LV REMOTE CONTROLLER INSTRUCTION MANUAL

Similar documents
LT 9213A LCD FLICKER CHECKER INSTRUCTION MANUAL

Operation Manual. Checking the Package Contents. Electronic Load Booster PLZ2004WB PLZ2004WHB. Accessories (PLZ2004WB) About the Operation Manual

Robot System. Safety and Installation. Robot Controller Control Unit RC700 RC700-A Drive Unit RC700DU RC700DU-A. Programming Software EPSON RC+7.

Impact Torque Meters HIT-Series

Robot System. Safety and Installation. Robot Controller RC90 Programming Software EPSON RC Manipulator LS series (LS3 / LS6 / LS20)

Bar Code Scanner. Quick Start Guide QS Rev A 3/12

Premium Complete Rework Station with Electric Pump

AGQ300-48S1V2 DC/DC Converter. Technical Reference Notes

Declaration of Compliance for Elo AccuTouch Screens

IF THE EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY X-RITE PANTONE, THE PROTECTION PROVIDED BY THE EQUIPMENT MAY BE IMPAIRED

AGQ200-48S1V5 DC/DC Converter. Technical Reference Notes

The Torque Value Checking Meters For Automatic Controlled System HM-10 HM-100

AGQ300-48S1V2 DC/DC Converter. Technical Reference Notes

Model HT640B02. High Temperature 4-20 ma Output Velocity Sensor. Installation and Operating Manual

ValveMate 8040 Controller Operating Manual

HIOS Digital Torque Meters HP-100 HP-10 HP-1 ( ) Option. Operation manual. (May 2018) 18A. No. ET-C006

MAx1-720x Two-Position, MFx Floating, MSx Proportional Series SmartX Actuators Linear Spring Return

AVO100-48S1V5 DC/DC Converter. Technical Reference Note

E30 Series. Installation Guide Power Monitoring. Branch Circuit Power Meter. Product Overview. Product Identification.

ValveMate 8040 Controller

International 9/8/11 WORKING PAPER Edition battery or the exposed to prevent 1.3 (5 页 ) C

Packaging 22Mar11 Rev Y Specification MOD JACK ASSY, VERTICAL, COMPLIANT PIN, 8 POSN

ValveMate 7060RA Controller

ValveMate 8040 Controller

ValveMate 7094DC Auger Valve Controller Operating Manual

更多的机会来源于合作和创新 帝斯曼复合材料树脂集团严政华

781RC MicroMark Recirculating Spray Marking System

794 Series Auger Valve

Cartridge Filling System

List of Attachments (including a total number of pages in each attachment): 附件清单 ( 含每个附件的总页数 ): - Photos documentation (1 page) - 产品图片 (1 页 )

Model ADB FATIGUE RATED LOW PROFILE LOAD CELL, DUAL BRIDGE. Installation and Operating Manual

Technical Information

Force Band USER MANUAL

SAFETY PRECAUTIONS PRECAUTIONS DE SECURITE

在线圈中安装温度限制器 (TB) 和电机热敏电阻保护装置并且必须将两者连接在一起! 注意与维护和服务相关的说明 装配说明书是产品的组成部分, 放到触手可及的地方妥善保存 在运输马达时请采用原包装货将其固定资阿马达壳罩的钻孔上旋入环形螺栓并使用合适的举升工具

3.7V Rated Capacity 2600mAh. Maximum Continuous Charge Current Maximum Discharge. 2600mAh

EEMB CO., LTD. Specification

EJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual. Contents 1. Introduction. 3. Installation. 5.

EEMB CO., LTD. Specification

FPRCL - 90V - 25 M S - 24/2

PARTS ORDERING INSTRUCTIONS

检测 CNAS L0095. Page 1 of 12 Pages. No. :RZUN 检验报告 TEST REPORT 产品名称 : 锂电芯 CLIENT: 委托单位 : 威凯检测技术有限公司 Vkan Certification & Testing Co., Ltd.

