Instruction Manual. Caravan Charging System CSV 404. Table of contents

Similar documents
Instruction Manual. Caravan Charging System CSV 414. Table of contents

Instruction manual. CSV 402 caravan power supply. Table of contents

Instruction Manual. Electrobloc EBL 40 B

Installation instructions. Adapter AD 01 AD 02 AD 03

Instruction manual. Electrobloc EBL 109-6

Instruction Manual. Electroblock EBL 119 EBL 119 with OVP. Table of contents

Operating Instructions

Instruction manual. Electrobloc EBL 269

Instruction manual. 0 manual for LT A control and switch panel. Table of contents

Instruction Manual. Control and Display Panel DT 220 C. Table of contents

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

Instruction manual. 0 Manual Control and Switch Panel DT 201 B. Table of contents

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7

TRADE PRODUCTS. Electronic systems for recreational vehicles Supplying controlling indicating

Wilo-Control SC-Fire Jockey

Operating Instruction Manual for Instrument Panel IT 992 Art.-Nr Page 1 / 5

User Manual Rittal PMC UPS 6kVA

MP V 8A Electronic Smart Charger. Instruction and Information Manual

GEIGER-GJ56.. with mechanical end stop For Venetian blinds and exterior blinds

GEIGER-GJ5610v1 with mechanical end stop For Venetian blinds and exterior blinds for 100 V power supply

PURE SINE WAVE DC TO AC POWER INVERTER

GEIGER GJ56.. AIR (GJ56.. F03) for Venetian blinds

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Installation manual wall-mounted distributor

Instruction Manual. Sewage lifting station compli 300

DC Master 24/ A

Cordless Floor Polisher

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

T35 W35. Thermoelectric cooler Instruction Manual 6. Thermoelektrische Kühlbox Bedienungsanleitung 16. Glacière thermoélectrique Notice d emploi 27

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

JANDS DD-8. Technical Manual. Version 1.0

OWNER S MANUAL MiniBoost

GEIGER-GJ56.. For Venetian blinds and exterior blinds

Cordless Floor Polisher

AXIAL FANS Axis / Tubo OPERATION MANUAL

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

User Manual TABLE MAGNIFIER TL-70. User-friendly Manual ID: #05007

GEIGER-SOLIDline* GEIGER-Touch (GU45..M) for rolling shutters, awnings and screens. Bedienungsanleitung. Operating Instructions. Manuel d utilisation

OPERATION MANUAL BATTERY CHARGER DFC-10P DFC-50P DFC-450P DFC-650P

C3 Operating Instructions

c-go 24V/6A 24V/8A 24V/12A

Smart 110 with built-in flashlight for 6 240Ah lead-acid batteries

Installation manual portable distributors

HST-BL-2830MS & HST-BL-2830MS-USA

MANUAL. Single charger

Instrucciones de instalación y funcionamiento Installation and operating instructions

M A N U A L. Field Current Controller F2.2

Domestic Water Supply Pressure Pumps

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

original operating manual Operating manual Translation of the Item-No.: ,

Operating Instructions

Compact System NRGS 11-2 NRGS Original Installation Instructions English

LCD video-goggle with 5,8 GHz diversity receiver HIVR 101

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

CoolFreeze CFX35, CFX40, CFX50, CFX65, CFX65DZ

Operating Instructions

Operating Manual COST CONTROL - POWER CONSUMPTION MONITOR

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

OPERATION & MAINTENANCE INSTRUCTIONS

BULK FOOD TROLLEY MODEL BFT-150-E

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS OWNER S MANUAL

Operator s and Maintenance Manual

KeContact P20. User manual

Battery Charger JCB-FCH12Li

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

DeltaSol AX * *

GEIGER-SoftPerfection (GR45..E03) for rolling shutters with stoppers and anti-lift device

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

BATTERY CHARGER-STARTER

Demco. Model E Bedienungsanleitung Instruction manual Mode d emploi Istruzioni d uso Instrucciones para el servicio Инструкция по эксплуатации

Micro Diaphragm Gas Sampling Pumps

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

Battery Charger JCB- SCH20LI.2

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

HST -LS Interlocking device (Translation of Original Manual)

HQ-INV300WU-12 HQ-INV300WU WATT DC TO AC MODIFIED SINEWAVE INVERTER WITH USB OUTPUT

Battery Charger JCB-FCH20LI2

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Installation and Operating Instructions Magnetic Vibrator MR 1

