IMP Klima. Swirl diffusers. Variable swirl diffusers

Similar documents
IMP Klima. Swirl diffusers. Variable swirl diffusers

Slot diffusers, Round duct diffusers. IMP Klima

Ceiling swirl diffusers with perforated face plate

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

Ceiling swirl diffusers

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

Ceiling swirl diffusers with perforated face plate

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Ceiling impulse diffuser Model PIL

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

Nozzle Jet Diffuser Model DSA

Ceiling swirl diffusers

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Ceiling swirl diffusers

series 90-GV Variable geometry units

ceiling swirl diffuser DQJ

Ceiling diffuser 4DF

Catalog Swirl diffuser DAL 359

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

ceiling swirl diffuser Model DQJA / DQJR

2/6.1/EN/1. High Induction. Variable / Constant Volume Swirl Diffuser Types HIVV HICV

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

Ceiling Swirl Diffuser DQJ

Ventiduct nozzle ducts

Swirl Diffuser Model DQF

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

1/8/EN/6. Floor Diffusers. Type FB. in aluminium and plastic

INDEX. Chapter1 1. A. Jet diffusers 1. Jet diffuser...: AJD-P

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

DRUM SLOT DIFFUSER TYPE: RT350

Ventiduct nozzle ducts

Ceiling diffuser 4DE

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

C O L M A N. Air Distribution CIRCULAR DIFFUSERS LRS SERIES LRS SERIES

Ceiling Slot Diffuser DSC

SDV Vane Swirl Diffusers

HIGH CAPACITY LINEAR SLOT DUFFUSERS

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

Ceiling Slot Diffuser DSC

Round duct grille Model KG-RR

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

TBV - Terminal Unit. Halton TBV. Terminal Unit

Perforated Face Ceiling Diffusers

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

WGA Long throw nozzle grille

Ceiling induction diffuser DISA-300

Ventilation grilles for installation into walls, sills or rectangular

Ceiling and wall HEPA filter units

ADJUSTABLE PERFORATED AIR SUPPLY DIFFUSER TYPE: DC560S

Ceiling induction diffuser DISA-601

DSC-PLASTER Slot diffuser for plasterboard ceilings

LINEAR SLOT DIFFUSERS

HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY

Floor Swirls Models BZD and SZD

NSDZ. Swirl diffusers with adjustable air control blades

Round duct diffuser DBB-RR

Ceiling Slot Diffuser DSC

Lindab air filtration. Technical Catalogue

Catalog Swirl diffuser DAL 358

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

Ceiling Slot Diffuser Model DSX

Active Chilled Beams

Active Chilled Beams

Ventilation grille Model AL

ADJUSTABLE SLOT DIFFUSER TYPE: SE800

Ventilation grilles for installation into walls, sills or rectangular

N O V E L T Y Diffuser with particulate filter class H13

HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

LINEAR SLOT DIFFUSERS

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

LAQ Return air diffuser

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)


Ventilation grilles for installation into walls, sills or rectangular

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

PUNKAH LOUVRES - PKL DESCRIPTION & FEATURES

series KLR Linear slot diffusers

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

SERIES GP. Security Grilles

DATASHEET PRODUCT CODE EXAMPLE:

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

C O L M A N. Air Distribution FLOOR SWIRL DIFFUSERS B SERIES SERIES

RPD ROUND PLAQUE DIFFUSER

A B. Linear cylinder diffuser LC. pag. A-52

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

Transcription:

Swirl diffusers Variable swirl diffusers

OD-4 OD-11, OD-11V OD-17 OD-7 OD-9 OD-5 OD-14 KD-8 OD-8 OD-

180 242 263 2.7 276 342 368 342

4 4 442 442 560 560 460 460 295x295 295x295 0 395x395 395x395 0 495x495 495x495 0 595x595 595x595 600 6x3 6x6 625 36 22 22 64 42 42 80 68 68 * tolerances according to standard DIN 7168 T1, middle tolerance class (m) ±0.8 mm Air flow Horizontal distance to the wall Room height Distance from ceiling to occupied zone Throw distance (L=H1+x) Air velocity at the throw distance L Temperature difference between supply and room air Temperature difference between air jet and room temperature Pressure drop Sound power level Air velocity at the H1 distance Distance between diffusers by length and by width Isothermal throw lenght, when velocity of supply air jet 0.2 m/s for 4 way discharge H L z A,B V H1 L z x H1 L1.8m V L L