Technical Information

Technology for Sale Mirojack Advanced Truck Crane. Mirojack高级汽车起重机技术出售

JINLONG MACHINERY & ELECTRONICS

Brake Dynamometer Test Report

China Automotive Transmission Industry Report,

EEMB CO., LTD. Specification

Ultimus IV Series Dispensing System

NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA 中华人民共和国国家标准. Lubricating oils for turbines 涡轮机油

新能源汽车燃料和材料全生命周期的 能源和环境影响研究 Full Life-cycle Energy and Environmental Impacts of New Energy Vehicles in China

ValveMate 7160RA Radial Valve Controller

Y/11GM Pneumatic Gauge Pressure Transmitter

2600W 4-Channel Intelligent Battery Charger

ValveMate 7194 Auger Valve Controller

TRUCK CRANE 汽车起重机 LT 1130 DATASHEET METRIC 数据表 ( 公制 ) LT Courtesy of Crane.Market

Global and China Automotive Audio and Infotainment System Industry,

FC80 - <offline> "Fault and Alarm monintor"

Product Specification

Product Specification

Cal. Y121E STANDARD 6 3/ mm. 2.99mm. 2 years. Watch Movement Specification and Drawing. Movement Size. Casing Diameter.

Ultimus IV Series. User s Guide. Dispensing System. Ultimus IV-3cc # Ultimus IV-5cc # Ultimus IV-10cc #

产品维修手册. Maintenance Service Manual 中国 厦门蒙发利科技有限公司 蒙发利集团 客服. Xiamen Comfort Science & Technology Co.,Ltd 产品型号 /MODEL: EC-320D

TRUCK CRANE 汽车起重机 LT 1036/1 DATASHEET METRIC 数据表 ( 公制 ) LT 1036/1

Global and China Automotive Lighting Industry Report,

Global and China Automotive Wiring Harness Industry Report,

DJI Snail Racing Propulsion System DJI Snail 竞速多旋翼动力系统

AC Adaptor. Operating Instructions Bedienungsanleitung Manuel d utilisation Instrucciones de Funcionamiento Istruzioni per l uso 使用說明書使用说明书사용설명서

C C S 技术通告. Technical Notice

For Motor Starting Use Schneider Electric Overload Relay Series LR. WARNING

INSTRUCTION MANUAL INFORMATION MANUALS SERVICE ~ 1 ~ Those instructions are for your safety. Read carefully before use, and keep them.

关于执行欧盟 (EC)No. 417/2002 ( EC)No. 782/2003 等法规的有关注意事项

SPX Product Family Smart Melt Pressure Transmitters

南阳防爆集团股份有限公司. Nanyang Explosion Protection Group Co., Ltd.

E-bikes in China: Status, Challenges & Future

产品规格书. 锂聚合物电池 / Lithium Polymer Batteries. PL V-2200mAh 1S1P

RC10 Flashlight. Technical Parameters General Mode ANSI/FSC Turbo Low Mid High. 1h 55min 142h 26h 30min 6h 10min. IPX-8,underwater 2m

Demand & supply study on SS long products in China

SET Thermally protected MOV (Abbreviated TMOV) is a new patent technology in the field of surge protection.

2017 Qualicoat, Qualanod, Qualideco 准及 方法培. Jerry Li 李琰 Chief Representative of Qualisino

T6A OPERATOR S MANUAL FLASHLIGHT

Commercialization of Car-sharing in China

Build your first serverless applica2on on Apache OpenWhisk. Ying Chun Guo (Daisy)

安装手册 INSTALLATION MANUAL

苏世博家居手册 (2018 版 ) 家居气动五金系统专家德国品牌六十五年 引领欧洲家具气撑调节系统解决方案六十五年 中国高端橱柜气撑领导者 中国高端榻榻米生产企业主要供应商 中国儿童桌调节系统市场占有率第一. 扫码关注微信公众号

