Disc Replacement 3.2.. For ½ 4 valves The Seal Disc (36) is replaced by first removing the Barrel (2) and plug assembly per Section. instructions. Removing the Flow Plug Screw (32) from the Flow Plug (39). Remove and replace the Seal Disc. The bevel on the outside diameter of the Seal Disc must be oriented as shown in Figure. CAUTION: Care should be taken not to damage sealing serrations in the Barrel. Install the Flow Plug and Flow Plug Screw. Flow Plug Screw should be tightened as listed in Table 2. Reassemble valve per Section.3 instructions. 3.2.2. For 6 and 8 valves The Seal Disc (36) is replaced by first removing the Barrel (2) and plug assembly per Section. instructions. Removing the Flow Plug Screw (32) and the Flow Plug (39). Remove the Seal Disc Support (37) from the Barrel by removing the Seal Disc Support Screws (38) with a 5/6 Allen wrench. Page 5 of 0

Control lobe Valve Installation, CAUTION: Care should be taken not to damage sealing serrations in the Seal Disc Support. Remove and replace the Seal Disc. The bevel on the outside diameter of the Seal Disc must be oriented as shown in Figure 2. Install the Seal Disc Support and tighten all of the Seal Disc Support Screws hand-tight. Torque all of the screws to 80 in-lbs (5 ft-lbs). Install the Flow Plug and Flow Plug Screw. Flow Plug Screw should be tightened as listed in Table 2. Reassemble valve per Section.3 instructions. Table 2 Flow Plug Screw Tightening Torque NPS Valve Flow Plug Screw Allen Wrench Tightening Torque in-lb (ft-lb) ½, ¾, /4-20 3/6 50 (2.5) -½, 2 3/8-6 5/6 420 (35) 3, 4 5/8 - /2 380 (5) 6", 8" 3/4-6 5/8 200 (00) 4. PRESSURE RATINS PV-60 valves from ½ to 8 NPS are designed for a maximum allowable working pressure (MAWP) of 600 psig for temperatures up to 20 F. Valves are individually tested to the customer-specified required pressure. Not all valves are tested to the MAWP. 5. CONTACT INFORMATION PHPK Technologies 2 Builders Place Columbus, OH 43204 Tel (64) 486-4750 Fax (64) 486-4950 www.phpk.com Page 6 of 0

Control lobe Valve Installation, 6. REPLACEMENT PARTS Figure Parts Diagram, ½" to 4" NPS Page 7 of 0

Control lobe Valve Installation, Table 3 Parts List, ½ to 2 NPS Item Description Qty Part Number (by NPS Valve ) ½ & ¾ -½ 2 Valve Body customer specified customer specified customer specified customer specified 5 Stem 8-4-00 8-4-00 8-45-00 8-45-00 6 land Nut 8-39-00 8-39-00 8-395-00 8-395-00 7 O-Ring, land Nut Inner (Viton ) *2-02-22-02-22-02-23-02-23 8 O-Ring, land Nut Outer (Viton ) *2-02-25-02-25-02-28-02-28 0 Bonnet Housing 8-33-00 8-33-00 8-304-40 8-304-420 Bolt, Bonnet (Niflor 2 Coated) 6 8-54-020 8-54-020 8-545-020 8-545-020 5 O-Ring, Bonnet Face (Viton ) * -02-230 -02-230 -02-250 -02-250 6 Bonnet Insert n/a n/a 8-335-240 8-335-240 7 Retaining Ring, Bonnet Insert n/a n/a -2-002 -2-002 2 Barrel, With O-Ring rooves (Niflor 2 Coated) 8-43-50 8-433-50 8-434-60 8-435-050 22 O-Ring, Barrel (Teflon 4 ) * -05-223 -05-223 -05-23 -05-239 32 Screw, Flow Plug (Niflor 2 Coated) 8-54-030 8-54-030 8-545-030 8-545-030 36 Seal Disc (Neoflon 3 M-400H) * 8-48-030 8-483-030 8-484-020 8-485-030 39 Flow Plug, Linear 8-52-00 8-523-00 8-524-00 8-525-00 Flow Plug, Equal Percentage 8-52-020 8-523-020 8-524-020 8-525-020 5 Operator (Many variations available. Call for assistance.) -- -- -- -- 52 Jam Nut, Operator Shaft FAS-70832 FAS-70832 FAS-70834 FAS-70834 54 Jam Nut, Operator Yoke, size 25 8-53-00 8-53-00 8-534-020 8-534-020 Jam Nut, Operator Yoke, size 50 n/a n/a 8-535-00 8-535-00 58 Adapter, Operator Yoke, size 25 8-53-020 8-53-020 8-534-00 8-534-00 Adapter, Operator Yoke, size 50 n/a n/a 8-535-020 8-535-020 95 Soft oods Spare Parts Kit 8-90-020 8-903-020 8-904-020 8-905-020 96 O-Ring rease (Halocarbon 25-5S or Krytox 5 ) * -06-000 -06-000 -06-000 -06-000 See Table 4 Footnotes. Table 4 Parts List, 3 to 4 NPS Item Description Qty Part Number (by NPS Valve ) 3 4 Valve Body customer specified customer specified 5 Stem 8-46-00 8-46-00 6 land Nut 8-396-00 8-396-00 7 O-Ring, land Nut Inner (Viton ) *2-02-224-02-224 8 O-Ring, land Nut Outer (Viton ) *2-02-230-02-230 0 Bonnet Housing 8-336-00 8-336-020 Bolt, Bonnet (Niflor 2 Coated) 8 8-547-050 8-547-050 2 Lock Washer, Bonnet 2 n/a n/a 3 Flat Washer, Bonnet 2 n/a n/a 5 O-Ring, Bonnet Face (Viton ) * -02-2246 -02-2246 2 Barrel, With O-Ring rooves (Niflor 2 Coated) 8-436-50 8-436-400 22 O-Ring, Barrel (Teflon 4 ) * -05-253 -05-256 32 Screw, Flow Plug (Niflor 2 Coated) 8-546-020 8-546-020 36 Seal Disc (Neoflon 3 M-400H) * 8-486-00 8-486-260 39 Flow Plug, Linear 8-526-00 8-526-260 Flow Plug, Equal Percentage 8-526-020 8-526-270 5 Operator (Many variations available. Call for assistance.) -- -- 52 Jam Nut, Operator Shaft FAS-70837 FAS-70837 54 Jam Nut, Operator Yoke, size 25 Supplied with Supplied with Jam Nut, Operator Yoke, size 50 Operator Operator 95 Soft oods Spare Parts Kit 8-906-00 8-907-00 96 O-Ring rease (Halocarbon 25-5S or Krytox 5 ) * -06-000 -06-000 * Recommended spare item. Viton is a registered trademark of DuPont for a fluoroelastomer. 2 Niflor is a trademark of Atotech USA for a composite coating of PTFE and electroless nickel. 3 Neoflon is a registered trademark of Daikin for PCTFE; Kel-F 8 is a registered trademark of 3M for PCTFE. 4 Teflon is a registered trademark of DuPont for PTFE. 5 Krytox is a registered trademark of DuPont. Page 8 of 0

