Fire Pump Systems. For the protection of life and property, A-C Fire Pump offers package systems that meet every fire protection need.

Similar documents
Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

Series 4600F. HSC Fire Pumps & Packaged Systems

A-C Fire Pump. Fitting and Accessories A-C 100A

FIRE PUMPS & PACKAGED

Peerless Pump FIRE PUMPS. Horizontal Split-Case, Vertical Turbine, In-Line and End Suction. Sterling Fluid Systems (USA), Inc.

FIRE PUMPS F AI LISTED R LISTED N K S MOR S E P U IT Y S Y S T E M CE R T IF IE D

Waterfall Pumps Manufacturing

PRODUCT OF FIRE PUMPS SYSTEMS

Bristol: A History & Future.

SINCE Double Suction Split Case Fire Pump. Series 4800 & (New Generation) 001-cat f

1100 Series Multi-Stage Vertical Turbine Pumps

PRODUCING TRUST IN FIRE AND SAFETY FIRE PUMP SYSTEMS A PRODUCT OF COMPLIANT.

900 Series Split Case Fire Pump Systems

Centrifugal End Suction Fire Pumps

VSC /VSCS Pumps Technical Brochure

Series HSC-S Pumps Technical Brochure

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

3312 Model. pumping Model Model AURORA Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS

F-Series Fire Fighting Pumps

SERIES WC & WCS. Watchman Series & WCS Condensate Units. Replacement Parts for. Hoffman PARTS LIST DN0436. Hoffman Pump

FIRE PUMP SYSTEMS. FIRE PUMP SINGAPORE PTE LTD No.8 Keng Chin Road #13-11 Cyan South Tower Singapore

Series 1510 Centrifugal Pumps

CURVES B-194. Series e-60 MAINTENANCE FREE IN-LINE MOUNTED CENTRIFUGAL PUMPS PERFORMANCE CURVES

Patent Pending. High Performance Self-Priming. Centrifugal Trash Pumps.

TECHNICAL BROCHURE BAC2000. Series 2000 Closed Coupled. Series 2000 Frame Mounted. Series A-C 2000 SINGLE STAGE END SUCTION

PROJ. NO SECTION HYDRONIC PUMPS

G&L Pumps. TECHNICAL Brochure BAC8100. Series A-C 8100 SPLIT CASE PUMPS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CRP. Chemical Centrifugal Pump Acc. to DIN EN ISO 2858 & DIN EN ISO 5199

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs

4500C Series Vortex Pumps

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

1. Wiring Diagrams: Power, signal, and control wiring.

Goulds Small Capacity Double Suction Pump

High-Head, High Performance, Self-Priming Trash Pumps

Wilo IL Vertical Inline Pumps. Engineering Specification

FE Frame-Mounted End Suction Pumps. Leading The Flow. TACO.

CE Close-Coupled End Suction Pumps. Leading The Flow. TACO.

Fire Pump Capabilities N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

LUBE OIL PUMPS. Critical Lubrication Service for: Bearings Seals Gearboxes. on... Gas & Steam Turbines Compressors Engines Starting Packages

Bulletin C Dean Pump Division. Heavy Duty, High Temperature Process Pumps. R4140 Telescoping Guard. R4140 C-Face Motor Support

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

HIGH VELOCITY PUMP PUMP END

Self-Priming, High Efficiency Pumps

High Temperature Chemical Process Inline Pumps

PWV API 610 Vertical Turbine Pump VS6 (Can Type) VS1 (Sump Type)

PWD. PWD API 610 BB1 Single Stage Pump

Regenerative Turbine Pumps

Flow Range Horsepower Best Eff. Discharge Minimum Rotation➀ GPM Range GPM Connection Well Size 5LS " CCW " CCW

Series Split Coupled Vertical In-Line Pumps. File no.: 43.10in Date: august 14, 2013 Supersedes: 43.10in Date:

INSTRUCTION MANUAL AC2516 REVISION D INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Series 1580 In-Line Mounted Centrifugal Fire Pumps

PWA-LF LOW FLOW ANSI PROCESS PUMP

SUGGESTED SPECIFICATIONS

PWA-IL B73.2 IN-LINE

SECTION HVAC POWER VENTILATORS

High-Head, High-Performance, Self-Priming Trash Pumps

Series CC Condensate Units

320 Series Vertical Sump Pumps

340 Series Double Suction Split Case Pumps

SELF-PRIMING, SOLIDS-HANDLING TRASH PUMPS

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

3800 Series. Single Stage End Suction Pumps. Capacities to 4200 G.P.M. (954 m 3 /hr) Heads to 520 Feet (180 Meters) Temperatures to 300 F (149 C)

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

ZE/ZF Process Pump API 610

Domestic. Pump Series CS Condensate Units SINGLE OR DUPLEX 1,000 THRU 150,000 SQ. FT. EDR-250 THRU 37,500 LB./HR.