Deep Research Report on Global and China PV Inverter Industry

PT-0721 Cordless Pocket Screwdriver 7.2V

PHANTOM. Quick Start Manual V1.0

Insert image here. Insert image here. Insert image here. ACS800 and 600 Commision Guide and Thoubleshooting ACS800 /600 调试指导与故障分析

NUBALANCE HOT RUNNER SYSTEM COMPANY PROFILE. Creat advanced value for customer. Hot Runner systems Temperature Controller Robot Mould Base

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC2 4/153. Overview

PACTL Import Transshipment Service 货运站进港中转服务

Replacement of Monitor Unit

Products Series 三一矿机. Product Series. 三一矿机有限公司地址 (Add): 江苏省昆山市经济技术开发区东城大道三一产业园电话 (Tel): 传真 (Fax): SANY MINING

:

SITRANS F flowmeters SITRANS F C. MASSFLO MASS 2100 DI 3 to DI 40 4/143. Overview

Stainless Steel in Exhaust Systems Angel L. Ramirez

Owner s Guide / Guide de l utilisateur / Manual de Uso / 사용자가이드 / 用户指南

Introduction of NS2 Manual Motor Starter

Lithium Battery UN38.3 Test Report

Transcription:

LV 7800-01 REMOTE CONTROLLER INSTRUCTION MANUAL

TABLE OF CONTENTS 1. INTRODUCTION... 1 1.1 Scope of Warranty... 1 1.2 Power Supply Voltage... 1 1.3 Trademarks... 1 2. SPECIFICATIONS... 2 2.1 General... 2 2.2 Features... 2 2.3 Specifications... 2 2.3.1 Control... 2 2.3.2 Panel... 3 2.3.3 Rear Connectors... 3 2.3.4 General Specifications... 3 3. NAMES AND FUNCTIONS OF PARTS... 4 4. PROCEDURE... 5 4.1 Configuring the LV 5800/7800... 5 4.1.1 Checking the Version... 5 4.1.2 IP Address Settings... 6 4.2 Configuring the LV 7800-01... 7 4.2.1 Factory Default Settings... 7 4.2.2 Configuring the LV 7800-01 from a PC... 8 4.2.3 Configuring the LV 7800-01 from the LV 5800/7800... 9 4.3 Control... 10

1. INTRODUCTION 1. INTRODUCTION Thank you for purchasing this LEADER instrument. To use this instrument safely, read this instruction manual thoroughly, and make sure that you know how to use the instrument properly. If some point about the operation of this instrument is still unclear after you have read this instruction manual, refer to the contact information on the back cover of the manual to contact LEADER, or contact your local LEADER agent. After you have finished reading this manual, keep it in a convenient place so that you can refer to it when necessary. 1. 1 Scope of Warranty This LEADER instrument has been manufactured under the strictest quality control guidelines. LEADER shall not be obligated to furnish the following free services during the warranty period. 1. Repair of malfunction or damages resulting from fire, natural calamity, or improper voltage applied by the user. 2. Repair of an instrument that has been improperly repaired, adjusted, or modified by personnel other than a factory-trained LEADER representative. 3. Repair of malfunctions or damages resulting from improper use. 4. Repair of malfunctions caused by devices other than this instrument. 5. Repair of malfunctions or damages without the presentation of a proof of purchase or receipt bill for the instrument. This Warranty is valid only in Japan. 1. 2 Power Supply Voltage Confirm the voltage of the commercial power source before you connect the power plug. The operating voltage range of this instrument is 90 to 250 V. Only use a power source that supplies a voltage within the operating voltage range and has a frequency of 50/60 Hz. 1.3 Trademarks Windows is a registered trademark of Microsoft Corporation in the United States and/or other countries. 1