Control lobe Valve Installation, Figure 2 Parts Diagram, 6" to 8" NPS Page 9 of 0

Control lobe Valve Installation, Table 5 Parts List, 6" to 8" NPS Item Description Qty Part Number (by NPS Valve ) 6 8 Valve Body 8-230-070 8-230-250 5 Stem 8-47-00 8-47-250 6 land Nut 8-397-00 8-397-250 7 O-Ring, land Nut Inner (Viton ) *3-02-228-02-2222 8 O-Ring, land Nut Outer (Viton ) *2-02-2224 0-02-2224 0 Bonnet Housing 8-337-050 8-337-250 Bolt, Bonnet (Niflor 2 Coated) 2 8-547-030 8-547-030 2 Lock Washer, Bonnet 2 0-7000-20 0-7000-20 3 Flat Washer, Bonnet 2 0-6000-7 0-6000-7 5 O-Ring, Bonnet Face (Viton ) * -02-2442 -02-2447 2 Barrel, With O-Ring rooves (Niflor 2 Coated) 8-437-020 8-437-260 22 O-Ring, Barrel (Teflon 4 ) * -05-264 -05-27 32 Screw, Flow Plug (Niflor 2 Coated) 8-547-020 8-547-020 36 Seal Disc (Neoflon 3 M-400H) * 8-487-00 8-487-250 37 Seal Disc Support, Linear (Upper Half of Flow Plug) 8-527-00 8-527-250 Seal Disc Support, Equal % (Upper Half of Flow Plug) 8-527-020 8-527-260 38 Screw, Seal Disc Support (Niflor 2 Coated) 6 8-547-040 -- 8 -- 8-547-040 39 Flow Plug, Linear 8-527-00 8-527-250 Flow Plug, Equal Percentage 8-527-020 8-527-260 5 Operator (Many variations available. Call for assistance.) -- -- 52 Jam Nut, Operator Shaft FAS-7084 FAS-7084 55 Bolt, Operator Yoke (Niflor 2 Coated) 8 8-547-060 8-547-060 56 Lock Washer, Operator Yoke 8 0-7000-56 0-7000-56 57 Flat Washer, Operator Yoke 8 0-6000-4 0-6000-4 95 Soft oods Spare Parts Kit 8-908-00 8-908-50 96 O-Ring rease (Halocarbon 25-5S or Krytox 5 ) * -06-000 -06-000 * Recommended spare item. Viton is a registered trademark of DuPont for a fluoroelastomer. 2 Niflor is a trademark of Atotech USA for a composite coating of PTFE and electroless nickel. 3 Neoflon is a registered trademark of Daikin for PCTFE; Kel-F 8 is a registered trademark of 3M for PCTFE. 4 Teflon is a registered trademark of DuPont for PTFE. 5 Krytox is a registered trademark of DuPont. Page 0 of 0