Head - m. Flow - US gpm. Comments. Customer : Contact : Re Cotizacion Metro Linea 4 EDB Project : Quote No. :

Vertical Pumps for the Oil & Gas Industry

Instructions for Installation, Operation, Care and Maintenance

Contents. Identification

H 2. O Series CENTRIFUGAL End-suction Pumps. Versatile, really robust and definitely reliable

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

FLHC SERIES DATA BOOKLET

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Goulds API th Edition/ISO nd Edition API OH3 Overhung. Vertical In-Line with Bearing Frame. An ITT Brand

Features 1. Differential Latch-type, lightweight, dependable

DARTMOUTH COLLEGE DESIGN February 15, 2006 & CONSTRUCTION GUIDELINES

TKL. Hydro-Titan Heavy Duty Back Pull-out Water & Process Liquid Pump. Experience In Motion

SCE Heavy Duty, Single Stage, Overhung, API 610 Process Pump (OH2)

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

5LS, 7LS, 10LS, 13LS, 18LS & 25LS 5-25 GPM, ½ 1½ HP, 60 HZ, SUBMERSIBLE PUMPS

FI / SFI Frame-Mounted End Suction Pumps

Pump Division HDX. API 610 Double Suction, Radially Split Process Pump. Bulletin PS-20-4 (E/A4)

Goulds 3181 High-temperature/Pressure Paper Stock/ Process Pumps

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

Pump Division HDX. API 610 Radially Split, Double Suction Process Pump. Bulletin PS-20-4a (E)

PA SERIES END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 THONG FATT JAYA MACHINERY HARDWARE SDN. BHD.

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

SECTION DUST COLLECTOR

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

SECTION AXIAL HVAC FANS

Regenerative Turbine Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPP. Heavy Duty, Single Stage ANSI Chemical Process Pump

Bulletin C Dean Pump Division. ANSI/ASME B73.1 Horizontal Process. ph2140 Telescoping Guard. ph2140 C-Face Adapter

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Goulds 3186 High-temperature/Pressure Paper Stock/ Process Pumps

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

SM / SMI N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

Transcription:

Fire Pump Systems For the protection of life and property, A-C Fire Pump offers package systems that meet every fire protection need. 2C11829

A-C Fire Pump Systems and Professional Fire Protection... A Shared Tradition of Excellence One of the first built fire trucks in the late 1800 s was equipped with an A-C Fire pump. One of the first fire trucks built in the late 1800 s was equipped with an A-C Fire Pump. For over 80 years, A-C Fire Pump Systems has been on the forefront in developing, designing and custom-building a wide range of fire pump systems including prefabricated packages and house units that meet every fire protection need. A-C Fire Pump is not only rich in history, but on the cutting edge of new technology as demonstrated with our contribution to the fire protection systems for launch pads 39A and 39B for NASA at the Kennedy Space Center. A-C Fire Pump Systems furnished a package of four 12x8x22 9100 series horizontal splitcase pumps driven by huge 10 horsepower diesel engines including state-of-the-art control systems. Each pump is rated at 3,00 gallons per minute at 20 psi pressure. We will continue to be the leader in the fire protection industry providing both excellent service and superior products for years to come. You can always count on A-C Fire Pump Systems to solve your pumping problems. To protect the space shuttle launch facilities, NASA installed a fail-safe fire suppression system utilizing A-C Fire pumps. 2

In-Line Pumps Capacity to 100 GPM (,78 L/min) Pressures to 1 PSI (11 m) Working Pressures to 10 PSI n Space saving design n No foundation or pads required. n Suction and discharge flanges are on a common centerline, 180 apart for inline mounting in piping. n Top pullout design allows for fast and easy servicing. The rotating element is easily removed without disturbing suction and discharge piping. n Self-venting design eliminates the need for an automatic air release valve. n Bronze impeller is dynamically balanced and keyed direct to the motor shaft. End Suction Pumps Capacity to 00 GPM (1,892 L/min) Pressures to 10 PSI (10 m) Working Pressures to 20 PSI n Top centerline discharge with foot supported casing. Ease of installation. Simplifies piping layout. Reduces problems associated with piping strain. n Self-venting design eliminates the need for automatic air release valve. n Rear pullout design supplied as standard with spacer coupling. Ease of maintenance, eliminates disturbing driver or piping when removing rotating element. n Hydraulically balanced impeller extends bearing life and assures smoother operation. n Available in electric motor or diesel engine driven configuration. Vertical Turbine Pumps Capacity to 000 GPM (18,92 L/min) Pressures to 30 PSI (247 m) Working Pressures up to 200 PSI with 12 lb. A.S.A. flanges up to 0 PSI with 20 lb. A.S.A. flanges n Required by NFPA when operating under a static suction lift condition. n Dynamically balanced impellers secured to the shaft with steel locking collets to assure proper problem free operation. n Open lineshaft design provides for product lubrication of the bearings. n Available in electric motor or diesel engine driven configuration. n Provided with a bronze suction strainer as standard. n Provided with an oversized air release valve as standard. n Available in special materials of construction for salt water applications.