1-50 KVA SINGLE-PHASE SERVO REGULATOR INSTRUCTIONS FOR USE SERVO SINGLE-PHASE VOLTAGE REGULATOR

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

GEMÜ 205 Electrically operated solenoid valve

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2

OPERATING INSTRUCTION UPS PROTECT A. PROTECT A PROTECT A. 1400

1 Safety instructions. 2 Device components. Blinds Management Motor control insert Universal AC 230 V ~ Art. No. 232 ME. Operating instructions

Directions for use CK 125 C EC, CK 150 B EC, CK 160 B EC, CK 160 C EC CK 200 B EC, CK 250 B EC, CK 315 B EC, CK 315 C EC ENGLISH VERSION

Operating Instructions for Roll-Up Door Operators / MDF

Installation and Operating Instructions Electric Vibrators HV/VFL Series

1100W PORTABLE GENERATOR

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Information I Manuals I service. AIR premium x2. Operating Instructions _a I 03/2012

Transcription:

Instruction Manual Caravan Charging System CSV 404 Table of contents 1 Introduction... 2 2 Safety information... 2 2.1 Meaning of safety symbols... 2 2.2 General safety information... 2 3 Operation... 3 3.1 Starting up caravan power supply... 3 3.2 Switching on and off... 4 4 Application and function... 4 4.1 unctions... 5 5 Layout... 7 5.1 Operating faults... 7 6 Maintenance... 8 Appendix... 9 E Schaudt GmbH, Elektrotechnik und Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Tel. 49 7544 95770, ax 49 7544 957729, www.schaudt gmbh.de 905.056 BA / EN Date: 18.03.2014

1 Introduction This instruction manual contains important information for the safe operation of equipment supplied by Schaudt. Make sure you read and follow the safety instructions provided. The instruction manual should always be kept in the vehicle. All safety information must be passed on to other users. 2 Safety information 2.1 Meaning of the safety symbols DANGER! ailure to comply with this sign may result in danger to life or physical condition. WARNING! ailure to comply with this sign may result in injury. CAUTION! ailure to comply with the sign may result in damage to equipment or other connected loads. This symbol references recommendations or special features. 2.2 General safety instructions The design of the device is stateoftheart and complies with approved safety regulations. ailure to observe the safety instructions may nonetheless lead to injury or damage to the device. Only use the device when it is in perfect technical condition. Any faults affecting the safety of persons or the proper functioning of the device must be repaired immediately by specialists. DANGER! 230V units carrying mains voltage. Risk of fatal injury due to electric shock or fire: The motorhome or caravan s electrical system must comply with DIN, VDE and ISO regulations. Never try to modify the electrical system. Do not try to modify the device. Only qualified electricians are permitted to establish electrical connections in accordance with the installation instructions supplied by Schaudt. Connection work may only be carried out after the power has been disconnected. Never try to start the device using a defective mains cable or a faulty connection. Never undertake maintenance on the device when it is live. DANGER! Incorrect installation Electric shock or damage to connected devices: Install as shown in installation instructions. The mains connection line may only be replaced by an authorised customer service department or by those qualified. 2 Date: 18.03.2014 905.056 BA / EN

WARNING! Hot components Burns: Blown fuses may only be changed after the power to the system has been disconnected Blown fuses may only be replaced once the cause of the fault is known and has been rectified Never bypass or repair fuses The back of the device can get hot during operation. Do not touch them. Only use original fuses rated as specified on the device Never store heat sensitive objects close to the device (e.g. temperature sensitive clothes if the device has been installed in a wardrobe) 3 Operation This device is not intended to be used by persons (including children) with limited physical, sensory or mental aptitude or lack of experience and/or knowledge unless they are supervised by a person responsible for their safety or have received instruction from this person as to how the device is used. Children must be supervised to ensure they do not play with the device. This device is intended for installation into a vehicle. The caravan power supply is operated solely from the control and switch panel connected. No operation is required for the CSV 404 caravan power supply in everyday use. 3.1 Starting up the caravan power supply Generator operation and passenger vehicle ferries CAUTION! The caravan power supply, 12V consumers and connected devices can be damaged if the thresholds for the 230V supply are exceeded. So therefore: Do not connect a generator until it is running smoothly. It is essential that the generator conforms to the specifications of the mains supply. Do not connect the caravan power supply on car ferries with the onboard mains voltage (a nonproblematic mains voltage cannot always be guaranteed on car ferries). The use of an upstream overvoltage protection device is recommended. Operation on towing vehicle CAUTION! Switch off the ignition when the towing vehicle is parked (when the caravan is connected to the towing vehicle). Otherwise the starter battery of the towing vehicle will discharge. 905.056 BA / EN Date: 18.03.2014 3