L WA [db (A)] 28 31 36 39 43 p t [Pa] 18 25 34 57 70 L 0.2 [m] 3.8 4.6 4.8 5.0 5.2 L WA [db (A)] 27 34 38 41 44 p t [Pa] 17 24 33 43 54 67 L WA [db (A)] 27 31 37 43 49 p t [Pa] 11 17 26 37 51 66 L 0.2 [m] 3.9 4.7 4.9 5.1 5.3 L WA [db (A)] 26 29 34 37 p t [Pa] 16 25 36 49 64 L WA [db (A)] 26 28 34 39 43 p t [Pa] 9 14 21 28 37 47 L 0.2 [m] 2.8 3.2 3.6 4 4.2 4.6 L WA [db (A)] 26 28 33 38 42 p t [Pa] 22 29 38 49 L WA [db (A)] 28 31 38 41 43 p t [Pa] 11 19 24 43 L 0.2 [m] 2.9 3.3 3.7 4.1 4.3 4.7 L WA [db (A)] 27 29 32 38 41 p t [Pa] 14 19 23 29 42 L WA [db (A)] 26 29 33 37 41 44 p t [Pa] 13 18 25 32 41 L 0.2 [m] 1.8 2.2 2.4 2.8 3.2 3.6 L WA [db (A)] 26 28 32 37 41 44 p t [Pa] 12 17 24 31 39 48 L WA [db (A)] 28 32 36 44 47 p t [Pa] 22 29 39 49 L 0.2 [m] 1.9 2.3 2.5 2.9 3.3 3.7 L WA [db (A)] 29 31 44 47 p t [Pa] 9 21 29 38 47

L WA [db (A)] 29 32 39 41 44 p t [Pa] 13 16 21 26 31 37 L 0.2 [m] 2.6 3 3.6 4.4 5.2 5.8 L WA [db (A)] 29 31 38 41 44 p t [Pa] 13 17 21 27 32 38 L WA [db (A)] 33 37 43 p t [Pa] 13 17 21 26 32 38 L 0.2 [m] 2.8 3.2 3.8 4.7 5.4 6.2 L WA [db (A)] 33 37 43 p t [Pa] 13 17 21 26 32 38 * L WA and p t are given at % open regulation damper φ d H2 φ d h1 H1 top entry spigot side entry spigot measuring damper 290 2 8 143 2 390 285 198 163 280 488 285 198 163 280 590 3 248 188 3 590 3 248 188 3 * tolerances according to standard DIN 7168 T1, middle tolerance class (m) ±0.8 mm

A x A n d h1 φ d H1 H2 side entry spigot top entry spigot measuring damper 280x280 2 0 125 123 390x390 290 2 167 198 390x390 290 2 167 198 590x590 325 2 177 248 590x590 325 2 177 248 * tolerances according to standard DIN 7168 T1, middle tolerance class (m) ±0.8 mm 0KK/Z/S/M % % 0KK/Z/V/M % % 0KR/ZR/S/M % % 0KR/ZR/V/M % % 0 2 0 3 0 4 0 2 0 3 0 4 0 175 0 225 2 275 0 0 175 0 225 2 275 0 2 0KK/Z/S/M % % 0KK/Z/V/M % % 0KR/ZR/S/M 0KR/ZR/V/M 0 3 0 4 0 2 0 3 0 4 0 1800 2 0 3 0 4 1800 2 0 3 0 4 % % % % 600,625KK/Z/S/M % % 600,625KK/Z/V/M % % 600,625KR/ZR/S/M % % 600,625KR/ZR/V/M % % 3 0 4 0 5 600 6 3 0 4 0 5 600 6 0 3 0 4 056006 0 3 0 4 056006

0KK/Z/S/M 0KK/Z/V/M % % % % 125 0 175 0 225 2 125 0 175 0 2252 80 125 0 175 0 80 125 0 175 0 13 7 9 6 5 7 13 8 9 5 4 5 5 13 8 13 9 7 7 7 12 7 8 5 8 7 7 9 8 8 8 5 5 7 7 6 5 4 4 7 11 8 12 7 6 7 12 8 8 8 8 9 9 7 7 7 7 5 7 9 7 5 7 4 4 6 9 8 9 7 5 5 6 9 7 5 5 5 5 6 7 7 6 3 4 6 9 6 8 2 3 4 5 5 8 7 6 4 4 5 9 8 5 3 4 4 6 * Sound attenuation represents insertion losses; this means reduction in the level of sound power due to the inserted unit (swirl diffuser OD-). 0KR/ZR/S/M % % 0KR/ZR/V/M % % Volume control damper in the entry spigot Measuring damper (only in combination with AR/S air exhaust round plenum box side entry spigot and A/S air exhaust square plenum box side entry spigot) Side entry spigot Vertical entry spigot Exhaust air square plenum box Supply air square plenum box Exhaust air round plenum box Supply air round plenum box Square diffuser plate, square nozzle arrangement central fastening Square diffuser plate, square nozzle arrangement fastening with four screws Square diffuser plate, radial nozzle arrangement central fastening Square diffuser plate, radial nozzle arrangement, fastening with four screws Circular diffuser plate, radial nozzle arrangement central fastening Fastening with four screw is recommended for size 600, 625. Versions KK4 and KR4 for dimensions 0, 0 and 0 are available only when ordering the diffuser plate without the plenum box.