2. SPECIFICATIONS 2. SPECIFICATIONS 2.1 General The LV 7800-01 can be connected to the Ethernet port on the rear panel of the LV 5800/7800 and used to control the LV 5800/7800 remotely. You can control the LV 5800/7800 remotely using the same panel operations that you would use to control it normally. 2.2 Features Control over the Ethernet The LV 7800-01 makes long-distance remote control over the Ethernet possible. Identical Operations Synchronized to the LV 5800/7800 Panel You can perform the same operations using the LV 7800-1 that you can perform using the LV 5800/7800 panel. You can use the LV7800-01 as if you have the LV 5800/7800 panel right in front of you. Also, the operations that you perform affect the LV 5800/7800 immediately. 2.3 Specifications 2.3.1 Control Supported Models Connection Function Connection Settings Settings LV 5800 (FW Ver. 6.3 and later) LV 7800 (FW Ver. 1.3 and later) Telnet communication over Ethernet (DHCP is not supported.) Controls the LV 5800/7800 by sending control codes. Shows LED indications based on LED data received from the LV 5800/7800. IP Address Subnet Mask Default Gateway Destination IP Address Setting Method Set from a PC application (included with the LV 7800-01) Set from the connected LV 5800/7800 Factory defaults Hold down V POS and H POS while turning on the power. IP Address 192.168.0.2 Subnet Mask 255.255.255.0 Default Gateway 0.0.0.0 Destination IP Address 192.168.0.1 2

2. SPECIFICATIONS 2.3.2 Panel Key LEDs Power LED Ethernet LED All LEDs are lit dimly. The LED of the selected key is lit brightly. (All the LEDs are off when the LV 5800/7800 is off.) Lights when the LV 7800-01 is on. Lights when a connection has been established between the LV 7800-01 and the appropriate LV 5800/7800. 2.3.3 Rear Connectors Ethernet Port Compliant Standard I/O Connector Function Type USB Port Specification Function IEEE802.3 RJ-45 Sends key codes and receives LED data 10Base-T/100Base-TX Type B USB 2.0 Used to set the IP addresses. 2.3.4 General Specifications Environmental Conditions Operating Temperature Operating Humidity Operating Environment Operating Altitude Overvoltage Category Pollution Degree Power Requirements Voltage 90 to 250 VAC Frequency 50/60 Hz 8 W max. Power Consumption Dimensions 0 to 40 C 85 % RH or less (no condensation) Indoors Up to 2,000 m II 2 482 (W) 44 (H) 110 ( D) mm (excluding protruding parts) Weight 1.2 kg Accessories Power cord... 1 Cover/inlet stopper... 1 PC application (CD)... 1 Instruction manual... 1 3

3. NAMES AND FUNCTIONS OF PARTS 3. NAMES AND FUNCTIONS OF PARTS For explanations of each key, see the LV 5800/7800 instruction manual. Figure 3-1 Front panel Fig ure 3-2 Rear panel Table 3-1 Names and functions of parts No. Name Function 1 POWER LED This LED lights when the LV7800-01 is on. 2 ETHERNET LED This LED lights when a connection has been established with the LV 5800/7800. 3 ETHERNET After you use this connector to connect to the LV 5800/7800, you can control it remotely. Also, the LV 5800/7800 key operations affect the LV 7800-01. 4 USB After you use this connector to connect to a PC, you can set the LV7800-01 IP address and other settings from the PC. Use the PC application that comes with the LV 7800-01 (IPAddressWriter) to configure the settings. 5 Serial number The serial number is engraved here. name plate 6 Ground terminal Use this terminal to connect the instrument to an external ground. 7 Power inlet AC power inlet. 4

4. PROCEDURE 4. PROCEDURE 4.1 Configuring the LV 5800/7800 4.1.1 Checking the Version You can only use the LV 7800-01 to control the LV 5800/7800 if the LV 5800/7800 firmware version is as indicated below. Table 4-1 LV 5800/7800 versions Model LV 5800 LV 7800 Firmware Version 6.3 or later 1.3 or later You can check the firmware version in the system information display (see the figure below) or in the startup display. You cannot control a LV 5800/ 7800 whose firmware version is earlier (whose firmware number is lower) than the versions listed above. In such a situation, contact your local LEADER agent. SYS F 5 SYSTEM INFORMATION Figure 4-1 System information display 5

4. PROCEDURE 4.1.2 IP Address Settings To set the LV 5800/7800 IP Address in the ETHERNET display, follow the procedure below. 1. Press SYS F 2 PLATFORM SETUP F 3 NEXT. The ETHERNET display appears. 2. Set Network Select to IP. Figure 4-2 ETHERNET display The LV 7800-01 does not support DHCP. DHCP is enabled in the LV 5800/7800 factory default settings. 3. Specify the IP addresses. The LV 5800/7800 factory default IP address is 192.168.0.1. If you use the factory default settings for the LV 7800-01 and the LV 5800/7800, you do not have to perform the operations in section 4.2, Configuring the LV 7800-01. Use the factory default settings if you want to connect the LV 5800/7800 and the LV 7800-01 in a one-on-one connection. If you want to connect multiple LV 5800/7800s and control them alternately or if you want to set a specific IP address, change the values here. 4. Press F 1 COMPLETE. The settings are confirmed, and the system menu appears. 5. Restart the LV 5800/7800. The Ethernet settings are valid after you restart the LV 5800/7800. You do not need to restart the LV 5800/7800 if you did not change any values in step 2 or 3. 6

4. PROCEDURE 4.2 Configuring the LV 7800-01 Before you connect the LV 7800-01 to the LV 5800/7800, you need to configure the following settings. IP Address Subnet Mask Default Gateway Destination IP Address You can configure these settings from a PC using the PC application that comes with the LV 7800-01, or you can configure them from the LV 5800/7800 if a connection has been established between the LV 7800-01 and the LV 5800/7800. If the LV 5800/7800 IP address is set to 192.168.0.1 and the LV 7800-01 is set to its factory default settings, you do not need to configure the settings in this chapter. Proceed to section 4.3, Control. 4.2.1 Factory Default Settings The LV 7800-01 factory default settings are listed below. Table 4-2 Factory default settings Item Factory Default IP Address 192.168.0.2 Subnet Mask 255.255.255.0 Default Gateway 0.0.0.0 Destination IP Address 192.168.0.1 To return the LV 7800-01 to its factory default settings, turn it on while holding down V POS and H POS. Figure 4-3 V POS and H POS 7

4. PROCEDURE 4.2.2 Configuring the LV 7800-01 from a PC To set the IP addresses of the LV 7800-01 from a PC, follow the procedure below. You will need the following items to set the IP addresses. Table 4-3 Item Necessary Items for Setting the IP Addresses Notes LV 7800-01 PC application Comes with the LV 7800-01 PC USB cable Windows XP or Vista, CD-R drive USB (A) male - USB (B) male 1. Use a USB cable to connect the LV 7800-01 to the USB port of a PC. 2. Turn on the LV 7800-01. The LV 7800-01 does not have a power switch. Connect the power cord. 3. Insert the included CD into the PC, and start IpAddressWriter.exe. The IP Address Writer PC application starts. Destination (LV 5800/7800) IP address LV 7800-01 IP address LV 7800-01 subnet mask LV 7800-01 default gateway Figure 4-4 IP Address Writer 4. Enter the various values, and then click WRITE. You can load the current settings of the LV 7800-01 by clicking READ. 8