3.2 Switching on and off Control and switch panels of type LT... are supplied with a separate operating manual (kept with the vehicle). Please refer to this manual for instructions on operation. Activating the 12V main switch (12V ON) on the operating panel connected enables/disables the following electrical circuits: Pos. Circuit use with 1 Circuit 1 15 A 2 Circuit 2 15 A 3 Circuit 3 15 A 4 Water pump 7.5A The following consumers (circuits) continue to be provided with continual power: Pos. Circuit use with 1 Awning light 2 TV 10 A 3 Res 4 Application and function Control and operator panel LT... Caravan power supply CSV 404 230V AC ig. 1 12V consumers Onboard power supply system Lighting Pump Heater etc. Starter battery Towing vehicle The CSV 404 caravan power supply is the central power supply unit for all 12V consumers in the caravan s electrical system. It is usually located in a cupboard or storage area and is accessible from the front in order to change fuses. The caravan power supply has been designed solely for connecting to a 12V onboard power supply. Connected devices can be supplied from the towing vehicle s battery if a mains supply is not available. Because the device provides a humfree, stabilised output voltage, sensitive consumers such as transistor lights and radios can be connected and powered. 4 Date: 18.03.2014 905.056 BA / EN

Modules Actuation Protective circuits Mains The CSV 404 caravan power supply contains: a 12V power pack a main switch relay to switch certain consumers on and off the complete 12V distribution system fuses for the 12V circuits A control panel (such as a LT 4XX) is connected for operation. Connections provided for: Operator and control panel lat vehicle fuses protect the various circuits. Excess temperature Overload Short circuit 230V AC 10%, 47 63 Hz sinusoidal, protection class I Current 12V outputs may only be loaded up to a maximum of 90% of the rated current of the associated fuse (see block diagram or nameplate). All consumers together may not exceed the following load: Mains operation: 32 A Operation with towing vehicle, ignition ON: 15 A 4.1 unctions 12V main switch The main 12V switch on the operator and control panel connected isolates certain 12V consumers from the voltage supply (see also Page 4). 9 10 11 13 Relay circuit 12V for ignition ON (connector no. 10) from terminal 15 Voltage when ignition ON 8 7 9 6 1 10 4 2 5 11 3 13 12 ig. 2 Connector for towing vehicle power socket or the Automatic shutoff and Towing vehicle battery standby current functions to be guaranteed in line with the following specifications, both the 13pin connector of the caravan, and the socket of the towing vehicle must be assigned as per EN 16481 (see ig. 2). Autom. switchoff Consumers are switched off (with the exception of these with a continual supply, see Page 4) when the caravan is hitched to the towing vehicle and the ignition is switched on (power on terminal 10 of trailer hitch TH). Consumers can be switched on again at any time (the automatic disconnector does not prevent this). 905.056 BA / EN Date: 18.03.2014 5

Towing vehiclebattery standby current Refrigerator controller No standby current when the towing vehicle ignition is O, plus power consumption of control electronics of refrigerator (see documentation from refrigerator manufacturer and other consumers with a continual supply, see Page 4); measurement taken when all consumers in the caravan are switched off. This output supplies the control electronics of a fridge: rom the towing vehicle s battery when the ignition is switched on rom the mains supply when it is connected up The refrigerator only operates on 12 V when the caravan is hitched to the towing vehicle and the ignition is switched on. Water pump The water pump is connected directly to the CSV 404. The supply voltage to the pump is enabled from the Pump switch on the operator and control panel. The switch of a water tap (or multiple taps connected in parallel) can be connected to the CSV 404 as an option (6.3mm blade terminal Water Tap and Water Tap Signal, instead of cable bridge). The pump is then switched on when the electric switch in the tap is closed by opening the tap. 6 Date: 18.03.2014 905.056 BA / EN

