VAPORIX The Automatic Monitoring System for Active Vapour Recovery

Similar documents
VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

TORRIX Magnetostrictive level sensor

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Technical Data Sheet

Solenoid coil for control in potentially explosive areas Type BZ

Centrifugal fan with highly efficient EC drive motor

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

better measurement Simply a question of

ATEX LABELLING FOR MOTORS AND GEAR UNITS

OMNICOMM FUEL-LEVEL SENSORS FUELLING YOUR BUSINESS

Pressure transmitter JUMO dtrans p02

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Differential pressure transmitter PASCAL Ci4 Delta P

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Magnetic Inductive Flow

FasTrak High Capacity Smart Positioner

Product. Information. A.u.K. Müller. Flow meter turbine, with shut-off device. Series Characteristics. Applications.

Magnetic-inductive flow meter for hazardous areas

Technical Datasheet. HM U Series. Turbine Flow Meters. for lubricating liquids

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Safety drying oven with expended temperature range

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

ExBin-P Pressure switches 5 Pa Pa

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Positive displacement batch controller

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features. Display

Gallagher Vapour Recovery

THC Heated FID 3-300A

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Continuous level measuring system NB 4000 Selection list

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Technical Datasheet. HM AC Series. Turbine Flow Meters. for High Pressure Applications up to 1,400 bar

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Electronic Limit Switch Type

Small centrifugal fans made of plastic

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

Flow VA 550 / 570. DVGW tested. Flow.

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Load cell PR for maximum corrosion resistance. Load cell PR 6212 benefits. Mounting kit PR 6012 benefits

CM3-E Operation Manual DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Flash Point Process Analyzer

Compression load cell Inteco, converter Connexx, mounting kits PR 6001, PR 614x

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Safety drying ovens with expanded temperature range

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Technical Datasheet. HM R Series. Turbine Flow Meters. with Female Inch Threads

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Differential pressure gauge Model , copper alloy Model , stainless steel version

LPG STORAGE TANKS & OTHER LPG EQUIPMENT FOR SAFE STORAGE AND DISTRIBUTION OF LPG

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

GEMÜ 205 Electrically operated solenoid valve

Superstatic 440. Static Heat- and Cooling Meter. Application

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

Safety drying ovens. Advantages: Areas of application: FDL series 115

Circulation pumps BFP-ATEX-T3/T4

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

RWE Distribuční služby, s.r.o. ODETTA. Odorizing and dosing system. Natural gas and biogas odorization Methanol and ethanol dosing into natural gas

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Flow meter Type Recordall (RCDL)

HM...TC-R. Turbine Flow Meters for Solvents and Di-Water. Technical Datasheet

Lenze. Drives with worm gearboxes 52.

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

Solenoid Valve Island Type 3965

Compact System NRGS 11-2 NRGS Original Installation Instructions English

SK700-II LPG. Easy LPG solutions adapted to fit your needs

Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1

HAZMAT PUMPS TUP, GUP, IN EX explosion proof up to 620 l/min, up to 2.0 bar

Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive. Series CNH-ML

Temperature sensor TE2

Automatic metal-edge filter AF 75 S / AF 95 S

FPA4 DATASHEET JUNHO 2013

Freefall metal detection system Vistus with separator EC

better measurement Simply a question of

Heat Meter Integrator

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

Type 2REX-A. Oil & Gas / Heavy Industry

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Flap-Type Flow Meter Prall

Rotating Power AC Motors and Generators

SITRANS P measuring instruments for pressure

PHOENIX CONTACT - 01/2008

Freefall metal detection system Vistus with separator ST 2.0

Capacitive level sensors CLS 23

FilterMax F. Modular dust collector with integrated pre-separator. Models

Pressure sensor for liquid and gaseous media QBE620-P...

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

The overfill prevention sensor GWG with tube plug type 907. More than 25 years of FAFNIRexperience. Integrated QSS and ASS function

Transcription:

VAPORIX The Automatic Monitoring System for Active Vapour Recovery SECON VAPORIX-Control VAPORIX-Flow Sensors & Systems Worldwide:

FAFNIR GmbH: Innovation with Tradition. Quality and Satisfaction made in Germany Company The FAFNIR GmbH, based in Hamburg, Germany, develops and manufactures since 1965 filling safety devices, overfill prevention devices, limit signal controllers and continuous level gauging solutions for all types of liquid. The optimisation of process controls, improvements in cost efficiency and the protection of people and the environment are at the heart of our business. Our close and trusting relationship with our customers is a key factor in the practice-oriented implementation of innovative ideas and the functionality of our products. Quality for your satisfaction To provide all customers with devices of consistently high quality, FAFNIR years ago introduced the internationally-recognised, comprehensive quality management system in accordance with ISO 9001 (EN 29001). Our expertise in development and manufacturing of explosion-proof equipment is certified by an independent body. All our products are subject to strict FAFNIR quality requirements. We are committed to meeting international standards and applicable EU directives. 2 FAFNIR Quality and Satisfaction