8100 Series Capacity to 3000 GPM (11,3 L/min) Pressures to 2 PSI (179 m) Working Pressures up to 20 PSI (17 m) with 12 lb. A.S.A. flanges up to 37 PSI (24 m) with 20 lb. A.S.A. flanges n Space saving design. n Available in horizontal or vertical configuration. n Suction and discharge flanges are on a common centerline. n Bearing span is kept to a minimum. n Available in electric motor driven or engine driven configuration. n Available in clockwise or counter-clockwise rotation to simplify pump room layout. 9100 Series Capacity to 000 GPM (18,92 L/min) Pressures to 208 PSI (14 m) Working Pressures up to 17 PSI (123 m) with 12 lb. A.S.A. flanges up to 2 PSI (180 m) with 20 lb. A.S.A. flanges n Space saving design. n Suction and discharge flanges are on a common centerline. n Dual volute casing balances radial forces on the shaft and bearings. n Available in electric motor driven or engine driven configuration. n Available in clockwise or counter-clockwise rotation to simplify pump room layout. 8200 Series Capacity to 1000 GPM (3,78 L/min) Pressures to 40 PSI (40 m) Working Pressures up to 00 PSI (32 m) with 20 lb. A.S.A. flanges up to 800 PSI (3 m) with 800 lb. A.S.A. flanges n Space saving design. n Suction and discharge flanges are on a common centerline. n Bearing span is kept to a minimum. n Compact pump design. n Dual volute casing balances radial forces on the shaft and bearings. n Available in electric motor driven or engine driven configuration. n Two stage pump with two impellers threaded together. n Dynamic balanced impellers. n Available in clockwise or counter-clockwise rotation to simplify pump room layout.

2 1 8 Skid Packages 7 3 4 13 9 10 14 12 11 Select A-C Fire Pumps with confidence... 1 2 3 4 7 8 9 10 11 12 13 14 Pressure sensing lines installed per code requirements UL Listed/FM Approved diesel engine Flowmeter loop Listed OS and Y valve Listed butterfly valve Listed main relief valve Single point electrical connection (all electrical components pre-wired at the factory) Pre-piped fuel system UL Listed FM approved fire pump controller Closed waste cone Listed check valve Stuffing box and engine raw water drain UL Listed fuel tank sized per NFPA #20 UL Listed FM approved fire pump n Components of A-C Fire Pump Systems are labeled by one or more of the following testing laboratories: Underwriters Laboratories (UL), Underwriters Laboratories Canada (ULC), Factory Mutual (FM) n The equipment is completely manufactured at our ISO 9001 facility. n Packaged systems are performance and hydrostatically tested at our manufacturing facility prior to shipment. n Certified welding is available per ASME section IX. n Our fire pump packages have been seismic qualification tested. n Computer and CAD Design capabilities assist you in the design of a system custom built to your specification. Complete drawings are furnished for your approval prior to manufacture. n International distribution and start up capabilities. With A-C Fire Pump Systems you can rest assured of start-up and future product support being available locally, worldwide.

House Packages Big House The largest pre-packaged complete house unit ever built. 4 1 2 3 4 Rigid I-beam base with optional lifting provisions. UL Listed motor for fire protection. Pre-fabricated house designed for specific geographic location. Custom engineered piping system designed for project requirements. Listed control equipment pre-wired to job driver and power distribution panel...one electrical connection. Listed control valves. 1 2 3 This system includes three electric motor driven fire pumps, 1' x 3' and weighs 7,000 lbs.

Versatility a key word at A-C Fire Pump Systems. We realize that each customer has different fire protection needs, specific to each fire hazard. We can design a system around your needs, just like the Saturn automotive plant...special buildings, pump materials and custom floor arrangements. You need it we ll provide it. 7

Package Systems Complete House Units pre-wired and pre-piped instant fire suppression n Engine combustion air intake vent n Battery operated emergency lights n A11V thermostat control ventilating fan n Single point power connection n Exterior photocell sodium vapor light n Pre-piped sprinkler systems for pump house interior n GFCI utility electrical outlets provided n Base is provided with optional lifting provisions n Building heater Vertical Turbine Package NFPA #20 requires the use of a vertical turbine on systems operating under a static suction lift condition requirement. A-C Fire Pump Systems offers the complete pre-packaged system, pump, driver, controller, low measuring device, control valves, check valves, sensing lines and power distribution panel. This system requires one electrical connection and a water supply. It s ready to provide immediate, reliable fire protection. All A-C Fire Pumps are performance and hydrostatically tested in accordance with the requirements of NFPA #20 and are supplied as standard with a packed stuff box, grease lubricated bearings and cast iron/bronze fitted materials of construction. For more information visit our website at www.acfirepump.com Xylem Inc. 8200 N. Austin Avenue Morton Grove, Illinois 003 Phone: (847) 9-3700 Fax: (847) 9-8379 www.acfirepump.com Xylem Inc. Royal Road, Guelph, Ontario N1H 1T1, Canada Phone: (19) 821-1900 Fax: (19) 821-31 A-C Fire Pump is a trademark of Xylem Inc. or one of its subsidiaries. 2013 Xylem, Inc. 2C11829 August 2004