4. PROCEDURE 4.2.3 Configuring the LV 7800-01 from the LV 5800/7800 If a connection has been established between the LV 7800-01 and the LV 5800/7800, you can set the IP address of the LV 7800-01 from the LV 5800/7800. However, note that when the IP address settings are changed, the connection between the LV 7800-01 and the LV 5800/7800 is closed. Set the IP address in this manner in situations such as when you want to connect to multiple LV 5800/7800s and switch between them. T o set the IP address of the LV 7800-01 from the LV 5800/7800, follow the procedure below when the ETHERNET LED of the LV 7800-01 is lit. 1. Press SYS F 2 PLATFORM SETUP F 2 PREV. The LV 7800-01 display appears. This display will not appear if a connection has not been established between the LV 7800-01 and the LV 5800/7800. 2. Enter the various values. Figure 4-5 LV7800-01 display The Remote Controller settings are the address settings for the LV 7800-01. The Connection destination settings are the settings for the LV 5800/7800 that you want to connect to. If you select an OFF check box, the settings beneath it are not sent. If you only want to change one set of settings, select the OFF check box above the set of settings that you do not want to send. In the factory default settings, both of the ON check boxes are selected. 3. Press F 1 COMPLETE. The settings are applied when you press F 1 COMPLETE. You cannot change the settings from the LV 5800/7800 again if there is no LV 5800/7800 for the LV 7800-01 to connect to at the newly specified address. If you specify the wrong values, you have to set the LV 7800-01 from a PC. 9

4. PROCEDURE 4.3 Control To use the LV 7800-01 to control the LV 5800/7800 remotely, follow the procedure below. 1. Turn on the LV 7800-01 and the LV 5800/7800. The LV 7800-01 does not have a power switch. Connect the power cord. The POWER LED lights when you turn the LV 7800-01 on. 2. Connect the Ethernet ports of the LV 7800-01 and the LV 5800/7800 using an Ethernet cable. Control You can control the LV 5800/7800 remotely from the LV 7800-01 while the ETHERNET LED is lit. You can also control the LV 5800/7800 directly. When you do so, the LV 5800/7800 key operations affect the LV 7800-01. Notes The LV 7800-01 does not come with an Ethernet cable. The ETHERNET LED lights when a connection is established between the LV 7800-01 and the LV 5800/7800. If the ETHERNET LED does not light, double-check section 4.1, Configuring the LV 5800/7800, and section 4.2, Configuring the LV 7800-01. After the Ethernet cable is removed, the ETHERNET LED remains on for a while. You cannot control multiple LV 5800/7800s from a single LV 7800-01 at the same time. (You can connect multiple LV 7800-01s to the LV 5800/7800 and use them at the same time.) You cannot connect USB memory or headphones to the LV 7800-01. You cannot turn the LV 5800/7800 on and off from the LV 7800-01. When you connect the LV 7800-01 to the LV 5800, the KEY LOCK and SHORT CUT keys are invalid. When you connect the LV 7800-01 to the LV 7800, you cannot adjust the volume from the LV 7800-01. 10

所含有毒有害物质信息 Following information is for Chinese RoHS only 部件号码 : LV 7800-01 此标志适用于在中国销售的电子信息产品, 依据 2006 年 2 月 28 日公布的 电子信息产品污染控制管理办法 以及 SJ/T11364-2006 电子信息产品污染控制标识要求, 表示该产品在使用完结后可再利用 数字表示的是环境保护使用期限, 只要遵守与本产品有关的安全和使用上的注意事项, 从制造日算起在数字所表示的年限内, 产品不会产生环境污染和对人体 财产的影响 产品适当使用后报废的方法请遵从电子信息产品的回收 再利用相关法令 详细请咨询各级政府主管部门 产品中有毒有害物质或元素的名称及含量 部件名称 有毒有害物质或元素 Hazardous Substances in each Part Part s 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr(Ⅵ)) (PBB) (PBDE) 实装基板 主体部开关电源 线材料一套 外筐附件包装材 备注 ) : 表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ/T11363-2006 规定的限量要求以下 : 表示该有毒有害物质或元素至少在该部件的某一均质材料中的含量超出 SJ/T11363-2006 标准规定的限量要求 Ver.1

LEADER ELECTRONICS CORP. 2-6-33 Tsunashima-Higashi, Kohoku-ku, Yokohama 223-8505, Japan PHONE:81-45-541-2123 FAX:81-45-541-2823 http://www.leader.co.jp Jan. 15, 2010 Ver.1