VAPORIX The Automatic Monitoring System for active Vapour Recovery VAPORIX-Flow, VAPORIX-Control and SECON Product information The VAPORIX automatic monitoring system provides information about the functional state of the active vapour recovery and thus complies with the legal requirements. As an automatic monitoring system for the active vapour recovery VAPORIX serves as protection for people and environment. Application The VAPORIX automatic monitoring system is especially designed for use in petrol stations. Due to its modular structure VAPORIX can be used in all known active vapour recovery systems and fuel dispensers. Features of the FAFNIR technology Fulfils the European requirements of immission control Independent of the type of the vapor recovery system Retrofitting in all common fuel dispensers possible No mechanically moving parts Independent of media Maintenance-free since selfchecking Connection to all suitable cash systems possible Easy start-up and retrofitting ATEX and IECEx approval for Zone 0 TÜV certified VAPORIX Product Information 3

Function The flow sensor VAPORIX-Flow is based on the calorimetric measuring principle. The medium which flows past a heated sensor element absorbs the energy and thus cools it. The volume flow can be concluded from the absorbed heat energy. The incoming media parameters (HC and air) are adjusted by the simultaneous coverage of the HC concentration, i.e. the measured volume flow is captured independently of the media. System design Flow Sensor Measurement evaluation Display VAPORIX-Flow VAPORIX-Control SECON Calorimetric flow sensor Control unit for 2 VAPORIX-Flow Display for cash area Installation instructions VAPORIX-Flow is installed in the vapour recovery pipe before the pump and before any existing control valve and/or condensate separator. VAPORIX-Flow has to be fixed professionally in the dispenser with clamps and in the flow direction in a vertical position. Its 8-wire cable (4 m long, standard) is firmly connected to the sensor and must not be shortened. It has to be guided into the dispenser head through suitable cable glands and to be connected to the control unit mounted inside the head. The control unit VAPORIX-Control has to be mounted outside the Ex-Zone in the head of the fuel dispenser. It contains the supply for two sensors of the type VA- PORIX-Flow. As reference inputs, the corresponding pulse outputs of the dispenser computer have to be connected to the VAPORIX-Control. 4 VAPORIX Function

Technical data Sensor VAPORIX-Flow VAPORIX-Flow Operating data Explosion protection: II 1 G Ex ia IIB T3 Ga Approvals: TÜV 99 ATEX 1509, IECEx TUN 08.0008 Index of protection IP68 Perm. ambient temp.: - 40 C to + 65 C Connections Connection to the VAPORIX-Control Connecting thread: G 3 /8 269 Dimensions Installation length: 269 mm Dimensions in mm VAPORIX-Flow Technical data 5

VAPORIX-Control 117 80 149 Dimensions in mm Technical data Control unit VAPORIX-Control Operating data Explosion protection: II (1) G [Ex ia Ga] IIB Approvals: TÜV 99 ATEX 1508 X IECEx TUN 08.0007 Index of protection IP20 Perm. ambient temp.: - 20 C to + 65 C Power supply: 230 V alternating current, appr. 20 W; Optional: 115 V alternating current Safe max. Voltage: U m = 253 V Connections Power supply: 230 V ~ Pulse inputs: rectangular signal with 5 24 V pulse height, max. 1 khz, duty factor 20 80 % Pulse valency: 100 pulses / litre default setting; Optional: 33 / 50 / 132 / 200 pulses / litre default setting Outputs: 2 x galvanically isolated transistor outputs max. 30 V, 100 ma Interfaces: 1 x RS-232 (service), 1 x RS-485 4-wire (dispenser computer), 1 x RS-485 2-wire (SECON, DOMS, POS) 6 VAPORIX-Control Technical data

VAPORIX Order code Designation Description Order number VAPORIX-Flow 908247 VAPORIX-Control (Basic) (Please specify country code, for example: 0049 for Germany) 908360 VAPORIX-Service Dongle 908249 SECON-Vap Display incl. plug-in power supply 908324 SECON-Vap Display incl. 12 V power supply for DIN rail mounting 908382 VAPORIX Control Order Code 7