5 Layout 1 2 3 4 5 6 7 8 9 10 ig. 3 ront view of CSV 404 caravan power supply 1 2 3 4 5 Adhesive label for details Connector panel for TV, awning light, spare, water pump, water tap Adhesive label for functions Housing lat vehicle fuses 6 7 8 9 10 Connector panel for circuits 1 and 2, fridge controller Controller for operating and control panel Connector for refrigerator supply Trailer coupling connector plug Mains cable 5.1 aults lat vehicle fuses A fault in the power supply system is usually caused by a blown fuse. Please contact our customer service team if you cannot rectify the fault using the following table. 905.056 BA / EN Date: 18.03.2014 7

If this is not possible, e.g. if you are abroad, you can have the caravan power supply repaired at a specialist workshop. In this case, you must ensure that the warranty is not invalidated by incorrect repairs being carried out. Schaudt GmbH will not accept any liability for damage resulting from such repairs. ault Possible cause Remedy 12V supply does not work in the 12V main switch is switched off 12V main switch must be swit leisure area ched on Defective fuse or cabling Caravan power supply faulty Have the fuse and cabling chek ked Contact customer service Caravan power supply cannot Caravan power supply faulty Contact customer service be switched on from the control No supply voltage Check the battery or mains conpanel. nection Rocker switch is defective Contact customer service 12V supply from the towing ve Pin assignment of towing vehi Contact customer service hicle not working cle socket not complete or correct 6 Maintenance use in the towing vehicle defective or cabling incorrect Caravan power supply faulty The CSV 404 caravan power supply requires no maintenance. Have the fuse and cabling chek ked Contact customer service Clean the caravan power supply with a clean, slightly damp cloth and a mild detergent. Never use spirit, thinners or similar substances. Do not allow fluid to penetrate the inside of the caravan power supply. No part of this manual may be reproduced, translated or copied without express written permission. E No part of this manual may be reproduced, translated or copied without express written permission. 8 Date: 18.03.2014 905.056 BA / EN

Appendix A Ma B Customer service address Send in device C EC Declaration of Conformity Schaudt GmbH hereby confirms that the CSV 404 caravan power supply complies with the following relevant regulations. The original EC declaration of conformity is available for reference at any time. Schaudt GmbH, Elektrotechnik & Apparatebau Planckstraße 8 88677 Markdorf Germany Customer service Schaudt GmbH, Elektrotechnik & Apparatebau Planckstraße 8 D88677 Markdorf Phone: 49 7544 957716 Email: kundendienst@schaudtgmbh.de Web: www.schaudtgmbh.de Returning a faulty device: Always use wellpadded packaging. Complete and enclose the fault report, see Appendix C. Send it to the addressee (free delivery). ault report In the event of damage, please fill in the fault report and send it with the faulty device to the manufacturer. Device type: Item no.: Vehicle: Manufacturer: Model: Own installation? Yes No Upgrade? Yes No Upstream overvoltage protection? Yes No ollowing fault has occurred (please tick): Other comments: Electrical consumers do not work which? (please specify below) Switching on and off not possible Persistent fault Intermittent fault/loose contact 905.056 BA / EN Date: 18.03.2014 9

D Block diagram/wiring diagram A2 A1 * Trailer coupling assignment of towing vehicle / caravan connector to EN 1648 1. Connectors AHK 9 and AHK 10 must be fused externally in the vehicle with max. 15A. 6.3 x 0.8 3G1.5 L = 1.2m 230V~50Hz CSV 404 12.5V/32A Switch Mode A3 A11 A12 2.5A Polyswitch Auto. switchoff 15A AHK 10* AHK 11* 15A AHK9* AHK 13* ridge cartridge ridge controller MSQ/0 8 pin strip S CSV 403 2.5A Poly switch Jumpers 7.5A 1 1 12V O 2 2 3 3 4 4 5 5 6 6 7 8 7 8 12V On 12V indicator Mains indicator 12V nc Pump To the panel Pump WC 7A Polyswitch Water Tap Signal Ext. bridge Switching stage 15A 15A Water Tap Circuit 1 Circuit 2 15A 10A Circuit 3 Awning light TV Circuit 5 Spare Plug connector L PA 401 6.3 x 0.8 (32 way) 10 Date: 18.03.2014 905.056 BA / EN