Condensate Separator The Condensate Separator for Vapour Recovery Systems Product information The condensate separator is designed for fuel dispensers to be retrofitted with decentralized active vapour recovery systems. The condensate separator collects large quantities of condensate and converts it back into a gaseous state. It is designed for the requirements of vapour recovery systems at petrol stations. Ideal for retrofitting existing equipment Robust construction Maintenance-free The application of the condensate separator increases the lifetime of the pumps and improves the smooth running of the system. A condensate separator should be a part of every vapour recovery system. Features of the FAFNIR technology Easy installation Cost effective Maximum protection of the vapor recovery pumps Technical description Condensate and liquid residues transported by the vapour recovery flow are collected in the condensate separator. They are collected on the bottom. From here they are converted back into a gaseous state by the passing volume flow during the operation. The optimal vapour flow within the condensate separator leads to a quick dissolution of the condensed residue. Improves the smooth running of vapor recovery pumps 8 Condensate separator

Condensate separator G ¼ To membrane vacuumpump MV 320 G ¼ To nozzle NOZZLE 155 Installation instructions The condensate separator is integrated into the vapour recovery system between the nozzle and the vapour recovery pump. In order to guarantee a proper operation the following installation instructions should be observed: The installation position of the condensate separator must always be vertical, i. e. in an upright position (see the drawing). The supply connections must not be interchanged. To fasten the condensate separator standard pipe clamps can be used, if necessary. After installation the system has to be newly calibrated. FAFNIR HAMBURG 908479 Maintenance Instructions If the condensate separator is used according to its intended purpose, it is generally maintenance-free. Ø 50 Dimensions in mm Technical data Connections: G ¼ inner thread Material: completely made of stainless steel 304, wall thickness 1 mm, welded gas-tight Dimensions: H 155 x Ø 50 [mm] Condensate separator Order Code Designation Condensate Separator Order number for Vapour Recovery Systems 908479 Condensate Separator Technical Data 9

VAPORIX-PCM The pulse correction module for vapour recovery systems VAPORIX PCM (Pulse Correction Module) extends and improves the function of pulsecontrolled vapour recovery systems. Product information VAPORIX-PCM is a control module for pulse controlled vapour recovery systems which corrects physically caused drift effects of the vapour recovery rate (e.g. through temperature variations or swelling hoses and seals). Makes a difference between physically based fluctuations and real errors and thus enables the proper repair according to European directives Function With the help of its micro-controlled electronics VAPORIX- PCM reverts to the established history data base inside the VAPORIX-Control. This historybased knowledge enables a highly effective corrective control of the vapour recovery. Features of the FAFNIR technology Suitable for both new installations and retrofit Independent of manufacturerspecific features All influences that could affect the vapour recovery are included. The result is an excellent corrective control that exactly diagnoses failures of the vapour recovery. Easy installation and retrofitting Space saving due to very small dimensions 10 VAPORIX-PMC

Process flow Pulses or pulse packets Fuel flow Side A and Side B VAPORIX- Control Voltage supply The vapor recovery is no longer controlled via the fuel flow pulses, but via corrected pulses VAPORIX- PCM Corrected control pulses Side A Vapor recovery Side A VAPORIX- Flow Corrected flow information Corrected control pulses Side B Vapor recovery Side B Vapour flow Side A and Side B VAPORIX- Flow Technical data VAPORIX-PCM Supply 5 V DC and 30 ma (from VAPORIX control), internal reverse polarity protection up to 30 V DC, screw terminal for max. 1 mm 2. Connecting cable to VAPORIX-Control is included 10 ma DC, max. switching voltage 28 V DC, internal reverse polarity protection up to 30 V DC Screw terminal for max. 1 mm 2 Display of pulse generation by yellow LED Serial port RS485, 4-wire, 10-pin connector, cable for VAPORIX-Control connection is included Operation indication green LED Pulse outputs per side 1 x TTL compatible (4.7 V / 2 ma), short-circuit proof 1 x Optocoupler for generating galvanically isolated pulses via external voltage supply, collector and emitter open, max. switching current VAPORIX PCM Order code Designation VAPORIX-PCM Pulse frequencies 2.0 Hz 200.00 Hz Corresponds to 2.4 l/min (at 50 pulses/l) to 60.0 l / min (at 200 pulses/l) Fault indication red LED Dimensions H 105 x W 24 x D 47 [mm] Housing Module carrier for DIN rail mounting Order number for the corrective control of active vapour recovery 908259 VAPORIX-PMC Technical data 11

FAFNIR GmbH Bahrenfelder Straße 19 22765 Hamburg, Germany Phone: +49/40/39 82 07-0 Fax: +49/40/390 63 39 E-Mail: Internet: info@fafnir.com Sensors & Systems Worldwide: